PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO.

RL-110 (888-4169) AT WADI AL SAFA 5

PARTICULARCONDITIONS&SPECIFICATIONS FORMRS.MAMTAJHAWAR PROPOSEDRESIDENTIALVILLA(B+G+1)ONPLOTNORL110(8884169) AREAWADIALSAFA5 1. THE CONTRACTOR HAS TO EXECUTE ALL WORKS ACCORDING TO DRAWINGS. GENERAL CONDITIONS AND PARTICULARCONDITIONS,GENERALANDPARTICULARSPECIFICATIONS ALL WORKS AND MATERIALS HAVE TO BE APPROVED BY THE CONSULTANT AND THE CONTRACTOR MUST REMOVEORDISMANTLEANYWORKNOTAPPROVEDBYHIM. THE CONTRACTOR HAS TO VISIT THE SITE TO FIND OUT THE NATURE OF SOIL, LEVELS, AMOUNT OF BACKFILL AND ACCESS ROAD TO THE SITE AREA. THIS SHOULD BE CONSIDERED BEFORE SIGNING THE CONTRACT. OTHERWISE,ITISDEEMEDINCLUDEDTOBRINGTOTHEREQUIREDLEVELANDTOPROVIDEACCESSTOTHESITE. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING IF THE DEWATERING IS NECESSARY. IF SO THIS SHOULD BE CONSIDEREDINHISOFFER. ALL SETS OF DRAWINGS AND SPECIFICATIONS, DULY STAMPED AND SIGNED MUST BE SUBMITTED IN A SEPARATEENVELOPALONGWITHTENDER.TENDERSWITHOUTSAIDDOCUMENTSSHALLNOTBEACCEPTED. ANYDISCREPANCIESBETWEENDRAWINGS,BILLOFQUANTITIESANDSPECIFICATIONSSHOULDBEBROUGHTTO THE CONSULTANTS NOTICE PRIOR TO PRICING THE WORKS. IF NOT DURING THE EXECUTION, FOR THE SUCH DISCREPANCIESCONSULTANTSDECISIONWILLBERULING. BIDDER MUST SUBMIT ALL DETAILS OF QUANTITIES AND UNIT PRICE FOR ALL ITEMS. TENDER WITHOUT SUCH DETAILSISLIABLETOBEREJECTED. CONTRACTOR SHALL SUPPLY AND FIX 2 SETS OF PROJECT BOARDS MENTIONING THE FOLLOWING AND AS PER THEDRAWINGS.

2.

3.

4.

5.

6.

7.

8.

1. 2. 3. 4. 5. 9. THEALLOTTEDTIMEFORTHECOMPLETIONOFTHEPROJECTSHALLBE13(THIRTEEN)MONTHSFROMTHEDATE OF DEMARCATION AND THIS WILL INCLUDE ONEMONTH MOBILIZATION. THERE SHALL BE NO GRACE PERIOD AND A PENALTY OF DHS. 2,000/ PER DAY, PAYABLE TO THE OWNER PLUS A PENALTY OF DHS. 500/ PER DAY, PAYABLETOTHECONSULTANT. BUILDINGPERMITANDPROJECTTYPESIZE2X8. CONSULTANTSPARTICULARSIZE4X8 CONTRACTORSPARTICULARSIZE4X8 2NOS.PERSPECTIVESIZETOBE4X6 CONTRACTORSHALLPROVIDE2NOS.FLOODLIGHTSFOREACHBOARD.

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE 10.1

FINISHING

LOCATION

FLOORS: NO LEVELING OF SAND UNDER TILES IS ALLOWED. ALL THE TILES TO BE LAID ON CONCRETE SCREED AND CEMENT MORTAR AS PER THE ENGINEERSAPPROVAL.ALLTHETILESSHALLBESUPPLIEDANDFIXEDBY THE CONTRACTOR WITH PC RATES (SUPPLY RATE ONLY) OF ITEMS MENTIONED. GRANITYTILESFORAP.C.RATE DHS.45/PERSQ.M. SHALLBESUPPLIED STUDY,GAMES RMATGROUND AND FIXED BY THE CONTRACTOR DESIGN AND PATTERN AS PER ,STORE AT FIRST FLOOR AND BASEMENTAREA CONSULTANTSAPPROVAL. NATURAL MARBLE FOR A P.C.RATE DHS.250/PER SQ.M. SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR, DESIGN AND PATTERN AS PERCONSULTANTSAPPROVAL.
ENTRANCE, STEPS, ENTRANCE LOBBY ,ENTRANCE HALL, DRAWING ROOM, DINING, WASH & TOILET AT GROUNG FLOOR AND FAMILY SITTING , MASTER BEDROOM, ITS DRESS &BATHATFIRSTFLOOR KITCHEN, & ITS WASH AND ALL BEDROOMS, DRESSES & BATHROOMS AT GROUND & FIRSTFLOOR.

10. 1.1

10.1.2

10.1.3

GRANITY TILES FOR A P.C.RATE DHS. 65/PER SQ.M. SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR DESIGN AND PATTERN AS PER CONSULTANTSAPPROVAL.

10.1.4 10.1.5

MOSAIC TILE 30 X 30CM WITH LOCAL MARBLE CHIPPING AS PER ROOFAREAS ENGINEERSAPPROVAL MANGALORE TILES FOR A P.C RATE DHS. 80/PER SQ.MT SHALL BE AS SHOWN ON ELEVATION SUPPLIED AND FIXED BY THE CONTRACTOR, DESIGN AND PATTERN AS DRAWINGS PERCONSULTANTSAPPROVAL. UNGLAZED PORCELIAN FLOOR TILES FOR A P.C RATE DHS. 75/PER AROUND THE VILLAS INSIDE SQ.MT. SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR AS PER THEBOUNDARY ENGINEERSAPPROVAL. 75MM THICK CONCRETE SCREED SMOOTH FINISH WITH ANTI DUST CARGARAGEAREAS LAYERASPERENGINEERSAPPROVAL MARBLESTEPSONEPIECETREAD30MMTHICKWITHNOSINGANDRISER STAIRCASESFROMBASEMENT 20MM THICK FOR A P.C.RATE DHS.250/PER R.M SHALL BE SUPPLIED FLOORTOROOF ANDFIXEDBYCONTRACTORASPERENGINEERSAPPROVAL.
THRESHOLD SHALL BE NATURAL ITALIAN MARBLE 3CM THICKNESS FOR A FOR ALL EXTERNAL DOORS, P.C.RATE DHS. 200/PER RM. SUPPLIED AND FIXED BY THE CONTRACTOR KITCHEN, ALL WASH, BATH AND SHOULD BE FIXED AT 1.5 CM ABOVE FINISHED FLOOR LEVEL AS PER ROOMSANDTOILETDOORS. ENGINEERSAPPROVAL.

10.1.6

10.1.7 10.1.8

10.1.9

10.2 10.2.1

SKIRTING:

MARBLE SKIRTING FOR A P.C.RATE DHS. 75/PER RM 10 CM HIGH ALL AREAS WHERE MARBLE SUPPLIED AND FIXED BY THE CONTRACTOR AS PER ENGINEERS AREUSEDASFLOORING APPROVAL GRANITY SKIRTING FOR A P.C.RATE DHS. 20/PER RM 10 CM HIGH WHERE GRANITY TILES ARE SUPPLIED AND FIXED BY THE CONTRACTOR AS PER ENGINEERS BEINGUSEDASFLOORING APPROVAL WALLFINISHING:

10.2.2

10.3 10.3.1

CERAMIC/GRANITY WALL TILES TO BE FIXED BY GLUE ON DRY WELL PLASTERDSURFACEGROUTFORTILESTOBEMADEOFWATERPROOFAS


2

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE

FINISHING APPROVEDBYENGINEER

LOCATION

10.3.2

NATURAL MARBLE FOR A P.C.RATE.DHS.250/PER SQ.M. SHALL BE TOILET & WASH AT GR. FLOOR SUPPLIED AND FIXED BY THE CONTRACTOR, DESIGN AND PATTERN AS ANDMASTERBATH PERCONSULTANTSAPPROVAL. GRANITY TILE FOR A P.C.RATE DHS. 45/PER SQ.M. SHALL BE SUPPLIED TOILET AT BASEMENT FLOOR ANDMAIDBATH ANDFIXEDBYTHECONTRACTORASPERENGINEERSAPPROVAL. GRANITY TILE FOR A P.C.RATE DHS.65/PER SQ.M. SHALL BE SUPPLIED KITCHEN & ITS WASH AT GR. FLOOR, ALL BATHROOMS AT ANDFIXEDBYTHECONTRACTORASPERENGINEERSAPPROVAL.
FIRST FLOOR AND BALCONIES&TERRACES. ALL

10.3.3 10.3.4

10.3.5

EPOXY PAINT TO BE EPOXY (NONACRYLIC) (JOTUN) OR APPROVED EQUIVALENT SPRAY APPLIED WITH GUN IN FOUR COATS ON SMOOTH FINISHED PLASTERS WITHOUT ANY UNDULATIONS TO ENGINEERS APPROVALINFOLLOWINGSTEPS: A) UNDERCOATASSEALER B) TEXTUREEPOXYLAYER. C) (2) FINAL COATS OF POLYURETHANE) TEXTURES TO THE APPROVALOFARCHITECT.

ALL EXTERNAL WALLS OF VILLA, BOUNDARY WALLS FROM INSIDE AND OUTSIDE WHERE THERE IS NO STONE FINISHINGISSHOWN.

10.3.6

SEALLER + PUTTY + 3 COATS OF FENOMASTIC EMULSION PAINT (JOTUN) ALL INTERNAL WALLS OF ON WELL PLASTERED DRY WALL AS PER SPECIFICATIONS AND VILLAS WHERE NO TILE FINISHESAREMENTIONED. ENGINEERSAPPROVAL. NATURAL STONE FINISH FOR A P.C.RATE.DHS.200/PER SQ.M.SHALL BE ALL AREAS AS SHOWN IN THE SUPPLIED AND FIXED BY THE CONTRACTOR, DESIGN AND PATTERN AS ELEVATIONDRAWINGS PERCONSULTANTSAPPROVAL. NATURAL RED CLAY ROOF TILES SHALL BE SUPPLIED AND FIXED BY THE ALL AREAS AS SHOWN IN THE CONTRACTOR,DESIGNANDPATTERNASPERCONSULTANTSAPPROVAL. ELEVATION&DRAWINGS CEILINGFINISHES.

10.3.7

10.3.7 10.4 10.4.1

SPRAY PLASTER TECHNIQUE FOR CEILING WITH PAINT FINISH FROM HI IN ALL AREAS WHERE THERE TECH OR APPROVED SUPPLIER AND COLOUR AND TEXTURE AS PER ISNOFALSECEILING ENGINEERSAPPROVAL. SEALLER + PUTTY + 3 COATS OF FENOMASTIC EMULSION PAINT (JOTUN) ALL AREAS WHERE GYPSUM ONWELLFINISHEDGYPSUMBOARDCEILINGWITHBULKHEADS BOARD CEILING ARE SHOWN INTHECEILINGDWGS. GYPSUM TILES FALSE CEILING 60 X 60 CM WITH VINYL BASE FROM BACK ALL CEILING OF WET AREAS AS PER ENGINEERS APPROVAL OR ALUMINUM BACKING FOR WET SUCH AS KITCHEN, TOILET AREAS AND ALL BATHROOMS AS SHOWN IN THE CEILING DWGS. GYPSUM BOARD WITH BULK HEAD FALSE CEILING SHALL BE PROVIDED ALL AREAS AS SHOWN IN THE AS PER CONSULTANTS APPROVAL FOR ALL AREAS AS SHOWN IN CEILINGDRAWINGS. DRAWINGS.PAINTEDWITHFENOMASTICPAINTASPERCLAUSE10.4.2 GYPSUM BOARD PLAIN CEILING SHALL BE PROVIDED AS PER ALL AREAS AS SHOWN IN THE CONSULTANTS APPROVAL FOR ALL AREAS AS SHOWN IN THE CEILINGDRAWINGS. DRAWINGS. FALSE CEILING FOR ABOVE AREAS SHALL BE SUPPLY AND FIX BY THE CONTRACTORWITHAPROVISONALSUMOFDHS.75,000/=FORALL.
3

10.4.2

10.4.3

10.4.4

10.4.5

10.4.6

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE 10.5

FINISHING

LOCATION

CARPENTRYANDJOINERY: ALL WOOD WORKS USED TO BE FREE FROM HUMIDITY AND DEFECTS. ALL WOODS TO BE USED STEAM BEACH SUBCONTRACTOR FOR ALL WOODENWORKSASPERENGINEERSAPPROVAL CONTRACTOR SHALL SUPPLY AND FIX ALL WOODEN DOORS (INTERNAL DESIGN AND PATTERN AS PER AND EXTERNAL WOODEN DOORS) FOR A PROVISIONAL SUM OF DHS. CONSULTANTSAPPROVAL 60,000/=TYPE,COLOURSHALLBEASPERCONSULTANTSAPPROVAL. ALL DOORS SHALL HAVE FIXTURES APPROVED QUALITY COST OF LOCK SHALLBEDHS.150/PERDOOR(AVERAGE)ANDMAINDOORLOCKSHALL BEDHS.400/=PERDOOR CONTRACTOR SHALL SUPPLY AND FIX WOODEN PERGOLAS AS SHOWN ON ELEVATION & DRAWINGS FOR A PROVISIONAL SUM OF DHS.25,000/= METALWORKS:

10.5.1

10.5.2

10.5.3

10.6 10.6.1

SUPPLY, INSTALL AND MAINTAIN ALUMINUM DOORS AND WINDOWS MANUFACTUREDBYM/S.GULFEXTRUSIONFACTORY(JEBELALI)ANDTO BEFIXEDBYAPPROVEDSUBCONTRACTORBYENGINEER.BEIGECOLOUR MULLION, TRANSOMS, SILLS LUGS, WEATHER STRIPS, FLY SCREENS, SELANTS,HARDWARE,GLAZINGSTRIPSANDGLAZINGASPERDRAWINGS ANDSPECIFICATIONS. ALLWINDOWSSHALLBEDOUBLEGLAZEDASFOLLOWS: 6MMREFLECTIVEBELGIUMMAKE70% 12MMAIRGAP 6MM CLEAR GLASS AND AS PER CLAUSE GENERAL SPECIFICATIONS. AND ASPERARCHITECTURALDRAWINGS. ALLGLAZINGTOBATHROOMSTOBE: 6MMOBSCUREDGLASSSHEET.

10.6.2

10.6.3 10.6.4 10.6.5

ALUMINUM SECTION TO BE AS GULF EXTRUSION AND SECTIONS SHALL ALL ALUMINUM WINDOWS BEASSHOWNINTHEDRAWINGS. ANDDOORS ALL ALUMINUM AND GLASS WORK TO BE TESTED AGAINST LEAKAGE BY PRESSURED WATER PRIOR TO OVER CONTRACTOR TO ARRANGE FOR SUCH TEST IN PRESENCE OF OWNER AND CONSULTANT. THE SYSTEM MUSTBEPERFECTLYSEALEDAGAINSTLEAKINGANDWHISLTINGANDTO RESISTWINDPRESSURE. ALL ALUMINUM WORKS SHALL BE EXECUTED BY A SPECIALIZED APPROVED SUB CONTRACTOR WITH A MINIMUM EXPERIENCE OF 5 YEARSANDSUBJECTEDTOCONSULTANTSAPPROVAL. ELECTRICALWORKS:

10.6.6

10.7

ALL ELECTRICAL WORKS SHALL BE EXECUTED BY SPECIALIZED SUB CONTRACTOR WITH A MINIMUM EXPERIENCE OF 5 YEARS AND SUBJECTED TO CONSULTANTS APPROVAL. AND WORKS SHALL BE EXECUTED AS PER LATEST RULES AND REGULATIONS OF DEWA. ALL MATERIALS SUCH AS CONDUITES,GIBOXES,SWITCHSOCKETS,SHALLBEUKMAKEORAPPROVED EQUIVALENT AND WIRES, CABLE SHALL BE AS PER DEWA STANDARDS AND AS PER CONSULTANTS APPROVAL, AND ALL SHOP DRAWINGS AND MATERIALS SHALL BE SUBMITTED FOR CONSULTANTS APPROVAL PRIOR TO EXECUTEANDUSEONTHESITE.

10.7.1

LIGHTFIXTURES:
4

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE

FINISHING ALLLIGHTFITTINGSSHALLBESUPPLIEDANDFIXEDBYTHECONTRACTOR WITHAP.C.RATEOFDHS.100/=PERPOINT.

LOCATION

10.7.2

TELEPHONEANDDATACABLINGWORKS.

ALL WORKS FOR TELEPHONE, FAX, AND FOR DATA AND LOW CURRENT NETWORK AS PER DU TELEPHONE RULES AND REGULATIONS REFER ATTACHED RULES AND REGULATIONS OF TELECOMMUNICATIONS AND INFRASTRUCTURE. SHALL BE SUPPLY AN FIX BY CONTRACTING BY APPOINTING LISTED APPROVED SUB CONTRACTOR BY DU TELEPHONE AUTHORITIES. ALL CIVIL & ELECTRICAL COORDINATION SHALL BE PROVIDED BYCONTRACTORTOAPPOINTEDSUBCONTRACTOR

10.7.3

WATERHEATERS: 16 GAL. CAPACITY AND WHITE COLOR ARISTON (GLASS LINED) (HORIZONTAL WITH BUILT IN KITCHEN BATHROOMS EARTHINGCONDUCTORS(ABOVEFALSECEILING)

FOR ALL

10.7.4

CONTRACTOR SHALL CARRY OUT ALL BUILDERS WORK CONDUIT WORK FOR POWER AND THERMOSTATS, PIPING WORK FOR DRAINAGE NEAR A.C UNITS ETC., WHICH ARE NOT INCLUDED IN A.C. SUBCONTRACTORS WORK. A.CWORKS: AIR CONDITIONING SYSTEM SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR WITH THE PROVISIONAL SUM OF DHS.175,000/= CONTRACTOR TO PREPARE CONCRETE BASE ON ROOF PROVIDED P.V.C SLEEVES PROVIDED DRAINAGE WITH 1 PVC PIPE OR AS REQUESTED BY THEMECHANICALSUBCONTRACTORTOTHENEARESTDRAINPOINT.

10.8

10.8.1

POWER SUPPLY TO THE FAN COIL UNITS, WITH W.P. TPN ISOLATOR OF APPROPRIATE SIZES OR AS PER ENGINEERS APPROVAL TO BE DONE BY THECONTRACTORASPERDRAWINGSANDSPECIFICATION. ALL CIVIL AND PLUMBING WORKS RELATED TO A.C TO BE CONSIDERED BYTHECONTRACTORANDTOBEDONEBYTHECONTRACTOR.

10.8.2

10.9

SANITARYWORKS: THE SUBCONTRACTOR FOR PLUMBING WORKS TO BE AS PER CONSULTANTS APPROVAL AND APPROVED MEP SUB CONTRACTOR WITHMINIMUM5YEARSOFEXPERIENCE.

10.9.1

ALL BATH ROOMS AND TOILETS SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR WITH THE PROVISIONAL SUM OF DHS. 80,000/= INCLUDINGACCESSORIESANDFITTINGS. FLOOR TRAP TO BE PROVIDED FOR BALCONIES/ TERRACES AND CONNECTEDTOTHEDRAINAGESYSTEMASPERENGINEERSAPPROVAL. MANHOLEWITHCOVERCASTIRONHEAVYDUTYASPERTHEENGINEERS APPROVAL. TYPE1DOUBLESEALRECESSEDTORECEIVEFLOORFINISH. TYPEIIDOUBLESEAL

10.9.2 10.9.3 10.9.4 10.9.5 10.9.6

ALL DRAINAGE PIPES SHALL BE TERRAIN OR HEPWORTH OR EQUIVALENT APPROVED BY CONSULTANT, AND ALL INTERNAL WATER SUPPLY SYSTEM SHALLBEUSINGPEXSYSTEMFROMM/SJUMAALMAJIDOREQUIVALENTAS PERCONSULTANTSAPPROVAL.

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE 10.9.7

FINISHING

LOCATION

CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWING FOR WATER SUPPLY NET WORK AND DRAINAGE LAYOUT TO THE CONSULTANTS APPROVAL,PRIORTOWORKONSITE.
ALL EXPOSED U.P.V.C PIPES SHOULD BE PROTECTED WITH TWO COATS OF EPOXYSUITABLETORESISTULTRAVIOLETRAYS.ANDALLOVERHEADWATER TANKS SHALL BE TRIPLE LAYER INSULATED FROM POLYCON AND CAPACITY SHALLBEPERDRAWINGS.ANDUNDERGROUNDWATERTANKSHALLBERCC WITH GRP LINING AS PER CONSULTANTS APPROVAL AND CAPACITY AS SHOWNINTHEDRAWINGS.

10.9.8

10.10

WATERPROOFING:

BASEMENT, ROOF & ALL WATER PROOFING LAYERS SHOULD BE CARRIED OUT BY M/S.DESERT EXPOSEDTERRACES.

ROOFING COMPANY USING INDEX TESTUDO (4MM) REINFORCED TORCH APPLIED MEMBRANE WITH 10 YEARS GUARANTEE ROOF TO BE TESTED FOR AT LEAST 48 HOURS AGAINST LEAKING OVERLAPPING SHALL BE 200MM HEIGHT WATER PROOFING SKIRTING AROUND THE ROOF PARAPET AS SHOWNINTHEDRAWINGS.

10.10.1

FOR ALL SUB STRUCTURE WORKS TWO COATS OF COLD BITUMEN SUBSTRUCTURE (LAVATEX2000)SHALLBEPAINTEDASPERENGINEERSAPPROVAL FORALLSUBSTRUCTUREWORKS6MMTHICKPROTECTIONBOARDSHALL
BEPROVIDEDASPERCONSULTANTSAPPROVAL PROVIDEDONTHEROOFASPERENGINEERSAPPROVAL.

10.10.2 10.10.3 10.10.4

SUBSTRUCTURE

5 CM THICK HEAT INSULATION BOARD (ROOF MASTER) SHALL BE DAMP PROOF COURSE (DPC) TO BE PROVIDED FOR THE TIE BEAM LAYER FOR ALL BLOCK WORKS AT ROOMFROMINDEXSIRIOORDEFENDOREQUIVALENT.JOINTSSHALLBE GROUNDFLOORLEVEL. 100MMOVERLAPPING. EXPANSIONJOINTS: 2CMTHICKEXPANSIONJOINTWITHFILLERBOARD(FIBREPAKSERVICED, FIBERFILL FEB OR EQUIVALENT) BITUMEN LAYER IN BETWEEN AND TOP FINISHED AS VERTICAL SEALANT (VERTISEAL, THYOFLEX 600 FIBSEAL) OR ROOFANDEXPANSIONJOINT AS HORIZONTAL SEALANT (PARASEAL) COLPAR 200, FEBSEAL. AND WITH

10.11

EXPANSIONCOVERASPERENGINEERSAPPROVAL.

10.12

BLOCKWORK: ALL SOLID AND HOLLOW CONCRETE BLOCK WORK FROM APPROVED MECHANICAL FACTORY, M/S JUMA AL MAJID, M/S. EMCON, M/S.DAFCO OREQUALAPPROVED.

10.12.1 10.12.2

ALL BLOCK WORK BELOW GROUND FLOOR TO BE OF READY MADE SOLIDBLOCKWORK. ALL EXTERNAL BLOCK WORK SHALL BE 10 THICK INSULATED CONCRETE BLOCKS FROM EMCON OR EQUIVALENT AS PER DM LATEST RULES AND REGULATIONSTOBEFASTENEDTOCONCRETESTRUCTUREBYBRASSOR STAINLESS STEEL DOWELS AT EACH 3RD COURSE OF BLOCK WORK AS PERENGINEERSINSTRUCTIONS. FIRST COURSE OF BLOCK WORK TO CONCRETE SLAB TO BE OF SOLID BLOCKATALLFLOORLEVELS. ALL BLOCK WORK TO BE PROPERLY GROUTED LEVELED AND PLUMBED TOTHEENGINEERSSATISFACTION. BLOCK WORK AROUND WINDOWS AND DOORS TO BE SOLID BLOCK
6

10.12.3 10.12.4 10.12.5

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE

FINISHING WORKS.

LOCATION

10.13

CONCRETEWORK: THE STRUCTURAL DRAWING IS TO READ IN CONJUNCTION WITH THE ARCHITECTURALDRAWING.

10.13.1

THE MINIMUM DEPTH OF FOUNDATIONS MUST BE AS MENTIONED IN DRAWINGS FROM PROPOSED AVERAGE GROUND LEVEL UNLESS OTHERWISE SPECIFIED IN THE DRAWING OR RECOMMENDED IN THE SOIL INVESTIGATIONREPORT. LIGHT WEIGHT CONCRETE(FOAM CONCRETE) WITH DENSITY FROM 500 600 KG/M3 AND AVERAGE THICKNESS (10 CM) SHALL BE LAID IN PANEL OFSIZE16M2. CONCRETEMIXSHALLBEASFOLLOWS;

10.13.2

10.13.3 10.13.4 10.13.5

PCC FOR BLINDING 1:3:6 BY VOLUME WITH A MINIMUM CRUSHING STRENGTH2300lb/SqINCH(160KG/CM2)AFTER28DAYS. PCC FOR ROOM FLOORING SHALL BE 1:2:4 BY VOLUME WITH A MINIMUM CRUSHING STRENGTH OF 4300 lb/Sq INCH (300 KG CM2) AFTER28DAYS. RCC FOR FOOTING, BEAMS, AND SLABS ETC SHALL BE WITH MINIMUM REFER STRUCTURAL CEMENT CONTENT 370 KG/M3 AND A MINIMUM CRUSHING STRENGTH DRAWINGSANDNOTES. 35N/MM2 OF UNLESS OTHERWISE SPECIFIED DESIGN MIX SHOULD BE SUBMITTEDFORAPPROVAL,BEFORETHECOMMENCEMENTOFWORK. FOR SPECIFICATION OF AGGREGATES FOR CONCRETE MIX REFER TO THE ATTACHEDSHEETS. ALL FORMS FOR CONCRETE TO BE FAIR FACE MARINE PLYWOOD FORMS ALL CONCRETE TO BE CARRIED BY A APPROVED READY MIX PLANT OR FACTORY ALL STEELSHALL BEOF TURKEY ORGIN, HYSD BARSE CONFIRMING TO BS 4449 OR ASTMA 615 GRADES 60. STEEL SHALL BE FRESH AND NEWLY LOADED@THETIMEOFDELIVERYTOTHESITE. MINIMUMDEPTHOFLINTELSHOULDBE30CM.

10.13.6

10.13.7 10.13.8. 10.13.9 10.13.10

10.13.11 10.13.12

ALL FACES OF CONCRETE IN CONTACT WITH SOIL TO BE TREATED WITH TWOCOATSOFCOLDBITUMINOUSPAINT(LAVATEX2000). ALLSEASANDFORCONCRETEORPLASTERWORKTOBEWASHEDASPER ENGINEERSAPPROVAL. ALLGRAVELFORCONCRETEWORKTOBEFROMAPPROVEDQUARRY.

10.13.13 10.13.14 10.14.

MISCELLANEOUS: KITCHEN AND PANTRY CABINETS SUPPLIED AND FIXED BY THE CONTRACTOR WITH THE PROVISIONAL SUM OF DHS. 60,000/=INCLUDING STAINLESS STEEL SINK SINGLE BOWL (UK MAKE) WITH GROHEE MIXERS, CONTRACTORS HAS TO PROVIDE ALL CIVIL WORKSANDELECTROMECHANICALWORKSNEEDED.

EMSQUARE ENGG. CONSULTANT

PROJECT: PROPOSED RESIDENTIAL VILLA (B+G+1) ON PLOT NO. RL-110 (888-4169) AT WADI AL SAFA 5

CLAUSE 10.14.1

FINISHING

LOCATION

6 DIA SPIRAL ALUMINIUM LADDER 1 NO. FROM GROUND FLOOR TO ROOF SHALL BE SUPPLIED AND FIXED BY THE CONTRACTOR AS PER CONSULTANTSAPPROVAL. CONSIDER PROVISIONAL SUM OF DHS 135,000/ FOR PASSENGER LIFT SHALL INCLUDE HOISTING EQUIPMENT, ELEVATOR CAR WITH INTERIOR AND FLOOR FINISH, WALL AND CEILING FINISH AS DETAILED IN DRAWINGSASPERCONSULTANTSAPPROVAL. CONTRACTOR SHALL SUPPLY AND FIX METAL RAILING FOR STAIRCASE FOR PC RATE OF DHS. 800/PER RM AND FOR BALCONIES & TERRACES DHS. 600/ PER RM, AREAS AS SHOWN IN DRAWINGS COLOUR, DESIGN SHALLBEASPERENGINEERSAPPROVAL. CONTRACTOR SHALL SUPPLY AND FIX WOODEN WARDROBES FOR PROVISIONAL SUM OF DHS. 60,000/= INCLUDING LOCKS, HINGES, HANDLES&ACCESSORIES. CONTRACTOR SHALL SUPPLY AND FIX WINDOW SILLS WITH 30 MM THICK ITALIAN MARBLE OF FULL WIDTH AS PER CONSULTANTS APPROVAL. TELEVISIONANTENNAS: SUPPLY, INSTALL AND CONNECT CENTRAL T.V. ANTENNA SYSTEM AND DUCTSYSTEMFORLUMPSUMPRICEOFDHS.5,000/=EQUIPMENTCOST CONTRACTOR HAS TO DO ALL RELATED WORKS (CIVIL & ELECTRICAL) AS PERMEPDRAWINGSANDSPECIFICATIONS.

10.14.2

10.14.3

10.14.4

10.14.5

10.14.6

10.14.7

LANDSCAPING CONSIDER PROVISIONAL SUM OF DHS. 40,000/= FOR SOFT SCAPING & HARDSCAPING AND CONTRACTOR SHALL CARRY OUT COORDINATION, ALL RELATED CIVIL & ELECTROMECHANICAL WORKS ALSO INCLUDING SUPPLYOFSWEETSOIL.

10.14.8

PEDESTRIAN&CARGARAGEGATE OWNER SHALL SUPPLY AND FIX ALL GATES FOR PEDESTRIAN, AND CAR GATEASPERENGINEERSAPPROVAL.

10.14.9

CONTRACTOR TO CONSTRUCT SEPARATE MANHOLES, WITH SEPARATE SYSTEM FOR A/C DRAIN WATER AS SHOWN ON THE A/C DRAIN LAYOUT DRAWINGS. AND SHALL BE CONNECTED TO UNDER GROUND WATER TANK CONTRACTOR SHALL SUPPLY AND FIX GRC ELEMENTS & WORKS AS SHOWN ON ELEVATION & DRAWINGS FOR A PROVISIONAL SUM OF DHS.50,000/=

10.14.10

IMPORTANTNOTE: ALLTHETENDERERSHOULDSUBMITTEDDETAILEDBILLOFQUANTITIES,INCOMPLETESUMMARYSHEETSHALLNOTBECONSIDERED.