Académique Documents
Professionnel Documents
Culture Documents
Appendix A to
PW6000 TEC ID CONE CAVITY CFD ANALYSES Memo
Geometry
Inlet6 Inlet5 Inlet4 Free Slip Outlet
Rotating wall 1
Rotating Wall
Static Wall
Note: Clearance at inlet1 is 35 mil under EIS Take Off condition. Clearance at inlet 1 is 17 mil under IDLE Condition. EIS Take Off Condition : Wall Temperature for Rotating wall & Static wall is 580.37 deg F. Wall Temperature for Rotating wall1 1531.08 deg F. IDLE Condition: Wall Temperature for Rotating wall & Static wall is 313.31 deg F. Wall Temperature for Rotating wall1 : 1158.6 deg F. .
Inlet1
Mass flow inlet 0.381 -430.37 0.5 3
Inlet2
Mass flow inlet 0.002 -430.37 1 3
Inlet3
Mass flow inlet 0.001 -430.37 -3
Inlet4
Mass flow inlet 0.156 -869.96 1 3
Inlet 6
Mass flow inlet 0.026 --1381.08 1 3
Outlet
Pressure Outlet -20.63 1208.96** ---
Inlet1
Mass flow inlet 0.044 -163.31 0.5 3
Inlet2
Mass flow inlet 0.0004 -163.31 1 3
Inlet3
Mass flow inlet 0.0002 -163.31 -3
Inlet4
Mass flow inlet 0.031 -428.19 1 3
Inlet 6
Mass flow inlet 0.005 --1008.60 1 3
Outlet
Pressure Outlet -14.88 986.69** ---
Contours of Stream Function Per Radian * 2 (lbm/s) EIS Take Off Condition
21.3 20.7
21.3
21.3
21.4
14.885
14.88
14.88
0.4 0.3
0.7
0.8
0.4 0.4 0.6 0.4 0.5 0.5 0.6 0.7 0.8 0.4
0.4
0.3
0.4
0.4 0.1
30 29 28
18
14
17 13 16 15 9 10 11 12
5 6
8 4 3 2
10
h (btu/hr-ft2-r)
Point ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
H2 (btu/hr-ft2-r) 104 90 92 100 111 119 89 54 89 6 36 51 34 40 44 51 50 48 47 51 47 51 44 47 60 42 27 156 126 96 101 124 124
11
25 20 15 10 5 0 0 5 10 15 Point ID 20 25 30 35
Point ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
R (in) 6.5662 6.6552 6.7005 6.7625 6.7625 6.7625 6.7625 6.7625 7.0097 7.0932 7.1250 7.1250 7.1748 7.3919 7.8361 8.5026 9.2146 9.9557 10.7455 11.5531 12.3307 12.7531 13.2229 13.4327 13.4874 13.3776 13.2500 13.3294 13.4394 13.5005 13.5250 13.5517 13.5640
H2 (btu/hrft2-r) 32 11 24 25 30 23 7 13 12 11 16 23 12 14 16 16 16 16 12 13 14 14 13 15 17 13 19 39 40 33 34 36 37
h (btu/hr-ft2-r)