Académique Documents
Professionnel Documents
Culture Documents
Contractor shall verify and be responsible for all dimensions and conditions on the job. OB+Architecture Inc. must be notified immediately in writing of any variation from the dimensions and conditions shown on these drawings. Field verify all conditions prior to laying out or fabricating associated work. Bring to the architect's attention any deviation from designed conditions and field conditions prior to ordering
materials and installing work, and cooperate with architect to modify such conditions at no additional cost to the owner, architect or architect's consultants. Shop details must be submitted to the architect's office and reviewed by the architect prior to ordering materials, fabrication and delivery to the job site, unless otherwise provided for under the specific contractual agreement between the architect and client. OB+Architecture Inc. expressly reserves its common law copyright and other
L-2: WHITE HANDICAPPED ACCESSIBLE WALL HUNG VITREOUS CHINA 6. BUILDING IS PROTECTED WITH AN APPROVED BACKFLOW PREVENTER AS
LAVATORY. AMERICAN STANDARD 0355.012 OR EQUAL. PROVIDE AMERICAN TUB-1
STANDARD 2385.404 CP SINGLE LEV. FAUCET, OFFSET GRID DRAIN, P TRAP,
SPECIFIED BY THE CIVIL ENGINEER.
4" FD-1 3" FD-1 issued: ADVANCE REVIEW 21 JULY 2008
ADA TRAP WRAP WHITE INSULATION KIT, AND STOPS. 0.5" CW. 0.5" HW. 1.5" 7. PROVIDE WATER HAMMER ARRESTORS IN ACCORDANCE WITH THE 2004
revised:
TRAP. FLORIDA BUILDING/PLUMBING CODE AND THE PDI.
1 17 OCT 2008
BLDG DEPT COMMENTS
WC-1: WHITE FLOOR MOUNTED ELONGATED TANK TYPE WATER CLOSET. 8. TRENCHES AND ASSOCIATED SCOPE OF WORK IN KENNEL AREA ILLUSTRATED
AMERICAN STANDARD CADET OR EQUAL. (1.6 GALLONS PER FLUSH). ON ARCHITECTURAL PLANS. COORDINATE WITH ALL TRADES.
PROVIDE STOP. PROVIDE WHITE OPEN FRONT SEAT EQUAL TO OLSONITE P3
10CC. 0.5" CW. INTEGRAL TRAP.
HD-1: 2" HUB DRAIN WITH 2" TRAP AND 2" X 3" HUB. PRIME WITH TRAP PRIMER OFF
WATER HEATER PER WH DETAIL.
R1 RISER #1: WASTE & VENT
SCALE: NOT TO SCALE
EWC-1: WALL MOUNTED BI-LEVEL ADA ELECTRIC WATER COOLER. 8 GALLONS AT 50
F. 4.8 AMPS AT 120 VAC. ELKAY EZSTL8C OR EQUAL. PROVIDE P TRAP AND CENTRAL
FLORIDA
STOP. 0.5" CW. 1.5" TRAP.
3" FD-1: 3" OUTLET FLOOR DRAIN WITH 5" DIA. STRAINER, TRAP PRIMER
CONNECTION, AND CAST IRON BODY. ZURN Z415PNL OR EQUAL. 3" TRAP.
4" FD-1: 4" OUTLET FLOOR DRAIN WITH 5" DIA. STRAINER, TRAP PRIMER
CONNECTION, AND CAST IRON BODY. ZURN Z415PNL OR EQUAL. 4" TRAP.
MS-1: THERMOPLASTIC 24" X 24" X 10" HIGH MOP SINK EQUAL TO FIAT MSB2424.
PROVIDE WITH SPEAKMAN SC-5811-RCP SERVICE FAUCET AND WALL
FCO:
BRACE, AND VACUUM BREAKER. 0.5" CW. 0.5" HW. 3" TRAP.
GALLONS. 23" X 20" AND TOP AT 33.5". 0.5" CW 0.5" HW. 1.5" SAN. PROVIDE
STOPS AND DOME STRAINER.
P3
MECHANICAL ENGINEER
TT-1: TREATMENT TABLE SPECIFIED BY OTHERS WITH INTEGRAL SST SINK, HOSE,
AND FAUCET . 0.5" CW 0.5" HW. 1.5" SAN. PROVIDE STOPS.
A. PETER TANKEL, P.E.
702 DENTON ROAD
TUB-1: TUB FOR BATHING ANIMALS WITH ENTRY RAMP SPECIFIED BY OTHERS WITH WINTER PARK, FL 32792
INTEGRAL FAUCET AND HOSE. 0.5" CW 0.5" HW. 2" SAN. PROVIDE STOPS. PE 41231
WMB-1: WASHING MACHINE BOX. WALL MOUNTED WITH INTEGRAL STOPS, HOSE, P
TRAP, ETC. GUY GREY, OATEY, OR EQUAL. 0.5" CW 0.5" HW. 1.5" SAN
P3.1