Vous êtes sur la page 1sur 5

----------------------------------------------------------------------------------------------------------------------------------------------------COMMAND OUTPUT

----------------------------------------------------------------------------------------------------------------------------------------------------1)
[nasadmin@NS20-MSS log]$ nas_inventory -list
Component
Type
System ID
Battery A
Battery
CLARiiON CX3-10 APM00073500036
Battery B
Battery
CLARiiON CX3-10 APM00073500036
Celerra NS20 APM000735000360000
Celerra
Celerra NS20 APM000735000360000
CLARiiON CX3-10 APM00073500036
CLARiiON
CLARiiON CX3-10 APM00073500036
Control Station 0
Control Station
Celerra NS20 APM000735000360000
DME 0 Data Mover 2
Data Mover
Celerra NS20 APM000735000360000
DME 0 Data Mover 2 Ethernet Module
Module
Celerra NS20 APM000735000360000
DME 0 Data Mover 2 SFP BE0
SFP
Celerra NS20 APM000735000360000
DME 0 Data Mover 2 SFP BE1
SFP
Celerra NS20 APM000735000360000
DME 0 Data Mover 2 SFP FE0
SFP
Celerra NS20 APM000735000360000
DME 0 DME 0
Enclosure
Celerra NS20 APM000735000360000
DME 0 Management Switch A
Management Switch
Celerra NS20 APM000735000360000
DME 0 psFan A
psFan
Celerra NS20 APM000735000360000
DME 0 psFan B
psFan
Celerra NS20 APM000735000360000
Power Supply A0
Power Supply
CLARiiON CX3-10 APM00073500036
Power Supply A1
Power Supply
CLARiiON CX3-10 APM00073500036
Power Supply B0
Power Supply
CLARiiON CX3-10 APM00073500036
Power Supply B1
Power Supply
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 0
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 1
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 2
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 3
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 4
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Disk 5
Disk
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Fan A
Fan

Status
OK
Optional
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK

CLARiiON CX3-10 APM00073500036


Shelf 0/0 Fan B
Fan
OK
CLARiiON CX3-10 APM00073500036
Shelf 0/0 LCC A
LCC
OK
CLARiiON CX3-10 APM00073500036
Shelf 0/0 LCC B
LCC
OK
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Power Supply A
Power Supply
OK
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Power Supply B
Power Supply
OK
CLARiiON CX3-10 APM00073500036
Shelf 0/0 Shelf 0/0
Enclosure
OK
CLARiiON CX3-10 APM00073500036
SP A
SP
OK
CLARiiON CX3-10 APM00073500036
SP B
SP
OK
CLARiiON CX3-10 APM00073500036
Write Cache
Cache
OK
CLARiiON CX3-10 APM00073500036
---------------------------------------------------------------------------------------------------------------------------------------------------------------2)
[nasadmin@NS20-MSS log]$ nas_inventory -list -location
Component
Type
Status
System ID
Location
Battery A
Battery
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|sps::A
Battery B
Battery
Optional
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|sps::B
Celerra NS20 APM000735000360000
Celerra
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000
CLARiiON CX3-10 APM00073500036
CLARiiON
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036
Control Station 0
Control Station
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|contr
olStation::0
DME 0 Data Mover 2
Data Mover
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mover:NS20:2
DME 0 Data Mover 2 Ethernet Module
Module
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mover:NS20:2|module:ethernet:
DME 0 Data Mover 2 SFP BE0
SFP
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mover:NS20:2|sfp::BE0
DME 0 Data Mover 2 SFP BE1
SFP
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mover:NS20:2|sfp::BE1
DME 0 Data Mover 2 SFP FE0
SFP
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mover:NS20:2|sfp::FE0
DME 0 DME 0
Enclosure
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0

DME 0 Management Switch A


Management Switch
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|mgmtSwitch::A
DME 0 psFan A
psFan
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|psFan::A
DME 0 psFan B
psFan
OK
Celerra NS20 APM000735000360000
system:NS20:APM000735000360000|enclo
sure:xpe:0|psFan::B
Power Supply A0
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|ps::A0
Power Supply A1
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|ps::A1
Power Supply B0
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|ps::B0
Power Supply B1
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|ps::B1
Shelf 0/0 Disk 0
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::0
Shelf 0/0 Disk 1
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::1
Shelf 0/0 Disk 2
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::2
Shelf 0/0 Disk 3
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::3
Shelf 0/0 Disk 4
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::4
Shelf 0/0 Disk 5
Disk
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|pdisk::5
Shelf 0/0 Fan A
Fan
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|fan::A
Shelf 0/0 Fan B
Fan
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|fan::B
Shelf 0/0 LCC A
LCC
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|lcc::A
Shelf 0/0 LCC B
LCC
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|lcc::B
Shelf 0/0 Power Supply A
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|ps::A
Shelf 0/0 Power Supply B
Power Supply
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0|ps::B
Shelf 0/0 Shelf 0/0
Enclosure
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|enclosure:katana:0/0

SP A

SP
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|sp::A
SP B
SP
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|sp::B
Write Cache
Cache
OK
CLARiiON CX3-10 APM00073500036
system:NS20:APM000735000360000|clari
ionSystem:CX3-10:APM00073500036|cache:write:
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------3)
[nasadmin@NS20-MSS log]$ nas_inventory -info "system:NS20:APM000735000360000|enc
losure:xpe:0|mover:NS20:2"
Location
= system:NS20:APM000735000360000|enclosure:xpe:0|mover:NS20:2
Component Name = DME 0 Data Mover 2
Type
= Data Mover
Status
= OK
Variant
= NS20
Version
= T5.6.48.7,BIOS_VERSION="03.80",POST_VERSION="Rev. 01.59"
Serial Number = CF2TS073400181
Part Number
= 100-562-150
History
= EMC_PART_NUMBER:100-562-150
EMC_ARTWORK_REVISION:
EMC_ASSEMBLY_REVISION:A01
EMC_SERIAL_NUMBER:CF2TS073400181
VENDOR_NAME:CELESTICA
LOCATION_OF_MANUFACTURE:THAILAND
YEAR_OF_MANUFACTURE:2007
MONTH_OF_MANUFACTURE:8
DAY_OF_MONTH_OF_MANUFACTURE:22
ASSEMBLY_NAME:NS3-40 CU NAS
----------------------------------------------------------------------------------------------------------------------------------------------------------------------4)
[nasadmin@NS20-MSS log]$ nas_inventory -info "system:NS20:APM000735000360000|cla
riionSystem:CX3-10:APM00073500036|sps::A"
Location
= system:NS20:APM000735000360000|clariionSystem:CX3-10:APM0007350
0036|sps::A
Component Name = Battery A
Type
= Battery
Status
= OK
Variant
= Standby Power Supply
Storage System = CLARiiON CX3-10 APM00073500036
Serial Number = AC105030903935
Part Number
= 118031985
History
= EMC_PART_NUMBER:118031985
EMC_ARTWORK_REVISION:N/A
EMC_ASSEMBLY_REVISION:A06
EMC_SERIAL_NUMBER:AC105030903935
VENDER_PART_NUMBER:API-1FS18
VENDER_ARTWORK_NUMBER:N/A
VENDER_ASSEMBLY_NUMBER:N/A
VENDER_SERIAL_NUMBER:N/A

VENDOR_NAME:Acbel
LOCATION_OF_MANUFACTURE:N/A
YEAR_OF_MANUFACTURE:N/A
MONTH_OF_MANUFACTURE:N/A
DAY_OF_MONTH_OF_MANUFACTURE:N/A
ASSEMBLY_NAME:Standby Power Supply
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------5)
[nasadmin@NS20-MSS log]$nas_server -list
1=nas, 2=unused, 3=unused, 4=standby, 5=unused, 6=rdf
id
1
2

type acl slot groupID state name


1
0
2
0
4
0
3
0

server_2
server_3

Vous aimerez peut-être aussi