Vous êtes sur la page 1sur 1

Written dimensions on these drawings shall have precedence over scaled dimensions.

Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other

PLUMBING KEY NOTES AND SCHEDULE GENERAL PLUMBING NOTES

1. ALL WORK IS ASSOCIATED WITH NEW CONSTRUCTION. VERIFY EXACT


P1: FOR CONTINUATION SEE CIVIL / SITE PLAN. PIPE SIZE IS NOTED. LOCATIONS OF ALL EQUIPMENT TO BE PLUMBED PRIOR TO THE
COMMENCEMENT OF WORK. REFER TO ARCH. PLANS FOR LOCATIONS OF ALL
P2: NEW GATE VALVE IN BROOKS BOX LABELED 'WATER'. SAID EQUIPMENT. ALL FIXTURES, PIPING, ACCESSORIES, COMPONENTS, ETC.
SHALL BE NEW.
P3: CAP PIPING IN WALL FOR FUTURE USE WITH FUTURE TREATMENT TABLE
SINK. 2. COMPLETE AND WORKING PLUMBING SYSTEMS SHALL BE IN ACCORDANCE
property rights in these documents. These documents are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are they to be assigned to a third party without first obtaining the written permission and written consent of OB+Architecture Inc. In the event of unauthorized use of these documents by a third party, the third party shall hold OB+Architecture Inc. harmless and agrees to remunerate OB+Architecture Inc.

WITH 2004 FLORIDA BUILDING/PLUMBING CODE AND LOCAL AUTHORITY HAVING


P4: PROVIDE AND INSTALL NEW STOP AND TUBE FOR WATER CONNECTION AT JURISDICTION (AHJ).
REFRIGERATOR. 3/8" CW.
3. PRESSURE AND HYDROSTATICALLY TEST THE PIPING, AS APPLICABLE, TO
P5: PROVIDE AND INSTALL NEW STOP AND TUBE FOR WATER CONNECTION AT INSURE THE ABSENCE OF LEAKS IN ACCORDANCE WITH THE 2004 FLORIDA 2"
COFFEE AUTO FILL. 3/8" CW. BUILDING/PLUMBING CODE. DISINFECT ALL DOMESTIC WATER PIPING IN
ACCORDANCE WITH THE 2004 FLORIDA BUILDING/PLUMBING CODE. SUPPORT
P6: WHERE AIR ADMITTANCE VALVES (AAV) ARE NOT EXPOSED AND ALL PIPING IN ACCORDANCE WITH THE 2004 FLORIDA BUILDING/PLUMBING
ACCESSIBLE WITHIN THE ROOM THEY SHALL BE INSTALLED CONCEALED IN CODE.
1 THE WALL CAVITY BELOW THE CEILING, IN ACCORDANCE WITH THE
MANUFACTURER'S INSTALLATION REQS. AND VENTILATED AND ACCESSIBLE 4. ALL NEW WASTE DRAIN AND VENT PIPING SHALL BE PVC DWV. TRENCHES
2"
THROUGH A WALL GRILLE. PLUMBING CONTRACTOR SHALL FURNISH AND SHALL BE BACKFILLED AND COMPACTED. NEW CW AND HW PIPING SHALL BE 2"
INSTALL AN OFF WHITE 6" X 6" ALUMINUM LOUVERED FACE WALL GRILLE
EQUAL TO TITUS 350FL WITH 35 DEGREE BLADES FOR VISION
S-40 CPVC WITH SOLVENT WELDED FITTINGS. WRAP NEW HOT WATER PIPING
WITH 1" R-4 PER INCH (PER THE 2004 FLORIDA MODEL ENERGY CODE)
4"
OBSTRUCTION. CELLULAR RUBBER INSULATION EQUAL TO ARMSTRONG ARMAFLEX. NOTE:
BRANCH PIPING LESS THAN 12' MAY BE INSULATED WITH 1/2" INSULATION PER
L-1: WHITE COUNTERTOP 19" VITREOUS CHINA LAVATORY. AMERICAN SAME CODE. CONTRACTOR MAY SUBSTITUTE FIBERGLASS INSULATION WITH
STANDARD 0491.019 OR EQUAL. PROVIDE AMERICAN STANDARD 2385.404 SAME INSTALLED R VALUE.
CP SINGLE LEV. FAUCET, GRID DRAIN, P TRAP, AND STOPS. 0.5" CW. 0.5"
HW. 1.5" TRAP. 5. SECURE ALL REQUIRED PERMITS AND PAY ALL ASSOCIATED FEES.

L-2: WHITE HANDICAPPED ACCESSIBLE WALL HUNG VITREOUS CHINA 6. BUILDING IS PROTECTED WITH AN APPROVED BACKFLOW PREVENTER AS
LAVATORY. AMERICAN STANDARD 0355.012 OR EQUAL. PROVIDE AMERICAN TUB-1
STANDARD 2385.404 CP SINGLE LEV. FAUCET, OFFSET GRID DRAIN, P TRAP,
SPECIFIED BY THE CIVIL ENGINEER.
4" FD-1 3" FD-1 issued: ADVANCE REVIEW 21 JULY 2008

ADA TRAP WRAP WHITE INSULATION KIT, AND STOPS. 0.5" CW. 0.5" HW. 1.5" 7. PROVIDE WATER HAMMER ARRESTORS IN ACCORDANCE WITH THE 2004
revised:
TRAP. FLORIDA BUILDING/PLUMBING CODE AND THE PDI.
1 17 OCT 2008
BLDG DEPT COMMENTS
WC-1: WHITE FLOOR MOUNTED ELONGATED TANK TYPE WATER CLOSET. 8. TRENCHES AND ASSOCIATED SCOPE OF WORK IN KENNEL AREA ILLUSTRATED
AMERICAN STANDARD CADET OR EQUAL. (1.6 GALLONS PER FLUSH). ON ARCHITECTURAL PLANS. COORDINATE WITH ALL TRADES.
PROVIDE STOP. PROVIDE WHITE OPEN FRONT SEAT EQUAL TO OLSONITE P3
10CC. 0.5" CW. INTEGRAL TRAP.

WC-2: HANDICAPPED ACCESSIBLE WHITE FLOOR MOUNTED ELONGATED TANK


TYPE WATER CLOSET. AMERICAN STANDARD CADET RIGHT HEIGHT OR
EQUAL. (1.6 GALLONS PER FLUSH). PROVIDE STOP. PROVIDE WHITE OPEN
FRONT SEAT EQUAL TO OLSONITE 10CC. 0.5" CW. INTEGRAL TRAP.

HD-1: 2" HUB DRAIN WITH 2" TRAP AND 2" X 3" HUB. PRIME WITH TRAP PRIMER OFF
WATER HEATER PER WH DETAIL.
R1 RISER #1: WASTE & VENT
SCALE: NOT TO SCALE
EWC-1: WALL MOUNTED BI-LEVEL ADA ELECTRIC WATER COOLER. 8 GALLONS AT 50
F. 4.8 AMPS AT 120 VAC. ELKAY EZSTL8C OR EQUAL. PROVIDE P TRAP AND CENTRAL
FLORIDA
STOP. 0.5" CW. 1.5" TRAP.

3" FD-1: 3" OUTLET FLOOR DRAIN WITH 5" DIA. STRAINER, TRAP PRIMER
CONNECTION, AND CAST IRON BODY. ZURN Z415PNL OR EQUAL. 3" TRAP.

4" FD-1: 4" OUTLET FLOOR DRAIN WITH 5" DIA. STRAINER, TRAP PRIMER
CONNECTION, AND CAST IRON BODY. ZURN Z415PNL OR EQUAL. 4" TRAP.

MS-1: THERMOPLASTIC 24" X 24" X 10" HIGH MOP SINK EQUAL TO FIAT MSB2424.
PROVIDE WITH SPEAKMAN SC-5811-RCP SERVICE FAUCET AND WALL

FCO:
BRACE, AND VACUUM BREAKER. 0.5" CW. 0.5" HW. 3" TRAP.

FLOOR CLEANOUT EQUAL TO ZURN Z14004"NL. PROVIDE BRASS TOP.


ANIMAL
HB-1: HOSE BIBB WITH VACUUM BREAKER. WOODFORD MODEL 24P OR EQUAL.
0.5" CW.
HOSPITAL
EWH-1: 50 GALLON ELECTRIC WATER HEATER WITH INTEGRAL HEAT TRAPS. 208 address: 1201 ALAFAYA TRAIL
VAC, SINGLE PHASE, 9 KW. RUUD PE-50 OR EQUAL. PROVIDE MIN. 6" HIGH
CAST IRON STAND, APPROVED PAN, T/P RELIEF VALVE, THERMAL OVIEDO, FLORIDA
EXPANSION VALVE, THERMOMETER, AND TANK DRAIN VALVE. 0.75" CW. 0.75"
HW. 32765

SH-1: COMPLETE NON ADA PREFAB THERMOPLASTIC SHOWER WITH RECEPTOR,


FLOOR DRAIN, ANTI SCALD VALVE, SLIDING ROD, HAND HELD HOSE WITH project
VACUUM BREAKER, ETC. LASCO, SPEAKMAN, OR EQUAL. 3' X 6'. 0.5" CW. 0.5"
number: 2007-12
HW. 2" TRAP.

LT-1: LAUNDRY TUB OF MOLDED POLYMER CONSTRUCTION ON ENAMELED STEEL


LEGS EQUAL TO FIAT FL-1 WITH DECK FAUCET EQUAL TO FIAT A-1. 20
for such use in an amount equal to the original fee for the original documents, plus legal fees, court costs, collection fees and other costs.

GALLONS. 23" X 20" AND TOP AT 33.5". 0.5" CW 0.5" HW. 1.5" SAN. PROVIDE
STOPS AND DOME STRAINER.
P3
MECHANICAL ENGINEER
TT-1: TREATMENT TABLE SPECIFIED BY OTHERS WITH INTEGRAL SST SINK, HOSE,
AND FAUCET . 0.5" CW 0.5" HW. 1.5" SAN. PROVIDE STOPS.
A. PETER TANKEL, P.E.
702 DENTON ROAD
TUB-1: TUB FOR BATHING ANIMALS WITH ENTRY RAMP SPECIFIED BY OTHERS WITH WINTER PARK, FL 32792
INTEGRAL FAUCET AND HOSE. 0.5" CW 0.5" HW. 2" SAN. PROVIDE STOPS. PE 41231

WMB-1: WASHING MACHINE BOX. WALL MOUNTED WITH INTEGRAL STOPS, HOSE, P
TRAP, ETC. GUY GREY, OATEY, OR EQUAL. 0.5" CW 0.5" HW. 1.5" SAN

S-1: SINGLE COMPARTMENT COUNTERTOP STAINLESS STEEL SINK EQUAL TO title:


DAYTON 1719-3. PROVIDE T AND S BRASS OR EQUAL CHROME FAUCET WITH
SWIVEL GOOSENECK SPOUT, WRIST BLADES, P TRAP, AND ANGLE STOPS.
0.5" CW. 0.5" HW. 1.5" TRAP.
PLUMBING RISER
DIAGRAMS
S-2: TWO COMPARTMENT COUNTERTOP STAINLESS STEEL SINK EQUAL TO
DAYTON 3322-4. PROVIDE T AND S BRASS OR EQUAL CHROME FAUCET WITH drawn:
SWIVEL GOOSENECK SPOUT, WRIST BLADES, P TRAP, AND ANGLE STOPS.
JLP
PROVIDE WITH HOSE. 0.5" CW. 0.5" HW. 1.5" TRAP. reviewed:
OB / RG
S-3: TWO COMPARTMENT COUNTERTOP STAINLESS STEEL SINK EQUAL TO date:
DAYTON 3322-4. PROVIDE T AND S BRASS OR EQUAL CHROME SINGLE 21 JULY 2008
LEVER FAUCET, BASKET STRAINERS, P TRAP, AND ANGLE STOPS. PROVIDE
WITH HOSE. 0.5" CW. 0.5" HW. 1.5" TRAP. PROVIDE WITH GARBAGE DISPOSAL ELECTRIC HOT WATER DETAIL R2 RISER #2: DOMESTIC WATER lman:
PS-P3.1
EQUAL TO BADGER V. SCALE: NOT TO SCALE SCALE: NOT TO SCALE sheet setup:
MOJA-PLUMBING
DW-1: DISHWASHER SPECIFICATIONS BY OTHERS. CONTRACTOR INSTALLED. sheet
number:
PROVIDE STOP, HW SUPPLY AND DRAIN HOSE. 0.5" HW.

P3.1