Batignolles Technologies Thermiques Qatar

Road L, New Salwa Industrial Area


P.O Box 23794
Doha – Qatar
Tel: (974) 411 49 84
Fax: (974) 411 49 82

LOCAL POST WELD HEAT


TREATMENT
Client: Sewon

29/01/09 T. Samir 1
Scope of work

29/01/09 T. Samir 2
PWHT planning

29/01/09 T. Samir 3
Heating pads
calculation

Reference: CP10
Power: 2.7 Kw
Voltage: 60 V
Current: 45 Amp

29/01/09 T. Samir 4
Heating pads
calculation
• Drum outside diameter (O.D) =
2600 m
• Circumference = 2600*3.14=
8160 mm
• To cover the total circumference,
we need:
• 8160:260 = 31.38 means 32
heating pads
• Total pads required= Total area
to be covered/ width of electrical
29/01/09 pad T. Samir 5
Electrical power
calculation
• The power of 1 pad = 2.7kw
• Total power required =
2.7*256
= 692
Kw
Means 864 KVA

With a safety factor of


20%, we selected 2
29/01/09
generators with 500
T. Samir 6
Thermocouple location

29/01/09 T. Samir 7
Project
implementation

29/01/09 T. Samir 8
Project
implementation
1000
gallon
tank

29/01/09 T. Samir 9
Project
implementation
2*500 KVA
generators

29/01/09 T. Samir 10
Project
implementation
Electrical
Cables:
generator/
distribution
board

29/01/09 T. Samir 11
Project
implementation
Electrical
distribution
board

29/01/09 T. Samir 12
Project
implementation
Recorde
r
Heat
controll
er
Programm machin
er e

29/01/09 T. Samir 13
Project
implementation
Thermocoupl
e connation
to the
recorder &
programmer

29/01/09 T. Samir 14
Project
implementation

Power cable :
heating
machine to
the vessel

29/01/09 T. Samir 15
Project
implementation

29/01/09 T. Samir 16
Project
implementation

Chart of heat
treatment

29/01/09 T. Samir 17