Three Phase Central Lighting Inverters 10-30KVA

Features

TRX

AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, HID, fluorescent, and LED lamps Painted steel, small footprint enclosure and double conversion online operation Maintenance-free batteries with fully automatic solid state charger Factory startup standard Temperature range: 20C to 30C (68F to 86F) UL 924 Listed

i n v e rt e r s Ordering Information

TRX
Model TRX INPUT VoltaGE 208 208V 480 480V 600 600V input conductor 3 3 Wire 4 4 Wire capacity 10 10KVA 15 15KVA 20 20KVA 30 30KVA output voltage1 208 208V 480 480V 600 600V options RSP SFK EXP FWT FTR OWC 485
1 2

Output voltage must equal input voltage Circuit breakers are standard with all configurations except 208/208 4-conductor; must order MBS to obtain circuit breakers for this configuration. External MBS comes standard with I/O circuit breakers.

IRB MBS

Remote Status Panel Seismic Floor Kit Export Package Factory Witness Testing Certified Factory Test Report Open Communications Web Card Open communications 485 Web Card Intel Slot Relay Board External Maintenance Bypass Switch2

Electronics

Uninterruptible "no break" transfer Microprocessor controlled pulse width modulation (PWM) using IGBT technology Transient surge, LVD, short-circuit, current limiting, overload and brown-out protection True sine wave output; optional runtime available Digital controls with graphic user interface with LED indicators and audible alarm system Load power factor range of .95 lead to .70 lag Internal power factor of .80 to yield KW rating

10 KVA Models

15 and 20 KVA Models

30 KVA Models

63"

51"

83"

142"

992

Three Phase Central Lighting Inverters 10-30KVA


specifications
system rating KVA KW AC Voltage1 Input Output Nom. AC Input current Max OCPD Nom. VDC Battery KW Max. Discharge AC Ouput current Nom. OCPD Weight lbs. (kg) Heat Dis. BTU/ hr (KWH)

TRX
2,800 (0.82) 4,200 (1.23) 5,500 (1.61) 8,300 (2.43)

10 15 20 30

8 12 16 24

208 208 208 208

208 208 208 208

28 42 56 83

35 53 70 104 2,3,4

50 60 80 125

288 288 288 28

9 13 18 26

37A 55A 73A 110A 2,3,4

28 42 56 83 2,3,4

50 80 80 125 5

3,070 (1,393) 3,970 (1,801) 4,870 (2,209) 7,170 (3,253)

i n v e rt e r s

See Notes for Table (below):

Notes for Table

1. Contact factory for 480 VAC applications. 2. UPS input and bypass cables must be run in separate conduit from output cables. 3. Wiring requirements: AC Input: 3-phase, 4-wire, plus ground AC Output: 3-phase, 3- or 4-wire, plus ground 4. Control wiring and power wiring must be run in separate conduit. 5. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace.