Vous êtes sur la page 1sur 28

PRINCIPLE OF GENERATOR

D.C and A.C


CURRENT

D.C
TIME

BATTERY + CURRENT

CURRENT single-phase

A.C
TIME

OUTLET

U(R) V(S) W(T)


three-phase

A.C EFFECTIVE VALUE


VOLTAGE peak value effective value

TIME

effective value (V) = = =

peak value (V) 2 1411.41 100 (V) 2=1.41

FREQUENCY
A.C

TIME

1 cycle

50Hz = 1cycle50sec 60Hz = 1cycle60sec

FREQUENCY JAPAN

OSAKA TOKYO

ELECTRIC SHOCK

Before working, electric circuit OFF !

100mA(0.1A)3sec 1000mA(1A)0.03sec

PRINCIPLE OF GENERATION

coil

lamp

flux

moving

iron

PRINCIPLE OF ELECTROMAGNET

ELECTRIC WIRE IRON S

BATTERY(D.C)

A. C. GENERATOR OUTLINE

COMPOSITION OF GENERATOR
GENERATOR PARTS
ROTOR PART
SHAFT BALL BEARING ROTATING RECTIFIER ARMATURE CORE FOR EXCITER ARMATURE COIL FOR EXCITER ROTOR CORE ROTOR COIL FAN COUPLING PLATE

STATOR PART
FIELD CORE FOR EXCITER FIELD COIL FOR EXCITER STATOR CORE STATOR COIL FRAME END BRACKET

SELF EXCITER PART


AUTOMATIC VOLTAGE REGULATOR VOLTAGE REGULATOR (HAND TRIMMER)

COMPOSITION PARTS OF GENERATORROTOR

COMPOSITION PARTS OF GENERATORSTATOR

SECTIONAL DRAWING OF GENERATOR


FIELD COIL FOR EXCITER END BRACKET STATOR CORE ARMATURE COIL FOR EXCITER ROTOR CORE FIELD CORE FOR STATOR COIL EXCITER FRAME FAN

COUPLING PLATE

SHAFT
BALL BEARING ROTOR COIL

ROTATING RECTIFIER

ARMATURE CORE FOR EXCITER

COIL & MAGNET N/S POLE ON THE SECTION OF GENERATOR


FIELD COIL FIELD CORE ARMATURE COIL ARMATURE CORE MAGNETIC FLUX

Section

FUNCTIONS OF EACH PART OF GENERATOR STATOR


STATOR FRAME STATOR CORE STATOR WINDING

OUTER CASE

SILICON STEEL PLATES

ELECTRIC WIRES

SUPPLY ELECTRICITY THROUGH LEAD WIRES

ROTOR
ROTOR CORE ROTOR WINDING

RECEIVE DC CURRENT AND PRODUCE MAGNETIC FIELD

STATOR WINDINGS CUT MAGNETIC FLUX TO PRODUCE ELECTLICITY

AC EXCITER
SUPPLYING EXCITATION CURRENT TO ROTOR

ROTATING RECTIFIER
CHANGE AC EXCITATION CURRENT TO DC

DC EXCITATION CURRENT TO ROTOR

VENTILATION FAN
ELECTRIC CURRENT INSIDE GENERATOR

HEAT UP

COOLING FAN

SELF EXCITER PARTS


AVR
AUTOMATIC VOLTAGE REGULATOR

HT

EXTERNAL VOLTAGE ADJUSTER

SELF EXCITER PARTS

NAME PLATE

KNOB

LOCATION
AVR HT Electric power

LOAD

SYSTEM FLOW OF GENERATOR


LOAD

AVR
D.C

SENSING POWER

A.C A.C

OUT PUT A.C

FIELD FOR EXCITER


FLUX A.C D.C

ARMATURE
FLUX

ARMATURE FOR EXCITER

ROTATING RECTIFIER

ROTOR

EXCITER PART GENERATOR

MAIN PART

INSULATION CLASS OF MATERIAL -1


Maximum temperature () .

Class

Example:class F ) 155 145 ()

A E B F H 105 120 130 155 180 ()


details spare 10() rise T=105() ambient 40()

40 0

INSULATION CLASS OF MATERIAL -2


Maximum permissible temperature rise() based on an ambient temperature of 40.

Class T() =

A 60

E 75

80 105 125

USEFUL ELECTRICAL TERMS


VA kVA kW Phase -the products of volt times amperes -1000 Volt Amperes (VA) -unit of electric power (active power), equal to 1000 watts

-The windings of an AC generator. In a three-phase generator, there are three kind of windings with their voltages 120 degrees out of phase. Efficiency -the ratio between electrical output divided by the mechanical input, expressed as a percentage of
Efficiency (%) = Speed Poles Frequency (Hz) = 120 , Speed (min-1) =

kW output
HP input / 0.746

100

1HP=0.746kW

Frequency 120 Poles ,

Poles =

Frequency 120 Speed

uestion -1
Number of poles : 4 GEN output

Hz
1500min-1

Frequency (Hz) =

Speed(min-1) Poles 120

= 15004120 = 50 (Hz)

uestion -2

ENG output

kW ENG GEN

GEN output

100kW

GEN efficiency 90% GEN output (kW) ENG output (kW) = GEN efficiency (=GEN input) = 1000.9 = 111 (kW)

Volt Amperes kVA -In single-phase systems kVA = 1000 3 volt Amperes 1000 3 = 1.732

In three-phase systems

kVA =

Power Factor

-The ratio of active power (watts or kilowatts) used in a circuit to the apparent power delivered to the circuit. ACTIVE POWER (kW) POWER FACTOR (P.F) = APPARENT POWER (kVA)

kW = kVA P.F

PRINCIPLE OF GENERATOR

THE END
Thank you

Vous aimerez peut-être aussi