Vous êtes sur la page 1sur 157

INSTALLATION GUIDELINES ALCPLUS2

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 1 of 157 Rev./Ver.

02

INDEX
1. INSTALLATION AND PROCEDURES FOR ENSURING THE ELECTROMAGNETIC COMPATIBILITY .................................................................... 5
1.1GENERAL INFORMATION TO BE READ BEFORE THE INSTALLATION .............................5 1.2GENERAL ...............................................................................................................................6 1.3MECHANICAL INSTALLATION.............................................................................................6
1.3.1 IDU installation ................................................................................................................ 6

1.4ELECTRICAL WIRING ...........................................................................................................7


1.4.1 Electrical characteristics ................................................................................................. 7

1.5CONNECTIONS TO THE SUPPLY MAINS ...........................................................................8 1.6IDU-ODU INTERCONNECTION CABLE ..............................................................................8


1.6.1 Connectors ........................................................................................................................ 8 1.6.2 Max length ........................................................................................................................ 8

1.7GROUNDING CONNECTION ................................................................................................8 1.8SURGE AND LIGHTNING PROTECTION ............................................................................9

2. ALCPLUS2 INDOOR UNIT CONNECTORS .............................................................. 11


2.1.1 ALCplus2 1+0/1+1 (GAI0157/GAI0152) ..................................................................... 11 2.1.2 ALCplus2 16E1 1+0/1+1 (GAI0155/GAI0156)........................................................... 11 2.1.3 ALCplus2 NODAL 1+0/1+1 (GAI0163/GAI0162)........................................................ 12 2.1.4 ALCplus2 32E1 1+0/1+1 (GAI0169/GAI0168) ........................................................... 12

3. INSTALLATION ONTO THE POLE OF THE ODUWITH SEPARATED ANTENNA..................................................................................................................... 22


3.1INSTALLATION KIT ..............................................................................................................22
3.1.1 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ................................................ 23

3.2INSTALLATION PROCEDURE ..............................................................................................23


3.2.1 1+0 version Installation onto the pole of the supporting plate ........................... 23 3.2.2 1+0 version Installation onto the pole of the supporting plate by Band-it ........ 24 3.2.3 1+1 version Installation onto the pole of the supporting plate ........................... 24 3.2.4 Installation of the ODU ................................................................................................... 24 3.2.5 GROUNDING ..................................................................................................................... 25

4. INSTALLATION ONTO THE WALL OF THE ODUWITH SEPARATED ANTENNA..................................................................................................................... 38


4.1INSTALLATION KIT ..............................................................................................................38
4.1.1 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ................................................ 38
REF :MN.00024.E 004
Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 2 of 157 Rev./Ver.

02

4.2INSTALLATION PROCEDURE ..............................................................................................38


4.2.1 1+0 version Installation onto the wall of the supporting plate ............................ 39 4.2.2 1+1 version Installation onto the wall of the supporting plate.............................. 39 4.2.3 Installation of the ODU ................................................................................................... 39 4.2.4 GROUNDING ..................................................................................................................... 40

5. INSTALLATION ONTO THE POLE OF THE ODUWITH INTEGRATED ANTENNA..................................................................................................................... 50


5.1FOREWORD ...........................................................................................................................50
5.1.1 INSTALLATION KIT .......................................................................................................... 50 5.1.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ................................................ 50

5.2INSTALLATION PROCEDURE ..............................................................................................51


5.2.1 Installation onto the pole of the support system and the antenna ......................... 51 5.2.2 Installation of ODU .......................................................................................................... 51 5.2.3 ODU installation ............................................................................................................... 52

5.3ANTENNA AIMING ................................................................................................................53 5.4COMPATIBILITY ....................................................................................................................53 5.5GROUNDING .........................................................................................................................53

6. INSTALLATION ONTO THE POLE OF THE ODUWITH INTEGRATED ANTENNA (KIT V32307,V32308, V32309) ........................................................... 69
6.1FOREWORD ...........................................................................................................................69
6.1.1 INSTALLATION KIT .......................................................................................................... 69 6.1.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ................................................ 69

6.2INSTALLATION PROCEDURE ..............................................................................................69


6.2.1 1+0 MOUNTING PROCEDURES ...................................................................................... 70 6.2.2 1+1 MOUNTING PROCEDURES ...................................................................................... 71

7. INSTALLATION ONTO THE POLE OF THE ODUWITH RFS INTEGRATED ANTENNA..................................................................................................................... 82


7.1FOREWORD ...........................................................................................................................82
7.1.1 INSTALLATION KIT .......................................................................................................... 82 7.1.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ................................................ 82

7.2INSTALLATION PROCEDURE ..............................................................................................82


7.2.1 1+0 MOUNTING PROCEDURES ...................................................................................... 83 7.2.2 1+1 MOUNTING PROCEDURES ...................................................................................... 84

8. INSTALLATION ONTO THE POLE OF ODU ASNWITH STANDARD LOCK ......... 94


8.1ODU COUPLING KIT ............................................................................................................94
8.1.1 ODU AS .............................................................................................................................. 94

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 3 of 157 Rev./Ver.

02

8.1.2 ODU ASN ........................................................................................................................... 94

8.2INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ............................95


8.2.1 ODU AS and ODU ASN (Fast Lock) ............................................................................... 95 8.2.2 ODU ASN (Standard Lock).............................................................................................. 95

8.3INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ..............................96


8.3.1 ODU AS and ODU ASN (Fast Lock) ............................................................................... 96 8.3.2 ODU ASN (Standard Lock).............................................................................................. 96

9. GENERAL INSTALLATION ......................................................................................... 106


9.1RG8 Cable Runway ................................................................................................................106 9.2Outdoor Grounding .............................................................................................................107 9.3Indoor Installation ...............................................................................................................108 9.4Outdoor Installation..................................................................................................................114

10.0 LABELING..................................................................................... ............................ 117


10.1Labeling Tools .......................................................................................................................117 10.2Indoor Labeling ......................................................................................................................118 10.3Outdoor labeling ....................................................................................................................125

11.0INSTALLATION PICTURE ......................................................................................... 127


12.0SITE WORKS .................................................................................................................. ...129 13.0STANDARD PROCEDURE INSTALLATION........................................................................ 14.0INSTALLATION OF DCPDB............................................................................................ 141 144

15.0RG CABLE CHARACTERISTIC......................................................................................... 146 16.0DESIGN LOADING AND STANDARDS............................................................................ 150

17.0BOOM/BRACKET DETAILS AND STANDARDS................................................................. 150 18.0FABRICATION.............................................................................................................. ..... 150 19.0IF PANEL PLATE...................................................................................................... ......... 155 20.0IMPEDANCE AT CELL...................................................................................................... 157 21.0SURGE ARRESTOR.......................................................................................................... 157

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 4 of 157 Rev./Ver.

02

1. INSTALLATION AND PROCEDURES FOR ENSURING THE ELECTROMAGNETIC COMPATIBILITY

1.1GENERAL INFORMATION TO BE READ BEFORE THE INSTALLATION


The equipment is a split mount (indoor-outdoor) radio link system operating in the frequency ranges 4, 6, 7, 8, 13, 15, 18, 23, 25, 28 and 38 GHz, for low, medium and high transport capacity (from 4 up to 622 Mbit/s), designed to establish LAN-LAN connections and PDH/SDH access. For the details related to the actual used frequency band refer to the label on the equipment. The system is provided with an integral antenna; however, in case its antenna is not used, it should be connected to an antenna conforming to the requirements of ETSI EN 302 217-4-2 for the relevant frequency band. The equipment is composed by the following separate units: radio unit (outdoor) with or without integral antenna Baseband (indoor)

This equipment makes use of non-harmonized frequency bands. Class 2 radio equipment subject to Authorisation of use. The equipment can operate only at the frequencies authorised by the relevant National Authority. The deployment and use of this equipment shall be made in agreement with the national regulation for the Protection from Exposure to Electromagnetic Field. The symbol

indicates that, within the European Union, the product is subject to separate collection at the product endof-life. Do not dispose of these products as unsorted municipal waste. For more information, please contact the relevant supplier for verifying the procedure of correct disposal.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 5 of 157 Rev./Ver.

02

1.2GENERAL
The equipment consists of IDU and ODU(s) units and is mechanically made up of a wired 19 subrack (IDU) and a weather proof metallic container (ODU). The two units are shipped together in an appropriate cardboard box. After unpacking, mechanical installation takes place followed by electrical connections as described in the following paragraphs.

1.3MECHANICAL INSTALLATION
IDU
The IDU (all the versions) is made up of a metallic box with two little lateral brackets (90 bent), provided with two holes for M6 screws (2 screws for each side), to fasten the unit to a 19 rack or to a 19 mechanical structure.

1.3.1IDU installation
In order to avoid damage to the cables connected on the front panel of the IDU, the two lateral brackets (90 bent) can be positioned on the IDU lateral panel in three different position, by means of 3 phillips screws. ALPlus2 - To avoid overtemperature problems the free space below and above an IDU must be 22 mm (1/2RU) minimum. ALCPlus2 - IDUs can be stacked.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 6 of 157 Rev./Ver.

02

1.4ELECTRICAL WIRING
The electrical wiring must be done using appropriate cables thus assuring the equipment responds to the electromagnetic compatibility standards. The cable terminates to flying connectors which have to be connected to the corresponding connectors on the equipment front. Position and pinout of the equipment connectors are available in this section. Tab.10 shows the characteristics of the cables to be used and the flying connector types.

Interconnecting points Battery Tributary signals

Type of connector terminating the cable Polarized SUBD 3W3 female connector SCSI 50 pin male connector Female type D connector with 9 pins and shielded holder USB B RJ45 Plug-in Plug-in RJ45 Female type D connector with 9 pins and shielded holder Faston male type

User input/alarm output LCT NBUS STM1 Optical LAN port Electrical LAN port RS232 GND

Type of cable/conductor Section of each wire 2.5 sq.mm a 8 conductor cable different for 75 Ohm and 120 Ohm signals 9 conductor cable with double brass sheath type interconductor DB28.25 or equivalent Standard printer cable
b

SIAE code F03580 and F03581 Relevant to plug-in module Relevant to plug-in module Standard CAT5e cable 9 conductor cable with double brass sheath type interconductor DB 28.10 or equivalent Section area 6 sq. mm.

a. For power cable length longer than 20 m. a section of 4 mm is required. b. Max length 2.5 m Tab.10 - Characteristics of the cables

1.4.1Electrical characteristics
-Cable type -Cable impedance - Insertion loss -Return loss (connectors included) - Max total DC resistance -Shielding effectiveness coaxial 50 ohm 24 dB at 330 MHz batter than 22 dB (from 100 MHz to 400 MHz) 4 Ohm 90 dB

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 7 of 157 Rev./Ver.

02

1.5CONNECTIONS TO THE SUPPLY MAINS


During the final installation, the IDU must be protected by a magneto-thermal switch (not supplied with the equipment), whose characteristics must comply with the laws in force in one's country. The disconnection from the supply mains is made disconnecting the connector SUB-D 3W3 from the IDU.

1.6IDU-ODU INTERCONNECTION CABLE


1.6.1Connectors
N-type male connectors on both sides.

1.6.2Max length
With the 1/4 cable, the max length is 300m for all modulation profile

1.7GROUNDING CONNECTION

Fig.36 and annexed legend show how to perform the grounding connections.

Legend
1 2 3 4 5 6 7 IDU grounding point, faston type. The cross section area of the cable used must be 4 sq. mm. The faston is available on the IDU both sides. ODU grounding bolt. The cross section area of the cable used must be 16 sq. mm IDUODU interconnection cable type Celflex CUH 1/4 terminated with Ntype male connectors at both sides. Grounding kit type Cabel Metal or similar to connect the shield of interconnection cable. Matching cable (tail) terminated with SMA male and N female connectors. Battery grounding point of IDU to be connected to earth by means of a cable with a section area 2.5 sq. mm. Length 10 m. Grounding cords connected to a real earth internal of station. The cross section area of the cable must be 16 sq. mm Fig.36 - Grounding connection

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 8 of 157 Rev./Ver.

02

1.8SURGE AND LIGHTNING PROTECTION


Gas dischargers are present both in IDU and ODU.

Characteristics
-DC spark-over voltage 150V 20% -Nominal impulse discharge current (wave 8/20 ms) 20kA -Single impulse discharge current /wave 8/20 ms) 25kA -Performances in accordance to EN 301 489.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 9 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 10 of 157 Rev./Ver.

02

2.

ALCPLUS2 INDOOR UNIT CONNECTORS

IDU FRONT PANEL


The front panel of the ALCplus2 IDU is made up by various connectors depending on IDU version: in the following type of connectors and relevant pin-out are listed. On the body of each IDU there is the ground connection: 6.3mm male (Faston).

2.1.1ALCplus2 1+0/1+1 (GAI0157/GAI0152)


In Fig.8 and Fig.9 are shown the 1+0 and 1+1 version. The following connectors are available: MNGT1, 2 management Port MNGT 1, 2 set MDI or MDIX status automatically

LAN port 1, 2, 3, 4 electrical 10/100/1000BaseT Electrical port 1, 2, 3, 4 can be configured MDI or MDIX via WEBLCT LAN port 3, 4 100/1000BaseX Trib A, B LCT, management USER IN/OUT Connector for 50 Ohm interconnection to ODU 1 connector 1+0, 2 connectors in 1+1 (Fig.2)

-48 Vdc power supply 1 connector in 1+0, 2 connectors in 1+1 In 1+1 the two power supply connectors are in parallel (Fig.1)

2.1.2ALCplus2 16E1 1+0/1+1 (GAI0155/GAI0156)


In Fig.10 and Fig.11 are shown the 1+0 and 1+1 version. The following connectors are presents: MNGT1, 2 management Port MNGT 1, 2 set MDI or MDIX status automatically

LAN port 1, 2, 3, 4 electrical 10/100/1000BaseT Electrical port 1, 2, 3, 4 can be configured DI or MDIX via WEBLCT LAN port 3, 4 100/1000BaseX Trib A, B LCT, management USER IN/OUT Trib 1/8, 9/16 E1, 75 Ohm and 120 Ohm interfaces are present in the same connectors (different pins) Connector for 50 Ohm interconnection to ODU 1 connector 1+0, 2 connectors in 1+1 (Fig.2) -48 Vdc power supply 1 connector in 1+0, 2 connectors in 1+1(Fig.1)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 11 of 157 Rev./Ver.

02

2.1.3ALCplus2 NODAL 1+0/1+1 (GAI0163/GAI0162)


STM-1 1, 2 in/out SFP can be I.1, S1.1, L1.1, L1.2, electrical coaxial 1.0/2.3 SFP LAN port 3, 4 100/1000BaseX SFP-LC Trib A, B RJ45 (Tab.19) N-BUS 1, 2 connection among IDUs only through SIAE cable F03471 LCT, management USB type B (receptable) USER IN/OUT SUB-D male 9 pin (Tab.20)

Trib 1/8, 9/16 E1, 75 Ohm and 120 Ohm interfaces are present in the same connectors (different pins) 50 pin SCSI female (Tab.12 for 75 Ohm and Tab.13 for 120 Ohm) Connector for 50 Ohm interconnection to ODU 1 connector 1+0, 2 connectors in 1+1 SMA (Fig.2)
1

-48 Vdc power supply 1 connector in 1+0, 2 connectors in 1+1 SUB-D 3W3 (pinout on the panel) (Fig.1)

2.1.4 ALCplus2 32E1 1+0/1+1 (GAI0169/GAI0168)


In Fig.12 and Fig.13 are shown the 1+0 and 1+1 version. The following connectors are present: MNGT1, 2 management Port MNGT 1, 2 set MDI or MDIX status automatically RJ45 (Tab.16)

LAN port 1, 2, 3, 4 electrical 10/100/1000BaseT Electrical port 1, 2, 3, 4 can be configured MDI or MDIX via WEBLCT RJ45 (Tab.11) STM-1 1, 2 in/out SFP can be I.1, S1.1, L1.1, L1.2, electrical coaxial 1.0/2.3 SFP LAN port 3, 4 100/1000BaseX SFP-LC Trib A, B RJ45 (Tab.19) N-BUS 1, 2 connection among IDUs only through SIAE cable F03471 LCT, management USB type B (receptable)

USER IN/OUT SUB-D male 9 pin (Tab.20) Trib 1/8, 25/32 E1, 75 Ohm and 120 Ohm interfaces are present in the same connectors (different pins) 50 pin SCSI female (Tab.12 for 75 Ohm and Tab.13 for 120 Ohm) Connector for 50 Ohm interconnection to ODU 1 connector 1+0, 2 connectors in 1+1 SMA 1 -48 Vdc power supply 1 connector in 1+0, 2 connectors in 1+1 SUB-D 3W3 (pinout on the panel)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 12 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 13 of 157 Rev./Ver.

02

LAN2

LAN4

LAN1

LAN3

Pin RJ45 1 2 3 4 5 6 7 8

Function 10/100BaseT Twisted pair IN_P Twisted pair IN_N Twisted pair OUT_P nc nc Twisted pair OUT_N nc nc Tab.11 -10/100/1000BaseT, RJ45 1000BaseT BI_DB+ BI_DB BI_DA+ BI_DD+ BI_DD BI_DA BI_DC+ BI_DC

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 14 of 157 Rev./Ver.

02

Pin 75 Ohm 48 Ground A 23 Tributary 1/9 input 50 Ground A 25 Tributary 1/9 output 47 Ground A 22 Tributary 2/10 input 45 Ground A 20 Tributary 2/10 output 42 Ground A 17 Tributary 3/11 input 43 Ground A 18 Tributary 3/11 output 40 Ground A 15 Tributary 4/12 input 39 Ground A 14 Tributary 4/12 output 36 Ground B 11 Tributary 5/13 input 37 Ground B 12 Tributary 5/13 output 34 Ground B 9 Tributary 6/14 input 33 Ground B 8 Tributary 6/14 output 29 Ground B 4 Tributary 7/15 input 31 Ground B 6 Tributary 7/15 output 28 Ground B 3 Tributary 8/16 input 26 Ground B 1 Tributary 8/16 output Note: Join pin 44 with ground A pins, join pin 32 with ground B pins. Tab.12 - 8xE1, 50 pin SCSI female 75 Ohm

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 15 of 157 Rev./Ver.

02

Pin 49 23 44 24 25 44 21 22 44 46 20 44 16 17 44 19 18 44 41 15 44 13 14 44 10 11 32 38 12 32 35 9 32 7 8 32

120 Ohm Tributary 1/9 input Tributary 1/9 input Ground A Tributary 1/9 output Tributary 1/9 output Ground A Tributary 2/10 input Tributary 2/10 input Ground A Tributary 2/10 output Tributary 2/10 output Ground A Tributary 3/11 input Tributary 3/11 input Ground A Tributary 3/11 output Tributary 3/11 output Ground A Tributary 4/12 input Tributary 4/12 input Ground A Tributary 4/12 output Tributary 4/12 output Ground A Tributary 5/13 input Tributary 5/13 input Ground B Tributary 5/13 output Tributary 5/13 output Ground B Tributary 6/14 input Tributary 6/14 input Ground B Tributary 6/14 output Tributary 6/14 output Ground B

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 16 of 157 Rev./Ver.

02

5 4 32 30 6 32 27 3 32 2 1 32 Tab.13 - 8xE1, 50 pin SCSI

Tributary 7/15 input Tributary 7/15 input Ground B Tributary 7/15 output Tributary 7/15 output Ground B Tributary 8/16 input Tributary 8/16 input Ground B Tributary 8/16output Tributary 8/16 output Ground B female 120 Ohm)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 17 of 157 Rev./Ver.

02

Pin 1 2 3 4 5 6 7 8 9

Description C relay contact- branch 1 NA/NC relay contact - branch 1 C relay contact - branch 2 NA/NC relay contact - branch 2 User input 01 User input 02 User input 03 User input 04 Ground

Tab.15 - SUB-D 9 pin male USER IN/OUT)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 18 of 157 Rev./Ver.

02

MNGT2

MNGT1

Pin 1 2 3 4 5 6 7 8

Description Tx+ Tx Rx+ Rx -

Tab.16 - MNGT/1 and MNGT/2 100BaseT connector pin-out for 10/100BaseT Ethernet connection (RJ45)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 19 of 157 Rev./Ver.

02

Trib A

Trib B

Pin Description 1 Tx-C (IN) common 2 TX-F (IN) 120 Ohm 3 GND 4 TX-F (IN) 75 Ohm 5 Rx-C (OUT) common 6 Rx-F (OUT) 120 Ohm 7 GND 8 Rx-F (OUT) 75 Ohm Tab.18 - 2 Mbit/s wayside connector pin-out (RJ45)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 20 of 157 Rev./Ver.

02

RT1

RT2

Fig2. ODU Connectoions (Connector coax type SMA)

Fig1. IDU Power Connectors

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 21 of 157 Rev./Ver.

02

3. INSTALLATION ONTO THE POLE OF THE ODUWITH SEPARATED ANTENNA

3.1INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions: 1+0 version - antisliding strip (see Fig.40) - supporting plate plus 60114 mm pole fixing bracket and relevant nuts and bolts (see Fig.41) - adapting tools and relevant bolts and nuts for 219 mm pole (see Fig.42) - Band-it fixing system (see Fig.45) - antenna side flange, variable as function of RF frequency (see Fig.43) - support with ODU fast locking mechanism (see Fig.41) - connection to the antenna with flexible wave guide and possible use of a rigid elbow (optional) (see Fig.43) - kit for ground connection making part of ODU 1+0 version (6 GHz only) Besides the previous items a specific flange adaptor (kit V32409) must be used (see Fig.51). The flange is UDR70. 1+1 version - antisliding strip (see Fig.40) - supporting plate plus pole fixing bracket and relevant nuts and bolts (see Fig.41) - adapting tools and relevant bolts and nuts for 219 mm pole (see Fig.42) - hybrid with ODU fast locking mechanism (see Fig.44) - flexible waveguide trunk for connection to antenna (optional) (see Fig.43) - kit for ground connection making part of the two ODUs. 1+1 version (6 GHz only) Besides the previous items a specific flange adaptor (kit V32415) must be used (see Fig.52). The flange is UDR70. Warning: in order to avoid damages to flexible waveguides, dont fold or twist them more than values specified as limit in installation instructions of the waveguide supplier. In case of flexible wave guide use, Tab.23 shows the maximum bending radius.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 22 of 157 Rev./Ver.

02

3.1.1REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 N.1 N.1 N.1 13mm torque wrench 15 mm torque wrench 17 mm torque wrench 3 mm Allen wrench

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step.

3.2INSTALLATION PROCEDURE
Installation procedure proceeds according to the following steps: Version 1+0: installation onto the pole of the supporting plate 2 Version 1+0: installation onto the pole of the support plate by Band-it Version 1+1: installation onto the pole of the supporting plate 2 Installation of the ODU (common to both 1+0 and 1+1 version) ODU grounding

3.2.11+0 version Installation onto the pole of the supporting plate


Fig.40 Mount antislide strip around the pole. The position of the plastic blocks depends on the position of the supporting plate (see next step) Fig.41 Adhere the supporting plate to the antisliding strip plastic blocks and then secure it to the pole through the fixing bracket for 60114 mm pole (see Fig.41). Bolts and nuts are available on the supporting plate. Tightening torque must be 32 Nm.

Warning: As shown in Fig.42 an adapting kit must be used for the 219 mm pole. It consists of an additional plate to enlarge the standard supporting plate dimension and relevant Ubolt for 219 mm pole fixing. Fig.43 Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Fig.43 Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can be mounted horizontally (as shown in Fig.43) or vertically as function of convenience. Fig.44 Fix the support with ODU fast locking mechanism to the supporting plate making use of available bolts and nuts. Fig.44 shows the possible positions. Tightening torque must be 18 Nm. 2 In case of 219 mm pole, an adapting kit is supplied for the purpose.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 23 of 157 Rev./Ver.

02

3.2.21+0 version Installation onto the pole of the supporting plate by Band-it
In case of 1+0 ODU installation, a Band-it pole mounting kit can be used: through slots (see Fig.45) on the supporting plate two metallic bands secure the plate on the pole. Band characteristics are: thickness 0.76 mm width 19 mm. It is also possible to use the anti-sliding system (optional).

3.2.31+1 version Installation onto the pole of the supporting plate


Fig.40 Mount antislide strip around the pole. The position of the plastic blocks depends on the position of the supporting plate (see next step) Fig.41 Position the supporting plate to the antisliding strip plastic blocks and then secure it to the pole through the fixing bracket for 60114 mm pole (see Fig.41). Bolts and nuts are available on the supporting plate kit. Tightening torque must be 32 Nm. Fig.46 Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nuts available on the support plate. Tightening torque must be 18 Nm. Remove the plastic cover from the hybrid flange sides. Warning: Do not remove the foil from the hybrid flange sides. Fig.46 Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flange as shown in Fig.49. This avoids possible condensate to be channelled towards the ODU flange.

3.2.4Installation of the ODU


1 Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to the Oring of Fig.48. Warning: Do not remove the foil from the flange. 2 Bring the ODU with the two hands and position the ODU handle at the bottom side. 3 Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (see Fig.48) to antenna side flange (see Fig.43 1+0 version) or hybrid side flange (see Fig.46 1+1 version).

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 24 of 157 Rev./Ver.

02

Note: For 1+0 version the ODU can assume positions of Fig.47 depending on the polarisation. 4 With respect to the flange alignment, turn the ODU body approx. 30 anticlockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig.43 1+0 version or Fig.46 1+1 version) and ODU body reference tooth (see detail Fig.48) 5 When alignment is achieved, turn the ODU body clockwise until clack is heard and the ODU rotation stops. 6 Secure ODU body on the support by tightening bolts (1) (see Fig.43 1+0 version or Fig.46 1+1 version). Tightening torque must be 6 Nm. Final assembly of 1+1 version is shown in Fig.49. A parasol mounting is optionally possible.

3.2.5GROUNDING
The ODU must be connected to ground making reference to details of Fig.50.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 25 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 26 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 27 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 28 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 29 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 30 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 31 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 32 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 33 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 34 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 35 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 36 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 37 of 157 Rev./Ver.

02

4. INSTALLATION ONTO THE WALL OF THE ODUWITH SEPARATED ANTENNA

4.1INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions: 1+0 version - wall supporting plate with additional contact surface extension plates (see Fig.53) - antenna side flange, variable as function of RF frequency (see Fig.54) - support with ODU fast locking mechanism (see Fig.54) - connection to the antenna with flexible wave guide and possible use of a rigid elbow (optional) (see Fig.54) - kit for ground connection making part of ODU 1+0 version (6 GHz only) Besides the previous items a specific flange adaptor (kit V32409) must be used (see Fig.61). The flange is UDR70. 1+1 version - supporting plate with additional contact surface extension tools (see Fig.53) - hybrid with ODU fast locking mechanism (see Fig.56) - connection to the antenna with flexible wave guide and possible use of a rigid elbow (optional) (see Fig.54) - kit for ground connection making part of the two ODUs. 1+1 version (6 GHz only) Besides the previous items a specific flange adaptor (kit V32415) must be used (see Fig.62). The flange is UDR70. In case of flexible wave guide use, Tab.26 shows the maximum bending radius.

4.1.1REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 N.1 N.1 N.1 13mm torque wrench 15 mm torque wrench 17 mm torque wrench 3 mm allen wrench.

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step.

4.2INSTALLATION PROCEDURE
Installation procedure proceeds according to the following steps: version 1+0: installation onto the wall of the supporting plate version 1+1: installation onto the wall of the supporting plate installation of the ODU (common to both 1+0 and 1+1 version) ODU grounding.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 38 of 157 Rev./Ver.

02

4.2.11+0 version Installation onto the wall of the supporting plate


Fig.53 Fix on the supporting plate the two supplied extension plates to increase the wall contact surface. Fig.53 Secure the supporting plate on the wall using the more suitable screws. Fig.54 Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Fig.54 Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can be mounted horizontally (as shown in Fig.54) or vertically as function of convenience. Fig.55 Fix the support with ODU fast locking mechanism to the supporting plate making use of available bolts and nuts. Fig.55 shows three possible positions. Tightening torque must be 18 Nm.

4.2.21+1 version Installation onto the wall of the supporting plate


Fig.53 Fix on the supporting plate the two supplied extension plates to increase the wall contact surface. Fig.53 Secure the supporting plate on the wall using the more suitable screws. Fig.56 Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nuts available on the support plate. Tightening torque must be 18 Nm. Remove the plastic cover from the hybrid flange sides. Warning: Do not remove the foil from the hybrid flange sides. Fig.56 Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions of which depend on the waveguide type. Tighten progressively and alternatively the four screws with the following torque:

Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flange as shown in Fig.59 This avoids possible condensate to be channelled towards the ODU flange.

4.2.3Installation of the ODU


1 Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to the Oring of Fig.58. Warning: Do not remove the foil from the flange. 2 Bring the ODU with the two hands and position the ODU handle at the bottom side. 3 Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (see Fig.58) to antenna side flange (see Fig.54 1+0 version) or hybrid side flange (see Fig.56 1+1 version).

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 39 of 157 Rev./Ver.

02

Note: For 1+0 version the ODU can assume positions of Fig.57 depending on the polarisation. 4 With respect to the flange alignment, turn the ODU body approx. 30 anticlockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig.54 1+0 version or Fig.56 1+1 version) and ODU body reference tooth (see detail Fig.58) 5 When alignment is achieved, turn the ODU body clockwise until clack is heard and the ODU rotation stops. 6 Secure ODU body on the support by tightening bolts (1) (see Fig.54 1+0 version or Fig.56 1+1 version). Tightening torque must be 6 Nm. Final assembly of 1+1 version is shown in Fig.59. A parasol mounting is optionally possible.

4.2.4GROUNDING
The ODU must be connected to ground making reference to details of Fig.60.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 40 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 41 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 42 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 43 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 44 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 45 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 46 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 47 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 48 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 49 of 157 Rev./Ver.

02

5. INSTALLATION ONTO THE POLE OF THE ODUWITH INTEGRATED ANTENNA

5.1FOREWORD
The installation onto the pole of the ODU with integrated antenna concerns both 1+0 and 1+1 versions.

5.1.1INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions:

1+0 version

60 to 114 mm pole mounting kit consisting of: - centring ring and relevant screws (see Fig.63) - antislide strip (see Fig.64) - pole support system and pole fixing brackets (see Fig.65) - ODU with Oring and devices for ground connection

1+1 version
pole mounting kit from 60 to 114 mm for 1+1 consisting of: - centring ring and relevant screws (see Fig.63) - antislide strip (see Fig.64) - pole support system and pole fixing brackets (see Fig.65) hybrid mechanical body (see Fig.74) polarization twist disk (see Fig.76) 2 ODUs with Orings and devices for ground connection.

5.1.2REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.2 N.1 N.1 N.1 13 mm torque wrench 15 mm torque wrench 17 mm torque wrench 3 mm allen wrench.

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 50 of 157 Rev./Ver.

02

5.2INSTALLATION PROCEDURE
Installation procedure proceeds according with the following steps:

1+0 version
1 2 3 4 5

installation onto the pole of the support system installation of the antenna installation of ODU antenna aiming ODU grounding

1+1 version
1 2 3 4 5 6

installation onto the pole of the support system installation of the antenna installation of hybrid circuit installation of the two ODUs antenna aiming ODU grounding.

5.2.1Installation onto the pole of the support system and the antenna
Fig.63 Set the antenna in such a position as to be able to operate on its rear side. Locate the five threaded holes around antenna flange. Mount centring ring onto antenna flange and tight it with 3 calibrated bolts. Caution: centring ring should be mounted so that the screws do not stick out. Define if the antenna will be mounted with vertical or horizontal polarization. Check that free drain holes stay at bottom side. Mount bolt type M10x30, in position A leaving it loose of 2 cm approx. With horizontal polarization mount bolt type M10x30 in position D, leaving it loose of 2 cm approx. Fig.64 Mount antislide strip onto the pole. Place blocks as in Fig.64 following antenna aiming direction. Tighten the strip with screwdriver. Fig.65 Mount pole supporting system with relevant pole fixing brackets following antenna aiming direction as indicated by arrow. Antislide strip should result at the centre of supporting plate. Supporting system should lean against antislide clamp with the tooth as in Fig.66. Position the antenna in such a way that bolt in position A or D of Fig.63 cross through hole E of Fig.67. Secure the support system to the pole by means of the pole fixing brackets and relevant fixing bolts. Fig.68 Rotate the antenna body until the remainder three antenna holes coincide with the three support holes. Secure the antenna to the support by thightening the relevant passing through bolts.

5.2.2Installation of ODU
1+0 version
1 Apply silicon grease e.g. RHODOSIL PATE 4 to the Oring (4) of Fig.71 by protecting finger hands with gloves. 2 Bring the ODU with the two hands and position the ODU handle at the bottom side. The ODU handle can assume position of Fig.69 depending on the polarization. 3 Position the ODU body near the support system and align ODU side flange to antenna side flange (see Fig.70). With respect to the flange alignment, turn the ODU body approx. 30 anticlockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig.70) and ODU body reference tooth (see detail of Fig.71). 4 When alignment is achieved, turn the ODU body clockwise until clack is heard and the ODU rotation stops.Fig.72 and Fig.73 show ODU housing final position for vertical and horizontal polarization respectively. 5 Secure ODU body on the support system by tightening bolts (1) of Fig.70.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 51 of 157 Rev./Ver.

02

1+1 version

Fig.74 Apply silicon grease, type RHODOSIL PATE 4 to Orings (1). Insert Orings (1) and (6) into twist polarization disk (2). Vertical polarization Fix the disk on hybrid flange placing marker (4), on disk, close to V mark. Horizontal polarization Fix the disk on hybrid flange placing reference (4), on disk, close to H mark. In 13 GHz and 15 GHz ODUs the polarization disk is fixed to the hybrid flange by means of 3 screws as shown in Fig.75. Caution: Twist disk has two planes. Take care of position marker (4) on twist disk. The position of marker (4) plane should be in contact to hybrid like in figure. Tighten progressively and alternatively screws (7) with the same number of spring washers (8) with the following torque:

Fig.76 Fix hybrid to support system with four bolts (1) taking care of RT1/RT2 position shown by labels of Fig.76. Tighten progressively and alternatively four bolts (1).

5.2.3ODU installation
The installation procedure of the two ODUs is the same. 1 Apply silicon grease e.g. RHODOSIL PATE 4 to the Oring (4) of the Fig.71 by protecting finger hands with gloves. 2 Bring the ODU with the two hands and position the ODU handle at the bottom side. For 1+0 the ODU can assume position of Fig.69 depending on the polarisation. For 1+1 the handle ODU position is always placed at the right side (horizontal polarization). 3 Position the ODU body near the support system and align ODU side flange to antenna side flange (see Fig.70). With respect to the flange alignment, turn the ODU body approx. 30 anticlockwise and then insert the ODU body into the support and search for alignment between reference tooth on the support (see Fig.70) and ODU body reference tooth (see detail of Fig.71). 4 When alignment is achieved, turn the ODU body clockwise until clack is heard and the ODU rotation stops.Fig.72 and Fig.73 show ODU housing final position for vertical and horizontal polarization respectively for 1+0 version.Fig.77 shows ODU housing final position for 1+1 version. 5 Secure ODU body on the support system by tightening bolts (1) of Fig.70.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 52 of 157 Rev./Ver.

02

5.3ANTENNA AIMING
Antenna aiming for 1+0 version and 1+1 version is the same. The antenna aiming devices allow to perform the following adjustments with respect to the starting aiming position: - Horizontal 15 operating on the nut (3) shown in Fig.78, only after having loosen the nuts (7), (8), (9), (10) of Fig.79. - vertical 15 operating on vertical adjustment worm screw (2) shown in Fig.78 only after having loosen nuts (1), (2), (11) of Fig.79 and (4) and (5) of Fig.78. For adjustment from 0 to +30 extract nut (1) Fig.79 and position it in hole (4), extract nut (2) Fig.79 and position it in hole (6). Operate on vertical adjustment worm screw (2) after having loosen nuts (1), (2), (11) of Fig.79 and (4) of Fig.78. For adjustment from 0 to 30 extract nut (1) of Fig.79 and position it in hole (3), extract nut (2) of Fig.79 and position it in hole (5). Operate on vertical adjustment worm screw (2) after having loosen nuts (1), (2), (11) of Fig.79 and (4) of Fig.78. For vertical adjustment some markers, every 10, are available on support. The bigger marker gives 0 starting aiming position. Once the optimum aiming position is obtained, tighten firmly the four nuts (1), (2), (11) of Fig.79 and (4) and (5) of Fig.78 for vertical adjustment and the four nuts (7), (8), (9), (10) of Fig.79 for horizontal adjustment. Tighten with 15 mm wrench and 32 Nm torque.

5.4COMPATIBILITY
The pole installation kit of the ODU unit in 1+0 and 1+1 configuration is compatible with integrated antenna complying with SIAE standard with measures 0.2 m, 0.4 m, 0.6 m, 0.8 m of diameter.

5.5GROUNDING
See Fig.80. On ODU grounding can be connected with the available bolt spring washer and flat washers as shown.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 53 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 54 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 55 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 56 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 57 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 58 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 59 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 60 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 61 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 62 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 63 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 64 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 65 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 66 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 67 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 68 of 157 Rev./Ver.

02

6. INSTALLATION ONTO THE POLE OF THE ODUWITH INTEGRATED ANTENNA (KIT V32307,V32308, V32309)
6.1FOREWORD
The description concerns pole mounting of ODU, in 1+0 and 1+1 version, using following installation kits: - V32307 for ODU with frequency from 10 to 13 GHz - V32308 for ODU with frequency from 15 to 38 GHz - V32309 for ODU with frequency from 7 to 8 GHz Differences regard the dimensions and the presence of the centring ring (see Fig.81): - V32307 centring ring for antenna flange from 10 to 13 GHz - V32308 centring ring for antenna flange from 15 to 38 GHz - V32309 no centring ring (and relevant screws).

6.1.1INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions.

1+0 version

60 to 129 mm pole mounting kit: - centring ring and relevant screws - pole support system plus antenna (already assembled) and pole fixing brackets - 1+0 ODU support and relevant screws - ODU with Oring and devices for ground connection

1+1 version

60 to 129 mm pole mounting kit: - centring ring and relevant screws - pole support system plus antenna (already assembled) and pole fixing brackets - 1+0 ODU support - hybrid and relevant screws - polarization twist disk and relevant screws - 2 ODUs with Orings and devices for ground connection.

6.1.2REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.1 N.1 N.1 N.1 N.2 2.5 mm Allen wrench 3 mm Allen wrench 6 mm Allen wrench 13 mm spanner 17 mm spanner.

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step.

6.2INSTALLATION PROCEDURE
Installation procedure is listed below:

1+0 version
1 2 3 4 5 6 7

antenna polarization installation of the centring ring on the antenna installation of 1+0 ODU support installation onto the pole of the assembled structure installation of ODU antenna aiming ODU grounding

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 69 of 157 Rev./Ver.

02

1+1 version
1 2 3 4 5 6 7 8

antenna polarization installation of the centring ring on the antenna installation of 1+0 ODU support installation onto the pole of the assembled structure installation of hybrid installation of ODUs antenna aiming ODU grounding.

6.2.11+0 MOUNTING PROCEDURES 6.2.1.1Setting antenna polarization


Fig.81 Set the antenna in such a position to operate on its rear side. Locate the four M3 Allen screws around the antenna flange. Unscrew them (use 2.5 mm Allen wrench) and position the antenna flange according on: horizontal wave guide > vertical polarization, vertical wave guide > horizontal polarization. Screw again the four Allen screws (torque = 1 Nm).

6.2.1.2Installation of the centring ring on the antenna


Fig.81 Set the antenna in such a position to operate on its rear side. Locate the three holes around the antenna flange. Mount the centring ring onto antenna flange and tight it with the 3 Allen screws M4 (use 3mm Allen wrench, torque 2 = Nm).

6.2.1.3Installation of 1+0 ODU support


Fig.81 Mount the support onto assembled structure (pole support system plus antenna) using the four M8 Allen screws (use 6 mm Allen wrench, torque 18 = Nm). Two of the four screws, diagonally opposed, must be mounted with the two bushes around.

6.2.1.4Installation onto the pole of the assembled structure


Fig.81 Mount the assembled structure on the pole using the two pole fixing brackets and the four M10 screws (use 17 mm spanner, torque = 13 Nm); the heads of the screws are inserted on the antenna side, the four nuts and the springs between nut and brackets are inserted on bracket side.

6.2.1.5Installation of ODU (on 1+0 support)


Fig.82 Apply silicon grease (e.g. RHODOSIL PATE 4) on the Oring by protecting fingers with gloves. Fig.83 Bring the ODU with the two hands and position the ODU handle at the bottom side. The handle can assume the positions shown in the figure depending on the polarization. Position the ODU body near the support and align the wave guide of the ODU to the Wave guide of the antenna: respect to the position of wave guide alignment, turn the ODU body approx. 30 counterclockwise into the support and search for matching between reference tooth on the support (see Fig.84) and reference tooth on the ODU body. Fig.85 When alignment of the references teeth is achieved, turn the ODU body clockwise until rotation is stopped. In figure are shown ODU final position for both polarizations. Fig.84 When ODU positioning is over, secure ODU body on the support by tightening bolts (use 13mm spanner, torque = 6Nm).

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 70 of 157 Rev./Ver.

02

6.2.1.6Antenna aiming
Antenna aiming procedure for 1+0 version or 1+1 version is the same. Horizontal aiming: 5 operating on the 17 mm nut shown in Fig.86 with a 17 mm spanner, only after having loosen the two 17 mm nut on the pivot. Vertical aiming: 20 operating on the 13 mm nut shown in Fig.86 with a 13 mm spanner, only after having loosen the three 13 mm nut on the pole support. Once optimum position is obtained, tighten firmly all the nuts previously loosen. Tab.28 shows an example for 0.6m antenna and 75-114 mm pole with relevant screws and torque values.

6.2.1.7ODU grounding
ODU grounding is achieved with: M8 screw without washers M6 screw with washer as shown in Fig.87.

6.2.21+1 MOUNTING PROCEDURES


In further page are explained all the mounting step not already discussed in paragraph 16.5 1+0 MOUNTING PROCEDURES.

6.2.2.1Installation of Hybrid
Fig.88 The polarization disk must be always fixed on hybrid flange. Apply silicon grease (e.g. RHODOSIL PATE 4) on the Orings by protecting fingers with gloves. Bring the polarization twist disk with the position marker down. Insert the Oring into polarization twist disk. Vertical polarization: fix the twist disk on hybrid flange placing the marker of the disk towards V mark. Horizontal polarization: fix the twist disk on hybrid flange placing the marker of the disk towards H mark. In 13 GHz and 15 GHz ODUs the polarization disk is fixed to the hybrid flange by means of 3 screws as shown in Fig.89. Tighten progressively and alternatively the screws and the spring washer with following torque:

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 71 of 157 Rev./Ver.

02

Fig.90 Fix hybrid body to 1+0 support with four M8 bolts (use 13 mm spanner, torque = 18 Nm), tighten progressively and alternatively the bolts.

6.2.2.2Installation of ODUs (on hybrid for 1+1 version)


For both ODUs. Fig.82 Apply silicon grease e.g. RHODOSIL PATE 4 to the Oring by protecting fingers with gloves. Fig.83 Bring the ODU with the two hands and position the ODU handle at the bottom side. The handle can assume the positions shown in the figure depending on the polarization. Position the ODU body near the support and align the wave guide of the ODU to the wave guide of the hybrid: respect to the position of wave guide alignment, turn the ODU body approx. 30 counterclockwise and then insert the ODU body into the support. For 1+1 system the handle of the ODU is always positioned on the right. The polarization twist disk on the hybrid matches the antenna polarization. Fig.91 When alignment of the reference teeth is achieved, turn the ODU body clockwise until the rotation stops. In figure are shown ODUs final position. Fig.84 When ODU positioning is over, secure ODU body on the support by tightening bolts (use 17 mm spanner, torque = 6 Nm). WARNING: Internal codes (e.g. installation items, antennas, PCB) are here reported only as example. The Manufacturer reserves the right to change them without any previous advice.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 72 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 73 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 74 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 75 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 76 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 77 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 78 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 79 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 80 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 81 of 157 Rev./Ver.

02

7. INSTALLATION ONTO THE POLE OF THE ODUWITH RFS INTEGRATED ANTENNA

7.1FOREWORD
The installation onto the pole of the ODU with integrated antenna concerns both 1+0 and 1+1 version.

7.1.1INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions.

1+0 version

60 to 129 mm pole mounting kit: - centring ring and relevant screws - pole support system plus antenna (already assembled) and pole fixing brackets - 1+0 ODU support and relevant screws - ODU with Oring and devices for ground connection

1+1 version

60 to 129 mm pole mounting kit: - centring ring and relevant screws - pole support system plus antenna (already assembled) and pole fixing brackets - 1+0 ODU support - hybrid and relevant screws - polarization twist disk and relevant screws - 2 ODUs with Orings and devices for ground connection.

7.1.2REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)


N.1 N.1 N.1 N.1 N.2 2.5 mm Allen wrench 3 mm Allen wrench 6 mm Allen wrench 13 mm spanner 17 mm spanner.

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step.

7.2INSTALLATION PROCEDURE
Installation procedure is listed below:

1+0 version
1 2 3 4 5 6 7

antenna polarization installation of the centring ring on the antenna installation of 1+0 ODU support installation onto the pole of the assembled structure installation of ODU antenna aiming ODU grounding

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 82 of 157 Rev./Ver.

02

1+1 version
1 2 3 4 5 6 7 8 antenna polarization installation of the centring ring on the antenna installation of 1+0 ODU support installation onto the pole of the assembled structure installation of hybrid installation of ODUs antenna aiming ODU grounding.

7.2.11+0 MOUNTING PROCEDURES 7.2.1.1Setting antenna polarization


Fig.81 Set the antenna in such a position to operate on its rear side. Locate the four M3 Allen screws around the antenna flange. Unscrew them (use 2.5 mm Allen wrench) and position the antenna flange according on: horizontal wave guide > vertical polarization, vertical wave guide > horizontal polarization. Screw again the four Allen screws (torque = 1 Nm).

7.2.1.2Installation of the centring ring on the antenna


Fig.81 Set the antenna in such a position to operate on its rear side. Locate the three holes around the antenna flange. Mount the centring ring onto antenna flange and tight it with the 3 Allen screws M4 (use 3mm Allen wrench, torque 2 = Nm).

7.2.1.3Installation of 1+0 ODU support


Fig.81 Mount the support onto assembled structure (pole support system plus antenna) using the four M8 Allen screws (use 6 mm Allen wrench, torque 18 = Nm). Two of the four screws, diagonally opposed, must be mounted with the two bushes around.

7.2.1.4Installation onto the pole of the assembled structure


Fig.81 Mount the assembled structure on the pole using the two pole fixing brackets and the four M10 screws (use 17 mm spanner, torque = 13 Nm); the heads of the screws are inserted on the antenna side, the four nuts and the springs between nut and brackets are inserted on bracket side.

7.2.1.5Installation of ODU (on 1+0 support)


Fig.82 Apply silicon grease (e.g. RHODOSIL PATE 4) on the Oring by protecting fingers with gloves. Fig.83 Bring the ODU with the two hands and position the ODU handle at the bottom side. The handle can assume the positions shown in the figure depending on the polarization. Position the ODU body near the support and align the wave guide of the ODU to the Wave guide of the antenna: respect to the position of wave guide alignment, turn the ODU body approx. 30 counterclockwise into the support and search for matching between reference tooth on the support (see Fig.84) and reference tooth on the ODU body. Fig.85 When alignment of the references teeth is achieved, turn the ODU body clockwise until rotation is stopped. In figure are shown ODU final position for both polarizations. Fig.84 When ODU positioning is over, secure ODU body on the support by tightening bolts (use 13mm spanner, torque = 6Nm).

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 83 of 157 Rev./Ver.

02

7.2.1.6Antenna aiming
Antenna aiming procedure for 1+0 version or 1+1 version is the same. Horizontal aiming: 5 operating on the 17 mm nut shown in Fig.86 with a 17 mm spanner, only after having loosen the two 17 mm nut on the pivot. Vertical aiming: 20 operating on the 13 mm nut shown in Fig.86 with a 13 mm spanner, only after having loosen the three 13 mm nut on the pole support. Once optimum position is obtained, tighten firmly all the nuts previously loosen.

7.2.1.7ODU grounding
ODU grounding is achieved with: M8 screw without washers M6 screw with washer as shown in Fig.87.

7.2.21+1 MOUNTING PROCEDURES


In further page are explained all the mounting step not already discussed in paragraph 16.5 1+0 MOUNTING PROCEDURES.

7.2.2.1Installation of Hybrid
Fig.88 The polarization disk must be always fixed on hybrid flange. Apply silicon grease (e.g. RHODOSIL PATE 4) on the Orings by protecting fingers with gloves. Bring the polarization twist disk with the position marker down. Insert the Oring into polarization twist disk. Vertical polarization: fix the twist disk on hybrid flange placing the marker of the disk towards V mark. Horizontal polarization: fix the twist disk on hybrid flange placing the marker of the disk towards H mark. In 13 GHz and 15 GHz ODUs the polarization disk is fixed to the hybrid flange by means of 3 screws as shown in Fig.89. Tighten progressively and alternatively the screws and the spring washer with following torque:

Fig.90 Fix hybrid body to 1+0 support with four M8 bolts (use 13 mm spanner, torque = 18 Nm), tighten progressively and alternatively the bolts.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 84 of 157 Rev./Ver.

02

7.2.2.2Installation of ODUs (on hybrid for 1+1 version)


For both ODUs. Fig.82 Apply silicon grease e.g. RHODOSIL PATE 4 to the Oring by protecting fingers with gloves. Fig.83 Bring the ODU with the two hands and position the ODU handle at the bottom side. The handle can assume the positions shown in the figure depending on the polarization. Position the ODU body near the support and align the wave guide of the ODU to the wave guide of the hybrid: respect to the position of wave guide alignment, turn the ODU body approx. 30 counterclockwise and then insert the ODU body into the support. For 1+1 system the handle of the ODU is always positioned on the right. The polarization twist disk on the hybrid matches the antenna polarization. Fig.91 When alignment of the reference teeth is achieved, turn the ODU body clockwise until the rotation stops. In figure are shown ODUs final position. Fig.84 When ODU positioning is over, secure ODU body on the support by tightening bolts (use 17 mm spanner, torque = 6 Nm). WARNING: Internal codes (e.g. installation items, antennas, PCB) are here reported only as example. The Manufacturer reserves the right to change them without any previous advice.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 85 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 86 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 87 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 88 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 89 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 90 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 91 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 92 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 93 of 157 Rev./Ver.

02

8. INSTALLATION ONTO THE POLE OF ODU ASNWITH STANDARD LOCK


8.1 ODU COUPLING KIT
Two versions of ODU can be connected to ALplus2/ALCplus2 IDU: ODU AS and ODU ASN. Both versions need to be completed with a coupling kit to be connected to the mechanical structure for the installation.

8.1.1 ODU AS
ODU AS is factory assembled with a Fast Lock coupling kit (see Fig.103); for the installation it needs Oring and grounding bolt only.

8.1.2 ODU ASN


ODU ASN can mount two different coupling kits in order to obtain a Fast Lock ASN or a Standard ASN. After having mounted the proper coupling kit the ODU needs O-ring and grounding bolt.

8.1.2.1Fast lock coupling kit


The Fast Lock coupling kit is the same used in ODU AS and so after kit, O-ring and grounding bolt assembly, the ASN Fast Lock can be installed in the same way of ODU AS.

Coupling kit assembly procedure

See Fig.104 - Put the Fast Lock coupling kit on the ODU. Align the four holes of the coupling kit with the four nut screws on the ODU. Insert and tighten the four screws.

8.1.2.2Standard coupling kit


The standard coupling kit is mounted on ASN ODU by means of four screws.

Coupling kit assembly procedure

See Fig.105 - Put the standard coupling kit on the ODU. Align the four holes of the coupling kit with the four nut screws on the ODU. Insert and tighten the four screws.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 94 of 157 Rev./Ver.

02

8.2INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA


8.2.1ODU AS and ODU ASN (Fast Lock)
The installtion of ODUs with Fast Lock coupling kit is described in previous chapters.

8.2.2ODU ASN (Standard Lock)


Mounting kit 1+0 version
Centering ring and relevant screws M10 bolts ODU with O-ring and devices for ground connection

Mounting kit 1+1 version


Centering ring and relevant screws M10 bolts for hybrid and ODU mounting Hybrid mechanical body Polarization twist disk (see Fig.108) 2 ODUs with O-rings and devices for ground connection.

8.2.2.11+0 ODU
Install the antenna using the antenna installation guide (specific for each antenna) inside the antenna box provided by antenna producer. Keep attention to the polarization of the antenna feeder depending on requested polarization. After the antenna is installed onto the pole, the ODU must be installed, see Fig.106. Position the three holes circular flange (1) on the antenna flange and align the three holes on the circular flange with the three relevant holes on the antenna flange Insert and tighten the three 3mm M4 Allen screws (2) using a 3mm Allen wrench (torque = 2 Nm) Screw partially the four M10 bolts (3) on the antenna back plate: each bolt should be tightened to have the square head out of the hole of about 13-14mm (the thickness of hook (4), use 15mm spanner) Apply silicone grease (e.g. RHODOSIL PATE 4) to the O-ring, protecting fingers with gloves, and insert in the proper track on the ODU flange Position the ODU (5) vertically near the four bolts on the antenna flange and align the ODU to match the polarization of the antenna feeder: - vertical polarization: the handle (6) of the ODU is at the bottom left corner - horizontal polarization: the handle (6) of the ODU is at the bottom right corner After the right position has been found, rotate 30 counter clockwise the ODU and approach the ODU to the antenna flange in order to have the four slots of the Standard Lock cross between the four bolts Rotate 30 clockwise the ODU to hook each slots on the relevant bolt When each slot is firmly hooked on the relevant bolt, tighten each bolt (use 15mm spanner, torque=46mm) Optional: sun cover kit - Insert the sun cover and tie one of its bottom holes to the ODU handle by means of the black plastic strip included in the sun cover kit The ODU is ready to be connected to the IDU-ODU cable and to the grounding cable.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 95 of 157 Rev./Ver.

02

8.2.2.21+1 ODU
Install The antenna using the antenna installation guide (specific for each antenna) inside the antenna box by antenna prodicer. Keep attention to the polarization of the antenna feeder depending on requested polarization. After the antenna is installed onto the pole, follow the procedure below, see Fig.107. Mounting the hybrid (3) on the back of the antenna: Position the three holes circular flange (1) on the antenna flange and align the holes on the circular flange with the relevant holes on the antenna flange Insert and tighten the three 3mm M4 Allen screws (2) using a 3mm Allen wrench (torque = 2mm) Prepare the polarization disk (see Fig.108) with the twi O-rings: silicone grease e.g RHODOSIL PATE 4 must be applied to the O-ring, protecting fingers with gloves; each O-ring must be inserted in the proper track on each surface of the disk Mount always (with vertical and with horizontal polarization)the polarization disk on the hybrid flange (antenna side) as shown in Fig.108 and tighten the four screws (only three screws in 13 GHz and 15 GHz hybrid). The polarization disk must br oriented deprnding on requested polarization by antenna feeder (position V or H as shown in Fig.108. Torque values as in Tab.31.

8.3INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA


Diameter of the pole 60-114 mm

8.3.1ODU AS and ODU ASN (Fast Lock)


The installation of ODUs with Fast Lock coupling kit is described in previous chapters.

8.3.2ODU ASN (Standard Lock)


Mounting kit 1+0 version
Supporting plate, fixing bracket with M10 130mm bolts (with washer, spring and nut) 1 antenna side flange, variable as function of RF frequency, with relevant screws M10 25mm bolts for ODU mounting ODU with O-ring and devices for ground connection

Mounting kit 1+1 version


Supporting plate, fixing bracket with M10 130mm bolts (with washer, spring and nut) M10 25mm bolts for hybrid and ODUs mounting Hybrid mechanical body Polarization twist disk (see Fig.108) 2 ODUs with O-rings and devices for ground connection.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 96 of 157 Rev./Ver.

02

8.3.2.11 1+0 ODU


See Fig.109. Position the supporting plate (1) on the pole and fix the rear bracket (2) to it by means of the four 130 mm M10 bolt (3) with relevant washers, springs and nuts (use 15mm spanner, torque = 46Nm). Fix the antenna side flange (4) with the proper screws ( in Fig.109 the antenna flange is shown in two different positions depending on the polarization), the screw holes side is the side where the waveguide must be installed. On the supporting plate, on the opposite side respect to the antenna flange just mounted, insert in holes (5) on the supporting plate the four 25mm M10 bolts (3): screw them partially, each bolt should be tightened to have the square head out of the hole of about 13-14 mm (the thickness of hook (4), use 15mm spanner). Apply silicon grease (e.g. RHODOSIL PATE 4) to the O-ring, protecting fingers with gloves, and insert it in the proper track on the ODU flange. Position the ODU vertically near the four bolts on the supporting plate and align the ODU to match the polarization of the antenna flange: - vertical polarization: the handle of the ODU is at the bottom left corner - horizontal polarization: the handle of the ODU is at the bottom right corner After the right position has been found, rotate 30 counter clockwise the ODU and approach the ODU to the supporting plate in order to have the four slots of the Standard Lock cross between the four bolts Rotate 30 clockwise the ODU to hook each slots on the relevant bolt When each slot is firmly hooked on the relevant bolt, tighten each bolt (use 15 mm spanner, torque =46 Nm).

Mount the hybrid on the back of the antenna by means of four M10 bolts (4) (torque = 46 Nm) Mounting each ODU on the hybrid: Screw partially four M10 bolts (4) on the hybrid flange (ODU side): each bolt should be tightened to have the square head out of the hole of about 13-14 mm, use 15 mm spanner Apply silicon grease (e.g. RHODOSIL PATE 4) to the O-ring, protecting fingers with gloves, and insert in the proper track on the ODU flange Position the ODU (5) vertically near the four bolts on the antenna flange and align the ODU to match the polarization of the antenna feeder: horizontal polarization must be used, the handle (6) of the ODU is at the bottom right corner After the right position has been found, rotate 30 counter clockwise the ODU and approach the ODU to the antenna flange in order to have the four slots (7) of the Standard Lock cross between the four bolts on the hybrid Rotate 30 clockwise the ODU to hook each slots on the relevant bolt When each slot is firmly hooked on the relevant bolt, tighten each bolt (use 15 mm spanner, torque = 46Nm)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 97 of 157 Rev./Ver.

02

Optional: sun cover kit - Insert the sun cover and tie one of its bottom holes to the ODU handle by means of the black plastic strip included in the sun cover kit Now the ODU is ready to be connected to the IDU-ODU cable and to the grounding cable Repeat for the other ODU on the other side Optional: sun cover kit . Insert the sun cover and tie one of its bottom holes to the ODU handle by means of the blak plastic strip included in the sun cover kit Now the ODU is ready to be connected to the IDU-ODU cable and to the grounding cable.

8.3.2.21+1 ODU
See Fig.110. Position the supporting plate (1) on the pole and fix the rear bracket (2) to it by means of the four 130 mm M10 bolt (3) with relevant washers, springs and nuts (use 15 mm spanner, torque = 46 Nm) Mount the hybrid (4) on the back of the antenna by means of four 25 mm M10 bolts (5) (use 15 mm spanner with torque = 46 Nm) in the holes (6). Mounting each ODU on the hybrid: Screw partially four 25 mm M10 bolts positioning them in the holes (7) on the hybrid flange (ODU side): each bolt should be tightened to have the square head out of the hole of about 13-14 mm, use 15 mm spanner Apply silicon grease e.g. RHODOSIL PATE 4 to the O-ring, protecting fingers with gloves, and insert in the proper track on the ODU flange Position the ODU vertically near the four bolts on the antenna flange and align the ODU to match the polarization of the antenna feeder: horizontal polarization must be used, the handle of the ODU is at the botton right corner After the right position has been found, rotate 30 counter clockwise the ODU and approach it to the antenna flange in order to have the four slots of the Standard Lock cross between the four bolts on the hybrid Rotate 30 clockwise the ODU to hook each slots on the relevant bolt When each slot is firmly hooked on the relevant bolt, tighten each bolt (use 15 mm spanner, torque = 46 Nm) Optional: sun cover kit - insert the sun cover and tie one of its bottom holes to the ODU handle by means of the black plastic strip included in the sun cover kit Now the ODU is ready to be connected to the IDU-ODU cable and to the grounding cable Repeat for the other ODU on the other side

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 98 of 157 Rev./Ver.

02

8.3.2.3 Waveguide towards the antenna


After having installed the ODU in 1+0 configuration or in 1+1 configuration, the waveguide towards the antenna must be installed. 1+0: the waveguide must be fixed to the antenna flange on the supporting plate of the ODU. In case of flexible waveguides, an excessive folding can damage the waveguide, see Tab.32 for details. 1+1: the waveguide must be fixed to the hybrid. In case of flexible waveguides, an excessive folding can damage the waveguide, see Tab.32 for details.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 99 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 100 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 101 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 102 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 103 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 104 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 105 of 157 Rev./Ver.

02

9.

GENERAL INSTALLATION

9.1RG8 Cable Runway

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 106 of 157 Rev./Ver.

02

9.2 Outdoor Grounding

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 107 of 157 Rev./Ver.

02

9.3Indoor Installation
The number of E1 cable will be install based on the existing E1 installed. Scenario 1 2 3 Existing E1 1E1 4E1 5E1 8E1 9E1- 16E1 Number of E1 to be install 8 E1 16 E1 24 E1

Note : Any additional subject on Digi request

Scenario 1:

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 108 of 157 Rev./Ver.

02

Scenario 2:

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 109 of 157 Rev./Ver.

02

Scenario 3:

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 110 of 157 Rev./Ver.

02

Grounding tapping sample for indoor site-structure monople Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 111 of 157 Rev./Ver.

02

Grounding tapping sample for indoor site-structure tower Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 112 of 157 Rev./Ver.

02

Grounding tapping sample for indoor site-structure boom Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 113 of 157 Rev./Ver.

02

9.4Outdoor Installation

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 114 of 157 Rev./Ver.

02

Grounding tapping sample for outdoor site-structure monople Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 115 of 157 Rev./Ver.

02

Grounding tapping sample for outdoor site-structure tower Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 116 of 157 Rev./Ver.

02

Grounding tapping sample for outdoor site-structure boom Remark: Only 2 point for grounding tapping needed according to this project. For additional point will add as per client requirment. Details as per below tabble, Grounding Point Point 1 Point 2 TappingLocation Nearest grounding bar to the radio/antenna Before the entries cabin/outdoor cabinet

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 117 of 157 Rev./Ver.

02

10.

LABELING

10.1Labeling Tools
-BROTHERS, CASIO ( KL-60 EZ)-Label Printer (Battery Operated)
-Cartridge size: 9mm height for all indoor labeling and the length is dependant on the length of the message. -Background Colour is Yellow -T cable tie.

-Alphabet Template = 40mm antenna labeling.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 118 of 157 Rev./Ver.

02

10.2Indoor Labeling.
10.2.1 IDU Labeling.
1st Sticker: First Row (Link ID refer SSR) Second Row (Link Name)

2nd Sticker: Third Row (Equipment Configurations) Fourth Row (Receive & Transmit Details) Size: 2x2

3rd Sticker: fifth Row (Agent IP Address)

Example: 1st Sticker

LINK ID : 193 TESCO EXTRA OUTDOOR(xxxxx) TO WORLD WIDE(xxxxx)


2nd Sticker

ALC+2/4FE32E1(18G-P)/2,2/7V RSL:xxx Tx POWER:xxx Tx:7442MHZ Rx:7596MHZ

3rd Sticker

AGENT IP ADDRESS: XXX.XXX.XXX.XXX

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 119 of 157 Rev./Ver.

02

PATCH PANEL/ DDF RACK LABELING

TESCO XXXXX, 32E1

10.2.2Equipment Rack Labeling.


First Row( Rack No.) Size : 3x1 Example :

RACK 3

10.2.3 DC Breaker Labeling at Rectifier.


First Row ( POWER RACK No.) Size : 2x1

Example :

POWER A RACK3

10.2.4 DC Breaker Labeling at Equipment Rack DC PDB for Main Power.


First Row ( POWER RACK No.) Size : 2x1

Example :

POWER A RACK3

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 120 of 157 Rev./Ver.

02

10.2.5DC Breaker Labeling at Rack DC PDB for ALCplus2 Power Supply


Main Power Supply. First Row (MAIN), site LRD, far end site id Second Row( Direction of the Link) Size : 2x2

Example :

MAIN SHT XXXXX

Standby Power Supply. First Row (PWR STBY) Second Row( Direction of the Link) Size : 2x2

Example :

STBY SHT XXXX

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 121 of 157 Rev./Ver.

02

10.2.6Power Cabel labeling at ALCplus2 IDU.


Main Power Supply. First Row (POWER) Second Row(MAIN/STANDBY) Size : 2x1

Example :

POWER MAIN

POWER STANDBY

10.2.7IF Cabel labeling at ALCplus2 IDU.


First Row (IF MAIN/STANDBY) Second Row ( Direction of the link) Size : Auto

Example :

IF MAIN WORLD WIDE XXXXX

IF STANDBY WORLD WIDE XXXXX

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 122 of 157 Rev./Ver.

02

10.2.8IF Cabel labeling before and after Surge Aresstor.


First Row (IF MAIN/STANDBY) Second Row ( Direction of the link) Size : Auto

Example :

IF MAIN WORLD WIDE xxxxx

IF STANDBY WORLD WIDE XXXXX

10.2.9SCSI Cabel Labeling at Both ends.


First Row (site ID ,E1 follow by port no) Size : 2x1

Example :

XXXXX E1 17 - 32

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 123 of 157 Rev./Ver.

02

10.2.10Baseband cable Labeling at Patch Panel.


Label at e1 port 1, 8, 9,16,17,24,25 and 32 TX and RX side. Size : 2x1

Example :

XXXXX E1 1 IN

XXXXX E1 1 OUT

10.2.11DDF Rack Labeling

Format DDF Rack No. Size : 2x1

Example :

DDF 3

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 124 of 157 Rev./Ver.

02

10.2.12 DDF Frame Labeling


Format : (FULL NAME FAR END OF SITE,SITE ID, NO. OF E1,PRINT VERTICAL) Size : 2x1

Example :

TESCO XXXXX, 32E1

10.2.13Baseband Cable Labeling at DDF

Label at e1 port 1, 8, 9,16,17,24,25 and 32 TX and RX side. Format : (SITE ID, SHORT NAME, 1 IN OR 1 OUT) Size : 2x1

Example :

XXXXX SHT 1 IN

XXXXX SHT 1 OUT

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 125 of 157 Rev./Ver.

02

10.3Outdoor Labeling

10.3.1Antenna Labeling.
Antenna should be label as TO follow by direction of the link. Format : (DG Dataran Sunway)

Labeling need to be water proof (Clear spray need to be sprayed)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 126 of 157 Rev./Ver.

02

10.3.2IF Cabel labeling at ODU.


First Row (FAR END ID, SHORT NAME, AND MAIN/STANDBY)

Example : (1367A WORLD WIDE MAIN) OR (1367A WORLD WIDE STANDBY)

1367A WORLD WIDE MAIN 1367A WORLD WIDE STANDBY

METAL CABLE TIE

Labeling Abbreviations

*KG as Kampung *BDR as Bandar *PLU as Pulau *LRG as Lorong *LDG as Ladang

*Masjid as Masjid *SG as Sungai *BKT as Bukit *BT as Batu *GNG as Gunung

*PMTG as Permatang *JLN as Jalan *PT as Parit *Taman as Taman

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 127 of 157 Rev./Ver.

02

11.

INSTALLATION PICTURE

11.1INSTALLATION SCENARIO
11.1.1Billboard (Indoor Equiment)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 128 of 157 Rev./Ver.

02

11.1.2Monopole (Outdoor Equipment)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 129 of 157 Rev./Ver.

02

12.0 SITE WORKS


12.1 Antenna structure supports

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 130 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 131 of 157 Rev./Ver.

02

6m dia

6 meter 76mm-diameter

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 132 of 157 Rev./Ver.

02

6m diameter 114mm
REF :MN.00024.E 004
Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 133 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 134 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 135 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 136 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 137 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 138 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 139 of 157 Rev./Ver.

02

12.2 Scopes and requirements


Antenna mount structure provisioning is limited to tripod floor mount,all appropriate brackets,fasteners,booms and etc. Scope does not include the provisioning of tower or mast.

12.3 Cable management and cable entries

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 140 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 141 of 157 Rev./Ver.

02

Roxtec photo for cable entries

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 142 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 143 of 157 Rev./Ver.

02

13.0 Standard Procedure Installation 13.1 Checking material on site


Unpacking the Equipment
After the project begins, the project supervisor should unpack and inspect the equipment togetherwith the customer.For a non-turnkey project, when unpacking, both the customer and the project supervisor shouldbe present. If one party unpacks the equipment when the other party is not present, the unpacking party shall take responsibilities for any possible error.For a turnkey project, the project supervisor and the order management engineer shall unpack, inspect and hand over the equipment together, and sign for the confirmation. The procedures for unpacking and inspecting the equipment and reporting equipment problems are the same as those for a non-turnkey project, except that the customer does not need to sign on relevant documents.After qualified initial acceptance, the equipment shall be handed over to the customer.The following describes how to unpack, inspect and hand over the equipment for a non-turnkeyproject.

Checking the Equipment

For each site, there is a packing list for delivered equipment. Before unpacking, the project supervisor should check the cargoes according to the packing list together with the customer. Prerequisite The equipment must be delivered to the site. Both the project supervisor and the customer must be present. Procedure Step 1 Print the packing list according to the electronic ship order. Step 2 According to the packing list, check the number of the packing boxes and the deliverydestination. Step 3 Check the outer package. If any of the following cases is identified, stop unpacking immediately. The outer package is severely damaged. There is water leakage on the outside packaging box. There is rust or water on the equipment. Find the damage causes and report the situation to the local representative office.

13.2 Assemble Pole (Refer 5.2.1)

13.3 Assemble Antenna


REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) N.1 N.1 N.1 N.1 N.2 2.5 mm Allen wrench 3 mm Allen wrench 6 mm Allen wrench 13 mm spanner 17 mm spanner.

Warning: if screwing operation concerns more than one screw or bolt, tighten subsequently everyone and its opposite, step by step. MOUNTING PROCEDURES Setting antenna polarization (Refer 11.1.2.1) Installation of the centring ring on the antenna(Refer 11.1.2.2) Installation of 1+0 ODU support(Refer 11.1.2.3) Installation onto the pole of the assembled structure(Refer 11.1.2.4)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 144 of 157 Rev./Ver.

02

13.4 Preparation Work


Preparing Documents and Tools To guarantee a smooth installation of the equipment, prepare relevant documents and tools. Documents Required documents include two categories, engineering design documents and installation guide documents.

AA certificate and LB need to be laminated and keep it at sites.


Tools Required tools include common tools, special tools and instruments. Checking Installation Conditions Before starting the installation, check the installation conditions on the site and make a record.If the installation conditions do not meet the requirements, make changes accordingly. Checking the Installation Conditions of the IDU Items that need to be checked include the construction, location, temperature, humidity, dustproof measures, fire-proof measures, and antistatic measures. Checking the Installation Conditions of the ODU Items that need to be checked include the tower and the mast. Checking the Lightning-Proof and Grounding System Items that need to be checked include the indoor and outdoor grounding systems. Checking the Power System Items that need to be checked include the AC power system and the DC power system. Checking Auxiliary Devices and Cables Items that need to be checked include the Digital Distribution Frame (DDF), the Optical Distribution Frame (ODF), outdoor cables and trunk cables.

13.5 Installation of ODU


Installation of ODU (on 1+0 support)(Refer 11.1.2.1) Antenna aiming(Refer 11.1.2.2) ODU grounding(Refer 11.1.2.3) 1+1 MOUNTING PROCEDURES(Refer 11.1.3) Installation of Hybrid(Refer 11.1.3.1)

Connect back the BNC port after installation complete

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 145 of 157 Rev./Ver.

02

13.6 Fixing IF Connector for IF cable


Manually fasten the type-N connector or use a torque wrench with a force moment of 1.7 Nm, to avoid damaging the type-N connector.When routing or bending the IF cable, do not use the type-N connector of the IF cable or the IF port of the ODU as the stress point or pivot point, to avoid damaging the type-N connector or IF port. Procedure Step 1 Depending on the distance between the IDU and the ODU, cut off a length of IF cable with a slack of 3 m to 5 m. Step 2 Make a connector for the end that is connected to the ODU. Take protective measures for the connector to avoid damage to the connectors during hoisting and routing of the IF cables. Step 3 Affix temporary labels to both ends of the IF cable. Step 4 Leave enough slack of the IF cable for routing and binding it along the mast, wiring ladder and wiring frame. Step 5 Connect the type-N connector of the IF cable to the surge end of the lightning arrester, and tighten the connector.Manually fasten the type-N connector or use a torque wrench with a force moment of 1.7 Nm,to avoid damaging the type-N connector. Step 6 Waterproof the connection between the ODU and the IF cable. Step 7 Make a connector for the end that is connected to the IF jumper.

13.7 Lift and installation pole


Mount pole supporting system with relevant pole fixing brackets following antenna aiming direction as indicated by arrow. Antislide strip should result at the centre of supporting plate. Supporting system should lean against antislide clamp with the tooth as in Fig.66. Position the antenna in such a way that bolt in position A or D of Fig.63 cross through hole E of Fig.67. Secure the support system to the pole by means of the pole fixing brackets and relevant fixing bolts.(Refer 5.2.1)

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 146 of 157 Rev./Ver.

02

13.8 Installation of 19 rack and DDF rack


Securing to floor 1. Place the rack upright, without the adjustable feet, and position it according to a layout plan. 2. Put marks through the holes, remove the rack and drill holes in the floor. 3. Put expansion plugs in the holes and hammer gently into place. 4. Mount the adjustable feet (nominal height 28 mm) and place the rack into position. 5. Insert the screws and washers and align the rack to correct vertical position by adjusting the feet. Then tighten the screws. 6. All the new rack must be grounded.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 147 of 157 Rev./Ver.

02

13.9 Installation of microwave antenna


Set the antenna in such a position as to be able to operate on its rear side. Locate the five threaded holes around antenna flange. Mount centring ring onto antenna flange and tight it with 3 calibrated bolts. Caution: centring ring should be mounted so that the screws do not stick out. Define if the antenna will be mounted with vertical or horizontal polarization. Check that free drain holes stay at bottom side. Mount bolt type M10x30, in position A leaving it loose of 2 cm approx. With horizontal polarization mount bolt type M10x30 in position D, leaving it loose of 2 cm approx. Mount antislide strip onto the pole. Place blocks as in Fig.64 following antenna aiming direction. Tighten the strip with screwdriver. Rotate the antenna body until the remainder three antenna holes coincide with the three support holes. Secure the antenna to the support by thightening the relevant passing through bolts.

14.0 Installation of DCPDB


DCPDB comming together with new 19 rack and already installed on it.

14.1 Installation of IDU (Refer 1.3) 14.2 Water proofing & IF cable route
The protection grounding cable of the ODU must be installed.Before the IF cable enters the IDU room, make waterproof curves with the IF cable.First bind the IF cable to avoid its type-N connector being pulled. Under the ODU, make waterproof curves with the IF cable.To ground the IF cable, first determine the grounding point depending on the installation mode and the length of the IF cable, and then ground the cable by using the grounding Kit. Minimum the slack in IF cable at Antenna during the installation.

14.3 Installation of E1 cable


Cable type -Cable 8CX 75 OHM ST213/2 CT1320 -Cable 16CX 75 OHM ST218/2 CT1320 Connector type -Connector BNC Male COAX STR.ST212 -Connector CX 1,6/5,6 Female x ST212 -Connector CX 1,6/5,6 male x ST212

E1 cable will run away from patch panel to DDF via existing/new cable ladder

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 148 of 157 Rev./Ver.

02

14.4 IF cable routing


One end of the IF cable is connected to the ODU, while the other end is connected to the IF jumper from the IDU.

14.5 Labeling (refer 10.0) -size 9mm

14.6 Installation of power cable


The DC power cable should be routed from the DC distribution cabinet or the DC distribution box. The cable diameter should meet the design requirement.

14.7 Site cleaning All debris creating,packages shall be removed immediately after installation complete. Equipment room shall be left clean as before commencement of installation. 14.8 Power on

By powering on the equipment, you can check if the hardware system of the equipment and the power system are normal.The hardware installation must be complete, and it should pass the installation check.The input power must be available. When the test value of the voltage is not within the range, first clear the fault of the powerequipment. The abnormal voltage can cause damage to the equipment, even personal injury.

14.9 Final checking

After the installation, check out the results. For any unqualified items, correct them as soon as possible.Check out the installation of the IDU chassis, IDU cables, IDU cabinet, power cables, and grounding cables of the cabinet.Check out the installation of the ODU, ODU cables, antenna, and hybrid coupler. If the ODU is separately mounted to the antenna, check the installation of the separate mount parts.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 149 of 157 Rev./Ver.

02

15.0 RG cable characteristic

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 150 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 151 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 152 of 157 Rev./Ver.

02

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 153 of 157 Rev./Ver.

02

16.0 Design loading and standards Tripods, T-brackets, boom, SEL-bracket, cable-ladder and roxtec made reference in this document comforms andin compliant to Digi version 4 specification. 17.0 Boom/bracket details and standards (refer 12.0-pre endorse by DG)
-New boom design for tower (refer to 12.0) -New poles design for rooftop(refer to 12.0) -Wind brace Already intergrated with antenna

18.0 fabrication Rack


Racks are fabricated in accordance to Digi Specification 42U , 19inch open rack. Fabricated and supplied by DiGi panel supplier

Standard requirement/design requirement -Concrete plinth

For the antenna mounting structure please refer to 12.0 For equipment not in SIAE scope

-Special bracket
n/a

-Labelling size (refer 10.0)


Use 9mm catridge

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 154 of 157 Rev./Ver.

02

19.0 IF panel plate Option 1 (vertical). Will install when there are space at existing 19 rack.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 155 of 157 Rev./Ver.

02

Option 2 (horizontal) Will install when there are no space at existing 19 rack.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 156 of 157 Rev./Ver.

02

20.0 Impedance at cell

21.0 Surge arrestor

SM radios are EN 301 489 compliant. As such Surge arrestors are not recommended. Please find appended EN 301 489 recommendations.

REF :MN.00024.E 004


Siae Microelettronica All rights reserved

INSTALLATION GUIDELINES ALCPLUS2

Issued by

Approved by LUCARELLI MOHD RIZAL LEMAN ALFREDO

Date 04/14/11

Page 157 of 157 Rev./Ver.

02

Vous aimerez peut-être aussi