Main Index
Corporate Europe Asia Pacific
MSC.Software Corporation MSC.Software GmbH MSC.Software Japan Ltd.
2 MacArthur Place Am Moosfeld 13 Shinjuku First West 8F
Santa Ana, CA 92707 USA 81829 Munich, Germany 23-7 Nishi Shinjuku
Telephone: (800) 345-2078 Telephone: (49) (89) 43 19 87 0 1-Chome, Shinjuku-Ku
Fax: (714) 784-4056 Fax: (49) (89) 43 61 71 6 Tokyo 160-0023, JAPAN
Telephone: (81) (3)-6911-1200
Fax: (81) (3)-6911-1201
Worldwide Web
www.mscsoftware.com
Disclaimer
This documentation, as well as the software described in it, is furnished under license and may be used only in accordance with
the terms of such license.
MSC.Software Corporation reserves the right to make changes in specifications and other information contained in this document
without prior notice.
The concepts, methods, and examples presented in this text are for illustrative and educational purposes only, and are not
intended to be exhaustive or to apply to any particular engineering problem or design. MSC.Software Corporation assumes no
liability or responsibility to any person or company for direct or indirect damages resulting from the use of any information
contained herein.
User Documentation: Copyright ©2008 MSC.Software Corporation. Printed in U.S.A. All Rights Reserved.
This notice shall be marked on any reproduction of this documentation, in whole or in part. Any reproduction or distribution of this
document, in whole or in part, without the prior written consent of MSC.Software Corporation is prohibited.
The software described herein may contain certain third-party software that is protected by copyright and licensed from
MSC.Software suppliers. Contains IBM XL Fortran for AIX V8.1, Runtime Modules, (c) Copyright IBM Corporation 1990-2002,
All Rights Reserved.
MSC, MSC/, MSC Nastran, MD Nastran, MSC Fatigue, Marc, Patran, Dytran, and Laminate Modeler are trademarks or registered
trademarks of MSC.Software Corporation in the United States and/or other countries.
NASTRAN is a registered trademark of NASA. PAM-CRASH is a trademark or registered trademark of ESI Group. SAMCEF is
a trademark or registered trademark of Samtech SA. LS-DYNA is a trademark or registered trademark of Livermore Software
Technology Corporation. ANSYS is a registered trademark of SAS IP, Inc., a wholly owned subsidiary of ANSYS Inc. ACIS is a
registered trademark of Spatial Technology, Inc. ABAQUS, and CATIA are registered trademark of Dassault Systemes, SA.
EUCLID is a registered trademark of Matra Datavision Corporation. FLEXlm is a registered trademark of Macrovision
Corporation. HPGL is a trademark of Hewlett Packard. PostScript is a registered trademark of Adobe Systems, Inc. PTC, CADDS
and Pro/ENGINEER are trademarks or registered trademarks of Parametric Technology Corporation or its subsidiaries in the
United States and/or other countries. Unigraphics, Parasolid and I-DEAS are registered trademarks of UGS Corp. a Siemens
Group Company. All other brand names, product names or trademarks belong to their respective owners.
P3*2008R1*Z*THM*Z* DC-USR
Main Index
Contents
MSC Patran Thermal User’s Guide Volume 1: Thermal/
Hydraulic Analysis
1 Introduction
Purpose 2
2 Getting Started
Objectives 14
Model Description 15
Exercise Procedure 15
Temperature Boundary Conditions 25
Nodal Heat Source Boundary Condition 29
Convective Heat Transfer Boundary Condition 30
3 Building A Model
Introduction to Building a Model 38
Geometry Modeling 41
Fields Form 42
Fields Create 42
Material Library 48
Element Properties 53
Element Properties Form 54
Properties Show Material Orientations 57
Input Properties 58
Input Properties Form 58
Main Index
ii MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
4 Module Operation
Preference Files 128
5 Running an Analysis
Review of the Analysis Application 140
Delete 163
6 Reading Results
Overview of Results Import 198
Main Index
CONTENTS iii
7 Thermal/Hydraulic Theory
Network Methods 204
The Thermal Network 204
Conduction Networks 205
Convection Networks 208
Gray Body Radiation Networks 210
Wavelength Dependent Radiation Networks 211
Advection Networks 211
Heat and Temperature Source Networks 213
Flow Networks 213
Main Index
iv MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
9 Convection Library
Convection Configurations 342
Parameter Definitions 344
Configuration 1 347
Configuration 2 350
Configuration 3 353
Configuration 4 356
Configuration 5 358
Configuration 6 360
Configuration 7 361
Configuration 8 363
Configuration 9 365
Configuration 10 367
Configuration 11 368
Configuration 12 370
Configuration 13 372
Configuration 14 375
Configuration 15 378
Configuration 16 380
Configuration 17 382
Configuration 18 386
Configuration 19 389
Configuration 20 392
Main Index
CONTENTS v
Configuration 21 395
Configuration 22 398
Configuration 23 402
Configuration 24 405
Configuration 25 407
Configuration 26 409
Configuration 27 411
Configuration 28 413
Configuration 29 414
Configuration 30 415
Configuration 31 416
Configuration 32 416
Configuration 33 419
Configuration 34 420
Configuration 35 421
Configuration 36 422
Configuration 37 423
Configuration 38 427
Configuration 39 428
Configuration 40 429
Configuration 41 431
Configuration 42 433
Configuration 43 435
Configurations 44-999 437
Configurations 1000+ 437
10 Microfunction Library
Microfunction Library 440
Microfunction Format 441
Microfunction Options 442
Option 1 - Constant 442
Option 2 - Power Series 442
Option 3 - Sine Wave 443
Option 4 - Square Wave 444
Option 5 - Step Function 445
Option 6 - Ramp Function 446
Option 7 - Exponential Function 447
Option 8 - Linear Interpolation of a Data Table 448
Option 9 - Hermite Polynomial Interpolation of a Data Table 449
Option 10 - Repeating Waveform - Linearly Interpolated Data Table 450
Option 11 - Repeating Waveform - Hermite Interpolated Data Table 451
Option 12 - Natural Logarithm Option 452
Main Index
vi MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
11 User-Supplied Routines
User-Supplied Subroutines 466
Main Index
CONTENTS vii
A References
References 600
Main Index
viii MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
D Example Problems
Overview 766
Main Index
CONTENTS ix
Main Index
x MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Main Index
Chapter 1: Introduction
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
1 Introduction
J
Purpose 2
J
Features and Capabilities 3
J
Integration with Patran 12
Main Index
2 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Purpose
Purpose
Patran Thermal is a automated thermal modeling and analysis system for the solution of steady-state and
transient problems. It is a fully-integrated analysis preference in Patran, providing an easy to use forms
setup environment that guides the user to perform a successful thermal analysis. Patran Thermal has
built-in viewfactor and flow network programs that use the same Patran finite element model, eliminating
duplicate modeling. Patran Thermal features a large temperature-dependent materials library, extensive
built-in functions and a convection correlations library. User subroutines can be added in the initial
problem setup to meet the requirements of specialized applications.
Main Index
Chapter 1: Introduction 3
Features and Capabilities
Main Index
4 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Features and Capabilities
Main Index
Chapter 1: Introduction 5
Features and Capabilities
Main Index
6 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Features and Capabilities
• Variable mass flow energy balance Linear bar faces for 2D x/y elements
Main Index
Chapter 1: Introduction 7
Features and Capabilities
• SINDA 85 format
• SINDA/G (BCD) format
• Ready-to-run SINDA deck
• Includes radiation resistors
generated by viewfactor program
• Material properties automatically
loaded into Array Data
• Complete Constants Data and
Execution blocks
Main Index
8 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Features and Capabilities
• Solution algorithms:
• Unconditionally stable implicit predictor/
corrector method (Hughes)
• Explicit method (Euler)
• Strongly Nonlinear Point Successive Over
Relaxation equation solver for implicit
transient or steady-state calculations
• Direct solver and combined direct/
iterative solutions
• User-controlled parameters for fast
solutions of nearly linear problems
• Solution techniques:
• Optional automatic selection of implicit or
explicit solution on a node-by-node and
time step-by-time step basis
• Automatically calculates and updates
convergence acceleration parameters for
iterative solutions
Main Index
Chapter 1: Introduction 9
Features and Capabilities
• Patran Specific:
• Intuitive forms driven interface
Main Index
10 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Features and Capabilities
Main Index
Chapter 1: Introduction 11
Features and Capabilities
Main Index
12 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Integration with Patran
If Full Run is set, the Apply selection in the Analysis form will create the appropriate interface files and
execute the solver. The interface files created include:
• A neutral file
• The analysis control files qin.dat and vf.ctl
• The script input for executing the model patq.inp
• The material properties file mat.dat
• The field definition file micro.dat
Note: Append files may be included in the same directory as the Patran database which will be
automatically added to each job submitted from the Analysis form. The supported append
files are: mat.dat.apnd, micro.dat.apnd, template.dat.apnd, and convec.dat.apnd.
Patran Thermal is designed to support the functionality in P/THERMAL 2.6, including the View factor
code, the new coupled thermal/hydraulic networks and creation of a SINDA input deck. Overall, users
will find Patran Thermal a much easier to use product without sacrificing the powerful capabilities of
P/THERMAL.
Main Index
Chapter 2: Getting Started
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
2 Getting Started
J Objectives 14
J Model Description 15
Main Index
14 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Objectives
Objectives
This getting started tutorial goes through the basic steps in creating a Patran Thermal model, submitting
the analysis, and visualizing the results.
• Build a two-dimensional thermal model in Patran (Geometry and Finite Elements).
• Apply temperature, heat flux, nodal heat source, and convective boundary conditions.
• Apply elements properties.
• Create a run-ready analysis deck and spawn a thermal batch job.
Important: For more information about module operation, with step-by-step instructions for various
types of thermal applications, see Reference Notes, 129.
Main Index
Chapter 2: Getting Started 15
Model Description
Model Description
In this exercise you will determine the steady-state temperature distribution in a 1m by 1m Aluminum
slab. The slab will be modeled in two dimensions. The loads and boundary conditions you will apply to
the model are shown in the figure below
.
Exercise Procedure
Accessing Patran
Step 1: In your xterm window, type patran to start Patran.
You should see various status messages being printed in the xterm window. After a short time,
the following Patran main form will appear.
Main Index
16 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Initially, all selections within the main form are ghosted except the File selection. Typically
when an option does not pertain to the task you are performing, Patran ghosts that selection to
make it easier for you to choose the viable options. For example, move the cursor to the File
selection in the main form and click the left mouse button. In the pull-down menu that appears
(also shown below), the operations that do not pertain to manipulating databases are ghosted,
since the first thing you must do when starting Patran is access a database.
Main Index
Chapter 2: Getting Started 17
Model Description
Let’s stop for a moment to discuss the icons located in the main form. Notice the Patran
Heartbeat in the upper right-hand corner of the main form.
Main Index
18 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
If the Heartbeat is red, Patran is busy with an operation and cannot be interrupted. Typing or
mouse selections at this time will be ignored.
There are two more buttons in the upper right-hand corner of the main form. One is the Refresh
button (the paint brush) and the other is the Undo button (the eraser).
Main Index
Chapter 2: Getting Started 19
Model Description
The Refresh button repaints the model. After you delete something from the viewport
or pull menus over the viewport, the model might need repainting. If it does, press the
Refresh icon.
The Undo button can be used to undo most commands. Only the previous operation
can be undone by the Undo button.
The Interrupt button is used to stop Patran from completing the process in which it is
working. You can only use it when the heartbeat is blue. It will ask you to confirm the
interruption.
Step 2: After the database is opened, a New Model Preferences form will appear. Select the Default
Tolerance and change the Analysis Code to Patran Thermal. The completed form is shown
below for your reference.
Main Index
20 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
The form’s default settings will create a 1 x 1 patch at the default global coordinate origin. Click
on Apply to create the patch. Your Geometry form and patch model should now look like the
ones shown below.
To turn on labels click on the Show Label icon. Use the Label Control icon to select specific
labels.
The number of geometric display lines can be changed on the Display -> Geometry and
specifying the number of lines desired.
Step 4: To create the finite element model, click on the Elements toggle in the main form. Set the
Action, Object, and Type pull-down options to Create, Mesh, and Surface. To mesh the patch
with a 5x5 mesh density (i.e., 4x4 elements), change the Global Edge Length to 0.25.
Select the Quad4 Element Topology. Since the patch you have created has four sides, choose
IsoMesh Mesher option.
When a surface has more than 4 edges, you must use the Paver Mesher option or you can
decompose the n-sided surface into subsurfaces containing no more than 4 edges and use the
IsoMesher.
Main Index
Chapter 2: Getting Started 21
Model Description
Click in the Surface List databox at the bottom of the Finite Elements form. Select Surface 1
and click on Apply to create the finite element mesh. Your completed Finite Elements form and
model should look like the ones shown below. Node 999 is created later.
Step 5: You will now define the model’s Element Properties. Click on the Properties toggle in the main
form.
When the Element Properties form appears set the Action, Dimension, and Type option menus,
to Create, 2D, and Thermal 2D. Enter the Property Set Name, Prop1.
Next, click on the Input Properties button. When the Input Properties form appears, you will
see the Material Name, Material Orientation-X, Material Orientation-Y, and Material
Orientation-Z databoxes. For this exercise, you will use the Patran Thermal material database.
Aluminum is the first material that occurs in the database (Material ID, MID=1). To use the
Aluminum Material, type 1 in the Material Name databox. The material is isotropic; therefore,
no directional data (material orientation angles) will be input to the form. The Element
Properties and Input Properties forms are shown below for your reference.
Main Index
22 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Main Index
Chapter 2: Getting Started 23
Model Description
Click on the Apply button to create and assign the Element Properties to the model.
Step 6: In this step you will create a finite element node, next to, but not on your model. The node will
represent the model’s surrounding environment. In a later step, you will assign the
environmental (ambient) temperature to the node. This temperature is needed for the convective
film coefficient definition. Click on the Elements toggle in the main form. Set the Action,
Object, and Type option menus to Create, Node, and Edit. Change the Node ID List to 999.
This number is the ID of the next node to be created.
Main Index
24 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Next, set the Associate with Geometry button off and click in the Node Location List databox.
In the select menu, highlight the right most icon, which allows you to select an arbitrary screen
position. Click in the graphics window at a position, next to, but not on the model to specify the
position of Node 999. Click on the Apply button to create the node. The completed Finite
Element form and model are shown below for your reference.
Main Index
Chapter 2: Getting Started 25
Model Description
Step 7: You will now assign the thermal boundary conditions for the model.
Main Index
26 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Click on the OK button to close the form. Next, click on the Select Application Region button. When
the Select Application Region form appears, set the Geometry Filter to Geometry and click in the Select
Geometry Entities databox. In the select menu, highlight the curve icon since you will now apply the
temperature to the left vertical edge of the patch. Click on the left vertical edge of the patch and Surface
1.1 will appear in the Select Geometry Entities box. Add this selection to the Application Region box.
The completed form is shown below.
Main Index
Chapter 2: Getting Started 27
Model Description
Click on the OK button to close the form. Click on the Apply button to create the temperature boundary
condition. Your model should now look similar to the one below.
Main Index
28 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
To apply the ambient temperature to Node 999, create a new temperature set named Temp2 with the
Option menu again set to Fixed. Enter a temperature of 300 in the Input Data form and click on the OK
button. In the Select Application Region, choose the FEM Geometry Filter. Click in the Select Nodes
databox and select Node 999 in the viewport. Add this node to the Application Region and click on the
OK button. The completed forms are shown below for your reference.
Main Index
Chapter 2: Getting Started 29
Model Description
Finally, click on the Apply button in the Loads/Boundary Conditions form to create the second
temperature boundary condition.
Main Index
30 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Main Index
Chapter 2: Getting Started 31
Model Description
Step 8: You are now finished defining your analysis model. In this step, you will submit the job for
analysis.
Click on the Analysis toggle on the main form. In the Analysis form that appears. The job name
is assigned the database name and the job description references the session file used to create
the model at the time of construction. Go ahead and change these to something more meaningful
if desired. Click on the Translation Parameters button. The following Patran Thermal
Translation Parameters form will appear.
Main Index
32 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
The default model dimensionality is 2D and the file to extract undefined materials is
mpidmks.bin. To use these default settings, click on the OK button at the bottom of the form.
You will also use the default setting found in the Solution Type, Solution Parameters, Output
Requests, and Submit Options forms. If you would like to inspect these forms, feel free to do so
but do not change the default settings.
To submit the analysis run, click on the Apply button at the bottom of the Analysis form. Patran
Thermal will create the jobname directory (exercise_1 if you did not change it) and spawn the
Patran Thermal job.
Patran Thermal will create a subdirectory with the job name exercise_1 containing the data
files, message files and the results file for this analysis. If you would like to check the status,
open a new window and look at the contents of the exercise_1/patq.msg.01 file. If
there is a stat.bin file present, you can check the progress of the solution convergence by
typing in this shell the command:
% qstat
Main Index
Chapter 2: Getting Started 33
Model Description
By selecting Thermal Tools as the action on the analysis menu, you can obtain an interactive
XY plot of the convergence status as the job is being executed.
Step 9: After the job is complete (this job takes less than a minute), change the Action pull-down option
menu on the top of the Analysis form to Read Results. Next, click on the Select Results file
button. When the Select File form appears, select the subdirectory for the job just submitted by
double clicking the appropriate path:
... ./exercise_1/*.nrf*
Update the Available Files list by clicking on the Filter button. Highlight the file, nr0.nrf.01, in
the Available Files list. Your edited Select File form should now look like the one shown below.
Main Index
34 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Main Index
Chapter 2: Getting Started 35
Model Description
Main Index
36 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Model Description
Main Index
Chapter 3: Building A Model
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
3 Building A Model
Main Index
38 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Introduction to Building a Model
The Analysis Code Selection may be changed at any time during model creation. As much data as
possible will be converted if the analysis code is changed, after the modeling process has already begun.
The setting of this option defines what will be presented to the user, in several areas, during the
subsequent modeling steps. For more details, see Analysis Form (Ch. 5) in the Patran Thermal User’s
Guide Volume 1: Thermal/Hydraulic Analysis.
Main Index
Chapter 3: Building A Model 39
Introduction to Building a Model
Material Definition
In this release of Patran Thermal, materials must be specified as a number (e.g., 18 or m:18) or by a name
(e.g., steel). The materials set is created when the number or name is entered in the Element Properties
form. The material number refers to a material ID in the template.dat file. If a definition is not found
in the local template corresponding to the material number and the material number is in the range 1 to
971, P/THERMAL will use the MID Template delivered with the solver and load the temperature
dependent material properties. The material IDs associated with the database delivered with the module
can be found in Mid Templates Supplied in Templatebin and Templatetxt (App. B) in the Patran Thermal
User’s Guide Volume 1: Thermal/Hydraulic Analysis.
Main Index
40 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Introduction to Building a Model
If a material is specified in the element properties form by a name, the names are added to the Material
Sets and will be numbered at translation time sequentially in the order they were created. For example,
if the materials set created by defining materials under Element Properties are given the names
Zirconium, Steel and Carbon-Felt, they will be assigned MID numbers 1, 2 and 3, respectively. These
MIDs must be further defined in the MID Template since these materials do not correspond to the MID
templates supplied with the module.
Main Index
Chapter 3: Building A Model 41
Geometry Modeling
Geometry Modeling
Building the geometry for a thermal model with Patran is nearly identical to the procedure that is used to
build a structural model, and in many cases the geometry can be shared between these two applications.
As in other Patran applications, geometry can be directly accessed through Working with Files (Ch. 4) in
the Patran Reference Manual (SGM), or created with the Create Actions (Ch. 4) in the Geometry
Modeling - Reference Manual Part 2. Besides the part being modeled, occasionally additional geometry
is required in the thermal model to represent the advection and hydraulics network, or for use in
specifying symmetry planes for the Viewfactor code.
Main Index
42 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Fields Form
Fields Form
The Fields form will appear when the Fields toggle, located on the Patran application switch, is chosen.
The selections made on the Materials menu will determine which material form appears.
The following pages give an introduction to the Fields form, and details of all the fields definitions
supported by the Patran Thermal Application Preference.
The functions on the Fields menu are listed and described below in the order in which they appear on the
menu.
Tabular Input
General
FEM
• Material Property General
• Non Spatial General
Note: Non -Spatial/Tabular Input Fields are not supported by Patran Thermal.
Fields Create
The Fields form is used to create Spatial, Non Spatial and Material Property fields.
Main Index
Chapter 3: Building A Model 43
Fields Form
Caution: The field is not created until Apply is selected. Wait for the new field name to appear in the
Existing Fields databox after selecting Apply.
Main Index
44 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Fields Form
Caution: This button works only for terms which are functions (terms preceded by an integer prefix).
Attempting to modify terms which are functions in the text box via the keyboard will result
in an error.
Note: Although Material Property/Tabular Input is supported by Patran Thermal for defining
Materials, the General Method provides more flexibility such as temperature units
conversions and is the recommended approach.
Main Index
Chapter 3: Building A Model 45
Fields Form
Main Index
46 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Fields Form
Caution: This button works only for terms which are functions (terms preceded by an integer prefix).
Attempting to modify terms which are functions in the text box via the keyboard will result
in an error.
Note: Patran Thermal does not support Non-Spatial/Tabular Fields. Use only Non-
Spatial/General Fields.
Main Index
Chapter 3: Building A Model 47
Fields Form
Main Index
48 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Library
Material Library
Patran Thermal provides three ways to define material properties:
• Define the material properties under Materials/Manual Input/Thermal Properties constituative
model. The properties data is entered as values which can be a constant, or a time or temperature
dependent field.
• Reference Patran Thermal’s 971-member library of materials delivered with Patran Thermal.
This Materials Library (p. 602) contains temperature dependent properties in units of SI, Inch-
Lbm-Seconds, Foot-Lbm-Hours, and Centimeter-Gram-Seconds. To access the materials library,
use an MID number between 1 and 971 for the Material Name, and do not define any Input
Properties. The materials database in the desired units is selected in the Analysis/ Translation
Parameters Form. The Patran Thermal materials library can also be accessed with the Material
Selector method if Patran Material Selector is available.
Important: Do not mix material names (“Stainless”) and material numbers (“1”) in the model if
referencing the Patran Thermal Material Library. A material name such as Cres.347 will
be interpreted as MID 347.
This form appears when Materials is selected on the main menu. The Materials form is used to provide
options to create the various Patran Thermal materials.
Main Index
Chapter 3: Building A Model 49
Material Library
Important:Do not mix material names (“Stainless”) and material numbers (“1”) in the model. A
Material Name such as Cres.347 will be interpreted as MID 347.
Main Index
50 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Library
3D Orthotropic
The properties list under Property Name can be input as a number or can be selected from the Material
Property fields created under the Fields menu. These thermal properties are translated into a mat.dat
file (residing in the <jobname> subdirectory).
All Material Property defined in the Fields menu will be translated to the mat.dat file. Also, any
material properties constant data entered in the Materials Input Data form is written to the mat.dat file.
If a number has been specified for the material name, it will be used by Patran Thermal as the MID and
the material property will have a suffix added to it for the MPID. If a name is used to define the material,
the next available MID (plus an offset of 1000 to prevent conflicts with the Patran Thermal materials
database) will be used. An MID template is automatically created in the template.dat file located in
the <jobname> subdirectory for all the materials defined from within Patran.
Caution: A material name such as cres.345 will be interpreted as MID 345. Do not mix an MID
number (e.g., 1) and a name (e.g., stainless) in the same database.
Main Index
Chapter 3: Building A Model 51
Material Library
Important:When the analysis is submitted, Patran Thermal will automatically create the necessary
entries in the <jobname>/template.dat and mat.dat files.
3D Orthotropic
The following form is used to input the Material Property IDs for the thermal properties.
Main Index
52 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Library
Important:When the analysis is submitted, Patran Thermal will automatically create the necessary
MID template entry in the <jobname>/template.dat file.
Main Index
53
Element Properties
Element Properties
By choosing the Element Properties toggle, located on the application switch for Patran, an Element
Properties form will appear. When creating element properties, several option menus are available. The
selections made in these option menus will determine which element property form is presented, and
ultimately, which Patran Thermal element will be created.
The standard Patran Finite Element methods are used for generating elements in the thermal model. The
elements supported by Patran Thermal are detailed in the following subsections. Only linear elements
are currently supported by Patran Thermal. These include linear bars, triangles, quadrilaterals,
tetrahedrons, wedges, and hexahedrons.
Conductive elements must have a material ID (MID) or material name assigned. This Patran MID
number corresponds to a material property template.
Material orientation angle information may be optionally assigned for 2-D and 3-D elements. The
material angles are referred to as Axis-1ROT, Axis-2ROT, and Axis-3ROT. These angles may be specified
relative to the global system, an alternate coordinate system, or the elemental coordinate system. The
material orientation system and angular values are used to transform the orientation of the element
material's principal axes system relative to the global X, Y, and Z system. For a rectangular coordinate
system, the material's principal axes system is rotated within the specified coordinate frame first about
the X, then about the new Y axis after XROT, and finally about the new Z axes by angular values of
XROT, YROT, and ZROT degrees. These angles may reference a spatial field. Similarly, in the case of a
cylindrical coordinate system the rotations are about R, T, and Z. In referencing a cylindrical coordinate
system, the default for an orthotropic material is Kxx along axis-1 (Radial), Kyy along axis-2 (Theta) and
Kzz along axis-3 (Z).
Note that 2-D Cartesian elements rotate only about the Z-axis, while 2-D axisymmetric elements rotate
about an axis given as the cross product of the R and Z axes. Orthotropic material orientation can be
visualized under the Element Properties Show action. Examples of element properties definitions for
orthotropic materials orientations are included under the 2-D shell and 3-D solid element properties
definition forms.
The Element Property forms are also used to supply element thickness information for 2-D shell elements
(bars) and 3-D shell elements (triangles and quadrilaterals), as well as providing Geometric Property
(GP) data for convective quadrilateral elements. More specific information is given in the following
subsections.
The following pages give an introduction to the Element Properties form, followed by the details of all
the element property definitions supported by Patran Thermal.
Main Index
54 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Element Properties
Main Index
55
Element Properties
The following table shows the allowable selections for all option menus for Patran Thermal.
Main Index
56 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Element Properties
Main Index
57
Element Properties
Note: The displayed labels can be set under the main menu Display- Load/BC/Elem Prop
Main Index
58 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Input Properties
Note: This 0D element replaces the functionality of type “F” and “I” nodes in PATRAN 2.5.
Bar Elements
Patran Thermal uses bar elements for the following purposes:
Main Index
59
Input Properties
Figure 4-1 2-D Cartesian (X-Y) Element Demonstrating Unit Depth in the Z Direction
The two thickness values allow for a linear variation of thickness along the bar axis. The average
thickness is used (along with the assumption of unit depth along the Z-axis) to compute an effective
cross-sectional area for the thermal resistors, and the distance between the bar nodes is used to compute
Main Index
60 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
an effective length. Capacitance volumes are computed based on the linear variation of thickness
assumption coupled with the half-length of the bar.
Conduction bar elements, without capacitance for 2-D Cartesian models, are similar, except that no
capacitors are generated.
Conductive bar elements will be interpreted as 2-D Cartesian when the Model Dimensionality has been
specified as 2-D Plane Geometry under Analysis/ Translation Parameters.
Conduction Bar
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
3D Conduction Bar
Conductor
Main Index
61
Input Properties
Advection Bar
Advection is the transport of heat energy by a mass flow stream. Advection bars generate advective
resistors and no capacitors. These data items consist of the following:
• CPMPID for specific heat material property ID (Cp)
If no MPID number is given for the variable mass flow rate, the constant MDOTC will be taken as the
constant mass flow rate for the advective bar and for the resulting QTRAN advective resistors. If the
optional MPID number for a variable mass flow rate is also given, then the MDOTC value is used as a
scale factor and the effective mass flow rate is computed from the product of the MPID's value and
MDOTC.
Mass flow is considered positive in the direction of element node 1 to element node 2, and negative from
element node 2 to element node 1.
Main Index
62 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Note: Advection moves energy from one node to another and quasi steady state is implicit in this
formulation. If transient analysis is to be performed, conduction bars need to be assigned
parallel to the advection bars so the internal energy in each fluid node is properly modelled.
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
This bar element is used to define the flow of a fluid when the mass flow rate is known.
Note: The MPID is an integer number referring to a user-defined MPID in the mat.dat file or to a
Material Property/General Fields, 43 with this MPID number in the Input Data Form.
Main Index
63
Input Properties
Main Index
64 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Input required for the various options available for Flow Network Pipe.
Option Description
Property Name Constant Property with Moody Curve Variable Property
[TID] Supply a non-zero dummy TID value. Pointer to FLUID Template
ID in template.dat.
IOPT Enter a 1. Enter a 2. Enter a 3.
[Pipe diameter] Hydraulic diameter of the flow passage defined as 4*CSArea/wetted
perimeter. (For a circular cross section, hydraulic diameter=physical
diameter). If diameter is not specified, it will be calculated using the cross-
sectional area and wetted perimeter specified below.
[Pipe c.s. area] Cross-section area of the flow passage. If not specified it will be calculated
assuming a circular cross section and specified diameter.
[Pipe perimeter] Wetted perimeter of the flow passage. If it is not specified, it is calculated
assuming a circular cross section.
Main Index
65
Input Properties
Option Description
Property Name Constant Property with Moody Curve Variable Property
[Pipe length] The length of the bar element. If it is not specified, it will be calculated as the
straight line distance between the end nodes of the bar element.
[Pipe roughness] Surface roughness of the tube or the flow passage.
[Head loss coeff] Head loss coefficient to account for minor A scale factor to the
losses in the flow network, e.g., losses in bends, MPID_LOSS_COEF
tees, valves, sudden expansion/contractions, material property in the
etc. FLUID Template.
[Fluid density] Specific weight (F/L3), dynamic viscosity Fluid density
(M/LT) and specific heat of the fluid flowing (MPID_RHO), viscosity
[Fluid viscosity] through the network. Must be consistent with (MPID_MU) and specific
the units that are used to solve the thermal heat (MPID_CP) are
[Specific Heat] defined in the FLUID
problem. If applicable to the system of units,
Patran Thermal will convert specific weight to template.*
mass-density based on the ICCALC flag.
[Friction factor]* Friction factor used to [not present for this Scale factor to the MPID_F
calculate the head loss option]. Patran material property defined in
due to flow. Thermal will compute the FLUID template.
the friction factor from
Moody’s chart. Note: A zero
MPID_F
activates the
Moody
equation.
[Coeff thermal Coefficient of thermal expansion used in Thermal expansion
expansion] calculation of buoyancy head. coefficient is defined with
an MPID_BETA material
note: Gravitational constant and direction is property in FLUID
specified under Hydraulic Run Control template. *
Parameters.
* a dummy value must be entered for these parameters.
Main Index
66 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Main Index
67
Input Properties
Option Description
Main Index
68 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Option Description
Main Index
69
Input Properties
MPID_MU Material property ID which references the dynamic viscosity of the fluid flowing
through the network (units = M/LT).
MPID_CP Material property ID which references the specific heat of the fluid flowing through
the network.
MPID_HEAD Turbine head as function of time or flow rate.
Note: Turbine head can be a function of time or flow rate. For independent
variable of flow rate, build the MPID as if it were “temperature”
dependent in the same ITSCAL units as the solution temperature units,
ICCALC.
Main Index
70 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Option Description
Property Name Constant Property Variable Property
[TID] Supply a non-zero dummy Pointer to FLUID Template ID in
TID value. template.dat.
IOPT Enter a 4.+ Enter a 5.
Main Index
71
Input Properties
Option Description
Property Name Constant Property Variable Property
[Fluid density] Specific weight (F/L3), Fluid density (MPID_RHO), viscosity
dynamic viscosity (M/LT) and (MPID_MU) and specific heat (MPID_CP)
[Fluid viscosity] specific heat of the fluid are defined in the FLUID template. A
flowing through the network. dummy value must be entered on the form.
[Specific Heat]
Must be consistent with the
units that are used to solve the
thermal problem. If applicable
to the system of units, Patran
Thermal will convert specific
weight to mass-density based
on the ICCALC flag.
[Turbine head] Constant pump head, cannot Pump head is defined with an MPID_HEAD
go negative. material property in the FLUID template.
The independent variable for head can be
time or flowrate. A dummy value must be
entered on this form.
Main Index
72 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Note: Pump head can be a function of time or flow rate. For independent
variable of flow rate, build the MPID as if it were “temperature”
dependent in the same ITSCAL units as the solution temperature
units, ICCALC.
This element defines a check valve in the flow network. A flow reversal would close the valve.
Main Index
73
Input Properties
This is a list of data input available for creating the flow network bar element, which were not shown on
the previous page. Use the scroll bars to view these properties.
Option 9, CHECK VALVE, constant physical and material properties for fluid flow in a tube. One way
flow. If the fluid flow is not from NODE1 to NODE2, the diameter becomes zero (0.0). Friction factor is
evaluated by Patran Thermal using Moody’s equation.
Main Index
74 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
TID A dummy ID, not used by Patran Thermal flow network. Supply a nonzero
dummy TID. No template record required.
IOPT The option chosen for the flow bar element. IOPT = 9.
DIAM A hydraulic diameter of the flow passage defined as 4 * CSArea / wetted
perimeter. (For a circular cross section hydraulic diameter = physical diameter.)
If diameter is not specified, it will be calculated using the cross sectional area
and wetted perimeter.
CSAA Cross sectional area of the flow passage. If it is not specified, it will be calculated
assuming a circular cross sectional and specified diameter.
PERIM Wetted perimeter of the flow passage. If it is not specified, it is calculated
assuming a circular cross section.
LENGTH The length of the bar element. If it is not specified, it will be calculated as the
straight line distance between the end nodes of the bar element.
ROUGHNESS Surface roughness of the tube or the flow passage.
LOSS_COEFF Head loss coefficient to account for minor losses in the flow network, e.g. losses
in bends, tees, values, sudden expansion/contraction, etc.
DENSITY The specific weight of the fluid flowing through the flow network (units of
F/L3). Specific weight must be consistent with the units that are used to solve
the thermal problem. If applicable to the system of units, Patran Thermal will
convert specific weight to mass-density based on the ICCALC flag.
VISCOSITY Dynamic viscosity of the fluid flowing through the network (units = M/LT).
SPECIFIC_HEAT Specific heat of the fluid flowing through the network.
HBETA Is the coefficient of THERMAL expansion used in calculation of buoyancy head
(g * HBETA * DT).
Option 10, CHECK VALVE, constant physical and variable material properties for fluid flow in a tube.
One way flow. If the fluid flow is not from NODE1 to NODE2, the diameter becomes zero ( 0.0 ).
Material properties defined with MPID's. Requires template definition.
Main Index
75
Input Properties
TID User template ID. A nonzero value which couples the PFEG record to the
information referenced in the template file.
IOPT The option chosen for the flow bar element. IOPT = 10.
DIAM A hydraulic diameter of the flow passage defined as 4 * CSArea / wetted
perimeter. (For a circular cross section hydraulic diameter = physical diameter.)
If diameter is not specified, it will be calculated using the cross sectional area
and wetted perimeter.
CSAA Cross sectional area of the flow passage. If it is not specified, it will be calculated
assuming a circular cross sectional and specified diameter.
PERIM Wetted perimeter of the flow passage. If it is not specified, it is calculated
assuming a circular cross section.
LENGTH The length of the bar element. If it is not specified, it will be calculated as the
straight line distance between the end nodes of the bar element.
ROUGHNESS Surface roughness of the tube or the flow passage.
LOSS_COEFF Head loss coefficient to account for minor losses in the flow network, e.g., losses
in bends, tees, values, sudden expansion/contraction, etc. This loss coefficient
becomes a scale factor and is used as a multiplier to the value return from the
MPID_LOSS_COEFF material property.
Template Definition:
FLUID TID MPID's IOPT
MPID_RHO MPID_MU MPID_CP
MPID_LOSS_COEFF MPID_BETA MPID_F
Main Index
76 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
This is a head loss element used to define the losses in a flow network (e.g., losses in orifices, valves,
bend, tees, etc.).
Main Index
77
Input Properties
Option 8, LOSS ELEMENT or CONTROL VALVE, variable parameters for fluid flow in a tube.
Parameters input in the Element Property form will be used as scale factors applied to the material
property evaluations obtained for the MPIDs defined. Requires template definition.
Main Index
78 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
TID User template ID. A nonzero value which couples the Element Property record
to the information referenced in the template file.
IOPT The option chosen for the flow bar element. IOPT = 8.
DIAM A hydraulic diameter of the flow passage defined as 4 * CSArea / wetted
perimeter. (For a circular cross section hydraulic diameter = physical diameter.)
If diameter is not specified, it will be calculated using the cross sectional area
and wetted perimeter.
LENGTH The length of the bar element. If it is not specified, it will be calculated as the
straight line distance between the end nodes of the bar element.
ROUGHNESS Surface roughness of the tube or the flow passage.
LOSS_COEFF Head loss coefficient to account for minor losses in the flow network, e.g. losses
in bends, tees, values, sudden expansion/contraction, etc. This loss coefficient
becomes a scale factor and is used as a multiplier to the value returned from the
MPID_LOSS_COEFF material property.
Main Index
79
Input Properties
MPID_LOSS_COEF Material property ID which references the loss coefficient. Could be used to
model the change in loss coefficient of a global valve which has different
openings as a function of time.
MPID_BETA Material property ID which references the coefficient of thermal expansion
used in calculating the buoyancy head (g * HBETA * DT).
MPID_F Material property ID which references the friction factor used to calculate the
head loss due to flow in a tube.
Main Index
80 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Option 11, PLENUM, constant physical and material properties. Conditions across a plenum element
are unaffected by flow. The head can be altered by gravity.
TID A dummy ID, not used by Patran Thermal flow network. Supply a nonzero
dummy TID. No template record required.
IOPT The option chosen for the flow bar element. IOPT = 11.
DENSITY The specific weight of the fluid flowing through the flow network (units of
F/L3). Specific weight must be consistent with the units that are used to solve
the thermal problem. *Hydraulic networks prefer a mass density and the units
conversion is performed internally based on the ICCALC flag.
VISCOSITY Dynamic viscosity of the fluid flowing through the network (units = M/LT).
SPECIFIC_HEAT Specific heat of the fluid flowing through the network.
Option 12, PLENUM, variable material properties. Conditions across a plenum element are unaffected
by flow. The head can be altered by gravity. Material properties defined with MPIDs. Requires template
definition.
Main Index
81
Input Properties
TID User template ID. A nonzero value which couples the PFEG record to the
information referenced in the template file.
IOPT The option chosen for the flow bar element. IOPT=12.
Template Definition:
FLUID TID #MPID's IOPT
MPID_RHO MPID_MU MPID_CP
Main Index
82 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
These rotational symmetry bar elements data consist of the number of incremental rotations followed by
the angular increment for each rotation. Since this model is 2-D X-Y, the bar must be parallel to the Z-
axis. In 3-D X-Y-Z, the bar may be arbitrarily oriented. Rotational symmetry bars are illegal for 2-D R-
Z models.
Main Index
83
Input Properties
Note: For R-Z problems, radiation symmetry bars must be parallel to the R Axis.
Main Index
84 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Figure 4-4 Rotational Radiation Symmetry Bar Element (shown here by the circle-and
crosshairs as being parallel to the Z-axis)
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied. This bar element is used to define radiation reflection symmetry.
Input properties are not needed for this bar element.
Main Index
85
Input Properties
Axisymmetric Bar
If the model is an R-Z-axisymmetric model, the bar elements are also treated as 2-D shell elements with
surface areas for convection, radiation, and heat flux boundary conditions (see Figure 4-5). The bars (or
shells) are assumed to be rotated 360° about the Z-axis. Any of Patran's X, Y, or Z-axis can be selected
as the Z-axis (the axis of symmetry) by making the selection under Analysis/Translation Parameters.
As with the 2-D Cartesian bar elements, you must define element properties with a material and two
thickness values (thickness at node 1 and thickness at node 2).
Main Index
86 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Figure 4-5 2-D Axisymmetric (R-Z) Bar Element Demonstrating Rotation About the Z-Axis
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
Note: This element property definition requires setting model dimensionality to axisymmetric
geometry and selecting the radial and centerline axes under the Analysis, Translation
Parameters.
Main Index
87
Input Properties
Thermal Shell
Triangular Elements
Patran Thermal supports 3-node linear triangular elements in either 2-D or 3-D Cartesian (X-Y or X-Y-
Z) geometry or in 2-D axisymmetric (R-Z) geometry. 2-D Cartesian X-Y models must be built in the
Patran X-Y plane. Whether the model dimensionality is 2-D X-Y, 2-D R-Z, or 3-D X-Y-Z is declared
under Analysis/ Translation Parameters. Patran cannot tell the difference between any of these coordinate
systems.
Allowed triangular elements include the following:
• 2-D X-Y conduction triangles
• 2-D R-Z conduction triangles
• 3-D X-Y-Z conduction triangles
• 3-D X-Y-Z radiation symmetry triangles
The 2-D X-Y triangles are assumed to be of unit thickness in the Z direction. The 2-D R-Z triangles are
assumed to be rotated through 360 degrees. The 3-D X-Y-Z conductive triangles (3-D shell elements)
may be oriented at any angle and must have thickness data at each node. 2-D triangular elements do not
use any thickness data.
For 3-D conductive triangular shell elements, all three orientation angles may be supplied, as well as the
three thickness values.
Main Index
88 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Quadrilateral Elements
Patran Thermal supports 4-node quadrilateral elements in the following geometries:
• 2-D Cartesian X-Y geometry
• 2-D axisymmetric R-Z, which to Patran is still X-Y geometry
• 3-D Cartesian X-Y-Z geometry
2-D Cartesian X-Y models must be built in the Patran X-Y plane. 2-D axisymmetric R-Z models may be
built in any plane defined by two Patran axes, e.g., X-Y, Y-Z, X-Z. The dimensionality of the model; i.e.,
2-D X-Y, 2-D R-Z, or 3-D X-Y-Z is defined under Analysis/Translation Parameters.
The 2-D X-Y quadrilaterals are assumed to be of unit thickness, the 2-D R-Z quadrilaterals are assumed
to be rotated through 360 degrees, and the 3-D X-Y-Z quadrilateral shell elements must be given
thickness data.
Both 2-D Cartesian and 3-D shell elements support boundary conditions applied through their edges.
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
This form applies to quad and tri shell elements and require thickness definitions.
Main Index
89
Input Properties
Main Index
90 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Main Index
91
Input Properties
Thermal 2D
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
Main Index
92 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
This form applies to 2D elements. In Patran Thermal, they are treated as unit depth.
Main Index
93
Input Properties
Note: This element property definition requires setting model dimensionality to axisymmetric
geometry and selecting the radial and centerline axes under Analysis, Translation
Parameters.
Main Index
94 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
This form is typically used when modeling a mixed Axisymmetric and 3D model. It applies to
axisymmetric quad and tri elements.
Main Index
95
Input Properties
plane defined by the triangular element. Nodes on these symmetry triangular elements must have OD
elements with Node Type “Information.” These nodes will not participate in the thermal analysis
calculations.
Convective Quad
Convective quadrilateral elements may be used to apply convective boundary conditions to 2-D X-Y or
2-D R-Z models (see Figure 4-7). The advantage of using convective quadrilateral elements as opposed
to the CONV LBC form occurs when a spatial variation of fluid temperature along a fluid-surface
interface occurs, and it is necessary to model the fluid as a series of nodes paralleling the surface.
The shaded elements in Figure 4-7 represent convective quadrilateral elements. These elements may be
used to apply convective boundary conditions to surfaces where the fluid temperature is to be represented
by a series of fluid nodes. The data for convective quadrilateral elements consist of the CONV template
TID number, followed by as many GP values (geometric properties) needed to supply from Patran. The
remaining GP values will be taken, as with the CONV LBC form, from the CONV template.
Main Index
96 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Typically, the fluid nodes are chained together with advective bar elements to model the energy being
carried along on the mass flow stream. The fluid nodes determine which nodes should have convective
resistors generated between them to apply the correct convective boundary conditions for the model.
Convective quadrilaterals must have at least one fluid node associated with each element. Note that if a
convective quadrilateral element has fewer than two surface thermal nodes, there is no surface area
associated with the element and hence no convective resistors will be generated for the element. This
typically occurs at convex corners.
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
This is a convective quad element used to define convective heat transfer between solid and fluid. No
cross resistors are generated for convective quad elements.
Main Index
97
Input Properties
Thermal 3D Solid
Patran Thermal supports 4-node tetrahedral elements for conduction in 3-D Cartesian coordinates. Patran
Thermal also supports 6-node wedge elements for conduction in 3-D Cartesian coordinates.
Hexahedral Elements
Patran Thermal supports 8-node hexahedral elements for conduction in 3-D Cartesian coordinates. FE
Hex elements generate conductive resistors and capacitors using a finite element formulation. Finite Diff
Hex elements generate conductive resistors and capacitors using a finite element formulation on skewed
or orthotropic elements and a finite difference formulation on rectangular isotropic elements. The
advantage of this approach is that models typically run somewhat faster than the pure finite element
models with virtually no loss of accuracy.
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
Main Index
98 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Main Index
99
Input Properties
Note: If a name is entered, the next available MID number will be assigned for use by Patran
Thermal.
Important:Do not mix material names and MID references in the same model.
Main Index
100 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
This form is typically used for mixed axisymmetric and 3D models. The axisymmetric portion is treated
as a 360-degree rotation and the 3D elements are applied a multiplying factor to scale the capacitance and
surface area by the number of times the 3D component repeats.
Main Index
101
Input Properties
Convective Hex/Wedge
Convective Hex
Convective hexahedral elements can be used to generate convective resistors between Convective Fluid
nodes and Thermal Surface nodes (see Figure 4-8). Any one face of a Convective hexahedral element
may be defined by type Fluid nodes, but the remaining 4 nodes must be type Thermal.
Main Index
102 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
These elements can also be used to specify contact coefficients (contact resistance) between surfaces.
Convective Wedge
Patran Thermal supports convective wedge elements. These elements can be used to generate convective
resistors between Fluid nodes and Thermal solid nodes. Valid convective wedge elements are shown in
Figure 4-9.
As can be seen in Figure 4-9, any one triangular face may have all type F nodes, or the degenerate edge
(nodes 1 and 4) may be type F nodes. Any other arrangement is illegal. These elements can also be used
to define contact resistances. These elements must be given Element Properties consisting of a CONV
Template ID pointer and appropriate geometric parameters for the chosen configuration.
Main Index
103
Input Properties
Figure 4-9 Convective Wedge Elements showing usage of Node Type “Fluid” to designate
which face will be considered the Thermal Surface
This form appears when the Input Properties button is selected on the Element Properties form and the
following options have been applied.
These are convective hex/wedge elements used to define convective heat transfer between solid and
fluid. No cross resistors are generated for convective hex/wedge elements.
Main Index
104 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Input Properties
Main Index
105
Loads and Boundary Conditions
Main Index
106 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
The following table outlines the options when the Analysis Type is set to Thermal.
Main Index
107
Loads and Boundary Conditions
Main Index
108 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
The following specifies the defined variables which are used to specify the Boundary Condition ID. By
using the variable name the specific ID can be assigned in a define statement and only needs changing at
one location in any special PCL one may write using the defined boundary conditions.
Main Index
109
Loads and Boundary Conditions
Main Index
110 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
Main Index
111
Loads and Boundary Conditions
Input Data
This subordinate form appears when the Input Data button is selected and Static is the Load Case Type
selection (the only Load Case selection currently supported). For Patran Thermal boundary conditions
are not specified separately for steady state and transient conditions which are defined in the analysis
Main Index
112 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
form. Thus the distinction between static and dynamic load case has no meaning. The information
contained on this form will vary according to the selected Object.
All boundary condition options which do not contain the word “Template” involve direct translation and
the information is not written to the neutral file. All the boundary condition information is complete
within the Patran model and does not require any supplementary information to complete the input to the
solution module. However, all options which contain the word “Template” translate information passed
through the neutral file and many case requires additional information which is defined through a
template file. The actual translation is done external to Patran. This template file can be built
independently or with the template builder available in the analysis menu.
Defined below is a typical form for Convection (PThermal) as the Object and Fixed Coefficient as the
Option.
Main Index
113
Loads and Boundary Conditions
Spatial Fields
Main Index
114 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
All of the non-template convection options have two selection regions for determining where the
convection boundary condition is to be applied (Application Region) and the corresponding fluid node
(Coupling Region).
Time Table
Input Data form when Time Table option is selected.
Main Index
115
Loads and Boundary Conditions
Fixed Option
Following are the input forms for the convection template option.
Main Index
116 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
Main Index
117
Loads and Boundary Conditions
Gap Radiation
Gap Radiation is used for all radiation between entities is not strongly influence by view factor
considerations.
Main Index
118 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
General Radiation
General Radiation considerations are calculated with P/VIEWFACTOR. The boundary conditions are
defined through enclosure IDs and template information. Each enclosure is treated as a separate entity
but may have several boundary conditions associated with it. Each material is identified by its own
Template ID and different surface characteristics can be further separated by different boundary
conditions.
Main Index
119
Loads and Boundary Conditions
Template Definitions
For variable boundary conditions, Patran Thermal uses a pointer system called a Template ID to
reference more data contained in an auxiliary file. This external file is named template.dat.apnd
and is created using forms on the analysis menu or the system editor in the same directory level as the
Patran database. When a job is submitted from Patran, the template.dat.apnd file (if it exists) will
be appended to the template.dat file created automatically in the sub-directory with the Job Name.
In the current release of Patran Thermal, Template IDs are required for all boundary conditions with
“Template” in the option name. The following table shows boundary condition data types, Template
Name and applicable field types.
Main Index
120 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
Object Tables
On the input data form, there are areas where the load data values are defined. The data fields presented
depend on the selected Object and Type. In some cases, the data fields also depend on the selected Target
Element Type. These Object Tables list and define the various input data which pertain to a specific
selected object:
Main Index
121
Loads and Boundary Conditions
Temperature (PThermal)
Main Index
122 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
Main Index
123
Loads and Boundary Conditions
Convection (PThermal)
Object Type Target Option
Convection Element Uniform 1D, 2D, 3D Template, Convection
Element Variable
Note: Filter must be the same (either Geometry or FEM) on both application regions.
Main Index
124 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Loads and Boundary Conditions
Heat Flux
Object Type Target Option
Heating Element Uniform 1D, 2D, 3D Template, Fluxes
Element Variable
Nodal Heat
Object Type Option
Heating Nodal Template, Nodal Source
Volumetric Heat
Object Type Target Option
Heating Element Uniform 1D, 2D, 3D Template, Volumetric Heat
Element Variable
Pressure
Object Type Option
Pressure Nodal Template, Fixed, Initial
Main Index
125
Loads and Boundary Conditions
Mass Flow
Object Type Option
Mass Flow Nodal Template,
Fixed,
Initial
Radiation (PThermal)
Object Type Target Option
Radiation (PThermal) Element Uniform 1D, 2D, 3D Gap Radiation
Note: Filter must be the same (either Geometry or FEM) on both application regions.
Viewfactor
Object Type Target Option
Radiation Element Uniform 1D, 2D, 3D Viewfactor
Main Index
126 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Load Cases
Load Cases
Patran Thermal does not currently support Load Cases. All the boundary conditions must be entered in
the Default load case for both steady state and transient runs. This load case is automatically selected
when the analysis is submitted from the Analysis Form.
Note: Use of Load Cases in the Patran Thermal model can cause unexpected results.
Main Index
Chapter 4: Module Operation
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
4 Module Operation
Main Index
128 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Preference Files
Preference Files
If Full Run is set, the Apply selection in the Analysis form will create the appropriate interface files and
execute the solver. The interface files created include:
• A neutral file
• The analysis control files qin.dat and vf.ctl
• The script for executing the model patq.inp
• The material property file mat.dat and template.dat
• The field definition file micro.dat
The user has control of which files are created and how the execution is to proceed through the
parameters in the Submit Options form. These submit parameters have been defaulted for new jobs. With
Patran Thermal, multiple jobs can be created from the same Patran database. The model files will appear
in subdirectories named with the jobname that was entered in the Analysis form.
Patran Thermal is designed to support the functionality in P/THERMAL including the View factor code,
the coupled thermal/hydraulic networks, creation of a SINDA input deck, both forward and reverse
translation of enclosure tria and quad surfaces to the TRASYS and NEVADA codes.
Main Index
Chapter 4: Module Operation 129
Reference Notes
Reference Notes
These notes are a supplement to the PAT 312 Patran Thermal class and are intended to answer the most
commonly asked Patran Thermal questions.
Set up
1. The FORTRAN & C programming languages must be loaded on the workstation that will be used
for running the thermal solution (not required for the Patran SINDA translator).
2. The environmental variable PATH must include the location of FORTRAN 77 (F77), CPP
compilers and related libraries. Type echo $PATH in the UNIX window to verify the PATH
variable.
3. Copy the file p3epilog.pcl from the Patran installation directory to your home directory.
Every time you enter Patran, an additional pull down menu called “Shareware-Thermal Tools”
will be available to simplify building and verifying Patran Thermal models. This can be
accomplished as follows:
% cd
% cp
<inst_dir>/patran3/shareware/msc/unsupported/utilities/p3epilog.
pcl.
where <inst_dir> is the installation directory for your Patran executables.
Model Creation
Loads & Boundary Conditions
Main Index
130 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Reference Notes
Fill out the spreadsheet of Independent Variable (time) vs. Dependent Variable (temperature) data.
Select OK and Apply.
Select the Loads/BCs Button.
Set the Action-Object-Type to Create-Temperature(PThermal)-Nodal.
Set the Option to Variable.
Select the Input Data button.
Input Temperature Scale Factor of “1” and enter a Template ID of 1 for your first varying temperature
boundary condition.
Enter the desired node(s) in the Select Application Region subform and select Apply.
In the same directory where the database exists, create a file called template.dat.apnd. All
information in this file will be copied to the template.dat file in the job name subdirectory when the
job has been submitted.
Enter the following information into the template.dat.apnd file:
MACRO 1 1 0 0 1.0
1
where the “1” following the keyword MACRO refers to the template ID that you entered in the
Loads/BCs Input Data form. The “1.0” is a scale factor for the temperatures and the “1” on the second
line refers to the microfunction ID that you specified in the Micro Function ID (MFID) databox in the
Fields form.
If you have two time varying boundary conditions, then you would add two additional lines as follows:
MACRO 2 1 0 0 1.0
2
Note that comment cards in this file begin with the character “*”.
See class problem number 5 for an example of this process.
Main Index
Chapter 4: Module Operation 131
Reference Notes
To enter a table of time vs. temperature data, set the Select Function Term to mfid_linr_indx_table
which stands for microfunction of linear indexed table.
Enter a Micro Function ID (MFID) to a number that you will reference in the template.dat.apnd
MACRO template. You can modify the default number to a number (3 for example) that matches the
MACRO number you will use in the Loads/BCs form.
Fill out the spreadsheet of Independent Variable (time) vs. Dependent Variable (heat) data.
Select the Loads/BCs Button.
Set the Action-Object-Type to either
Create-Heating(PThermal)-Nodal.
Set the Option menu to either Nodal Source, Fluxes, or Volumetric Generation.
Select the Target Element Type as appropriate.
Select the Input Data button.
Input Loads/BC Scale Factor “1” and enter a Template ID of 3 (arbitrary) for a varying heat boundary
condition.
Enter the desired node(s) (or element(s) for Flux and Volumetric Generation) in the Select Application
Region subform and select Apply.
In the same directory where the database exists, create (or open) a file called template.dat.apnd.
All information in this file will be copied to the template.dat file in the job name subdirectory when
the job has been submitted.
Enter the following information into the template.dat.apnd file:
MACRO 3 1 0 0 1.0
3
where the “3” following the keyword MACRO refers to the template ID that you entered in the
Loads/BCs Input Data form. The “1.0” is a scale factor for the temperatures and the “3” on the second
line refers to the microfunction ID that you specified in the Micro Function ID (MFID) databox in the
Fields form.
If you have two time varying boundary conditions, then you would add two additional lines as follows:
MACRO 4 1 0 0 1.0
4
Note that comment cards in this file begin with the character “*”.
Main Index
132 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Reference Notes
The “CONV” is a keyword for convection templates. The first “1” is the template id supplied in the
Loads/BCs Input Data form. “29” denotes the convection configuration for time or temperature varying
convection as described in the documentation. “0” denotes the number of geometric properties (GPs)
supplied by this template, and the last “1” is the number of MPIDs for the configuration. This MPID is
given on the next line & is arbitrarily given the number “5001”.
The number of GP values defined by the template is zero in this case because the correlation only requires
the nodal subarea which is supplied by Patran and PATQ during the translation process.
In the same directory where the database and template.dat.apnd file exist, create (or open) a file called
“mat.dat.apnd”. All information in this file will be copied to the “mat.dat” file in the job name
subdirectory when the job has been submitted.
Enter the table into the “mat.dat.apnd” file as follows:
Main Index
Chapter 4: Module Operation 133
Reference Notes
MDATA 0. .9
MDATA 1. 1.1
MDATA 1.5 1.15
MDATA 2.0 1.4
MDATA 4.0 1.8
/
The MPID is a keyword for material property id. The “5001” refers back to the “5001” given in the
template.dat.apnd file. “ITABLE” denotes that this is an indexed table which means that Patran Thermal
starts the search in this table where it left off in the last time step and is therefore faster than the
“TABLE”.
Any input other than “MDATA” or “/” after an MPID keyword is assumed to be a comment. For this
example, the “Convection Coefficient (Btu/hr-ft^2-F) as a function of Time (seconds)” is a comment that
describes this table.
The “/” is required at the end of each MPID input.
To input this table of convection coefficient as a function of temperature, use the keywords “Fahrenheit,”
“Rankine”, “Celsius”, or “Kelvin” in place of the keyword “Time”.
Contact Conductance
Select the Loads/BCs button and set the Action-Object-Type to Create-Convection(PThermal)-
Element Uniform. Set the Option to Between Regions. When selecting the Application Region, set
the Order to Closest Approach. To create contact conductance between two geometric solid faces that
contact each other in the Patran model, both application regions should be element based (such as setting
Region 2 to 3D). If Nodal is selected for Region 2, and a surface or face of a solid geometric entity is
selected, Patran will fill the listboxes with the nodes from both contacting faces even if only one face is
selected (an error will flag this when selecting the Analysis Apply button).
Radiation
PCL that creates the radiation boundary condition and eliminates the need for editing the
“template.dat.apnd” file for viewfactor templates exists and will be included on the Shareware pulldown
menu as described above.
or
Select the Loads/BCs button and set the Action-Object-Type to Create-Radiation (PThermal)-
Element Uniform. Set the Option to View Factors
Main Index
134 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Reference Notes
Enter a New Set Name that describes this boundary condition. Set the Target Element Type to 2D for
plate elements or 3D for solid element faces.
Select the Input Data button.
Leave the Loads/BC Set Scale Factor at 1 (this is not a viewfactor scale factor!). Input a viewfactor
Template ID value (1 for example). This is a pointer to the template.dat.apnd file. Leave the
Participating Media Node databox empty. If your model is not completely enclosed, enter the ambient
node into the Ambient Node Id databox. Viewfactors that do not see any portion of your model will see
the temperature of this node (fixed or variable). The viewfactor code will not attempt to calculate
viewfactors for all elements with the same Convex Set Id (any integer number). The Obstruction Flag
databox is another CPU saving feature that can be left empty. The default viewfactor direction will be
applied in the element normal direction. Under the Finite Elements Verify-Element-Normal form,
arrows can be displayed in the element normal direction. If the opposite direction is desired, Enter “1” in
the Top/Bottom Flag databox to apply the viewfactor boundary condition in the bottom direction. In
order to have radiation off of both faces of a plate element, two viewfactor applications must be applied,
one with the Top/Bottom Flag empty (or set to “0”), and the other with the flag set to “1”. The last
databox is the Enclosure Id. Only viewfactors with the same Enclosure Id have the possibility of seeing
each other.
Select Application Region, select the FEM button and select the desired elements. Select OK & then
Apply.
In the same directory where the database exists, create (or open) a file called template.dat.apnd.
All information in this file will be copied to the template.dat file in the job name subdirectory when
the job has been submitted.
Enter the following information into the template.dat.apnd file:
Note that comment cards in this file begin with the character “*”
“VFAC” is a keyword to signify viewfactor template. The first “1” is the template id that you supplied
in the Loads/BCs Input Data form. Assuming you are not performing spectral analysis (emissivity
varying with wavelength), then the"# of bands” is zero.
The second line (of non-comment input) starts with the emissivity. This is the only required input for this
line. The “collapse” flag at the end of this line is beneficial in reducing the size of your radiation network
by up to a factor of 16. The “tau” is the transmissivity and is set to “1” unless you have a participating
media. The “emis. MPID” is the material property ID for variable emissivity. Set this to zero for fixed
emissivity. The same is true for “tau MPID”. Since this is not a spectral problem, “band1”, “band2”, and
“kflag” are set to “0”. All element viewfactors with the same “collapse” flag ID will be condensed.
Main Index
Chapter 4: Module Operation 135
Reference Notes
Materials
Varying with Temperature
If you wish to use the materials from the Patran Thermal library, use the Shareware-Thermal Tools pull
down menu item P/Thermal Materials List. Input the name of the material of interest, such as “alu” to
get a listing of all materials in the Patran Thermal material library that contain the characters “alu”. To
use this material in your model, you may skip the Materials form entirely and input this material ID in
the Element Properties, Input Data form in the Material listbox
To input your own materials that vary with temperature, Select the Fields button from the main menu,
and set the Action-Object-Method to Create Material Property General. Enter a descriptive name for
this field, and select Input Data. Select the desired option for you field. For a table, select
mpid_indx_linr_tabl. Now you can enter a table of temperature versus material property (i.e.
conductivity, etc.). Be sure to select Apply after completing input for each table
This information will get written to your jobname directory into a new mat.dat file when you submit
your job.
All other material properties can be input from the Materials form selected from the main form.
Element Properties
For 3 dimensional models (vary in x, y, and z), be sure to use the Action-Dimension-Type of Create-
2D-Shell for plate elements (quads or trias). Release 1.4 no longer requires the input of four thickness
values for each corner.
For the case where a model is 2 dimensional (all of model is constructed in x-y plane) and is assumed to
have unit depth thickness in the z-direction, use the Action-Dimension-Type of Create-2D-Thermal
2D for plate elements. Since unit depth is assumed, no input of element thickness is input.
Load Cases
Load cases are not supported for Patran Thermal. Create all of the loads and boundary conditions in the
default loadcase.
Main Index
136 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Reference Notes
Results Verification
Job Submittal Status
To verify that your job submittal was successful, examine the patq.msg files and look for error
messages. If you are running a viewfactor job, you can check the status by examining the vf.msg
message file.
Note that the shareware pull down menu has a Translation Status option that examines the contents of
the patq.msg file for you.
Temperature Convergence
In the jobname directory, enter the command qstat or qstat -b. qstat will give the status of your
job while (and after) it's running. Check to make sure that the temperature change between iterations is
decreasing and is approaching 1.e-05 for convergence with the default parameters. If your model has not
converged after 1999 iterations (the default maximum allowable for steady state as displayed by qstat),
verify that your material properties are correct. Note that the convergence criteria is based on the slope
of the model convergence and not a simple iterative delta in temperature.
The Patran Thermal Tools pulldown menu has a Thermal Convergence Status option that makes x-
y plots of the convergence status. Be sure to use the Clear button when finished viewing these plots to
clear the windows for the next time you wish to check the status.
Main Index
Chapter 4: Module Operation 137
Reference Notes
the output requests form to include all eight output options. You can resubmit the job for one iteration to
get a new result file.
Results Display
From the jobname directory, enter the UNIX command:
% ls -rt nr*
to get a listing of the nodal result files in reverse time order. The last file should be read in for a steady
state analysis. This command is important as the following example illustrates.
Run 1: Material properties were input in meters instead of millimeters for one of the materials. The job
never converges and give output files every 500 iterations; nr0.nrf.1, nr1.nrf.1, nr2.nrf.1, nr3.nrf.1.
Run 2: Material property corrected and job converges in 27 iterations resulting in nr0.nrf.2.
Then the Analysis form is selected and the Action is set to Read Results, Select Results File. After
selecting the jobname directory, which will filter on the nr* files, the last one listed is nr3.nrf.1
(from UNIX alphanumeric sorting). However, the nr0.nrf.2 file should be selected if the most
recent result is desired.
Next, select the Select Rslt Template File button, scroll towards the bottom and pick the last pthermal
result template (pthermal_nod_T.res_tmpl) and select apply. This result template allows for all 8 result
values that may have optionally been selected within the Output Requests-Nodal Results File Format
form before the job was submitted. If only temperature was requested in the output files (default) then
the remaining values of net nodal heat flux, etc. will be zero.
Select Results and display the fringe plot.
Main Index
138 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Reference Notes
Main Index
Chapter 5: Running an Analysis
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
5 Running an Analysis
Main Index
140 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Review of the Analysis Application
Main Index
Chapter 5: Running an Analysis 141
Analysis Form
Analysis Form
This form is used to set up the parameters for the analysis, and will submit the job to the Patran Thermal
solver.
Restart File
Pthermal can be restarted with initial temperatures based on a nodal results file from a previous
execution. If a nodal results file is specified it will be used to define initial temperatures for the new run.
If it is desired to continue with a given file numbering sequence, it can be specified. The time of the restart
file will be the new time associated with the current analysis unless the user defines a new time. The
Main Index
142 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
restart case will ignore the temperature specifications unless one flags that the initial temperatures are to
over write the restart temperatures.The new initial temperatures can be for any of the nodes.
Translation Parameters
This subordinate form appears when the Translation Parameters button is selected on the Analysis form.
Main Index
Chapter 5: Running an Analysis 143
Analysis Form
Solution Type
This subordinate form appears when the Solution Type button is selected on the Analysis form.
Main Index
144 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Solution Parameters
This subordinate form appears when the Solution Parameters button is selected on the Analysis form.
Main Index
Chapter 5: Running an Analysis 145
Analysis Form
This subordinate form appears when the Maximum Time Step button is selected on the Run Control
Parameters form.
Main Index
146 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
This subordinate form appears when the Maximum Time Step button is selected on the Run Control
Parameters form.
Main Index
Chapter 5: Running an Analysis 147
Analysis Form
Convergence Parameters
This subordinate form appears when the Convergence Parameters button is selected on the Solution
Parameters form.
Main Index
148 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Iteration Parameters
This subordinate form appears when the Iteration Parameters button is selected on the Solution
Parameters form.
Main Index
Chapter 5: Running an Analysis 149
Analysis Form
Relaxation Parameters
This subordinate form appears when the Relaxation Parameters button is selected on the Solution
Parameters form.
Main Index
150 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 151
Analysis Form
Main Index
152 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 153
Analysis Form
Output Request
This subordinate form appears when the Output Request button is selected on the Analysis form.
Main Index
154 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 155
Analysis Form
Main Index
156 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 157
Analysis Form
output and calculation temperatures and the default material properties to be used. Only labels that were
selected for output entities can be edited and written to the results template file.
Main Index
158 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 159
Analysis Form
Diagnostic Output
This subordinate form appears when the Diagnostic Output button is selected on the Output Request
form.
Main Index
160 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 161
Analysis Form
Submit Options
This subordinate form appears when the Submit Options button is selected on the Analysis form.
Main Index
162 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 5: Running an Analysis 163
Delete
Delete
This form is available when the Action on the Analysis form is set to Delete. This can be used to delete
jobs from the database, revert a job to default values or create a new job starting with the default values.
Main Index
164 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
Template Generator
This form appears when the Action is set to Build Template on the Analysis form.
Main Index
Chapter 5: Running an Analysis 165
Template Generator
MID
Main Index
166 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
MACRO
Main Index
Chapter 5: Running an Analysis 167
Template Generator
CONV
Main Index
168 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
VFAC
Main Index
Chapter 5: Running an Analysis 169
Template Generator
Main Index
170 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
Main Index
Chapter 5: Running an Analysis 171
Template Generator
FLUID
Main Index
172 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
Read
The Read action allows the user to read in existing template data from an external file. The extension of
the template file (either .apnd or .dat) is indicated by setting the Template File Type switch. The Template
File… button is used to specify the name of the template file to be imported. Once the Apply button has
been hit the template entries are placed in the template file spreadsheet for viewing.
If the Sort Entries toggle is set to ON, the template entries are sorted first by type (i.e., all MID, MACRO,
CONV, etc. entries are placed together) and then by ID within each type (i.e., MID 5, MID 10, MID 25,
etc.).
Main Index
Chapter 5: Running an Analysis 173
Template Generator
Main Index
174 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template Generator
The contents of a spreadsheet cell may be modified by selecting the cell and changing the contents of the
Input Data databox. A comment line is indicated by placing a * in the first character of the first cell of a
row (note: all other cells in that row will be ignored in this case). The comment text follows the asterisk.
Clicking on any cell will result in the contents of the cell being displayed under the spreadsheet. This
allows for viewing of long text comment strings.
Toward the bottom of the spreadsheet, information labels indicating the number and type of defined
template entries are displayed.
The Write File button allows the user to write the spreadsheet contents to an external file. A file may be
appended or a new file generated (Note: It is recommended to import a template file, add/modify entries
and then export a new file rather than append to an existing file.) by selecting the Append File/New File
switch above the Write File button. Once the Write File button has been selected, the user will be
prompted for the filename to write to; selecting the OK button results in file output.
All spreadsheet contents may be cleared using the Clear button. This action is irreversible (the user is
prompted to verify that this was the intended action) in that once the spreadsheet is cleared, the entries
may not be retrieved but must be recreated from scratch or imported from an external file.
Main Index
Chapter 5: Running an Analysis 175
Thermal Tools
Thermal Tools
Several of the PCL shareware tools for Pthermal have been moved to Pthermal’s Analysis Form when
the action selected is Thermal Tools. Most of these function perform just as they did in the past except
for the convenience of getting to them.
Main Index
176 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Thermal Tools
Main Index
Chapter 5: Running an Analysis 177
Thermal Tools
Main Index
178 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Thermal Tools
Main Index
Chapter 5: Running an Analysis 179
Thermal Tools
Main Index
180 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Thermal Tools
Temperature Interpolation
The temperature interpolation function does????
Main Index
Chapter 5: Running an Analysis 181
Thermal Tools
Main Index
182 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Thermal Tools
Main Index
Chapter 5: Running an Analysis 183
Plot View Factors
Main Index
184 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
Main Index
Chapter 5: Running an Analysis 185
Plot View Factors
2. Number of Surfaces
3. Dimension Code
4. Surface Offset
5. Maximum Surface ID
6. Maximum Number of Nodes per Surface
This information applies to one enclosure and will become initial values for subsequent enclosures. The
dimension code is defined ( p 143 view factor manual ). The surface offset is adjusted such that a surface
ID can be easily identified. The maximum surface ID will be used as the seed offset for the next
enclosure.
Main Index
186 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
Main Index
Chapter 5: Running an Analysis 187
Plot View Factors
Main Index
188 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
Main Index
Chapter 5: Running an Analysis 189
Plot View Factors
Main Index
190 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
Main Index
Chapter 5: Running an Analysis 191
Plot View Factors
3. The Domain should be set to None if the element file is to be used so that the true view factor for
each element is plotted. If the contour plots are desired set the Domain to All Entities if the
continuous option is used.
The fringe selection forms are shown below.
Following are some examples of view factor plots. The example is two parallel plates one unit on a side
and 0.6 units apart. For this case the view factor to space is greater than it is to the other plate for each
element.
Main Index
192 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
A plot from a single surface to all other surfaces is shown below in the element file mode. Note that the
sum of all view factors is from the single surface to all other surfaces is included in the title.
Main Index
Chapter 5: Running an Analysis 193
Plot View Factors
Main Index
194 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
A sample of the output is shown below. The surface list for each group is defined in the output. The total
surface area for the from surface and the resulting view factor between the groups is defined. A second
set of area and view factor is shown. This is the total surface area of all elements in the enclosure and the
sum of all view factor area products in the enclosure. For a totally enclosed system the total sum for area
and area view factor product should be one. The individual view factor from the “from group” to each
individual surface is output. A partial table is shown below. The Surface ID that is defined by radiating
surface with the given offset and its corresponding element ID for the view factor specified in the first
column. The next surfaces continues incrementing by one for the next columns on that given row. There
is no break on a row if the numbering has gaps. For example surface 1121 begins with element 121.5
(where .5 indicates the top of a surface) begins in the first column. Element 210.6 is shown in the second
column, but the element ID is not consistent with the surface ID until the next row. The file below is only
representative and does not include all columns or rows.
Main Index
Chapter 5: Running an Analysis 195
Plot View Factors
Main Index
196 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Plot View Factors
Main Index
Chapter 6: Reading Results
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
6 Reading Results
Main Index
198 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview of Results Import
Main Index
Chapter 6: Reading Results 199
File Menu Import
When the Import option is selected and Analysis Preferences is set to Patran Thermal, the analysis
specific Import form appears. See Import Form, 199 for more information.
Import Form
When results are imported in this manner, the entire file is input into the database. If selective results
types are desired in the database, then the Analysis Form, 201 Read Results approach must be used.
Main Index
200 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
File Menu Import
Main Index
Chapter 6: Reading Results 201
Analysis Form
Analysis Form
The Read Results Analysis form can be used to read results from a Patran Thermal analysis by setting
the Action to Read Result.
Main Index
202 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Analysis Form
Main Index
Chapter 7: Thermal/Hydraulic Theory
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
7 Thermal/Hydraulic Theory
Main Index
204 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
Network Methods
This section provides an introduction to network concepts, techniques, and terminology. Network analog
methods are discussed for thermal problems which involve conduction, convection, gray-body radiation,
wavelength-dependent radiation, advection (mass flow), heat sources, or temperature sources.
Recommendations for certain problem types are also presented.
(E[1] – E[2])
I [ 1 → 2 ] = ------------------------------------ (7-1)
R
Q [ 1 → 2 ] = (-----------------------------------
T[1] – T[2])
- (7-2)
R
For transient current or heat flows, flow into an electrical or thermal capacitor must be included. For
current flow I into an electrical capacitor, the equation is:
dE
I = ------- * C (7-3)
dt
where C is the value of the electrical capacitor and dE/dt is the time derivative of the voltage across the
capacitor. In heat transfer, the analogous equation for heat flow into a thermal capacitor is:
dT
Q = ------- * C (7-4)
dt
Main Index
Chapter 7: Thermal/Hydraulic Theory 205
Network Methods
Note: One convenient feature concerning thermal capacitors is that one node of the capacitor is
always “grounded.” This contrasts with electrical capacitors, where an electrical capacitor
may be connected to two separate voltage nodes and is not necessarily grounded. This
forced grounding of thermal capacitors simplifies thermal networks and thermal network
calculations (relative to electrical networks) considerably.
The parallels between electrical and heat transfer equations have led to the development of the thermal
network concept. The remainder of this section defines more completely thermal network concepts,
especially as they apply to the QTRAN thermal network program. QTRAN has taken the conventional
thermal network concepts and has added to them vis-a-vis wavelength-dependent thermal radiation
resistors, the three-node convective resistors, LaGrange cubic finite element resistors, and others. For
those who are more comfortable with finite element concepts, it might be easier to think of a thermal
resistor as a 1-D finite element. Another viewpoint is to simply think of the thermal resistors as
computational molecules or numerical models, especially where normal thermal resistor concepts do not
strictly apply (e.g., the three-node convective resistors and wavelength- dependent resistors).
Conduction Networks
This section briefly outlines the fundamentals of the electrical network analog approach for conduction
networks. It includes multidimensional transient and steady-state network models and the associated
mathematical relations which govern them.
Length
R = ------------------------------- (7-6)
( k * Area )
and the heat conducted from node 1 to node 2 is computed from the following expression:
Q [ 1 → 2 ] = (-----------------------------------
T[1] – T[2])
- (7-7)
R
Main Index
206 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
where:
Note: The conductance, G, is the reciprocal of the resistor value, R. For one dimension, a
conduction problem consists merely of a string of conductive resistors going from node to
node. For 2-D and 3-D, a conduction problem consists of a network of these resistors going
from node to node in all three dimensions.
Transient Conduction
Transient conduction involves the added complications of capacitors, where a single capacitor value is
defined as follows:
C = ρ ⋅ Volume ⋅ C p
If the node in question lies at a material interface, it may be convenient to assign one capacitor to the node
for each material at the interface. The heat equation being solved for transient conduction at a given node
[i] is then seen to be:
all all
T[j] – T[i]
∑ C [ i, n ]dT [ i ] = ∑ ---------------------------
R [ i, j ]
- dt (7-8)
n=1 j =1
which states the sum of all the capacitances multiplied by the time derivative of node [i] is equal to all of
the heat flows across all resistances into the node.
Important:Since QTRAN uses implicit integration, stability considerations are not required. However,
the maximum stable time steps for an explicit forward Euler algorithm would be given by
the following expression:
all
∑ C[K]
K=1
dt [ maximum stable explicit ] = -------------------------- (7-9)
all
∑ G [ i, j ]
j= i
While the maximum stable time step in the system does not affect QTRAN’s stability, it may have an
effect on the execution time. In general, the smaller the stable time step the more time a given problem
Main Index
Chapter 7: Thermal/Hydraulic Theory 207
Network Methods
may take to execute. A network with tiny stable time steps tends to generate stiff systems of equations
which are more difficult to solve than non-stiff systems. However, a network whose nodes have
predominantly small stable time steps will also give better resolution in the time domain to fast transients,
especially at very early times in the simulation. A rule of thumb for the mesh spacing (which directly
affects the explicit stable time step) is to compute the approximate mesh spacing from the following
formula:
α * time [ i ]
dx < ---------------------------- (7-10)
5
time [ i ] earliest time point of interest (e.g., first print dump for a transient problem
This is an extremely approximate formula and you can typically violate it by a factor of several. If
violated by orders of magnitude, however, the results may be in serious error. The formula given can be
arrived at from several approaches. One approach is to look at the most significant term of a 1-D
conduction solution which is an infinite series. Another approach is to look at response times and decay
rates of exponentially damped dynamic systems. Try it out and see what results are obtained. Review past
analyses that have been performed and compare the mesh spacing to this criteria.
Although this mesh spacing criteria is important in regions undergoing rapid change, this criteria can
typically be grossly violated in regions where the transient is very mild.
1n (R [ outer ] ⁄ R [ inner ])
R [ cylinder ] = ------------------------------------------------------------------ (7-11)
2 * π * k * Length
R [ outer ] – R [ inner ]
R [ sphere ] = --------------------------------------------------------------------------------------- (7-12)
4 * π * R [ outer ] * R [ inner ] * k
Main Index
208 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
Convection Networks
Convection networks can be a source of great anxiety. They tend to embody an empirical convection
coefficient h in the convective resistors, and the formulas used to compute this h value are usually highly
Main Index
Chapter 7: Thermal/Hydraulic Theory 209
Network Methods
complex. Transition regimes also frequently exist, where the empirical correlation used for a particular
configuration may be a function of Reynolds, Grashoff, Rayleigh, Prandtl, Graetz, and add infinitum
number ranges.
For example, the pipe flow configuration in QTRAN uses five different correlations with seven factorial
transition regimes based on everything from Reynolds number ranges to viscosity ratio ranges. Also,
since the correlations are not in general continuous through the transition regimes, interpolation must be
used when in a transition regime to maintain continuity and avoid numerical convergence problems.
Further complications arise when mass flow through tubes or packed beds occur, as three temperatures
are then needed. The following sections expand on these concepts.
1
R = ---------------------------- (7-13)
( h * Area )
where:
R is the thermal resistance, h is the convection coefficient, and Area is the surface area from which heat
is being convected. The heat flow across the resistor is then given by:
Q [ 1 → 2 ] = (-----------------------------------
T[1] – T[2])
- (7-14)
R
The tricky detail of this operation, of course, is to compute an h value for the resistance expression. In
general, empirical correlations must be relied upon. These correlations are usually somewhat tedious to
evaluate, since they themselves are in general a function of temperature and/or temperature difference.
Furthermore, each correlation is usually only applicable to a range of dimensionless parameters, and
hence these parameters must be evaluated to determine which correlation to use for a given configuration.
The result is a very painful (if done by hand) iterative solution for even a relatively simple convection
problem.
QTRAN alleviates the pain somewhat by offering a convection library from which the user may select
any one of 37 configurations which are in turn supported by 61 correlations (several generic correlations
also exist). QTRAN will automatically and dynamically select the appropriate correlation for both the
configuration type and the dimensionless parameter range for the resistor. A catalogue of available
configurations is contained in Convection Library (Ch. 9) along with a catalogue of supporting
correlations. All correlations are fully documented and referenced such that the user may easily locate
the references from which the correlations were taken.
Main Index
210 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
a third temperature node with the convective resistor. Configurations CFIG = 1, 2, and 21 are pipe flow
configurations and CFIG = 25 is a flow through porous media configuration. For all four configurations,
three temperature values are needed. The three temperatures needed are:
1. a wall (or media) temperature
2. an upstream temperature
3. a downstream temperature
It is at this point that the computational hydrodynamics concept of “upwind differencing” must be
introduced. Upwind differencing is a numerical technique that is used to maintain stability for a
numerical solution which involves advection. Simply stated, upwind differencing assumes that
information (in this case, heat) is carried only from upstream to downstream. Information (or heat) is
never carried from downstream to upstream. The impact of upwind differencing on the three-node
convective resistors is that the upstream node NEVER gains or loses heat through the convective resistor
so long as the flow velocity associated with the resistor remains positive.
Thus, it is seen that all heat transfer through the three-node convective resistors occurs between the wall
(or media) node and the downstream node. The upstream node is used solely as a reference temperature
node for LMTD calculations (if appropriate) so long as the flow velocity is positive. The LMTD is used
for those flow configurations for which it is appropriate, and a differential between the wall temperature
and the average bulk fluid temperature is used for other configurations.
From this discussion, it is obvious to the casual observer that the three-node convective resistors do not
account for advective heat transfer (i.e., the heat carried along on the mass flow). In order to complete a
thermal model involving a three-node convective resistor, it is frequently necessary (depending on the
boundary conditions of the problem) to use an advection resistor to properly account for the heat balance.
Another point that may not be quite so obvious is that the three-node convective resistors may not be
directly used to compute entrance temperatures given that the wall (or media) and exit temperatures are
known. Remember that the heat transfer to the upstream node is not a function of a the three-node
convective resistor since the upstream node is used only as a reference temperature. The upstream node
temperature must be taken from boundary conditions or else calculated from other thermal resistor,
capacitor, and heat source influences.
Note: There is no current way of assigning 3-noded convective resistors from Patran. To use any
of the 3-noded configurations, they will have to be assigned manually.
Main Index
Chapter 7: Thermal/Hydraulic Theory 211
Network Methods
The formula for radiative heat transfer used in thermal networks in QTRAN is as follows:
4 4
σ * ( T [ 1 ] – T [ 2 ] )-
Q [ 1 → 2 ] = ---------------------------------------------------- (7-15)
R
The formula for R is dependent upon whether R is a surface resistor, a view factor resistor with or without
a participating media, and so on. The actual formulation of the specific resistor types is defined after
Table 8-1 and Table 8-2 for gray body and wavelength dependent radiation respectively.
For more information on radiative networks, consult any radiative heat transfer book that describes the
network approach. See Ref. 6. in Appendix A.
The gap radiation creates radiation coupling without the radiosity network or performing form factor
calculations. Some assumption inherent in the formulation are that the area radiating is large relative to
the distance between the radiating surfaces. A form factor may be included, but if it is significantly less
than one, consideration should be given to using the radiosity network and calculating the appropriate
form factors. Type 5 radiation resistors are used thus the emissivities must be constant. Type 5 resistor
are constant and are treated internally as conductances. The last major assumption is that the two surfaces
radiating to each other are of equal value. Since a form factor is included, small variation can be
compensated for by adjusting emissivity or form factor values. The radiation conductance is determined
with (7-16)
1 A1
C = ---- = A F = -----------------------------------------------------
- (7-16)
R 1 12 ------
1 1 1
+ ------ + ----------- – 2.0
ε ε F
1 2 12
Advection Networks
Advection occurs whenever some quantity is carried along on a mass flow stream. For example, if hot
fluid enters a container, heat (energy) is carried with the fluid into the container. Similarly, if a cold fluid
enters a hot container, cold (or negative energy) is carried with the fluid into the container. This transfer
of positive or negative energy by mass flow must be accounted for when doing thermal simulations if
Main Index
212 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
such mass flows exist. The mathematical equation for the heat added to node [i] by such a mass flow
stream is as follows:
Q [1→2]=MDOT * Cp * ( T[1] - T[2] ) (7-17)
Q [1→2] the amount of energy transported by the mass flow from node #1 to
node #2
MDOT the mass rate of flow from node #1 to node #2
Cp the specific heat of the flowing mass
Note: QTRAN evaluates the specific heat as the integration between the temperatures of node #1
and node #2 using the temperature increment defined by CPDELT.
One facet of numerical stability should be mentioned at this point because of its influence on advective
resistors. It is necessary to limit the transport of energy by advective resistors to one direction only for
the purposes of the QTRAN program. Specifically, energy is carried by advective resistors only from the
upstream node to the downstream node (which node is upstream or downstream is determined by the sign
of the MDOT mass flow term). This scheme is immediately seen to be equivalent to one-sided or
“upwind” differencing which is a common practice among numerical fluid flow analysts, and is
commonly used because of its stability enhancing characteristics.
By introducing upwind differencing, we can guarantee that the system of equations has a stable solution.
This does not mean, however, that the SNPSOR algorithm in QTRAN can always solve the system of
equations. This is due to the point iterative nature of the SNPSOR algorithm. As long as the system of
equations is diagonally dominant, point iterative schemes tend to work very well. However, the
introduction of advection tends to weaken this diagonal dominance. As the diagonal dominance weakens,
point iterative methods have more and more difficulty converging, until they eventually fail. One way of
aiding convergence (at the expense of speed) is to under-relax. With a small enough relaxation parameter,
a solution will usually converge. However, be aware that CPU times increase rapidly as the relaxation
parameter approaches 0.0.
The user has the option of applying the relaxation parameters to the entire system of equations, by node
group types, or on a node by node basis. To under relax, apply the under relaxation only to the advection
nodes by using a relaxation multiplier less than one. Apply this to the advection nodes. This will direct
the under relaxation only to those nodes that need to be under relaxed and still give some flexibility, by
allowing the solution module to search for an optimum relaxation parameter.
Main Index
Chapter 7: Thermal/Hydraulic Theory 213
Network Methods
QTRAN Microfunctions
Microfunctions are a unique QTRAN feature. Frequently, there is a need to apply very complicated
temperature or heat sources that may consist of tabular data, sines or cosines, exponentials, constants, or
terms which may or may not be multiplied together or divided by one another. QTRAN lets each discrete
component of a complicated temperature or heat source be defined as a “microfunction”. Once all of
these component microfunctions have been defined, then a library is available from which to build the
more complicated functions (macrofunctions) that are needed for temperature or heat sources. Many
macrofunctions are allowed to reference the same microfunction. Thus, for a very complicated tabular
data microfunction, it is only necessary to build it once and then reference it as many times as needed.
Other microfunctions can then be used to multiply or scale this complicated microfunction. Currently,
the argument of a microfunction can be either time, temperature, a temperature difference, a temperature
average, or a σ * (T[1] 4 - T[2] 4) radiation potential. If the radiation potential is specified, QTRAN will
convert the T[1] and T[2] values to degrees absolute before computing the radiation potential value.
QTRAN Macrofunctions
As stated above, a macrofunction consists of one or more microfunctions that are either multiplied or
divided by one another. Quite complicated macrofunctions can be expressed in this manner. Note that,
when building temperature or heat sources, it is quite allowable to assign more than one macrofunction
to the same node. Multiple macrofunctions assigned to the same node are simply added together to
compute the final source value.
Flow Networks
This section briefly outlines the fundamentals of fluid flow networks and the associated equations.
Main Index
214 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Methods
2
P I – P J = ΔP = ρ f L V
-------------------------- (7-18)
2D
2ρ
m· = A fL . PI - PJ (7-20)
D
2ρ
1
m· = A fL . ------------------------ ( P I - P J ) (7-21)
PI - PJ
D
or:
m· = flow resistance * ( P I - P J )
2ρ |
Flow resistance = A fL . ------------------------------- (7-22)
----- + K | PI - PJ |
D
Adding gravity and pump/turbine heads, the basic equation in matrix form can be written as:
[ K p ] [ P ] = [ m· ] + [ Heads ] (7-23)
Main Index
Chapter 7: Thermal/Hydraulic Theory 215
Network Methods
The flow resistance is a function of pressure; therefore, the problem is nonlinear and an iterative
procedure is required for solution. The resistances are computed, assembled and the matrix equations are
solved for nodal pressures.
Main Index
216 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Numerical Analysis Techniques
If the heat absorbed into the capacitor is treated as merely another heat flow, the left hand side of this
equation can be moved to the right side and presented as:
0 = SUM [ i = 1, all ] { Q [ i, T [ i, ( t + β *dt ) ] ] } (7-25)
where the value of T[t+β*dt] is taken as:
T [ i, ( t + β * dt ) ] = T [ i, t ] * ( 1 – β ) + T [ i, ( t + dt ) ] * β (7-26)
Furthermore, since t and T[i,(t)] may be assumed known and hence constant, using the corrector equation
to integrate with respect to time may be seen to be equivalent to finding a value of T[i,(t+dt)] that zeros
the following function:
0 = SUM [ i = 1, all ] { Q [ i, T [ t + β *dt ] ] } (7-27)
Main Index
Chapter 7: Thermal/Hydraulic Theory 217
Numerical Analysis Techniques
T[i] the temperature at node “i” being integrated with respect to time
t current time at which T[i] is known
dt current integration time step
b Hughes integration algorithm explicit/implicit weighting factor
SUM[i=1,all] { Q[i,T] } total heat flow rate into node “i” from all other resistors and/or
heat sources. Flow into the node is based on the temperatures at
time = t + β * dt for resistor heat flows and temperature-
dependent heat sources. Time-dependent heat sources are based
simply on time = t + dt
C[i] ρ * V * Cp, where ρ is the density of the capacitor’s materials,
V is the volume associated with the capacitor, and Cp is the
capacitor’s specific heat. C[i] is evaluated at a temperature of
T[i,(t+β*dt)]
ΣC
dt s table = ------- (7-28)
-
ΣG
dt
R = ----------------- (7-29)
-
dt stable
if
( R ≤ 0.35 )β = 0
else
β = 3R –1
----------------
6R
β = MAX ( β, 0.0 )
(7-30)
QTRAN currently offers this basic scheme as an optional adaptive weighting algorithm. A significant
feature of QTRAN’s adaptive explicit/implicit weighting scheme is a lower cut-off value for the Fourier
Modulus. If the Fourier Modulus is such that the current time step being used by QTRAN is less than
0.35 of the stable time step for a given node, that node is then integrated with β = 0.0 (totally explicit).
This can speed up calculations very significantly.
Main Index
218 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Numerical Analysis Techniques
SNPSOR Algorithm
QTRAN uses a Strongly Nonlinear Point Successive Over Relaxation (SNPSOR) equation solving
algorithm which is a diagonalized hybrid of Newton’s First Order Method and Newton’s Second Order
Method when solving the systems of equations generated by a thermal network. Many nonlinear
computer programs use a linear point iterative technique such as Gauss-Seidel coupled with successive
over relaxation (SOR). Such an algorithm will frequently prove to be satisfactory. However, this
algorithm can run into difficulties if the equation system is strongly nonlinear as is the case with “hot”
thermal radiation problems where temperatures of 2000+ C may be encountered. When linear SOR
algorithms encounter these problems, under relaxation is usually used to force convergence. However,
this under relaxation will usually cause convergence to be unacceptably slow and will frequently
adversely affect accuracy due to premature convergence.
An approach to the problem is to use a hybrid of Newton’s First Order Method and Newton’s Second
Order Method. Newton’s First Order Method is essentially the same as using the first two terms of a
Taylor series to estimate a function's zero, while Newton’s Second Order Method uses the first three
terms to estimate the zero. Unfortunately, Newton’s Second Order Method requires three function
evaluations per iteration if it is to be used. Furthermore, the Second Order Method is generally
prohibitively costly and wasteful on conduction problems since conductive heat transfer is generally very
close to being linear (First Order). It should also be noted that conduction dominated nodes are generally
the most numerous in large thermal system networks. The approach used by QTRAN is a hybrid of the
First Order and Second Order methods. Specifically, second derivatives are not calculated for conduction
terms (i.e., conductive resistors are assumed to be linear within a given iteration and their contribution to
the node’s First derivative is simply the sum of the resistor’s reciprocal values (conductances)). All other
heat contributions to a node (e.g., capacitances, convective resistors, radiative resistors, mass flow
resistors, and heat sources are assumed to be nonlinear and hence Second derivatives are calculated for
these terms). Conductive resistor heat flows (which are generally the most numerous) are therefore
calculated only once per iteration while other heat flows are calculated three times per iteration. The
result is a rapid yet solidly convergent algorithm capable of both rapid computation for conduction
problems and reliable convergence for the strongly nonlinear problems. For more information
concerning Newton’s Second Order Method, see Ref. 3. in Appendix A.
While the hybrid Newton’s method works great for most problems, there are a few classes of problems
that present pathological cases for failing any Newton’s method. These are the classic “S” shaped curves,
and phase transition problems introduce exactly this type of “S” shape into the nodal heat flow rate curve.
Fortunately, QTRAN can detect a phase transition and will shift to a bisection method for any node
currently undergoing a phase transition. Bisection methods are relatively slow, but they are immune to
the “S” shaped curves.
Main Index
Chapter 7: Thermal/Hydraulic Theory 219
Numerical Analysis Techniques
schemes can speed the solution of elliptic problems by a factor of over 30 for many problems which are
commonly encountered. Numerical experiments by the author with QTRAN’s adaptive relaxation
algorithm (i.e., QTRAN estimates and continuously updates the relaxation parameter for the adaptive
algorithm) have shown that the adaptive algorithm is over twice as fast as the optimal fixed over-
relaxation algorithm for many transient problems. QTRAN’s adaptive relaxation algorithm has also
proven to be quite successful in estimating the optimal relaxation parameter for steady- state problems.
Special note should be made that over-relaxation (not under relaxation) can be used even with the “hot”
thermal radiation problems. QTRAN’s SNPSOR algorithm does not (in general) force the user to resort
to under-relaxation to gain a sufficient radius of convergence (with the possible exception of a few
sublinear problems), whereas codes relying on linear SOR solvers frequently do.
QTRAN’s relaxation parameter estimation algorithm is based on the convergence rate R of the iterative
solution, where R is calculated from:
E[i]
R = ------------------- (7-31)
-
E[i – 1]
where:
E[i-1] is the largest iterative delta (positive or negative) at the i-1'th iteration, and E[i] is the largest
iterative delta (positive or negative) at the i'th iteration. In the limit as the iteration count i goes to infinity,
the following formula (see eq. 3-83, 3-113, and 3-116 of Ref. 10. in Appendix A) may be used to
estimate the relaxation parameter (assuming that the eigenvalues of the iteration matrix based on the
current relaxation parameter have not yet become complex).
( R + RELAX current – 1 )
A = ------------------------------------------------------------
- (7-32)
RELAX current
B = A ×A (7-33)
--------------
R
if
( B ≤ 1.0 ) then
RELAX new = RELAX current
else
C = square root ( 1.0 – B )
2.0
D = RELAX damp ------------------ – RELAX current
1.0 + C
RELAX new = MIN ( RELAX new, RELAX maximum )
endif
RELAXmaximum is the maximum allowed relaxation parameter which can be set by the user. The
theoretical maximum value is 2.0 and the code limits it to a value of 1.999. RELAXdamp is a damper on
the rate of increase of the relaxation parameter. As with other applications of numerical analysis, this
parameter does not have a theoretical basis, but numerical license allows for its interjection. This
parameter tends to prevent the over-relaxation parameter from going beyond its optimum value.
Main Index
220 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Numerical Analysis Techniques
As stated previously, this algorithm works fairly well as long as i approaches infinity and the eigenvalues
of the iteration matrix have not become complex. However, i never approaches infinity in practice and
eigenvalues frequently become complex.
QTRAN approaches the i going to infinity problem by recognizing that what one is really after is to
simply get a “good” estimate of the convergence rate R in some averaged sense. Specifically, R will
frequently change values drastically in early iterations for a given time step or for a steady-state problem,
and also after the relaxation parameter has been updated. What one wants to do is simply wait for the R
value to stabilize before updating the estimate of R. This can be easily done by simply requiring that, for
a finite number of iterations (say (3) iterations): (1) R be less than 1.0, (2) that the sign of the iterative
delta’s are constant, and (3) that the value of RELAXcurrent has not been updated more recently than (4)
iterations ago. If these three conditions are met, you can assume that the value of R[i] is approaching the
asymptotic limit of R[infinity].
One minor complication to all of this is that the above algorithm for calculating RELAXnew is valid only
as long as the eigenvalues of the iteration matrix do not become complex (this was alluded to earlier).
For more information, see Ref. 9. in Appendix A. This brings up two major problems: (1) how does one
know when the eigenvalues have gone complex, and (2) what to do then, since there is no theory for
predicting the optimal relaxation parameter for a system with complex eigenvalues. The answer lies in
purely empirical numerical engineering.
First, one observable fact is that the largest iterative delta’s E[i] have a tendency to oscillate in sign (+
and -) once the eigenvalues have gone complex (they can change sign at other times too, but the E[i] will
frequently oscillate continuously with complex eigenvalues). Second, the cause of complex eigenvalues
is usually that the value of RELAXcurrent is greater than RELAXoptimum for the equation system being
solved (although you have no way of knowing how much greater). However, since an oscillating sign is
an indication that RELAXcurrent is too large, QTRAN simply subtracts 0.01 from the value of
RELAXcurrent each time that the sign of E[i-1]/E[i] changes. Eventually, the value of RELAXcurrent is
reduced back to near RELAXoptimum. It is also worth knowing that from a practical consideration,
RELAXcurrent needs only to be within about 0.002 of RELAXoptimum in order to be “exact”.
Finally, the value of RELAXcurrent is limited so that 0.01 <= RELAXcurrent <= 1.999.
if
Main Index
Chapter 7: Thermal/Hydraulic Theory 221
Numerical Analysis Techniques
else
keep iteratin
end if
This basic formula can be derived from the equations presented in Convergence Acceleration Schemes,
218 along with a formula used to compute the sum of an infinite series.
Energy balance is often used as a convergence criteria but it is not used as a criteria in QTRAN even
though it is printed out.
The energy balance in the QTRAN output is equal to the energy stored during a time step for transient
problems and is zero for steady-state problems. If advection is present, then the energy balance will
include the net energy carried into and out of the problem by the flowing fluid. When examining the
energy balance for the system, it should be compared to the total energy flow in the system. If the system
energy balance was 1100 when a zero was expected, it would be a large number; however, if it were
compared to the total system energy which may be 1.1 x 1012, then the 1100 for the system energy
balance becomes a small number.
Q SB = Q NF – Q S
where, QNF is the combined net heat flows on all nodes including the boundary nodes and QS is the heat
fluxes by applied Heating or macro functions. In cases where the heat flow is driven by boundary nodes,
the system energy balance is simply the sum of all net heat flow rates on every node (including the
boundary nodes) as reported in QOUT.DAT. The system energy balance may be higher than the control
volume heat balance (heat entering the system minus heat leaving the system) since it also reflects the
numerical tolerances on the calculated nodes. As such, it provides a more realistic picture of the
uncertainty.
Linear Interpolation
This is the simplest table algorithm used by QTRAN and involves simple linear interpolation between
table data points. Linear extrapolation is used when data is requested that lies outside of the X-Y data
provided by the user.
Main Index
222 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Numerical Analysis Techniques
Main Index
Chapter 7: Thermal/Hydraulic Theory 223
Numerical Analysis Techniques
Note: A restriction to the phase change algorithm is that no capacitor is allowed to undergo more
than one phase transition per time step.
Main Index
224 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Numerical Analysis Techniques
Main Index
Chapter 8: Thermal/Hydraulic Input Deck
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
J Overview 226
J QTRAN Input Data File (QINDAT) 227
J
QTRAN Run Control Parameters and Node Number Declarations
229
J Material Properties 263
J Network Construction 276
J Boundary Conditions 322
Main Index
226 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
Overview
This chapter is divided into five major sections which contain all of the information necessary for
assembling the QTRAN input data file QINDAT. The functions of the five sections are detailed as
follows:
• Overview--Input Data File
• Run Control Parameters and Node Number Declarations
• Material Properties and Phase Change Sets
• Thermal Resistors and Capacitors
• Boundary Conditions
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 227
QTRAN Input Data File (QINDAT)
Main Index
228 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Input Data File (QINDAT)
This command would cause QTRAN to read in NR127.NRF as a restart file. The next NRnnnNRF file
that QTRAN generates will be named NR200.NRF. QTRAN reads the time and temperatures from the
NRnnnNRF file. The time overrides TSTART and the temperatures override any TEMP data. If a TIME
has been defined on the restart card, it overrides all other times and is used for TSTART to continue the
run.
Note: The RESTART capability only works with binary nodal result files. If the NRFORM flag
has been set to 1 so as to generate ASCII nodal result files, the Patran utility, READER,
must be used to convert the ASCII file to the binary equivalent prior to restarting QTRAN.
Defining the over write flag OVRWFL with something greater than zero will cause any temperatures
specified in the TEMPDAT file to over write those specified in the restart file. This allows the user to
change either initial of fixed temperatures from those specified by the restart conditions. The temperature
over write is performed before the user restart function URSTRT is called. URSTRT is always the final
restart operation.
$INSERT filename
Inserts the file cp10 into the input data file stream at this point. Nesting of $INSERT commands is
permitted. The depth of file nesting is currently limited to ten deep. This command must begin in column
one of any line in the input data file and there must be exactly one space between $INSERT and the file
name.
$ECHO_ON or $ECHO_OFF
Enables or disables, respectively, the printing of input data file information into the output data file at the
point where the $ECHO_ON or $ECHO_OFF command is encountered. These commands must begin in
column 1 of any line in the input data file.
$STATUS
Sends the remainder of the input data file line to the status file. This can be used to keep track of QTRAN
when large data files have been prepared, or to debug input data files.
$TRACE_ON or $TRACE_OFF
Commands QTRAN to send each line of the input data file to the status file as it is read. This is used
primarily for debugging purposes.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 229
QTRAN Run Control Parameters and Node Number Declarations
Title Data
The title data are alphanumeric character strings (80 characters total) that are used as a text description
(title) for the QTRAN output file. QTRAN will continue to read the input file and will continue to treat
the data as title data until it encounters a dollar sign ($) in column 1.
Remember that if the character string begins with an asterisk (*) or semicolon (;) in column 1, QTRAN
will treat the line as a comment line and will not include the line in the title data. This is consistent with
the QTRAN convention of using an asterisk in column 1 to denote an input data file comment line.
Examples
IECHO Y
IECHO N
Main Index
230 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IECHO A parameter that specifies whether or not the input data is to be echoed into the
output file. The convention is as follows:
N-- No Echo
Y-- Echo
Notice: This option may be overridden by using the $ECHYO_ON or $ECHO_OFF
commands. If the $ECHO commands are used, they must begin in column 1 of the
input data file. There is no limit to the number of these $ECHO commands that may
be used, and they may be used on any line of the input data file. These commands
are especially useful for selectively suppressing the echo of the QINDAT file into
the QOUTDAT.
Examples
ISCALE K
ICCALC R
TLABEL SECONDS
Two temperature scales must be specified: one that will be used to present the output file data (ISCALE)
and one that will be used for calculations (ICCALC). The temperature scales for ISCALE and ICCALC
may be identical. In addition, a 10 character label for the simulation time units must be specified. This
label (TLABEL) will be printed out with the results of all steady-state or transient runs. It is not used for
anything else, and may be left blank.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 231
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
ISCALE Alphabetic entry that corresponds to the output temperature scale to be used.
Regardless of the temperature scale being used to perform the calculations, the
temperatures may be output in Celsius, Fahrenheit, Kelvin, or Rankine by entering
the appropriate character for ISCALE. The convention is as follows:
C-- Celsius
F-- Fahrenheit
K-- Kelvin
R-- Rankine
ICCALC Alphabetic entry that corresponds to the temperature scale to be used to perform
all calculations (e.g., evaluation of temperature-dependent properties, evaluation
of temperature dependent heat source/sink functions). The same temperature scale
codes that are shown above for ISCALE are used for ICCALC.
Regardless of the scale specified for ICCALC, thermal radiation problems will
automatically use correct absolute temperature scales when evaluating heat flows
across thermal radiation resistors. Specifically, if ICCALC is specified as C,
QTRAN will use K when evaluating the potentials of 6 * T4 at each end of the
thermal radiation resistor and will use R if ICCALC was specified as F. Resistor
material properties will still be evaluated using the scale specified by ICCALC.
TLABEL A 10 character entry that corresponds to the time units that are being used for the
simulation (e.g., seconds, minutes, hours, fortnights, etc.). TLABEL is not used for
any internal units conversions or anything else except that the 10 characters will
be printed out after TIME values with the output data. TLABEL may be left blank.
codeindent10
HIOPT 0 2 1
or
HIOPT 1 2 10
or
HIOPT 2 2 4
Main Index
232 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
HIOPT Run-option parameter selects one of the following three options:
All hydraulic solutions are quasi steady-state. If a transient run is being made,
whenever the hydraulic solution is executed it will be a steady-state solution with
the thermal conditions at the beginning of the hydraulic solution being used for the
flow network evaluation.
HSOL Parameter that selects a solution option default SOL is 2 (Direct solver option).
Currently, the only direct solution option SOL=2 is supported.
NTBHUP Usage is dependent on the thermal option selected. If a steady-state thermal solution
is being executed, then the hydraulic network solution is recomputed every
NTBHUP thermal iterations. For a transient thermal solution, the hydraulic solution
is updated every NTBHUP time steps. The hydraulic solution is highly nonlinear
and can require significant computer resources. By computing mass flow rates
(hydraulic network solution) less often, the overall solution is speeded up without
any significant loss of accuracy as long as the flow properties (viscosity, density,
etc.) are not a strong function of temperature.
There is a strong coupling between the hydraulic and thermal solutions if buoyancy
is included in the hydraulic solution. In this case the two solutions should be updated
every iteration by setting NTBHUP to 1.
codeindent10
IOPT 5 0 0
or
IOPT 3 1 10
or
IOPT 3 2 1 8
or
IOPT 2 0 5
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 233
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IOPT Run-option parameter that selects one of the following six calculation sequences
(see Section 5.2.6 for an explanation of TSTART and TSTOP):
A data check only. Input data will be read and echoed, but no calculations will be
performed.
A transient run after initial-steady state calculations have been performed. All time
dependent functions are calculated for the initial steady-state calculation using
time = TSTART.
A transient run from initial conditions, followed by a steady-state run from the final
conditions. Time-dependent functions will be evaluated using time = TSTOP.
A steady-state run with the time-dependent functions for the steady-state run
evaluated at time = TSTART, followed by a transient run, followed by a final steady-
state run with the time-dependent functions evaluated at time = TSTOP.
SOL Parameter that chooses a thermal solution option.
Standard SNPSOR solution algorithm, default.
Main Index
234 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
NITBUP The Number of Iterations Between Updates. What is updated is dependent on the
solution option. If the standard solution is used (SOL = 0), then all nodes that may
have been eliminated from the solution because they satisfied the second transient
convergence criteria (EPSIT2) are included in the solution every NITBUP iteration.
All nodes are evaluated after the solution has converged to guarantee that they are
within the desired convergence tolerance. A value between IMIN / 2 and IMIN is
recommended. The default value is 1000. This value has no effect for a standard
solution, steady- state case. For the modified solution (SOL = 1), NITBUP is the
frequency that the conductive resistors are update for both the steady-state and
transient solutions. The best value for NITBUP is, of course, problem dependent.
For many transient problems, it is sufficient to update the conductive resistors only
once per time step, to specify a NITBUP value greater than the value of IMAX
(IMAX is the maximum number of iterations allowed per time step). Note that no
matter what value is given to NITBUP, QTRAN will automatically recompute the
conductive resistor values at the beginning of each time step. For steady-state
problems, experimentation with your specific problem is the rule of the day. Values
of NITBUP between 10 and 100 are usually appropriate. The default NITBUP value
is 0 (update every iteration). If the direct solver is used (SOL = 2), the NITBUP
determines how many standard solutions (SNPSOR algorithm) are executed before
another direct solution is performed. If material properties and boundary conditions
are constant or are weak functions of temperature, the direct solution should be able
to calculate the exact answer in one or with very few iterations. In these cases, the
NITBUP value should be one. If there are strong nonlinearities involved, such as
high temperature radiation boundary conditions, then it is best to do several
SNPSOR solutions before doing another direct solution. This gives very sensitive
parts of the problem a chance to relax using a much faster solution method while still
using a direct solution to carry along the stiff portions of the problem that require
many SNPSOR type iterations. For the highly nonlinear case, NITBUP values
between 5 and 10 are appropriate.
MFLIPF The maximum number of over all solutions flip flops by the maximum temperature
error before a bisection of all nodes is performed. The error must be less than three
orders of magnitude of the allowable error about zero before it is considered a
flip/flop condition. (Default value is 8.)
IMIN(keyword) IMIN
IMAXSS(keyword) IMAXSS IMAXHS
ISSDMP(keyword) ISSDMP
Examples
IMAX 36
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 235
QTRAN Run Control Parameters and Node Number Declarations
IMIN 9
IMAXSS 2000 500
ISSDMP 2000
Note: IMAX and IMIN values have an effect on both the accuracy and the run time of a transient
solution. If IMAX and IMIN are very small, QTRAN will take generally smaller time steps
than if IMAX and IMIN were large. The smaller time steps increase accuracy for problems
involving hard transients at the expense of larger CPU times. Large values of IMAX and
IMIN (e.g., “large” might be 100 and 50 for IMAX and IMIN, respectively) will generally
result in smaller CPU time requirements, but certain details of hard transients may be
blurred. If the problem involves only mild transients with no step function heat or
temperature sources, larger values of IMAX and IMIN can usually be used with little
danger. If the problem involves a very hard transient problem with many detailed
perturbation events that are desired to be captured, use IMAX and IMIN values near the
defaults of 30 and 8, respectively. The default values of 20 and 8 are considered “safe” or
conservative values, while values of 100 and 50 (or larger) are considered more aggressive.
Also, the IMAX value should be larger than IMIN by enough to permit convergence on the
first iterations after the time step is increased. This is to prevent increasing the time step,
but then decreasing it the next time step because the new time increment did not converge
in IMAX iterations.
Main Index
236 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IMAX Maximum number of iterations allowed for any given time step during transient
runs. If the number of iterations exceeds IMAX without converging, the time step is
decreased and convergence is attempted again. This will be repeated until
convergence occurs with less than or equal to IMAX iterations. If zero is entered,
QTRAN will supply a default value of 36.
IMIN Minimum desired number of iterations required to achieve convergence on any
given time step for transient runs. If the number of iterations does not equal or
exceed IMIN iterations before convergence, the time step size is increased for the
next integration step. If zero is entered for IMIN, QTRAN will supply a default
value of 9. IMIN should be less than or equal to IMAX.
IMAXSS Maximum number of iterations allowed for steady state calculations. If QTRAN
does not achieve convergence within IMAXSS iterations, a message which states
that convergence failed will be printed along with the current values of temperatures
and heat fluxes. The program then terminates. If a zero is entered for IMAXSS,
QTRAN will supply a default value of 2000.
IMAXHS Maximum number of iterations allowed for the steady state hydraulic calculations.
ISSDMP Number of steady-state iterations between print dumps. When a steady-state run is
underway, QTRAN will print the results every ISSDMP iterations until the problem
has converged. If zero is entered for ISSDMP, QTRAN will supply a default value
of 2000.
Control Parameters
DT(keyword) DT DTMIN
TSTART(keyword) TSTART
TSTOP(keyword) TSTOP
TSFMIN(keyword) TSFMIN
TSFMAX(keyword) TSFMAX
HYEPIS(keyword) HYEPIS HYHDEP HYMDEP HYPREP
EPSISS(keyword) EPSISS
EPSIT(keyword) EPSIT EPSIT2
PERTUR(keyword) PERTUR
RELAXS(keyword) RELAXS IFSRLX
RLXSAT(keyword) RLXSAM RLXSAD RLXSAU
RLXSRT(keyword) RLXSRM RLXSRD RLXSRU
RLXSHT(keyword) RLXSHM RLXSHD RLXSHU
RLXSCT(keyword) RLXSCM RLXSCD RLXSCU
RLXSST(keyword) RLXSSM RLXSSD RLXSSU
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 237
QTRAN Run Control Parameters and Node Number Declarations
Main Index
238 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Examples
DT 1.0D-04
TSTART 0.0D+00
TSTOP 1.0D+02
TSFMIN 0.6D+00
TSFMAX 2.0D+00
HYEPIS 1.0D-04 1.0D-04 1.0D-04 1.0D-04
EPSISS 1.0D-03
EPSIT 1.0D-04 1.0D-07
PERTUR 5.0D-02
RELAXS 1.0D+00 1
RLXSAT 1.99 0.80 1.0
RLXSRT 1.99 0.92 1.0
RLXSHT 1.999 0.94 1.0
RLXSCT 1.999 0.95 1.0
RLXSST 1.999 0.95 1.0
RELAXT 1.0D+00 1
RLXTAT 1.99 0.80 1.0
RLXTRT 1.99 0.92 1.0
RLXTHT 1.999 0.94 1.0
RLXTCT 1.999 0.95 1.0
RLXTST 1.999 0.95 1.0
BETA 1.0D+00 0.0 1.0
DELMAX 1.0D+03 -1.0D+30 1.0D+30
PCBAND 1.0D+00 1000.0
GRAVTY 9.81 0.0 0.0 9.81
SBC 0.0D+00
DCMF 1
This section allows the initial time step (DT) to be defined, starting time (TSTART), stopping time
(TSTOP), time step multipliers (TSFMIN and TSFMAX), steady-state and transient convergence rate
criteria (EPSISS, EPSIT, and EPSIT2), the perturbation parameter used for Newton’s Second-Order
Method (PERTUR), the relaxation parameters used for accelerating iteration convergence (RELAXS and
RELAXT), the explicit/implicit ratio control variable (BETA), the maximum allowed temperature
change per iteration (DELMAX), the phase change temperature band over which phase change energies
are smeared (PCBAND), the specific heat curve integration step size (CPDELT), the Stefan-Boltzmann
thermal radiation constant (SBC), and the Discontinuous Macrofunction Flag (DCMF).
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 239
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
DT Initial time step used for transient calculations. DT will usually be adjusted during the
course of a transient run by QTRAN to take advantage of easily followed transients or
to ensure accuracy during more difficult transients. If 0.0 is entered for DT, QTRAN will
set DT to a nonzero but very small number (e.g., 1.0E-30). This is not recommended, but
one should not be afraid to start with small time steps to give QTRAN the opportunity
to follow a strong transient. For example, if the initial value of DT was set to 1.0D-4, it
would take 16 calculation intervals to grow to 1.0 if the growth factor on the time step
was 1.8 and the transient was mild enough to enable a time step of 1.0 units. If the initial
value of DT was 1.0D-5 or 1.0D-6, it would only take 20 or 24 calculation intervals
respectively to reach a DT value of 1.0.
The time step, DT, must be greater than 1.0E-10 * TSTOP. If a problem requires a time
step smaller than this, it is probably best broken into multiple parts with restarts and
corresponding adjustments to the IMIN and IMAX parameters to fit the regions of the
problem that require the small and large time steps.
DTMIN The minimum allowed time step to be used for any calculation interval. Default is 1.0E-
30. This value should be changed only as a last resort to get a difficult problem to run or
when the user wants to force fixed time points regardless of errors that may be
introduced because of lags in response to a given boundary condition.
TSTART Starting time used for transient runs. It is also used to evaluate time-dependent functions
if initial steady-state calculations are being performed.
TSTOP Stop time for the program run. It is also used to evaluate time-dependent functions if a
steady-state run is being performed after a transient run.
TSFMIN Time step multiplier that is used to decrease the time step size in case convergence has
failed after more than IMAX (see Section 5.2.5) number of iterations. TSFMIN should
normally be between 0.0 and 1.0. A recommended value is TSFMIN = 0.6. To run with
a constant time step, simply set TSFMIN and TSFMAX (see following TSFMAX
definition) to 1.0.
Main Index
240 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
TSFMAX Time step multiplier that is used to increase the time step size in case convergence has
occurred in less than IMIN (see Section 5.2.5) number of iterations. TSFMAX will not
increase the time step size to a value greater than DTMAX (see Section 5.2.8.1).
TSFMAX should normally have a value greater than 1.0. A suggested value is TSFMAX
= 1.8, but a larger value may be used to allow a rapid increase in the time step, or use a
smaller value to limit the perturbation to the system when time steps are increased. To
run with a constant time step, simply set both TSFMIN (see previous TSFMIN
definition) and TSFMAX to 1.0. The IMIN, IMAX, TSFMIN, and TFSMAX parameters
all work together. Care should be taken so not to get into the condition that the DT
increment is increased too much so that it will be decreased in the next time step. The
product of TSFMIN and TSFMAX should be greater than one so that the problem will
experience some increase in time step even if the time step is cut down in the next
calculation increment.
HYEPIS Convergence criteria used by flow network solver. Static pressure, head differential
across an element (pressure + gravity head + buoyancy head, etc.) and mass flow rates
have to converge within HYEPIS before the flow solution is declared converged.
HYEPIS is an absolute value and is used for all three parameters being checked. Care
should be exercised in selecting this value to be sure that unit and the range of values are
properly represented. The mass flow rate typically will be a much smaller value than the
pressure and selecting a value consistent with the pressure will have no direct effect on
the mass flow rate convergence criteria; however, if the convergence criteria was
selected to operate on the mass flow rate, it would probably be too restrictive to enable
convergence of the differential head.
HYHDEP Convergence criteria used by the flow network solver as an independent check on the
head differential across an element.
HYMDEP Convergence criteria used by the flow network solver as an independent check on the
mass flow rate at each hydraulic node.
HYPREP Convergence criteria used by the flow network solver as an independent check on the
pressure at each hydraulic node.
EPSISS Steady-state convergence criteria that is used by QTRAN. This value is the estimated
maximum error of the worst (least converged) node in the system, and is NOT an
iterative delta as used by many codes. For example, to converge to the nearest 0.001
degrees, enter 0.001 for EPSISS and QTRAN will iterate until its estimate of the error
of the worst node in the system is 0.001. Note that this convergence criteria is typically
10 to 100 times more severe than the criteria used in codes which rely on an iterating
delta. For example, a value of 0.001 for EPSISS is frequently equivalent to a CINDA
convergence criteria of at least 0.0001 to 0.00001. It should be especially noted that
while EPSISS is directly related to the system error, the iterative delta convergence
schemes (such as are used in CINDA) are truly only related to the convergence rate of a
particular problem and not to the problem error. It is best to conservatively run with
EPSISS = 0.0001 and obtain good results; however, with EPSISS = 0.1, reasonable
answers on many problems may be obtained.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 241
QTRAN Run Control Parameters and Node Number Declarations
EPSIT Transient convergence criteria that is used by QTRAN (see EPSISS above). A
recommended value is EPSIT = 0.0001. Experience seems to indicate that this is a very
good value for most problems. Larger values of EPSIT do not make transient problems
run as much faster as you might think, and smaller values seem to be overkill. The idea
seems to be that you need to converge a system of equations to within the truncation error
of the basic time integration scheme. Convergence beyond this truncation error is
probably an exercise in fooling yourself. Conversely, if the problem fails to converge to
within the truncation error of the integration scheme, the residual noise (error) in the
solution seems to hinder the predictor equation to the point where the poorer predicted
temperatures slow things down more than was gained by the looser convergence criteria.
EPSIT2 Optional modification to the transient convergence criteria. It can be thought of as a “cut-
out” convergence criteria that can be used to speed convergence. Specifically, for
transient problems, QTRAN will compare each nodes iterative error to EPSIT2. If that
node’s last iterative error was less than EPSIT2, that node is cut out of the iteration
sequence for the remainder of the time step. This allows QTRAN to iterate only on those
nodes that are still changing significantly. Please note that the EPSIT2 value should be
SIGNIFICANTLY smaller (at lease two or three orders of magnitude) than the EPSIT
value. Remember, a large number of very small changes can add up over a period of
time, so make sure that EPSIT2 is significantly smaller than EPSIT. The default value
for EPSIT2 is 0.0 (this gives the standard QTRAN SNPSOR algorithm).
PERTUR Perturbation parameter that is used to evaluate derivatives for Newton’s Second-Order
Method used by QTRAN. PERTUR corresponds directly to the traditional dx that is used
in classical central difference schemes to evaluate derivatives. In this case, PERTUR is
used to evaluate both 1st-Order and 2nd-Order derivatives. If the value of PERTUR is
grossly too large, the error in the evaluation of the derivatives may cause convergence to
be slow. Conversely, if the value of PERTUR is too small (especially for radiation
calculations), the perturbations caused by PERTUR may be so small that they are
swallowed by round-off error, causing the derivatives to be evaluated as zero and
subsequent nonconvergence. If this problem occurs, you should experiment with
different PERTUR values. A recommended PERTUR value is 0.01. Smaller values may
be used for mass flow and convection problems, while “hot” radiation problems of
several thousand degrees Kelvin may require values of 1.0 or greater. A value that is too
large or too small may also cause steady-state convergence to fail. In general, problems
that are fairly linear in the temperature variable (i.e., temperature-independent material
properties and convection correlations with no radiative nodes) are relatively insensitive
to larger values of the PERTUR parameter and will tolerate small PERTUR values.
Problems that are strongly nonlinear in the temperature variable (e.g., hot radiation
problems) are generally more sensitive to the size of the PERTUR variable and may not
tolerate extremely small PERTUR values due to the round-off phenomenon. Note that
despite all of the above warnings, PERTUR values of 0.1 to 0.01 rarely fail in practice.
Main Index
242 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
RELAXS Steady-state relaxation parameter. RELAXS is used only for steady-state calculations,
and its sole function is to speed convergence (i.e., to reduce the number of iterations
required for convergence to a certain accuracy). The absolute value of RELAXS should
be between, but not including, 0.0 and 2.0. Positive values invoke QTRAN’s adaptive
relaxation algorithm, whereas negative values of RELAXS inhibit the adaptive
algorithm. Normally, the value entered for RELAXS should be +1.0, thus allowing
QTRAN’s adaptive relaxation algorithm to function. Values with magnitudes greater
than 2.0 will cause the algorithm to diverge, while values with magnitudes less than 1.0
may increase the radius of convergence at the expense of the convergence rate. If the
adaptive algorithm is enabled, QTRAN begins iterations with your RELAXS value as
the initial guess of the relaxation parameter. It is better to guess low at this value because
QTRAN’s adaptive algorithm will converge more quickly to the optimal value from
below than from above. Furthermore, if the initial guess at the temperature distribution
is very poor (and this is typically the case), a value of RELAXS = +1.0 will allow
QTRAN to smooth the system slightly before using over relaxation.
This smoothing is sometimes necessary for strongly nonlinear systems in order to
achieve convergence. The total amount of work required for a steady-state solution is
extremely dependent on this parameter. It is not unusual for an optimally over-relaxed
problem to run in 1/30th the time of a nonreligious (RELAXS = -1.0) problem.
QTRAN’s adaptive algorithm takes the guesswork out of what this value should be.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 243
QTRAN Run Control Parameters and Node Number Declarations
IFSRLX A flag that indicates how the relaxation parameters are to be applied to the system of
equations being solved. Three options are available. If the IFSRLX=0 option is used,
then the relaxation parameter applies to all nodes in the system equally. All nodes are
searched each time step, the maximum error is determined, and the relaxation and
convergence factors are determined based on the maximum error of the system
regardless as to what type of boundary condition is applied to the node. The IFSRLX=1
option applies relaxation and convergence factors based on the type of node and
boundary condition that is present at the node. A hierarchy is established as to the type
of boundary condition present at the node. This order is from advection, radiation,
convection down to conduction. If any node has advection applied, then the advection
relaxation parameters will apply even if there is also radiation and or convection at the
same node. Advection can destroy the diagonal dominance of the matrix and as such it
may be desirable to set the relaxation parameters to force under relaxation for these
nodes so that the circle of converge of the problem can be increased. Similarly, the
radiation nodes will probably be the most likely to exhibit large fluctuations, therefore,
it is not desirable for the relaxation parameters to increase as rapidly for these nodes as
for the nodes that exhibit straight conduction. This option, which allows for these
groupings, is the recommended option. The third option, IFSRLX=2, is to have the
relaxation parameters calculated on a node-by-node basis. This option will usually give
the tightest converged solution. The convergence factor is also calculated individually
for each node and a node that may not have the largest error could be changing slower
than the node that had the greatest error. Thus, the convergence factor could be much
larger. The system error is the product of the iteration error and the convergence factor.
As a result, the system error determined on a node-by-node basis could be greater than
that determined for the system or group methods. The error criteria can probably be
relaxed, if the node-by-node relaxation option is used compared to the group or system
option.
RLXSAM Maximum steady-state relaxation parameter that is to be used with all advection nodes.
Values input must be greater than 1.0 and less than 2.0
Notice: The relaxation variables discussed below and their association to the input file,
Keyword, is shown in the Control Parameters, 236.
RLXSAD Advection steady-state relaxation damping factor. Based on several conditions, the
relaxation parameters are recalculated. The new relaxation parameters are compared to
the old values and the actual amount of change is reduced according to the damping
multiplier. For example, suppose that the new relaxation factor was calculated to be
1.860 and the old one was 1.0. If the damping factor was 0.95, then the actual relaxation
factor defined at this calculation step would be 1.817. In the early stages of a solution,
the iterative delta is probably the largest. This may be the time that it is not desirable to
over relax, particularly with advection. By using small damping factors, the degree of
over relaxation is reduced but will be allowed to approach its optimum value as the
solution continues and is usually when the solution is better behaved. In problems where
advection is causing convergence problems, it may be desirable to reduce this parameter
to 0.05.
Main Index
244 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
RLXSAU Steady-state multiplier used with all advection nodes. All multipliers are applied by type
of node and boundary conditions regardless of the application option that is specified.
This parameter is used to implement under relaxation. The relaxation parameter will
always be calculated between the values of 1.0 and 2.0, but when they are applied to the
iterative delta, the RLXSAU multiplier is included. Thus, if the relaxation parameter was
1.8 and the multiplier 0.3, the effective relaxation parameter would be 0.54 or an under
relaxed state. Under-relaxation or multipliers less than 1.0 should only be used in those
cases where the node-by-node application of the relaxations parameters has failed to
yield convergence. Note that the relaxation parameters specified in the output or status
file reflect the multipliers and are only applied to the actual temperature change.
RLXSRM Maximum steady-state radiation relaxation value allowed.
RLXSRD Steady-state radiation relaxation damping factor.
RLXSRU Steady-state radiation relaxation factor multiplier.
RLXSHM Maximum steady-state convection relaxation value allowed.
RLXSHD Steady-state convection relaxation damping factor.
RLXSHU Steady-state convection relaxation factor multiplier.
RLXSCM Maximum steady-state conduction relaxation value allowed.
RLXSCD Steady-state conduction relaxation damping factor.
RLXSCU Steady-state conduction relaxation factor multiplier.
RLXSSM Maximum steady-state system relaxation value allowed.
RLXSSD Steady-state system relaxation damping factor.
RLXSSU Steady-state system relaxation factor multiplier.
RELAXT Transient solution relaxation parameter which is similar to the previous RELAXS
parameter. RELAXT is used only for transient calculations. QTRAN’s adaptive
relaxation algorithm may be selected in the same manner as RELAXS, and for transient
calculations may easily half the solution time when compared to a fixed relaxation
scheme. Whenever the time step changes in magnitude, or after a direct solution, the
relaxation parameter is reset to 1.0. All the associated relaxation parameters that were
discussed for the steady-state case can be applied independently to the transient part of
the solution. These parameters are listed below.
IFTRLX A flag that indicates how the relaxation parameters are to be applied to the system of
equations being solved. Three options are available. If the IFTRLX=0 option is used,
then the relaxation parameter applies to all nodes in the system equally. The IFTRLX=1
option applies relaxation and convergence factors based on the type of node and
boundary condition that is present at the node. The third option, IFTRLX=2, is to have
the relaxation parameters calculated on a node-by-node basis.
RLXTAM Maximum transient relaxation parameter that is to be used with all advection nodes.
RLXTAD Advection transient relaxation damping factor.
RLXTAU Transient multiplier used with all advection nodes.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 245
QTRAN Run Control Parameters and Node Number Declarations
Main Index
246 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
DELMAX Maximum allowed temperature change per iteration. If an iterative temperature change
is calculated with a larger magnitude than DELMAX, the sign is kept but the magnitude
is limited to DELMAX. If 0.0 is entered for DELMAX, a default value of DELMAX =
1000.0 will be used. DELMAX is used as a last-ditch effort to help force convergence to
occur for the extremely rare problems for which QTRAN’s SNPSOR algorithm may
otherwise fail. Normally, use the default value for DELMAX of 1000.0 by entering a 0.0
for DELMAX.
MINTMP Minimum allowed temperature of a problem. In some cases, especially after strong
perturbation in boundary conditions, explicit calculations or initial prediction can
extrapolate the solution to unreasonable values. By specifying minimum and maximum
values for the solution, any node whose value is extended beyond the limits of the
solution will be declared to be solved by fully implicit means and the new guess in node
temperature will be MINTMP. Care must be exercised that the value of MINTMP is not
within the limits that can be expected for normal numerical oscillation of the solution.
MAXTMP Maximum allowed temperature of a solution.
PCBAND Temperature interval over which phase changes will be smeared. If set to 0.0 or less, a
value of 1.0 degrees will be used. The smaller the value of PCBAND that is used, the
more accurate the answer will be at the expense of more computation. Phase change
begins at the phase change temperature minus PCBAND and is completed at the phase
change temperature plus PCBAND. Phase change begins at the phase change
temperature minus PCBAND and is completed at the phase change temperature plus the
PCBAND.
CPDELT Temperature integration step size used to evaluate an integrated average of the specific
heat across a time step. If the specific heat is highly variable (e.g., a spike or other
discontinuity exists in the Cp vs. temperature curve), set CPDELT to a fraction of the
width of the spike. The calculated temperature change during a time step is divided by
CPDELT to determine the number of points that the specific heat is to be evaluated. The
specific heat is the average of all evaluations at each temperature point determined by
CPDELT and is evaluated independently for each node, at each iteration for each time
step. If CPDELT is greater than the temperature change, two points - the beginning and
resultant temperature - will be used each time step to determine the specific heat. This is
the default if CPDELT is left blank.
GRAVTY Gravitational constant used with turbine, pump head calculation and for required internal
units conversions. The default value is dependent on the ICCALC option. If Metric or an
English temperature is specified, 9.80665 meters / second / second or 32.1741 feet /
second /second respectively is used.
GX Positive value indicates that gravity is working against a positive x direction. Default is
0.0.
GY Positive value indicates that gravity is working against a positive y direction. Default is
0.0.
GZ Positive value indicates that gravity is working against a positive z direction. Default is
0.0.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 247
QTRAN Run Control Parameters and Node Number Declarations
SBC Stefan-Boltzmann thermal radiation constant. If SBC is entered as zero, QTRAN will set
SBC to 5.6696D-08 W / (m2-K4) if ICCALC is in degrees K or C, and to 0.1712D-
08 Btu/(hr-ft2-R4) if ICCALC is in degrees R or F.
DCMF Discontinuous Macrofunction Flag. If set to 0, there is no effect. If set to 1, DCMF alerts
QTRAN’s transient integration algorithm that one or more macrofunctions may be
severely discontinuous in nature. QTRAN then uses a β value of 1.0 for nodes with
macrofunctions assigned to them. Using β = 1.0 allows the transient integration
algorithm to notice sharp discontinuities in dT/dt that occur in the middle or end of a time
step and then forces QTRAN to use smaller time steps in the neighborhood of such a
discontinuity.
Example
IRQFLO 1 1 1 1 1 1 1 1 1
Main Index
248 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IRQFLO Allows print/no print options to be selected for resistor, capacitor, and heat source
macrofunction data in the system. Setting IRQFLO(i) to 1 causes QTRAN to print
data for the i'th entry in the following list, while any other value causes no data to
be printed for that item. The data is printed at the end of a steady state run, or at each
print interval for a transient run. This data includes such things as resistor heat flow,
conductance, capacitance, material property data, and others. The list of IDMNRF(i)
items is as follows:
IRQFLO(6) -- Capacitors
Since there can be a large amount of data (especially conductive and radiative
resistor data), you normally should be selective about the volume of information that
is requested.
Example
NRFORM 0
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 249
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
NRFORM Format of the nodal results file.
The flag that tells QTRAN whether to output the nodal results file is ASCII or
binary. NRFORM=0 will give a binary file (default). NRFORM=1 will generate a
text file.
Example
IDMNRF 1 0 0 0 0 0 0 0 1 1 0 0 1 0 1 1 1 1
Main Index
250 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IDMNRF Allows which items are to be put in the nodal results files. The first eight items plus
fifteenth through the nineteenth into the nodal results files with the prefix
designation NRnnn, ninth and tenth go to NPnnn type files, and the eleventh through
the fourteenth go into NHnnn type files. The list of IDMNRF(i) items is as follows:
IDMNRF(1)--Temperatures
IDMNRF(7)--Temperature error
IDMNRF(16)--Convective Heat Flux - Note that the heat flux summary for plotting
is only associated with the application region. The area is unknown or may not exist
for the coupled node.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 251
QTRAN Run Control Parameters and Node Number Declarations
IDMNRF(19)--Surface Recession
Main Index
252 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Flag that determines what record gets put in the nodal results file. IDNMRF=0
implies that the record will not go to the nrf file while IDMNRF=1 implies that the
record will be put out in the nodal results file. If all items are flagged, the following
columns would represent the data in the different nodal results files:
NRnnn Column 1 Temperature
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 253
QTRAN Run Control Parameters and Node Number Declarations
Example
DTMAX 1.0D+01 100.0
This example sets the maximum allowed time step to 10.0 for the thermal solution and 100.0 seconds for
the hydraulic solution.
Parameter Description
DTMAX Initial maximum value of the time step allowable for transient calculations, regardless of
the number of iterations given for the IMIN parameter (see Iteration Limit Parameters,
234). The time step used for integration will not exceed the value of DTMAX that is set.
However, the value of DTMAX can be adjusted (see Maximum Allowable Time Step
Adjustments, 253) during a transient run.
DTMAXH Initial maximum value of the time step allowable for hydraulic calculations. The
maximum time allowed to lapse before the hydraulic solution is updated. This is used in
conjunction with the NTBHUP parameter to control when new hydraulic calculations are
performed. The time and counter are both indexed at the time a new hydraulic solution is
calculated with the next update determined by whichever parameter is tripped next.
Example
DTMAXA 7.0D+00 5 200
This sets the new DTMAX value to 7.0 at time = 5.0 for the thermal solution and while setting a new
DTMAXH value of 200 for the hydraulic solution.
QTRAN allows the value of the maximum allowable time step (DTMAX) to be adjusted at arbitrary
times in a transient simulation if desired. The values of DTMAXA(I,1), DTMAXA(I,2), and
DTMAXA(I,3) are entered as an ordered group, where DTMAXA(I,1), DTMAXA(I,2), and
DTMAXA(I,3) are defined as follows
Main Index
254 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
DTMAXA(I,1) I'th new value of DTMAX that you want to define.
DTMAXA(I,2) I'th time at which the value of DTMAX is to be reset to the new value specified
by DTMAXA(I,1). As many pairs of DTMAXA data as needed may be entered.
Values defined for DTMAXA groups will force QTRAN to end a time step and
to begin a new time step at the DTMAXA(I,2) values.
DTMAXA(I,3) I'th new value of DTMAXH that is to be defined.
When all DTMAXA data is entered, enter a dollar sign ($) in column 1 of the
input data file. After all of the DTMAXA data is entered, enter the dollar sign ($)
in column 1 and proceed to Node Definitions, 254.
Node Definitions
QTRAN requires that each node referenced in Network Construction, 276 and Boundary Conditions, 322
must be declared by assigning it a node number in this section. This section explains how to enter data
to declare node numbers for the thermal network. Node numbers need not be consecutive, but they must
be greater than zero. If a reference to a node is made in these two sections that was not declared, QTRAN
will print an error message in the output data file that identifies the undeclared node number and will then
terminate execution.
Node numbers are declared by entering a node number declaration block. Each block defines a starting
node number, an ending node number, and a node number increment within the block (exactly like a
FORTRAN do-loop). As many blocks may be entered as are needed to define the nodes. When no more
blocks are to be entered, simply enter a dollar sign ($) in column 1 of the input data file. The block
variables are defined as follows:
Two groups of node numbers are declared-hydraulic and thermal. The hydraulic nodes have all the same
properties and attributes of the thermal nodes, but have additional properties. Hydraulic nodes have
pressure, mass flow rate, and other properties associated with them that are necessary to calculate fluid
flow through a set of fluid elements that define various flow characteristics. As a result of the PATQ
translation (menu pick 2), those declarations are placed in the PNODEDAT file.
Note: All hydraulic nodes must be defined before the thermal nodes are defined. It is not
necessary that the node numbers be less than the thermal node number, but they must be
defined first in this section of the QTRAN input.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 255
QTRAN Run Control Parameters and Node Number Declarations
Example
DEFPND 10 100 1
This example defines nodes 10 through 100 in increments of 1.
Parameter Description
DEFPND(1) Starting node number of the block.
DEFPND(2) Ending node number of the block. This value should be consistent with the value of
DEFPND(1) and DEFPND(3) (again, exactly like a FORTRAN do-loop) or it may not
be assigned. For example, if DEFPND(1)=1, DEFPND(2)=4, and DEFPND(3)=2, the
assigned node numbers will be 1 and 3. While this is probably not what the user would
have intended, this will be the result. A correct set of values, for example, might be
DEFPND(1)=20, DEFPND(2)=30, and DEFPND(3)=2. This would declare node
numbers 20, 22, 24, 26, 28, and 30.
To declare single nodes, simply use the same value of DEFPND(2) that is used for
DEFPND(1) (the single node number being declared) with a value of 0, 1, or blank for
DEFPND(3). Alternatively, using the default options for DEFPND(2) and
DEFPND(3), simply enter the node number being declared for DEFPND(1) and leave
DEFPND(2) and DEFPND(3) as blank or zero.
Node number declarations are a user convenience. They allow modification of a given
network by adding or subtracting nodes at will without having to completely renumber
all of the nodes in the model. They also allow node numbers to be assigned to different
regions of the model for clarity (e.g., nodes 100-199 to region 1, nodes 200-299 to
region 2, nodes 1000-9999 to radiosity nodes, etc.), or any other scheme that may be
conceived.
As a result of the PATQ translation (menu pick 2), these declarations are placed in the NODEDAT file or
the VFNODEDAT file for VIEW FACTOR nodes (menu pick 3).
Example
DEFNOD 110 410 2
This example defines nodes 110 through 410 in increments of 2.
Main Index
256 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Note: Although node numbers may be entered in any order and “holes” may be left in the node
number scheme, very large problems will have a CPU time penalty for this during the
initialization phase only (not during the analysis phase). For very large problems it is
cheaper to have the nodes numbered 1 through N sequentially. The reason for this is that
every node number that is declared here is reassigned an internal node number reference by
QTRAN. This is done for storage efficiency as well as CPU efficiency. Every reference to
one of the node numbers by a resistor, heat source, etc., involves a “look up” operation by
QTRAN (during the initialization phase only) to see what the internal node number is for
the node number referenced by the resistor, heat source, etc. This “look up” operation first
checks to see if, by chance, the internal node number is the same as the nodal number. If it
is, no search is necessary. If it is not, QTRAN has to look through the list of node number
references until it finds the nodal number. If thousands of nodes are involved, this can take
some time (but again, this is done only during the initialization phase and NOT during the
calculations).
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 257
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
DEFNOD(1) Starting node number of the block.
DEFNOD(2) Ending node number of the block. This value should be consistent with the value of
DEFNOD(1) and DEFNOD(3) (again, exactly like a FORTRAN do-loop) or it may
not be assigned. For example, if DEFNOD(1)=1, DEFNOD(2)=4, and
DEFNOD(3)=2, the assigned node numbers will be 1 and 3. While this is probably
not what the user would have intended, this will be the result. A correct set of values,
for example, might be DEFNOD(1)=20, DEFNOD(2)=30, and DEFNOD(3)=2. This
would declare node numbers 20, 22, 24, 26, 28, and 30.
To declare single nodes, simply use the same value of DEFNOD(2) that you use for
DEFNOD(1) (the single node number being declared) with a value of 0, 1, or blank
for DEFNOD(3). Alternatively, using the default options for DEFNOD(2) and
DEFNOD(3), simply enter the node number being declared for DEFNOD(1) and
leave DEFNOD(2) and DEFNOD(3) as blank or zero. Node number declarations are
a user convenience. They allow modification of a given network by adding or
subtracting nodes at will without having to completely renumber all of the nodes in
the model. They also allow node numbers to be assigned to different regions of the
model for clarity (e.g., nodes 100-199 to region 1, nodes 200-299 to region 2, nodes
1000-9999 to radiosity nodes, etc.), or any other scheme that may be conceived.
Temperature coupling is a means of equivalencing boundary, regions or independent nodes without them
having to be congruent and still retain their original identity. This can be used to perform cyclic
redundancy calculations, couple surfaces together which have different material properties where
different mesh densities are desired or couple different types of networks together. For example an
axisymmetric region can be coupled to a three dimensional region without making any geometric
assumption regarding the transition between the regions. The only assumption is that the temperatures
would be the same.
For example, where it was desired to have a transition between the axisymmetric and three-dimensional
regions, the region where the circumferential temperature gradient vanished would be the coupling
region. If regions between different materials were coupled the surface with the lowest conductivity
would be the application node and the high conductivity region would be the coupled or node the
application node would be coupled to. Here the assumption would be that the high conductivity material
would dominate the temperature gradient along the common interface.
Main Index
258 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Internally what happens is all capacitors and resistor that have a temperature coupling node are replaced
by the coupling node. If a resistor has the same node ID for both identifiers it is removed from the
calculation sequence. At each output request the temperature coupling application node temperature is
replaced by the temperature coupling node’s temperature, thus the model retains its original geometric
characteristics for all post processing.
Example
TCOUPL 110 410
In this example all internal references to node 110 are replaced with node 410 and all temperature output
for 110 will be assigned the temperature value of node 410.
Parameter Description
TCPLND Temperature coupled node. The node that will be replaced in the solution by the
temperature coupling node.
TCPLCN Temperature coupling node. This is the node that the coupled temperature will be
equivalenced to for solution purposes. This node’s temperature will be assigned to
the coupled node for output purposes.
As a result of the PATQ translation (menu pick 2) these declarations are placed in the NODXYZDAT
file.
Example
NODXYZ 1 1.01122D+0 3.33121D-1 2.22222D+1
This example shows that node 1 has an x, y, z coordinate of 1.01122, 0.333121, and 22.2222 respectively.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 259
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
NODEID User node ID that the x, y, z node locations are to be applied. The node locations are
stored internally in the same order that the node temperatures are defined. Thus all
internal node index references are consistent with the node locations defined in this
block. It is not necessary to input all node locations, only those that are to be used in
the analysis. When no more data is to be entered in the node locations block, simply
put a dollar sign ($) in column 1.
NODEX Node x location in a global Cartesian coordinate system.
NODEY Node y location in a global Cartesian coordinate system.
NODEZ Node z location in a global Cartesian coordinate system.
Print Control
This section explains how to enter print interval data. Below describes how to enter an initial output print
interval; Print Interval Adjustments, 259 describes how to enter data to alter this value during the course
of a transient run; and Nodal Print Block Definitions, 260 describes how to specify which nodal
temperatures will be printed as output data.
Example
TPRINT 1.0D+01
This example sets the print interval to 1.0D+01 seconds.
Parameter Description
TPRINT Initial time interval between successive output data printings for transient
calculations. The print-time interval may be modified (see Print Interval
Adjustments, 259) during a transient run.
Example
PRINTA 10.0 5.0
PRINTA 100.0 1000.0
PRINTA -4.0 1501.0
This will cause a new print interval of 10.0 at time = 5.0 and another new print interval of 100.0 at time
= 1000.0. Print dumps will also be made at 5.0 and 1000.0. The negative print interval at time 1501 will
force the output times to be on even multiples of the print increment. The 1501 print staging will yield
Main Index
260 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
printout at 1500 second which is a result of the normal print increment of 100 at the previous staged time,
plus a print dump at time 1501 which is forced at all print staging times, plus a print out at time 1504
because the print was forced to be on even multiples of the print increment. All further print dumps will
be at multiples of 4.0 time units.
QTRAN allows the value of the output print interval to be adjusted during the course of the simulation.
The values of PRINTA(I,1) and PRINTA(I,2) are entered as an ordered pair. PRINTA(I,1) and
PRINTA(I,2) are defined below.
Parameter Description
PRINTA(I,1) New print interval value for output during a transient simulation. Negative values
force the output to be on multiples of the print interval.
PRINTA(I,2) Time at which the new print interval will be initiated, and the time at which a print
dump will be made.
As many pairs of PRINTA data may be entered as needed. Data entered for PRINTA
pairs will force QTRAN to end a time step and to begin a new time step on any time
values entered for PRINTA(I,2). When all PRINTA data pairs have been entered,
enter a dollar sign ($) in column 1 of the input data file and proceed to Nodal Print
Block Definitions, 260. If no PRINTA data is needed, enter a dollar sign ($) in column
1 and proceed to Nodal Print Block Definitions, 260.
Example
PBLOCK 2 20 2 ; (Print even nodes 2 - 20 in the QOUTDAT file)
This will cause the even node numbers from 2 to 20 to be printed out. The comment to the right of the
semicolon will be ignored by QTRAN.
Note: This command has no effect on the nodal results files generated directly by QTRAN.
PBLOCK(1), PBLOCK(2), and PBLOCK(3) allow the starting node number to be specified, the ending
node number, and the node number increment, respectively, of a Print Block (group of nodes whose
temperature values are to be printed).
QTRAN will continue to read data for Print Blocks until a dollar sign ($) is encountered in column 1 of
the input data file. If no entries are made in this section, QTRAN will print temperatures for all nodes in
the system. As many Print Block definitions may be entered in the QINDAT file.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 261
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
PBLOCK(1) Used to specify the first node number of a Print Block. For example, to print node
numbers 15-23 for the nodal Print Block, PBLOCK(1) should have the value of 15.
PBLOCK(2) Used to specify the last node number of the Print Block. For example, to print node
numbers 15-23 for the Print Block, the value of PBLOCK(2) should be 23.
To specify single nodes as a Print Block, enter the same value for PBLOCK(2) as
was entered for PBLOCK(1), or you may enter both PBLOCK(2) and PBLOCK(3)
as zero or blank.
Example
IPLTBK 2 20 2 ; (Write even nodes 2 - 20 to the QPLOTDAT file)
This will cause results data for the even node numbers from 2 to 20 to be written to the QPLOTDAT file.
The comment to the right of the semicolon will be ignored by QTRAN.
IPLTBK(1), IPLTBK(2), and IPLTBK(3) allow the starting node number to be specified, the ending
node number, and the node number increment, respectively, of a Plot Block (group of nodes whose
temperature values are to be written to the plot file).
QTRAN will continue to read data for Plot Blocks until a dollar sign ($) is encountered in column 1 of
the input data file. If no entries are made in this section, QTRAN will open or create a plot file. As many
Plot Block definitions may be entered in the QINDAT file.
Main Index
262 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Run Control Parameters and Node Number Declarations
Parameter Description
IPLTBK(1) Used to specify the first node number of a Plot Block. For example, plot node
numbers 15-23 for the nodal Plot Block, IPLTBK(1) should have the value of 15.
IPLTBK(2) Used to specify the last node number of the Plot Block. For example, to plot node
numbers 15-23 for the Plot Block, the value of IPLTBK(2) should be 23.
IPLTBK(3) DEFAULT: If a 0 or blank is entered for IPLTBK(2) and IPLTBK(3), QTRAN will
set IPLTBK(2) to the value entered for IPLTBK(1) and will set IPLTBK(3) to 1.
Used to specify the node number increment for the Plot block. For example, plot all
node numbers from 15-23, the value of IPLTBK(3) should be 1. Negative values of
IPLTBK(3) are allowed and may be used if needed.
To specify single nodes as a Plot Block, enter the same value for IPLTBK(2) as was
entered for IPLTBK(1), or enter both IPLTBK(2) and IPLTBK(3) as zero or blank.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 263
Material Properties
Material Properties
This section is used to define material properties to QTRAN, including properties which are to be
assigned after phase changes have occurred.
Use the procedure shown below to define a material property.
1. Enter all data for the material property from MPID Number, Function Type, Temperature Scale,
Factor and Label, 263. This information specifies the material property identification (MPID)
number, defines the function type that will be used to evaluate the material property, the
temperature scale conversions necessary (if tabular or power series evaluations are to be
performed), a scaling factor, and text line labels that will be used to document the material
property in the printout.
2. Enter all Material Property Data, 268. This section is used to enter x-y table data,
coefficient/exponent data for a power series evaluation, data for use in a Sutherland equation,
values for constant material properties, or phase change data sets. When all data has been entered,
enter a slash (/) in column 1 of the next input data file line and continue on to Step (3).
3. If no more material properties are to be entered, enter a dollar sign ($) in column 1 of the next
input data file line and proceed on to Network Construction, 276. If more material properties are
to be defined, return to Step (1) and continue with this procedure until all material property data
has been entered for this section.
Note: This data is normally extracted from the MPIDMKSBIN, MPIDIPSBIN, MPIDFPHBIN or
MPIDCGS material property databases via PATQ menu pick 4 or placed in the MATDAT
file by the user.
Example
MPID 1234 T Fahrenheit 2.0D+00
Zinc Oxide Thermal Conductivity
This declares that material property ID number 1234 will be a linear table input in degrees Fahrenheit
(only the first character of ITSCAL is significant) and that the material property values in the table will
be scaled by a factor of 2.0D+00. The material property label is “Zinc Oxide Thermal Conductivity.”
When the MPID, IEVAL, ITSCAL, FACTOR, and LABEL data have been entered, proceed to Material
Property Data, 268 to finish defining the material property.
Main Index
264 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
Parameter Description
MPID Material Property Identification Number (MPID) that is assigned to each material
property. This MPID number will then be used to reference the material property in
Network Construction, 276 as part of the thermal resistor and capacitor data. MPID
numbers must be greater than 0 when defined in this section.
IEVAL Material property evaluation code that denotes whether the material property is to
be evaluated as a constant, table, power series, Sutherland equation, Bingham
equation, reciprocal relation, straight line, arbitrary order polynomial, phase change
data set, or user-supplied subroutine. The allowed evaluations are listed below. Note
that only the first character of the IEVAL string is typically significant, so T, Table,
and Table_Data are equivalent. There are exceptions. For example the power series
evaluation and the phase change data sets. For these two characters must be supplied
(i.e., PO for power series or PH for phase change data sets). If the IEVAL character
string contains blanks, it must be enclosed in single quotes. The MDATA1 and
MDATA2 values are input constants that are specified in Material Property Data,
268.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 265
Material Properties
B - This property is the viscosity of fresh water at normal pressures, and the viscosity
is to be calculated using the Bingham equation (see Ref. 4, p. 665). The units will be
N-s/m2 if the calculations are performed in Celsius or Kelvin, and lbm/ft-s if the
calculations are performed in Fahrenheit or Rankine.
Main Index
266 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
PE - The data forms are indexed tabular functions which is linear interpolated. the
independent variable is normalized by the period which is the difference between
the maximum and minimum values specified for the independent variable.
PH - The data will be evaluated as a phase change data set, with each
MDATA1/MDATA2 data pair corresponding to a phase transition temperature
(MDATA1), and a latent heat (MDATA2).
MDATA2(1)
P(T) = MDATA1(1) * T + ...
MDATA2(N)
+ MDATA1(N) * T
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 267
Material Properties
1
P ( T ) = ------------------------------------------------------------------------------------------------
( MDATA1 ( 1 ) * ( T + MDATA2 ( 1 ) ) )
where:
Notice: The scale factor for this evaluation option is read but not used.
ITSCAL Temperature scale for which the tabular input data is valid (all other conversion
routines ignore ITSCAL). QTRAN will automatically convert data tables from other
temperature scales into the temperature scale defined for calculations (see ICCALC,
(p. 230)). For example, if calculations are being performed in Kelvin (i.e.,
ICCALC = K in Temperature Scale and Time Units Definition, 230 but the material
property data available is in Celsius, QTRAN will convert this table to Kelvin before
use if ITSCAL is entered as C. Note that only the first character of the ITSCAL
character string is significant, so “F” and “Fahrenheit” are equivalent.
Main Index
268 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
Table data may be converted to or from any of the following temperature scales:
F--Fahrenheit
C--Celsius
K--Kelvin
R--Rankine
T--Time
If T (for time) is given for ITSCAL, no table conversions will occur. The “material
property” is then evaluated as a time dependent function, regardless of the IEVAL
option selected.
FACTOR A scaling factor that is used to easily scale a material property’s values. The value
entered for FACTOR is used to multiply the property data. If a number whose
absolute value is less than 1.E-18 is entered for FACTOR, FACTOR will be
assigned a value of 1.0. In addition to scaling for parameterization runs, FACTOR
may also be used to change units systems conveniently.
Notice: FACTOR applies to all material property evaluation options EXCEPT the
BINGHAM fresh water viscosity equation and the user-supplied subroutine option.
For these options, FACTOR is read but is not used.
LABEL One or more 80-character identification labels that will be read by the program and
printed with the echoed input data. These labels identify material properties for your
convenience, but the labels are not used by QTRAN. These labels allow short
messages to be printed (e.g., NITROGEN VISCOSITY) with the material property
data to facilitate documentation. As many lines of label data as desired may be
entered (anything between the MPID line and the terminating / character that does
not start with the keyword MDATA will be treated as a label).
MDATA1 and MDATA2 are material property data pairs and are entered for the various evaluation
algorithms.
Example
MDATA 2.0 5.0
This defines an MDATA1 value of 2.0 and an MDATA2 value of 5.0. Depending upon the evaluation
option selected (IEVAL parameter), the 2.0 and 5.0 may be used in various ways. See below for more
specific information.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 269
Material Properties
ARBITRARY-ORDER POLYNOMIAL
Enter the polynomial coefficients into the MDATA1 array. MDATA2 data will be ignored. The
MDATA1 data will be used in the following fashion for the polynomial:
P(T) = MDATA1(1) + MDATA1(2) * T + MDATA1(3) *
2 (N-1)
T + ... + MDATA1(N) * T
Example
MPID 17 Arbitrary-Polynomial Celsius 1.0
Example Arbitrary Order Polynomial Definition
MDATA 1.0
MDATA 1.3
MDATA -0.3
/
This example defines the polynomial
for MPID 17 with a scale factor of 1.0. It declares that the polynomial is valid in degrees Celsius. The
value of T used will be in degrees Celsius.
BINGHAM
Do not enter any parameters for a Bingham equation evaluation. The correct Bingham equation
parameters are already stored in QTRAN.
Example
MPID 23 Bingham Kelvin 1.0
Bingham Fresh Water Viscosity Equation
/
This example defines MPID 23 to be the Bingham freshwater viscosity equation.
CONSTANT
Enter the constant’s value as MDATA1(1).
Example
MPID 47 Constant Kelvin 1.0
Constant Material Property Definition
MDATA 1.2345
/
This material property definition defines MPID 47 to be a constant with a value of 1.2345. The scale
factor is 1.0, and the temperature scale definition of Kelvin is ignored.
Main Index
270 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
Example
MPID 3 Table Fahrenheit 1.0
Example Linear Table Property Definition
MDATA0.027.0
MDATA100.029.4
MDATA173.055.2
MDATA2000.087.3
/
This material property definition has temperatures of 0.0, 100.0, 173.0, and 2000.0 Fahrenheit and
property values of 27.0, 29.4, 55.2, and 87.3. It declares that it is a linear irregular interval table property
with a scale factor of 1.0 and an MPID number of 3.
codeindent10
MPID 4 Hermite Fahrenheit 23.79E-03
Example Linear Table Property Definition
MDATA0.027.0
MDATA100.029.4
MDATA173.055.2
/
This material property definition has temperatures of 0.0, 100.0, and 173.0 Fahrenheit and property
values of 27.0, 29.4, and 55.2. It declares that it is a Hermite Polynomial irregular interval table property
with a scale factor of 23.79E-03 and an MPID number of 4.
Note: At least two data pairs must be entered for the T option, and at least three data pairs for the
H option.
Example
MPID 3 ITable Fahrenheit 1.0
Example Linear Table Property Definition
MDATA0.027.0
MDATA100.029.4
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 271
Material Properties
MDATA173.055.2
MDATA2000.087.3
/
This material property definition has temperatures of 0.0, 100.0, 173.0, and 2000.0 Fahrenheit and
property values of 27.0, 29.4, 55.2, and 87.3. It declares that it is an indexed linear irregular interval table
property with a scale factor of 1.0 and an MPID number of 3.
Example
MPID 4 IHermite Fahrenheit 23.79E-03
Example Linear Table Property Definition
MDATA0.027.0
MDATA100.029.4
MDATA173.055.2
MDATA2000.087.3
/
This material property definition has temperatures of 0.0, 100.0, 173.0, and 2000.0 Fahrenheit and
property values of 27.0, 29.4, 55.2, and 87.3. It declares that it is an index Hermite Polynomial irregular
interval table property with a scale factor of 23.79E-03 and an MPID number of 4.
Note: At least two data pairs must be entered for the IT option and at least three data pairs for the
IH option.
Example
MPID 7 LCI K 1.0
Example LCI table property.
MDATA0.0 ; Base Temperature
MDATA100.0;Temperature Increment
MDATA23.7;Property Value at 0.0 K
MDATA 29.9;Property Value at 100.0 K
MDATA 25.3;Property Value at 200.0 K
MDATA17.2;Property Value at 300.0 K
MDATA0.7;Property Value at 400.0 K
MDATA0.7;Property Value at 500.0 K
/
Main Index
272 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
This material property definition declares that MPID 7 is an LCI equal interval linear table with a base
temperature of 0.0 K and a temperature increment of 100.0 K. The property values given are 23.7, 29.9,
25.3, 17.2, 0.7, and 0.7 with a scale factor of 1.0.
Please note that according to QTRAN convention, anything to the right of a semicolon (;) is an optional
comment and hence is ignored.
STRAIGHT LINE
The straight line will evaluate the MDATA1 and MDATA2 values that you enter exactly as follows:
P(T) = MDATA1(1) * T + MDATA2(1)
Example
MPID 32 M K 1.0
Example Straight Line Material Property
MDATA 0.17 117.9
/
This material property definition declares that MPID 9 is a straight line of the form:
P(T) = 0.17 * T + 117.9
with T valid for degrees Kelvin and with a scale factor of 1.0. The evaluation option (IEVAL) was given
as a character string surrounded by single quote marks, 'M (Straight Line)'. Only the first character, M,
is significant.
PEriodic Data
This option provides a mean of defining a repeating waveform which is linearly interpolated between
data points. The minimum and maximum independent variable values which defines an interval used to
normalize the input independent variable value so that interpolation is always between the minimum and
maximum value specified.
MDATA1 (1...N) = Independent variable values
MDATA2(1...N) = Corresponding property values
Example
MPID 104621 PEriodic Time 1.4
MDATA60.0122.
MDATA71.0212.
MDATA76.51400.
MDATA92.0220.
/
In the above example, the property will repeat every 32 time units following a linear interpolation. Note
by the example discontinuities are allowed between the beginning and ending of a period.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 273
Material Properties
Examples
MPID 1023 PHase Change Data Kelvin 1.0
Example #1 Phase Change Data Set
MDATA600.01024.9; T=600,H=1024.9
/
MPID 1 PH Rankine 1.1
Example #2 Phase Change Data Set
MDATA763.941.97E+06;T1=763.94,H1=1.97E+06
MDATA948.72.0E+05; T2=948.7, H2=2.00E+0541
/
POWER SERIES
The power series will evaluate the MDATA1 and MDATA2 values that are entered exactly as follows:
Example
MPID 49 Power Series Rankine 1.0
Example Power Series Material Property Definition
MDATA1.2-0.4
MDATA7.30.1
MDATA1.0E+012.0
/
This example material property definition declares that MPID 49 is a power series function of the form:
(-0.4) 0.1 2.0
P(T) = 1.2 * T + 7.3 * T + 1.0E+01 * T
RECIPROCAL FUNCTION
The Reciprocal function will evaluate the MDATA1 and MDATA2 values that are entered exactly as
follows:
1
P ( T ) = -------------------------------------------------------------------------------------------
MDATA1 ( 1 ) * ( T + MDATA2 ( 1 ) )
Example
MPID 10 'Reciprocal Function' Celsius 1.0
Main Index
274 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Material Properties
1
P ( T ) = -----------------------------------------------
1.0 * ( T + 273.15 )
with T valid for degrees Celsius and with a scale factor of 1.0. The evaluation option (IEVAL) was given
as a character string surrounded by single quote marks, 'Reciprocal Function'. Only the first character, R,
is significant. A common use of this type of material property is to define bulk coefficients of expansion
for ideal gases (1/T absolute).
SUTHERLAND
Enter the Sutherland equation data as follows:
MDATA1(1) P(0)
MDATA2(1) T(0)
MDATA1(2) S
where:
1.5
P(T) = T T(0) + S
------------ ----------------- + ---------------------
P(0) T(0)
1.5 T+S
Example
MPID 78 Sutherland Kelvin 1.1
Example Sutherland Equation Material Property
MDATA0.78.9;P[o] and T[o].
MDATA23.9; S.
/
This example material property definition declares that a Sutherland equation of the form:
1.5
(T )
( T ) = ----------------- ( 8.9 + 23.9 )
-------- - * ------------------------------
0.7 ( 8.9 1.5 ) ( T + 23.9 )
where T is valid for degrees Kelvin. Note that anything right of the semicolons in the example is an
optional comment and may be omitted.
USER-SUPPLIED SUBROUTINE
The user-supplied subroutine option will use both MDATA1 and MDATA2. The MDATA data pairs will
be passed to the user-supplied subroutine and may be used there as an option identifier, or for any other
purpose that the user wishes.
Example
MPID 88 U K 1.0
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 275
Material Properties
When all of the material properties have been defined, enter a dollar sign ($) in column 1 of the input data
file and proceed to Network Construction, 276.
Main Index
276 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Network Construction
This section describes how to define the thermal network to QTRAN. All resistors and capacitors will be
defined in this section. The parameters and options controlled by input are listed below.
1. Thermal Resistor Assignments.
2. Nodal Capacitance Data.
Note: PATQ normally generates all of the resistor and capacitor data automatically via menu pick
2.
To enter a data set for any given thermal resistor type, proceed to the appropriate section in any arbitrary
order, enter all required data for the resistor, and then proceed to the next resistor to be defined. When all
of the resistor information has been entered for the problem, place a dollar sign ($) in column one of the
input data file and proceed to Capacitor Data, 320.
This sections describes how to enter data that describe single conductive resistors. To define a conductive
resistor, follow the procedure outlined below.
Enter all data for the resistor from this section. This data defines the resistor as a conduction resistor,
defines the nodal connectivity of the resistor, defines the resistor as one-way or two-way (two-way is the
normal usage), identifies the material property to be used for thermal conductivity, and defines the
effective length/area data for the resistor.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 277
Network Construction
If no more thermal resistor data of any kind is to be entered, enter a dollar sign ($) in column 1 of the
input data file and proceed to Capacitor Data, 320. As a result for the PATQ translation (menu pick 2)
these declarations are placed in the CONDUCDAT file. If more thermal resistors are to be defined,
proceed to the appropriate section ((p. 276) to (p. 306)) and continue with resistor data input.
Example
C 4 7 23 1.4 23.7
This defines a conductive resistor between nodes 4 and 7 with a thermal conductivity MPID of 23, a
length of 1.4, and an area of 23.7.
Main Index
278 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
RES-TYPE An alpha character that defines the resistor type. In this case, RES-TYPE is
entered as C to identify a conductive resistor.
NODE1 Node 1 of the conductive resistor.
NODE2 Node 2 of the conductive resistor.
Notice: You may specify these resistors as one-way resistors if you wish. This
means that they may be made to transmit heat in one direction but not in the
other. If you wish to do this, input the node that you do not wish heat to flow to
as a negative number. Heat will then be allowed to flow from the negative node
to the positive node, but not from the positive node to the negative node.
MPID The MPID number of the material property that is to be used to calculate the
thermal conductivity of the resistor. See MPID Number, Function Type,
Temperature Scale, Factor and Label, 263. To define a time-dependent thermal
conductivity, enter MPID as the negative of the MPID to be used.
LENGTH Length of the conductive resistor.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 279
Network Construction
AREA Cross-sectional area associated with flux through the conductive resistor.
For Cartesian conductive resistors, the thermal resistance for such a resistor is
given by the following expression:
Length
R = ----------------------------
( k * Area )
where R is the resistor value, Length is the distance between nodes, k is the
thermal conductivity, and Area is the cross-sectional area available for heat to
flow through between the nodes. This expression may be factored and rewritten
in the following form, which separates the geometric data and the thermal
conductivity as follows:
For non-Cartesian resistors, you may enter the analogous values for Length
(LENGTH) and Area (AREA) that will result in the calculation of the
appropriate CSF for your non-Cartesian resistor. For example, the resistance of
a cylindrical wall is given by the expression:
R[2]
n ⎛ ------------⎞ * --------------------------------------
1
R: =
⎝ R [ 1 ]⎠ 2 * PI * L [ c ]
Main Index
280 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
where:
Thus, a correct and equivalent method to enter this resistor’s value is to let
AREA = 1.000
and to let
R[2]
n ⎛ ------------⎞ * --------------------------------------
1
Length: =
⎝ R [ 1 ]⎠ 2 * PI * L [ c ]
This yields a correct CSF value, which is the only information that is of
mathematical significance.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 281
Network Construction
This section allows a given thermal resistor to be identified as a convective resistor, to define its node
numbers, and to specify the resistor configuration.
Example
H 1 3 0 14
This heads the resistor data for a convective resistor between nodes 1 and 3 (no third node), and specifies
convection configuration number 14.
Parameter Description
RES-TYPE An alpha character that defines the resistor type. In this case, RES-TYPE is entered
as H to identify a convective resistor.
NODE1 Node 1 of the convective resistor.
NODE2 Node 2 of the convective resistor.
NODE3 Node 3 of the convective resistor. Although most convective resistors have only two
node numbers, certain of the convective resistors require that you define three
nodes. If the convective resistor that is being defined requires only two nodes, enter
a zero for the NODE3 value.
CFIG Convective resistor configuration identification number, where configuration is
defined as the class of convection correlations that would be used for a given
problem. For example, flat plates would be one type of resistor configuration, and
flow across horizontal cylinders would be another configuration type. For specifics,
consult the convective resistor catalogue in Convection Library (Ch. 9) for available
configurations. Allowed CFIG values are 1 to 37 inclusive, in addition to numbers
greater than or equal to 1000. CFIG values of 1000+ are used to refer to user-
supplied convection configuration subroutine.
Example
24.723.20.014.829.9
15.618.9
/
This enters 7 GP values of 24.7, 23.2, 0.0, 14.8, 29.9, 15.6, and 18.9, in that order using free format input.
Main Index
282 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
GP Convective resistor’s Geometric Properties such as length, diameter, surface area,
or gravitational constants. The exact meaning of each GP value varies for each
configuration. See Convective Resistor Header Data, 281. Consult Convection
Library (Ch. 9) for specific configurations and GP meanings. QTRAN will continue
reading GP values until it encounters a slash (/) in column 1 of the input data file.
The procedure for entering GP values is to enter all GP values followed by an input
data file line with a slash in column 1. It should be noted that any number GP values
may be placed on an 80 character line, or multiple lines may be used. The
maintaining of the order is the important consideration. Proceed on to Convective
Resistor Material Properties, 282.
Example
1 7 4 6 15 23
Parameter Description
MPID Material property identification numbers for the convective resistor. See MPID
Number, Function Type, Temperature Scale, Factor and Label, 263 for more
information. For specifics, consult the convective resistor catalogue in Chapter 6.
The material properties that correspond to each MPID entry are listed for each
configuration in the catalogue. When done entering MPID values, enter a slash (/)
in column 1 of the next line of the input data file.
Example
H 23 45 0 14
1.23 9.8 15
/
45 72 88 99 1024
/
This QTRAN input data defines a configuration 14 convective resistor between nodes 23 and 45. The GP
values are 1.23, 9.8, and 15. The MPID numbers are 45, 72, 88, 99 and 1024.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 283
Network Construction
This section describes how to identify a given thermal resistor as a black-body/gray-body radiative
resistor and to define the resistor node numbers. These resistors conduct heat according to the following
relation:
4 4
Q [ 1-->2 ] = σ * ( T [ 1 ] – T [ 2 ] )-
-----------------------------------------------------
R
where σ is the Stefan-Boltzmann constant, T[1] and T[2] are the temperatures of nodes 1 and 2 of the
resistor in degrees absolute (QTRAN will perform the conversion to degrees absolute no matter which
temperature scale is being used for calculations), and R is the value of the radiative resistor.
Example
R 1 3 4 2 15
This defines a gray radiative resistor between nodes 1 and 3 with the transmissivity evaluated at the
temperature of node 4, resistor subtype 2, and the transmissivity evaluated from MPID 15.
Main Index
284 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
RES-TYPE A character that defines the resistor type. In this case, RES-TYPE is entered as R to
identify a gray thermal radiation resistor.
NODE1 Node 1 of the radiative resistor.
NODE2 Node 2 of the radiative resistor.
NODE3 Node 3 of the radiative resistor (if applicable). If input as zero, it will be set to
NODE1. If a resistor subtype does not require a NODE3 value, enter a 0 for NODE3.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 285
Network Construction
This resistor type is used between a gray surface and a radiosity node, with an
emissivity that is taken from a material property (MPID).
1
Subtype: 2 R = ----------------------------------------------------------------
F [ i, j ] * A [ i ] * τ [ gas ]
This resistor type is used between radiosity nodes, and with a time or temperature
dependent participating media whose transmissivity is taken directly from a material
property (MPID).
1
Subtype: 3 R = ---------------------------------------------------------------------------------------
F [ i, gas ] * A [ i ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
The view factor is between the surface i and the gas (or other participating media
node). The transmissivity of the gas (or participating media) is taken from a material
property.
Subtype: 4 1
R = ------------------------------------
F [ i, j ] * A [ i ]
This resistor type may be used anywhere that material properties are constant. It
would normally be used as a view factor resistor between radiosity nodes, but the F
and A values are entered as simple constants and hence could be anything
appropriate for a radiative resistor of this formulation. Since there is no data for
transmissivity, the transmissivity of the resistor is implicitly assumed to be 1.0.
1
Subtype: 5 R = ---
F
This resistor type may be used anywhere that material properties are constant. It
would normally be used as a view factor resistor between two radiosity nodes, but
the F value is a simple constant and hence could be anything appropriate for a
radiative resistor of this formulation.
Note: This resistor type is used when a minimum of calculations are desired, thus
for this type only the reciprocal of the resistance is input.
1–e
Subtype: 6 R = ----------------
e * A
This resistor type may be used as a surface resistor, with the value given for e being
the emissivity. This resistor subtype may be used anywhere the emissivity is
constant. Because the emissivity is assumed to be constant, it is faster to evaluate
than Subtype 1.
1
Subtype: 7 R = ----------------------------------------------------------------
F [ i, j ] * A [ i ] * τ [ gas ]
Main Index
286 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
This resistor type is used between radiosity nodes. τ is calculated from an extinction
coefficient identified by the resistor’s MPID and from a view factor distance.
Specifically, τ[gas] = EXP(-S * P), where S is the view factor distance and P is the
extinction coefficient calculated from the material property (MPID) of the resistor.
1
Subtype: 8 R = ---------------------------------------------------------------------------------------
F [ i, gas ] * A [ i ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
τ is calculated from an extinction coefficient identified by the resistor’s MPID and
from a view factor distance. The transmissivity value τ is calculated in the same
manner as for Subtype 7.
Subtype: 9 1
R = -----------------------------------------------
AF [ i, j ] * τ [ gas ]
This resistor type is used between radiosity nodes, and with a temperature dependent
participating media whose transmissivity is taken directly from a material property
(MPID). This is the same as Subtype 2, except that F[i,j] and A[i] have been
combined as AF[i,j] for computational efficiency.
1
Subtype: 10 R = ----------------------------------------------------------------------
AF [ i, gas ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
The view factor is between the surface i and the gas (or other participating media
node). The transmissivity of the gas (or participating media) is taken from a material
property. This is the same as Subtype 3, except that F[i,j] and A[i] have been
combined as AF[i,j] for computational efficiency.
1
Subtype: 11 R = ----------------------------------------------
AF [ i, j ] * t [ gas ]
This resistor type is used between radiosity nodes. τ is calculated from an extinction
coefficient identified by the resistor's MPID and from a view factor distance.
Specifically, τ[gas] = EXP(-S * P), where S is the view factor distance and P is the
extinction coefficient calculated from the material property (MPID) of the resistor.
This is the same as Subtype 7, except that F[i,j] and A[i] have been combined as
AF[i,j] for computational efficiency.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 287
Network Construction
1
Subtype: 12 R = ----------------------------------------------------------------------
AF [ i, gas ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
τ is calculated from an extinction coefficient identified by the resistor’s MPID and
from a view factor distance. The transmissivity value τ is calculated in the same
manner as for Subtype 7. This is the same as Subtype 8, except that F[i,j] and A[i]
have been combined as AF[i,j] for computational efficiency.
AF = is the product of the surface's area and the view (subtypes 9-12) factor, and
This resistor type may be used between any nodes. The F[i,j] term is defined by a
material property (MPID) whose independent variable is either time or the
temperature of the i-th node in calculation units. This is normally used to define
dynamic viewfactor and thus would couple radiation between radiosity nodes.
However, if both surfaces have constant emissivities then the F term can be thought
of as a script F which includes any non black characteristics. The area term is a
constant for this evaluation. Since there is no data for transmissivity, the
transmissivity of the resistor is implicitly assumed to be 1.0. If diagnostic output is
requested the F[i,j] term is output as an emissivity value.
Subtype: 14 1
R = ---------------------
-
AF [ i, j ]
This resistor type may be between used any nodes. The AF[i,j] term is defined by a
material property (MPID) whose independent variable is either time or the
temperature of the i-th node in calculation units. This is normally used to define
dynamic viewfactor and thus would couple radiation between radiosity nodes.
However, if both surfaces have constant emissivities then the AF term becomes a
script F which includes any non black characteristics. The area term is a constant for
this evaluation. Since there is no data for transmissivity, the transmissivity of the
resistor is implicitly assumed to be 1.0. If diagnostic output is requested the F[i,j]
term is output as an emissivity value. Although the area term is not used, it can be
specified for reference purposes and is assumed to be the area of the i-th node.
Main Index
288 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
MPID Emissivity or Transmissivity MPID number. MPID should be zero for resistor
Subtype 4, Subtype 5, or Subtype 6.
A
Subtype: 15 R = --------------------------------------------------------------------
⎛ ⎛ -----
1⎞ ⎛ 1⎞
- + ------ + --------- 1
- – 2.0⎞
⎝ ⎝ e1⎠ ⎝ e2⎠ F12 ⎠
The variable gap resistor is between two surfaces where both emissivities are
defined by a material property even if one is a constant. Since the form factor will
be one for this equation to be valid as used, it is not necessary to input a form factor,
one will be assumed.
codeindent10
0.73118 43.2 15.7
This defines a VIEW FACTOR value of 0.73118, AREA = 43.2, and VFDIST = 15.7.
Parameter Description
VIEW Radiative resistor’s view factor (Subtype 2, Subtype 3, Subtype 7, and Subtype 8) is
FACTOR one of two constants multiplied together to compute the resistor’s value (Subtype 4),
the product of the resistor area and the view factor (Subtype 9 through Subtype 12),
the reciprocal of resistor’s value (Subtype 5), or is the resistor’s emissivity
(Subtype 6 only). VIEW FACTOR may not be left blank for any of the subtypes. A
numeric value must be entered (i.e., enter a 0 if VIEW FACTOR is not applicable
to the resistor subtype, e.g., Subtype 1).
AREA Surface area associated with the radiative resistor (Subtype 1 through Subtype 3 and
Subtype 6 through Subtype 8), or else is simply one of two constants multiplied
together to compute the resistor’s value (Subtype 4), it could also be ignored (or left
blank) for Subtype 5 and Subtype 9 through Subtype 12.
VFDIST View factor distance used with an extinction coefficient to calculate transmissivity
for resistor Subtype 7, Subtype 8, Subtype 11, and Subtype 12. VFDIST is ignored
for the other resistor subtypes and may be left blank.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 289
Network Construction
Subtype: 1 R11201102345
0.021.73
Defines a gray resistor between surface node 11 and radiosity node 2. MPID 102345 will be used to
calculate the temperature-dependent emissivity. The view factor field is given as 0.0 and will be
ignored by QTRAN (but must be there as a spacer), and the surface area is given as 21.73.
Subtype: 2 R212399245
0.012415.78
Defines a gray radiative resistor between radiosity nodes 21 and 23. The temperature of node 99 and
MPID 45 will be used to compute the participating media transmissivity. The view factor is given as
0.0124 and the surface area for the resistor is given as 15.78.
Subtype: 3 R141514388
0.01240.187
Defines a gray radiative resistor between participating media node 14 and radiosity node 15. The
transmissivity will be calculated from material property 88 using the temperature of node 14 (given as
both NODE1 and NODE3 here). The view factor is given as 0.0124 and the surface area is given as
0.187.
Subtype: 4 R7778040
0.8923.78
Defines a gray radiative resistor between nodes 77 and 78. Nodes 77 and 78 may be any type of
radiation network node (surface, radiosity, or participating media). The view factor value (or first
constant) is given as 0.89 and the surface area (or second constant) is given as 23.78.
Subtype: 5 R888991050
89.76
Defines a gray radiative resistor between nodes 88 and 8991. The input value is 89.76, which is the
reciprocal of the resistance.
Subtype: 6 R1019060
7.890E-01 23.889
Defines a gray radiative resistor between nodes 101 and 9. The constant emissivity has been given as
7.890E-01 and the surface area has been given as 23.889.
Subtype: 7 R667767789089
0.0012385.7761.045E+02
Defines a gray radiative resistor between radiosity nodes 66 and 77. The temperature of node 67 will
be used with MPID 89089 to calculate an extinction coefficient. The view factor has been given as
0.00123, the surface area as 85.776, and the view factor distance as 1.045E+02.
Main Index
290 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Subtype: 8 R655656082525
0.128.9E+0284.88E+03
Defines a gray radiative resistor between participating media node 655 and radiosity node 656. The
temperature of node 655 will be used to calculate the extinction coefficient since NODE3 was entered
as 0. The MPID of the extinction coefficient is 2525. The view factor is given as 0.12, the surface area
as 8.9E+02, and the view factor distance as 84.88E+03.
Subtype: 9 R212399945
0.0124
Defines a gray radiative resistor between radiosity nodes 21 and 23. The temperature of node 99 and
MPID 45 will be used to compute the participating media transmissivity. The product of the surface
area and the view factor is given as 0.0124.
Subtype: 10 R1415l141088
0.0124
Defines a gray radiative resistor between participating media node 14 and radiosity node 15. The
transmissivity will be calculated from material property 88 using the temperature of node 14 (given as
both NODE1 and NODE3 here). The product of the surface area and the view factor is given as 0.0124.
Subtype: 11 R6677671189089
0.001230.01.045E+02
Defines a gray radiative resistor between radiosity nodes 66 and 77. The temperature of node 67 will
be used with MPID 89089 to calculate an extinction coefficient. The product of the surface area and
the view factor has been given as 0.00123, the AREA parameter (not used for this resistor subtype, but
still necessary as a placeholder) has been given as 0.0, and the view factor distance as 1.045E+02.
Subtype: 12 R6556560122525
0.12084.88E+03
Defines a gray radiative resistor between participating media node 655 and radiosity node 656. The
temperature of node 655 will be used to calculate the extinction coefficient since NODE3 was entered
as 0. The MPID of the extinction coefficient is 2525. The product of the surface area and the view factor
is given as 0.12, the AREA parameter (not used for this resistor subtype, but necessary as a placeholder)
is given as 0.0, and the view factor distance as 84.88E+03.
Subtype: 13 R26627701335721
0.0044.4
Defines a gray radiative resistor between nodes 266 and 277. Although time will usually be the
independent variable for material properties with this option, if temperature is the independent variable,
node 266 will be used to calculate view factor or script F. The view factor has been given as 0.0 value
as a place holder. The surface area is 44.4. If the independent variable is temperature for MPID 35721
it must be specified in calculation units.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 291
Network Construction
Subtype: 14 R36637701455721
0.0055.5
Defines a gray radiative resistor between nodes 366 and 377. Although time will usually be the
independent variable for material properties with this option, if temperature is the independent variable,
node 366 will be used to calculate view factor or script F. The view factor has been given as 0.0 value
as a place holder. The surface area of 55.5 is not used in determining the resistor value but can be
specified for reference purposes. If the independent variable is temperature for MPID 55721 it must be
specified in calculation units.
Subtype: 15 R 444 222 0 15 123417
Main Index
292 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
The potential used for calculating the heat flow across wavelength-dependent resistors is not the usual σ
* T4 used for gray radiative resistors. Instead, the potential that is used is FRAC * σ * T4, where FRAC
is a number between 0.0 and 1.0 and is a fractional multiplier that represents the amount of energy in the
wave band η-1 to η-2 for which the resistor is valid. The net rate of heat from node 1 to node 2 is thus
seen to be given by the following expression:
4 4
σ * ( FRAC [ 1 ] * T [ 1 ] – FRAC [ 2 ] * T [ 2 ] )
Q [ 1-->2 ] = ----------------------------------------------------------------------------------------------------------------------------
-
R
FRAC[1] is the fraction of the black-body radiation potential to be found between η-1 and η-2 at
temperature T[1], and FRAC[2] is the fraction for T[2]. Strictly speaking, there is no way to incorporate
the value of FRAC[1] and FRAC[2] into the R value. This has been a fairly common mistake for many
users of other existing thermal programs in the past.
Example
W 10 20 30 2 15 23.7
This declares that a wavelength-dependent resistor is connected to nodes 10 and 20, that the
transmissivity will be evaluated according to the temperature of node 30, the resistor subtype is 2, the
MPID number for the resistor is 15, and the distance between surfaces is 23.7.
Parameter Description
RES-TYPE A character that defines the resistor type. In this case, RES-TYPE is entered as W to
identify a wavelength and temperature or time dependent thermal radiation resistor.
NODE1 Node 1 of the wavelength and temperature or time-dependent thermal radiation
resistor. For resistor Subtype 1, NODE1 should be a surface node. For Subtype 2,
NODE1 should be a radiosity node. For Subtype 3, NODE1 should be a
participating media node (e.g., a gas temperature node). The temperature of NODE1
is used to evaluate the temperature-dependent wave band emissivity (E) for Subtype
1.
NODE2 Node 2 of the wavelength and temperature or time-dependent thermal radiation
resistor. NODE2 must be a radiosity node, participating media node, or black-body
node for all of the resistor subtypes.
NODE3 Node 3 of the wavelength and temperature or time-dependent thermal radiation
resistor. NODE3 is used only as a reference temperature for computing the
participating media temperature-dependent wave band transmissivity (t). If input as
zero, it will be set to NODE1. If a resistor subtype does not require a NODE3 value,
enter a 0 for NODE3.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 293
Network Construction
Main Index
294 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
This resistor type is used between a gray surface and a radiosity node, with an
emissivity that is taken from a material property (MPID).
1
Subtype: 2 R = ----------------------------------------------------------------
F [ i, j ] * A [ i ] * τ [ gas ]
This resistor type is used between radiosity nodes, and with a time or temperature
dependent participating media whose transmissivity is taken directly from a material
property (MPID).
1
Subtype: 3 R = ---------------------------------------------------------------------------------------
F [ i, gas ] * A [ i ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
The view factor is between the surface i and the gas (or other participating media
node). The transmissivity of the gas (or participating media) is taken from a material
property.
Subtype: 4 1
R = ------------------------------------
F [ i, j ] * A [ i ]
This resistor type may be used anywhere that material properties are constant. It
would normally be used as a view factor resistor between radiosity nodes, but the F
and A values are entered as simple constants and hence could be anything
appropriate for a radiative resistor of this formulation. Since there is no data for
transmissivity, the transmissivity of the resistor is implicitly assumed to be 1.0.
1
Subtype: 5 R = ---
F
This resistor type may be used anywhere that material properties are constant. It
would normally be used as a view factor resistor between two radiosity nodes, but
the F value is a simple constant and hence could be anything appropriate for a
radiative resistor of this formulation.
Important: This resistor type is used when a minimum of calculations are desired,
thus for this type only the reciprocal of the resistance is input.
1–e
Subtype: 6 R = ----------------
e * A
This resistor type may be used as a surface resistor, with the value given for e being
the emissivity. This resistor subtype may be used anywhere the emissivity is
constant. Because the emissivity is assumed to be constant, it is faster to evaluate
than Subtype 1.
1
Subtype: 7 R = ----------------------------------------------------------------
F [ i, j ] * A [ i ] * τ [ gas ]
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 295
Network Construction
This resistor type is used between radiosity nodes. τ is calculated from an extinction
coefficient identified by the resistors MPID and from a view factor distance.
Specifically, τ[gas] = EXP(-S * P), where S is the view factor distance and P is the
extinction coefficient calculated from the material property (MPID) of the resistor.
1
Subtype: 8 R = ---------------------------------------------------------------------------------------
F [ i, gas ] * A [ i ] * ( 1 – τ [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
τ is calculated from an extinction coefficient identified by the resistor’s MPID and
from a view factor distance. The transmissivity value τ is calculated in the same
manner as for Subtype 7 above.
Subtype: 9 1
R = -----------------------------------------------
AF [ i, j ] * τ [ gas ]
This resistor type is used between radiosity nodes, and with a temperature dependent
participating media whose transmissivity is taken directly from a material property
(MPID). This is the same as Subtype 2, except that F[i,j] and A[i] have been
combined as AF[i,j] for computational efficiency.
1
Subtype: 10 R = ---------------------------------------------------------------------
AF [ i, gas ] * ( 1 – t [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
The view factor is between the surface i and the gas (or other participating media
node). The transmissivity of the gas (or participating media) is taken from a material
property. This is the same as Subtype 3, except that F[i,j] and A[i] have been
combined as AF[i,j] for computational efficiency.
1
Subtype: 11 R = ----------------------------------------------
AF [ i, j ] * t [ gas ]
This resistor type is used between radiosity nodes. τ is calculated from an extinction
coefficient identified by the resistor’s MPID and from a view factor distance.
Specifically, τ[gas] = EXP(-S * P), where S is the view factor distance and P is the
extinction coefficient calculated from the material property (MPID) of the resistor.
This is the same as Subtype 7, except that F[i,j] and A[i] have been combined as
AF[i,j] for computational efficiency.
Subtype: 12 1
R = --------------------------------------------------------------------
-
AF [ i, gas ] * ( 1 – t [ gas ] )
This resistor type is used between a radiosity node and a participating media node.
τ is calculated from an extinction coefficient identified by the resistor’s MPID and
from a view factor distance. The transmissivity value τ is calculated in the same
manner as for Subtype 7. This is the same as Subtype 8, except that F[i,j] and A[i]
have been combined as AF[i,j] for computational efficiency.
1
Subtype: 13 R = ------------------------------------
F [ i, j ] * A [ i ]
Main Index
296 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
This resistor type may be used between any nodes. The F[i,j] term is defined by a
material property (MPID) whose independent variable is either time or the
temperature of the i-th node in calculation units. This is normally used to define
dynamic viewfactor and thus would couple radiation between radiosity nodes.
However, if both surfaces have constant emissivities then the F term can be thought
of as a script F which includes any non black characteristics. The area term is a
constant for this evaluation. Since there is no data for transmissivity, the
transmissivity of the resistor is implicitly assumed to be 1.0. If diagnostic output is
requested the F[i,j] term is output as an emissivity value.
1
Subtype: 14 R = ----------------------
AF [ i, j ]
This resistor type may be used between any nodes. The AF[i,j] term is defined by a
material property (MPID) whose independent variable is either time or the
temperature of the i-th node in calculation units. This is normally used to define
dynamic viewfactor and thus would couple radiation between radiosity nodes.
However, if both surfaces have constant emissivities then the AF term becomes a
script F which includes any non black characteristics. The area term is a constant for
this evaluation. Since there is no data for transmissivity, the transmissivity of the
resistor is implicitly assumed to be 1.0. If diagnostic output is requested the F[i,j]
term is output as an emissivity value. Although the area term is not used, it can be
specified for reference purposes and is assumed to be the area of the i-th node.
MPID This is the material property identification (MPID Number, Function Type,
Temperature Scale, Factor and Label, 263 number that is used here to identify the
emissivity or transmissivity of the wavelength and temperature or time-dependent
radiative resistor.
VFDIST This is the View factor Distance, used for resistor Subtypes 7, 8, 11 and 12, along
with the material property identified with MPID to compute a transmissivity for the
resistor. For Subtypes 7, 8, 11, and 12, MPID is assumed to identify a material
property that will be used as an extinction coefficient. The transmissivity Tau is then
computed as τ = EXP( -VFDIST * k ), where k is the extinction coefficient
calculated from an MPID.
Example
0.0 14.7 1.1 3.3
This enters a VIEW FACTOR value of 0.0, an AREA value of 14.7, a η-1 value of 1.1 microns, and a η-
2 value of 3.3 microns.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 297
Network Construction
Parameter Description
VIEW Wavelength and temperature-dependent resistor’s view factor for Subtypes 2, 3, 7,
FACTOR 8, 11, and 12, constant emissivity (Subtype 6), constant transmissivity (Subtype 4),
reciprocal of the resistor’s value (Subtype 5), or the product of the resistor area and
the view factor (Subtypes 9-12). VIEW FACTOR is ignored for resistor Subtype 1.
If defining resistor Subtype 1, enter a zero for VIEW FACTOR.
AREA Surface area associated with the wavelength and temperature or time dependent
thermal radiation resistor. Area should be entered as 0.0 for Subtypes 9-12.
η-1 Shortest wavelength of the wave band interval for which the wavelength and
temperature or time-dependent resistor is to be used. h-1 should be entered in units
of micrometers only.
η-2 Longest wavelength of the wave band interval for which the wavelength and
temperature or time dependent resistor is to be used. h-2 should be entered in units
of micrometers only.
Main Index
298 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Subtype: 1 W 11 2 0 1 102345
0.0 21.73
Defines a resistor between surface node 11 and radiosity node 2. MPID 102345 will be used to calculate
the temperature dependent emissivity. The view factor field is given as 0.0 and will be ignored by
QTRAN (but must be there as a spacer), and the surface area is given as 21.73. The wave band is
defined to lie between 0.0 and 5.0 microns.
Subtype: 2 W 21 23 99 2 45
0.01240.1870.130.89
Defines radiative resistor between participating media node 14 and radiosity node 15. The
transmissivity will be calculated from material property 88 using the temperature of node 14 (given as
both NODE1 and NODE3 here). The view factor is given as 0.0124 and the surface area is given as
0.187. The wave band is defined to be between 0.13 and 0.89 microns.
Subtype: 4 W 77 78 0 4 0
0.8923.789.81.0E+10
Defines a gray radiative resistor between nodes 77 and 78. Nodes 77 and 78 may be any type of
radiation network node (surface, radiosity, or participating media). The view factor value (or first
constant) is given as 0.89 and the surface area (or second constant) is given as 23.78. The wave band
is defined to be between 9.8 and 1.0E+10 microns.
Subtype: 5 W888991050
89.760.01.28.9
Defines a radiative resistor between nodes 88 and 8991. The input value is 89.76, which is the
reciprocal of the resistance. The AREA value of 0.0 is entered as a required spacer between the VIEW
FACTOR value and the LAMBDA-1 value. The wave band is defined to be between 1.2 and 8.9
microns.
Subtype: 6 W1019060
7.890E-0123.8891.0E-011.2E+01
Defines a radiative resistor between nodes 101 and 9. The constant emissivity has been given as
7.890E-01 and the surface area has been given as 23.889. The wave band has been defined to be
between 1.0E-01 and 1.2E+01 microns.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 299
Network Construction
Subtype: 7 W6677677890891.045E+02
0.0012385.7760.05.7
Defines a radiative resistor between radiosity nodes 66 and 77. The temperature of node 67 will be used
with MPID 89089 to calculate an extinction coefficient. The view factor has been given as 0.00123,
the surface area as 85.776, and the view factor distance as 1.045E+02. The wave band has been defined
to be between 0.0 and 5.7 microns.
Subtype: 8 W65565608252584.88E+03
0.128.9E+021.28.9
Defines a radiative resistor between participating media node 655 and radiosity node 656. The
temperature of node 655 will be used to calculate the extinction coefficient since NODE3 was entered
as 0. The MPID of the extinction coefficient is 2525. The view factor is given as 0.12, the surface area
as 8.9E+02, and the view factor distance as 84.88E+03. The wave band has been defined to be between
1.2 and 8.9 microns.
Subtype: 9 W212399945
0.01240.05.09.8
Defines a radiative resistor between radiosity nodes 21 and 23. The temperature of node 99 and MPID
45 will be used to compute the participating media transmissivity. The area view factor product is given
as 0.0124 and the AREA parameter (not used by this resistor subtype) as 0.0. The wave band is given
as 5.0 to 9.8 microns.
Subtype: 10 W1415141088
0.01240.00.130.89
Defines a radiative resistor between participating media node 14 and radiosity node 15. The
transmissivity will be calculated from material property 88 using the temperature of node 14 (given as
both NODE1 and NODE3 here). The area view factor product is given as 0.0124 and the AREA
parameter (not used by this resistor subtype) as 0.0. The wave band is defined to be between 0.13 and
0.89 microns.
Subtype: 11 W66776711890891.045E+02
0.001230.00.05.7
Defines a radiative resistor between radiosity nodes 66 and 77. The temperature of node 67 will be used
with MPID 89089 to calculate an extinction coefficient. The view factor has been given as 0.00123;
the AREA parameter (not used by this resistor subtype) as 0.0; and the view factor distance as
1.045E+02. The wave band has been defined to be between 0.0 and 5.7 microns.
Subtype: 12 W655656012252584.88E+03
0.12084.88E+03
Main Index
300 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Defines a radiative resistor between participating media node 655 and radiosity node 656. The
temperature of node 655 will be used to calculate the extinction coefficient since NODE3 was entered
as 0. The MPID of the extinction coefficient is 2525. The area view factor product is given as 0.12; the
AREA parameter (not used by this resistor subtype) as 0.0; and the view factor distance as 84.88E+03.
The wave band has been defined to be between 1.2 and 8.9 microns.
Subtype: 13 W21123101310
0.087.651.219.8
Defines a radiative resistor between nodes 211 and 231. MPID 10 will be used to specify the view
factor. The view factor is given as 0.0 only as a place holder and the surface area for the resistor is given
as 87.65. The wave band is given as 1.2 to 91.8 microns. The temperature of node 211 will be used if
the viewfactor is temperature dependent and the material property must be specified in calculation
units. Time is the most probable independent variable for this subtype.
Subtype: 14 W111131014100
0.033.330.21.1
Defines a radiative resistor between nodes 111 and 131. MPID 100 will be used to specify the view
factor area product. The view factor is given as 0.0 only as a place holder and the surface area of 33.33
is for reference only. Some value must be specified as a place holder but it is not used to define the
resistor. The wave band is given as 0.2 to 1.1 microns. The temperature of node 111 will be used if the
viewfactor is temperature dependent and the material property must be specified in calculation units.
Time is the most probable independent variable for this subtype.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 301
Network Construction
Note: This data must be input manually. It cannot be generated by Patran and PATQ. It is
preferable that these declarations are placed in the QINDAT file. But they may be placed
in any file that is referenced by an $INSERT FILE_NAME command in the QINDAT file
inside of the resistor definition block only.
Example
L 7 20 1 2 3 4 3 0
This begins a 1-D mesh generation data set between nodes 7 and 20 by increments of 1 with MPID
numbers of 2, 3, and 4 for conductivity, density, and specific heat (respectively), mesh Subtype 3 (polar),
and PHID of 0 (this means no phase change MPID will be assigned).
Main Index
302 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
RES-TYPE Character that defines the resistor type. In this case, RES-TYPE is entered as L to
identify a 1-D automatic mesh generation data set.
NODE_1 First node, or starting node, for the 1-D automatically generated mesh section.
NODE_N Last node, or ending node, for the 1-D automatically generated mesh section.
NODE_INC Node number increment for the mesh and may be either positive or negative. For
example, if NODE_1 = 1 and NODE_N = 7 and NODE_INC = 2, the node numbers
of the mesh will be 1, 3, 5, and 7. If NODE_1 = 10 and NODE_N = 6 and
NODE_INC = -2, the node numbers will be 10, 8, and 6.
K_MPID Material property identification number for the thermal conductivity of the mesh
section. See MPID Number, Function Type, Temperature Scale, Factor and Label,
263.
RHO_MPID Material property identification number for the density of the mesh section. See
MPID Number, Function Type, Temperature Scale, Factor and Label, 263.
CP_MPID Material property identification number for the specific heat of the mesh section.
See MPID Number, Function Type, Temperature Scale, Factor and Label, 263.
SUBTYPE Mesh subtype, where:
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 303
Network Construction
where:
LENGTH is the spacing between the first and second node, P1 is a point packing
factor, n is the number of the resistor in the one-dimensional system, and L[n] is the
length of the n'th resistor.
The length of the first resistor (LENGTH) is related to the total slab length and the
number of nodes to be used as follows:
LSLAB * ( P1 – 1.0 )
RCLI = ---------------------------------------------------------------------------------------------------
-
( NODES – 1.0 )
( P1 – 1.0 )
LENGTH = RCLI
Important: The number of resistors is one less than the number of nodes, LSLAB
is the total thickness of the slab being analyzed, and RCLI is a unit
thickness which is the distance between the first two nodes, or the
thickness of the first resistor which is input to QTRAN as the variable
LENGTH.
3. Polar mesh.
4. Spherical mesh.
5. LaGrange Cubic Finite Element Cartesian mesh.
Important: The resistors generated by this technique are purely mathematical in
nature and do not have a physical significance. For example, a number
of the resistors generated will have negative area/length ratios that do
not make any physical sense. However, they are quite correct and do
yield highly accurate results (i.e., they should approach 6th order
accuracy). Do not be alarmed by the generation of negative resistors
whenever finite element data is transformed into resistor data. The
capacitor volumes, on the other hand, should always be positive.
PHID Phase change MPID to be associated with the capacitors contained in the
automatically generated mesh section. See Material Properties, 263.
Example
1.02.03.0
This enters a value of 1.0 for LENGTH, 2.0 for AREA, 3.0 for P1.
Main Index
304 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
LENGTH Distance between nodes in the mesh section. For SUBTYPE = 2, this is the distance
between the first two nodes of this mesh section where all other distances for
SUBTYPE = 2 meshes are set as follows:
where:
LSLAB * ( P1 – 1.0 )
RCLI = ---------------------------------------------------------------------------------------------------
-
( NODES – 1.0 )
( P1 – 1.0 )
LENGTH = RCLI
Important: The number of resistors is one less than the number of nodes, LSLAB
is the total thickness of the slab being analyzed, and RCLI is a unit
thickness which is the distance between the first two nodes, or the
thickness of the first resistor which is input to QTRAN as the variable
LENGTH.
AREA Cross-sectional area of the mesh section for SUBTYPE = 1, 2, or 5. AREA is
ignored for SUBTYPE = 3 or 4. Note that Subtypes 3 and 4 assume a full cylinder
or full sphere, respectively.
P1 Mesh parameter 1 (ignored for SUBTYPE = 1 or 5).
For SUBTYPE = 2, P1 is used to gradually increase the mesh spacing so that the
distances between nodes and the length L(n) for the n'th resistor is:
(n - 1)
L(n) = LENGTH * [ P1 ]
For SUBTYPE = 3 or 4, P1 is the radial distance between the first node of the mesh
section and the origin of the cylindrical or spherical coordinate system.
When defining mesh type (SUBTYPE) 5, note that the starting and ending nodes and
node number increment must be compatible with 4-node finite elements. For
example, if there are N elements in the mesh section there will be N * 3+1 nodes
associated with that section. Any other arrangement will cause an erroneous mesh
to be generated.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 305
Network Construction
MASS_FLOW_MPID
This section describes how to define data for an advective resistor. Advective resistors are required when
it is necessary to model the energy carried along with a mass stream that is entering a given capacitor’s
volume. The heat flow relation is
Q[1-->2] = MASS_FLOW * Cp * (T[1] - T[2])
where the specific heat is based on the effective average value integrated between temperatures T[1] and
T[2], and based on a flow of temperature step defined by CPDII5, and MASS_FLOW is the mass rate of
flow. Because difference schemes for this type of calculation are generally restricted to one-sided upwind
or donor cell schemes due to stability considerations, heat will be carried only to the downstream node
and not to the upstream node. Node 1 is the upstream node if the mass flow rate is positive, and Node 2
is the upstream node if the mass flow rate should become negative. As a result of the PATQ translation
(menu pick 2), these declarations are placed in the RESDAT file.
To add an advective resistor to the model, simply enter the resistor data as shown in the following
examples. When all the thermal resistors are defined, enter a dollar sign ($) in column 1 of the input data
file and proceed to Capacitor Data, 320. To define more resistors, proceed to the appropriate Section
(p. 276) to (p. 306) and continue to enter thermal resistor data.
Example 1
A117 2314.724
Example 1 defines an advective resistor between node 1 (upstream) and node 17 (downstream) with a
specific heat evaluated according to MPID 23 and a mass flow rate given by the product of 14.7 and the
value of material property 24.
Example 2
A 21 23 23 15.2
Example 2 defines an advective resistor between node 21 (upstream) and node 22 (downstream) with the
specific heat evaluated according to MPID 23 and with a constant mass flow rate of 15.2.
The advective resistor data items (RES-TYPE, NODE1, NODE2,
CP_MPID,MASS_FLOW_CONSTANT, and MASS_FLOW_ MPID) are defined below.
Main Index
306 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
RES-TYPE Character that defines the resistor type. In this case, RES_TYPE is
entered as A to identify an advective resistor.
NODE1 Node 1 of the advection resistor. NODE1 is the upstream or upwind
node of the advective resistor if the mass flow rate is positive.
NODE2 Node 2 of the advection resistor. NODE2 is the downstream or
downwind node of the advective resistor if the mass flow rate is
positive.
CP_MPID Material property identification number for the specific heat of the
mass that is flowing for this resistor. See MPID Number, Function
Type, Temperature Scale, Factor and Label, 263.
MASS_FLOW_CONSTANT Constant mass rate of flow for this resistor if no
MASS_FLOW_MPID is given. If a MASS_FLOW_MPID is given,
this value will scale the value returned by the “material property”
referenced by the MASS_FLOW_MPID.
MASS_FLOW_MPID Material property which will be used to compute a time or
temperature-dependent flow rate. If no MPID is given for
MASS_FLOW_MPID, the MASS_FLOW_CONSTANT is used for
the flow rate. If MASS_FLOW_MPID is given, the value of the
material property referenced by this MPID will be multiplied by
MASS_FLOW_CONSTANT to compute a mass flow rate.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 307
Network Construction
2. Enter the data for the resistor for Hydraulic Resistor Geometric Properties, 308. This data defines
all Geometric Properties (GP) such as characteristic diameter, cross-sectional areas, and distance
fluid travels etc. The number of entries is dependent on the fluid resistor type.
3. Enter all data for the Hydraulic Resistor Material Properties, 309. This data is used to identify
where the material properties that are required for specific resistor configurations are to be found.
4. When all the thermal resistors are defined, place a dollar sign ($) in column 1 of the input data file
and proceed to Capacitor Data, 320. To define another thermal resistor, proceed to the resistor
data section (p. 276) to (p. 306) that applies to the next resistor that you wish to define.
This section describes how to identify a given thermal resistor as a fluid resistor, to define its node
numbers, and to specify the resistor fluid configuration.
Example 1
F 1 17 3
Example 1 defines a hydraulic resistor between node 1 (upstream) and node 17 (downstream). Hydraulic
configuration 3 will be used to interpret the meaning of the geometric parameters and material property
ID’s specified.
Example 2
F 21 22 10
Example 2 defines a hydraulic resistor between node 21 (upstream) and node 22 (downstream) with
hydraulic configuration 10 used to interpret the meaning of the geometric parameters and material
property IDs specified.
Main Index
308 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Parameter Description
RES-TYPE Character that defines the resistor type. In this case, RES_TYPE is entered as F to
identify a hydraulic resistor.
NODE1 Node 1 of the hydraulic resistor. NODE1 is the upstream or upwind node of the
hydraulic resistor if the mass flow rate is positive.
NODE2 Node 2 of the hydraulic resistor. NODE2 is the downstream or downwind node of
the hydraulic resistor if the mass flow rate is positive.
FCFIG Fluid configuration for this hydraulic resistor. The configuration denotes the type of
fluid resistor and how the geometric properties are to be interpreted and what the
material properties are to designate. Valid entries are between 1 and 12.
Example
24.7 23.2 0.0 14.8 29.9
15.6 18.9
/
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 309
Network Construction
This enters 7 GP values of 24.7, 23.2, 0.0, 14.8, 29.9, 15.6, and 18.9, in that order using free format input.
Parameter Description
GP Hydraulic resistor’s Geometric Properties such as length, diameter, cross-
sectional area, or gravitational constants. The exact meaning of each GP value
varies for each configuration. QTRAN will continue reading GP values until it
encounters a slash (/) in column 1 of the input data file. The procedure for entering
GP values is to enter all GP values followed by an input data file line with a slash
in column 1. Proceed on to Hydraulic Resistor Material Properties, 309.
When GP values at the end of the required list are zero, they need not be input. All
intermediate zeroes must be included as placeholders.
Example
1 7 4 6
15 23
/
This declares MPID values of 1, 7, 4, 6, 15, and 23.
Parameter Description
MPID Material Property Identification numbers for the hydraulic resistors. See MPID
Number, Function Type, Temperature Scale, Factor and Label, 263. Material
properties include the fluid density, viscosity, and specific heat plus other flow
parameters that can be a function of time or temperature such as loss coefficients,
friction factors, pump head, etc. The material properties that correspond to each
MPID entry are listed for each fluid configuration option in the following option
definition section. After all MPID values have been entered, simply enter a slash (/)
in column one of the next line of the input data file.
When MPID values at the end of the required list are zero, they need not be input.
All intermediate zeroes must be included as placeholders.
Main Index
310 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
where:
• Hydraulic_Diameter is a cross-sectional area divided by the wetted perimeter. Internally a
circular cross section is assumed for any calculation which relate area and diameter.
• Cross_Sectional_Area is the area that supports the flowing fluid.
• Length is the total travel of the fluid within a resistor. This does not have to be equal to the
distance between the beginning and end of a resistor. One example would be a coiled tubing in
which the inlet and outlet are very close but the actual distance the fluid travels is much greater
than the distance between the inlet and outlet of the coil.
• DX is the displacement of NODE2 relative to NODE1 in the X global axis direction. This
distance is used to determine gravitational head changes.
• DY is the displacement of NODE2 relative to NODE1 in the Y global axis direction. This
distance is used to determine gravitational head changes.
• DZ is the displacement of NODE2 relative to NODE1 in the Z global axis direction. This
distance is used to determine gravitational head changes.
• Density is the density of the fluid flowing. Units of specific weight are used to be consistent with
the thermal solution. Internal units conversion to mass density are performed as necessary.
• Viscosity is the dynamic viscosity of the fluid.
• Specific_Heat is of the fluid.
• Surface_Roughness is the characteristic roughness of the tubing.
• Loss_Coefficient for determining added head loss due to added flow restrictions such as
constrictions, orifices, vanes, bends, etc.
• Friction_Factor is used to calculate head loss due to the viscous effect of the fluid flowing in a
tube.
• Buoyancy is the gravitational head created by the temperature gradient working against a
gravitational field. Buoyancy can be modeled as the reciprocal of the compressibility factor.
• There are no material properties defined.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 311
Network Construction
FCFIG = 2, Tubing with constant physical and material properties with friction factor evaluated by
Patran Thermal Moody equation
.
Main Index
312 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 313
Network Construction
where:
• Density of the fluid flowing. Units of specific weight are used to be consistent with the thermal
solution. Internal units conversion to mass density are performed as necessary.
• Viscosity is the dynamic viscosity of the fluid.
• Specific_Heat of the fluid.
• Pump_Head - The pump head must always be positive.
• There are no material properties defined.
/
MPID_RHO MPID_MU MPID_CP
MPID_HEAD
/
where:
• MPID_RHO is the time or temperature-dependent density of the fluid and is defined as a
material property. Units of specific weight are used to be consistent with the thermal solution.
Internal units conversion to mass density are performed as necessary.
• MPID_MU is the time or temperature-dependent viscosity of the fluid and is defined as a
material property.
• MPID_CP is the time or temperature-dependent specific heat of the fluid and is defined as a
material property.
• MPID_HEAD is the time or temperature-dependent head operating on the fluid and is defined
as a material property. The pump head must always be positive.
Main Index
314 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
where:
• Density of the fluid flowing. Units of specific weight are used to be consistent with the thermal
solution. Internal units conversion to mass density are performed as necessary.
• Viscosity is the dynamic viscosity of the fluid.
• Specific_Heat of the fluid.
• Turbine_Head - The turbine head must always be negative.
• There are no material properties defined.
/
MPID_RHO MPID_MU MPID_CP
MPID_HEAD
/
where:
• MPID_RHO is the time or temperature-dependent density of the fluid and is defined as a
material property. Units of specific weight are used to be consistent with the thermal solution.
Internal units conversion to mass density are performed as necessary.
• MPID_MU is the time or temperature-dependent viscosity of the fluid and is defined as a
material property.
• MPID_CP is the time or temperature-dependent specific heat of the fluid and is defined as a
material property.
• MPID_HEAD is the time or temperature-dependent head operating on a turbine by the fluid and
is defined as a material property. The turbine head must always be negative.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 315
Network Construction
where:
Main Index
316 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
where:
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 317
Network Construction
• Density is the density of the fluid flowing. Units of specific weight are used to be consistent with
the thermal solution. Internal units conversion to mass density are performed as necessary.
• Viscosity is the dynamic viscosity of the fluid.
• Specific_Heat is of the fluid.
• Surface_Roughness is the characteristic roughness of the tubing.
• Loss_Coefficient for determining added head loss due to added flow restrictions such as
contractions, orifices, vanes, bends, etc.
• Buoyancy is the gravitational head created by the temperature gradient working against a
gravitational field. Buoyancy can be modeled as the reciprocal of the compressibility factor.
• There are no material properties defined.
FCFIG = 10, Check Valve with Constant Physical and Variable Material Properties
.
where:
Main Index
318 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
• Loss_Coefficient for determining added head loss due to added flow restrictions such as
contractions, orifices, vanes, bends, etc. This value is used as a scale factor on the material
property value specified by MPID_LOSS_COEFF.
• MPID_RHO is the time or temperature-dependent density of the fluid and is defined as a
material property. Units of specific weight are used to be consistent with the thermal solution.
Internal units conversion to mass density are performed as necessary.
• MPID_MU is the time or temperature-dependent viscosity of the fluid and is defined as a
material property.
• MPID_CP is the time or temperature-dependent specific heat of the fluid and is defined as a
material property.
• MPID_LOSS_COEFF is the time or temperature-dependent loss coefficient operating on the
fluid and is defined as a material property.
• MPID_BETA is the time or temperature-dependent buoyancy term and is defined as a material
property. It represents the gravitational head created by the temperature gradient working against
a gravitational field. Buoyancy can be modeled as the reciprocal of the compressibility factor.
• MPID_F is the time or temperature-dependent friction factor used to calculate head loss due to
the viscous effect of the fluid flowing in a tube and is defined as a material property. If this value
is zero, it is calculated by Patran Thermal using the built in Moody equations.
where:
• DX is the displacement of NODE2 relative to NODE1 in the X global axis direction. This
distance is used to determine gravitational head changes.
• DY is the displacement of NODE2 relative to NODE1 in the Y global axis direction. This
distance is used to determine gravitational head changes.
• DZ is the displacement of NODE2 relative to NODE1 in the Z global axis direction. This
distance is used to determine gravitational head changes.
• Density is the density of the fluid flowing. Units of specific weight are used to be consistent with
the thermal solution. Internal units conversion to mass density are performed as necessary.
• Viscosity is the dynamic viscosity of the fluid.
• Specific_Heat is of the fluid.
• There are no material properties defined.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 319
Network Construction
where:
• DX is the displacement of NODE2 relative to NODE1 in the X global axis direction. This
distance is used to determine gravitational head changes.
• DY is the displacement of NODE2 relative to NODE1 in the Y global axis direction. This
distance is used to determine gravitational head changes.
• DZ is the displacement of NODE2 relative to NODE1 in the Z global axis direction. This
distance is used to determine gravitational head changes.
• MPID_RHO is the time or temperature-dependent density of the fluid and is defined as a
material property. Units of specific weight are used to be consistent with the thermal solution.
Internal units conversion to mass density are performed as necessary.
• MPID_MU is the time or temperature-dependent viscosity of the fluid and is defined as a
material property.
• MPID_CP is the time or temperature-dependent specific heat of the fluid and is defined as a
material property.
Example
F 1 2 3
1.0000000E-01 7.8539830E-03 1.0000000E+01
1.0000000E+01 0.0000000E+00 0.0000000E+00
1.9999999E-04 1.0000000E+00 0.0000000E+00
/
1 2 3 4 6 5
/
This QTRAN input data defines a fluid configuration 3 hydraulic resistor with fluid flowing from nodes
1 to node 2. The GP values are: diameter = 0.1, cross- sectional area = 7.853983e-3, the resistor length
is 10.0 which is the same as the resistor displacement in the global x axis. The resistor displacement in
the y and z axis is 0.0. The tubing surface roughness is 0.0002 and the resistor has a loss coefficient scale
factor of 1.0. Friction factor scale factor is not supplied and a MPID_F material property is supplied, thus
Main Index
320 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Network Construction
a 1.0 is implied. If the MPID_F were 0 or not supplied, the friction factor would be calculated by Patran
Thermal. The MPID numbers of 1, 2, and 3 define the density, viscosity, and specific heat material
properties. The loss coefficient, buoyancy, and friction factor material properties are 4, 6, and 5
respectively.
Capacitor Data
CAP (keyword) NODE RHO CP VOL PHID
This section allows nodal capacitances (volumes and material property identification numbers (MPIDs))
for density, specific heats, and Phase Identification (PHID) data sets (see Material Properties, 263) to be
assigned to individual nodes. When all of the information necessary for the thermal simulation for this
section is entered, put a dollar sign ($) in column 1 of the input data file and go on to Microfunction Data,
322.
The capacitor values in this section will be placed in parallel with any capacitors generated by the
automatic mesh generators. As a result of the PATQ translation (menu pick 2), these declarations are
placed in the CAPDAT file.
Example
CAP 1 23 24 15.7E-05 0
This assigns a capacitor to node 1 with a density from MPID 23, a specific heat from MPID 24, a volume
of 15.7E-05, and a PHID (phase change MPID data set) of 0 (none).
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 321
Network Construction
Parameter Description
NODE) Node with which the capacitance is associated.
RHO) Identification number assigned to the material property that will be used for the
density of this node. See Material Properties, 263.
CP Identification number assigned to the material property that will be used for the
specific heat of this node. See Material Properties, 263.
VOL Volume associated with this capacitor.
PHID MPID phase change data set (see Material Properties, 263) that will be used in
calculating any potential phase change effects associated with this capacitor. If
no PHID set is to be assigned to this capacitor, simply enter a zero.
These five values must be entered for each nodal capacitance that is assigned, one
capacitance set at a time. For example, first enter the keyword CAP followed by
the values of NODE, RHO, CP, VOL, and PHID for one node, then enter another
five values for the next node, and so on until all values necessary for the thermal
simulation have been entered. When all values have been input, enter a dollar
sign ($) in column 1 of the input data file and proceed to Boundary Conditions,
322.
To perform steady-state calculations only, and if the QGLOBL global heat source
of Initially Fixed Nodes, 333 is zero, ignore the nodal capacitance data because it
will not be used for these calculations. Capacitance data is used only for transient
calculations, or when the QGLOBL per-unit-volume global heat source is to be
invoked.
Main Index
322 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
Boundary Conditions
This section is used to implement boundary conditions for the problem. The parameters and options
controlled by boundary conditions input are listed below.
Microfunction Data
This describes how QTRAN microfunctions are defined that in turn will be used to compose QTRAN
macrofunctions (macro functions are used for variable nodal heat sources and temperature controls). The
procedure used for defining QTRAN microfunctions is described below:
1. Enter all microfunction data for MFID, Independent Variable, and Function Type, 323. This data
defines the microfunction ID number (MFID), specifies the independent variable of the
microfunction (e.g., time, temperature, Δ temperature or average temperature, or Δ radiosity), and
gives the microfunction library option (see the function catalogue of Microfunction Library
(Ch. 10), for available function options).
2. Enter all microfunction data for Microfunction Parameters or Data Tables, 324. This is the
necessary tabular data or parameter data used with the microfunction library option to totally
define the microfunction. When all of the parameter or tabular data is entered, enter a slash (/) in
column one of the input data file.
3. When all of the microfunctions have been defined enter a dollar sign ($) in column one of the
input data file and proceed to Heat Source/Sink Macrofunction Definition, 325. If you wish to
define more microfunctions, return to Step 1 of this procedure and continue until all necessary
microfunctions have been defined.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 323
Boundary Conditions
Note: This data is not generated by Patran or PATQ. Use the system editor to generate this data.
This data is normally put in the file MICRODAT.
Example
MICRO 27 0 9
This begins a microfunction data packet for MFID 27, with 0 (time) as the argument, and option 9
(Hermite table) as the function type.
Main Index
324 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
Parameter Description
MFID Microfunction Identification number. Each microfunction must be
assigned a unique MFID number greater than zero. This MFID number
will be referenced by the macrofunctions, see (p. 325) through (p. 331), in
the same manner as a material property ID number (MPID) is referenced
by resistors and capacitors. This referencing scheme allows the same
microfunction to be used in many different macrofunctions.
ARGUMENT Identifies the microfunction independent variable as time, temperature
(T), Δ T, or a radiosity difference according to the following argument
code:
0 -- t (time)
1 -- T (temperature)
2 -- ΔT = T[1] - T[2] (temperature
difference)
3 -- σ * (T[1]4 - T[2]4) (radiosity difference)
Example
MICDAT 1.0 2.0 3.0 15.0
/
The example defines parameters P(1) to P(4) as 1.0, 2.0, 3.0, and 15.0, respectively. The / declares that
this is the end of the parameter data. How the parameters are used is dependent upon the microfunction
option.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 325
Boundary Conditions
Example
MICDAT 0.0 22.7
MICDAT 100.4 88.9
MICDAT 40.8 23.9
MICDAT 200.9 84.7
/
This example defines tabular data for a tabular microfunction. Note that there is only one data pair per
line. How the data pairs will be used is dependent upon the microfunction option.
Parameter Description
MICDAT Data that is used to define a specific microfunction. QTRAN now expects to read
parameters or tabular data pairs, depending upon the Function Library option that
you selected. If parameters are input, put as many parameters on each line as desired
(but at least 1). If tabular data is entered, put 2 and only 2 table entries on each line.
Each line must begin with the keyword MICDAT. The data is all free format input.
Linear tables require a minimum of two data pairs, whereas Hermite tables require
at least three data pairs.
When all of the parameters or table data pairs have been entered, enter a slash (/) in
column 1. To define more microfunctions, loop back to MFID, Independent Variable,
and Function Type, 323 and continue defining microfunctions until done. When no
more microfunctions are to be defined, simply enter a dollar sign ($) in column 1
and proceed on to Heat Source/Sink Macrofunction Definition, 325.
Main Index
326 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
As many heat source/sink macrofunctions may be assigned to any node. If more than one macrofunction
is assigned to a node, the node receives the summed output of the macrofunctions. Because a
macrofunction consists of microfunctions that are multiplied (or divided) by each other, it is allowed to
effectively add or multiply functions to arrive at the desired heat source/sink functional form. Division
is also possible, because microfunctions can be defined as the reciprocal of any option contained in the
Microfunction Library (Ch. 10) by placing a negative sign in front of the specified option. Microfunctions
can also be effectively used as arguments of other microfunctions to specify any nodal temperature as the
argument for the temperature-dependent microfunctions of a macrofunction, and to specify nodal
temperatures themselves by using temperature control macrofunctions. Note that User-Coded
microfunctions are yet another method of applying exotic boundary conditions. See User-Supplied
Subroutines (Ch. 11).
Note: QMACRO functions are normally generated by PATQ menu pick two and placed in the file
QMACRODAT.
Example
QMACRO 1 2 1 7 23.174
The example declares that a QMACROfunction data set is being assigned to node 1, is built from 2
microfunctions, that node number 1 is the first temperature node and node number 7 is the second
temperature node to be referenced for temperature-dependent microfunction arguments, and that a scale
factor of 23.174 is to be applied to the QMACROfunction.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 327
Boundary Conditions
Parameter Description
NODE Node number to which the macrofunction heat source is assigned.
MICRO_COUNT Number of microfunctions that will be used to construct the macrofunction.
NODE1 Node number of the temperature that will be used as the T[1] independent
variable for the microfunctions, assuming the specified temperature on the
microfunction input data as the independent variable. See Microfunction Data,
322. If any microfunctions are defined to be functions of D temperature or to be
functions of a radiation potential difference (see MFID, Independent Variable,
and Function Type, 323), NODE1 will correspond to T[1] when QTRAN
computes the DT, radiation potential difference, or Tbar. If no microfunctions use
temperature, D temperature, a radiation potential difference or Tbar as an
independent variable, a 0 may be entered for NODE1. A 0 value for NODE1 will
cause QTRAN to substitute the value of NODE for NODE1.
NODE2 Node number corresponding to T[2] of the microfunction arguments if using D
T, a radiation potential difference, or Tbar as the independent variable for a
microfunction. If no microfunctions use D T, radiation potential differences, or
Tbar, a 0 may be entered for NODE2. A 0 value for NODE2 will cause QTRAN
to substitute the value of NODE for NODE2.
FACTOR A scaling factor for the macrofunction. The value for the macrofunction will be
scaled by multiplying it by FACTOR.
Example
1 5 7
The example declares that MFIDs 1, 5, and 7 will be used to form the QMACROfunction. The
QMACROfunction will have already declared that there will be (3) MFIDs to read.
Parameter Description
MFID(1...n) Identification numbers (MFIDs) of the microfunctions that will be used to form
the macrofunction. See Microfunction Data, 322. All microfunctions given will be
multiplied and the product, scaled by factor, will be used as the macrofunction
input. No keyword precedes the MFID numbers.
Main Index
328 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
1. Enter all data for the macrofunction. See Temperature Control Macrofunction Data, 328. This
information identifies the node number of the macrofunction temperature control input, the
number of microfunctions that make up the arithmetic string, and the node number(s) whose
temperature is to be used as the independent variable for any of the microfunctions that are
temperature dependent.
2. Enter all data for the macrofunction. Construction of the Macrofunction from Microfunctions, 329.
This information identifies which microfunctions are to be combined arithmetically to form the
macrofunction.
3. When all of the temperature control macrofunctions have been defined, enter a dollar sign ($) in
column 1 of the input data file and proceed to Mass Flow Rate Control Macrofunctions, 329. To
define more temperature control macrofunctions, return to Step 1 of this procedure and continue
until all temperature control macrofunctions have been defined.
As many temperature control macrofunctions as desired may be assigned to any node. If more than one
macrofunction is assigned to a node, the node receives the summed output of the macrofunctions. It is
allowed to effectively add or multiply microfunctions to arrive at the desired temperature control
functional form because a macrofunction consists of microfunctions that are multiplied (or divided)
together. Division is also possible because microfunctions can be defined as the reciprocal of any option
contained in the Microfunction Library (Ch. 10), by placing a negative sign in front of the specified option.
Microfunctions can also be effectively used as arguments of other microfunctions to specify any nodal
temperature as the argument for the temperature-dependent microfunctions of a macrofunction, and to
specify nodal temperatures themselves by using temperature control macrofunctions.
Note: This data is normally generated with PATQ menu pick 2 and placed in the file
TMACRODAT.
Example
TMACRO 1 2 1 7 23.174
The example declares that a TMACROfunction data set is being assigned to node 1, is built from 2
microfunctions, that node number 1 is the first temperature node and node number 7 is the second
temperature node to be referenced for temperature-dependent microfunction arguments, and that a scale
factor of 23.174 is to be applied to the TMACROfunction.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 329
Boundary Conditions
Parameter Description
NODE Node number that the macrofunction will control.
MICRO_COUNT Number of microfunctions that will be used to construct the macrofunction.
NODE1 Node number of the temperature that will be used as the T[1] independent
variable for the microfunctions, assuming that the specified temperature is
independent for one or more of the microfunctions used for this macrofunction.
See Microfunction Data, 322. If any microfunctions are defined to be functions of
DT, radiation potential difference or Tbar (see MFID, Independent Variable, and
Function Type, 323, NODE1 will correspond to T[1] when QTRAN computes the
DT or radiation potential difference. If no microfunctions use temperature, DT or
a radiation potential difference as an independent variable, a 0 may be entered for
NODE1. A 0 entered for NODE 1 will cause QTRAN to use NODE for NODE1.
NODE2 Node number corresponding to T[2] if you wish to use D T, a radiation potential
difference, or Tbar as the independent variable for a microfunction. If no
microfunctions use temperatures as arguments, a 0 may be entered for NODE2.
A 0 entered for NODE2 will cause QTRAN to use NODE for NODE2.
FACTOR A scaling factor for the macrofunction. The value for the macrofunction will be
scaled by multiplying it by FACTOR.
codeindent10
1 5 7
The example declares that MFIDs 1, 5, and 7 will be used to form the TMACROfunction. The
TMACROfunction that uses this data will have had the MICRO_COUNT variable given as 3.
.
Parameter Description
MFID(1...n) Identification numbers (MFIDs) of the microfunctions that will be used to form
the temperature control macrofunction. See Microfunction Data, 322. All
microfunctions given will be multiplied and the product, scaled by FACTOR, will
be used as the macrofunction input.
Main Index
330 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
1. Enter all data for the macrofunction. See Mass Flow Rate Control Macrofunction Data, 330. This
information identifies the node number of the macrofunction mass flow rate control input, the
number of microfunctions that make up the arithmetic string, and the node number(s) whose
pressure is to be used as the independent variable for any of the microfunctions that are pressure
dependent.
2. Enter all data for the macrofunction. See Construction of the Macrofunction from Microfunctions,
331. This information identifies which microfunctions are to be combined arithmetically to form
the macrofunction.
3. When all of the mass flow rate control macrofunctions have been defined, enter a dollar sign ($)
in column 1 of the input data file and proceed to Pressure Control Macrofunctions, 331. To define
more mass flow rate control macrofunctions, return to Step 1 of this procedure and continue until
all mass flow rate control macrofunctions have been defined.
As many mass flow rate control macrofunctions as desired may be assigned to any node. If more than
one macrofunction is assigned to a node, the node receives the summed output of the macrofunctions. It
is allowed to effectively add or multiply microfunctions to arrive at the desired mass flow rate control
functional form because a macrofunction consists of microfunctions that are multiplied (or divided)
together. Division is also possible because microfunctions can be defined as the reciprocal of any option
contained in the Function Library in Section 6.2 by placing a negative sign in front of the specified
option. Microfunctions can also be effectively used as arguments of other microfunctions to specify as
the argument for the pressure-dependent microfunctions of a macrofunction, and to specify nodal
temperatures themselves by using temperature control macrofunctions.
Note: This data is normally generated with PATQ menu pick 2 and placed in the file
MMACRODAT.
Example
MMACRO 1 2 1 7 23.174
The example declares that a MMACROfunction data set is being assigned to node 1, is built from 2
microfunctions, that node number 1 is the first pressure node and node number 7 is the second pressure
node to be referenced for pressure dependent microfunction arguments, and that a scale factor of 23.174
is to be applied to the MMACROfunction
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 331
Boundary Conditions
Parameter Description
NODE Node number that the macrofunction will control.
MICRO_COUNT Number of microfunctions that will be used to construct the macrofunction.
NODE1 Node number of the pressure that will be used as the P[1] independent variable
for the microfunctions, assuming the specified pressure is independent for one or
more of the microfunctions used for this macrofunction. See Microfunction Data,
322. If any microfunctions are defined to be functions of DP or Pbar (see MFID,
Independent Variable, and Function Type, 323), NODE1 will correspond to P[1]
when QTRAN computes the DP. If no microfunctions use pressure or DP, a 0 may
be entered for NODE1. A 0 entered for NODE1 will cause QTRAN to use NODE
for NODE1.
NODE2 Node number corresponding to P[2] if D P or Pbar is used as the independent
variable for a microfunction. If no microfunctions use pressures as arguments, a
0 may be entered for NODE2. A 0 entered for NODE2 will cause QTRAN to use
NODE for NODE2.
FACTOR A scaling factor for the macrofunction. The value for the macrofunction will be
scaled by multiplying it by FACTOR.
Example
1 5 7
The example declares that MFIDs 1, 5, and 7 will be used to form the MMACROfunction. The
MMACROfunction that uses this data will have had the MICRO_COUNT variable given as 3.
.
Parameter Description
MFID(1...n) Identification numbers (MFIDs) of the microfunctions that will be used to form
the mass flow rate control macrofunction. See Microfunction Data, 322. All
microfunctions given will be multiplied and the product, scaled by FACTOR, will
be used as the macrofunction input.
Main Index
332 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
2. Enter all data for the macrofunction. See Construction of the Macrofunction from Microfunctions,
333. This information identifies which microfunctions are to be combined arithmetically to form
the macrofunction.
3. When all pressure control macrofunctions are defined, enter a dollar sign ($) in column one of the
input data file and proceed to Initially Fixed Nodes, 333. To define more pressure control
macrofunctions, return to Step 1 of this procedure and continue until all pressure control
macrofunctions have been defined.
As many pressure control macrofunctions as desired may be assigned to any node. If more than one
macrofunction is assigned to a node, the node receives the summed output of the macrofunctions. This
allows the user to add or multiply microfunctions to arrive at the desired pressure control functional form
because a macrofunction consists of microfunctions that are multiplied (or divided) together. Division
is also possible because microfunctions can be defined as the reciprocal of any option contained in the
Microfunction Library (Ch. 10) by placing a negative sign in front of the specified option. Microfunctions
can also be effectively used as arguments of other microfunctions to specify any nodal pressure as the
argument for the pressure-dependent microfunctions of a macrofunction, and to specify nodal pressures
themselves by using pressure control macrofunctions.
Note: This data is normally generated with PATQ menu pick two and placed in the file
PMACRODAT.
Example
PMACRO 1 2 1 7 23.174
The example declares that a PMACROfunction data set is being assigned to node 1, is built from 2
microfunctions, that node number 1 is the first pressure node and node number 7 is the second pressure
node to be referenced for pressure dependent microfunction arguments, and that a scale factor of 23.174
is to be applied to the PMACROfunction.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 333
Boundary Conditions
Parameter Description
NODE Node number that the macrofunction will control.
MICRO_COUNT Number of microfunctions that will be used to construct the macrofunction.
NODE1 Node number of the pressure that will be used as the P[1] independent variable
for the microfunctions, assuming the specified pressure is independent for one or
more of the microfunctions used for this macrofunction. See Microfunction Data,
322. If any microfunctions are defined to be functions of DP or Pbar (see MFID,
Independent Variable, and Function Type, 323), NODE1 will correspond to P[1]
when QTRAN computes the DP. If no microfunctions use pressure or DP, a 0 may
be entered for NODE1. A 0 entered for NODE1 will cause QTRAN to use NODE
for NODE1.
NODE2 Node number corresponding to P[2] if D P or Pbar is used as the independent
variable for a microfunction. If no microfunctions use pressures as arguments, a
0 may be entered for NODE2. A 0 entered for NODE2 will cause QTRAN to use
NODE for NODE2.
FACTOR A scaling factor for the macrofunction. The value for the macrofunction will be
scaled by multiplying it by FACTOR.
Example
1 5 7
The example declares that MFIDs 1, 5, and 7 will be used to form the PMACROfunction. The
PMACROfunction that uses this data will have had the MICRO_COUNT variable given as 3.
Parameter Description
MFID(1...n) Identification numbers (MFIDs) of the microfunctions that will be used to form
the pressure control macrofunction. See Microfunction Data, 322. All
microfunctions given will be multiplied and the product, scaled by FACTOR, will
be used as the macrofunction input.
Main Index
334 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
Important:This data is normally generated from PATQ menu pick two and placed in the file
TFIXDAT for fixed temperature nodes and PFIXDAT for fixed pressure nodes.
Example
TFIX 1001
The example declares that node 1001 is a fixed node.
Parameter Description
TFIX Temperature node being designated as fixed.
Example
PFIX 222
PFIX 1001
The example declares that node 222 and 1001 are fixed pressure nodes. The same node can be fixed in
both temperature and pressure. The assignment of fixed temperatures and pressures is problem-
dependent and one has no requirements imposed on the other.
Parameter Description
PFIX Pressure node being designated as fixed.
Example
CFIX 1 23.7 2
The example declares that node 1 will change classification at time 23.7 from whatever it was to CLASS
= 2, TMACRO function controlled.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 335
Boundary Conditions
Parameter Description
NODE Node number to which the classification change is to be made.
TIME Time at which the classification change is to occur.
CLASS New classification value that will be assigned to node NODE at time TIME.
Allowed CLASS values are described below.
Notice: This data is not generated by Patran or PATQ. Use the system editor to
generate this data. Normally, this data is inserted directly into the QINDAT file.
PINITL(keyword) PINITL
MGLOBL(keyword) MGLOBL
QGLOBL(keyword) QGLOBL
This section allows the system’s initial temperatures pressures, mass flow rate and/or heat sources to be
globally initialized for convenience only. Assign individual initial nodal temperatures (p. 337) and
Main Index
336 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
individual constant nodal heat sources in (p. 338). Note that temperature control macrofunctions (Material
Properties, 263) will normally override the TINITL data. Exceptions to this override are listed as follows:
1. The node is declared to be fixed (see Initially Fixed Nodes, 333. In this case, the value given by
TINITL will be assigned to the node until such time as the node’s classification is changed via
Nodal Classification Changes, 334.
2. The node has its classification changed (see Nodal Classification Changes, 334 prior to the start
of the simulation so that the node is fixed (class = 1) or free (class = 0) instead of macrofunction
controlled (class = 2).
Examples
TINITL 247.5 Kelvin
PINITL 101325.0
QGLOBL 0.0
The example assigns a global initial temperature of 247.5 Kelvin to all nodes, an initial pressure of all
hydraulic nodes of 101325.0, and a global per-unit-volume heat source to all nodes of 0.0.
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 337
Boundary Conditions
Parameter Description
TINITL Initial temperature that is globally assigned to all nodes in the system. To define
initial temperatures that vary from node to node, see Individual Assignments of
Initial Temperatures and Pressures, 337.
TSCALE Temperature scale code R, F, C, K, or blank that specifies what units TINITL is
in. If blank, TINITL is assumed to be in the same temperature scale that you
specified in Temperature Scale and Time Units Definition, 230 for ICCALC.
TSCALE is entered on the same data line as TINITL, following TINITL. Only
the first letter of TSCALE is significant.
PINITL Globally assigns an initial pressure PINITL to all the flow network nodes.
MPI DGH Gravity Head material property ID which is used to define a variable gravity
head.
MPIDGX Material property ID which defines the variable gravity field that is aligned with
the x-global axis.
MPIDGY Material property ID which defines the variable gravity field that is aligned with
the y-global axis.
MPIDGZ Material property ID which defines the variable gravity field that is aligned with
the z-global axis.
MGLOBL A globally assigned mass flow rate for the hydraulic network. The mass flow rate
is calculated for the network; however, if an initial estimate of the mass flow rate
is available, it should be input to speed the rate of convergence.
QGLOBL A globally applied constant heat source. This heat source will be applied to every
node in the system on a per-unit-volume basis, and is additive to any
macrofunction defined heat sources that you will define in Heat Source/Sink
Macrofunction Definition, 325. The value entered for QGLOBL will be multiplied
by the volume entered for each nodal capacitance that will be entered in Thermal
Resistor Assignments, 276 (via 1-D automatic mesh generation) or Capacitor
Data, 320 (capacitors) and this product will be used as a nodal heat source
contribution.
Main Index
338 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
This section allows initial temperatures or pressures to be assigned for individual system nodes
dependent on the keyword. Specify the node number NODE and the initial temperature of the node
TEMP as an ordered pair for each node until all nodes have been entered. If the TSCALE parameter is
not included, the temperature is assumed to be in the units of ICCALC. Pressures are input as a data pair
of node number and pressure with the keyword PRESS. When the data entry for this section has been
completed, enter a dollar sign ($) in Column 1 and proceed to Individual Assignments of Constant Nodal
Heat Sources and Mass Flow Rates, 338.
Important:This data is normally generated by PATQ via menu pick 2 and placed in the file TEMPDAT
for temperature assignments and PRESSDAT for pressure assignments.
Example
TEMP 157 1443.7 Rankine
PRESS 344 17.43
The example assigns a temperature of 1443.7 Rankine to node number 157. A pressure of 17.43 was
assigned to node 344.
Parameter Description
NODE Node number whose temperature is to be initialized.
TEMP Initial temperature being assigned for node number NODE.
TSCALE Temperature scale code R, F, C, K, or blank for TEMP. If blank, TEMP is
assumed to be in the units specified by ICCALC. See Temperature Scale and
Time Units Definition, 230. Only the first character of TSCALE is significant.
NODE Node number whose pressure is to be initialized.
PRESS Initial pressure being assigned for node number NODE.
This section allows constant heat sources to be assigned to individual system nodes or mass flow rates to
individual hydraulic nodes. Specify the node number NODE and the constant heat source value
QVALUE or mass flow rate MDVALUE for the node as an ordered pair for each node depending on the
keyword until all such constant nodal data has been entered. When data entry for this section has been
completed, enter a dollar sign ($) in column one and the input data file is finished. Please note that this
section is used only for CONSTANT nodal heat sources. The heat sources applied by this section cannot
Main Index
Chapter 8: Thermal/Hydraulic Input Deck 339
Boundary Conditions
be changed or modified in any way by any other control parameters in the program (although they could
be modified by user-supplied subroutines). The heat source macrofunctions should normally be used for
variable heat sources. See Heat Source/Sink Macrofunction Definition, 325. For cases where constant
nodal heat sources are appropriate, this section is less cumbersome to use than the heat source
macrofunction section, and the CPU requirements are substantially less for this section's data. Heat
sources are additive with any QMACRO function and QGLOBL heat sources that may have been applied
to the same nodes.
Important:If more than one QBASE or MDBASE value is assigned to a node, the values are
summed.This data is normally generated by PATQ via menu pick two and placed in the file
QBASEDAT for heat source assignments and MDBASEDAT for mass flow rate
assignments.
Example
QBASE 15 1443.7
MDBASE 20 0.07
The example assigns a constant heat source of 1443.7 to node number 15 and assigns a constant mass
flow rate of 0.07 to node 20.
.
Parameter Description
NODE Node number which has a constant heat source applied.
QVALUE The constant heat source value.
NODE Node number which has a constant mass flow rate applied.
MDVALUE The constant mass flow rate. Remember that specific weight is used to define
flow rates and internal units conversions are performed for the English system of
units.
Main Index
340 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Boundary Conditions
Main Index
Chapter 9: Convection Library
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
9 Convection Library
Main Index
342 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Convection Configurations
This section is a catalogue of various convection configurations that are available in the QTRAN
program. A configuration is defined here to be a given class of convection correlations and not to be
confused with Patran element configuration codes. For example, forced convection over flat plates would
be one configuration, while natural convection for horizontal cylinders would be another configuration.
There are 31 specific configurations and 6 generic configurations currently in the QTRAN library. There
are 61 separate convection correlations that are used to support these configurations. When selecting a
configuration that is applicable to a given convective resistor, QTRAN automatically selects the
appropriate convection correlation for the calculated parameter range (e.g., Rayleigh number ranges,
Reynolds number ranges, Prandtl number ranges). If no correlation is available for the calculated
parameter range, QTRAN will select the most suitable correlation and print a warning message in the
QOUTDAT file. In most cases, QTRAN will not terminate execution. However, for some correlations,
such as inclined plates, an erroneous plate angle will cause program termination and an error message.
Configurations are selected by specifying the configuration number for the CFIG data entry. See
Convective Resistor Header Data (Ch. 8).
Most convective resistors will have only two nodes. However, some special resistors (e.g., flow through
tubes) require three nodes (i.e., an upstream or entrance node, a downstream or exit node, and a wall
node). These are listed explicitly as node numbers in the configuration description.
There are two classes of properties used as input for the convective resistors. The first class of properties
are geometric properties (GP). These are properties which are not allowed to be temperature-dependent,
and in general are properties such as characteristic lengths, areas, and inclination angles. However, other
properties such as gravitational constants are also defined to be GP properties.
MPID numbers (see MPID Number, Function Type, Temperature Scale, Factor and Label (Ch. 8)) must
be specified for the MPID data entry. See Convective Resistor Material Properties (Ch. 8). The MPID
values identify which material properties are to be used for the resistor.
The convection Loads/BC is explained in Loads and Boundary Conditions Form, 105. The CONV
template format (in the TEMPLATEDAT file) which associates the TID specified in the convection LBC,
with the convection configuration (CFIG), geometric properties (GPs) and appropriate MPIDs is
discussed in CONV Templates, 690.
Convection correlations are listed with each convective configuration. References for each correlation's
source material are provided at the beginning of each correlation's entry.
The following parameter definitions apply to the convection correlations supplied for each convective
configuration. More parameter definitions are available with some of the correlations. A listing of the
available convection configurations is given below:
Main Index
Chapter 9: Convection Library 343
Convection Configurations
Configuration Description
1 Forced Convection, Smooth Isothermal Tubes
2 Smooth Tubes, Constant Heat Flux, Forced Convection
3 Flat Plates, Forced Convection
4 Circular Tube in Cross Flow, Forced Convection
5 Square Tube in Cross Flow, Stagnation Point at Tube Corner, Gas Only, Forced
Convection
6 Square Tube, Cross Flow, Stagnation Point at Mid-Side, Gas Only, Forced
Convection
7 Hexagonal Tube, Cross Flow, Stagnation Point at Edge, Gas Only, Forced
Convection
8 Hexagonal Tube, Cross Flow, Stagnation Point at Mid-Side, Gas Only, Forced
Convection
9 Vertical Plate in Horizontal Flow, Gas Only, Forced Convection
10 Flow Around a Sphere, Gas Only, Forced Convection
11 Flow Around a Sphere, Oil and Water Only, Forced Convection
12 Staggered Tube Banks Consisting of Ten or More Rows, Single Phase Flow,
Forced Convection
13 Isothermal Vertical, Horizontal, or Inclined Flat Plates, Natural Convection
14 Rectangular Blocks, Natural Convection
15 Horizontal Cylinders, Natural Convection
16 Sphere, Natural Convection
17 Enclosed Spaces Between Flat Plates, Natural Convection
18 Annular Space Between Concentric Spheres, Natural Convection
19 Vertical or Inclined Surface, Uniform Heat Flux, Natural Convection
20 Vertical Enclosed Space, Uniform Heat Flux, Natural Convection
21 Combined Natural and Forced Convection in Horizontal Tubes
22 Filmwise Condensation on a Vertical Surface
23 Filmwise Condensation on a Horizontal Tube
24 Pool Boiling
25 Forced Convection Through Packed Beds
26 Generic Natural Convection, H=H(TDIFF)
27 Generic Natural Convection, H=H(Gr, Pr)
28 Generic Forced Convection
29 Generic H Value, H = H(TBAR) or H(time)
Main Index
344 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration Description
30 Generic H Value, H = H(TDIFF)
31 Constant H Value
32 Rotating Disk
33 Forced Convection, Smooth Isothermal Tubes
34 Smooth Tubes, Constant Heat Flux, Turbulent Flow, Forced Convection
35 Combined Natural and Forced Convection in Horizontal Tubes
36 Forced Convection Through Packed Beds
37 Contact Resistance with an Interstitial Fluid
38 Generic Forced Convection with Variable Velocity
39 Correlation 63 Generic H Value, H = H(Tb) * GP(2)
40 Generic H Value, H = H(Tb) * GP - Ignore Area
41 Generic Forced Convection with Viscosity Correction
42 Generic Forced Convection with Temperature Correction
43 Local Flat Plate Heating, Forced Convection
44-999 Reserved (not currently used)
1000+ User Supplied
Parameter Definitions
Table 9-1 Symbols
Main Index
Chapter 9: Convection Library 345
Convection Configurations
A = ratio of bed surface area to bed volume. See Correlation 52 Forced Convection
Through a Packed Bed (Ref. 8 in Appendix A), 407 and Correlation 53 Forced
Convection Through a Packed Bed (Ref. 8 in Appendix A), 408.
a = k
diffusivity, --------
-
ρc p
As = surface area.
Cp = constant pressure specific heat.
CSF = experimental constant for Correlation 50 Filmwise Condensation on Horizontal Tube
(Ref. 6 in Appendix A), 403. See Ref. 6 in Appendix A.
D = diameter.
EPSI = fluid/tube void fraction for Correlation 21 Vertical Plate in Horizontal Flow, Forced
Convection (Ref. 6 in Appendix A), 366. See Ref. 6 in Appendix A.
g = gravitational constant.
Go = mass flux. See Correlation 52 Forced Convection Through a Packed Bed (Ref. 8 in
Appendix A), 407 and Correlation 53 Forced Convection Through a Packed Bed
(Ref. 8 in Appendix A), 408.
Gr = 3
( Tw – T∞ )ρ
2
Grashof number, gβL
-----------------------------------------------
2
μ
Gz =
Graetz number, ( Re ) ( Pr ) ⎛⎝ D
----⎞
⎠ L
( ΔT o – ΔT L )
-------------------------------
-
ΔT o
l ⎛ ----------⎞
⎝ ΔT L⎠
( T3 – T2 )
-------------------------
-
T1 T2
l ⎛ ------------------⎞
⎝ T 1 – T 3⎠
Main Index
346 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
μf = viscosity of liquid.
Nu = Nusselt Number, hD
-------
k
f = angle, in radians.
Pr = C μ
p
Prandtl number, ---------
-
k
y = particle shape factor. See Correlation 52 Forced Convection Through a Packed Bed
(Ref. 8 in Appendix A), 407 and Correlation 53 Forced Convection Through a Packed
Bed (Ref. 8 in Appendix A), 408.
Ra = Rayleigh number, Gr Pr.
Re = Reynolds number, ρVD
------------
μ
ρv = density of liquid.
ρv = density of vapor.
Main Index
Chapter 9: Convection Library 347
Convection Configurations
Configuration 1
Forced Convection, Smooth Isothermal Tubes
Node Number 1 = tube/element inside wall temperature, T 1 .
2 = fluid entrance temperature, T 2 .
3 = fluid exit temperature, T 3 .
GP* 1 = tube/element inside surface area, A s .
2 = distance from upstream tube/element section to the tube inlet, x=L i .
3 = distance from downstream tube/element section to the tube inlet, x=L f .
4 = tube/element inside diameter, D i .
5 = ·
average fluid velocity, v .
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c P .
4 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
.
Figure 9-1
Main Index
348 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 1
Smooth Tubes, Fully Developed Turbulent Flow (Ref. 6 in Appendix A)
(Used for heating the fluid)
μ
0.08 < -------- < 40.0
μw
Evaluate properties at arithmetic mean bulk temperature, except for μ W which is evaluated at the wall
temperature. Use LMTD for calculation of “Q”.
1.0
F = ------------------------------------------------------------------
2
( 1.82 * log 10 ( Re ) – 1.64 )
F8 = F
---
8
μ 0.11
H = ⎛ -----⎞ ----------------------------------------------------------------------------------------
- ⎛ ------⎞
k F8 * Re * Pr
⎝ D i⎠ 2⁄3 ⎝ μ w⎠
1.07 + 12.7 * F8 * ( Pr – 1.0 )
Q = H * A s * LMTD
Correlation 2
Smooth Isothermal Tubes, Turbulent Flow (Ref. 6 in Appendix A)
(Used for cooling the fluid)
μ
0.08 < ------ < 40.0
μw
·
2.0 < Pr < 140.0
Evaluate properties at arithmetic mean bulk temperature, except for μw which is evaluated at the wall
temperature. Use LMTD for calculation of “Q”.
1.0
F = ------------------------------------------------------------------
2
( 1.82 * log 10 ( Re ) – 1.64 )
F
F8 = ---
8
μ 0.25
H = ⎛ -----⎞ ----------------------------------------------------------------------------------------
- ⎛ ------⎞
k F8 * Re * Pr
⎝ D i⎠ 2⁄3 ⎝ μ w⎠
1.07 + 12.7 * F8 * ( Pr – 1.0 )
Q = H * A s * LMTD
Main Index
Chapter 9: Convection Library 349
Convection Configurations
Correlation 3
Smooth Isothermal Tubes, Laminar Flow (Ref. 6 in Appendix A)
Re < 2000
Evaluate properties at arithmetic mean bulk temperature. Use LMTD to calculate “Q”.
D
3.66 + 0.0668 * ---- * Re * Pr
H = ⎛ -----⎞ -----------------------------------------------------------------------------
k L
-
⎝ D i⎠ 2⁄3
1.0 + 0.04 * ---- * Re * Pr⎞ ⎛ D
⎝L ⎠
Q = H * A s * LMTD
Correlation 4
Liquid Metals, Smooth Tubes, Turbulent Flow (Ref. 6 in Appendix A)
(Re * Pr) > 1000
Q = H * A s * LMTD
Correlation 5
Smooth Isothermal Tubes, Turbulent Flow (Ref. 6 in Appendix A)
This equation will be used when other smooth tube, constant wall temperature correlations are out of their
respective Pr and tl number ranges (i.e., 0.05 < Pr < 2.0).
Evaluate properties at mean bulk temperature, with the exception of the wall viscosity. Use LMTD to
calculate “Q”.
1 ⁄ 3 ⎛ μ ⎞ 0.14
H = 0.027 * ⎛ -----⎞ Re
k 0.8
* Pr ⎝ μ ------
⎝ D i⎠ w
⎠
Q = H * A s * LMTD
Transitional Region
For Reynolds numbers between 2000 and 5000, a linear interpolation between the laminar and turbulent
functions is used.
Main Index
350 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 2
Smooth Tubes, Constant Heat Flux, Forced Convection
Node Number 1 = tube/element inside wall temperature, T 1 .
2 = fluid entrance temperature, T 2 .
3 = fluid exit temperature, T 3 .
GP* 1 = tube/element inside surface area, A s .
2 = distance from upstream tube/element section to the tube inlet, x=L i .
3 = distance from downstream tube/element section to the tube inlet, x=L f .
4 = tube/element inside diameter, D i .
5 =
average fluid velocity, v.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c p .
4 = fluid thermal conductivity, k.
Main Index
Chapter 9: Convection Library 351
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-2
Correlation 6
Liquid Metals, Smooth Tubes, Turbulent Flow, Constant Heat Flux (Ref. 6 in Appendix A)
3.6E + 03 < Re < 9.05E + 05
Q = H * A s * LMTD
Correlation 7
Smooth Tubes, Turbulent Flow, Constant Heat Flux (Ref. 6 in Appendix A)
(2300 < Re)
Evaluate properties at arithmetic mean bulk temperature. Use LMTD to calculate “Q”.
1.0
F = ------------------------------------------------------------------
2
( 1.82 * log 10 ( Re ) – 1.64 )
F8 = F
---
8
Main Index
352 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
H = ⎛ -----⎞ ----------------------------------------------------------------------------------------
k F8 * Re * Pr
-
⎝ D i⎠ 2⁄3
1.07 + 12.7 * F8 * ( Pr – 1.0 )
Q = H * A s * LMTD
Correlation 8
Smooth Tubes, Laminar Flow, Constant Heat Flux (Rohsenow & Hartnett, Handbook of Heat
Transfer)
(Re < 2300)
Properties are evaluated at arithmetic mean bulk temperature. The h value returned will be an integrated
average of the H values along the tube length. Four sample points will be taken, and an averaging scheme
analogous to Simpson’s 3/8ths rule for integration will then be used. Use the LMTD to calculate “Q”.
X1 is the distance between the upstream end of the tube section and the tube entrance. X2 is the distance
between the downstream end of the tube section and the tube entrance. DXP is one third the length of the
tube section being modeled.
( X2 – X1 )
DXP = --------------------------
3.0
Compute the x-value distances at four sample points. For consistency, the 4 “X” values will be stored in
“XPLUS” variables, i.e. (XPLUS1, XPLUS2, XPLUS3, and XPLUS4). XPLUS1 will be the distance
between the tube entrance and the upstream end of the tube section. XPLUS4 is the distance between the
tube entrance and the downstream end of this tube section. XPLUS2 and XPLUS3 are spaced evenly so
as to divide the tube section being modeled into thirds. Subroutine NUSLT8 will then convert these
distances into the XPLUS values as used in Rohsenow and Hartnett.
XPLUS1 = X1
XPLUS4 = X2
XPLUS2 = XPLUS1 + DXP
XPLUS3 = XPLUS2 + DXP
Compute the h values at the (4) sample points along the tube length.
CALL NUSLT8(H1, K, D, XPLUS1, Re, Pr)
CALL NUSLT8(H2, K, D, XPLUS2, Re, Pr)
CALL NUSLT8(H3, K, D, XPLUS3, Re, Pr)
CALL NUSLT8(H4, K, D, XPLUS4, Re, Pr)
Use a weighted average of the H values along the tube length. The weighting scheme is that used for
Simpson’s 3/8ths rule for integrating ordinary differential equations.
H=(H1+3.0*(H2+H3+H4)*0.125
Main Index
Chapter 9: Convection Library 353
Convection Configurations
Configuration 3
Flat Plates, Forced Convection
Main Index
354 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-3
Correlation 9
Flat Plate Forced Convection, Laminar Flow (Ref. 6 in Appendix A)
Reynolds number is based on plate length. Use T WALL – T FLUID to calculate “Q”.
Main Index
Chapter 9: Convection Library 355
Convection Configurations
H = ⎛ ---⎞ 0.664 * Re * Pr
k 1⁄3
⎝ L⎠
Q = H * A s *B(T w – T f )
Correlation 10
Flat Plate Forced Convection, Turbulent Flow (Ref. 6 in Appendix A)
2.0E+05 < Re < 5.5E+6
0.7 < Pr < 380.0
μ
0.26 < ------ < 3.5
μw
Use for “small” temperature differences. Reynolds number is based on plate length. Use T WALL – T FLUID
to calculate “Q”. Properties are calculated at free stream temperature.
H = ⎛ ---⎞ ( 0.036 * ( Re * Pr
k 0.8 0.43 1⁄3
– 17400.0 ) + 297.0 * Pr )
⎝ L⎠
Q = H * A s *B(T w – T f )
Main Index
356 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 4
Circular Tube in Cross Flow, Forced Convection
Node Number 1 = tube outside wall temperature, T 1 .
2 = fluid free-stream temperature, T 2 .
GP* 1 = tube/outside surface area, A s .
2 = tube/outside diameter, D.
3 =
fluid free-stream velocity, v.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c p .
4 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-4
Correlation 11
Circular Tube in Cross Flow, Forced Convection (Ref. 6 in Appendix A)
0.4 < Re < 4.0)
Reynolds number based upon tube diameter. Used for both gases and liquids.
Main Index
Chapter 9: Convection Library 357
Convection Configurations
H = ⎛ ----⎞ 0.989 * Re
k 0.33 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 12
Circular Tube in Cross Flow, Forced Convection (Ref. 6 in Appendix A)
4.0 < Re < 40.0)
Reynolds number based upon tube diameter. All properties based upon film temperature unless otherwise
noted. Used for both gases and liquids.
H = ⎛ ----⎞ 0.911 * Re
k 0.385 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 13
Circular Tube in Cross Flow, Forced Convection (Ref. 6 in Appendix A)
40.0 < Re < 4000.0)
Reynolds number based upon tube diameter. All properties based upon film temperature unless otherwise
noted. Used for both gases and liquids.
H = ⎛ ----⎞ 0.683 * Re
k 0.486 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 14
Circular Tube in Cross Flow, Forced Convection (Ref. 6 in Appendix A)
( 4000.0 < Re < 40,000.0 )
Reynolds number based upon tube diameter. All properties based upon film temperature unless otherwise
noted. Used for both gases and liquids.
H = ⎛ ----⎞ 0.193 * Re
k 0.618 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 15
Circular Tube in Cross Flow, Forced Convection (Ref. 6 in Appendix A)
(4.0E+04< Re < 4.0E+05)
Reynolds number based upon tube diameter. All properties based upon film temperature unless otherwise
noted. Used for both gases and liquids.
H = ⎛ ----⎞ 0.0266 * Re
k 0.805 1⁄3
* Pr
⎝ D⎠
Main Index
358 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Q = H * A s * (T w – T f )
Configuration 5
Square Tube in Cross Flow, Stagnation Point at Tube Corner, Gas Only, Forced
Convection
Node Number 1 = tube outside wall temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = tubes outside surface area, A s .
2 = length of square tube's diagonal, D.
3 =
gas free-stream velocity, v.
MPID 1 = gas density, ρ .
2 = gas absolute viscosity, μ .
3 = gas specific heat, c p .
4 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-5
Main Index
Chapter 9: Convection Library 359
Convection Configurations
Correlation 16
Square Tube in Cross Flow, Stagnation Point at Corner of Tube, Forced Convection (Ref. 6 in
Appendix A)
(5.0E+03 < Re < 1.0E+05)
Reynolds number based on length of square’s diagonal. All properties based upon film temperature
unless otherwise noted. Used for gases only.
H = ⎛ ----⎞ 0.0246 * Re
k 0.588 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Main Index
360 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 6
Square Tube, Cross Flow, Stagnation Point at Mid-Side, Gas Only, Forced Convection
Node Number 1 = tube outside wall temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = tubes outside surface area, A s .
2 = length of one side of tube’s square, D.
3 =
gas free-stream velocity, v.
MPID 1 = gas density, ρ .
2 = gas absolute viscosity, μ .
3 = gas specific heat, c p .
4 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-6
Correlation 17
Square Tube in Cross Flow, Stagnation Point at Mid-Side, Forced Convection
(Ref. 6 in Appendix A)
(5.0E+03 < Re < 1.0E+05)
Main Index
Chapter 9: Convection Library 361
Convection Configurations
Reynolds number based upon length of one side of square. All properties based upon film temperature
unless otherwise noted. Used for gases only.
H = ⎛ ----⎞ 0.102 * Re
k 0.675 1⁄3
* Pr
⎝ D⎠
Q = H * A s * (T w – T f )
Configuration 7
Hexagonal Tube, Cross Flow, Stagnation Point at Edge, Gas Only, Forced Convection
Node Number 1 = tube outside tube wall temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = tubes outside surface area, A s .
2 = distance between parallel sides, L.
3 =
gas free-stream velocity, v.
MPID 1 = gas density, ρ .
2 = gas absolute viscosity, μ .
3 = gas specific heat, c p .
4 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-7
Main Index
362 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 18
Hexagonal Tube in Cross Flow, Stagnation Point at Edge, Forced Convection
(Ref. 6 in Appendix A)
(5.0E+03 < Re < 1.0E+05)
Reynolds number based on distance between parallel sides. All properties based upon film temperature
unless otherwise noted. Used for gases only.
H = ⎛ ---⎞ 0.153 * Re
k 0.638 1⁄3
* Pr
⎝ L⎠
Q = H * A s * (T w – T f )
Main Index
Chapter 9: Convection Library 363
Convection Configurations
Configuration 8
Hexagonal Tube, Cross Flow, Stagnation Point at Mid-Side, Gas Only, Forced
Convection
Node Number 1 = tube outside wall temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = tubes outside surface area, A s .
2 = distance between parallel sides, L.
3 =
gas free-stream velocity, v.
MPID 1 = gas density, ρ .
2 = gas absolute viscosity, μ .
3 = gas specific heat, c p .
4 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-8
Main Index
364 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 19
Hexagonal Tube in Cross Flow, Stagnation Point on One Side, Convection
(Ref. 6 in Appendix A)
(5.0E+03 < Re < 1.95E+04)
Reynolds number based on distance between parallel sides. All properties based upon film temperature
unless otherwise noted. Used for gases only.
H = ⎛ ---⎞ 0.16 * Re
k 0.638 1⁄3
* Pr
⎝ L⎠
Q = H * A s * (T w – T f )
Correlation 20
Hexagonal Tube in Cross Flow, Stagnation Point on One Side, Forced Convection (Ref. 6 in
Appendix A)
(1.95E+04 < Re < 1.0E+05)
Reynolds number based on distance between parallel sides. All properties based upon film temperature
unless otherwise noted. Used for gases only.
H = ⎛ ---⎞ 0.0385 * Re
k 0.782 1⁄3
* Pr
⎝ L⎠
Q = H * A s * (T w – T f )
Main Index
Chapter 9: Convection Library 365
Convection Configurations
Configuration 9
Vertical Plate in Horizontal Flow, Gas Only, Forced Convection
Node Number 1 = plate surface temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = plate/element surface area, A s .
2 = shortest distance from element to plate’s edge, x=L i .
3 = longest distance from element to plate’s edge, x=L f .
4 =
gas free-stream velocity, v.
MPID 1 = gas density, ρ .
2 = gas absolute viscosity, μ .
3 = gas specific heat, c p .
4 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-9
Main Index
366 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 21
Vertical Plate in Horizontal Flow, Forced Convection (Ref. 6 in Appendix A)
(4.0E+03 < Re < 1.5E+04)
Reynolds number based on height of plate. All properties based upon film temperature unless otherwise
noted. Used for gases only.
H = ⎛ ---⎞ 0.228 * Re
k 0.731 1⁄3
* Pr
⎝ L⎠
Q = H * A s * (T w – T f )
Main Index
Chapter 9: Convection Library 367
Convection Configurations
Configuration 10
Flow Around a Sphere, Gas Only, Forced Convection
Node Number 1 = sphere wall temperature, T 1 .
2 = gas free-stream temperature, T 2 .
GP* 1 = sphere’s surface area, A s .
2 = sphere diameter, D o .
3
= gas free-stream velocity, v.
MPID 1 = gas density, . ρ
2 = gas absolute viscosity, μ .
3 = gas thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-10
Correlation 22
Flow Around a Sphere, Forced Convection (Ref. 6 in Appendix A)
(17.0 < Re < 7.0E+05)
Reynolds number based upon sphere diameter. All properties based upon film temperature unless
otherwise noted. Used for gases only.
Main Index
368 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
H = ⎛ ------⎞ 0.37 * Re
k 0.6
⎝ D o⎠
Q = H * A s * (T w – T f )
Configuration 11
Flow Around a Sphere, Oil and Water Only, Forced Convection
Node Number 1 = sphere wall temperature, T 1 .
2 = fluid free-stream temperature, T 2 .
GP* 1 = sphere’s surface area, A s .
2 = sphere diameter, D o .
3 =
fluid free-stream velocity, v.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c p .
4 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-11
Main Index
Chapter 9: Convection Library 369
Convection Configurations
Correlation 23
Flow Around a Sphere, Forced Convection (Ref. 6 in Appendix A)
(1.0 < Re < 2.0E+05)
Reynolds number based upon sphere diameter. All properties based upon film temperature unless
otherwise noted. Used for oil and water only. μw is the viscosity evaluated at the wall temperature.
0.3 μ 0.25
H = ⎛ ------⎞ ( 1.2 + 0.53 * Re ) *Pr ⎛ ------⎞
k 0.54
⎝ D o⎠ ⎝ μ w⎠
Q = H * A s * (T w – T f )
Main Index
370 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 12
Staggered Tube Banks Consisting of Ten or More Rows, Single Phase Flow, Forced
Convection
Node Number 1 = tube wall temperatures, T.
2 = fluid free-stream temperatures, T 2 .
GP* 1 = tube's elements outside surface area, A s .
2 = tube outside diameter, D.
3 =
fluid free-stream velocity, v.
4 = void fraction (area of flow with tubes divided by area of flow without tubes).
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c p .
4 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-12
Main Index
Chapter 9: Convection Library 371
Convection Configurations
Correlation 24
Staggered Tube Banks Consisting of Ten or More Rows, Single Phase Flow, Forced Convection
(Ref. 6 in Appendix A)
100.0 < Re < 1.0E+05
0.7 < Pr < 760.0
μ BULK
0.18 < ---------------- < 4.3
μw
3.0 * ρ * D * ( U average )
Re = ----------------------------------------------------------------------
-
2.0 * μ BULK * ( 1.0 – EPSI )
1 ⁄ 3 μ 0.14
H = ⎛ ----⎞ ( 0.5 * Re + 0.2 * Re ) * Pr ⎛ ------⎞
k 0.5 2⁄3
⎝ D⎠ ⎝ μ w⎠
Q = H * A s * (T w – T f )
Main Index
372 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 13
Isothermal Vertical, Horizontal, or Inclined Flat Plates, Natural Convection
Node Number 1 = plate surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = plate/element's surface area, A s .
2 = for vertical or inclined plates, shortest distance between the plate/element’s
surface area and the plate’s edge where the boundary layer thickness is zero.
For example, on a heated vertical plate exposed to a relatively cooler gas, the
buoyancy driven convective flow will be upward and hence the boundary
layer is of zero thickness at the plate’s bottom edge. You would then enter
the shortest distance between the plate/elements area and the bottom edge of
the plate, ( x=L i ) . For horizontal plates, this value is the surface area divided
by the plate perimeter.
3 = ignored for horizontal plates. For vertical and inclined plates, this is the
longest distance to the plate’s edge where the boundary layer thickness is
zero, x=L f .
4 = plate inclination angle PHI in degrees.
φ = 0 implies the plate is vertical.
φ = 90 implies the plate is horizontal and facing upward.
φ = – 90 implies the plate is horizontal and facing downward.
φ must be between -90 and +90. The only correlation in the library for
inclined plate is for the hot surfaces down or cold surfaces up.
5 =
gravitational constant, g .
Main Index
Chapter 9: Convection Library 373
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-13
Correlation 25
Isothermal Vertical Plates, Natural Convection (Ref. 6 in Appendix A)
Ra < 1.0E+09
Rayleigh number based upon plate height.
All properties based upon film temperature.
⎛ ⎞
k ⎜ 0.25 ⎟
H = ⎛ ---⎞ ⎜ 0.68 + ---------------------------------------------------------
0.670 * Ra
- ⎟
⎝ L⎠ ⎜ 9 ⁄ 16 4 ⁄ 9
⎟
1.0 + ⎛ -------------⎞
0.492
⎝ ⎝ Pr ⎠ ⎠
Q = H * A s * (T w – T f )
Correlation 26
Isothermal Vertical Plates, Natural Convection (Ref. 6 in Appendix A)
1.E+09 < Ra
Rayleigh number based upon plate height.
All properties based upon film temperature.
Main Index
374 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
⎛ ⎞2
⎜ 1⁄6 ⎟
H = ⎛ ---⎞ ⎜ 0.825 + ------------------------------------------------------------⎟
k 0.387 * Ra
⎝ L⎠ ⎜ 9 ⁄ 16 8 ⁄ 27
⎟
1.0 + ⎛ -------------⎞
0.492
⎝ ⎝ Pr ⎠ ⎠
Q = H * A s * (T w – T f )
Correlation 27
Hot Horizontal Plate Facing Upward (or Cold Horizontal Plate Facing Downward), Natural
Convection (Ref. 6 in Appendix A)
2.6E+04 < Ra < 1.0E+07
L = surface area / perimeter
All properties based upon film temperature.
H = ⎛ ---⎞ 0.54 * Ra
k 0.25
⎝ L⎠
Q = H * A s * (T w – T f )
Correlation 28
Hot Horizontal Plate Facing Upward (or Cold Horizontal Plate Facing Downward), Natural
Convection (Ref. 6 in Appendix A)
1.0E+07 < Ra < 3.0E+10
L = surface area / perimeter
All properties based upon film temperature.
H = ⎛ ---⎞ 0.15 * Ra
k 1⁄3
⎝ L⎠
Q = H * A s * (T w – T f )
Correlation 29
Hot Horizontal Plate Facing Downward (or Cold Horizontal Plate Facing Upward), Natural
Convection (Ref. 6 in Appendix A)
3.0E+05 < Ra < 3.0E+10
L = surface area / perimeter
All properties based upon film temperature.
H = ⎛ ---⎞ 0.27 * Ra
k 0.25
⎝ L⎠
Q = H * A s * (T w – T f )
Correlation 30
Inclined Surfaces, Natural Convection (Hot Surface Facing Downward or Cold Surface Facing
Upward) (Ref. 6 in Appendix A)
1.0E+05 < Ra * COS(φ ) < 1.0E+11
Main Index
Chapter 9: Convection Library 375
Convection Configurations
L = plate length
φ = angle of plate inclination from the vertical
All properties based upon film temperature. For laminar regions, use correlations
(Ref. 6 in Appendix A). Extend correlation using the vertical surface correlations
(Ref. 14 in Appendix A).
Note: the first if statement below should be put with the above equation and then everything lined up
and this statement deleted. I don’t know how to do that.
if Ra * cos ( φ ) < 3.1E9
H = ⎛ ---⎞ 0.021 ( Ra * cos ( φ ) )
k 0.4
⎝ L⎠ if Ra * cos ( φ ) ≥ 3.1E9
Q = H * A s * (T w – T f )
Configuration 14
Rectangular Blocks, Natural Convection
Main Index
376 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
LH * LV
L = ----------------------
LH + LV
Figure 9-14
Main Index
Chapter 9: Convection Library 377
Convection Configurations
Correlation 31
Rectangular Blocks, Natural Convection (Ref. 6 in Appendix A)
1.0E+04 < Ra < 1.0E+09
LH * LV
L = ----------------------
LH + LV
= ⎛ ---⎞ * 0.55 * Ra
k 0.25
H
⎝ L⎠
Q = H * A s * (T w – T f )
Main Index
378 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 15
Horizontal Cylinders, Natural Convection
Node Number 1 = cylinder outside surface temperature, T 1 .
2 = fluid free-stream temperature, T 2 .
GP* 1 = cylinder’s outside surface area, A s .
2 =
gravitational constant, g .
Figure 9-15
Correlation 32
Horizontal Cylinders, Natural Convection (Ref. 6 in Appendix A)
1.0E+04 < Ra < 1.0E+09
Main Index
Chapter 9: Convection Library 379
Convection Configurations
D = cylinder diameter
All properties based upon film temperature.
1---
= ⎛ ----⎞ * 0.53 * Ra
k 3
H
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 33
Horizontal Cylinders, Natural Convection (Ref. 6 in Appendix A)
1.0E+09 < Ra < 1.0E+12
D = cylinder diameter
All properties based upon film temperature.
= ⎛ ----⎞ * 0.13 * Ra
k 1⁄3
H
⎝ D⎠
Q = H * A s * (T w – T f )
Main Index
380 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 16
Sphere, Natural Convection
Node Number 1 = sphere surface temperature, T 1 .
2 = fluid free-stream temperature, T 2 .
GP* 1 = sphere’s surface area, A s .
2 =
gravitational constant, g .
3 = sphere diameter, D.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid coefficient of thermal expansion, β .
4 = fluid specific heat, c p .
5 = fluid thermal conductivity, k.
Figure 9-16
Correlation 34
Sphere, Natural Convection (Ref. 6 in Appendix A)
1.0E+00 < Ra < 1.0E+05
D. = sphere diameter
All properties based upon film temperature.
Main Index
Chapter 9: Convection Library 381
Convection Configurations
Q = H * A s * (T w – T f )
Main Index
382 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 17
Enclosed Spaces Between Flat Plates, Natural Convection
Node Number 1 = top plate, low or surface temperature, T 1 .
2 = bottom plate, upper surface temperature, T 2 .
GP* 1 = plate/element’s surface area that is exposed to the enclosed space, A s .
2 = enclosed space inclination angle PHI in degrees.
φ = 0 implies that the enclosed space is horizontal.
Figure 9-17
Main Index
Chapter 9: Convection Library 383
Convection Configurations
Correlation 35
Enclosed Vertical Space, Natural Convection (Ref. 2 in Appendix A)
2.0E+04 < Gr < 2.0E+05
L = plate height
D = space between plates (normal distance)
Gr number based upon D
All properties based upon average of surface temperatures.
T1 – T2
Definition: ----- = Ke * ⎛ ------------------⎞
Q
As ⎝ D ⎠
0.25 ⎛ D⎞ 1 ⁄ 9
Ke = 0.18 * k * Gr ----
⎝ L⎠
Correlation 36
Enclosed Vertical Space, Natural Convection (Ref. 7 in Appendix A)
2.0E+05 < Gr < 1.1E+07
L = plate height
D = space between plates (normal distance)
Gr number based upon D
All properties based upon average of surface temperatures.
T1 – T2
Definition: ----- = Ke * ⎛ ------------------⎞
Q
As ⎝ D ⎠
1 ⁄ 3 ⎛ D⎞ 1 ⁄ 9
Ke = 0.065 * k * Gr ----
⎝ L⎠
Correlation 37
Enclosed Horizontal Space, Natural Convection, Hot Plate on Bottom, Cold Plate on Top, (Ref. 6
in Appendix A)
6.0E+06 < Ra < 1.0E+08
D = space between plates (normal distance)
Ra number based upon D
All properties based upon average of surface temperatures.
T1 – T2
Definition: ----- = Ke * ⎛ ------------------⎞
Q
As ⎝ D ⎠
Ke = ⎛ ----⎞ 0.104 * Ra
k 0.305 0.084
* Pr
⎝ D⎠
Main Index
384 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 38
Enclosed Horizontal Space, Natural Convection, Cold Plate on Bottom, Hot Plate on Top, (Ref. 6
in Appendix A)
0 < Gr < 2000
All proprieties based upon average of surface temperatures.
H = ⎛ ----⎞
k
⎝ D⎠
Q = H * A s * (T w – T f )
Correlation 39
Inclined Spaces Between Flat Plates, Natural Convection, Hot Plate on Top and Cold Plate on
Bottom, (Ref. 6 in Appendix A)
0.0 < φ < 90.0
1.0E+03 < Ra < 1.0E+06
2.0E+04 < Gr < 2.0E+05
φ = angle inclined from the horizontal.
Ra number based on D.
Gr number based on D.
D = distance between plates.
L = length of plates.
All properties based upon average of plate temperatures.
T1 – T2
Definition: ----- = Ke * ⎛ ------------------⎞
Q
As ⎝ D ⎠
0.25 D 1 ⁄ 9
Ke = k * 1.0 + ⎛ 0.18 * Gr ⎛ ----⎞ – 1.0⎞ SIN ( ABS ( φ ) )
⎝ ⎝ L⎠ ⎠
Correlation 40
Inclined Spaces Between Flat Plates, Natural Convection Hot Plate on Top and Cold Plate on
Bottom, (Ref. 6 in Appendix A)
0.0 < Ra < 1.0E+06
2.0E+05 < Gr < 1.1E+07
φ = angle inclined from the horizontal.
Ra number based on D.
Gr number based on D.
D = distance between plates.
L = length of plates.
Main Index
Chapter 9: Convection Library 385
Convection Configurations
1⁄3 D 1⁄9
Ke = k * 1.0 + ⎛ 0.065 * Gr ⎛ ----⎞ – 1.0⎞ SIN ( ABS ( φ ) )
⎝ ⎝ L⎠ ⎠
Main Index
386 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 18
Annular Space Between Concentric Spheres, Natural Convection
Node Number 1 = outer sphere surface temperature, T 1 .
2 = inner sphere surface temperature, T 2 .
GP* 1 = surface area, of inner diameter of larger sphere, A s .
2 = radius at the location of the resistor surface area.
3 = gap (distance between spheres), D.
4 = radius of the inner sphere, R i .
5 =
gravitational constant, g .
Main Index
Chapter 9: Convection Library 387
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-18
Correlation 41
Annular Space Between Concentric Spheres, Natural Convection (Ref. 6 in Appendix A)
1.2E+02 < Ra < 1.1E+09
0.7 < Pr < 4148.0
D = distance between spheres (difference in radii)
Ro = outer radius = R i + D
Ri = inner radius
As = Surface Area
Main Index
388 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
4
g * β * D * ρ * ( T1 – T2 )
Ra = ------------------------------------------------------------------- * ⎛ -----⎞
D
μ α Ri ⎝ R i⎠
T1 – T2
Q = 4 * π * Ke * R i * R o * ------------------
Ro – Ri
0.226
Ke = k * 0.228 * Ra
Qs
H = -----------------------------------
-
As * ( T1 – T2 )
Q = H * A s * (T 1 – T 2 )
Main Index
Chapter 9: Convection Library 389
Convection Configurations
Configuration 19
Vertical or Inclined Surface, Uniform Heat Flux, Natural Convection
Node Number 1 = plate surface temperature, T 1 .
2 = fluid free-stream temperature, T 2 .
GP* 1 = plate/element’s surface area, A s .
2 = shortest distance between plate/element’s surface area and the surface edge
whose boundary layer thickness is zero, x=L i
3 = longest distance between plate/element’s surface area and the surface edge
whose boundary layer thickness is zero, x=L f .
4 = plate inclination angle φ in degrees from the horizontal. The value of φ must
be such that 0 < φ < 90, inclusive.
5 =
gravitational constant, g .
6 = estimated applied heat flux. QTRAN will constantly update this value to
reflect the actual heat flux applied to the surface. QTRAN will use your input
value only as an initial guess at the heat flux. Zero is an allowed guess, q.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid coefficient of thermal expansion, β .
4 = fluid specific heat, c p .
5 = fluid thermal conductivity, k.
Main Index
390 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-19
Correlation 42
Uniform Heat Flux, Vertical and Inclined Surface, Natural Convection
(Ref. 6 in Appendix A)
1.0E+05 < Ra < 1.0E+11
Ra number based on L.
L = plate length, in boundary layer flow direction.
φ = plate angle from the horizontal.
4
g * β * ρ * L * Q-
Ra = ----------------------------------------------
k * μ * α * As
Q = H * A s * (T w – T f )
Correlation 43
Uniform Heat Flux, Vertical and Inclined Surface, Natural Convection
(Ref. 6 in Appendix A)
2.0E+13 < Ra < 1.0E+16
Main Index
Chapter 9: Convection Library 391
Convection Configurations
Ra number based on L.
L = plate length, in boundary layer flow direction.
φ = plate angle from the horizontal.
4
Ra = g * β * ρ * L * Q-
----------------------------------------------
k * μ * α * As
Q = H * A s * (T w – T f )
Main Index
392 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 20
Vertical Enclosed Space, Uniform Heat Flux, Natural Convection
Node Number 1 = plate 1’s surface temperature (arbitrary), T 1 .
2 = plate 2’s surface temperature (arbitrary), T 2 .
GP* 1 = plate/element’s surface area that is exposed to the enclosed space, A s .
2 =
gravitational constant, g .
Main Index
Chapter 9: Convection Library 393
Convection Configurations
Figure 9-20
Correlation 44
Uniform Heat Flux, Vertical Enclosed Space, Natural Convection (Ref. 6 in Appendix A)
1.0E+04 < Ra < 3.0E+06
1.0 < Pr < 2.0E+04
Lc = space height.
D 0.30
* ⎛ -----⎞
0.25 0.012
Ke = k * 0.42 * Ra * Pr
⎝ L c⎠
Main Index
394 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 45
Uniform Heat Flux, Vertical Enclosed Space, Natural Convection (Ref. 6 in Appendix A)
1.0E+06 < Ra < 1.0E+09
1.0 < Pr < 20.0
Lc = space height.
1§3
Ke = k * 0.046 * Ra
Main Index
Chapter 9: Convection Library 395
Convection Configurations
Configuration 21
Combined Natural and Forced Convection in Horizontal Tubes
Node Number 1 = tube/element inside wall temperature, T 1 .
2 = fluid entrance temperature, T 2 .
3 = fluid exit temperature, T 3 .
GP* 1 = tube/element’s surface area on inside of tube, A s .
2 = shortest distance between element’s fluid exit area and the tube inlet, x=L i .
3 = longest distance between element’s fluid exit area and the tube inlet, x=L f .
4 =
gravitational constant, g .
5 =
average fluid velocity, v.
6 = tube inside diameter, D.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid coefficient of thermal expansion, β .
4 = fluid specific heat, c p .
Main Index
396 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-21
Correlation 46
Combined Natural and Forced Convection In Horizontal Tubes, Laminar Flow
(Ref. 6 in Appendix A)
Gr
--------- >> 1.0
2
Re
Gr number based on D.
D = tube diameter.
D
Gz = Graetz number = Re * Pr * -----
Lc
Q = H * A s * LMTD
Main Index
Chapter 9: Convection Library 397
Convection Configurations
Correlation 47
Combined Natural and Forced Convection In Horizontal Tubes, Turbulent Flow
(Ref. 6 in Appendix A)
Gr
--------- ( << 1.0 )
2
Re
Gr number based on D.
D = tube diameter.
Lc = tube length.
0.07 D 0.36
H = ⎛ ----⎞ *4.69 * Re * Gr ⎛ -----⎞
k 0.27 0.21
* Pr
⎝ D⎠ ⎝ L c⎠
Q = H * A s * LMTD
Main Index
398 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 22
Filmwise Condensation on a Vertical Surface
Node Number 1 = plate/element surface temperature, T 1 .
2 = vapor temperature, T 2 .
GP* 1 = plate/element’s surface area, A s .
2 = shortest distance between plate/element’s surface area and the top edge of
the vertical surface, x=L i .
3 = longest distance between plate/element’s surface area and the top edge of the
vertical surface, x=L f .
4 = wetted perimeter of plate/element surface, p.
5 = mass flow rate of condensate, M DOT .
6 =
gravitational constant, g .
Main Index
Chapter 9: Convection Library 399
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-22
Correlation 48
Filmwise Condensation on Vertical Surface, Horizontal Tubes, Turbulent Flow
(Ref. 6 in Appendix A)
Re < 1800
M DOT
= ρ * U * --- = 4 * ⎛ ---------------⎞
L
Re
μ ⎝ P * μ⎠
Main Index
400 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
ρ Liquid density.
l
U Average film velocity.
L cross-sectional area
4 * -----------------------------------------------
wetted perimeter
μ Liquid viscosity.
l
L Surface height.
ρV Vapor density.
T sat Saturation temperature.
Tw Wall temperature.
4 3 ρ * ( ρ – ρ v ) * g * h fg 0.25
H = --- * k * ---------------------------------------------------------------
3 4.0 * μ * ( T sat – T w ) * L
Q = H * A s * (T 1 – T 2 )
Correlation 49
Filmwise Condensation on Vertical Surface, Turbulent Flow (Ref. 6 in Appendix A )
(1800. < Re)
M DOT
Re = ρ * U * --- = 4 * ⎛ ---------------⎞
L
μ ⎝ P * μ⎠
ρ Liquid density.
l
U Average film velocity.
L cross-sectional area
4 * -----------------------------------------------
wetted perimeter
μ Liquid viscosity.
l
Main Index
Chapter 9: Convection Library 401
Convection Configurations
P Wetted perimeter.
k Liquid conductivity.
l
L Surface height.
ρV Vapor density.
T sat Saturation temperature.
Tw Wall temperature.
3 1⁄3
0.4 k * ρ * ( ρ – ρv ) * g
H = 0.0077 * Re * ---------------------------------------------------
2
-
μ
Q = H * A s * (T 1 – T 2 )
Main Index
402 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 23
Filmwise Condensation on a Horizontal Tube
Node Number 1 = tube/element outside wall temperature, T 1 .
2 = vapor temperature, T 2 .
GP* 1 = tube/elements outside surface area A s .
2 =
gravitational constant, g .
Figure 9-23
Main Index
Chapter 9: Convection Library 403
Convection Configurations
Correlation 50
Filmwise Condensation on Horizontal Tube (Ref. 6 in Appendix A)
Main Index
404 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
k Liquid conductivity.
l
ρ Liquid density.
l
ρV Vapor density.
g Gravitational constant.
h fg Enthalpy of phase change.
μ Liquid viscosity.
l
Tw Wall temperature.
Do Tube diameter.
H k l *ρ * ( ρ – ρ v ) * g * h fg 0.25
0.73 * ------------------------------------------------------------------
μ * ( T sat – T w ) * Do
Q H * A s * (T 1 – T 2 )
Main Index
Chapter 9: Convection Library 405
Convection Configurations
Configuration 24
Pool Boiling
Node Number 1 = inside wall temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = liquid contact surface area, A s .
2 = CSF (experimental constant).
Pool Boiling Liquid/Surface Combination Factor
Correlation 51
Main Index
406 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Tw Wall temperature.
Q H * A* (T w – T sat )
⎛ C pl * DIFF ⎞ 3 μ l * h fg
H = ⎜ --------------------------------------
-⎟ * ------------------------------------------------
σ -
⎝ h fg * Pr * CSF⎠ s
l
DIFF * --------------------------
( ρl – ρv )
Q = H * A s * B(T 1 – T 2 )
Figure 9-24
Main Index
Chapter 9: Convection Library 407
Convection Configurations
Configuration 25
Forced Convection Through Packed Beds
Node Number 1 = bed temperature, T 1 .
2 = fluid entrance temperature, T 2 .
3 = fluid exit temperature, T 3 .
GP* 1 = bed surface area, A s .
2 = ratio of bed surface area to bed volume, A.
3 = mass flux (mass flow/unit cross-sectional area of bed), G o .
4 = particle shape factor, ψ .
MPID 1 = fluid absolute viscosity, μ .
2 = fluid specific heat, C p .
3 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-25
Correlation 52
Forced Convection Through a Packed Bed (Ref. 8 in Appendix A)
(Re < 50)
Main Index
408 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
1.00 (spheres)
0.91 (cylinders)
0.86 (flakes)
0.79 (raschig rings)
0.67 (partition rings)
0.80 (berl saddles)
μ FILM Absolute viscosity at film temperature.
Pr Prandtl number at film temperature.
Re
Go
Reynolds number = -----------------------------------------
-
( A * μ FILM * ψ )
H 0.91 * ψ * C p G o
---------------------------------------------
0.51 2⁄3
Re * Pr
Q = H * A s * LMTD
Correlation 53
Forced Convection Through a Packed Bed (Ref. 8 in Appendix A)
(Re > 50)
Main Index
Chapter 9: Convection Library 409
Convection Configurations
1.00 (spheres)
0.91 (cylinders)
0.86 (flakes)
0.79 (raschig rings)
0.67 (partition rings)
0.80 (berl saddles)
μ FILM Absolute viscosity at film temperature.
Pr Prandtl number at film temperature.
Re Go
Reynolds number = --------------------------------------------
-
( A * μ FILM * ψ )
H 0.61 * ψ * C p G o
---------------------------------------------
0.41 2⁄3
Re * Pr
Q H * A s * LMTD
Configuration 26
Generic Natural Convection, H=H(TDIFF)
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = generic convection correlation coefficient, GP (2).
3 = generic convection correlation exponent, GP (3).
MPID (Not used)
Main Index
410 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Figure 9-26
Correlation 54
Generic Natural Convection
H=GP(2) * ABS(T 1 – T2)GP 3
Q = H * As* (T1 – T2 )
Main Index
Chapter 9: Convection Library 411
Convection Configurations
Configuration 27
Generic Natural Convection, H=H(Gr, Pr)
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 =
gravitational constant, g .
3 = characteristic length, L c .
4 = coefficient for convective equation, GP (4).
5 = Grashoff number exponent, GP (5).
6 = Prandtl number exponent, GP (6).
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid coefficient of expansion, β .
4 = fluid specific heat, C p .
5 = fluid thermal conductivity, k.
Figure 9-27
Main Index
412 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 55
Generic Natural Convection
GP(5) GP(6)
H = GP(4) * Gr *Pr
Q = H * A s * (T 1 – T 2 )
Main Index
Chapter 9: Convection Library 413
Convection Configurations
Configuration 28
Generic Forced Convection
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = characteristic length used for Reynolds number, L c .
3 =
fluid free stream velocity, v.
4 = coefficient for correlation, GP (4).
5 = Prandtl number exponent, GP (5).
6 = Reynolds number exponent, GP (6).
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, C p .
4 = fluid thermal conductivity, k.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-28
Main Index
414 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 56
Generic Forced Convection
GP(5) GP(6)
H = GP(4) * Pr *Re
Q = H * A s * (T 1 – T 2 )
Configuration 29
Generic H Value, H = H(TBAR) or H(time)
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
MPID 1 = H value (entered as a material property). This value is evaluated as a function
of the average of the two nodes' temperatures. If the MPID is flagged with
time as the independent variable, it will be used instead of the average
temperature.
Figure 9-29
Main Index
Chapter 9: Convection Library 415
Convection Configurations
Correlation 57
Generic H Value, H = H(tbar)
( T1 + T2 )
H = H ( T BAR ) , T BAR = ----------------------
-
2
Q = H * A s * (T 1 – T 2 )
Configuration 30
Generic H Value, H = H(TDIFF)
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
MPID 1 = H value (entered as a material property). This value is evaluated as a function
of the absolute value of the temperature difference of the two nodal
temperatures.
Figure 9-30
Correlation 58
Generic H Value, H = H(TDIFF)
H = H ( T DIFF ) , T DIFF = ABS ( T 2 – T 1 )
Main Index
416 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Q = H * A s * (T 1 – T 2 )
Configuration 31
Constant H Value
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = constant H value.
MPID (Not used)
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-31
Correlation 59
Generic Constant H Value
H = GP(2)
Q = H * A s * (T 1 – T 2 )
Configuration 32
Rotating Disk
Main Index
Chapter 9: Convection Library 417
Convection Configurations
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-32
Correlation 60
Rotating Disk
r = ( ri + ro ) ⁄ 2
V= ω*r
Main Index
418 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Re = ρ * V * r ⁄ μ (Reynolds Number)
/
Pr = Cp * μ k (Prandtl Number)
H = 0.0267 * ⎛ --⎞ * Pr * Re
k 0.6 0.8
⎝ r⎠
Q 2 → 1 = H*A s * ( T 2 – T 1 )
Main Index
Chapter 9: Convection Library 419
Convection Configurations
Configuration 33
Forced Convection, Smooth Isothermal Tubes
Node Number 1 = tube/element inside wall temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = tube/element’s inside surface area.
2 = distance from upstream tube section to the tube inlet, x = L i .
3 = distance from downstream tube section to the tube inlet, x = L f .
4 = tube inner diameter, D i .
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, C p .
4 = fluid thermal conductivity, k.
5 =
average fluid velocity, v.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-33
Note: This configuration is identical to Configuration 1, 347 and its accompanying correlations,
except that it requires only 2-noded resistors and uses DT instead of an LMTD.
Main Index
420 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Configuration 34
Smooth Tubes, Constant Heat Flux, Turbulent Flow, Forced Convection
Node Number 1 = tube/element inside wall temperature, T1 1 .
2 = fluid temperature, T 2 .
GP* 1 = tube/element’s inside surface area, A s .
2 = distance from upstream tube section to the tube inlet, x = L i .
3 = distance from downstream tube section to the tube inlet, x = L f .
4 = tube inside diameter, D i .
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, C p .
4 = fluid thermal conductivity, k.
5 =
average fluid velocity, v.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-34
Note: This configuration is identical to Configuration 2, 350 and its accompanying correlations,
except that it requires only 2-noded resistors and uses DT instead of an LMTD.
Main Index
Chapter 9: Convection Library 421
Convection Configurations
Configuration 35
Combined Natural and Forced Convection in Horizontal Tubes
Node Number 1 = tube inside wall temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = tube/element’s inside surface area, A s .
2 = distance from upstream tube section to the tube inlet, x = L i .
3 = distance from downstream tube section to the tube inlet, x = L f .
4 =
gravitational constant, g.
5 = tube inside diameter, D.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid coefficient of thermal expansion, β .
4 = fluid specific heat, C p .
5 = fluid thermal conductivity, k.
6 =
average fluid velocity, v.
*GP1 is provided by Patran; GP2 and GP3 can be optionally provided in the Convection Loads/BC
Convection Coefficient input databox.
Figure 9-35
Main Index
422 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Note: This configuration is identical to Configuration 21, 395 and its accompanying correlations,
except that it requires only 2-noded resistors and uses DT instead of an LMTD.
Configuration 36
Forced Convection Through Packed Beds
Node Number 1 = bed temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = bed surface area, A s .
2 = ratio of bed surface area to bed volume, A.
3 = particle shape factor, ψ .
MPID 1 = fluid absolute viscosity, μ .
2 = fluid specific heat, C p .
3 = fluid thermal conductivity, k.
4 = mass flux (mass flow/unit cross-sectional area of bed), G o .
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-36
Note: This configuration is identical to Configuration 25, 407 and its accompanying correlations,
except that it requires only 2-noded resistors and uses DT instead of an LMTD. In addition,
this configuration allows the mass flux to be a variable rather than a constant as is the case
with Configuration 25, 407.
Main Index
Chapter 9: Convection Library 423
Convection Configurations
Configuration 37
Contact Resistance with an Interstitial Fluid
Node Number 1 = surface temperature of surface 1, T 1 .
2 = surface temperature of surface 2, T 2 .
GP* 1 = element’s surface area, A.
2 = rms roughness (meters) of surface T 1 , σ 1
3 = rms roughness (meters) of surface T 2 , σ 2
4 = mean free path at 15 °C and 1 atm, Λ 0 .
5 = 2l
temperature jump ratio -----
-
Λ0
Correlation 61
Contact Resistance
Configuration 37 originally was based on Ref. 12 in Appendix A. With Version 8, the correlation has
been redone based on the original work defined in Ref. 13 in Appendix A. The ability to input fluid
pressure was added to the correlation.
This correlation which defined the total conductance between two surfaces is assumed to be the sum of
two mutually independent conductances-the component through the interstitial fluid and that through the
contacting area.
hc = hf + hm
These are dependent on the contact area and equivalent fluid thicknesses which in correlation are
correlated to fluid characteristics and material properties.
Main Index
424 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
The fluid conductance is defined by its conductance and the fluid equivalent thickness.
k
h f = -----f
δe
where:
Data has been correlated over a wide range by the following expression:
δ max
Y = ----------
δe
δ max
X = ----------
2l
where:
δ max the maximum distance between surfaces and as a first approximation can be taken as
twice the mean roughness of each surface.
δ max 2 ( σ1 + σ2 )
Cp ⁄ Cv
l = ⎛ ------------⎞ ⎛ -----⎞ ⎛ --------------------------------⎞ Λ
2–a 2
⎝ a ⎠ ⎝ P r⎠ ⎝ C p ⁄ ( C v + 1 )⎠
It is often difficult to pinpoint a value for the accommodation coefficient and this reference provides a
table for some gases. It should be noted that the mean free paths quoted in this reference are at best 50%
higher than many other references, but are provided to be consistent with the reference the correlation
was developed in.
Main Index
Chapter 9: Convection Library 425
Convection Configurations
The mean free path is directly proportional to absolute temperature and inversely proportional to
pressure. The corrections for actual conditions is adjusted with the following relation:
T Po
Λ = Λ o ⎛ ------⎞ ⎛ -----⎞
⎝ T o⎠ ⎝ P f ⎠
where all the reference values are related to 15 °C and 1 atmosphere. All fluid material properties are
evaluated at the average temperature of the surface nodes. Appropriate adjustment in the temperature
from the internal calculation units to units consistent with the correlation are done automatically;
however, all quantities must be in SI units
To = 288.15 K
Po = 101325 Pa
The second part of the conductance is that through the material which is in contact. This is dependent on
the contact pressure and material strength to define the effective area of conductance. The correlation for
this term is
C P c 0.86
h m = 8000k m ⎛ -----------⎞
⎝ 3 σ s⎠
km 2 * k1 * k2
---------------------------
-
k1 + k2
This equation is valid for relative contact pressure to strength ratios in the order of 0.025 and
temperatures below 0.3 of the fusion point. For higher or prolonged loads at elevated temperatures, creep
must be considered which increases the interface conductance.
The coefficient C is a function of the rms roughness of each surface.
Main Index
426 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
C = 1.0 if ( σ1 + σ2 ) > 30 × 10
–6
C = 14.42 × 10
–6 if ( σ1 + σ2 ) < 10 × 10
–6
Note: The 14.42 is an adjustment from what was defined in the reference in order to provide a
continuous function.
The final conductance involves a scale factor which can provide desired adjustments due to additional
knowledge about the surfaces or for units adjustment because some aspects of the correlation are
dependent on the SI unit’s system.
h = hc * F
where the area is equated based on the geometric node where the contact coupling is applied.
Main Index
Chapter 9: Convection Library 427
Convection Configurations
Configuration 38
Generic Forced Convection with Variable Velocity
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = characteristic length used for Reynolds number, L c .
3 =
fluid free stream velocity, v.
4 = coefficient for correlation, GP (4).
5 = Prandtl number exponent, GP (5).
6 = Reynolds number exponent, GP (6).
MPID 1 = fluid density, ρ .
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-37
Main Index
428 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 62
Generic Forced Convection with Variable Velocity
Fluid velocity is the product of GP(2) and MPID(5) evaluation. The independent variable for velocity
evaluation is either the bulk fluid temperature or time.
Q = H * As * ( T1 – T2 )
Configuration 39
Generic H Value, H = H(Tb) * GP
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = Heat Transfer Coefficient Scale factor.
MPID 1 = Heat Transfer Coefficient Variable Definition.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-38
Main Index
Chapter 9: Convection Library 429
Convection Configurations
Correlation 63
Generic H Value, H = H(Tb) * GP(2)
Heat transfer coefficient is the product of GP(2) and MPID(1) evaluation. The independent variable for
the variable evaluation is either the bulk fluid temperature or time.
H = H(Tb) * GP(2)
Q = H * As * ( T1 – T2 )
Configuration 40
Generic H Value, H = H(Tb) * GP - Ignore Area
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = Heat Transfer Coefficient Scale factor.
MPID 1 = Heat Transfer Coefficient Variable Definition.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-39
Main Index
430 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Correlation 63
Generic H Value, H = H(Tb) * GP(2)
Heat transfer coefficient is the product of GP(2) and MPID(1) evaluation. The independent variable for
the variable evaluation is either the bulk fluid temperature or time. Although the surface area is defined,
it is not used to determine the heat flux.
H = H(Tb) * GP(2)
Q = H * ( T1 – T2 )
Main Index
Chapter 9: Convection Library 431
Convection Configurations
Configuration 41
Generic Forced Convection with Viscosity Correction
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = characteristic length used for Reynolds number, L c .
3 =
fluid free stream velocity, v.
4 = coefficient for correlation, GP (4).
5 = Prandtl number exponent, GP (5).
6 = Reynolds number exponent, GP (6).
7 = Viscosity Exponent if heating fluid, GP(7).
8 = Viscosity Exponent if cooling fluid, GP(8).
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, C p .
4 = fluid thermal conductivity, k.
5 = fluid velocity, variable dependence
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Main Index
432 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Figure 9-40
Correlation 64
Generic Forced Convection with Viscosity Correction when Heating fluid.
Fluid velocity is the product of GP(2) and MPID(5) evaluation. The independent variable for velocity
evaluation is either the bulk fluid temperature or time.
GP(5) GP(6)
H = k/Lc * GP(4) * Pr * Re * ( μ B ⁄ μ w )GP(7)
Q = H * As * ( T1 – T2 )
Correlation 65
Generic Forced Convection with Viscosity Correction when Cooling fluid.
Fluid velocity is the product of GP(2) and MPID(5) evaluation. The independent variable for velocity
evaluation is either the bulk fluid temperature or time.
GP(5) GP(6)
H = k/Lc * GP(4) * Pr * Re * ( μ B ⁄ μ w )GP(8)
Q = H * As * ( T1 – T2 )
Main Index
Chapter 9: Convection Library 433
Convection Configurations
Configuration 42
Generic Forced Convection with Temperature Correction
Node Number 1 = element surface temperature, T 1 .
2 = fluid temperature, T 2 .
GP* 1 = element’s surface area, A s .
2 = characteristic length used for Reynolds number, L c .
3 =
fluid free stream velocity, v.
4 = coefficient for correlation, GP (4).
5 = Prandtl number exponent, GP (5).
6 = Reynolds number exponent, GP (6).
7 = Temperature Exponent if heating fluid, GP(7).
8 = Temperature Exponent if cooling fluid, GP(8).
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, C p .
4 = fluid thermal conductivity, k.
5 = fluid velocity, variable dependence.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Main Index
434 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Figure 9-41
Correlation 66
Generic Forced Convection with Temperature Correction when Heating fluid.
Fluid velocity is the product of GP(2) and MPID(5) evaluation. The independent variable for velocity
evaluation is either the bulk fluid temperature or time.
GP ( 7 )
* ⎛ --------⎞
GP ( 5 ) GP ( 6 ) Tw
H = k / Lc * GP ( 4 ) * Pr * Re
⎝ Tb ⎠
Q = H * As * ( T1 – T2 )
Correlation 67
Generic Forced Convection with Viscosity Correction when Cooling fluid.
Fluid velocity is the product of GP(2) and MPID(5) evaluation. The independent variable for velocity
evaluation is either the bulk fluid temperature or time.
GP ( 8 )
* ⎛ --------⎞
GP ( 5 ) GP ( 6 ) Tw
H = k / Lc * GP ( 4 ) * Pr * Re
⎝ Tb ⎠
Q = H * As * ( T1 – T2 )
Main Index
Chapter 9: Convection Library 435
Convection Configurations
Configuration 43
Local Flat Plates, Forced Convection
Node Number 1 = plate/element surface temperature, T 1 .
2 = free-stream fluid temperature, T 2 .
GP* 1 = plate/element surface area, A s /element.
2 = distance to the plate’s leading edge, x=L i .
3 = free-stream fluid velocity, x=L scale factor.
MPID 1 = fluid density, ρ .
2 = fluid absolute viscosity, μ .
3 = fluid specific heat, c p .
4 = fluid thermal conductivity, k.
5 = variable fluid velocity.
*GP1 is provided by Patran; GP2 can be optionally provided in the Convection Loads/BC Convection
Coefficient input databox.
Figure 9-42
Velocity is the product of velocity scale factor and the variable velocity material property. All
temperature dependent material properties are evaluated at the film temperature.
Main Index
436 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Re < 2.0 E + 5
H = ⎛ ---⎞ * 0.565 *
k
Re * Pr
⎝ L⎠
H = ⎛ ---⎞ * 0.332 *
k 1⁄3
Re * Pr
⎝ L⎠
⎧ 1⁄3
⎫
k ⎪ 0.338 * Re * Pr ⎪
H = ⎛ ---⎞ ⎨ -----------------------------------------------------
-⎬
⎝ L⎠ ⎛ ⎞
2⁄3 1⁄4
⎪ 1 + ----------------
0.0468 ⎪
⎩ ⎝ Pr ⎠ ⎭
–1 ⁄ 5
C f = 0.0592 Re
0.37
C f = -----------------------------------
2.584
( log 10 Re )
1
--- * C f * Re * Pr
H = ⎛ ---⎞ ⋅ ----------------------------------------------------------------------------------------------------------------------------------
k 2
⎝ L⎠
1 ⎧ 5 ⎫
1.0 + 5 --- * C f ⎨ ( Pr – 1.0 ) + 1n 1.0 + --- ( Pr – 1 ) ⎬
2 ⎩ 6 ⎭
If Reynolds number between laminar and turbulent limits, a linear interpolation between the laminar and
turbulent values is used.
Main Index
Chapter 9: Convection Library 437
Convection Configurations
Q = H * As * ( T1 – T2 )
Configurations 44-999
Reserved (not currently used)
These configuration numbers are reserved for future expansion of the QTRAN convection correlation
library.
Configurations 1000+
User Supplied
These configuration numbers are reserved for User-Coded convection configurations that may be
incorporated into subroutine UHVAL. The calling sequence for UHVAL is as follows:
SUBROUTINE UHVAL (ICFIG, IRESIS, COEFF, EXPO, MPID, GP,
T1, T2, GVALH, Q, LOGP, J1, J2, J3, J4, J6)
An example UHVAL subroutine is included in the QTRAN package with excellent internal
documentation. Refer to it before attempting to write your own.
The arguments for UHVAL are defined as follows:
Main Index
438 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Convection Configurations
Main Index
Chapter 10: Microfunction Library
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
10 Microfunction Library
Main Index
440 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Microfunction Library
The following is a catalogue of the microfunctions that are available in the QTRAN Microfunction
Library, as well as an explanation of the various input parameters which are required for each
microfunction. Briefly, the microfunctions which are available are:
1. Constant
2. Power Series
3. Sine Wave
4. Square Wave
5. Step
6. Ramp
7. Exponential
8. Linear Interpolation of a User-Input Data Table
9. Hermite Polynomial Interpolation of a User-Input Data Table, with Quadratic Interpolation
Etrapolation at the Data Table End-Points
10. Repeating Waveform: Linearly Interpolated Data Table
11. Repeating Waveform: Hermite Polynomial Interpolated Data Table
12. Natural Logarithm
13. Base 10 Logarithm
14. Blackbody Radiation (this function determines the fraction of blackbody radiant energy that lies
between two wavelengths)
15. Flip/Flop
16. Dead Band (this function allows for hysteresis effects)
17. Straight Line
18. Indexed Linear Interpolation of a User-Input Data Table
19. Indexed Hermite Polynomial Interpolation of a User-Input Data Table, with Quadratic
Interpolation/Extrapolation at the Data Table End-Points
20. Indexed Repeating Waveform: Linearly Interpolated Data Table
21. Indexed Repeating Waveform: Hermite Polynomial Interpolated Data Table
22.Repeating Flip/Flop
23-999 Reserved for Future Use (not currently implemented)
1000+ User-Coded (a function defined by a user-supplied subroutine UMICRO)
The variable X that is referred to in the following function explanations refers to the independent variable
that you specify. As described in Microfunction Data, 322, the independent variable may be either the
current time value, the temperature value of any node, the temperature difference between any two nodes,
a radiosity difference, or the average temperature of any two nodes.
Main Index
Chapter 10: Microfunction Library 441
Microfunction Library
Microfunction Format
MFID, Independent Variable, and Function Type
MICRO(keyword) MFID ARGUMENT OPTION
Example
MICRO2709
This begins a microfunction data packet for MFID 27, with 0 (time) as the independent argument, and
option 9 (Hermite table) as the function type.
Parameter Description
MFID The MicroFunction Identification number. Each microfunction must be assigned
a unique MFID number greater than zero. This MFID number will be referenced
by the macrofunctions on (p. 325) through (p. 331) in the same manner as a
material property ID number (MPID) is referenced by resistors and capacitors.
This referencing scheme allows the same microfunction to be used in many
different macrofunctions.
ARGUMENT Identifies the microfunction independent variable as time, temperature (T), D T,
radiosity difference or an average temperature according to the following
argument code:
0--t(time)
1--T(temperature)
(T + T )
1 2 - (average temperature)
4-- Tbar = ------------------------------
2
OPTION Identifies the Function Library option that has been selected. For more
information, consult the Function Library in Microfunction Options, 442. If the
Function Library option number is entered as the negative of the option number
(e.g., specify option 2 as option -2), QTRAN will use the reciprocal of the
function. For example, SIN(X) would be evaluated as (1/SIN(X)).
Main Index
442 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Microfunction Options
Each microfunction option that is available is described below.
Option 1 - Constant
Option 1 is a constant of the following form:
F(X) = P1
where:
P1 is the first MICDAT value entered for the microfunction. See Microfunction Parameters or
Data Tables, 324.
Example
MICRO1101
MICDAT23.7
/
MICDAT(4)
MICDAT(3) * X +
... +
MICDAT(N)
MICDAT(N-1) * X
where:
Main Index
Chapter 10: Microfunction Library 443
Microfunction Library
The MICDAT(1...N) are tabular input data that is supplied for the microfunction as outlined in
Microfunction Parameters or Data Tables, 324.
For example, suppose microfunction number 12 is defined to be a temperature dependent power series
of the following form.
1.5 0.3 4.731
F(X) = 1.2 * X + 83.7* X + 0.1* X
Example
MICRO1212
MICDAT1.21.5
MICDAT83.70.3
MICDAT0.14.731
/
where:
P1, P2, P3, and P4 are the MICDAT(1) to MICDAT(4) parameters referred to in Microfunction
Parameters or Data Tables, 324. The arguments (P2 * X + P3) are in radians.
For example, suppose microfunction 11 is defined to be a time dependent sine wave of the following
form:
F(X)=23.7 * SIN(14.8E+03 * X - 18.7) +1.456E+03
Example
MICRO1103
MICDAT23.714.8E+03 -18.7 1.456E+03
/
Main Index
444 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
For example, suppose that you want to define microfunction 14 to be a time dependent square wave with
a frequency of 18.7, a phase angle of 44.7, a maximum value of 0.17 and a minimum value of 0.14.
Example
MICRO1404
MICDAT0.170.1418.744.7
/
Main Index
Chapter 10: Microfunction Library 445
Microfunction Library
For example, suppose microfunction 15 is defined to be a step function using temperature difference as
the argument (remember that the node temperatures are defined by the calling macrofunction) and that
the step function form is as follows:
IF (X < 11.78) THEN
F(X) = 84.89
ELSE
F(X) = -77.67
ENDIF
Example
MICRO1525
MICDAT11.7884.89-77.67
/
Main Index
446 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
For example, suppose microfunction 16 is defined to be a time-dependent ramp function of the following
form:
where:
Example
MICRO1606
MICDAT10.020.0100.0 200.0
/
Main Index
Chapter 10: Microfunction Library 447
Microfunction Library
where:
MICDAT(1...N) are the parameters referred to in Microfunction Parameters or Data Tables, 324.
For example, suppose microfunction 17 is to be defined to be an exponential function using the radiosity
potential difference between two nodes as the argument with the exponential function having the
following form:
-23.7
F(X) = 0.17 * e * (X+273.15)
Example
MICRO1737
MICDAT0.17-23.7-273.150.0
/
Main Index
448 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
100.0 17.3
200.0 84.9
1000.7 987.9
Example
MICRO1818
MICDAT0.00.0
MICDAT100.0 17.3
MICDAT200.084.9
MICDAT1000.7987.9
/
Main Index
Chapter 10: Microfunction Library 449
Microfunction Library
Example
MICRO1819
MICDAT0.00.0
MICDAT100.017.3
MICDAT200.084.9
MICDAT1000.7987.9
/
If Option 9 is used, at least three data pairs must be defined.
Main Index
450 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Example
MICRO20010
MICDAT0.00.0
MICDAT50.0100.0
MICDAT100.00.0
/
Main Index
Chapter 10: Microfunction Library 451
Microfunction Library
This particular wave begins at time = 0.0. To cause a phase shift, all you have to do is to change the time
values. The function as defined above will repeat the triangular heat pulse every 100.0 seconds.
If Option 10 is used, at least two data pairs must be entered.
50.0 20.0
75.0 0.0
100.7 -10.0
Example
MICRO21111
MICDAT10.010.0
MICDAT 50.020.0
MICDAT75.00.0
MICDAT100.0-10.0
/
If Option 11 is used, at least three data pairs must be entered.
Main Index
452 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
where:
MICDAT(1...4) are the parameters referred to in Microfunction Parameters or Data Tables, 324.
When using any log function, exercise care that the argument does not become negative because a log
function is undefined for negative arguments. If a log function argument does become negative, your
computer will probably detect an arithmetic floating point error and terminate. QTRAN does not check
for positive arguments.
For example, to define a time-dependent function of the following form.
F(X) = 17.7E-04 * Ln(17.7 * X + 123.4) + 1.0E-07
Example
MICRO22012
MICDAT17.7E-0417.7 123.41.0E-07
/
Main Index
Chapter 10: Microfunction Library 453
Microfunction Library
where:
MICDAT(1...N) are the parameters referred to in Microfunction Parameters or Data Tables, 324.
When using any log function, exercise care that the argument does not become negative, because a log
function is undefined for negative arguments. If a log function argument does become negative, the
computer will probably detect an arithmetic floating point error and terminate. QTRAN does not check
for positive arguments.
For example, to define a time-dependent function of the following form.
F(X) = 17.7E-04 * Log [10] ( 17.7 * X+123.4 ) + 1.0E-07
Example
MICRO23013
MICDAT17.7E-0417.7123.41.0E-07
/
Main Index
454 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Important:The values of MICDAT(1) and MICDAT(2) must be such that MICDAT(1) <
MICDAT(2).
Values for F(X,MICDAT(1),MICDAT(2)) will always be between the values of 0 and 1, inclusive.
The primary use of this microfunction option is to emulate QTRAN’s wavelength-dependent thermal
radiation algorithm using a heat source.
Example
MICRO101114
MICDAT0.20.6
/
Main Index
Chapter 10: Microfunction Library 455
Microfunction Library
The MICDAT(1...4) are the parameters referred to in Microfunction Parameters or Data Tables, 324. This
function is typically used for time-dependent heat sources that may be turned on for only a definite period
of time. As can be seen, a flip/flop function is really a kind of double step function that is fairly commonly
encountered.
For example, to build a model where a heat source of 1000.0 units is turned on at time = 17.8 and turned
off again at time = 19.2.
Example
MICRO25015
MICDAT17.819.21000.0 0.0
/
Main Index
456 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
A common use of this function is a hysteresis switch for thermostats, where the position of the switch
(on/off) is dependent not only upon the temperature of a node but also upon the node’s history. For
example, consider the following thermostatically controlled heater at node 1.
where:
To build a thermostat, introduce another temperature node T2. T2 will not be a “real” temperature node
but will instead be your hysteresis flag. T2’s temperature can be controlled with an Option 16
microfunction, letting the X of this microfunction be T1 and letting the MICDAT(1...4) values be 1.0,
60.0, 0.0, 80.0. Specifically we then have:
1. T2 = 1.0 if T1 < 60.0
2. T2 = 0.0 if T1 > 80.0
Main Index
Chapter 10: Microfunction Library 457
Microfunction Library
The thermostat control has been built, next build the heater. This can be done by using microfunction
option 17 (straight line) with the independent variable X of this microfunction being T2. For example, to
build a 1000-watt heater for node T1, use Option 17 with MICDAT(1) and MICDAT(2) values of 1000.0
and 0.0, respectively, where Option 17 is of the form:
F(X) = MICDAT(1) * X + MICDAT(2)
Since T2 is used for X in the Option 17 microfunction and T2 can only be 1.0 or 0.0 (according the
microfunction that controls T2), a complete (though simple) thermostatically controlled heater has been
built for node T1.
Example
MICRO26116
MICDAT1.060.00.080.0
/
See Option 17 for an example of a straight line microfunction.
where:
MICDAT(1) and MICDAT(2) are the parameters referred to in Microfunction Parameters or Data
Tables, 324.
Main Index
458 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
To build a straight line heat source such as the one described for the thermostatically controlled heater in
the Option 16 example. This straight line heater has the form:
F(X) = 1000.0 * X + 0.0
Example
MICRO27117
MICDAT1000.00.0
/
Main Index
Chapter 10: Microfunction Library 459
Microfunction Library
100.0 17.3
200.0 84.9
1000.7 987.9
Example
MICRO28118
MICDAT0.00.0
MICDAT100.017.3
MICDAT200.084.9
MICDAT1000.7987.9
/
Main Index
460 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Example
MICRO18 119
MICDAT0.00.0
MICDAT100.017.3
MICDAT200.084.9
MICDAT1000.7987.9
/
If Option 19 is used, at least three data pairs must be entered.
Example
MICRO 201020
MICDAT0.00.0
MICDAT50.0100.0
Main Index
Chapter 10: Microfunction Library 461
Microfunction Library
MICDAT100.00.0
/
This particular wave begins at time = 0.0. To cause a phase shift, change the time values. The function
as defined above will repeat the triangular heat pulse every 100.0 seconds.
If Option 20 is used, at least two data pairs must be entered.
50.0 20.0
75.0 0.0
100.0 -10.0
Example
MICRO123121
MICDAT10.010.0
MICDAT50.020.0
Main Index
462 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
MICDAT75.00.0
MICDAT100.0-10.0
/
If Option 21 is used, at least three data pairs must be entered.
The MICDAT(1...5) are the parameters referred to in Microfunction Parameters or Data Tables, 324. This
function is typically used for time-dependent heat sources that may be turned on and off for only a
definite periods of time. As can be seen, a repeating flip/flop function is really a kind of double step
function that can be turned on and off at repeatedly but can have different on and off time periods. The
period is P4 - P1.
For example, to build a model where a heat source of 1000.0 units is turned on between 19.2 and 26.4
second and repeated every 22.2 where the cycle begins at 17.8 seconds, the inputs would be as define
below.
Example
MICRO25015
Main Index
Chapter 10: Microfunction Library 463
Microfunction Library
MICDAT17.819.226.440.01000.0 0.0
/
Example
MICRO19901000
MICDAT0.0273.0
1.0375.0
2.0 376.0
100.0 390.0
101.0-37.36
115.027.0
Any macrofunction in the model that references MFID 199 will now return a value from the user-
supplied subroutine UMICRO.
Main Index
464 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Microfunction Library
Main Index
Chapter 11: User-Supplied Routines
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
11 User-Supplied Routines
Main Index
466 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
User-Supplied Subroutines
User-Supplied Subroutines
This chapter contains subroutines from the ULIBFOR file provided with P/THERMAL. These
subroutines are called at various key points in QTRAN’s calculation loop. See Figure 11-1. Any of these
routines may be modified and necessary for the analyses. Then compile and link them with QTRAN
using the ULIB command provided with P/THERMAL.
Many of these routines refer to a $INSERT file (a file included at compile time) named COMMONBLK.
COMMONBLK is a common block file of parameters used by QTRAN. This file is provided with
P/THERMAL, and the file has extensive comments describing the various common block parameters.
The user should only use the common blocks required for the individual subroutines being written. Each
type of variable is defined in separate include files but all are located through the COMMONBLK file.
The COMMONBLK_ALL includes individual files. COMMONBLK does NOT include arrays that are
in common. Common arrays may be found in the QTRANFOR file. The QTRAN arrays are defined in
section 11.5.
The user should check the COMMONBLK, COMMON****,ULIBFOR and sample QTRANFOR files
provided in the P3_HOME/p3thermal_files/lib directory to be sure you have the latest versions.
Main Index
Chapter 11: User-Supplied Routines 467
User-Supplied Subroutines
Main Index
468 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
COMMONBLK Definitions
It is best to only include the variables one needs in a given subroutine. Thus a group
of common blocks is supplied. The array common blocks are defined in section 11.5 plus
are in your qtran.f file. The various common blocks are shown below and can be found in
the P3_HOME/p3thermal_files/examples/qtran/utilities directory. Some common blocks are
include statements for other common blocks. All are listed below.
common.basc
common.blk
C The following is a list of the QTRAN common block variables.
C
C############################################################################
C
C Value of common block counters
C
C CB - 6 Character variables
C IA - 92 Integer arrays
C IB -117 Integer variables
C LA - 1 Logical arrays
C LB - 17 Logical variable
C RA - 77 Real (double precision) arrays
C RB -128 Real (double precision) variables
C
C#############################################################################
C
C Include all the different common block types
C
#include "common.intr"
#include "common.char"
#include "common.logc"
#include "common.real"
#include "common.dims"
C
C############################################################################
Main Index
Chapter 11: User-Supplied Routines 469
COMMONBLK Definitions
common.char
C The following is a list of the QTRAN character common block variables.
C
C############################################################################
C
C Value of common block counters
C
C CB - 6 Character variables
C
C#############################################################################
C
C
CHARACTER*1 ISCALE, ICCALC
CHARACTER*10 TLABEL
CHARACTER*256 RSTFNM, INPFIL(MAXFIL)
CHARACTER*80 TITLE(3)
C
C############################################################################
C
C This section is reserved for character variables. The convention is
C that all character common blocks will begin with the letters
C "CB".
C
COMMON / CB1 / ISCALE
COMMON / CB2 / ICCALC
COMMON / CB3 / TLABEL
COMMON / CB4 / RSTFNM
COMMON / CB5 / INPFIL
COMMON / CB6 / TITLE
C
C Usage:
C ISCALE --> temperature scale code for data output.
C ICCALC --> temperature scale code for calculations.
C TLABEL --> time units label.
C RSTFNM --> restart file name (if any).
C INPFIL --> input file names.
C TITLE --> First 3 lines of title data (if any) from the
C QIN.DAT file. This is saved for generating Nodal
C results files.
C
C############################################################################
common.dims
C The following are the array dimension control variables.
C
C############################################################################
C dims is the dimensions common block.
C
C j1 is the maximum number of convective resistors.
C j2 is the maximum number of material properties allowed for
C each convective resistor, and should be equal to 7.
C j3 is the maximum number of material properties allowed for the
C thermal system.
C ( j4 - 1 ) is the maximum number of material property data pairs
C allowed to describe a material property.
C j5 is the maximum number of conductive resistors.
C j6 is the maximum number of geometric properties allowed to describe
C a given convective resistor.
C j7 is the maximum number of non-tabular, non-power series
Main Index
470 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
Main Index
Chapter 11: User-Supplied Routines 471
COMMONBLK Definitions
common.int
C The following is a list of the QTRAN INTEGER common block variables.
C
C############################################################################
C
C Value of common block counters
C
C IA - 92 Integer arrays
C IB -117 Integer variables
C
C#############################################################################
C
C Declare the types of the common block variables.
C
C
C (MAXFIL - 1) is the maximum number of nested $INSERT files.
Main Index
472 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
C
INTEGER MAXFIL
INTEGER MAXFCH
C
PARAMETER ( MAXFIL = 10 )
PARAMETER ( MAXFCH = 256 )
C
INTEGER IOPT, IMAX, IMIN, IMAXSS, NC, NH, NR, NS, NX, IFI, ITI
INTEGER IFIXI, JTP, NF, NW, NCAPS, IST, NTEMPS, IPS, IPT, IS
INTEGER NODE, ICPNTR, IHPNTR, IRPNTR, IWPNTR, IQPNTR, IFPNTR
INTEGER ICAPPT, DCMF, IENODE, ITER, IIN, IO, STATUS, J, JI, IOPTR
INTEGER IRETN, NRF, NWRAD, IFAIL, NRAD, NMID, NPID, NMFID, CPUSEC
INTEGER CPUSAV, IBT, IBS, ISSDMP, IGSURF, IGPNTR, IXPNTR, IWSURF
INTEGER IPERTR, SOL, NITBUP, NRDUMP, LUDUMP, OWIDTH
INTEGER LINNUM(MAXFIL), FILPNT, IRESIS, INNERI, NPLTMP, LUPLOT
INTEGER IEMAXE, IFSRLX, IFTRLX, KQMAC, KTMAC, NMAXWD, RRRCNT
INTEGER KMMAC, KPMAC
INTEGER NRFORM, NRFWID
INTEGER NP, NUPNOD, IMMI, IPI, MPIDGH, MPIDGX, MPIDGY, MPIDGZ
INTEGER JH, JHI, IMPNTR, IMAXPR, IMAXHE, IMAXME, HIOPT, HSOL
INTEGER NTBHUP, HITER, HPITER, NHYCNT, NODEHY, IPPNTR, NPDUMP
INTEGER NPFWID, NFFWID
INTEGER NTCPL
INTEGER FPRTFL, JPRTFL
INTEGER IFLIPF, JFLIPF, MFLIPF
INTEGER OVRWFL
INTEGER MXHPIT
!!! INTEGER ICPNT
INTEGER HLFDTF
INTEGER TOTITR
INTEGER INDTPA
C
INTEGER IRQFLO(9)
INTEGER IDMNRF(20)
C
COMMON / IA73 / IDMNRF
C
C NOTE: Usage
C
C IDMNRF -> Flag to indicate what results quantities are to be put
C in the nodal results file.
C
C############################################################################
C
C This section contains the integer common blocks. The convention is
C that all integer common block names will begin with the
C letters "IB".
C
COMMON / IB1 / IOPT
COMMON / IB2 / IMAX
COMMON / IB3 / IMIN
COMMON / IB4 / IMAXSS
COMMON / IB5 / ISSDMP
COMMON / IB6 / NC
COMMON / IB7 / NH
COMMON / IB8 / NR
COMMON / IB9 / IFI
COMMON / IB10 / ITI
COMMON / IB11 / IFIXI
COMMON / IB12 / JTP
COMMON / IB13 / NF
COMMON / IB14 / NW
COMMON / IB15 / NCAPS
COMMON / IB16 / IST
COMMON / IB17 / NTEMPS
COMMON / IB18 / IBS
COMMON / IB19 / IBT
COMMON / IB20 / IS
Main Index
Chapter 11: User-Supplied Routines 473
COMMONBLK Definitions
Main Index
474 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
Main Index
Chapter 11: User-Supplied Routines 475
COMMONBLK Definitions
Main Index
476 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
common.logc
C The following is a list of the QTRAN logical common block variables.
C
C############################################################################
Main Index
Chapter 11: User-Supplied Routines 477
COMMONBLK Definitions
C
C Value of common block counters
C
C LA - 1 Logical arrays
C LB - 17 Logical variable
C
C#############################################################################
C
C Declare the types of the common block variables.
C
LOGICAL STEADY, ALGBRA, LOGP, CVFLAG, DTFLAG, INNER, TRACE,
$ RSTART, LEXIT, IHCVFL, LABORT, LNGSTA, LPRTHY,
2 PNRFLG, PNPFLG, PNFFLG
C
C############################################################################
C
C This section is reserved for logical variables. The convention is
C that all logical variable common blocks will have common
C block names beginning with the letters "LB".
C
COMMON / LB1 / STEADY
COMMON / LB2 / ALGBRA
COMMON / LB3 / LOGP
COMMON / LB4 / CVFLAG
COMMON / LB5 / DTFLAG
COMMON / LB6 / INNER
COMMON / LB7 / TRACE
COMMON / LB8 / RSTART
COMMON / LB9 / LEXIT
C*C* COMMON / LB10 / WSTDYS
COMMON / LB11 / IHCVFL
COMMON / LB12 / LABORT
COMMON / LB13 / LNGSTA
COMMON / LB14 / LPRTHY
COMMON / LB15 / PNRFLG
COMMON / LB16 / PNPFLG
COMMON / LB17 / PNFFLG
C
C Usage:
C STEADY --> steady state run flag. If .true., a steady state
C run is in progress. If .false., a transient
C run is in progress.
C ALGBRA --> algebraic node iteration flag. If .true., the
C current iteration being performed will involve
C only those nodes without capacitors. If .false.,
C the iteration will involve all nodes.
C LOGP --> logical print/no-print flag used during data input
C and also during resistor heat flow data output
C after print dumps. If .false., no data printed.
C If .true., data is printed.
C CVFLAG --> convergence flag. If .true., the steady state or
C transient iterations have converged. If .false.,
C convergence is incomplete.
C DTFLAG --> time step change flag.
C
C INNER --> inner iteration loop flag. If .true., a phase
C change is occurring and the bisection algorithm
C is iterating on the node changing phase.
C TRACE --> status file trace flag. If .true., all input data
C file lines are printed to the status file.
C RSTART --> restart flag, = .false. = normal run from initial
C conditions (default), = .true. = read the qin.dat
C file, then read the RSTART.DMP file and restart
C from the conditions stored in RSTART.DMP.
C LEXIT --> Exit flag, when true it indicates that the
C transient solution has finished and there are no
C more analysis desired.
C WSTDYS --> Logical flag that indicates if the last calculation
Main Index
478 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
common.real
C The following is a list of the QTRAN real common block variables.
C
C############################################################################
C
C Value of common block counters
C
C RA - 77 Real (double precision) arrays
C RB -128 Real (double precision) variables
C
C#############################################################################
C
C Declare the types of the common block variables.
C
double_precision TIME, DT, TSTART, TSTOP, TPRINT, EPSISS, EPSIT,
$ PERTUR, PERTU2, PERTSQ, DTMAX, RELAX, RELAXS, RELAXT,
$ TSFMIN, TSFMAX, BETAEX, BETAIM, DTOLD, EFACT, QGLOBL,
$ SBC, SMALL, TINY, HUGE, QVECTP, QVECTM, GSUM, GVALC,
$ BETA, PCBAND, DELMAX, DTP, ERROR, Q, T1, T2, T3, GVALH,
$ CLOCK, EOLDST, ERROLD, DTPRED, CP, BALNCE, Q12, Q21, GVAL,
$ QWAVE, QGRAY, EMISS, TAU, QSURF, GVALS, QSURFT, GVALT,
$ TTMAC, FOLD, DELT, F11, F22, RMFLOW, EPSIT2, TSAVE, CPDELT,
$ QINPUT, DTMIN, H, MINTMP, MAXTMP, BETMIN, BETMAX
double_precision PINITL, MGLOBL, GH, GX, GY, GZ, HYBETA, HDIAM,
1 HCSAA, HDLEN, HDX, HDY, HDZ, HPRHO, HPRHOE, HMU, HNU, HCP,
2 HEPS, HLOSCF, HFF, HWDOT, HREYN, HQFLOW, HHX, HHY, HHZ,
3 HHXREF, HHYREF, HHZREF, HDPHED, HP1, HP2, HDTEMP, HPHEAD,
4 PI, GRAVTY, BTINY, HPERRM, HMERRM, HERRMX, HYEPIS, DTMAXH,
5 HYTIME, HYOTIM, HUNITS
double_precision RSTIME
double_precision HYHDEP, HYMDEP, HYPREP
!!! double_precision TNODE
double_precision SUMQ
double_precision SUMCNV
double_precision SUMRAD
double_precision CLKDTM
C
C############################################################################
Main Index
Chapter 11: User-Supplied Routines 479
COMMONBLK Definitions
C
C This section is reserved for all real common blocks. The convention
C is that all real common block names will begin with the
C letters "RB".
C
COMMON / RB1 / TIME
COMMON / RB2 / DT
COMMON / RB3 / TSTART
COMMON / RB4 / TSTOP
COMMON / RB5 / TPRINT
COMMON / RB6 / EPSISS
COMMON / RB7 / EPSIT
COMMON / RB8 / PERTUR
COMMON / RB9 / PERTU2
COMMON / RB10 / PERTSQ
COMMON / RB11 / DTMAX
COMMON / RB12 / RELAX
COMMON / RB13 / RELAXS
COMMON / RB14 / RELAXT
COMMON / RB15 / TSFMIN
COMMON / RB16 / TSFMAX
COMMON / RB17 / BETAEX
COMMON / RB18 / BETAIM
COMMON / RB19 / DTOLD
COMMON / RB20 / EFACT
COMMON / RB21 / QGLOBL
COMMON / RB22 / SBC
COMMON / RB23 / SMALL
COMMON / RB24 / TINY
COMMON / RB25 / HUGE
COMMON / RB26 / QVECTP
COMMON / RB27 / QVECTM
COMMON / RB28 / GSUM
COMMON / RB29 / GVALC
COMMON / RB30 / BETA
COMMON / RB31 / PCBAND
COMMON / RB32 / DELMAX
COMMON / RB33 / ERROR
COMMON / RB34 / DTP
COMMON / RB35 / Q
COMMON / RB36 / T1
COMMON / RB37 / T2
COMMON / RB38 / T3
COMMON / RB39 / GVALH
COMMON / RB40 / CLOCK
COMMON / RB41 / EOLDST
COMMON / RB42 / ERROLD
COMMON / RB43 / DTPRED
COMMON / RB44 / CP
COMMON / RB45 / BALNCE
COMMON / RB46 / Q12
COMMON / RB47 / Q21
COMMON / RB48 / GVAL
COMMON / RB49 / QWAVE
COMMON / RB50 / QGRAY
COMMON / RB51 / EMISS
COMMON / RB52 / TAU
COMMON / RB53 / QSURF
COMMON / RB54 / GVALS
COMMON / RB55 / QSURFT
COMMON / RB56 / GVALT
COMMON / RB57 / TTMAC
COMMON / RB58 / DELT
COMMON / RB59 / FOLD
COMMON / RB60 / F11
COMMON / RB61 / F22
COMMON / RB62 / RMFLOW
COMMON / RB63 / EPSIT2
Main Index
480 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
Main Index
Chapter 11: User-Supplied Routines 481
COMMONBLK Definitions
Main Index
482 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
COMMONBLK Definitions
Main Index
Chapter 11: User-Supplied Routines 483
COMMONBLK Definitions
C############################################################################
Main Index
484 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 485
ULIBFOR Contents - Example User-Supplied Subroutines
C #
C ULOOP2 --> Called from QTRAN subroutine RESET2, this #
C subroutine may be used to perform any necessary #
C housekeeping or calculations prior to beginning #
C an iteration for either steady state or #
C transient runs. #
C #
C ULOOP3 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called at the beginning of #
C calculations for each node for each iteration. #
C Custom resistor types are one example of things #
C that might be appropriate for ULOOP3. #
C #
C ULOOP4 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called at the end of calculations #
C for each node for each iteration immediately #
C after the temperature for that node has been #
C updated. #
C #
C ULOOP5 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called at the end of each #
C steady state or transient iteration. This #
C routine can be used to perform auxiliary #
C calculations that must be performed in parallel #
C with the thermal calculations, e.g., fluid flow #
C calculations, mass transport calculations, or #
C anything else that is appropriate. #
C #
C ULOOP6 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called only after a steady state #
C calculation has converged. #
C #
C ULOOP7 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called after each transient time #
C step. #
C #
C UMCRPR --> Same as UMICRO call except the material property #
C parameters are passed as well. This enables the user #
C directly use material properties without having to #
C provide wrappers to properly define the dimensions #
C #
C UMICRO --> Called from QTRAN subroutine FLIB, this #
C subroutine is called whenever the user specifies #
C a microfunction option of 1000 or greater. This #
C allows the user to build and maintain custom #
C heat source or temperature boundary condition #
C functions that are too exotic to be covered by #
C any of the existing QTRAN microfunctions. #
C #
C UOUTPT --> Called from QTRAN subroutine QFLOW, this #
C subroutine may be used to print out customized #
C data immediately after the temperature data is #
C printed out for either transient or steady state #
C runs. UOUTPT data is printed out prior to the #
C resistor data. #
C #
C UPCPAC --> Called from CCAPAC when a user material property has #
C beeb defined for either the capacitor density or #
C specific heat. Even if the user properties are dummies #
C to flag a user defined capacitance determination, the #
C UPROP value must pass a value that will allow a #
C capacitor evaluation prior to the user defining it. #
C This routine is for users to be able to define and #
C control the phase change energy. #
C #
C UPLOT --> Called from CRUNCH after every converged #
C transient or steady state solution. #
C Specific plot information could be created and #
Main Index
486 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 487
ULIBFOR Contents - Example User-Supplied Subroutines
C rmdot is the vector that stores the mass flow rate data.
C icpflo is the vector that stores the specific heat material property
C i.d. number for the flow resistor.
C coeff and expo are the material property arrays for subroutine props.
C t1 is the temperature of node #1 of the flow resistor.
C t2 is the temperature of node #2 of the flow resistor.
C q12 is the heat flow from node #1 to node #2 of the resistor.
C q21 is the heat flow from node #2 to node #1 of the resistor.
C since "upwind" differencing is used, one of the two heat
C flows will always be zero (the upstream node will never
C have heat flowing to it from the downstream node.)
C rmflow is the computed mass flow rate.
C
C
C##############################################################################
C
C > > > > > MODIFICATION HISTORY < < < < <
C
C Modification: Calculate the energy transferred as the difference in
C the energy state at the two end points rather than the average
C movement between the two points.
C By: Haddock Date: 5 February 1991
C
C Modification: Energy state at the end points must be integrated
C from the base reference state. If we are only interested in
C energy movement, then we can integrate between the two points.
C By: Haddock Date: 13 February 1992
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
double_precision T1
double_precision T2
double_precision CP
double_precision Q12
double_precision Q21
double_precision GVAL
double_precision RMFLOW
C
INTEGER NRF
C
COMMON / IB39 / NRF
Main Index
488 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
COMMON / RB36 / T1
COMMON / RB37 / T2
COMMON / RB44 / CP
COMMON / RB46 / Q12
COMMON / RB47 / Q21
COMMON / RB48 / GVAL
COMMON / RB62 / RMFLOW
C
C############################################################################
C define call list variables
C
INTEGER ICPFLO( J30, 2 )
C
double_precision RMDOT(*), COEFF( J3, J4 ), EXPO( J3, J4 )
C
C############################################################################
C Declare the local variables.
C
double_precision RM1, RM2, DIFFT
double_precision CPEVAL
double_precision PROPS
C
C############################################################################
C Declare external functions
C
EXTERNAL CPEVAL
EXTERNAL PROPS
C
C############################################################################
C
C Check the flow direction, and then calculate the appropriate heat
C flow from the upstream node to the downstream node as
C follows:
C (1) compute the specific heat value CP
C (2) compute the conductance GVAL = mass flow rate * CP
C (3) compute the heat flow from the upstream node to the
C downstream node, and then set the heat flow from the
C downstream node to the upstream node to zero
C
C############################################################################
C
!C CP = CPEVAL( T1, T2, COEFF, EXPO, ICPFLO(NRF,1) )
C
!C RMFLOW = RMDOT(NRF)
C
!C IF(ICPFLO(NRF,2).NE.0) THEN
C
!C RM1 = RMFLOW * PROPS( COEFF, EXPO, T1, ICPFLO(NRF,2) )
!C RM2 = RMFLOW * PROPS( COEFF, EXPO, T2, ICPFLO(NRF,2) )
!C RMFLOW = ( RM1 + RM2 ) * 0.5D+00
!C ENDIF
C
!C GVAL = ABS( RMFLOW * CP )
C
!C DIFFT = ( T1 - T2 )
C
!C IF(RMFLOW.GE.0.D+00) THEN
!C Q12 = GVAL * DIFFT
!C Q21 = 0.0D+00
!C ELSE
!C Q21 = GVAL * (-DIFFT)
!C Q12 = 0.0D+00
!C ENDIF
C
C############################################################################
C
RETURN
Main Index
Chapter 11: User-Supplied Routines 489
ULIBFOR Contents - Example User-Supplied Subroutines
END
C
C############################################################################
C #
C S U B R O U T I N E U C C P A C #
C #
C############################################################################
C
SUBROUTINE UCCPAC( CT, CSUM, C, CP, CM,
1 ICPNT, CNPNT, CPROP, CRHO, CVOL,
2 ICP, IRHO, COEFF, EXPO, IPERTR,
3 OT, TNODE, TP, TM,
4 T, TPLUSP, TMNUSP,
5 TDIFF, TDIFFP, TDIFFM )
C
C############################################################################
C #
C This subroutine performs all capacitance when a user defined #
C property has be defined. #
C #
C############################################################################
C
C
C declare the subroutine arguments, where:
c ct --> thermal capacity of this capacitor.
c csum --> sum of all capacitances to this node.
c c --> capacitance energy at new temperature.
c cp --> capacitance energy at plus perturbed temperature.
c cm --> capacitance energy at minu sperturbed temperature.
c icpnt --> index to capacitor in cnpnt array.
c cnpnt --> array containing the capacitor i.d. numbers for each
c node. all zeros are packed out.
c cprop --> array of specific heat mid numbers for each capacitor.
c crho --> array of density mid numbers for each capacitor.
c cvol --> array containing capacitor volumes.
c icp --> specific heat material property type.
c irho --> density material property type.
c coeff --> material property data array.
c expo --> material property data array.
c ipertr --> perturbation flag.
c ot --> old temperature value.
c tnode --> weighted new temperature.
c tp --> weighted new temperature and plus perturbation.
c tm --> weighted new temperature and minus perturbation.
c t --> new temperature value.
c tplusp --> new temperature value plus perturb.
c tmnusp --> new temperature value minus perturb.
c tdiff --> temperature change.
c tdiffp --> temperature change plus perturb.
c tdiffm --> temperature change minus perturb.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
Main Index
490 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
C Declare the arrays.
C
DOUBLE PRECISION CP
DOUBLE PRECISION TNODE
DOUBLE PRECISION COEFF( J3, J4 ), EXPO( J3, J4 )
DOUBLE PRECISION CVOL(*)
C
INTEGER IPERTR
INTEGER ICPNT
INTEGER CNPNT(*), CPROP(*), CRHO(*)
C
C############################################################################
C
C Some common blocks
C
C*C*RLH INTEGER ICMPID
C*C*RLH INTEGER IRMPID
C*C*RLH INTEGER MPID
C*C*RLH INTEGER MID
C
C*C*RLH COMMON / IA45 / MID(1)
C
C
C############################################################################
C
C Declare the local variables.
C
DOUBLE PRECISION CSUM, C, TP, TM, TDIFF
DOUBLE PRECISION TDIFFP, TDIFFM, CT, OT, T
DOUBLE PRECISION CM
DOUBLE PRECISION TPLUSP, TMNUSP
DOUBLE PRECISION CPEVAL, PROPS
DOUBLE PRECISION LCP
DOUBLE PRECISION LRHO
C
INTEGER ICP, IRHO
C
C*C*RLH DOUBLE PRECISION LOCT
C
C############################################################################
C Declare external functions
C
C*C*RLH EXTERNAL CPEVAL, PROPS
C
C#######################################################################
C
C
C-----------------------------------------------------------------------
C
! Note: If a user defined heat capacity or density has been defined
! as a user defined material property, then the uprops routine has
! been called and the heat capacity was determined with the
! following procedure. If the uprop for the given uprop is a
! dummy only to flag a user defined heat capacity, then the user
! can recalculate the heat capacity or mark appropriate modifications.
C
Main Index
Chapter 11: User-Supplied Routines 491
ULIBFOR Contents - Example User-Supplied Subroutines
C#######################################################################
C
C this section is for non-phase change behavior. compute
C the nodal capacitance energy, where:
C c = cp * rho * vol * dT. then do the same thing
C for the perturbed temperature values. note that
C the C, CP, and CM variables will store the sum of
C all capacitance heat flows for the node. the
C variable csum will store the sum of all nodal
C capacitances, and will be used for computing
C explicit stable time steps.
C
C*C*RLH ICMPID = MID( ICP )
C*C*RLH IRMPID = MID( IRHO )
C
C*C*RLH IF( ICMPID .EQ. 303105 .OR. ICMPID .EQ. 370705 .OR.
C*C*RLH 1 IRMPID .EQ. 303104 .OR. IRMPID .EQ. 370704 ) THEN
C
C*C*RLH IF( IPERTR .EQ. 0 ) THEN
C
C............................................................................
! Evaluate at temperature T
!
C*C*RLH LOCT = T
C
C*C*RLH ELSE IF( IPERTR .EQ. 1 ) THEN
C
C............................................................................
! Evaluate at temperature plus perturbed temperature.
!
C*C*RLH LOCT = TPLUSP
C
C*C*RLH ELSE IF( IPERTR .LE. -1 ) THEN
C
C............................................................................
! Evaluate at temperature minus perturbed temperature.
C
C*C*RLH LOCT = TMNUSP
C
C*C*RLH END IF
C
C*C*RLH IF( ICMPID .EQ. 303105 .OR. ICMPID .EQ. 370705 ) THEN
C
C*C*RLH LCP = EXPO( ICP, 2 )
C
C*C*RLH ELSE
C
C*C*RLH LCP = CPEVAL( OT, LOCT, COEFF, EXPO, ICP )
C
C*C*RLH END IF
C
C*C*RLH IF( IRMPID .EQ. 303104 .OR. IRMPID .EQ. 370704 ) THEN
C
C*C*RLH LRHO = EXPO( IRHO, 2 )
C
C*C*RLH ELSE
C
C*C*RLH LRHO = PROPS( COEFF, EXPO, TNODE, IRHO )
C
C*C*RLH END IF
C
C*C*RLH IF( IPERTR .EQ. 0 ) THEN
C
C............................................................................
! Evaluate at temperature T
!
C*C*RLH CT = LCP * CVOL(ICPNT) * LRHO
C
Main Index
492 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 493
ULIBFOR Contents - Example User-Supplied Subroutines
C S U B R O U T I N E U F N S H D #
C #
C############################################################################
C
SUBROUTINE UFNSHD
C
C............................................................................
C
C UFNSHD --> Called at the completion of a solution cycle when
C crunch is going to be exited.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C............................................................................
C
RETURN
END
C
C
C
C############################################################################
C #
C PATRAN Customers May Modify This Routine In Any Manner They See Fit. #
C However, It Is The Customer's Responsibility To Maintain Any Such #
C Modifications. PDA Engineering Will Not Be Responsible For The #
C Consequences Incurred Due To The Modification Of This Routine. #
C #
C############################################################################
C #
C S U B R O U T I N E U H V A L #
C #
C############################################################################
C
SUBROUTINE UHVAL( ICFIG, IRESIS, COEFF, EXPO, JPROP, GP, T1, T2,
$ GVALH, Q, LOGP, J1, J2, J3, J4, J6 )
C
C############################################################################
C
C This subroutine is meant to be used as an example routine for those
C hardy souls who feel the urge to write their own User-Coded
C convection configuration library.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C ARGUMENTS:
C
C icfig --> configuration type of resistor
C iresis --> convective resistor i.d. number
C coeff --> material property data array
C expo --> material property data array
C jprop --> list of MPID numbers assigned to convective resistors
C gp --> list of geometric property data assigned to
C convective resistors
C t1 --> temperature of node #1 of the convective resistor
C (in degrees ICCALC)
C t2 --> temperature of node #2 of the convective resistor
C (also in degrees ICCALC)
C gvalh --> "conductance" of the resistor ( product of h * Area )
C q --> heat flow from node 1 to node 2
C logp --> resistor data print flag. if .true., resistor data
Main Index
494 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 495
ULIBFOR Contents - Example User-Supplied Subroutines
C
C*C DOUBLE PRECISION AREA, RHO, MU, K, CP, EXPAN, TBAR, TFILM,
C*C $ DTEMP, G, L, PR, RA, HLOW, RAL, HHIGH
C*C DOUBLE PRECISION PROPS
C*C
C*C EXTERNAL PROPS
C
C############################################################################
C
C Set up the logic to choose between user-supplied configurations
C 1000, 1001, and 1002. The computed go-to's are frequently
C significantly faster than nested if-then-else structures
C for large lists. The computed go-to structure below may
C easily be expanded to handle many more configurations. The
C logic assumes that you have decided to use user-supplied
C configurations 1000, 1001, and 1002. The first thing done
C is to subtract 999 from the ICFIG configuration value. Thus
C if ICFIG = 1000, CONFIG will be set to 1. The go-to will then
C branch to stmt number 1000. The other configurations are
C handled identically, as is obvious from the following coding.
C
C Note that while all coding is currently in this routine, it is easy
C (and better practice) to modularize each configuration into
C its own subroutine, e.g., UHVAL1, UHVAL2, etc., which would
C then by called by this master routine UHVAL. UHVAL would then
C contain nothing but the selection logical (the computed go-to)
C and calls to your list of routines.
C
C*C CONFIG = ICFIG - 999
C
C*C GO TO (1000,1001,1002),CONFIG
C
C############################################################################
C
C Set up the target statement label for configuration 1000.
C
C*C 1000 CONTINUE
C
C This configuration is going to be identical to QTRAN library
C configuration number 31, "Generic Constant H Value."
C
C Get the resistor surface area. This we have decided to store as
C Geometric Property number 1. Geometric properties for this
C resistor (number IRESIS) will be stored in the IRESIS'th row
C of the GP array. GP #1 will be in GP(IRESIS,1), GP #2 will
C be in GP(IRESIS,2), etc.
C
C*C AREA = GP(IRESIS,1)
C
C............................................................................
C
C Get the resistor h value. This we have decided to store as
C Geometric Property number 2.
C
C*C H = GP(IRESIS,2)
C
C............................................................................
C
C Compute the conductance. This is a requirement and its value will
C be returned to the calling routine.
C
C*C GVALH = H * AREA
C
C............................................................................
C
C Compute the heat transfer from node 1 to node 2. This is a requirement
C and its value will be returned to the calling routine.
C
Main Index
496 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C*C Q = GVALH * ( T1 - T2 )
C
C............................................................................
C
C Check to see if resistor data is being printed out. If not, return.
C If so, write out the h value and area.
C
C*C IF(.NOT.LOGP) RETURN
C
C............................................................................
C
C The following two QTRAN subroutines print out the h value and
C resistor area very easily.
C
C*C CALL HOUT( H )
C*C CALL AREAO( AREA )
C
C............................................................................
C
C Return to the calling routine.
C
C*C RETURN
C
C############################################################################
C
C Set up the target statement label for configuration 1001.
C
C*C 1001 CONTINUE
C
C This configuration will be identical to configuration number 29,
C "Generic Variable H value, H = H(TBAR)." For this property,
C it is assumed that the h value is to be taken directly from
C the material property specified by JPROP #1.
C
C First, get the TBAR value.
C
C*C TBAR = ( T1 + T2 ) / 2.0D+00
C
C............................................................................
C
C Second, get the JPROP #1 number. This will be stored in the JPROP
C array as JPROP(IRESIS,1). JPROP #2 would be stored in
C JPROP(IRESIS,2), and so on. Normally, MPID numbers are stored
C in the JPROP array. We will therefore call JPROP #1 by the
C name MPID.
C
C*C MPID = JPROP(IRESIS,1)
C
C............................................................................
C
C Third, get the h value. This is done by a call to QTRAN subroutine
C PROPS. PROPS is used to evaluate all of QTRAN's material
C property values. NOTE: If MPID is negative, subroutine PROPS
C will ignore it and will use the current TIME value as the
C evaluation argument. Since you are doing the coding,
C you may of course use any argument that you wish.
C
C*C H = PROPS( COEFF, EXPO, TBAR, MPID )
C
C............................................................................
C
C Fourth, get the surface area for the resistor. This is assumed to
C have been entered as GP #1, although you of course may enter
C it as any GP value that you wish (or get it from anywhere
C else that you are able to).
C
C*C AREA = GP(IRESIS,1)
C
Main Index
Chapter 11: User-Supplied Routines 497
ULIBFOR Contents - Example User-Supplied Subroutines
C............................................................................
C
C Compute the conductance ( h * Area ).
C
C*C GVALH = H * AREA
C
C............................................................................
C
C Compute the heat transferred from node 1 to node 2.
C
C*C Q = GVALH * ( T1 - T2 )
C
C............................................................................
C
C Check to see if resistor data is being printed out. If not, return.
C If so, write out the h value and area.
C
C*C IF(.NOT.LOGP) RETURN
C
C............................................................................
C
C The following two QTRAN subroutines print out the h value and
C resistor area very easily.
C
C*C CALL HOUT( H )
C*C CALL AREAO( AREA )
C
C............................................................................
C
C Return to the calling routine.
C
C*C RETURN
C
C############################################################################
C
C Set up the target statement label for configuration 1002.
C
C*C 1002 CONTINUE
C
C Now that we're done with the warm-up exercises, let's do a semi-serious
C convection configuration. Let's assume that:
C
C h = GP#5 { Rayleigh < 1.5E+05 }
C
C h = (GP#2) * Rayleigh**(GP#3) * Prandtl ** (GP#4) { otherwise }
C
C First, compute the necessary material properties.
C
C Assume: density = jprop #1
C viscosity = jprop #2
C coeffecient of expansion = jprop #3
C specific heat = jprop #4
C conductivity = jprop #5
C
C Compute the film temperature.
C
C*C TFILM = ( T1 + T2 ) * 0.5D+00
C
C Calculate the fluid properties. Since negative values for
C material properties would likely make our calculations
C blow up (as would a zero value), we will protect ourselves
C just a little bit and take the absolute value of the material
C properties and then fudge them by 1.0D-10 (the D exponent
C implies double precision).
C
C*C AREA = GP( IRESIS, 1 )
C
C*C RHO = DABS( PROPS( COEFF, EXPO, TFILM, JPROP(IRESIS,1)) ) +
Main Index
498 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C*C $ 1.D-10
C*C MU = DABS( PROPS( COEFF, EXPO, TFILM, JPROP(IRESIS,2)) ) +
C*C $ 1.D-10
C*C EXPAN = DABS( PROPS( COEFF, EXPO, TFILM, JPROP(IRESIS,3)) ) +
C*C $ 1.D-10
C*C CP = DABS( PROPS( COEFF, EXPO, TFILM, JPROP(IRESIS,4)) ) +
C*C $ 1.D-10
C*C K = DABS( PROPS( COEFF, EXPO, TFILM, JPROP(IRESIS,5)) ) +
C*C $ 1.D-10
C
C............................................................................
C
C Calculate the Prandtl number.
C
C*C PR = MU * CP / K
C
C............................................................................
C
C Calculate the Rayleigh number.
C
C First, get the gravitational constant entered as GP #6. Then get
C the characteristic length L used by the Rayleigh number.
C GP #7 will be the shortest distance between the resistor area
C and the surface edge whose boundary layer thickness is zero,
C and GP #8 will be the longest distance between the resistor
C area and the same edge. Note that adding GP #7 and GP #8 is
C one way of placing the resistor surface at the center of an
C artificially constructed effective characteristic length.
C This assumes that h(L) varies linearly from h(0) to h(L),
C and is a first order approximation only. Although not a
C particularly tremendous approximation, it does limit correctly
C when GP #7 = 0 and GP #8 = L and it is a whole lot better than
C simply assuming that h is constant across the whole convective
C surface. There are better ways, but this way is especially
C easy.
C
C*C G = GP(IRESIS,6)
C*C L = GP(IRESIS,7) + GP(IRESIS,8)
C
C Compute the temperature difference between the surface and the free
C stream fluid.
C
C*C DTEMP = DABS( T1 - T2 ) + 1.0D-10
C
C*C RA = DABS( G * EXPAN * ( RHO * RHO ) * ( L * L * L ) * DTEMP /
C*C $ ( MU * MU ) * PR ) + 1.0D-10
C
C............................................................................
C
C We now have a Rayleigh number. Check to see if we are in range of
C the first correlation or the second.
C NOTE: Most iterative codes (QTRAN included) do not appreciate step
C function discontinuities such as would be generated by a
C transition NUMBER. We will therefore use an arbitrary
C transition RANGE. What this means is that instead of using
C the transition number of 1.5E+05, we will smear the transition
C arbitrarily over the range of 1.3E+05 to 1.7E+05. Since step
C function discontinuities do not really occur anyway (laminar
C to turbulent transitions really do occur over a range) there is
C even some physical justification for this.
C
C First, calculate both the low range and the high range h values.
C
C*C HLOW = GP(IRESIS,5)
C
C , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C Limit the RA value to the range of the high correlation. This is done
Main Index
Chapter 11: User-Supplied Routines 499
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
500 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 501
ULIBFOR Contents - Example User-Supplied Subroutines
C
C............................................................................
C
C
C............................................................................
C
C
RETURN
END
C############################################################################
C #
C This file contains dummy subroutines that can be altered by the user #
C and included with the QTRAN thermal analysis module. These #
C routines are called at key entry points in the calculation #
C loop as well as during initialization phases, reading of the #
C input data file, etc. The routines included are: #
C #
C ROUTINES: #
C #
C UINPUT --> Called from QTRAN subroutine INPUT, this #
C subroutine may be used to read in customized #
C data not normally found in QTRAN's input data #
C file. It is called after QTRAN's normal input #
C data has been read in. #
C #
C UOUTPT --> Called from QTRAN subroutine QFLOW, this #
C subroutine may be used to print out customized #
C data immediately after the temperature data is #
C printed out for either transient or steady state #
C runs. UOUTPT data is printed out prior to the #
C resistor data. #
C #
C UINIT1 --> Called from QTRAN subroutine INIT1, this #
C subroutine may be used to initialize any system #
C arrays provided by the user. UINIT1 is called #
C prior to reading in any input data. #
C #
C UINIT2 --> Called from QTRAN subroutine INIT2, this #
C subroutine may be used to set up pointer tables #
C or anything else that may need to be done after #
C reading in the input data file(s). #
C #
C ULOOP1 --> Called from QTRAN subroutine RESET1, this #
C subroutine may be used to perform any necessary #
C housekeeping or calculations prior to beginning #
C a steady state run or a transient time step. #
C #
C ULOOP2 --> Called from QTRAN subroutine RESET2, this #
C subroutine may be used to perform any necessary #
C housekeeping or calculations prior to beginning #
C an iteration for either steady state or #
C transient runs. #
C #
C ULOOP3 --> Called from QTRAN subroutine CRUNCH, this #
C subroutine is called at the beginning of #
Main Index
502 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 503
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
504 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
C PARAMETER ( MAXBLK = 100 )
C
C DOUBLE PRECISION UA1, UA2, UA3
C
C COMMON / UB1 / UA1( MAXBLK )
C COMMON / UB2 / UA2( MAXBLK )
C COMMON / UB3 / UA3( MAXBLK )
C
C INTEGER I
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C Read in MAXBLK lines of UA1, UA2, and UA3 data.
C
C DO 1 I=1,MAXBLK
C READ( IINU, 2, ERR=900, END=999 ) UA1(I), UA2(I), UA3(I)
C 2 FORMAT( 3G20.10 )
C LNUM = LNUM + 1
C 1 CONTINUE
C
C Return to the calling routine.
C
C RETURN
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C 900 CONTINUE
C
C This section would be for when a format error was encountered.
C Write out an error message and quit.
C
C WRITE( IOU, 901 ) LNUM
C
C 901 FORMAT(//' ***>>> ERROR <<<***'//
C $' An error has occurred while reading in data for User-Supplied'/
C $' subroutine UINPUT. The error occurred on line number',I10,'.'/
C $/' ***>>> EXECUTION TERMINATING <<<***'//)
C
C CALL EXITQ
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C 999 CONTINUE
C
C This section would be for when an unexpected end-of-file occurred
C while trying to read in the data. Write out an error message
C and quit.
C
C WRITE( IOU, 998 ) LNUM
C WRITE( IOU, 998 ) LNUM
C
C 998 FORMAT(//' ***>>> ERROR <<<***'//
C $' An unexpected END-OF-FILE occurred while reading in data in'/
C $' User-Supplied subroutine UINPUT. The error occurred on line'/
C $' number',I10,'.'//' ***>>> EXECUTION TERMINATING <<<***'//)
C
C CALL EXITQ
C
C............................................................................
C
END
C
C############################################################################
C #
C S U B R O U T I N E U L O O P 1 #
C #
C############################################################################
Main Index
Chapter 11: User-Supplied Routines 505
ULIBFOR Contents - Example User-Supplied Subroutines
C
SUBROUTINE ULOOP1( COEFF, EXPO )
C
C............................................................................
C
C ULOOP1 --> Called from QTRAN subroutine RESET1, this
C subroutine may be used to perform any necessary
C housekeeping or calculations prior to beginning
C a steady state run or a transient time step.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
C Declare the arguments
C
DOUBLE PRECISION COEFF( J3, J4 ), EXPO( J3, J4 )
C
C############################################################################
C
C
C............................................................................
C
C
C............................................................................
C
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U L O O P 2 #
C #
C############################################################################
C
SUBROUTINE ULOOP2( COEFF, EXPO )
C
C............................................................................
C
C ULOOP2 --> Called from QTRAN subroutine RESET2, this
C subroutine may be used to perform any necessary
C housekeeping or calculations prior to beginning
Main Index
506 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 507
ULIBFOR Contents - Example User-Supplied Subroutines
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
C Declare the arguments
C
DOUBLE PRECISION COEFF( J3, J4 ), EXPO( J3, J4 )
C
C############################################################################
C
C
C............................................................................
C
C
C............................................................................
C
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U L O O P 4 #
C #
C############################################################################
C
SUBROUTINE ULOOP4( COEFF, EXPO )
C
C............................................................................
C
C ULOOP4 --> Called from QTRAN subroutine CRUNCH, this
C subroutine is called at the end of calculations
C for each node for each iteration immediately
C after the temperature for that node has been
C updated.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
Main Index
508 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 509
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
510 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 511
ULIBFOR Contents - Example User-Supplied Subroutines
C############################################################################
C
C
C............................................................................
C
C............................................................................
C
RETURN
END
C If greater, adjust TMAX30.
C
C*C TMAX30 = MAX( TEMPS(NODE), TMAX30 )
C
C If the maximum temperature is greater than or equal to 1000,
C set the microfunction value to 723.15.
C
C*C IF( TMAX30 .GE. 1000.0 ) VAL = 723.15
C
C*C ENDIF
C
C############################################################################
C
RETURN
END
C
C
C############################################################################
C #
C S U B R O U T I N E U M C R P R #
C #
C############################################################################
C
SUBROUTINE UMCRPR( X, MICRO, IFUNC, VAL, P, TX, TY, COEFF, EXPO )
C
C############################################################################
C
C this subroutine calculates the microfunction value and returns it
C in argument "val" for microfunction "micro". The evaluation
C option is passed to UMICRO as IFUNC. X is the independent
C variable specified by the calling macro function.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare the arguments.
C
INCLUDE 'common.dims'
C
INTEGER MICRO, IFUNC
C
DOUBLE PRECISION VAL, X
DOUBLE PRECISION P( J7, J8 ), TX( J9, J10 ), TY( J9, J10 )
DOUBLE PRECISION COEFF( J3, J4 ), EXPO( J3, J4 )
C*C DOUBLE PRECISION PROPS
C*C
C*C EXTERNAL PROPS
C
C############################################################################
C
C This routine is the same as UMICRO except the arguments have been
C added that allow the user to access material properties in
C addition to the micro functions. The following is an example of
C a call to properties. The user will have to figure out how to
C acquire the proper MPID's.
C
Main Index
512 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 513
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
514 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
C Check for node 30.
C
C*C ELSE IF( NODEA .LE. 30 ) THEN
C
C Check the node's temperature against it's maximum temperature.
C If greater, adjust TMAX30.
C
C*C TMAX30 = MAX( TEMPS(NODE), TMAX30 )
C
C If the maximum temperature is greater than or equal to 1000,
C set the microfunction value to 723.15.
C
C*C IF( TMAX30 .GE. 1000.0 ) VAL = 723.15
C
C*C ENDIF
C
C############################################################################
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U M I C R O #
C #
C############################################################################
C
SUBROUTINE UMICRO( X, MICRO, IFUNC, VAL )
C
C############################################################################
C
C this subroutine calculates the microfunction value and returns it
C in argument "val" for microfunction "micro". The evaluation
C option is passed to UMICRO as IFUNC. X is the independent
C variable specified by the calling macro function.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare the arguments.
C
INTEGER MICRO, IFUNC
C
DOUBLE PRECISION VAL, X
C
C############################################################################
C
C You may fill this area in with any computational algorithm that you
C desire. If you wish access to QTRAN's arrays for some reason,
C I suggest that you look at QTRAN's main module and reference
C these arrays through the common blocks set up in the main
C module. This should prove rather trivial. Note that the node
C number that this microfunction is going to be applied to is
C available as:
C
C Node_number = IALIAS(NODE),
C where Node_number will be the number that you used in the input
C data file. The value of NODE is actually QTRAN's internal
C reference to the packed node numbers stored in IALIAS.
C For example, suppose that the 23rd node number defined was
C node number 10070. Then IALIAS(23) will contain the value
C of 10070. For internal computational purposes for QTRAN,
C this is NODE 23. The value of the NODE being processed when
C this microfunction is called is available through the loop
Main Index
Chapter 11: User-Supplied Routines 515
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
516 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C*C
C*C INTEGER NODEA, NODE1, NODE2
C*C
C*C COMMON / LOCAL1 / TMAX15, TMAX30
C
C............................................................................
C
C Get the node number that the microfunction is applied to.
C
C*C TMAX15 = 15.0
C*C TMAX30 = 30.0
C*C NODNUM = ABS( IALIAS( NODE ) )
C*C IF( KTMAC .GT. 0 ) THEN
C
C TEMPERATURE MICRO FUNCTION IS DEFINED, GET NODES FROM THE IFLIST ARRAY
C
C*C NODEA = IFLIST( KTMAC, 1)
C*C NODE1 = IFLIST( KTMAC, 3)
C*C NODE2 = IFLIST( KTMAC, 4)
C*C ELSE IF( KQMAC .GT. 0 ) THEN
C*C NODEA = ITLIST( KTMAC, 1)
C*C NODE1 = ITLIST( KTMAC, 3)
C*C NODE2 = ITLIST( KTMAC, 4)
C*C END IF
C
C............................................................................
C
C Check for node 15.
C
C*C IF (NODEA .LE. 15 ) THEN
C
C Check the nodes temperature against it's maximum temperature.
C If greater, adjust TMAX15.
C
C*C TMAX15 = MAX( TEMPS (NODE ), TMAX15 )
C
C If the maximum temperature is greater than or equal to 1000,
C set the microfunction value to 100.
C
C*C IF( TMAX15 .GE. 1000.0 ) VAL = 100.0
C
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C Check for node 30.
C
C*C ELSE IF( NODEA .LE. 30 ) THEN
C
C Check the node's temperature against it's maximum temperature.
C If greater, adjust TMAX30.
C
C*C TMAX30 = MAX( TEMPS(NODE), TMAX30 )
C
C If the maximum temperature is greater than or equal to 1000,
C set the microfunction value to 723.15.
C
C*C IF( TMAX30 .GE. 1000.0 ) VAL = 723.15
C
C*C ENDIF
C
C############################################################################
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U O U T P T #
Main Index
Chapter 11: User-Supplied Routines 517
ULIBFOR Contents - Example User-Supplied Subroutines
C #
C############################################################################
C
SUBROUTINE UOUTPT( IO )
C
C............................................................................
C
C UOUTPT --> Called from QTRAN subroutine QFLOW, this
C subroutine may be used to print out customized
C data immediately after the temperature data is
C printed out for either transient or steady state
C runs. UOUTPT data is printed out prior to the
C resistor data.
C
C ARGUMENT:
C IO --> logical unit number for QTRAN's output data file.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
INTEGER IO
C
C............................................................................
C
C Any write statements that you wish to use may be included in this
C section of the routine in ANSI standard Fortran.
C
C As with many of the user-supplied routines, the main method of
C communicating between your user-supplied routines is through
C user-specified common blocks. For example, suppose the
C array UA1 contains results data from other user-coded
C subroutines. You will have to have built a common block
C containing UA1 already in your other routines. Assuming
C that this common block is called UB1 (similar to the example
C common block for subroutine UINPUT), the remainder of this
C example subroutine (which is commented out) shows an example
C of how your might go about printing the array data out.
C
C............................................................................
C
C Declare the example common block and array.
C
C INTEGER MAXBLK
C
C PARAMETER ( MAXBLK = 100 )
C
C DOUBLE PRECISION UA1
C
C COMMON / UB1 / UA1( MAXBLK )
C
C INTEGER I
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C Write out MAXBLK lines of UA1 data.
C
C WRITE( IO, 1 )
C 1 FORMAT( '1USER-SUPPLIED ARRAY UA1 DATA' /
C $ ' ----------------------------' //
C $11X, 'I', 14X, 'UA1(I)' /
C $11X, '-', 14X, '------' )
C
C DO 2 I = 1, MAXBLK
C WRITE( IO, 3 ) I, UA1( I )
C 3 FORMAT( 1X, I10, 1PD20.10 )
Main Index
518 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C 2 CONTINUE
C
C , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
C
C Return to the calling routine.
C
C RETURN
C
C............................................................................
C
END
C
C############################################################################
C #
C S U B R O U T I N E U P C P A C #
C #
C############################################################################
C
SUBROUTINE UPCPAC( ICPNT, OT, T, TPHASE, QPHASE, COEFF,
$ EXPO, CVOL, ICP, IRHO, C, IPHASE, QPHRHV )
C
C............................................................................
C
C this subroutine performs any necessary phase change energy balance
C calculations.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C > > > > > MODIFICATION HISTORY < < < < <
C
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
C Declare variable in call list
C
INTEGER IPHASE
INTEGER ICPNT
INTEGER ICP
INTEGER IRHO
C
double_precision TPHASE
Main Index
Chapter 11: User-Supplied Routines 519
ULIBFOR Contents - Example User-Supplied Subroutines
double_precision OT
double_precision T
double_precision QPHASE
double_precision C
C
C real arrays.
C
double_precision CVOL(*)
double_precision COEFF(J3,J4)
double_precision EXPO(J3,J4)
double_precision QPHRHV
C
C****************************************************************************
C
C Declare external functions
C
double_precision PROPS, CPEVAL
EXTERNAL PROPS, CPEVAL
C
C############################################################################
C
C local variables.
C
C*C*RLH double_precision TDIFF
C*C*RLH double_precision T12
C*C*RLH double_precision T23
C*C*RLH double_precision Q1
C*C*RLH double_precision Q2
C*C*RLH double_precision Q3
C*C*RLH double_precision TP2
C*C*RLH double_precision TP3
C*C*RLH double_precision FRAC
C*C*RLH double_precision TBAR
C*C*RLH double_precision TPCBM
C*C*RLH double_precision TPCBP
C
C############################################################################
C
C *---------------------------*
C | +|
C | + |
C | + |
C t | + |
C e | +++++++++++++ |
C m | +############# 3 |
C p | + ############# |
C | + #### #### |
C | + #### 2 #### |
C | + #### #### |
C | + 1 ############# |
C | + ############# |
C *---------------------------*
C
C energy
C
C----------------------------------------------------------------------------
CC
C Define the temperature at the beginning and end of the phase change
C
C*C*RLH TPCBM = TPHASE - PCBAND
C*C*RLH TPCBP = TPHASE + PCBAND
C
C check to see if going up or going down the t/e curve.
C if going down (iphase < 0), if going up (iphase >= 0).
C
C*C*RLH IF( IPHASE .LT. 0 ) THEN
C
C............................................................................
Main Index
520 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
C section 100 is for phase change going down the t/e curve. it assumes
C that ot is in region 2 or 3, and that t is in region 1 or 2
C of the t/e curve.
C
C begin the calculations for this section by calculating Q3,
C where Q3 is the capacitor stored energy between
C ot and tphase.
C
C*C*RLH TDIFF = TPCBP - OT
C
C*C*RLH IF( TDIFF .GT. 0.D+00 ) THEN
C
C*C*RLH TDIFF = 0.D+00
C*C*RLH Q3 = 0.0D+00
!
C*C*RLH ELSE
C
C*C*RLH T23 = OT + TDIFF * 0.5D+00
C*C*RLH Q3 = TDIFF * CVOL(ICPNT) *
C*C*RLH $ CPEVAL( OT, TPCBP, COEFF, EXPO, ICP ) *
C*C*RLH $ PROPS( COEFF, EXPO, T23, IRHO )
!
C*C*RLH END IF
C
C............................................................................
C
C calculate energy q2, which is the amount of latent heat energy
C being released through "freezing".
C
C*C*RLH TP2 = MIN( TPCBP, OT )
C*C*RLH TP3 = MAX( TPCBM, T )
C*C*RLH FRAC = ( TP3 - TP2 ) / ( PCBAND * 2.D+00 )
C*C*RLH QPHRHV = QPHASE * CVOL(ICPNT) *
C*C*RLH 1 PROPS( COEFF, EXPO, TPHASE, IRHO )
C*C*RLH Q2 = FRAC * QPHRHV
C
C Add the normal capacitance effects to Q2.
C
C*C*RLH TBAR = ( TP2 + TP3 ) * 0.5D+00
C*C*RLH Q2 = Q2 + ( TP3 - TP2 ) * CVOL(ICPNT) *
C*C*RLH $ CPEVAL( TP2, TP3, COEFF, EXPO, ICP ) *
C*C*RLH $ PROPS( COEFF, EXPO, TBAR, IRHO )
C
C............................................................................
C
C calculate the energy q1, which is the amount of energy stored
C between t and tphase.
C
C*C*RLH TDIFF = T - TPCBM
C
C*C*RLH IF( TDIFF .GT. 0.D+00 ) THEN
C
C*C*RLH TDIFF = 0.D+00
C*C*RLH Q1 = 0.0D+00
!
C*C*RLH ELSE
C
C*C*RLH T12 = T - TDIFF * 0.5D+00
C*C*RLH Q1 = TDIFF * CVOL(ICPNT) *
C*C*RLH $ CPEVAL( TPCBM, T, COEFF, EXPO, ICP ) *
C*C*RLH $ PROPS( COEFF, EXPO, T12, IRHO )
C
C*C*RLH END IF
C
C............................................................................
C
C all the potential capacitance effects have now been computed.
Main Index
Chapter 11: User-Supplied Routines 521
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
522 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
Chapter 11: User-Supplied Routines 523
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
524 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
C############################################################################
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U P R O P #
C #
C############################################################################
C
SUBROUTINE UPROP( PROP, X, COEFF, EXPO, IPMPID )
C
C############################################################################
C
C This subroutine can be modified by the user for the express purpose
C of supplying special-coded user-supplied material properties
C that may be too exotic to be handled by QTRAN's normal
C material property library functions. This routine is called
C by QTRAN whenever a material property has been defined with
C an evaluation option of U (IEVAL parameter in Section 5.3.1 of
C the input data file).
C
C Arguments:
C
C PROP --> value of the material property to be returned
C to QTRAN for use in calculations.
C
C X --> Temperature normally used to evaluate
C the material properties, e.g., temperature of
C a node or average temperature of a conductive
C resistor.
C
C COEFF()--> Array of MDATA1 values. For this material
C property, the MATA1(i) values are stored as
C COEFF(IPMPID,i+1). COEFF(IPMPID,1) contains
C the number of MDATA1/MDATA2 data pairs.
C
C EXPO() --> Array of MDATA2 values. For this material
C property, the MATA2(i) values are stored as
C EXPO(IPMPID,i+1). EXPO(IPMPID,1) stores an
C evaluation code, which is used to determine
C whether the material property is a constant,
C a linear data table, etc. (from subroutine
C UPROP, this code always specifies "user-supplied").
C
C IPMPID --> packed material property i.d. This is not the same
C as the MPID number normally entered in Section 5.3.1
C of the input data file. IPMPID here corresponds to
C the IPMPID'th material property that was defined in
C Section 5.3.1. To retrieve the MPID number that you
C gave in Section 5.3.1 for this material property,
C you must reference the MID array in the following
C manner:
C
C COMMON / IA45 / MID(1)
C MPID = MID( IPMPID )
C
C You will then have the correct MPID number for
C the IPMPID'th material property. It should be noted
C that the MPID number is normally not needed for
C anything here, although you might wish to have
C access to it in the event that you set up some
C error message routines.
C
C############################################################################
C
Main Index
Chapter 11: User-Supplied Routines 525
ULIBFOR Contents - Example User-Supplied Subroutines
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.blk file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C
C Declare the arguments and local variables.
C
DOUBLE PRECISION PROP, X, COEFF( J3, J4 ), EXPO( J3, J4 )
C
INTEGER IPMPID
C
C*C*RLH INTEGER MPID
C*C*RLH INTEGER MID
C
C*C*RLH DOUBLE PRECISION TIME
C
C*C*RLH COMMON / IA45 / MID(1)
C
C*C*RLH COMMON / RB1 / TIME
C
C############################################################################
C
C The remainder of this subroutine shows an EXAMPLE ONLY of what you
C might do if you wished one or more custom material properties.
C
C Let us suppose that the material property that you wish to define is a
C mix of time and temperature.
C
C############################################################################
C
C This property section shows how to build a material property
C evaluation that is a mix of both temperature and time.
C Suppose that the form of the material property to be
C defined is as follows:
C
C Property(Temp,Time) = { A + B * Temp } * { C + D * Time }
C
C The following coding accomplishes this. The assumption is that:
C
C A = 1.0
C B = 2.0
C C = 3.0
C D = -2.0
C
C*C PROP = ( 1.0D+00 + 2.0D+00 * X ) *
C*C $ ( 3.0D+00 - 2.0D+00 * TIME )
Main Index
526 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C
C NOTE: The value of TIME is passed to this routine via
C a named COMMON block which is inserted at the
C beginning of this routine. The block's name is:
C
C############################################################################
C
! This is an example of how to use user routines to modify resistor values
! User material properties have to be used to flag which resistor or
! capacitors are to be modified by the user.
!
C*C*RLH MPID = MID( IPMPID )
!
C*C*RLH IF( MPID .EQ. 203101 ) THEN
! Silver conductivity MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 203104 ) THEN
! Silver density MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 203105 ) THEN
! Silver specific heat MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 203117 ) THEN
! Silver Emissivity
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 270701 ) THEN
! Flint Glass Conductivity MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 270704 ) THEN
! Flint Glass Density MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 270705 ) THEN
! Flint Glass Specific Heat MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 270717 ) THEN
! Flint Glass Emissivity
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 303101 ) THEN
! Silver conductivity MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 303104 ) THEN
! Silver density MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 303105 ) THEN
! Silver specific heat MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 303117 ) THEN
! Silver Emissivity
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 370701 ) THEN
! Flint Glass Conductivity MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 370704 ) THEN
! Flint Glass Density MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 370705 ) THEN
! Flint Glass Specific Heat MKS units
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH ELSE IF( MPID .EQ. 370717 ) THEN
! Flint Glass Emissivity
C*C*RLH PROP = COEFF( IPMPID, 2 )
C*C*RLH END IF
!
RETURN
C
C############################################################################
C
C As you can see, probably the hardest part of this whole exercise was
Main Index
Chapter 11: User-Supplied Routines 527
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
528 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C define call list variables
C
INTEGER NRAD
C
DOUBLE PRECISION COEFF( J3, J4 ), EXPO( J3, J4 )
DOUBLE PRECISION GVAL
DOUBLE PRECISION QGRAY
DOUBLE PRECISION TT1
DOUBLE PRECISION TT2
DOUBLE PRECISION TT3
DOUBLE PRECISION T1SAVE
DOUBLE PRECISION T2SAVE
C
C############################################################################
C
C Declare the common block variables
C
C
C############################################################################
C
C*C*RLH INTEGER MID
C*C*RLH INTEGER IO
C*C*RLH INTEGER IGTYPE
C*C*RLH INTEGER IGPROP
!
C*C*RLH LOGICAL LOGP
!
C*C*RLH DOUBLE PRECISION SBC
C*C*RLH DOUBLE PRECISION EMISS
C*C*RLH DOUBLE PRECISION TAU
C*C*RLH DOUBLE PRECISION GAREA
!!
C*C*RLH COMMON / IA14 / IGTYPE( 1 )
C*C*RLH COMMON / IA15 / IGPROP( 1 )
C*C*RLH COMMON / IA45 / MID( 1 )
C
C*C*RLH COMMON / IB33 / IO
!
C*C*RLH COMMON / LB3 / LOGP
!
C*C*RLH COMMON / RA23 / GAREA( 1 )
!
Main Index
Chapter 11: User-Supplied Routines 529
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
530 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C############################################################################
C #
C S U B R O U T I N E U R S T R T #
C #
C############################################################################
C
SUBROUTINE URSTRT
C
C............................................................................
C
C URSTRT --> Called from QTRAN subroutine GETRST, this
C subroutine is called if QTRAN is resuming
C execution from a restart file.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C
C............................................................................
C
C
C............................................................................
C
C
RETURN
END
C
C############################################################################
C #
C S U B R O U T I N E U S O L #
C #
C############################################################################
C
SUBROUTINE USOL( T1RH, T2RH, T3RH, JPROP, JTYPE, RHNPNT, T1RC,
$ T2RC, RCPROP, RCNPNT, T1RR, T2RR, T3RR, IGTYPE, IGPROP, GSFACT,
$ GAREA, RRNPNT, QCARD, IFLIST, QIPPNT, ITLIST, FIXNUM, FIXVAL,
$ TFIX, CPROP, CRHO, RCN, RHN, RRN, QIP, ALPHA, IALIAS, GP, COEFF,
$ EXPO, RCAL, P, TX, TY, SETTIM, PIDSET, PIDPAR, PIDID, CVOL,
$ TEMPS, QVECT, OTEMPS, T1RW, T2RW, T3RW, IWTYPE, IWPROP, RWNPNT,
$ RWN, WSPROP, WLPROP, SFACTR, WAREA, T1RF, T2RF, ICPFLO, RFN,
$ RFNPNT, RMDOT, DTMAXA, PRINTA, T1CAPS, CNPNT, CN, MID, PID,
$ MFID, QMFACT, TMFACT, QBASE, GDIST, WDIST,
$ TERROR, GVALCA, QINMAC, AVNODH, FVAR, GUMTRX, ICNTRL,
$ INDRLX, IPRLXC, RLXTBS, RLXTBT, RELAXV, EFACTB, RELAXM, RERROR,
$ IRRLXC,
$ T1RP, T2RP, PTYPE, PPROP, RPN, RPNPNT, IMLIST, MIP,
$ MIPPNT, IPLIST, PFIX, PALIAS, PIALAS, HIALAS,
$ PGP, MMFACT, PMFACT, MDBASE, PRHOE, VELOCP, PRHO,
$ PRESS, OPRESS, MDOTP, MDOTND, HYCCE, DIFHED, QMDOTP, QBASEF )
C
C############################################################################
C #
C This subroutine contains solution option 1000. #
C #
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.blk file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
Main Index
Chapter 11: User-Supplied Routines 531
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
532 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
INTEGER IALIAS(*)
INTEGER MID(*)
INTEGER PID(*)
INTEGER MFID(*)
INTEGER IGTYPE(*)
INTEGER IGPROP(*)
INTEGER INDRLX( MAXT )
INTEGER IPRLXC( MAXT )
INTEGER IRRLXC( MAXT )
C
C Hydraulic variables
C
INTEGER T1RP ( * )
INTEGER T2RP ( * )
INTEGER PTYPE ( * )
INTEGER PPROP ( J44, J46 )
INTEGER RPN ( * )
INTEGER RPNPNT( * )
INTEGER IMLIST( J48, J49 )
INTEGER MIP ( * )
INTEGER MIPPNT( * )
INTEGER IPLIST( J50, J51 )
INTEGER PFIX ( * )
INTEGER PALIAS( * )
INTEGER PIALAS( * )
INTEGER HIALAS( * )
C
C............................................................................
C
C real arrays.
C
DOUBLE PRECISION ALPHA(*)
DOUBLE PRECISION GP( J1, J6 )
DOUBLE PRECISION COEFF( J3, J4 )
DOUBLE PRECISION EXPO( J3, J4 )
DOUBLE PRECISION RCAL(*)
DOUBLE PRECISION P(J7,J8)
DOUBLE PRECISION TX( J9, J10 )
DOUBLE PRECISION TY( J9, J10 )
DOUBLE PRECISION GSFACT(*)
DOUBLE PRECISION GAREA(*)
DOUBLE PRECISION SETTIM(*)
DOUBLE PRECISION WSPROP(*)
DOUBLE PRECISION WLPROP(*)
DOUBLE PRECISION SFACTR(*)
DOUBLE PRECISION WAREA(*)
DOUBLE PRECISION CVOL(*)
DOUBLE PRECISION TEMPS(*)
DOUBLE PRECISION QVECT(*)
DOUBLE PRECISION OTEMPS(*)
DOUBLE PRECISION RMDOT(*)
DOUBLE PRECISION DTMAXA( J32, J33 )
DOUBLE PRECISION PRINTA( J34, J35 )
DOUBLE PRECISION PIDSET( J22, J23 )
DOUBLE PRECISION QMFACT( J17 )
DOUBLE PRECISION TMFACT( J18 )
DOUBLE PRECISION QBASE( MAXT )
DOUBLE PRECISION GDIST(*)
DOUBLE PRECISION WDIST(*)
DOUBLE PRECISION TERROR (MAXT, J27 )
DOUBLE PRECISION GVALCA(*)
DOUBLE PRECISION QINMAC( MAXT )
DOUBLE PRECISION AVNODH( MAXT )
DOUBLE PRECISION FVAR( MAXT, * )
DOUBLE PRECISION GUMTRX( M1, M1 )
DOUBLE PRECISION RLXTBS( J39, J40)
DOUBLE PRECISION RLXTBT( J39, J40)
DOUBLE PRECISION RELAXV( MAXT )
Main Index
Chapter 11: User-Supplied Routines 533
ULIBFOR Contents - Example User-Supplied Subroutines
Main Index
534 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
ULIBFOR Contents - Example User-Supplied Subroutines
C supplied by PATRAN.
C
C The Gval and QGRAY values must be calculated and passed back to the
C calling routine.
C
C############################################################################
C
IMPLICIT NONE
C
C############################################################################
C
C Declare problem dimensions and common block where they are defined.
C This is taken from the common.dims file.
C
INTEGER J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
COMMON /DIMS/ J1, J2, J3, J4, J5, J6, J7, J8, J9,
$ J10, J11, J12, J13, J14, J15, J16, J17, J18,
$ J19, J20, J21, J22, J23, J24, J25, J26, J27,
$ J28, J29, J30, J31, J32, J33, J34, J35, J36,
$ J37, J38, J39, J40, J41, J42, J43,
$ J44, J45, J46, J47, J48, J49, J50, J51, J52,
$ MAXT, MAXTNC, MAXTNH, MAXTNR, MAXTNW, MAXTQN,
$ MAXTNF, M1, MAXP
C
C############################################################################
C define call list variables
C
DOUBLE PRECISION TT1
DOUBLE PRECISION TT2
DOUBLE PRECISION TT3
DOUBLE PRECISION T1SAVE
DOUBLE PRECISION T2SAVE
DOUBLE PRECISION F1
DOUBLE PRECISION F2
DOUBLE PRECISION GVAL
DOUBLE PRECISION QWAVE
DOUBLE PRECISION COEFF( J3, J4 )
DOUBLE PRECISION EXPO( J3, J4 )
C
INTEGER NWRAD
C
C############################################################################
C
C Declare the common variables
C
C*C*RLH DOUBLE PRECISION WAREA
C
C*C*RLH DOUBLE PRECISION SBC
C
C*C*RLH INTEGER IWTYPE
C*C*RLH INTEGER IWPROP
C
C*C*RLH COMMON / IA29 / IWTYPE( 1 )
C*C*RLH COMMON / IA30 / IWPROP( 1 )
C
C*C*RLH COMMON / RA14 / WAREA( 1 )
C
C*C*RLH COMMON / RB22 / SBC
C
C############################################################################
Main Index
Chapter 11: User-Supplied Routines 535
ULIBFOR Contents - Example User-Supplied Subroutines
C*C*RLH ENDIF
C
C............................................................................
C
C calculate the heat transmitted from node 1 to 2.
C
C*C*RLH GVAL = SBC * ( EMISS * WAREA(NWRAD) ) / ( 1.D+00 - EMISS ) *
C*C*RLH $ ( F1 * F1 * TT1 * TT1 + F2 * F2 * TT2 * TT2 ) *
C*C*RLH $ ABS( F1 * TT1 + F2 * TT2 )
C
C*C*RLH QWAVE = GVAL * ( F1 * TT1 - F2 * TT2 )
C
C*C*RLH ENDIF
C
C$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
C
RETURN
C
C############################################################################
C
END
Main Index
536 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example User-Supplied Routines
Main Index
Chapter 11: User-Supplied Routines 537
Example User-Supplied Routines
Main Index
538 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example User-Supplied Routines
Main Index
Chapter 11: User-Supplied Routines 539
Example User-Supplied Routines
Main Index
540 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example User-Supplied Routines
Main Index
Chapter 11: User-Supplied Routines 541
Example User-Supplied Routines
Main Index
542 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example User-Supplied Routines
Main Index
Chapter 11: User-Supplied Routines 543
Example User-Supplied Routines
Main Index
544 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example User-Supplied Routines
Main Index
Chapter 11: User-Supplied Routines 545
QTRAN Arrays
QTRAN Arrays
The following is a list of the QTRAN data arrays to which user-supplied subroutines may require access.
The variable dimensions for these arrays (e.g., J1, J2, ..., MAXT, etc.) are stored in the DIMS common
block and may be found in the COMMONBLK file.
The following arrays are arranged in their order of common block declarations. The IA common blocks
are Integer Array common blocks, while the RA common blocks are Real Arrays.
Note: While the documented array structures are valid for QTRAN, recognize that QTRAN is still
a living code, and as such the array structures may change from time to time. Also recognize
that the publishing of the array structures does not obligate our Hot Line staff to help with
basic Fortran language questions. Further recognize that when the basic QTRAN logic is
altered with the introduction of user software, it makes support extremely difficult if not
impossible. The MSC.Software Corporation will not assume responsibility for software
which has been linked to user-supplied subroutines.
Main Index
546 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
Main Index
Chapter 11: User-Supplied Routines 547
QTRAN Arrays
Main Index
548 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
Main Index
Chapter 11: User-Supplied Routines 549
QTRAN Arrays
Main Index
550 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
Main Index
Chapter 11: User-Supplied Routines 551
QTRAN Arrays
INTEGER IALIAS(MAXT)IA25
IALIAS(N) contains the model’s node number for QTRAN’s internal node number N. The sign of
IALIAS(N) determines whether the node’s temperature will be printed out in the QOUTDAT file, with
a negative sign indicating that it will be printed out and a positive sign indicating that it will not be printed
out.
This whole process of “aliased” node numbers is necessary if a code is to allow nonsequential node
numbering in the model. QTRAN essentially looks at the node numbers that are used in the model and
then condenses out any node numbers which are not used in the model that lie between 1 and the largest
node number specified. This adds some unfortunate complexity to the coding, but it allows more
flexibility in modeling without incurring unacceptable performance costs.
A useful QTRAN subroutine for determining a QTRAN internal node number for a given model node
number is subroutine GETNUM. The calling sequence for GETNUM is as follows:
CALL GETNUM( YNODE, QNODE, IALIAS, NTEMPS, MATCH )
where:
Main Index
552 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
T1RC(K) and T2RC(K) contain QTRAN’s internal node numbers for conductive resistor K’s nodes 1
and 2. RCPROP(K) contains trains internal MPID number for thermal conductivity for resistor K, and
RCAL(K) contains the area/length ratio for conductive resistor K. If solution option 1 (SOL = 1 in the
QINDAT file) is being used, GVALCA(K) contains the conductance (kA/L) for resistor K.
RCN(N) contains the number of conductive resistors associated with QTRAN’s internal node N.
RCNPNT is a pointer array used by QTRAN to determine which conductive resistors are associated with
a particular node, and is used in conjunction with the RCN array. If RCN(1) is 10, the first 10 elements
of the RCNPNT are conductive resistors which are associated with QTRAN internal node number 1. The
conductive resistors associated with QTRAN internal node number 2 (if any) would be contained in
RCNPNT(11) to RCNPNT(10+RCN(2)).
The QTRAN internal node numbers associated with convective resistor K are stored in T1RH(K),
T2RH(K), and T3RH(K), and the convective configuration (CFIG value) for convective resistor K is
Main Index
Chapter 11: User-Supplied Routines 553
QTRAN Arrays
stored in JTYPE(K). The GP values for convective resistor K are stored in GP(K,1) through GP(K,J6)
while the QTRAN internal MPID numbers for convective resistor K are stored in JPROP(K,1) through
JPROP(K,J2).
RHN(N) is the number of convective resistors associated with node N. The RHNPNT array interacts with
the RHN array in a manner similar to the conductive resistors and RCN/RCNPNT interactions.
The QTRAN internal node numbers associated with advective resistor K are stored in T1RF(K) and
T2RF(K). The QTRAN internal MPID numbers associated with specific heat and with variable mass
flow rate for advective resistor K are stored in ICPFLO(K,1) and ICPFLO(K,2), respectively. The
constant mass flow rate (or flow rate multiplier) associated with advective resistor K is stored in
RMDOT(K).
The RFN and RFNPNT arrays are analogous to the conductive resistor RCN and RCNPNT arrays.
The QTRAN internal node numbers associated with hydraulic resistor K are stored in T1RP(K) and
T2RP(K), and the fluid configuration (FCFIG value) for hydraulic resistor K is stored in PTYPE(K). The
GP values for hydraulic resistor K are stored in PGP(K,1) through PGP(K,J46) while the QTRAN
internal MPID numbers for hydraulic resistor K are stored in PPROP(K,1) through PPROP(K,J46).
Main Index
554 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
RPN(N) is the number of hydraulic resistors associated with node N. The RPNPNT array interacts with
the RPN array in a manner similar to the conductive resistors and RCN/RCNPNT interactions.
The hydraulic network introduces an additional network that is solved as a separate group of nodes with
its own solution procedure separate from the thermal network solution. This imposes some restriction on
the node definitions. All hydraulic nodes must be specified before the purely thermal nodes are specified,
but there is no restriction on how the nodes are to be numbered. As with gaps in the thermal nodes require
an aliasing array to relate user nodes numbers to internal node number, the same is needed for the fluid
nodes, plus index to relate internal node numbers to the internal thermal node numbers is required.
PALIAS(N) contains the model node number as specified by the user to the internal node number N.
PIALAS(N) contains the internal thermal node number corresponding to the internal fluid node number
N. HIALAS(N) contains the internal fluid node number corresponding to the internal thermal node
number N.
The QTRAN internal node numbers associated with gray radiative resistor K are stored in T1RR(K),
T2RR(K), and T3RR(K). The resistor subtype for gray radiative resistor K is stored in IGTYPE(K), while
the QTRAN internal MPID number associated with the resistor (for emissivity, transmissivity, or
extinction coefficient) is stored in IGPROP(K). The view factor distance (if any) is stored in GDIST(K),
the F value is stored in GSFACT(K), and the A value (if any) is stored in GAREA(K).
Main Index
Chapter 11: User-Supplied Routines 555
QTRAN Arrays
The RRN and RRNPNT arrays are analogous to the conductive resistor RCN and RCNPNT arrays.
The QTRAN internal node numbers associated with wavelength-dependent radiative resistor K are
stored in T1RW(K), T2RW(K), and T3RW(K). The resistor subtype for wavelength-dependent radiative
resistor K is stored in IWTYPE(K), while the QTRAN internal MPID number associated with the resistor
(for emissivity, transmissivity, or extinction coefficient) is stored in IWPROP(K). The view factor
distance (if any) is stored in WDIST(K), the F value is stored in SFACTR(K), and the A value (if any) is
stored in WAREA(K). The shortest and longest wavelengths associated with wavelength-dependent
radiative resistor K are stored in WSPROP(K) and WLPROP(K), respectively.
The RWN and RWNPNT arrays are analogous to the conductive resistor RCN and RCNPNT arrays.
Main Index
556 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
The QTRAN internal node number for capacitor K is stored in T1CAPS(K), while the QTRAN internal
specific heat, density, and phase change MPID numbers are stored in CPROP(K), CRHO(K), and
PIDID(K), respectively. The volume associated with capacitor K is stored in CVOL(K).
The CN and CNPNT arrays are analogous to conductive resistor arrays RCN and RCNPNT.
These arrays are used to store material property data if the MPID defined was NOT a phase change data
set (IEVAL not set to PH in the QINDAT file). For these MPID sets, QTRAN stores the MPID numbers
into the MID array in the order they appear in the QINDAT or MATDAT files. For QTRAN internal
nemophilas change MPID number K, the MPID which is defined for this material is stored in MID(K).
The MDATA1 and MDATA2 values for QTRAN internal MPID K are stored in COEFF(K,2) to
COEFF(K,J4) for MDATA1 and in EXPO(K,2) to EXPO(K,J4) for the MDATA2 values. COEFF(K,1)
is used to store the number of MDATA1/MDATA2 data pairs, while EXPO(K,1) is used to store a
numeric key for the evaluation option IEVAL. Specifically:
Main Index
Chapter 11: User-Supplied Routines 557
QTRAN Arrays
These arrays are used to store material property data if the MPID defined WAS a phase change data set
(IEVAL set to PH in the QINDAT file). For these MPID sets, QTRAN stores your MPID numbers into
the PID array in the order they appear in the QINDAT or MATDAT files. For QTRAN internal phase
change MPID number K, the MPID which is defined for this material is stored in PID(K).
The MDATA1 and MDATA2 values for QTRAN internal phase change MPID K are stored in
PIDSET(K,1) through PIDSET(K,J23). For phase change set K, the number of MDATA1/MDATA2
data pairs is stored in PIDPAR(K).
Main Index
558 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
Microfunction Arrays
INTEGER MFID(J14) IA47
MFID(K) contains the microfunction ID number (MFID) for the K'th microfunction which is defined in
the QINDAT or MICRODAT files.
QCARD(K,1) contains an argument code for the microfunction which specifies whether the
microfunction is to be a function of time, temperature, delta temperature, delta T4, or average
temperature. Values are 0, 1, 2, 3, and 4, respectively.
QCARD(K,2) stores the microfunction option number as per Microfunction Library (Ch. 10).
QCARD(K,3) contains the number of parameters or data pairs entered for MDATA1 and MDATA2.
QCARD(K,4) contains a row pointer L into the P or TX/TY arrays where the MDATA values for the
microfunction are stored.
For the K'th microfunction, L is stored in QCARD(K,4). The parameters MICDAT1-MICDAT4 are
stored in P(L,1) through P(L,4) for those microfunctions which use parameters. For tabular
microfunctions, the MICDAT1/MICDAT2 ordered pairs are stored in TX(L,2) -TX(L,J10) for
MICDAT1 values and TY(L,2)-TY(L,J10) for MICDAT2 values. TX(L,1) contains the number of
MDATA data pairs, and TY(L,1) is not used.
QMACROfunction Arrays
INTEGER IFLIST(J17,J16) IA17
For the K'th QMACROfunction, IFLIST(K,1) contains the QTRAN internal node number to which the
heat source is assigned.
IFLIST(K,2) contains the number of microfunctions used to build this QMACROfunction.
IFLIST(K,3) contains the T1 QTRAN internal node number.
Main Index
Chapter 11: User-Supplied Routines 559
QTRAN Arrays
MMACROfunction Arrays
INTEGER IMLIST(J48,J49) IA80
For the K'th MMACROfunction, IMLIST(K,1) contains the QTRAN internal node number to which the
fluid mass flow rate is assigned.
IMLIST(K,2) contains the number of microfunctions used to build this QMACROfunction.
IMLIST(K,3) contains the P1 QTRAN hydraulic internal node number.
IMLIST(K,4) contains the P2 QTRAN hydraulic internal node number.
IMLIST(5)-IPLIST( 4+IMLIST(K,2) ) contains the QTRAN internal microfunction ID's which are used
to build this MMACROfunction.
MMFACT(K) contains the scale factor for the K'th MMACROfunction.
MIP and MIPPNT are analogous to the conductive resistor RCN and RCNPNT arrays, respectively.
TMACROfunction Arrays
INTEGER ITLIST(J18,J19) IA19
For the K'th TMACROfunction, ITLIST(K,1) contains the QTRAN internal node number to which the
temperature source is assigned.
ITLIST(K,2) contains the number of microfunctions used to build this TMACROfunction.
ITLIST(K,3) contains the T1 QTRAN internal node number.
ITLIST(K,4) contains the T2 QTRAN internal node number.
ITLIST(5)-ITLIST( 4+ITLIST(K,2) ) contains the QTRAN internal microfunction IDs which are used to
build this TMACROfunction.
Main Index
560 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
PMACROfunction Arrays
INTEGER IPLIST(J50,J51) IA83
For the K'th MMACROfunction, IPLIST(K,1) contains the QTRAN internal node number to which the
temperature source is assigned.
IPLIST(K,2) contains the number of microfunctions used to build this MMACROfunction.
IPLIST(K,3) contains the P1 QTRAN internal hydraulic node number.
IPLIST(K,4) contains the P2 QTRAN internal node hydraulic number.
IPLIST(5)-IPLIST( 4+IPLIST(K,2) ) contains the QTRAN internal microfunction ID's which are used
to build this MMACROfunction.
PMFACT(K) contains the scale factor for the K'th MMACROfunction.
QBASE(N) is the constant nodal heat source value associated with QTRAN internal node number N.
Once read from the QINDAT file in subroutine INPUT4, it is never updated by QTRAN. However, it can
be modified by any of the User-Supplied subroutines.
MBASE(N) is the constant nodal net mass flow rate value associated with QTRAN internal node number
N. Once read from the QINDAT file in subroutine INPUT4, it is never updated by QTRAN. However, it
can be modified by any of the User-Supplied subroutines.
Main Index
Chapter 11: User-Supplied Routines 561
QTRAN Arrays
VELOCP is the average velocity at internal hydraulic node. PRHO is the average density at the internal
hydraulic node. OPRESS is pressure from the previous interaction at the internal hydraulic node. PRESS
is the current pressure at the internal hydraulic node. MDOTND is the net mass flow rate at the internal
hydraulic node.
These arrays define parameters that apply to the hydraulic elements rather than results at the node
locations. PRHOE is the average fluid density throughout an element. MDOTP is the mass flow rate of
fluid flowing in a given hydraulic element. HYCCE is the hydraulic conductance throughout a given
element. DIFHED is the difference in static head from one side of a hydraulic element to the other.
QMDOTP is the volumetric flow rate of the fluid flowing through a given element.
Main Index
562 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
TFIX(N) contains the fixed, not fixed, or TMACROfunction controlled code for node N. The values are
0: for not fixed, 1 for fixed, and 2 for TMACROfunction controlled.
The QINDAT CFIX information is stored in the FIXNUM, SETTIM, and FIXVAL arrays. For the K'th
CFIX data line in the QINDAT file, FIXNUM(K) contains the QTRAN internal node number whose
TFIX classification is being changed, SETTIM(K) is the time at which the change is to occur, and
FIXVAL(K) is the new TFIX control code (see TFIX above) which is 0, 1, or 2.
PFIX(N) contains the fixed or not fixed code for the internal hydraulic node N. The hydraulic fixed flag
operates on the fluid pressure. If a Hydraulic node is fixed, the pressure at that node is fixed.
OTEMPS(K) is the temperature of internal node number K at the beginning of a time step for transient
runs. It is not used for steady-state runs.
TEMPS(K) is the temperature of internal node number K for steady-state runs. It is also the temperature
at time t+dt (the end of the time step) for transient runs.
The temperatures stored in these arrays are in the temperature scale specified by the QINDAT parameter
ICCALC.
TERROR(N,1) through TERROR(N,J27) contains the iterative error for QTRAN internal node N for the
last J27 iterations. TERROR(N,1) is the most recent iterative error while TERROR(N,J27) is the least
recent iterative error. This array is used in conjunction with the EPSIT2 parameter for determining which
nodes should continue to be iterated upon.
Main Index
Chapter 11: User-Supplied Routines 563
QTRAN Arrays
QVECT(N) is the net nodal heat flow into QTRAN internal node number N, not including the heat flow
to/from the capacitors associated with node N. This value is updated in subroutine CCAPAC.
ALPHA(N) is the explicit stable time step associated with QTRAN internal node number N. It is updated
in subroutine CCAPAC.
DTMAXA is an array that is used to store the DTMAX adjustments. See QTRAN Run Control
Parameters and Node Number Declarations (Ch. 8). The DTMAXA data pairs from the QINDAT file are
stored in the DTMAXA array in the order in which they appear in the QINDAT file. DTMAXA(1,1)
contains the number of DTMAXA data pairs in the QINDAT file. DTMAXA(1,2) contains a pointer to
the next row of the DTMAXA array that will be used to adjust the DTMAX value. DTMAXA(K,1)
contains the new DTMAX values, while DTMAXA(K,2) contains the implementation times.
DTMXHA is an array that contains the time step increment for hydraulic solutions. When time gets to
the implementation time defined by DTMAXA(K,2), a new fluid time step DTMAXH is defined by
DTMXHA(K).
PRINTA is an array that is used to store the TPRINT adjustments. See QTRAN Run Control Parameters
and Node Number Declarations (Ch. 8). The PRINTA data pairs from the QINDAT file are stored in the
PRINTA array in the order in which they appear in the QINDAT file. PRINTA(1,1) contains the number
of PRINTA data pairs in the QINDAT file. PRINTA(1,2) contains a pointer to the next row of the
PRINTA array that will be used to adjust the TPRINT value. PRINTA(K,1) contains the new TPRINT
values, while PRINTA(K,2) contains the implementation times.
Main Index
564 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
This array stores the indexes of the node that are defined in the plot output block.
These array are in common block RA43 and contain the node locations in the global coordinate system.
The locations are packed in the same order that the nodes were defined in the node definition block.
Note that all three arrays are in the same named common block. This is the same as referencing the values
as a doubly dimensioned array XYZCRD( MAXT, 3 ). Since this type of array is loaded by column in
Fortran, the unit dimension for the array can not be used to reference the arrays. Either the MAXT value
must be input for the specific case being executed, another subroutine called where the MAXT argument
is included as one of the parameters passed and included in the declaration statement or only a single
dimensioned array is specified and the actual index is calculated. For example, if the single index is used,
the index would indicate the x location but MAXT and 2*MAXT would have to be added for the y and
z locations respectively.
Another point is that the radial dimension for axisymmetric translation is always in the XRCRDV and
the z-axis dimension is always in the YZCRDV arrays regardless of which plane was used to create the
model. Thus if a model was created in the zx plane with the z-axis being defined as the radial direction
all radial dimension would be in the XRCRDV array and the z-axis dimension which would have been
along the x-axis would be in the YZCRDV array.
Main Index
Chapter 11: User-Supplied Routines 565
QTRAN Arrays
These arrays contain information related to calculations and printout of the relaxation parameters. The
INDRLX, IPRLXC, and IRRLXC arrays are pointers that indicate the type of relaxation applied to a
given node and counters which indicate if the relaxation parameter is to be updated. IRLXGR keeps the
node IDs that have the greater iterative delta or system error for each type of node. RLXTBS and
RLXTBT contain the relaxation parameters that are input through the QINDAT File. The first index is
the node type, advection, radiation, etc. and the second index is the type of parameter: maximum value,
damping factor, and multiplying factor. RELAXV is the relaxation parameter used by the specified node,
EFACTB is the system error multiplier which is the measure of how quick the node is converging.
RELAXM is the relaxation multiplier that is applied at each node. This is how under relaxation is applied.
RERROR is the iterative delta associated with each node. The last three values are retained in the array
with the first index representing the oldest value. RLXGRP is a summary of the maximum values
encountered for each node group. This information is saved for print purposes.
The internal node ID contained in array TCPLND is lumped into internal node ID defined at the same
position in array TCPLCN. Although the internal energy balanced is performed as though the TCPLND
node is the same as the TCPLCN node, its individuality is retained and is updated after each converged
Main Index
566 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QTRAN Arrays
iteration. NTCPL is the total number of temperature coupling and is defined in common block IB106.
The arrays are originally sized with variable J52 which is defined in the DIMS Common Block.
Main Index
Chapter 12: Support Scripts and Codes
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
J Purpose 568
J QINDAT File Listing 569
Main Index
568 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Purpose
Purpose
Patran Thermal is a preference selection in Patran for creating a model to be solved by P/THERMAL,
the Patran thermal analysis module. The thermal model can be created and submitted directly from
Patran. Analysis results can then be read into the Patran database or postprocessing with the various
Patran tools, or for sharing the results with other Patran applications.
When the Patran Thermal preference is set, forms specific to input data required by the P/THERMAL
module will appear under Loads/BCs, Element Properties, Materials and Analysis. The User Preference
consists of the following:
• Element properties forms for defining properties of the elements in the model such as material.
• Loads/BCs forms for defining Temperature, Convection, Heat Flux, Volumetric Heat, View
factors, Pressure (hydraulic) and Mass Flow boundary conditions.
• Analysis form for defining solution type, parameters and job control.
• Materials form for defining material properties or material templates.
If Full Run is set, the Apply selection in the Analysis form will create the appropriate interface files and
execute the solver. The interface files created include:
• A neutral file
• The analysis control files qin.dat and vf.ctl
• The script for executing the model patq.inp
• Materials data file Mat.dat
Patran Thermal is designed to support the functionality in P/THERMAL 2.6A, including the View factor
code, the new coupled thermal/hydraulic networks and creation of a SINDA input deck. Overall, users
will find Patran Thermal a much easier to use product, without sacrificing the powerful capabilities of
P/THERMAL.
Main Index
Chapter 12: Support Scripts and Codes 569
QINDAT File Listing
Main Index
570 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
*
* Example title data before the $INSERT title.dat command which includes
* the title data from a translated PATRAN neutral file.
*
* NOTE: $INSERT records are used throughout the QIN.DAT file to load
* blocks of specific types of information at the appropriate
* position. If the data or file is not available, the insert
* record will have no effect. But, it will serve as a place
* holder for future runs.
*
*----------------------------------------------------------------------------
*
$ ; Terminate title data with a "$".
*
*****************************************************************************
*
* Section 5.2.2: Input Data File Echo Option
*
IECHO Y ; Data Echo? (Y=yes,N=no)
*
* ***************************************************************************
*
* Section 5.2.3: Temperature Scale Definition
*
$ECHO_ON
*
ISCALE K ; Output temperatures in Kelvin.
ICCALC K ; Calculate using Kelvin.
* Temperature options are R, F, K,
* and C.
TLABEL SECONDS ; Time units label is "SECONDS".
* This is label only, no time units
* conversion takes place.
*
* ***************************************************************************
*
* Section 5.2.4: Transient/Steady State Run Option Selection
*
* Options for the hydraulic solution
*
* HIOPT HSOL NTBHUP
* ----- ---- ------
HIOPT 0 2 200000 ; HIOPT = 0 = No hydraulic network
* 1 = Hydraulic network only
* 2 = Hydraulic network coupled
* to thermal network
* HSOL = 2 = Direct solver
* NTBHUP = Number of thermal iterations
* between hydraulic solutions
* for steady state or the
* number of time steps before
* hydraulic update for
* transient calculations.
*
* Options for the thermal solution
*
* IOPT SOL NITBUP MFLIPF
* ---- --- ------ ------
IOPT 1 0 4 8 ; IOPT = 3 = Steady State
* Other IOPT options are:
* 0 = data check only
* 1 = transient
* 2 = SS + Transient
* 3 = Steady State (SS)
* 4 = Transient + SS
* 5 = SS + Transient + SS
* SOL = 0 = STANDARD SOLUTION
* = 1 = WEAKLY NONLINEAR
Main Index
Chapter 12: Support Scripts and Codes 571
QINDAT File Listing
* SOLUTION.
* = 2 = Direct solution
* NITBUP = Number of ITerations
* Between conductive
* resistor UPdates if
* SOL = 1. If SOL = 0,
* NITBUP is how frequently
* all nodes are updated. If
* SOL=2, its the number of
* iterative solutions
* performed before before
* another direct calculation
* MFLIPF = Number of flip flops in
* the convergence value
* before a full bisection
* solution is used.
*
* ***************************************************************************
*
* Section 5.2.5: Iteration Limit Parameters
*
IMAX 36 ; Maximum Iterations per time step.
IMIN 9 ; Minimum Iterations per time step.
* IMAX should always be greater than IMIN by
* a factor of more than 2. If it is
* desireable to follow a transient very
* close, use value of IMAX = 30, IMIN = 8.
* If one doesn't care how close the
* transient is followed, then values such as
* IMAX = 250, IMIN = 20 could be used.
*
IMAXSS 2000 2000 ; Maximum number of Steady State Iterations
* for the thermal and hydraulic solutions
* respectively.
ISSDMP 2000 ; Number of Steady State Iterations per
* output dump.
* ***************************************************************************
*
* Section 5.2.6: Control Parameters
*
DT 1.000000E-4 1.000000E-30 ; Initial and minimum
* allowed time step.
*
TSTART 0.0000000000D-01 ; Start time.
TSTOP 40.0000000000D+00 ; Stop time.
*
TSFMIN 6.5000000000D-01 ; Shrinking time step factor.
TSFMAX 2.0000000000D+00 ; Expanding time step factor.
*
HYEPIS 1.0000000000D-04 ; Hydraulic convergence criteria
*
EPSISS 1.0000000000D-03 ; Steady State Convergence Criteria
* (in degrees ICCALC).
*
* EPSIT EPSIT2
* ---------------- ------
EPSIT 1.0000000000D-04 1.0D-07 ; EPSIT is the convergence criteria
* (in degrees ICCALC). EPSIT2 is
* the iterative delta cutout
* criteria in degrees ICCALC. For
* transient runs, any node whose
* iterative delta is less than EPSIT2
* will be removed from the iterative
* process, thus conserving CPU time.
* EPSIT2 should be several orders of
* magnitude less than EPSIT. If
* EPSIT2 is entered as blank or 0.0,
* all nodes are iterated until the
Main Index
572 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 573
QINDAT File Listing
Main Index
574 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 575
QINDAT File Listing
Main Index
576 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
*
$ ; Terminate the DEFNOD data with a "$".
*
*----------------------------------------------------------------------------
*
$INSERT tcoupl.dat
* Insert the TCOUPL.DAT file. This
* file contains the node IDs which are
* to be included in the analysis as if
* they were part of the companion node.
* Node location and identity are preserved.
*
*------------------------------------------------------------------------------
*
$ ; Terminate with a "$"
*
*----------------------------------------------------------------------------
*
$INSERT nodxyz.dat
* Insert the NODXYZ.DAT file. This
* file contains the node locations and
* the values are stored according to
* their definition of the nodes in the
* previous section.
*
*------------------------------------------------------------------------------
*
$ ; Terminate with a "$"
*
*
* ***************************************************************************
*
* Section 5.2.10 Data: Print Controls
*
* Section 5.2.10.1: Initial Output Print Interval
*
TPRINT 1.0 ; Initial Transient Print Interval.
*
* ---------------------------------------------------------------------------
*
* Section 5.2.10.2: Output Print Interval Adjustments
*
* New TPRINT Time
* ---------- ----
*PRINTA 0.2 1.1 ; Sets the print interval size
* This statement forces an output
* at 1.1 eventhough the print
* increment is 1.0. The print
* interval is changed to 0.2 and
* resulting print times would be
* 1.1, 1.3, 1.5, 1.7, etc.
*PRINTA -0.5 2.3 ; Sets the print interval size
* The negative sign on this
* statement would force
* print at 2.3 and on multiples
* of 0.5 there after. For example
* 2.3, 2.5, 3.0, etc.
*PRINTA 1.0 5.0 ; Sets the print interval size
*PRINTA 10.0 10.0 ; Sets the print interval size
*PRINTA 50.0 50.0 ; Sets the print interval size
* At time 50 the print interval
* will be changed to 50.
*
*
*
$ ; Terminate PRINTA data with a "$".
*
* ---------------------------------------------------------------------------
Main Index
Chapter 12: Support Scripts and Codes 577
QINDAT File Listing
*
* Section 5.2.10.3: Nodal Print Block Definitions
*
* NOTE: If no PBLOCK data is specified, the default is
* to print out all nodal data. With "PBLOCK 1 1 1" specified as below,
* printout of all but node 1 into the QOUT.DAT will be suppressed.
* All node data will still be printed out into the nodal results files
* generated by QTRAN.
*
*PBLOCK 1 1 1
*
* ---------------------------------------------------------------------------
*
* Section 5.2.10.4: Nodal Plot Block Definitions
*
* NOTE: If no IPLTBK data is specified, the plot file is not opened.
* With "IPLTBK 1 3 1" specified only those nodes between 1 and 3
* will be output to the plot file after each converged calculation.
* Also, only temperature in ICCALC units are output to the file.
*
*IPLTBK 1 3 1
*
$ ; The print and plot block is terminated with a "$".
*
*############################################################################
*
* Section 5.3: MATERIAL PROPERTY SECTION
*
$INSERT mat.dat
* Insert the material properties
* data file MAT.DAT.
*
$ ; End the material property data Section 5.3 with a "$".
*
*############################################################################
*
* Section 5.4.0: RESISTOR AND CAPACITOR DATA SET DEFINITIONS
*
* Section 5.4.1: Resistor Data Sets
*
*----------------------------------------------------------------------------
*
* This portion of the QIN.DAT file has a number of optional "$STATUS message"
* commands. These can be of some help in the event that QTRAN encounters an
* error and for some reason you have difficulty in ascertaining where the
* error occurred.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read conduc.dat
*
$INSERT conduc.dat,C ; the ",C" implies a binary file.
*
$STATUS conduc.dat input finished.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read fres.dat
*
$INSERT fres.dat ; hydraulic data
*
$STATUS fres.dat input finished.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read convec.dat
*
$INSERT convec.dat
Main Index
578 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 579
QINDAT File Listing
Main Index
580 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
*
* Section 5.5.5 Data: Pressure Hydraulic Control Macrofunctions
*
$STATUS Read in the pmacro.dat file.
*
$INSERT pmacro.dat
$INSERT pmacro_dir.dat
*
$STATUS pmacro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the PMACROfunction data with a "$".
*
$STATUS All MMACROfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.6 Data: Initially Fixed Nodes
*
$STATUS Read in the tfix.dat file.
*
$INSERT tfix.dat
*
$STATUS tfix.dat input complete.
*
*----------------------------------------------------------------------------
*
* Section 5.5.6 Data: Initially Fixed Pressure Nodes
*
$STATUS Read in the pfix.dat file.
*
$INSERT pfix.dat
*
$STATUS pfix.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the fixed node data with a "$".
*
$STATUS Fixed node data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.7 Data: Nodal Classification Changes
*
* [ None used for this problem. ]
*
$ ; Terminate CLASSification changes with a "$".
*
* ***************************************************************************
*
* Section 5.5.8 Data: Initial Global Temperature and Heat Source
*
TINITL 20.0 C ; Globally assign an initial
* temperature of 20.0 C
*
PINITL 101325.0 ; Globally assign an initial
* pressure of 101325 nt/m2
*
MGLOBL 0.0 ; Globally assign an initial
* mass flow rate 0.0 kg/sec
*
* MPIDGH MPIDGX MPIDGY MPIDGZ
* ------ ------ ------ ------
MPIDGH 0 0 0 0
*
* ; Material property IDs which define
Main Index
Chapter 12: Support Scripts and Codes 581
QINDAT File Listing
Main Index
582 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
*
* ***************************************************************************
*
* User input may follow
*
* ***************************************************************************
Main Index
Chapter 12: Support Scripts and Codes 583
QINDAT File Listing
Main Index
584 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 585
QINDAT File Listing
Main Index
586 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 587
QINDAT File Listing
*
* This portion of the QIN.DAT file has a number of optional "$STATUS message"
* commands. These can be of some help in the event that QTRAN encounters an
* error and for some reason you have difficulty in ascertaining where the
* error occurred.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read conduc.dat
*
$INSERT conduc.dat,C ; the ",C" implies a binary file.
*
$STATUS conduc.dat input finished.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read fres.dat
*
$INSERT fres.dat ; hydraulic data
*
$STATUS fres.dat input finished.
*
*----------------------------------------------------------------------------
*
$STATUS Beginning to read convec.dat
*
$INSERT convec.dat
$INSERT gap_convec.dat ; Gap convection between regions
$INSERT ../convec.dat.apnd ; Supplemental resistors defined by the user
*
$STATUS convec.dat input finished.
*
*----------------------------------------------------------------------------
*
* These commands are used to $INSERT the radiation resistor data generated
* by P/VIEWFACTOR.
*
$STATUS Beginning to read vfres.dat.
*
$INSERT vfres.dat,RAD ; the ",RAD" inplies a binary file.
$INSERT trarst.dat ; Radiation resistors defined by TRASYS
$INSERT nevrst.dat ; Radiation resistors defined by NEVADA
$INSERT gap_rad.dat ; Gap radiation between two nodes.
*
$STATUS vfres.dat input finished.
*
*----------------------------------------------------------------------------
*
STATUS Beginning to read res.dat.
*
$INSERT res.dat
*
$STATUS res.dat input finished.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the resistor input with a "$".
*
$STATUS All resistor data input is complete.
*
* ***************************************************************************
*
* Section 5.4.2: Capacitor Data Sets
*
$STATUS Beginning to read cap.dat.
*
$INSERT cap.dat,CAP ; the ",CAP" implies a binary file.
$INSERT ../cap.dat.apnd ; Supplemental capacitors defined by the user
Main Index
588 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
*
$STATUS cap.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the capacitor data input with a "$".
*
$STATUS All thermal network data has now been successfully input.
*
*############################################################################
*
* Section 5.5.1: Microfunction Definitions
*
$STATUS Read in the micro.dat file.
*
$INSERT micro.dat
$INSERT tramic.dat ; Time dependent heating defined by TRASYS
$INSERT nevmic.dat ; Time dependent heating defined by NEVADA
*
$STATUS micro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the microfunction data input with a "$".
*
$STATUS All microfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.2: Heat Source/Sink Macrofunction Definitions
*
$STATUS Read in the qmacro.dat file.
*
$INSERT qmacro.dat
$INSERT traqma.dat ; Variable heat load defined by TRASYS
$INSERT nevqma.dat ; Variable heat load defined by NEVADA
*
$STATUS qmacro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the QMACROfunction data with a "$".
*
$STATUS All QMACROfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.3 Data: Temperature Control Macrofunctions
*
$STATUS Read in the tmacro.dat file.
*
$INSERT tmacro.dat
*
$STATUS tmacro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the TMACROfunction data with a "$".
*
$STATUS All TMACROfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.4 Data: Mass Flow Hydraulic Control Macrofunctions
*
$STATUS Read in the mmacro.dat file.
*
$INSERT mmacro.dat
Main Index
Chapter 12: Support Scripts and Codes 589
QINDAT File Listing
*
$STATUS mmacro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the MMACROfunction data with a "$".
*
$STATUS All MMACROfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.5 Data: Pressure Hydraulic Control Macrofunctions
*
$STATUS Read in the pmacro.dat file.
*
$INSERT pmacro.dat
*
$STATUS pmacro.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the PMACROfunction data with a "$".
*
$STATUS All MMACROfunction data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.6 Data: Initially Fixed Nodes
*
$STATUS Read in the tfix.dat file.
*
$INSERT tfix.dat
*
$STATUS tfix.dat input complete.
*
*----------------------------------------------------------------------------
*
* Section 5.5.6 Data: Initially Fixed Pressure Nodes
*
$STATUS Read in the pfix.dat file.
*
$INSERT pfix.dat
*
$STATUS pfix.dat input complete.
*
*----------------------------------------------------------------------------
*
$ ; Terminate the fixed node data with a "$".
*
$STATUS Fixed node data has now been successfully input.
*
* ***************************************************************************
*
* Section 5.5.7 Data: Nodal Classification Changes
*
* [ None used for this problem. ]
*
$ ; Terminate CLASSification changes with a "$".
*
* ***************************************************************************
*
* Section 5.5.8 Data: Initial Global Temperature and Heat Source
*
TINITL 20.0 C ; Globally assign an initial
* temperature of 20.0 C
*
PINITL 101325.0 ; Globally assign an initial
Main Index
590 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QINDAT File Listing
Main Index
Chapter 12: Support Scripts and Codes 591
QINDAT File Listing
*----------------------------------------------------------------------------
*
$ ; Terminate the constant heat source and mass flow rate data with a "$".
*
* ***************************************************************************
*
* END OF QIN DATA FILE
*
* ***************************************************************************
Main Index
592 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QSTAT - QTRAN STATUS
qstat b
The number of iteration can become large and if you are monitoring a job and would like to see the being
and ending iterations the B option will limit the output and still the information output and limit it to about
25 lines. The information in the file includes the iteration number, the node ID of the node that had the
largest iterative delta temperature, the maximum iterative delta times its relaxation value, the node
temperature and the new relaxation value for the node in question. The iterative delta time the relaxation
value is the temperature change that will be applied to the node for the next iteration cycle. The QTRAN
cpu time stamp is also included
Main Index
Chapter 12: Support Scripts and Codes 593
QSTAT - QTRAN STATUS
qstat t
Rather than seeing some of the iterations at the being and end of the STATBIN file, the “t” option
supplies a limited output for the latest iterations.
qstat c 15
If you wish to closely monitor a job, the qstat c option will provide the same output as the “t” option but
will give a status report approximately every 1.5 minutes. It will repeat the process 10 times or until the
job has finished. If you wish to get more than 10 outputs a second parameter can be specified that defines
how many outputs are desired.
qstat s
For transient run you get the same report with the qstat or qstat with the “s” option; however, it only
applies to the latest time step as shown below. The status file number is an indication as to how many
time steps have been executed to this point. The time listed is the old time. The time variable is not
advanced until a converged solution has been obtained thus the actual time represented in the following
example is 10 seconds.
Main Index
594 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QSTAT - QTRAN STATUS
qstat l
At times it many be desirable to see more than one time point to observe the progression of the time step.
The “l” option provides this capability. The STATBIN file will not be reset after each converged solution
but will continue to put the convergence status in the file until it is turned off with a qstat s command at
which time the STATBIN will revert to the default of a single time step per file. An example of multiple
output is shown below.
Main Index
Chapter 12: Support Scripts and Codes 595
QSTAT - QTRAN STATUS
qstat g
On long running jobs it could be desirable to do more than monitor the progression of the execution. The
“g”, “p” and “r” option give the user the ability to interface with the job during execution and allows them
to change several of the solution controls. The “g” option will interrupt a job and print a file with these
alterable parameters to a file at that time. The execution will continue as soon as it has finished writing
the old parameter file. The qstat g command can be issued prior to executing QTRAN if for example it
was desired to get the parameters from a restart job.
qstat p
The qstat p allows one to edit an old parameters file or create a new one from default values. Execution
of this command enables the user to get a help file with a summary of what can be accomplished with the
dynamic series of qstat option.
Main Index
596 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QSTAT - QTRAN STATUS
The parameters that can be altered with the “p” option are listed below. While manipulation the
parameters with this option the QTRAN problem will continue to run.
Main Index
Chapter 12: Support Scripts and Codes 597
QSTAT - QTRAN STATUS
qstat r
The command qstat r is a combination of qstat g followed by qstat p. However, in this case the the
QTRAN run will be interrupted for as much as 15 minutes wall clock time while you make the changes.
After that time the QTRAN run will resume and you can continue modifying the parameters file and
submit it later as the same as if you had issued the qstat p command.
Main Index
598 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
QSTAT - QTRAN STATUS
Main Index
Appendix A: References
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
A References
J References 600
Main Index
600 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
References
References
1. Hughes, Thomas J. R. “Unconditionally Stable Algorithms for Nonlinear Heat Conduction,”
Computer Methods in Applied Mechanics and Engineering, Vol 10, pp. 135-139, North-Holland
Publishing Company, 1977.
2. Forsythe, G. E. and Wasow, W. R. Finite Difference Methods for Partial Differential Equations,
pp. 119-121, John Wiley & Sons, New York, 1960.
3. James, M. L., Smith, G. M., and Wolford, J. C. Applied Numerical Methods for Digital
Computation with FORTRAN and CSMP, 2nd ed., pp. 111-113, IEP - A Dun-Donnelley
Publisher, New York, 1977.
4. White, F. M. Viscous Fluid Flow, McGraw-Hill, 1974.
5. Siegel, R., and Howell, J. R. Thermal Radiation Heat Transfer, 2nd ed., McGraw-Hill, 1981.
6. Karlekar, B. V., and Desmond, R. M. Engineering Heat Transfer, West Publishing Co, 1977.
7. Gebhart, B. Heat Transfer, 2nd ed., McGraw-Hill, 1971.
8. Bird, R. B., Stewart, W. E., and Lightfoot, E. N. Transport Phenomena, John Wiley & Sons, 1960.
9. Hageman, L. A., and Young, D. M. Applied Iterative Methods, Academic Press, New York, 1981.
10. Ames, W. F. Numerical Methods for Partial Differential Equations, 2nd ed., Academic Press,
New York, 1977.
11. Champman, A. J. Heat Transfer, 4th ed,.MacMillan Publishing Company, 1984.
12. Kraus, A. D., and Bar-Cohen, A. Thermal Analysis and Control of Electronic Equipment, pp. 210-
211, Hemisphere Publishing Corp., 1983.
13. Shlyhov, Y.L.. "Calculating Thermal Contact Resistance of Machined Metal Surfaces,"
Teploenergetika, Vol 12, No. 10, pp 79-83, 1965.
14. Kreith, Frank, and Bohn, Mark S., Principles of Heat Transfer, 5th ed., PWS Publishing
Company, 1997.
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
J
Materials References, Classification, Quality Code and Index 602
Main Index
602 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 603
Materials References, Classification, Quality Code and Index
; Material: ANTIMONY
; References: 20,1,32,42,27
MID 3 301 301 301 304 305 306
;
; Material: ANTIMONY (LIQUID)
; References: 1,47,42,27,20,14
MID 4 401 401 401 404 405 406
;
; Material: ARSENIC, GREY
; References: 1,27,41,42
MID 5 501 501 501 504 505 506
;
; Material: BERYLLIUM
; References: 20,6,1,32,34,27,36,42
MID 6 601 601 601 604 605 606
;
; Material: BISMUTH
; References: 2,1,27,43,41,42,47
MID 7 701 701 701 704 705 706
;
; Material: BISMUTH (LIQUID)
; References: 1,14,27,43,47
MID 8 801
801 801 804 805 806
;
; Material: CADMIUM
; References: 2,1,32,42,43,27,41,47
MID 9 901 901 901 904 905 906
;
; Material: CADMIUM (LIQUID)
; References: 2,1,32,42,43,27,41,47
MID 10 1001 1001 1001 1004 1005 1006
;
; Material: COBALT
; References: 20,27,1,32,43,30,41,42
MID 11 1101 1101 1101 1104 1105 1106
;
; Material: COPPER
; References: 20,1,27,32,34,37,42,47
MID 12 1201 1201 1201 1204 1205 1206
;
; Material: GOLD
; References: 20,6,1,32,27,42,41,2
MID 13 1301 1301 1301 1304 1305 1306
;
; Material: GOLD (LIQUID)
; References: 14,20,27,42,43
MID 14 1401 1401 1401 1404 1405 1406
;
; Material: CARBON, DIAMOND GEM QUALITY TYPE 1
; References: 1,20,27
MID 15 1501 1501 1501 1504 1505 0
;
; Material: CARBON, GRAPHITE (TYPICAL K)
; References: 1,2,20,27,32,42,51
MID 16 1601 1601 1601 1604 1605 1606
;
; Material: CARBON, AMORPHOUS (CARBON STOCK)
; References: 27,1
MID 17 1701 1701 1701 1704 1705 1706
;
; Material: IRON (-51 TO 1537 DEG C)
; References: 20,1,32,27,42,44,51
MID 18 1801 1801 1801 1804 1805 0
;
; Material: IRON (-273 TO 763 DEG C)
; References: 20,1,32,27,42,44,51
MID 19 1901 1901 1901 1904 1905 0
Main Index
604 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: IRON (0 TO 3000 DEG C)
; References: 20,1,32,27,42,44,51
MID 20 2001 2001 2001 2004 2005 2006
;
; Material: LEAD
; References: 2,1,32,27,37,42
MID 21 2101 2101 2101 2104 2105 2106
;
; Material: LEAD (LIQUID)
; References: 1,2,14,27,37,42,43,47
MID 22 2201 2201 2201 2204 2205 2206
;
; Material: MAGNESIUM
; References: 20,1,32,27,42
MID 23 2301 2301 2301 2304 2305 2306
;
; Material: MAGNESIUM (LIQUID)
; References: 1,14,20,27,32,43
MID 24 2401 2401 2401 2404 2405 2406
;
; Material: MANGANESE
; References: 20,1,32,27,43,42
MID 25 2501 2501 2501 2504 2505 0
;
; Material: MOLYBDENUM
; References: 20,6,1,32,41,43,42,47,14
MID 26 2601 2601 2601 2604 2605 2606
;
; Material: NICKEL
; References: 20,2,1,32,37,41,42,51
MID 27 2701 2701 2701 2704 2705 2706
;
; Material: OSMIUM
; References: 27,20,42,41
MID 28 2801 2801 2801 2804 2805 2806
;
; Material: PLATINUM
; References: 20,1,32,27,41,43,42
MID 29 2901 2901 2901 2904 2905 2906
;
; Material: PLUTONIUM
; References: 20,31,3,27,43,42,41,36,44
MID 30 3001 3001 3001 3004 3005 3006
;
; Material: SILVER
; References: 20,6,1,27,2,32,42,47,14,43
MID 31 3101 3101 3101 3104 3105 3106
;
; Material: SILVER (LIQUID)
; References: 27,32,42,43
MID 32 3201 3201 3201 3204 3205 3206
;
; Material: TANTALUM
; References: 20,1,27,32,37,43
MID 33 3301 3301 3301 3304 3305 3306
;
; Material: TECHNICIUM
; References: 27,42
MID 34 3401 3401 3401 3404 3405 3406
;
; Material: THORIUM
; References: 20,32,34,27,37,43,44,41
MID 35 3501 3501 3501 3504 3505 3506
;
; Material: TIN
; References: 2,1,27,32,42,41,47
MID 36 3601 3601 3601 3604 3605 3606
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 605
Materials References, Classification, Quality Code and Index
;
; Material: TIN (LIQUID)
; References: 1,14,27,32,41,42,43
MID 37 3701 3701 3701 3704 3705 3706
;
; Material: TITANIUM
; References: 20,27,32,37,42,43,41,1
MID 38 3801 3801 3801 3804 3805 3806
;
; Material: TUNGSTEN
; References: 20,1,32,34,27,37,42,41,43
MID 39 3901 3901 3901 3904 3905 3906
;
; Material: URANIUM
; References: 20,31,32,36,27,37,42,41,43,44,34
MID 40 4001 4001 4001 4004 4005 4006
;
; Material: ZINC
; References: 2,1,32,27,42,20,41,47,51
MID 41 4101 4101 4101 4104 4105 4106
;
; Material: ZINC (LIQUID)
; References: 14,20,27,32,43,47
MID 42 4201 4201 4201 4204 4205 4206
;
; Material: ZIRCONIUM
; References: 20,27,32,37,43,42,41
MID 43 4301 4301 4301 4304 4305 4306
;
; Material: CHROMIUM
; References: 20,1,27,32,43,42
MID 44 4401 4401 4401 4404 4405 4406
;
; Material: MERCURY (LIQUID)
; References: 1,27,28,42,43,47,14
MID 45 4501 4501 4501 4504 4505 4506
;
; Material: INDIUM
; References: 1,27,43,30,42,41
MID 46 4601 4601 4601 4604 4605 4606
;
; Material: INDIUM (LIQUID)
; References: 1,42,43,47
MID 47 4701 4701 4701 4704 4705 4706
;
; Material: LITHIUM
; References: 1,27,28,41,43,42,47
MID 48 4801 4801 4801 4804 4805 4806
;
; Material: LITHIUM (LIQUID)
; References: 1,27,28,41,42,43,47
MID 49 4901 4901 4901 4904 4905 4906
;
; Material: SODIUM
; References: 2,1,27,28,41,42,43,51
MID 50 5001 5001 5001 5004 5005 5006
;
; Material: SODIUM (LIQUID)
; References: 1,14,27,28,42,43,47,51
MID 51 5101 5101 5101 5104 5105 5106
;
; Material: POTASSIUM
; References: 1,27,28,42,41,43,51
MID 52 5201 5201 5201 5204 5205 5206
;
; Material: POTASSIUM (LIQUID)
; References: 14,27,28,43,47,51
MID 53 5301 5301 5301 5304 5305 5306
Main Index
606 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: CESIUM
; References: 1,14,27,28,32,43,47
MID 54 5401 5401 5401 5404 5405 5406
;
; Material: CESIUM (LIQUID)
; References: 14,27,28,32,43,47
MID 55 5501 5501 5501 5504 5505 5506
;
; Material: PALLADIUM
; References: 20,41,42,27,43
MID 56 5601 5601 5601 5604 5605 5606
;
; Material: BARIUM
; References: 20,27,29,42,43
MID 57 5701 5701 5701 5704 5705 5706
;
; Material: NIOBIUM
; References: 20,27,32,43,44,42
MID 58 5801 5801 5801 5804 5805 5806
;
; Material: RHENIUM
; References: 27,43,41,42
MID 59 5901 5901 5901 5904 5905 5906
;
; Material: SILICON
; References: 20,1,27,41,43,42,48
MID 60 6001 6001 6001 6004 6005 6006
;
; Material: GERMANIUM (INTRINSIC, P-TYPE)
; References: 20,27,42,43,1,48
MID 61 6101 6101 6101 6104 6105 6106
;
; Material: GERMANIUM (N-TYPE)
; References: 20,27,42,43,1,48
MID 62 6201 6201 6201 6204 6205 6206
;
; Material: BORON
; References: 20,27,30,42,43,48
MID 63 6301 6301 6301 6304 6305 6306
;
; Material: HAFNIUM
; References: 20,32,27,42,43,41
MID 64 6401 6401 6401 6404 6405 6406
;
; Material: IRIDIUM
; References: 27,41,20,42,43
MID 65 6501 6501 6501 6504 6505 6506
;
; Material: RHODIUM
; References: 20,27,43,42,41
MID 66 6601 6601 6601 6604 6605 6606
;
; Material: VANADIUM
; References: 20,32,27,41,42,43
MID 67 6701 6701 6701 6704 6705 6706
;
; Material: RUBIDIUM
; References: 1,27,28,42,43,47
MID 68 6801 6801 6801 6804 6805 6806
;
; Material: RUBIDIUM (LIQUID)
; References: 1,14,27,28,43,47
MID 69 6901 6901 6901 6904 6905 6906
;
; Material: STRONTIUM
; References: 20,28,42,27
MID 70 7001 7001 7001 7004 7005 7006
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 607
Materials References, Classification, Quality Code and Index
;
; Material: RUTHENIUM
; References: 20,42,1,27
MID 71 7101 7101 7101 7104 7105 7106
;
; Material: CALCIUM
; References: 27,1,42,43,41
MID 72 7201 7201 7201 7204 7205 7206
;
; Material: GALLIUM
; References: 27,42,43,1
MID 73 7301 7301 7301 7304 7305 7306
;
; Material: GALLIUM (LIQUID)
; References: 1,14,27,43,47
MID 74 7401 7401 7401 7404 7405 7406
;
; Material: IODINE (SOLID)
; References: 27,42,41,1
MID 75 7501 7501 7501 7504 7505 7506
;
; Material: PHOSPHORUS (WHITE)
; References: 27
MID 76 7601 7601 7601 7604 7605 7606
;
; Material: SELENIUM (GREY)
; References: 27,43,42,1
MID 77 7701 7701 7701 7704 7705 7706
;
; Material: SULFUR
; References: 27,1,42,30,2,41
MID 78 7801 7801 7801 7804 7805 7806
;
; Material: THALLIUM
; References: 41,27,1,42,47
MID 79 7901 7901 7901 7904 7905 7906
;
; Material: THALLIUM (LIQUID)
; References: 1,14,27,42,43,47
MID 80 8001 8001 8001 8004 8005 8006
;
; Material: SCANDIUM
; References: 20,27,41,43
MID 81 8101 8101 8101 8104 8105 8106
;
; Material: YTTRIUM
; References: 41,27,1,20,42,43
MID 82 8201 8201 8201 8204 8205 8206
;
; Material: LANTHANUM
; References: 41,27,1,20,42
MID 83 8301 8301 8301 8304 8305 0
;
; Material: CERIUM
; References: 41,27,20,42
MID 84 8401 8401 8401 8404 8405 8406
;
; Material: PRASEODYMIUM
; References: 41,27,20,42
MID 85 8501 8501 8501 8504 8505 8506
;
; Material: NEODYMIUM
; References: 41,20,42
MID 86 8601 8601 8601 8604 8605 8606
;
; Material: SAMARIUM
; References: 20,27,41,42,43
MID 87 8701 8701 8701 8704 8705 8706
Main Index
608 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: EUROPIUM
; References: 20,27,41,43
MID 88 8801 8801 8801 8804 8805 8806
;
; Material: GADOLINIUM
; References: 41,27,20,42
MID 89 8901 8901 8901 8904 8905 8906
;
; Material: TERBIUM
; References: 20,27,41,42,43
MID 90 9001 9001 9001 9004 9005 9006
;
; Material: DYSPROSIUM
; References: 41,27,20,42
MID 91 9101 9101 9101 9104 9105 9106
;
; Material: HOLMIUM
; References: 20,27,41,42,43
MID 92 9201 9201 9201 9204 9205 9206
;
; Material: ERBIUM
; References: 41,27,20,42
MID 93 9301 9301 9301 9304 9305 9306
;
; Material: THULIUM
; References: 20,27,41,42,43
MID 94 9401 9401 9401 9404 9405 9406
;
; Material: YTTERBIUM
; References: 20,27,41,42,43
MID 95 9501 9501 9501 9504 9505 9506
;
; Material: LUTETIUM
; References: 20,27,41
MID 96 9601 9601 9601 9604 9605 9606
;
; Material: PROMETHIUM
; References: 20,27,42
MID 97 9701 9701 9701 9704 9705 9706
;
; Material: ACTINIUM
; References: 20,27,42
MID 98 9801 9801 9801 9804 9805 9806
;
; Material: AMERICIUM
; References: 20,27
MID 99 9901 9901 9901 9904 9905 0
;
; Material: ASTITINE
; References: 42
MID 100 10001 10001 10001 10004 10005 10006
;
; Material: BERKELIUM
; References: 27
MID 101 10101 10101 10101 10104 10105 0
;
; Material: CALIFORNIUM
; References:
MID 102 10201 10201 10201 10204 10205 0
;
; Material: CURIUM
; References: 20,27
MID 103 10301 10301 10301 10304 10305 0
;
; Material: EINSTEINIUM
; References:
MID 104 10401 10401 10401 10404 10405 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 609
Materials References, Classification, Quality Code and Index
;
; Material: FERMIUM
; References:
MID 105 10501 10501 10501 10504 10505 0
;
; Material: FRANCIUM
; References: 42
MID 106 10601 10601 10601 10604 10605 10606
;
; Material: MENDELEVIUM
; References:
MID 107 10701 10701 10701 10704 10705 0
;
; Material: NEPTUNIUM
; References: 20,27
MID 108 10801 10801 10801 10804 10805 0
;
; Material: NOBELIUM
; References:
MID 109 10901 10901 10901 10904 10905 0
;
; Material: POLONIUM
; References: 20,27
MID 110 11001 11001 11001 11004 11005 11006
;
; Material: PROTACTINIUM
; References: 20,27
MID 111 11101 11101 11101 11104 11105 11106
;
; Material: RADIUM
; References: 27
MID 112 11201 11201 11201 11204 11205 11206
;
; Material: TELLURIUM
; References: 27,20,42,41,1
MID 113 11301 11301 11301 11304 11305 11306
;
; Material: LAWRENCIUM
; References:
MID 114 11401 11401 11401 11404 11405 0
;
; Material: ARGON (GAS)
; References: 27,2,42,41
MID 115 11501 11501 11501 11504 11505 0
;
; Material: CHLORINE (GAS)
; References: 27,1,42,2
MID 116 11601 11601 11601 11604 11605 0
;
; Material: FLUORINE (GAS)
; References: 27,42
MID 117 11701 11701 11701 11704 11705 0
;
; Material: HELIUM (GAS)
; References: 27,1,2,42
MID 118 11801 11801 11801 11804 11805 0
;
; Material: HYDROGEN (GAS)
; References: 27,2,42,1
MID 119 11901 11901 11901 11904 11905 0
;
; Material: NEON (GAS)
; References: 27,2,1,42
MID 120 12001 12001 12001 12004 12005 0
;
; Material: NITROGEN (GAS)
; References: 27,2,42,1
MID 121 12101 12101 12101 12104 12105 0
Main Index
610 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: OXYGEN (GAS)
; References: 27,42,1,2
MID 122 12201 12201 12201 12204 12205 0
;
; Material: XENON
; References: 27,42
MID 123 12301 12301 12301 12304 12305 12306
;
; Material: BROMINE (GAS)
; References: 27,1,42
MID 124 12401 12401 12401 12404 12405 0
;
; Material: DEUTERIUM
; References: 27
MID 125 12501 12501 12501 12504 12505 0
;
; Material: KRYPTON (GAS)
; References: 27,1,42
MID 126 12601 12601 12601 12604 12605 12606
;
; Material: RADON GAS
; References: 27
MID 127 12701 12701 12701 12704 12705 0
;
; Material: TRITIUM GAS
; References:
MID 128 12801 12801 12801 12804 12805 0
;
; Material: ALUMINUM ALLOY 7075-T6 (AS RECEIVED)
; References: 20,41
MID 129 12901 12901 12901 12904 12905 12906
;
; Material: ALUMINUM ALLOY 7075-T6 (ANNEALED)
; References: 20,41
MID 130 13001 13001 13001 13004 13005 13006
;
; Material: ALUMINUM ALLOYS (AL, MG 2.5-5.0)
; References: 1,41
MID 131 13101 13101 13101 13104 13105 13106
;
; Material: ALUMINUM ALLOY 7079
; References: 37,41
MID 132 13201 13201 13201 13204 13205 13206
;
; Material: ALUMINUM ALLOYS 2024-T4 AND 24S-24 (AR)
; References: 20,41
MID 133 13301 13301 13301 13304 13305 13306
;
; Material: ALUMINUM ALLOY 2024-5-T4 (ANNEALED)
; References: 20,41
MID 134 13401 13401 13401 13404 13405 13406
;
; Material: ALUMINUM ALLOY (AL99.0, AVERAGE TRTMT)
; References: 1,6,14,20,37,41,471,6,14,20,37,41,47
MID 135 13501 13501 13501 13504 13505 13506
;
; Material: ALUMINUM ALLOY (AL96.0, WROT OR ANNLD)
; References: 1,6,14,20,37,41,47
MID 136 13601 13601 13601 13604 13605 13606
;
; Material: ALUMINUM ALLOY (AL92.0, WROT OR ANNLD)
; References: 1,6,14,20,37,41,47
MID 137 13701 13701 13701 13704 13705 13706
;
; Material: ALUMINUM ALLOY (AL84.0, WROT OR ANNLD)
; References: 1,6,14,20,37,41,47
MID 138 13801 13801 13801 13804 13805 13806
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 611
Materials References, Classification, Quality Code and Index
;
; Material: ALUMINUM ALLOY (AL84.0, AVERAGE TRTMT)
; References: 1,6,14,20,37,41,47
MID 139 13901 13901 13901 13904 13905 13906
;
; Material: ALUMINUM ALLOY (AL90.0, CAST OR TEMPD)
; References: 1,6,14,20,37,41,47
MID 140 14001 14001 14001 14004 14005 14006
;
; Material: ALUMINUM ALLOY (AL84.0, CAST OR TEMPD)
; References: 1,6,14,20,37,41,47
MID 141 14101 14101 14101 14104 14105 14106
;
; Material: BRASS, ALUMINUM (CU76, ZN22, AL2)
; References: 1
MID 142 14201 14201 14201 14204 14205 0
;
; Material: BRASS, CARTRIDGE (CU70, ZN30)
; References: 1,2,20,41,46
MID 143 14301 14301 14301 14304 14305 0
;
; Material: BRASS, LEADED
; References: 6,41
MID 144 14401 14401 14401 14404 14405 0
;
; Material: BRASS, MUNTZ METAL
; References: 1,41
MID 145 14501 14501 14501 14504 14505 0
;
; Material: BRASS, RED, CAST (CU85, ZN5, PB5, SN3)
; References: 1,41
MID 146 14601 14601 14601 14604 14605 0
;
; Material: BRASS, RED, WROUGHT (CU85, ZN15)
; References: 1,41
MID 147 14701 14701 14701 14704 14705 0
;
; Material: BRASS, TIN (NAVAL AND ADMIRALTY)
; References: 1,2,41
MID 148 14801 14801 14801 14804 14805 0
;
; Material: BRASS, YELLOW (CU65, ZN35)
; References: 1,6,41
MID 149 14901 14901 14901 14904 14905 0
;
; Material: BRONZE (CU75, SN25)
; References: 1,2
MID 150 15001 15001 15001 15004 15005 0
;
; Material: BRONZE, ALUMINUM (CU92, AL8)
; References: 1,6,41
MID 151 15101 15101 15101 15104 15105 0
;
; Material: BRONZE, ARCHITECTURAL
; References: 1,41
MID 152 15201 15201 15201 15204 15205 0
;
; Material: BRONZE, COMMERCIAL
; References: 1,2,38,41
MID 153 15301 15301 15301 15304 15305 0
;
; Material: BRONZE, MANGANESE
; References: 1,41
MID 154 15401 15401 15401 15404 15405 0
;
; Material: BRONZE, PHOSPHER 10 PERCENT
; References: 1,41
MID 155 15501 15501 15501 15504 15505 0
Main Index
612 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: BRONZE, PHOSPHER 5 PERCENT
; References: 6,41
MID 156 15601 15601 15601 15604 15605 0
;
; Material: BRONZE, PHOSPHER 1.25 PERCENT
; References: 6,41
MID 157 15701 15701 15701 15704 15705 0
;
; Material: BRONZE, SILICON, HIGH
; References: 1,6,41
MID 158 15801 15801 15801 15804 15805 0
;
; Material: BRONZE, SILICON, LOW
; References: 1,6,41
MID 159 15901 15901 15901 15904 15905 0
;
; Material: BRONZE, TIN (CAST), HIGH LEADED
; References: 6,41
MID 160 16001 16001 16001 16004 16005 0
;
; Material: BRONZE, TIN (CAST), LEADED
; References: 6
MID 161 16101 16101 16101 16104 16105 0
;
; Material: BERYLLIUM COPPER (CU BAL, BE 0.38-0.55)
; References: 1
MID 162 16201 16201 16201 16204 16205 16206
;
; Material: BERYLLIUM COPPER (CU BAL, BE1.7-1.9)
; References: 1,6,41
MID 163 16301 16301 16301 16304 16305 16306
;
; Material: CHROMIUM COPPER (CU BAL, CR0.5)
; References: 6,20,47
MID 164 16401 16401 16401 16404 16405 16406
;
; Material: COPPER ALLOY NICKEL SILVER (NI 10-20)
; References: 1,2,6,41,47
MID 165 16501 16501 16501 16504 16505 16506
;
; Material: COPPER GILDING METAL (CU95, ZN5)
; References: 1,41
MID 166 16601 16601 16601 16604 16605 0
;
; Material: COPPER, WROUGHT (ETP, DHP, TE0.5, PB1)
; References: 41
MID 167 16701 16701 16701 16704 16705 16706
;
; Material: COPPER ALLOY MANGANIN
; References: 2
MID 168 16801 16801 16801 16804 16805 0
;
; Material: COPPER ALLOY (CU99.4, AL0.3, ZR0.27)
; References: 20
MID 169 16901 16901 16901 16904 16905 16906
;
; Material: COPPER ALLOY (CU90, NI10)
; References: 1,6,41
MID 170 17001 17001 17001 17004 17005 0
;
; Material: COPPER ALLOY (CU70, NI30)
; References: 1,6,41
MID 171 17101 17101 17101 17104 17105 0
;
; Material: MAGNESIUM ALLOY AM100A (CASTING)
; References: 41
MID 172 17201 17201 17201 17204 17205 17206
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 613
Materials References, Classification, Quality Code and Index
;
; Material: MAGNESIUM ALLOY AZ31(X,S) (WROUGHT)
; References: 14,20,47
MID 173 17301 17301 17301 17304 17305 17306
;
; Material: MAGNESIUM ALLOY AZ31B(P,S) (WROUGHT)
; References: 1,20,41
MID 174 17401 17401 17401 17404 17405 17406
;
; Material: MAGNESIUM ALLOY AZ61A(X), AZM (WROUGHT)
; References: 14,41,47
MID 175 17501 17501 17501 17504 17505 17506
;
; Material: MAGNESIUM ALLOY AZ63A(AC,F) (CASTING)
; References: 14,41
MID 176 17601 17601 17601 17604 17605 17606
;
; Material: MAGNESIUM ALLOY AZ80A(X,FRGD) (WROUGHT)
; References: 1,20,37,41
MID 177 17701 17701 17701 17704 17705 17706
;
; Material: MAGNESIUM ALLOY AZ81A(T4) (CASTING)
; References: 41
MID 178 17801 17801 17801 17804 17805 17806
;
; Material: MAGNESIUM ALLOY AZ855(X) (WROUGHT)
; References: 47
MID 179 17901 17901 17901 17904 17905 17906
;
; Material: MAGNESIUM ALLOY AZ91A,B (DC) (CASTING)
; References: 1,14,41,47
MID 180 18001 18001 18001 18004 18005 18006
;
; Material: MAGNESIUM ALLOY AZ91C(AC) (CASTING)
; References: 1,41
MID 181 18101 18101 18101 18104 18105 18106
;
; Material: MAGNESIUM ALLOY AZ92A(AC) (CASTING)
; References: 1,14,41
MID 182 18201 18201 18201 18204 18205 18206
;
; Material: MAGNESIUM ALLOY A3A (WROUGHT)
; References: 41
MID 183 18301 18301 18301 18304 18305 18306
;
; Material: MAGNESIUM ALLOY A8(AC OR ST) (CASTING)
; References: 47
MID 184 18401 18401 18401 18404 18405 18406
;
; Material: MAGNESIUM ALLOY BZ33A(AC,AH) (CASTING)
; References: 1
MID 185 18501 18501 18501 18504 18505 18506
;
; Material: MAGNESIUM ALLOY EK30A, H812 (CASTING)
; References: 20,41
MID 186 18601 18601 18601 18604 18605 18606
;
; Material: MAGNESIUM ALLOY EK41A(T5,T6) (CASTING)
; References: 41
MID 187 18701 18701 18701 18704 18705 18706
;
; Material: MAGNESIUM ALLOY EK33A, H811 (CASTING)
; References: 20,41
MID 188 18801 18801 18801 18804 18805 18806
;
; Material: MAGNESIUM ALLOY HK31A(H24) (CASTING)
; References: 1,20,41
MID 189 18901 18901 18901 18904 18905 18906
Main Index
614 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: MAGNESIUM ALLOY HK31A(O) (CASTING)
; References: 1,20,41
MID 190 19001 19001 19001 19004 19005 19006
;
; Material: MAGNESIUM ALLOY HK31A(T6) (CASTING)
; References: 1,20,41
MID 191 19101 19101 19101 19104 19105 19106
;
; Material: MAGNESIUM ALLOY HM21A(O,H24) (WROUGHT)
; References: 41
MID 192 19201 19201 19201 19204 19205 19206
;
; Material: MAGNESIUM ALLOY HM31A (WROUGHT)
; References: 20,41
MID 193 19301 19301 19301 19304 19305 19306
;
; Material: MAGNESIUM ALLOY HZ32A(AC),ZT1 (CASTING)
; References: 1,20,41,47
MID 194 19401 19401 19401 19404 19405 19406
;
; Material: MAGNESIUM ALLOY MAGNOX A12(X) (WROUGHT)
; References: 47
MID 195 19501 19501 19501 19504 19505 19506
;
; Material: MAGNESIUM ALLOY M1(AC) (CASTING)
; References: 14,47
MID 196 19601 19601 19601 19604 19605 19606
;
; Material: MAGNESIUM ALLOY M1(X,S) (WROUGHT)
; References: 14,47
MID 197 19701 19701 19701 19704 19705 19706
;
; Material: MAGNESIUM ALLOY M1A (WROUGHT)
; References: 41
MID 198 19801 19801 19801 19804 19805 19806
;
; Material: MAGNESIUM ALLOY PE (WROUGHT)
; References: 41
MID 199 19901 19901 19901 19904 19905 19906
;
; Material: MAGNESIUM ALLOY ZA(AC) (CASTING)
; References: 47
MID 200 20001 20001 20001 20004 20005 20006
;
; Material: MAGNESIUM ALLOY ZE10A(O,H24) (WROUGHT)
; References: 41
MID 201 20101 20101 20101 20104 20105 20106
;
; Material: MAGNESIUM ALLOY ZE41A(T5,HT) (CASTING)
; References: 20,41,47
MID 202 20201 20201 20201 20204 20205 20206
;
; Material: MAGNESIUM ALLOY ZH42 (CASTING)
; References: 41
MID 203 20301 20301 20301 20304 20305 20306
;
; Material: MAGNESIUM ALLOY ZH62A(AC),TZ6 (CASTING)
; References: 20,41,47
MID 204 20401 20401 20401 20404 20405 20406
;
; Material: MAGNESIUM ALLOY ZK20A (WROUGHT)
; References: 20,41
MID 205 20501 20501 20501 20504 20505 20506
;
; Material: MAGNESIUM ALLOY ZK51A, H807 (CASTING)
; References: 20,41,47
MID 206 20601 20601 20601 20604 20605 20606
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 615
Materials References, Classification, Quality Code and Index
;
; Material: MAGNESIUM ALLOY ZK60A,B, ZW6 (CASTING)
; References: 1,14,20,41,47
MID 207 20701 20701 20701 20704 20705 20706
;
; Material: MAGNESIUM ALLOY ZRE0 (EZ30) (CASTING)
; References: 20
MID 208 20801 20801 20801 20804 20805 20806
;
; Material: MAGNESIUM ALLOY ZRE1(AA) (CASTING)
; References: 47
MID 209 20901 20901 20901 20904 20905 20906
;
; Material: MAGNESIUM ALLOY ZTY(X) (HK11) (WROUGHT)
; References: 20,47
MID 210 21001 21001 21001 21004 21005 21006
;
; Material: MAGNESIUM ALLOY ZW1(X) (ZK11) (WROUGHT)
; References: 47
MID 211 21101 21101 21101 21104 21105 21106
;
; Material: MAGNESIUM ALLOY ZW3(X) (ZK31) (WROUGHT)
; References: 47
MID 212 21201 21201 21201 21204 21205 21206
;
; Material: MAGNESIUM ALLOY (MG,AG2.5,CE2,ZR0.6)
; References: 47
MID 213 21301 21301 21301 21304 21305 21306
;
; Material: MAGNESIUM ALLOY 1959 (MG,CE4.33)
; References: 20
MID 214 21401 21401 21401 21404 21405 21406
;
; Material: MAGNESIUM ALLOY 1960 (MG,CE6.7)
; References: 20
MID 215 21501 21501 21501 21504 21505 21506
;
; Material: MAGNESIUM ALLOY 1961 (MG,CE11.85)
; References: 20
MID 216 21601 21601 21601 21604 21605 21606
;
; Material: MAGNESIUM ALLOY 1964 (MG,CE5,CO2,MN0.8)
; References: 20
MID 217 21701 21701 21701 21704 21705 21706
;
; Material: MAGNESIUM ALLOY 1992 (MG,CE4.45,CO3)
; References: 20
MID 218 21801 21801 21801 21804 21805 21806
;
; Material: IRON ALLOY INVAR (FE64, NI36)
; References: 6,41,47
MID 219 21901 21901 21901 21904 21905 21906
;
; Material: NICKEL ALLOY CALITE N
; References: 14
MID 220 22001 22001 22001 22004 22005 22006
;
; Material: NICKEL ALLOY A (NI99.4) (ANNEALED)
; References: 1,14,20
MID 221 22101 22101 22101 22104 22105 22106
;
; Material: NICKEL ALLOY CHLORIMET 3
; References: 14
MID 222 22201 22201 22201 22204 22205 22206
;
; Material: COPPER ALLOY CONSTANTAN (CU55, NI45)
; References: 1,2,14,41,47
MID 223 22301 22301 22301 22304 22305 22306
Main Index
616 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: NICKEL ALLOY CORROSIST
; References: 14
MID 224 22401 22401 22401 22404 22405 22406
;
; Material: NICKEL ALLOY DURANICKEL (AND -R) (SOFT)
; References: 1,14,47
MID 225 22501 22501 22501 22504 22505 22506
;
; Material: NICKEL ALLOY DURANICKEL (AND -R) (HARD)
; References: 1,14,47
MID 226 22601 22601 22601 22604 22605 22606
;
; Material: NICKEL ALLOY DURIMET 20 (CAST)
; References: 1
MID 227 22701 22701 22701 22704 22705 22706
;
; Material: NICKEL ALLOY HASTELLOY A (ANNEALED)
; References: 1,14,20
MID 228 22801 22801 22801 22804 22805 22806
;
; Material: NICKEL ALLOY HASTELLOY B
; References: 1,14,20,41,47
MID 229 22901 22901 22901 22904 22905 22906
;
; Material: NICKEL ALLOY HASTELLOY C
; References: 1,14,41,47
MID 230 23001 23001 23001 23004 23005 23006
;
; Material: NICKEL ALLOY HASTELLOY D
; References: 1,14,41,47
MID 231 23101 23101 23101 23104 23105 23106
;
; Material: NICKEL ALLOY HASTELLOY N AND INOR-8
; References: 20,41
MID 232 23201 23201 23201 23204 23205 23206
;
; Material: NICKEL ALLOY HASTELLOY R-235
; References: 1,14,20
MID 233 23301 23301 23301 23304 23305 23306
;
; Material: NICKEL ALLOY HASTELLOY X
; References: 1,14,20,41
MID 234 23401 23401 23401 23404 23405 23406
;
; Material: NICKEL ALLOY HY MU 80
; References: 14
MID 235 23501 23501 23501 23504 23505 23506
;
; Material: NICKEL ALLOY ILLIUM G
; References: 1,14,20,41,47
MID 236 23601 23601 23601 23604 23605 23606
;
; Material: NICKEL ALLOY ILLIUM R
; References: 1,14,41,47
MID 237 23701 23701 23701 23704 23705 23706
;
; Material: NICKEL ALLOY INCOLOY
; References: 1,14
MID 238 23801 23801 23801 23804 23805 23806
;
; Material: NICKEL ALLOY INCOLOY 901
; References: 1,20
MID 239 23901 23901 23901 23904 23905 23906
;
; Material: NICKEL ALLOY INCONEL (CAST)
; References: 1,14,20,41,47
MID 240 24001 24001 24001 24004 24005 24006
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 617
Materials References, Classification, Quality Code and Index
;
; Material: NICKEL ALLOY INCONEL (CAST)
; References: 1,14,20,41,47
MID 241 24101 24101 24101 24104 24105 24106
;
; Material: NICKEL ALLOY INCONEL W
; References: 1
MID 242 24201 24201 24201 24204 24205 24206
;
; Material: NICKEL ALLOY INCONEL 702 (ANNEALED)
; References: 1,20
MID 243 24301 24301 24301 24304 24305 24306
;
; Material: NICKEL ALLOY INCONEL X AND X-750
; References: 1,20,41
MID 244 24401 24401 24401 24404 24405 24406
;
; Material: NICKEL ALLOY INCONEL 600 (ANNEALED)
; References: 1,47
MID 245 24501 24501 24501 24504 24505 24506
;
; Material: NICKEL ALLOY INCONEL 700
; References: 1,14,20,41
MID 246 24601 24601 24601 24604 24605 24606
;
; Material: NICKEL ALLOY INCONEL 713C (CAST)
; References: 1,20
MID 247 24701 24701 24701 24704 24705 24706
;
; Material: NICKEL ALLOY MONEL (HOT-ROLLED)
; References: 1,14,41,44,47
MID 248 24801 24801 24801 24804 24805 24806
;
; Material: NICKEL ALLOY MONEL (COLD-DRAWN)
; References: 1,14,20,41
MID 249 24901 24901 24901 24904 24905 24906
;
; Material: NICKEL ALLOY MONEL 403 (HOT-ROLLED)
; References: 1
MID 250 25001 25001 25001 25004 25005 25006
;
; Material: NICKEL ALLOY MONEL (CAST)
; References: 1,41
MID 251 25101 25101 25101 25104 25105 25106
;
; Material: NICKEL ALLOY MONEL, H (AS CAST)
; References: 1,41
MID 252 25201 25201 25201 25204 25205 25206
;
; Material: NICKEL ALLOY MONEL WELDABLE ALLOY
; References: 1
MID 253 25301 25301 25301 25304 25305 25306
;
; Material: NICKEL ALLOY MONEL, K (ANNEALED)
; References: 1,14,20,41,44
MID 254 25401 25401 25401 25404 25405 25406
;
; Material: NICKEL ALLOY MONEL, H (CAST, VAR COMP)
; References: 1,20,41
MID 255 25501 25501 25501 25504 25505 25506
;
; Material: NICKEL ALLOY MONEL, KR (ANNEALED)
; References: 1,14
MID 256 25601 25601 25601 25604 25605 25606
;
; Material: NICKEL ALLOY MONEL 400
; References: 47
MID 257 25701 25701 25701 25704 25705 0
Main Index
618 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: NICKEL ALLOY MONEL, R (HOT-ROLLED)
; References: 1,20,41
MID 258 25801 25801 25801 25804 25805 25806
;
; Material: NICKEL ALLOY MONEL, S (CAST, ALL COND)
; References: 1,14,20
MID 259 25901 25901 25901 25904 25905 25906
;
; Material: NICKEL ALLOY M-252 (GE J-1500)
; References: 20
MID 260 26001 26001 26001 26004 26005 26006
;
; Material: NICKEL ALLOY NICHROME V (NI80, CR 20)
; References: 1,47
MID 261 26101 26101 26101 26104 26105 26106
;
; Material: NICKEL ALLOY NIMONIC DS
; References: 47
MID 262 26201 26201 26201 26204 26205 26206
;
; Material: NICKEL ALLOY NIMONIC 75
; References: 1,14,20
MID 263 26301 26301 26301 26304 26305 26306
;
; Material: NICKEL ALLOY NIMONIC 80
; References: 1,14,20,41,47
MID 264 26401 26401 26401 26404 26405 26406
;
; Material: NICKEL ALLOY NIMONIC 80A
; References: 1,20,41,47
MID 265 26501 26501 26501 26504 26505 26506
;
; Material: NICKEL ALLOY NIMONIC 90
; References: 1,14,20,41
MID 266 26601 26601 26601 26604 26605 26606
;
; Material: NICKEL ALLOY NIMONIC 95
; References: 20,47
MID 267 26701 26701 26701 26704 26705 26706
;
; Material: NICKEL ALLOY PERMANICKEL
; References: 1,14
MID 268 26801 26801 26801 26804 26805 26806
;
; Material: NICKEL ALLOY NIMONIC 105
; References: 47
MID 269 26901 26901 26901 26904 26905 26906
;
; Material: NICKEL ALLOY RENE 41
; References: 20,41
MID 270 27001 27001 27001 27004 27005 27006
;
; Material: NICKEL ALLOY NIMONIC 100
; References: 20
MID 271 27101 27101 27101 27104 27105 27106
;
; Material: NICKEL ALLOY UDIMET 500 (WROUGHT)
; References: 1,20,41
MID 272 27201 27201 27201 27204 27205 27206
;
; Material: NICKEL ALLOY WASPALLOY
; References: 1,20,41
MID 273 27301 27301 27301 27304 27305 27306
;
; Material: NICKEL ALLOY 330 (NI99.55) (ANNEALED)
; References: 1
MID 274 27401 27401 27401 27404 27405 27406
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 619
Materials References, Classification, Quality Code and Index
;
; Material: NICKEL ALLOY (NI62,CR12,FE26)
; References: 2,41
MID 275 27501 27501 27501 27504 27505 0
;
; Material: NICKEL ALLOY (NI60,CR16,FE24)
; References: 41
MID 276 27601 27601 27601 27604 27605 0
;
; Material: NICKEL ALLOY (NI35,CR20,FE45)
; References: 41
MID 277 27701 27701 27701 27704 27705 0
;
; Material: NICKEL ALLOY (NI99.5) LOW C, 220, 225
; References: 1,14
MID 278 27801 27801 27801 27804 27805 27806
;
; Material: NICKEL ALLOY D AND E
; References: 1
MID 279 27901 27901 27901 27904 27905 27906
;
; Material: COBALT ALLOY HE-1049
; References: 20
MID 280 28001 28001 28001 28004 28005 28006
;
; Material: COBALT ALLOY HS-21 (AS CAST)
; References: 1,14,20,41
MID 281 28101 28101 28101 28104 28105 28106
;
; Material: COBALT ALLOY HS-21 (AGED)
; References: 1,14,20,41
MID 282 28201 28201 28201 28204 28205 28206
;
; Material: COBALT ALLOY HS-23
; References: 14,20
MID 283 28301 28301 28301 28304 28305 28306
;
; Material: COBALT ALLOY HS-25 (L-605) (WROUGHT)
; References: 1,14,41
MID 284 28401 28401 28401 28404 28405 28406
;
; Material: COBALT ALLOY HS-27 (AS CAST)
; References: 14,20
MID 285 28501 28501 28501 28504 28505 28506
;
; Material: COBALT ALLOY HS-30 (422-19) (AS CAST)
; References: 14,20
MID 286 28601 28601 28601 28604 28605 28606
;
; Material: COBALT ALLOY HS-31 (X-40) (AS CAST)
; References: 1,14,20,41
MID 287 28701 28701 28701 28704 28705 28706
;
; Material: COBALT ALLOY HS-36 (CAST)
; References: 1,14,20
MID 288 28801 28801 28801 28804 28805 28806
;
; Material: COBALT ALLOY JESSOP G-32
; References: 20
MID 289 28901 28901 28901 28904 28905 28906
;
; Material: COBALT ALLOY J-1570
; References: 20
MID 290 29001 29001 29001 29004 29005 29006
;
; Material: COBALT ALLOY K-42B
; References: 14
MID 291 29101 29101 29101 29104 29105 29106
Main Index
620 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: COBALT ALLOY MULTIMET (N-155) (WROUGHT)
; References: 1,14,20,41
MID 292 29201 29201 29201 29204 29205 29206
;
; Material: COBALT ALLOY MULTIMET (N-155) (LOW C)
; References: 1,14,20,41
MID 293 29301 29301 29301 29304 29305 29306
;
; Material: COBALT ALLOY S-590 (WROUGHT)
; References: 14,41
MID 294 29401 29401 29401 29404 29405 29406
;
; Material: COBALT ALLOY S-816 (WROUGHT)
; References: 1,14,20,41
MID 295 29501 29501 29501 29504 29505 29506
;
; Material: COBALT ALLOY V-36 (WROUGHT)
; References: 41
MID 296 29601 29601 29601 29604 29605 29606
;
; Material: COBALT ALLOY WI-52
; References: 20
MID 297 29701 29701 29701 29704 29705 29706
;
; Material: COBALT ALLOY WI-52 (CR COATED SAMPLE)
; References: 20
MID 298 29801 29801 29801 29804 29805 29806
;
; Material: COBALT ALLOY (CO64,CR30,W6)
; References: 20
MID 299 29901 29901 29901 29904 29905 29906
;
; Material: TITANIUM ALLOY (TI BAL, AL2, MN2)
; References: 20
MID 300 30001 30001 30001 30004 30005 30006
;
; Material: TITANIUM ALLOY (TI BAL, AL4, V2, MO1)
; References: 20
MID 301 30101 30101 30101 30104 30105 30106
;
; Material: TITANIUM ALLOY (TI BAL, AL4, CU2, ZR2)
; References: 20
MID 302 30201 30201 30201 30204 30205 30206
;
; Material: TITANIUM ALLOY (TI BAL, AL4, V3, MO1.5)
; References: 20
MID 303 30301 30301 30301 30304 30305 30306
;
; Material: TITANIUM ALLOY (TI BAL, AL4, V1, MO0.6)
; References: 20
MID 304 30401 30401 30401 30404 30405 30406
;
; Material: TITANIUM ALLOY HYLITE 40 C130AM,RC130B
; References: 1,20,41
MID 305 30501 30501 30501 30504 30505 30506
;
; Material: TITANIUM ALLOY HYLITE 50 (IMI550)
; References: 20,45
MID 306 30601 30601 30601 30604 30605 30606
;
; Material: TITANIUM ALLOY HYLITE 51 (IMI551)
; References: 45
MID 307 30701 30701 30701 30704 30705 30706
;
; Material: TITANIUM ALLOY (TI BAL, AL4, ZR3.5)
; References: 20
MID 308 30801 30801 30801 30804 30805 30806
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 621
Materials References, Classification, Quality Code and Index
;
; Material: TITANIUM ALLOY (TI BAL, AL4, CU4, SN2)
; References: 20
MID 309 30901 30901 30901 30904 30905 30906
;
; Material: TITANIUM ALLOY (TI BAL, AL4, MO3, V1)
; References: 20
MID 310 31001 31001 31001 31004 31005 31006
;
; Material: TITANIUM ALLOY TI155A (AL5,FE2,CR1,MO1)
; References: 1,20
MID 311 31101 31101 31101 31104 31105 31106
;
; Material: TITANIUM ALLOY (TI BAL, AL5, SN2.5)
; References: 41,45
MID 312 31201 31201 31201 31204 31205 31206
;
; Material: TITANIUM ALLOY (TI BAL, AL5, SN5, ZR5)
; References: 45
MID 313 31301 31301 31301 31304 31305 31306
;
; Material: TITANIUM ALLOY (TI BAL, AL6, V4)
; References: 20,37,45
MID 314 31401 31401 31401 31404 31405 31406
;
; Material: TITANIUM ALLOY (TI BAL, AL8, MO1, V1)
; References: 45
MID 315 31501 31501 31501 31504 31505 31506
;
; Material: TITANIUM ALLOY TI150A (CR2.7, FE1.4)
; References: 20
MID 316 31601 31601 31601 31604 31605 31606
;
; Material: TITANIUM ALLOY (TI BAL, CR3.4, MO2.1)
; References: 20
MID 317 31701 31701 31701 31704 31705 31706
;
; Material: TITANIUM ALLOY TI140A (FE2, CR2, MO2)
; References: 20
MID 318 31801 31801 31801 31804 31805 31806
;
; Material: TITANIUM ALLOY C100M (RC130A) (MN7.9)
; References: 20
MID 319 31901 31901 31901 31904 31905 31906
;
; Material: TITANIUM ALLOY (TI BAL, SN4.8, AL4.5)
; References: 20
MID 320 32001 32001 32001 32004 32005 32006
;
; Material: TITANIUM ALLOY (TI BAL, SN5.5, AL2)
; References: 20
MID 321 32101 32101 32101 32104 32105 32106
;
; Material: TITANIUM ALLOY HYLITE 65 (IMI)
; References: 45
MID 322 32201 32201 32201 32204 32205 32206
;
; Material: TITANIUM ALLOY HYLITE 60 (IMI)
; References: 20,45
MID 323 32301 32301 32301 32304 32305 32306
;
; Material: TITANIUM ALLOY HYLITE 55 (IMI)
; References: 20,45
MID 324 32401 32401 32401 32404 32405 32406
;
; Material: TITANIUM ALLOY IMI 680 (SN11, MO4, AL2)
; References: 45
MID 325 32501 32501 32501 32504 32505 32506
Main Index
622 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: TITANIUM ALLOY IMI 679 (SN11, ZR5, AL2)
; References: 45
MID 326 32601 32601 32601 32604 32605 32606
;
; Material: TITANIUM ALLOY (TI BAL, V15, AL2.8)
; References: 20
MID 327 32701 32701 32701 32704 32705 32706
;
; Material: TITANIUM ALLOY (TI BAL, V14, CR10, AL4)
; References: 20
MID 328 32801 32801 32801 32804 32805 32806
;
; Material: TITANIUM ALLOY (TI BAL, ZR3, AL2)
; References: 20
MID 329 32901 32901 32901 32904 32905 32906
;
; Material: IRON, GREY CAST, FERRITIC (2.3-3.0 C)
; References: 1,2,6,20,27,33,46
MID 330 33001 33001 33001 33004 33005 33006
;
; Material: IRON, GREY CAST, FERRITIC (3.2-3.8 C)
; References: 1,2,6,20,27,33,46
MID 331 33101 33101 33101 33104 33105 33106
;
; Material: IRON, GREY CAST, PEARLITIC (2.3-3.0 C)
; References: 1,2,6,20,27,33,46
MID 332 33201 33201 33201 33204 33205 33206
;
; Material: IRON, GREY CAST, PEARLITIC (3.0-3.2 C)
; References: 1,2,6,20,27,33,46
MID 333 33301 33301 33301 33304 33305 33306
;
; Material: IRON, GREY CAST, PEARLITIC (3.4 C)
; References: 1,2,6,20,27,33,46
MID 334 33401 33401 33401 33404 33405 33406
;
; Material: IRON, GREY CAST, PEARLITIC (3.7-3.8 C)
; References: 1,2,6,20,27,33,46
MID 335 33501 33501 33501 33504 33505 33506
;
; Material: IRON, GREY CAST, PEARLITIC (4.12 C)
; References: 1,2,6,20,27,33,46
MID 336 33601 33601 33601 33604 33605 33606
;
; Material: IRON, DUCTILE (0.06 MG)
; References: 1,6
MID 337 33701 33701 33701 33704 33705 33706
;
; Material: IRON, DUCTILE (MG CONTAINING)
; References: 1
MID 338 33801 33801 33801 33804 33805 33806
;
; Material: IRON, DUCTILE (MG CONTAINING, HEAT RES)
; References: 1
MID 339 33901 33901 33901 33904 33905 33906
;
; Material: IRON, NODULAR CAST, FERRITIC BASE
; References: 1,2,20
MID 340 34001 34001 34001 34004 34005 34006
;
; Material: IRON, NODULAR CAST, PEARLITIC BASE
; References: 1,2,20
MID 341 34101 34101 34101 34104 34105 34106
;
; Material: IRON, NI-HARD TYPES 1 AND 2 (KOVAR)
; References: 1,20
MID 342 34201 34201 34201 34204 34205 34206
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 623
Materials References, Classification, Quality Code and Index
;
; Material: IRON, NI-RESIST, TYPES 1 AND 2 (CAST)
; References: 1,20
MID 343 34301 34301 34301 34304 34305 34306
;
; Material: IRON, NI-RESIST, TYPE 3 (CAST)
; References: 1
MID 344 34401 34401 34401 34404 34405 34406
;
; Material: IRON, NI-RESIST, TYPE 4 (CAST)
; References: 1
MID 345 34501 34501 34501 34504 34505 34506
;
; Material: IRON, NI-RESIST, TYPE D2 (CAST)
; References: 1
MID 346 34601 34601 34601 34604 34605 34606
;
; Material: IRON, MALLEABLE (2.5 C)
; References: 1,6
MID 347 34701 34701 34701 34704 34705 0
;
; Material: IRON, WROUGHT (VARIOUS)
; References: 1,2,6,27
MID 348 34801 34801 34801 34804 34805 34806
;
; Material: IRON, NI-TENSYLIRON (CAST, HEAT TREAT)
; References: 1
MID 349 34901 34901 34901 34904 34905 34906
;
; Material: STEEL, ALLOY AND MILD (4130, 4340)
; References: 6,41,46
MID 350 35001 35001 35001 35004 35005 35006
;
; Material: STEEL, ALLOY, CAST
; References: 6
MID 351 35101 35101 35101 35104 35105 35106
;
; Material: STEEL, FREE CUTTING, EUTECTOID
; References: 2,4,6,20,41
MID 352 35201 35201 35201 35204 35205 35206
;
; Material: STEEL, CARBON, TYPE 1020 (0.2 - 0.6 C)
; References: 1,20,37
MID 353 35301 35301 35301 35304 35305 35306
;
; Material: STEEL, HIGH SPEED (M1, M10, M-2, TI)
; References: 20
MID 354 35401 35401 35401 35404 35405 35406
;
; Material: STEEL, STAINLESS 201 AND 202
; References: 1
MID 355 35501 35501 35501 35504 35505 35506
;
; Material: STEEL, STAINLESS (CR 16-26, NI 8-36)
; References: 1,2,4,6,20,37
MID 356 35601 35601 35601 35604 35605 35606
;
; Material: STEEL, STAINLESS 304
; References: 1,4,37
MID 357 35701 35701 35701 35704 35705 35706
;
; Material: STEEL, STAINLESS 321 AND 347
; References: 1,2,4,20,37,14
MID 358 35801 35801 35801 35804 35805 35806
;
; Material: STEEL, STAINLESS (CR 12-13, NI 0-3)
; References: 1,2,4,14,20
MID 359 35901 35901 35901 35904 35905 35906
Main Index
624 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: STEEL, STAINLESS 430, 430F, AND 431
; References: 1,2,4,6,20,14
MID 360 36001 36001 36001 36004 36005 36006
;
; Material: STEEL, STAINLESS 446
; References: 1,14,20
MID 361 36101 36101 36101 36104 36105 36106
;
; Material: STEEL, STAINLESS 501 AND 502
; References: 2,4
MID 362 36201 36201 36201 36204 36205 36206
;
; Material: STEEL, STAINLESS 17-4PH
; References: 20,14
MID 363 36301 36301 36301 36304 36305 36306
;
; Material: STEEL, STAINLESS 17-7PH
; References: 20,14
MID 364 36401 36401 36401 36404 36405 36406
;
; Material: STEEL, ULTRA HIGH STRENGTH TYPE 300-M
; References: 1
MID 365 36501 36501 36501 36504 36505 36506
;
; Material: STEEL, STAINLESS 19-9DL
; References: 41
MID 366 36601 36601 36601 36604 36605 0
;
; Material: STEEL, STAINLESS HW (CAST)
; References: 1
MID 367 36701 36701 36701 36704 36705 36706
;
; Material: STEEL, STAINLESS HU (CAST)
; References: 1
MID 368 36801 36801 36801 36804 36805 36806
;
; Material: STEEL, STAINLESS HT (CAST)
; References: 1
MID 369 36901 36901 36901 36904 36905 36906
;
; Material: STEEL, STAINLESS CN-7M (CAST)
; References: 1
MID 370 37001 37001 37001 37004 37005 37006
;
; Material: STEEL, STAINLESS HF (CAST)
; References: 1
MID 371 37101 37101 37101 37104 37105 37106
;
; Material: STEEL, STAINLESS HA (CAST)
; References: 1
MID 372 37201 37201 37201 37204 37205 37206
;
; Material: STEEL, STAINLESS HC, HD (CAST)
; References: 1
MID 373 37301 37301 37301 37304 37305 37306
;
; Material: STEEL, STAINLESS CA15, CA40 (CAST)
; References: 1
MID 374 37401 37401 37401 37404 37405 37406
;
; Material: STEEL, STAINLESS CB30, CC50 (CAST)
; References: 1
MID 375 37501 37501 37501 37504 37505 37506
;
; Material: STEEL, STAINLESS HH, HL, HK (CAST)
; References: 1
MID 376 37601 37601 37601 37604 37605 37606
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 625
Materials References, Classification, Quality Code and Index
;
; Material: STEEL, STAINLESS HE (CAST)
; References: 1
MID 377 37701 37701 37701 37704 37705 37706
;
; Material: STEEL, STAINLESS CF (CAST)
; References: 1
MID 378 37801 37801 37801 37804 37805 37806
;
; Material: STEEL, STAINLESS CK, CH, HI (CAST)
; References: 1
MID 379 37901 37901 37901 37904 37905 37906
;
; Material: CHROME-NICKEL-IRON SUPERALLOYS
; References: 6
MID 380 38001 38001 38001 38004 38005 0
;
; Material: BERYLLIUM ALLOY (BE96.5) (AS RECEIVED)
; References: 20
MID 381 38101 38101 38101 38104 38105 38106
;
; Material: BERYLLIUM ALLOY (BE96.5) (ANNEALED)
; References: 20
MID 382 38201 38201 38201 38204 38205 38206
;
; Material: BERYLLIUM ALLOY (BE98.5) (AS RECEIVED)
; References: 20
MID 383 38301 38301 38301 38304 38305 38306
;
; Material: BERYLLIUM ALLOY (BE98.5) (ANNEALED)
; References: 20
MID 384 38401 38401 38401 38404 38405 38406
;
; Material: BERYLLIUM ALLOY (BE99.5)
; References: 20
MID 385 38501 38501 38501 38504 38505 38506
;
; Material: LEAD, ANTIMONIAL (PB, SB 4-6) (HARD)
; References: 1,6,41
MID 386 38601 38601 38601 38604 38605 38606
;
; Material: LEAD, ANTIMONIAL (PB, SB 8-9)
; References: 1,6,41
MID 387 38701 38701 38701 38704 38705 38706
;
; Material: INDIUM ALLOY (IN25, SN37.5, PB37.5)
; References: 36
MID 388 38801 38801 38801 38804 38805 38806
;
; Material: LEAD ALLOY (PB39.2, SN60.8) (SOLDER)
; References: 34,41
MID 389 38901 38901 38901 38904 38905 38906
;
; Material: LEAD ALLOY (PB50, SN50) (SOLDER)
; References: 1,41
MID 390 39001 39001 39001 39004 39005 39006
;
; Material: LEAD ALLOY (PB60, SN40) (SOLDER)
; References: 1,41
MID 391 39101 39101 39101 39104 39105 39106
;
; Material: MOLYBDENUM ALLOY (MO99.5, TI0.5)
; References: 1,6,41
MID 392 39201 39201 39201 39204 39205 39206
;
; Material: MOLYBDENUM ALLOY (MO BAL, FE 0.25)
; References: 20
MID 393 39301 39301 39301 39304 39305 39306
Main Index
626 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: MOLYBDENUM ALLOY (MO70, W30)
; References: 20
MID 394 39401 39401 39401 39404 39405 39406
;
; Material: COLOMBIUM ALLOY (CB61,TA28,W10,ZR0.5)
; References: 20
MID 395 39501 39501 39501 39504 39505 39506
;
; Material: COLOMBIUM ALLOY (CB85, TI10, ZR5)
; References: 20
MID 396 39601 39601 39601 39604 39605 39606
;
; Material: COLOMBIUM ALLOY (CB95, TA5)
; References: 20
MID 397 39701 39701 39701 39704 39705 39706
;
; Material: COLOMBIUM ALLOY (CB80, W15, MO5)
; References: 20
MID 398 39801 39801 39801 39804 39805 39806
;
; Material: PLUTONIUM ALLOY (DELTA PHASE)
; References: 20,27,31,44
MID 399 39901 39901 39901 39904 39905 39906
;
; Material: SILVER ALLOYS, STERLING AND COIN
; References: 1
MID 400 40001 40001 40001 40004 40005 40006
;
; Material: TANTALUM ALLOY (TA90, W10)
; References: 20,36
MID 401 40101 40101 40101 40104 40105 40106
;
; Material: TANTALUM ALLOY (TA99.5, NB0.5)
; References: 20
MID 402 40201 40201 40201 40204 40205 40206
;
; Material: TANTALUM ALLOY (TA98, CU0.7, ZR0.7)
; References: 20
MID 403 40301 40301 40301 40304 40305 40306
;
; Material: TANTALUM ALLOY (TA62, NB30, V7.5)
; References: 20
MID 404 40401 40401 40401 40404 40405 40406
;
; Material: TANTALUM ALLOY (TA89, W9, HF2)
; References: 20
MID 405 40501 40501 40501 40504 40505 40506
;
; Material: TUNGSTEN ALLOY (W75, RE25)
; References:
MID 406 40601 40601 40601 40604 40605 40606
;
; Material: TUNGSTEN ALLOY (W90, NI6, CU2-4)
; References: 20
MID 407 40701 40701 40701 40704 40705 40706
;
; Material: MULBERRY (U90, NB7.5, ZR2.5)
; References: 34,36,37
MID 408 40801 40801 40801 40804 40805 40806
;
; Material: URANIUM ALLOY (U90, MO10)
; References: 20,35,36
MID 409 40901 40901 40901 40904 40905 40906
;
; Material: URANIUM ALLOY (U82, ZR18)
; References: 20,34
MID 410 41001 41001 41001 41004 41005 41006
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 627
Materials References, Classification, Quality Code and Index
;
; Material: URANIUM ALLOY (U96, NB4)
; References: 20,34
MID 411 41101 41101 41101 41104 41105 41106
;
; Material: URANIUM ALLOY (U94.4, CR5.6) (EUTECTIC)
; References: 20
MID 412 41201 41201 41201 41204 41205 41206
;
; Material: URANIUM ALLOY (U97, FS3)
; References: 20
MID 413 41301 41301 41301 41304 41305 41306
;
; Material: URANIUM ALLOY (U90, FS10)
; References: 20
MID 414 41401 41401 41401 41404 41405 41406
;
; Material: URANIUM ALLOY (U93, FS5, ZR2)
; References: 20
MID 415 41501 41501 41501 41504 41505 41506
;
; Material: URANIUM ALLOY (U98.5, ZR1.5)
; References: 20
MID 416 41601 41601 41601 41604 41605 41606
;
; Material: URANIUM ALLOY (U95, ZR5)
; References: 20 3
MID 417 41701 41701 41701 41704 41705 41706
;
; Material: ZILLOY 15
; References: 1,6,41
MID 418 41801 41801 41801 41804 41805 41806
;
; Material: ZINC ALLOY ASTM B69
; References: 1,6,41,51
MID 419 41901 41901 41901 41904 41905 41906
;
; Material: ZINC-ALUMINUM ALLOY ASTM 23
; References: 1,6,41
MID 420 42001 42001 42001 42004 42005 42006
;
; Material: ZINC-ALUMINUM-COPPER ALLOY ASTM 25
; References: 1,6,41
MID 421 42101 42101 42101 42104 42105 42106
;
; Material: ZIRCONIUM ALLOYS ZIRCALLOY 2 AND 3
; References: 1,6,14
MID 422 42201 42201 42201 42204 42205 42206
;
; Material: ZIRCONIUM ALLOY 3ZI (ZR97,AL1,SN1,MO1)
; References: 20
MID 423 42301 42301 42301 42304 42305 42306
;
; Material: DANDELION 35
; References: 34,36
MID 424 42401 42401 42401 42404 42405 0
;
; Material: ALUMINUM OXIDE (AL2O3) (POLYXTAL 100 D)
; References: 1,20,27,32,47,48,51
MID 425 42501 42501 42501 42504 42505 42506
;
; Material: ALUMINUM OXIDE (AL2O3) (POLYXTAL, 55 D)
; References: 1,20,27,32,47,48,51
MID 426 42601 42601 42601 42604 42605 42606
;
; Material: ALUMINUM OXIDE (AL2O3) (SINGLE XTAL)
; References: 1,20,27,32,47,48,51
MID 427 42701 42701 42701 42704 42705 42706
Main Index
628 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: ALUMINUM OXIDE (AL2O3) (FOAM, D = 0.5)
; References: 1,20,27,32,47,48,51
MID 428 42801 42801 42801 42804 42805 42806
;
; Material: ALUMINUM OXIDE (AL2O3) (FOAM, D = 1.9)
; References: 1,20,27,32,47,48,51
MID 429 42901 42901 42901 42904 42905 42906
;
; Material: BERYLLIUM OXIDE (BEO) (96 PC DENS)
; References: 14,20,27,36,43,44,47,48,51
MID 430 43001 43001 43001 43004 43005 43006
;
; Material: BERYLLIUM OXIDE (BEO) (76 PC DENS)
; References: 14,20,27,36,43,44,47,48,51
MID 431 43101 43101 43101 43104 43105 43106
;
; Material: CALCIUM OXIDE (CAO) (PRESSED, 91 DENS)
; References: 1,20,27,47,48,51
MID 432 43201 43201 43201 43204 43205 43206
;
; Material: CARBON DIOXIDE
; References: 1,2,27
MID 433 43301 43301 43301 43304 43305 43306
;
; Material: CALCIUM OXIDE (CAO) (PACKED PWD, 50 D)
; References: 1,20,27,47,48
MID 434 43401 43401 43401 43404 43405 43406
;
; Material: CARBON MONOXIDE
; References: 1,27
MID 435 43501 43501 43501 43504 43505 43506
;
; Material: CERIUM OXIDE (CEO2) (PRSD, SNTRD, 86 D)
; References: 1,20,47
MID 436 43601 43601 43601 43604 43605 43606
;
; Material: COBALT OXIDE (COO)
; References: 20,27,47,48
MID 437 43701 43701 43701 43704 43705 43706
;
; Material: COPPER OXIDE (CUO) (TENORITE)
; References: 1,20,27,47,51
MID 438 43801 43801 43801 43804 43805 43806
;
; Material: GADOLINIUM OXIDE (GD2O3) (MONOC) (98 D)
; References: 20,47,48
MID 439 43901 43901 43901 43904 43905 0
;
; Material: HAFNIUM OXIDE (HFO2) (MONOC) (94 D)
; References: 20,27,48
MID 440 44001 44001 44001 44004 44005 44006
;
; Material: HEMATITE (FE2O3)
; References: 1,27,32,47,48,51
MID 441 44101 44101 44101 44104 44105 0
;
; Material: IRON OXIDE (FEO.FE2O3) (MAGNATITE)
; References: 20,27,47,51
MID 442 44201 44201 44201 44204 44205 44206
;
; Material: LEAD OXIDE (PBO) (YELLOW)
; References: 1,20,27,32,47
MID 443 44301 44301 44301 44304 44305 44306
;
; Material: MAGNESIUM OXIDE (MGO) (SINGLE CRYSTAL)
; References: 1,20,27,47,48
MID 444 44401 44401 44401 44404 44405 44406
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 629
Materials References, Classification, Quality Code and Index
;
; Material: MAGNESIUM OXIDE (MGO) (POLYXTAL, 100 D)
; References: 1,20,27,47,48,51
MID 445 44501 44501 44501 44504 44505 44506
;
; Material: MANGANESE OXIDE (MNO) (SINGLE XTAL)
; References: 1,27,48
MID 446 44601 44601 44601 44604 44605 44606
;
; Material: MANGANESE OXIDE (MN3O4) (87 PC DENSE)
; References: 20,27,48,51
MID 447 44701 44701 44701 44704 44705 44706
;
; Material: NICKEL OXIDE (NIO) (SINGLE XTAL)
; References: 20,27,32,47,48,51
MID 448 44801 44801 44801 44804 44805 44806
;
; Material: NICKEL OXIDE (NIO) (POLYXTAL, 88-100 D)
; References: 20,27,32,47,48,51
MID 449 44901 44901 44901 44904 44905 44906
;
; Material: NICKEL OXIDE (NIO) (POLYXTAL, 68-74 D)
; References: 20,27,32,47,48,51
MID 450 45001 45001 45001 45004 45005 45006
;
; Material: NITRIC OXIDE (NO) (GAS)
; References: 1,27
MID 451 45101 45101 45101 45104 45105 0
;
; Material: FUSED SILICA GLASS
; References: 1,20,27,47,511,20,27,47,51
MID 452 45201 45201 45201 45204 45205 45206
;
; Material: QUARTZ CRYSTAL, C AXIS (SIO2)
; References: 1,2,20,27,37,47,51
MID 453 45301 45301 45301 45304 45305 45306
;
; Material: QUARTZ CRYSTAL, A AXIS (SIO2)
; References: 1,2,20,27,37,47,51
MID 454 45401 45401 45401 45404 45405 45406
;
; Material: SILICON OXIDE (SIO2) (FOAM, 1 ATM AIR)
; References: 1,20,27,47
MID 455 45501 45501 45501 45504 45505 45506
;
; Material: SULFUR DIOXIDE (SO2) (GAS)
; References: 1
MID 456 45601 45601 45601 45604 45605 0
;
; Material: THORIUM OXIDE (THO2) (96-100 PC DENSE)
; References: 1,20,27,47,48,51
MID 457 45701 45701 45701 45704 45705 45706
;
; Material: TIN OXIDE (SNO2) (93-95 PC DENSE)
; References: 1,20,27,47,48
MID 458 45801 45801 45801 45804 45805 45806
;
; Material: TITANIUM OXIDE (TIO2) (RUTILE, C AXIS)
; References: 1,20,27,32,47,48,51
MID 459 45901 45901 45901 45904 45905 45906
;
; Material: TITANIUM OXIDE (TIO2) (RUTILE, A AXIS)
; References: 1,20,27,32,47,48,51
MID 460 46001 46001 46001 46004 46005 46006
;
; Material: TITANIUM OXIDE (TIO2) (RUTILE, 100 D)
; References: 1,20,27,32,47,48,51
MID 461 46101 46101 46101 46104 46105 46106
Main Index
630 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: TUNGSTEN OXIDE (WO3) (POLYXTAL. POROUS)
; References: 20,27,47,48
MID 462 46201 46201 46201 46204 46205 46206
;
; Material: URANIUM OXIDE (UO2) (SINGLE CRYSTAL)
; References: 20,27,47,48,51
MID 463 46301 46301 46301 46304 46305 0
;
; Material: URANIUM OXIDE (UO2) (POLYXTAL, 97 DENS)
; References: 20,27,47,48,51
MID 464 46401 46401 46401 46404 46405 0
;
; Material: URANIUM OXIDE (U3O8) (PRSD AT 4200 PSI)
; References: 1,20,27,47,48
MID 465 46501 46501 46501 46504 46505 0
;
; Material: URANIUM OXIDE (U3O8) (PRSD AT 100 PSI)
; References: 1,20,27,47,48
MID 466 46601 46601 46601 46604 46605 0
;
; Material: YTTRIUM OXIDE (Y2O3) (96-100 PC DENSE)
; References: 20,27,47,48
MID 467 46701 46701 46701 46704 46705 46706
;
; Material: ZINC OXIDE (ZNO) (PRSD, FIRED, 100 D)
; References: 1,20,27,47,48,51
MID 468 46801 46801 46801 46804 46805 46806
;
; Material: ZIRCONIUM OXIDE (ZRO2) (MONOC., 100 D)
; References: 1,20,27,47,48,51
MID 469 46901 46901 46901 46904 46905 46906
;
; Material: ZIRCONIUM OXIDE (ZRO2 96, CAO 6, 91 D)
; References: 1,20,27,47,48,51
MID 470 47001 47001 47001 47004 47005 47006
;
; Material: STEAM (H2O) (GAS) (1 ATM)
; References: 1,2,14,27,46
MID 471 47101 47101 47101 47104 47105 47106
;
; Material: STEAM (H2O) (GAS) (SATD)
; References: 1,2,14,27,46
MID 472 47201 47201 47201 47204 47205 0
;
; Material: WATER (H2O) (LIQUID)
; References: 2,14,27,46
MID 473 47301 47301 47301 47304 47305 47306
;
; Material: ICE (H2O) (SOLID)
; References: 27,46,51
MID 474 47401 47401 47401 47404 47405 47406
;
; Material: DEUTERIUM OXIDE (D2O) (LIQUID)
; References: 14,27
MID 475 47501 47501 47501 47504 47505 47506
;
; Material: BARIUM TITANATE (BAO.TIO2) (100 D)
; References: 20,27,48
MID 476 47601 47601 47601 47604 47605 0
;
; Material: BARIUM TITANATE (BAO.TIO2) (SINTERED)
; References: 20,27,48
MID 477 47701 47701 47701 47704 47705 0
;
; Material: BARIUM TITANATE (BAO.TIO2) (+MN,NB OX)
; References: 20,27,48
MID 478 47801 47801 47801 47804 47805 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 631
Materials References, Classification, Quality Code and Index
;
; Material: CALCIUM TITANATE (CAO.TIO2)
; References: 20,27,48,51
MID 479 47901 47901 47901 47904 47905 0
;
; Material: COBALT NICKEL OXIDE (46COO.46NIO.8LIO)
; References: 20,27
MID 480 48001 48001 48001 48004 48005 0
;
; Material: COPPER LITHIUM OXIDE (96CUO.4LIO)
; References: 20,27
MID 481 48101 48101 48101 48104 48105 0
;
; Material: LITHIUM NICKEL OXIDE (5LIO.95NIO)
; References: 20,27
MID 482 48201 48201 48201 48204 48205 0
;
; Material: MAGNESIUM ALUMINATE (MGO.AL2O3) (XTAL)
; References: 20,27,47,48,51
MID 483 48301 48301 48301 48304 48305 0
;
; Material: MAGNESIUM ALUMINATE (MGO.AL2O3) (100 D)
; References: 20,27,47,48,51
MID 484 48401 48401 48401 48404 48405 0
;
; Material: NICKEL ZINC FERRITE (NI(ZN)O.FE2O3)
; References: 20
MID 485 48501 48501 48501 48504 48505 0
;
; Material: POTASSIUM CHROMATE (K2O.2CRO3) (S AXIS)
; References: 1,27
MID 486 48601 48601 48601 48604 48605 48606
;
; Material: POTASSIUM CHROMATE (K2O.2CRO3) (M AXIS)
; References: 1,27
MID 487 48701 48701 48701 48704 48705 48706
;
; Material: STRONTIUM TITANATE (SRO.TIO2) (100 D)
; References: 20,48
MID 488 48801 48801 48801 48804 48805 0
;
; Material: STRONTIUM TITANATE (SRO.TIO2) (80 D)
; References: 20,48
MID 489 48901 48901 48901 48904 48905 0
;
; Material: PLUTONIUM URANIUM OXIDE (PUO2.4UO2) SEE
; References: 53
MID 490 49001 49001 49001 49004 49005 0
;
; Material: ZINC FERRITE (ZNO.FE2O3) (PR, FRD, VAC)
; References: 20,27
MID 491 49101 49101 49101 49104 49105 0
;
; Material: ALUMINUM FLUOSILICATE (TOPAZ) (A-AXIS)
; References: 27,51
MID 492 49201 49201 49201 49204 49205 0
;
; Material: ALUMINUM FLUOSILICATE (TOPAZ) (C-AXIS)
; References: 27,51
MID 493 49301 49301 49301 49304 49305 0
;
; Material: ALUMINUM SILICATE (AL2O3.SIO2) (ORTHO)
; References: 20,27,47,51
MID 494 49401 49401 49401 49404 49405 0
;
; Material: ALUMINUM SILICATE (AL2O3.SIO2) (TRICL)
; References: 20,27,47,51
MID 495 49501 49501 49501 49504 49505 0
Main Index
632 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: ALUMINUM SILICATE (3AL2O3.2SIO2) (100D)
; References: 20,27,47,48,51
MID 496 49601 49601 49601 49604 49605 0
;
; Material: BERYL (3BEO.AL2O3.6SIO2)
; References: 20,27,51
MID 497 49701 49701 49701 49704 49705 0
;
; Material: BETA-SPODUMENE (LI2O.AL2O3.4SIO2) (TET)
; References: 20,27,51
MID 498 49801 49801 49801 49804 49805 0
;
; Material: CORDIERITE (2MGO.2AL2O3.5SIO2)
; References: 20,51
MID 499 49901 49901 49901 49904 49905 0
;
; Material: FORSTERITE (2MGO.SIO2) (100 PC DENSE)
; References: 1,20,27,51
MID 500 50001 50001 50001 50004 50005 50006
;
; Material: MAGNESIUM SILICATE (MGO.SIO2) (COMMERC)
; References: 1,20,27,51
MID 501 50101 50101 50101 50104 50105 0
;
; Material: ORTHOCLASE (K2O.AL2O3.6SIO2) (CRYSTAL)
; References: 27,51
MID 502 50201 50201 50201 50204 50205 0
;
; Material: ANALCITE (NA2O.AL2O3.4SIO2.4H2O) (XTAL)
; References: 27,51
MID 503 50301 50301 50301 50304 50305 0
;
; Material: ZIRCON (ZRO2.SIO2) (SINGLE CRYSTAL)
; References: 20,27,48,61
MID 504 50401 50401 50401 50404 50405 0
;
; Material: ZIRCONIUM SILICATE (ZRO2.SIO2) (100 D)
; References: 20,27,48,61
MID 505 50501 50501 50501 50504 50505 0
;
; Material: ALUMINUM NITRIDE (ALN) (PRS AXIS, 98 D)
; References: 20,27,47,48
MID 506 50601 50601 50601 50604 50605 0
;
; Material: BERYLLIUM NITRIDE (BE3N2) (PRSD 3.4 KB)
; References: 20,47
MID 507 50701 50701 50701 50704 50705 50706
;
; Material: BORON NITRIDE (BN) (PERP PR AXIS, 95 D)
; References: 20,27,36,47,48
MID 508 50801 50801 50801 50804 50805 0
;
; Material: BORON NITRIDE (BN) (PRS AXIS, 94 D)
; References: 20,27,36,47,48
MID 509 50901 50901 50901 50904 50905 0
;
; Material: BORON NITRIDE (BN 97, BN2O3 2) (PERP P)
; References: 20
MID 510 51001 51001 51001 51004 51005 0
;
; Material: BORON NITRIDE (BN 97, BN2O3 2) (PRS AX)
; References: 20
MID 511 51101 51101 51101 51104 51105 0
;
; Material: BORON NITRIDE (BN 80, C 20) (PRS AXIS)
; References: 20
MID 512 51201 51201 51201 51204 51205 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 633
Materials References, Classification, Quality Code and Index
;
; Material: CHROMIUM NITRIDE (CRN) (PRSD, 100 PC D)
; References: 27,47,48
MID 513 51301 51301 51301 51304 51305 0
;
; Material: CHROMIUM NITRIDE (CR2N) (PRSD, 100 D)
; References: 27,47,48
MID 514 51401 51401 51401 51404 51405 0
;
; Material: HAFNIUM NITRIDE (HFN) (HP STRD 78-92 D)
; References: 20,27,48
MID 515 51501 51501 51501 51504 51505 0
;
; Material: MOLYBDENUM NITRIDE (MO2N) (PR SRD 100D)
; References: 47,48
MID 516 51601 51601 51601 51604 51605 0
;
; Material: NIOBIUM NITRIDE (NBN)
; References: 20,47,48
MID 517 51701 51701 51701 51704 51705 0
;
; Material: NIOBIUM NITRIDE (NB2N)
; References: 20,47,48
MID 518 51801 51801 51801 51804 51805 0
;
; Material: PLUTONIUM NITRIDE (PUN)
; References: 27,48,53
MID 519 51901 51901 51901 51904 51905 0
;
; Material: SILICON NITRIDE (SI3N4) (85 PC DENSE)
; References: 20,27,47,48
MID 520 52001 52001 52001 52004 52005 0
;
; Material: SILICON NITRIDE (SI3N4) (70 PC DENSE)
; References: 20,27,47,48
MID 521 52101 52101 52101 52104 52105 0
;
; Material: TANTALUM NITRIDE (TAN)
; References: 20,27,48
MID 522 52201 52201 52201 52204 52205 0
;
; Material: TANTALUM NITRIDE (TA2N)
; References: 20,27,48
MID 523 52301 52301 52301 52304 52305 0
;
; Material: TITANIUM NITRIDE (TIN) (HP, 70-90 DENS)
; References: 20,27,47,48
MID 524 52401 52401 52401 52404 52405 0
;
; Material: URANIUM NITRIDE (UN) (HP, 95-98 DENSE)
; References: 20,27,48,PWAC481-65
MID 525 52501 52501 52501 52504 52505 0
;
; Material: VANADIUM NITRIDE (VN) (PR, STRD, 100 D)
; References: 20,27,47,48
MID 526 52601 52601 52601 52604 52605 0
;
; Material: ZIRCONIUM NITRIDE (ZRN) (PR SR 88-90 D)
; References: 20,27,47,48
MID 527 52701 52701 52701 52704 52705 0
;
; Material: ZIRCONIUM NITRIDE (ZRN) (PR SR 93 D)
; References: 20,27,47,48
MID 528 52801 52801 52801 52804 52805 0
;
; Material: BERYLLIUM CARBIDE (BE2C) (HP OR SNT)
; References: 14,20,28,47
MID 529 52901 52901 52901 52904 52905 52906
Main Index
634 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: BORON CARBIDE (B4C) (DENSE)
; References: 20,27,48
MID 530 53001 53001 53001 53004 53005 0
;
; Material: BORON CARBIDE (B4C) (POROUS)
; References: 20,27,48
MID 531 53101 53101 53101 53104 53105 0
;
; Material: HAFNIUM CARBIDE (HFC)
; References: 20,27,48,54
MID 532 53201 53201 53201 53204 53205 0
;
; Material: MOLYBDENUM CARBIDE (MO2C)
; References: 20,27,48
MID 533 53301 53301 53301 53304 53305 0
;
; Material: NIOBIUM CARBIDE (NBC)
; References: 20,27,48,54
MID 534 53401 53401 53401 53404 53405 0
;
; Material: PLUTONIUM CARBIDE (PUC) (ARCM OR CAST)
; References: 20,48,53,54
MID 535 53501 53501 53501 53504 53505 0
;
; Material: SILICON CARBIDE (SIC) (SINGLE XTAL)
; References: 20,27,32,47
MID 536 53601 53601 53601 53604 53605 0
;
; Material: SILICON CARBIDE (SIC) (SINGLE XTAL)
; References: 20,32,47,48
MID 537 53701 53701 53701 53704 53705 0
;
; Material: SILICON CARBIDE (SIC) (SLF BND, HE ATM)
; References: 20,27,32,47
MID 538 53801 53801 53801 53804 53805 0
;
; Material: SILICON CARBIDE (SIC) (KT GRADE)
; References: 20,27,32,47,48
MID 539 53901 53901 53901 53904 53905 0
;
; Material: SILICON CARBIDE (SIC) (CARBOFRAX BRICK)
; References: 20,27,32,47
MID 540 54001 54001 54001 54004 54005 0
;
; Material: SILICON CARBIDE (SIC) (FRIT BND BRICK)
; References: 20,27,32,47
MID 541 54101 54101 54101 54104 54105 0
;
; Material: SILICON CARBIDE (SIC) (REXTAL, 80-100D)
; References: 20,27,32,47,48
MID 542 54201 54201 54201 54204 54205 0
;
; Material: SILICON CARBIDE (SIC) (REXTAL, 65-70D)
; References: 1,20,27,32,47
MID 543 54301 54301 54301 54304 54305 0
;
; Material: SILICON CARBIDE (SIC) (BRICK AL2O3 1.7)
; References: 20,27,32,47
MID 544 54401 54401 54401 54404 54405 0
;
; Material: SILICON CARBIDE (SIC) (REFRACTORY D-30)
; References: 20,27,32,47
MID 545 54501 54501 54501 54504 54505 0
;
; Material: SILICON CARBIDE (SIC) (NITRIDE BONDED)
; References: 20,32,47,48
MID 546 54601 54601 54601 54604 54605 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 635
Materials References, Classification, Quality Code and Index
;
; Material: SILICON CARBIDE (SIC) (FOAM, IN VACUUM)
; References: 20,32,47
MID 547 54701 54701 54701 54704 54705 0
;
; Material: SILICON CARBIDE (SIC) (POWDER, IN AIR)
; References: 20,32,47
MID 548 54801 54801 54801 54804 54805 0
;
; Material: SILICON CARBIDE (SIC) (POWDER, IN HE)
; References: 20,32,47
MID 549 54901 54901 54901 54904 54905 0
;
; Material: TANTALUM CARBIDE (TAC)
; References: 20,27,48,54
MID 550 55001 55001 55001 55004 55005 0
;
; Material: THORIUM CARBIDE (THC) (80 PC DENSE)
; References: 20,27,48,54
MID 551 55101 55101 55101 55104 55105 0
;
; Material: THORIUM CARBIDE (THC2) (69 PC DENSE)
; References: 20,27,48,54
MID 552 55201 55201 55201 55204 55205 0
;
; Material: TITANIUM CARBIDE (TIC) (96 PC DENSE)
; References: 20,27,47,48,54
MID 553 55301 55301 55301 55304 55305 0
;
; Material: TITANIUM CARBIDE (TIC) (93 PC DENSE)
; References: 20,27,47,48,54
MID 554 55401 55401 55401 55404 55405 0
;
; Material: TUNGSTEN CARBIDE (WC)
; References: 20,27,47,48,54
MID 555 55501 55501 55501 55504 55505 0
;
; Material: URANIUM CARBIDE (UC) (ARCM OR CAST,99D)
; References: 20,48,53,54
MID 556 55601 55601 55601 55604 55605 0
;
; Material: URANIUM CARBIDE (UC) (SINTERED, 90D)
; References: 20,48,53,54
MID 557 55701 55701 55701 55704 55705 0
;
; Material: URANIUM CARBIDE (UC) (AVG, VAR. TYPES)
; References: 20,48,53,54
MID 558 55801 55801 55801 55804 55805 0
;
; Material: URANIUM CARBIDE (UC2)
; References: 20,27,48,54
MID 559 55901 55901 55901 55904 55905 0
;
; Material: VANADIUM CARBIDE (VC)
; References: 20,27,47,48,54
MID 560 56001 56001 56001 56004 56005 0
;
; Material: ZIRCONIUM CARBIDE (ZRC) (HP OR SNT,94D)
; References: 20,27,48,54
MID 561 56101 56101 56101 56104 56105 0
;
; Material: BARIUM BORIDE (BAB6)
; References: 27,48
MID 562 56201 56201 56201 56204 56205 0
;
; Material: BORON SILICIDE (B4SI)
; References: 27,48
MID 563 56301 56301 56301 56304 56305 0
Main Index
636 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: CALCIUM BORIDE (CAB6)
; References: 27,48
MID 564 56401 56401 56401 56404 56405 0
;
; Material: HAFNIUM BORIDE (HFB2)
; References: 20,27,48
MID 565 56501 56501 56501 56504 56505 0
;
; Material: NIOBIUM BORIDE (NBB2) (PRESSED, SNTRD)
; References: 20,27,48
MID 566 56601 56601 56601 56604 56605 0
;
; Material: YTTRIUM BORIDE (YB6) (98.4 PC DENSE)
; References: 48
MID 567 56701 56701 56701 56704 56705 0
;
; Material: LANTHANUM BORIDE (LAB6) (99.5 PC DENSE)
; References: 48
MID 568 56801 56801 56801 56804 56805 0
;
; Material: CERIUM BORIDE (CEB6) (99.0 PC DENSE)
; References: 48
MID 569 56901 56901 56901 56904 56905 0
;
; Material: PRASEODYMIUM BORIDE (PRB6) (95 PC DENS)
; References: 48
MID 570 57001 57001 57001 57004 57005 0
;
; Material: NEODYMIUM BORIDE (NDB6) (97.3 PC DENSE)
; References: 48
MID 571 57101 57101 57101 57104 57105 0
;
; Material: SAMARIUM BORIDE (SMB6) (96.8 PC DENSE)
; References: 48
MID 572 57201 57201 57201 57204 57205 0
;
; Material: EUROPIUM BORIDE (EUB6) (93.0 PC DENSE)
; References: 48
MID 573 57301 57301 57301 57304 57305 0
;
; Material: GADOLINIUM BORIDE (GDB6) (95.6 PC DENS)
; References: 48
MID 574 57401 57401 57401 57404 57405 0
;
; Material: TERBIUM BORIDE (TBB6) (94.3 PC DENSE)
; References: 48
MID 575 57501 57501 57501 57504 57505 0
;
; Material: YTTERBIUM BORIDE (YBB6) (90.6 PC DENS)
; References: 48
MID 576 57601 57601 57601 57604 57605 0
;
; Material: TANTALUM BORIDE (TAB) (PSD, SNTR, 85D)
; References: 20,27,47,48
MID 577 57701 57701 57701 57704 57705 0
;
; Material: TANTALUM BORIDE (TAB2)
; References: 20,27,47,48
MID 578 57801 57801 57801 57804 57805 0
;
; Material: THORIUM BORIDE (THB4)
; References: 20,27,48
MID 579 57901 57901 57901 57904 57905 0
;
; Material: THORIUM BORIDE (THB6)
; References: 20,27,48
MID 580 58001 58001 58001 58004 58005 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 637
Materials References, Classification, Quality Code and Index
;
; Material: TITANIUM BORIDE (TIB2) (HP, 95 PC DENS)
; References: 20,27,47,48
MID 581 58101 58101 58101 58104 58105 0
;
; Material: TUNGSTEN BORIDE (WB)
; References: 20,27,47,48
MID 582 58201 58201 58201 58204 58205 0
;
; Material: URANIUM BORIDE (UB4)
; References: 20,48
MID 583 58301 58301 58301 58304 58305 0
;
; Material: VANADIUM BORIDE (VB2)
; References: 20,27,48
MID 584 58401 58401 58401 58404 58405 0
;
; Material: ZIRCONIUM BORIDE (ZRB2) (HP, 97 PC DEN)
; References: 20,27,47,48
MID 585 58501 58501 58501 58504 58505 0
;
; Material: MOLYBDENUM BERYLLIDE (MOBE12)
; References: 20,48
MID 586 58601 58601 58601 58604 58605 0
;
; Material: NIOBIUM BERYLLIDE (NBBE12) (HP, 93-97D)
; References: 20,48
MID 587 58701 58701 58701 58704 58705 0
;
; Material: NIOBIUM BERYLLIDE (NB2BE17)
; References: 20,48
MID 588 58801 58801 58801 58804 58805 0
;
; Material: TANTALUM BERYLLIDE (TABE12) (HP)
; References: 20,48
MID 589 58901 58901 58901 58904 58905 58906
;
; Material: TANTALUM BERYLLIDE (TA2BE17)
; References: 20,48
MID 590 59001 59001 59001 59004 59005 0
;
; Material: TITANIUM BERYLLIDE (TIBE12) (HP, 95D)
; References: 20,48
MID 591 59101 59101 59101 59104 59105 0
;
; Material: URANIUM BERYLLIDE (UBE13) (SNTRD, 61D)
; References: 20,48
MID 592 59201 59201 59201 59204 59205 0
;
; Material: VANADIUM BERYLLIDE (VBE12) (85 PC DENS)
; References: 20,48
MID 593 59301 59301 59301 59304 59305 0
;
; Material: ZIRCONIUM BERYLLIDE (ZRBE13)
; References: 20,48
MID 594 59401 59401 59401 59404 59405 0
;
; Material: CERIUM SULFIDE (CES)
; References: 20,48
MID 595 59501 59501 59501 59504 59505 0
;
; Material: CERIUM SULFIDE (CE2S3)
; References: 20,48
MID 596 59601 59601 59601 59604 59605 0
;
; Material: IRON SULFIDE (FES2) (SINGLE CRYSTAL)
; References: 27,47,51
MID 597 59701 59701 59701 59704 59705 0
Main Index
638 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: PLUTONIUM SULFIDE
; References: 53
MID 598 59801 59801 59801 59804 59805 0
;
; Material: SAMARIUM SULFIDE (SMS)
; References: 20,48
MID 599 59901 59901 59901 59904 59905 0
;
; Material: ZINC SULFIDE (ZNS) (CUBIC CRYSTAL)
; References: 1,27,47,48,51
MID 600 60001 60001 60001 60004 60005 60006
;
; Material: PLUTONIUM PHOSPHIDE (PUP) (90 PC DENSE)
; References: 53
MID 601 60101 60101 60101 60104 60105 0
;
; Material: CHROMIUM SILICIDE (CRSI2)
; References: 20,27,48
MID 602 60201 60201 60201 60204 60205 0
;
; Material: COBALT SILICIDE (COS)
; References: 20,48
MID 603 60301 60301 60301 60304 60305 0
;
; Material: MAGNESIUM SILICIDE (MG2SI)
; References: 20,27,48
MID 604 60401 60401 60401 60404 60405 0
;
; Material: MANGANESE SILICIDE (MNSI2)
; References: 20,27,48
MID 605 60501 60501 60501 60504 60505 0
;
; Material: MOLYBDENUM SILICIDE (MOSI2)
; References: 20,27,48
MID 606 60601 60601 60601 60604 60605 0
;
; Material: NIOBIUM SILICIDE (NBSI2)
; References: 20,27
MID 607 60701 60701 60701 60704 60705 0
;
; Material: TANTALUM SILICIDE (TASI2)
; References: 20,27
MID 608 60801 60801 60801 60804 60805 0
;
; Material: TUNGSTEN SILICIDE (WSI2) (HP, 95 DENSE)
; References: 20,27,48
MID 609 60901 60901 60901 60904 60905 0
;
; Material: URANIUM SILICIDE (U3SI)
; References: 20,48
MID 610 61001 61001 61001 61004 61005 0
;
; Material: AMMONIUM BROMIDE (NH4BR) (PRSD 8 KB)
; References: 27,47
MID 611 61101 61101 61101 61104 61105 0
;
; Material: AMMONIUM CHLORIDE (NH4CL) (PRSD 8 KB)
; References: 27,47
MID 612 61201 61201 61201 61204 61205 0
;
; Material: BARIUM FLUORIDE (BAF2) (SINGLE CRYSTAL)
; References: 20,27,51
MID 613 61301 61301 61301 61304 61305 61306
;
; Material: CALCIUM FLUORIDE (CAF2) (SINGLE XTAL)
; References: 1,20,27,47,51
MID 614 61401 61401 61401 61404 61405 61406
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 639
Materials References, Classification, Quality Code and Index
;
; Material: CALCIUM FLUORIDE (CAF2) (MINERAL AGGR)
; References: 1,20,27,47,51
MID 615 61501 61501 61501 61504 61505 61506
;
; Material: LITHIUM FLUORIDE (LIF) (SINGLE CRYSTAL)
; References: 1,20,27,47,51
MID 616 61601 61601 61601 61604 61605 61606
;
; Material: LITHIUM FLUORIDE (LIF 96) (PLASTIC BND)
; References: 1,20,27,47,51
MID 617 61701 61701 61701 61704 61705 61706
;
; Material: MERCURY CHLORIDE (HGCL2) (PRSD 8 KB)
; References: 1,27,47
MID 618 61801 61801 61801 61804 61805 61806
;
; Material: POTASSIUM BROMIDE (KBR) (PRSD 8 KB)
; References: 1,27,47
MID 619 61901 61901 61901 61904 61905 61906
;
; Material: POTASSIUM BROMIDE (KBR) (SINGLE XTAL)
; References: 1,27,47,51
MID 620 62001 62001 62001 62004 62005 62006
;
; Material: POTASSIUM BROMIDE (KBR 90, KCL 10)
; References: 1,27,47,51
MID 621 62101 62101 62101 62104 62105 62106
;
; Material: POTASSIUM BROMIDE (KBR 75, KCL 25)
; References: 1,27,47,51
MID 622 62201 62201 62201 62204 62205 62206
;
; Material: POTASSIUM BROMIDE (KBR 50, KCL 50)
; References: 1,27,47,51
MID 623 62301 62301 62301 62304 62305 62306
;
; Material: POTASSIUM CHLORIDE (KCL 75, KBR 25)
; References: 1,27,47,51
MID 624 62401 62401 62401 62404 62405 62406
;
; Material: POTASSIUM CHLORIDE (KCL 90, KBR 10)
; References: 1,27,47,51
MID 625 62501 62501 62501 62504 62505 62506
;
; Material: POTASSIUM CHLORIDE (KCL) (PRSD 8 KB)
; References: 1,27,47,51
MID 626 62601 62601 62601 62604 62605 62606
;
; Material: POTASSIUM CHLORIDE (KCL) (SYLVITE XTAL)
; References: 1,27,47,51
MID 627 62701 62701 62701 62704 62705 62706
;
; Material: POTASSIUM CHLORIDE (KCL 50, NACL 50)
; References: 1,27,47,51
MID 628 62801 62801 62801 62804 62805 62806
;
; Material: POTASSIUM FLUORIDE (KF) (PRSD 8 KB)
; References: 1,27,47
MID 629 62901 62901 62901 62904 62905 62906
;
; Material: POTASSIUM IODIDE (KI) (PRSD 8 KB)
; References: 1,27,47
MID 630 63001 63001 63001 63004 63005 63006
;
; Material: RUBIDIUM CHLORIDE (RBCL) (PRSD 8 KB)
; References: 1,27,47
MID 631 63101 63101 63101 63104 63105 63106
Main Index
640 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: RUBIDIUM IODIDE (RBI) (PRSD 8 KB)
; References: 1,27,47
MID 632 63201 63201 63201 63204 63205 63206
;
; Material: SILVER CHLORIDE (AGCL) (SINGLE CRYSTAL)
; References: 27,47,51
MID 633 63301 63301 63301 63304 63305 63306
;
; Material: SODIUM BROMIDE (NABR) (PRSD 8 KB)
; References: 1,27,47
MID 634 63401 63401 63401 63404 63405 63406
;
; Material: SODIUM CHLORIDE (NACL) (CLEAR CRYSTAL)
; References: 1,27,47,51,52
MID 635 63501 63501 63501 63504 63505 63506
;
; Material: SODIUM CHLORIDE (NACL) (OPAQUE, IMPURE)
; References: 1,27,47,51,52
MID 636 63601 63601 63601 63604 63605 63606
;
; Material: SODIUM FLUORIDE (NAF) (PRSD 8 KB)
; References: 1,27,47
MID 637 63701 63701 63701 63704 63705 63706
;
; Material: AMMONIA (NH3) (LIQUID UNDER PRESSURE)
; References: 1,27,47
MID 638 63801 63801 63801 63804 63805 0
;
; Material: AMMONIA (NH3) (GAS)
; References: 1,27,47
MID 639 63901 63901 63901 63904 63905 63906
;
; Material: LITHIUM HYDRIDE (LIH) (CAST, VAC VOIDS)
; References: 2020
MID 640 64001 64001 64001 64004 64005 64006
;
; Material: LITHIUM HYDRIDE (LIH) (CAST, GAS VOIDS)
; References: 20
MID 641 64101 64101 64101 64104 64105 64106
;
; Material: METHANE (CH4) (GAS)
; References: 1,27
MID 642 64201 64201 64201 64204 64205 64206
;
; Material: ZIRCONIUM HYDRIDE (ZRH + ZRH2)
; References: 20
MID 643 64301 64301 64301 64304 64305 0
;
; Material: ANTIMONY TELLURIDE (SB2TE3) (POLYXTAL)
; References: 20,27
MID 644 64401 64401 64401 64404 64405 0
;
; Material: ANTIMONY TELLURIDE (SB2TE3) (CPR, N DR)
; References: 20,27
MID 645 64501 64501 64501 64504 64505 0
;
; Material: ARSENIC TELLURIDE (AS2TE3) (V ZONE MLT)
; References: 20
MID 646 64601 64601 64601 64604 64605 0
;
; Material: BISMUTH TELLURIDE (BI2TE3-P) (PLANE DR)
; References: 20,47
MID 647 64701 64701 64701 64704 64705 0
;
; Material: BISMUTH TELLURIDE SULFIDE (BI2TE2S)
; References: 20
MID 648 64801 64801 64801 64804 64805 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 641
Materials References, Classification, Quality Code and Index
;
; Material: INDIUM ANTIMONIDE (INSB) (IMP 0.16)
; References: 20,27
MID 649 64901 64901 64901 64904 64905 64906
;
; Material: INDIUM ANTIMONIDE (INSB) (IMP 0.33-1.2)
; References: 20,27
MID 650 65001 65001 65001 65004 65005 65006
;
; Material: INDIUM ARSENIDE (INAS) (POLYX, IMP 3.0)
; References: 20,27
MID 651 65101 65101 65101 65104 65105 0
;
; Material: INDIUM ARSENIDE (INAS) (PURE, S-DOPED)
; References: 20,27
MID 652 65201 65201 65201 65204 65205 0
;
; Material: INDIUM TELLURIDE (IN2TE3)
; References: 20,27
MID 653 65301 65301 65301 65304 65305 0
;
; Material: LEAD TELLURIDE (PBTE) (SINGLE CRYSTAL)
; References: 20,27
MID 654 65401 65401 65401 65404 65405 0
;
; Material: LEAD TELLURIDE (PBTE) (POLYXTAL)
; References: 20,27
MID 655 65501 65501 65501 65504 65505 0
;
; Material: LITHIUM MANGANESE SELENIDE (97MN.3LI.-)
; References: 20,27
MID 656 65601 65601 65601 65604 65605 0
;
; Material: MANGANESE TELLURIDE (95MNTE.5MNAS)
; References: 20
MID 657 65701 65701 65701 65704 65705 0
;
; Material: MANGANESE TELLURIDE (99MNTE.NATE)
; References: 20
MID 658 65801 65801 65801 65804 65805 0
;
; Material: MOLYBDENUM SELENIDE (MOSE2)
; References: 20
MID 659 65901 65901 65901 65904 65905 0
;
; Material: MOLYBDENUM TELLURIDE (MOTE2)
; References: 20
MID 660 66001 66001 66001 66004 66005 0
;
; Material: SILICON TELLURIDE (SITE)
; References: 20
MID 661 66101 66101 66101 66104 66105 0
;
; Material: TIN TELLURIDE (SNTE 80, AGSBTE2 20)
; References: 20
MID 662 66201 66201 66201 66204 66205 0
;
; Material: TIN TELLURIDE (SNTE 60, AGSBTE2 40)
; References: 20
MID 663 66301 66301 66301 66304 66305 0
;
; Material: SILVER ANTIMONY TELLURIDE (SNTE 25 PC)
; References: 20
MID 664 66401 66401 66401 66404 66405 0
;
; Material: SILVER SELENIDE (AG2SE)
; References: 20,27,47
MID 665 66501 66501 66501 66504 66505 0
Main Index
642 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: TANTALUM ANTIMONIDE (TASB)
; References: 20
MID 666 66601 66601 66601 66604 66605 0
;
; Material: TUNGSTEN SELENIDE (WSE2)
; References: 20,27
MID 667 66701 66701 66701 66704 66705 0
;
; Material: TUNGSTEN TELLURIDE (WTE2)
; References: 20,27
MID 668 66801 66801 66801 66804 66805 0
;
; Material: ZINC ANTIMONIDE (ZNSB)
; References: 20,27,47
MID 669 66901 66901 66901 66904 66905 0
;
; Material: BARIUM NITRATE (BA(NO3)2) (PRSD 8 K8)
; References: 1,27
MID 670 67001 67001 67001 67004 67005 67006
;
; Material: BARIUM SULFATE (BASO4) (CRYSTAL)
; References: 27,51
MID 671 67101 67101 67101 67104 67105 0
;
; Material: CALCIUM CARBONATE (CACO3) (NATURAL)
; References: 1,27,51
MID 672 67201 67201 67201 67204 67205 67206
;
; Material: CALCITE (CACO3) (CRYSTAL) (C AXIS)
; References: 1,27,51
MID 673 67301 67301 67301 67304 67305 67306
;
; Material: CALCITE (CACO3) (CRYSTAL) (A AXIS)
; References: 1,27,51
MID 674 67401 67401 67401 67404 67405 67406
;
; Material: CALCIUM MAGNESIUM CARBONATE (CAMGC2O6)
; References: 1,27,51
MID 675 67501 67501 67501 67504 67505 0
;
; Material: CALCIUM SULFATE DIHYDRATE (CASO4.4H2O)
; References: 1,27,51
MID 676 67601 67601 67601 67604 67605 0
;
; Material: PLASTER, BUILDING (MOLDED, DRY)
; References: 1,27
MID 677 67701 67701 67701 67704 67705 0
;
; Material: GYPSUM (CASO4.4H2O) (ARTIFICIAL)
; References: 1,27
MID 678 67801 67801 67801 67804 67805 0
;
; Material: COPPER SULFATE (CUSO4) (CRYSTAL)
; References: 27
MID 679 67901 67901 67901 67904 67905 0
;
; Material: COPPER SULFATE HYDRATE (CUSO4.5H2O)
; References: 1,27,51
MID 680 68001 68001 68001 68004 68005 0
;
; Material: LITHIUM TETRABORATE (LI2O.2B2O3) (EPOX)
; References: 27
MID 681 68101 68101 68101 68104 68105 0
;
; Material: MAGNESIUM SULFATE (MGSO4) (CRYSTAL)
; References: 1,27
MID 682 68201 68201 68201 68204 68205 68206
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 643
Materials References, Classification, Quality Code and Index
;
; Material: EPSOMITE (MGSO4.7H2O) (CRYSTAL)
; References: 1,27,51
MID 683 68301 68301 68301 68304 68305 0
;
; Material: ALUM (K2SO4.AL2(SO4)3.24H2O) (CRYSTAL)
; References: 1,27
MID 684 68401 68401 68401 68404 68405 0
;
; Material: CHROME ALUM (CR2(SO4)3.K2SO4.24H2O)
; References: 1,27
MID 685 68501 68501 68501 68504 68505 0
;
; Material: POTASSIUM FERROCYANIDE (K4FE(CN)6.3H2O)
; References: 1,27
MID 686 68601 68601 68601 68604 68605 0
;
; Material: POTASSIUM NITRATE (KNO3) (PR 8000 KB)
; References: 1,27
MID 687 68701 68701 68701 68704 68705 68706
;
; Material: SODIUM CHLORATE (NACLO3) (CRYSTAL)
; References: 1,27,51
MID 688 68801 68801 68801 68804 68805 0
;
; Material: STRONTIUM SULFATE (SRSO4) (CRYSTAL)
; References: 1,27,51
MID 689 68901 68901 68901 68904 68905 0
;
; Material: MICA (SINGLE CRYSTAL) (A OR B AXES)
; References: 20,51
MID 690 69001 69001 69001 69004 69005 0
;
; Material: MICA (SINGLE CRYSTAL) (C AXIS)
; References: 20,51
MID 691 69101 69101 69101 69104 69105 0
;
; Material: MICA (SINGLE CRYSTAL) (SYNTHETIC) (98D)
; References: 20
MID 692 69201 69201 69201 69204 69205 0
;
; Material: MICA BRICK (RED OR WHITE) (AVG PROP)
; References: 20
MID 693 69301 69301 69301 69304 69305 0
;
; Material: BRICK, VERMICULITE
; References: 20
MID 694 69401 69401 69401 69404 69405 0
;
; Material: MICA INSULATING POWDER
; References: 20
MID 695 69501 69501 69501 69504 69505 0
;
; Material: VERMICULITE INSULATING POWDER
; References: 20
MID 696 69601 69601 69601 69604 69605 0
;
; Material: PYROPHYLLITE (PARALLEL TO BEDDING)
; References: 27,51
MID 697 69701 69701 69701 69704 69705 0
;
; Material: PYROPHYLLITE (PERPEND. TO BEDDING)
; References: 27,51
MID 698 69801 69801 69801 69804 69805 0
;
; Material: TALC
; References: 20,27,51
MID 699 69901 69901 69901 69904 69905 0
Main Index
644 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: TOURMALINE
; References: 27,51
MID 700 70001 70001 70001 70004 70005 0
;
; Material: GLASS (SEE REF 27, PP E5-E8) (AVG PROP)
; References: 27
MID 701 70101 70101 70101 70104 70105 0
;
; Material: GLASS, BOROSILICATE CROWN
; References: 27,51
MID 702 70201 70201 70201 70204 70205 0
;
; Material: GLASS, PYREX
; References: 2,20,27,51
MID 703 70301 70301 70301 70304 70305 0
;
; Material: GLASS, CERAMIC, PYROCERAM 9606
; References: 20
MID 704 70401 70401 70401 70404 70405 0
;
; Material: GLASS, CERAMIC, PYROCERAM 9608
; References: 20
MID 705 70501 70501 70501 70504 70505 0
;
; Material: DIABASIC GLASS (ARTIFICIAL)
; References: 27,51
MID 706 70601 70601 70601 70604 70605 0
;
; Material: FLINT GLASS
; References: 1,27,46
MID 707 70701 70701 70701 70704 70705 0
;
; Material: FOAMED GLASS (D = 0.144)
; References: 1
MID 708 70801 70801 70801 70804 70805 0
;
; Material: GLASS, LEAD
; References: 20
MID 709 70901 70901 70901 70904 70905 0
;
; Material: GLASS, LIME WINDOW
; References: 20
MID 710 71001 71001 71001 71004 71005 0
;
; Material: GLASS, OBSIDIAN
; References: 27,51
MID 711 71101 71101 71101 71104 71105 0
;
; Material: GLASS, SODA-LIME
; References: 20,27
MID 712 71201 71201 71201 71204 71205 0
;
; Material: GLASS, SODA PLATE
; References: 20,51
MID 713 71301 71301 71301 71304 71305 0
;
; Material: GLASS, VYCOR
; References: 20,27
MID 714 71401 71401 71401 71404 71405 0
;
; Material: ALUMINA BRICK, FUSED (AL2O3 96) (22 P)
; References: 1,20,47
MID 715 71501 71501 71501 71504 71505 71506
;
; Material: ALUMINA BRICK, HIGH (AL2O3 53) (20 P)
; References: 47
MID 716 71601 71601 71601 71604 71605 71606
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 645
Materials References, Classification, Quality Code and Index
;
; Material: ALUMINA BRICK, HIGH (AL2O3 83) (28 P)
; References: 47
MID 717 71701 71701 71701 71704 71705 71706
;
; Material: ALUMINA BRICK, HIGH (AL2O3 87) (22 P)
; References: 20
MID 718 71801 71801 71801 71804 71805 71806
;
; Material: BRICK, MASONRY, MEDIUM
; References: 1,2,27,46
MID 719 71901 71901 71901 71904 71905 0
;
; Material: BRICK, FIRED CARBON
; References: 1,20,27,42,47
MID 720 72001 72001 72001 72004 72005 0
;
; Material: BRICK, CHROME (CR2O3 32)
; References: 1,27,41
MID 721 72101 72101 72101 72104 72105 0
;
; Material: BRICK, CHROME MAGNESITE (SEE REF 47)
; References: 20,47
MID 722 72201 72201 72201 72204 72205 72206
;
; Material: CONCRETE, CINDER
; References: 1,2,20,27,46
MID 723 72301 72301 72301 72304 72305 0
;
; Material: CONCRETE, STONE (1-2-4 MIX)
; References: 1,2,20,27,46
MID 724 72401 72401 72401 72404 72405 0
;
; Material: CONCRETE, 1-4 DRY
; References: 1,2,20,27,46
MID 725 72501 72501 72501 72504 72505 0
;
; Material: CONCRETE, LIGHTWEIGHT
; References: 1,2,20,27,46
MID 726 72601 72601 72601 72604 72605 0
;
; Material: BRICK, DIATOMACEOUS EARTH (ACCR STRATA)
; References: 4
MID 727 72701 72701 72701 72704 72705 0
;
; Material: BRICK, DIATOMACEOUS EARTH (PRLL STRATA)
; References: 4
MID 728 72801 72801 72801 72804 72805 0
;
; Material: BRICK, DIATOMACEOUS EARTH (MOLDED, FRD)
; References: 4
MID 729 72901 72901 72901 72904 72905 0
;
; Material: BRICK, DIATOMACEOUS EARTH (HIGH BURN)
; References: 4
MID 730 73001 73001 73001 73004 73005 0
;
; Material: BRICK, DIATOMACEOUS EARTH (USE TO 850C)
; References: 4
MID 731 73101 73101 73101 73104 73105 0
;
; Material: BRICK, DIATOMACEOUS EARTH (USE TO 1100)
; References: 4
MID 732 73201 73201 73201 73204 73205 0
;
; Material: BRICK, STABILIZED DOLOMITE (22 P)
; References: 1,47
MID 733 73301 73301 73301 73304 73305 0
Main Index
646 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: BRICK, EGYPTIAN FIRE (SIO2 64-71)
; References: 20
MID 734 73401 73401 73401 73404 73405 0
;
; Material: BRICK, NORMAL FIRECLAY (22 P)
; References: 47
MID 735 73501 73501 73501 73504 73505 0
;;
; Material: BRICK, MISSOURI FIRECLAY
; References: 1,47
MID 736 73601 73601 73601 73604 73605 0
;
; Material: BRICK, SILICEOUS FIRECLAY (23 P)
; References: 47
MID 737 73701 73701 73701 73704 73705 0
;
; Material: BRICK, FORSTERITE (MGO 58 SIO2 38)(20P)
; References: 20,47
MID 738 73801 73801 73801 73804 73805 73806
;
; Material: BRICK, KAOLIN INSULATING (D = 0.43)
; References: 1,20
MID 739 73901 73901 73901 73904 73905 0
;
; Material: BRICK, KAOLIN INSULATING (D = 0.30)
; References: 1,20
MID 740 74001 74001 74001 74004 74005 0
;
; Material: BRICK, MAGNESITE SPALL RES (MGO 89)
; References: 1,20,27,47,48
MID 741 74101 74101 74101 74104 74105 74106
;
; Material: BRICK, MAGNESITE (MGO 87)
; References: 1,20,27,47,48
MID 742 74201 74201 74201 74204 74205 74206
;
; Material: BRICK, MAGNESITE A (MGO 90) (14.5 P)
; References: 1,20,27,47,48
MID 743 74301 74301 74301 74304 74305 74306
;
; Material: BRICK, MAGNESITE B 93) (22.6 P)
; References: 1,20,27,47,48
MID 744 74401 74401 74401 74404 74405 74406
;
; Material: BRICK, MAGNESITE C 86) (17.8 P)
; References: 1,20,27,47,48
MID 745 74501 74501 74501 74504 74505 74506
;
; Material: BERYLLIUM OXIDE PORCELAIN 4811
; References: 20
MID 746 74601 74601 74601 74604 74605 0
;
; Material: ALUMINA PORCELAIN, HIGH
; References: 20
MID 747 74701 74701 74701 74704 74705 0
;
; Material: PORCELAIN, HIGH ZIRCON
; References: 20
MID 748 74801 74801 74801 74804 74805 0
;
; Material: MAGNESIUM TITANATE PORCELAIN
; References: 20,48
MID 749 74901 74901 74901 74904 74905 0
;
; Material: PORCELAIN 576
; References: 20
MID 750 75001 75001 75001 75004 75005 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 647
Materials References, Classification, Quality Code and Index
;
; Material: PORCELAIN, ORDINARY
; References: 1,20
MID 751 75101 75101 75101 75104 75105 0
;
; Material: VERMICULITE, EXPANDED (D = 0.19-0.25)
; References: 20
MID 752 75201 75201 75201 75204 75205 0
;
; Material: VERMICULITE, EXPANDED (D = 0.3)
; References: 20
MID 753 75301 75301 75301 75304 75305 0
;
; Material: BRICK, HARD FIRED SILICA (SIO2 94-95)
; References: 20
MID 754 75401 75401 75401 75404 75405 75406
;
; Material: BRICK, SILICEOUS (SIO2 89 AL2O3 9)(25P)
; References: 47
MID 755 75501 75501 75501 75504 75505 75506
;
; Material: BRICK, SILLIMANITE (22 PC POROSITY)
; References: 20
MID 756 75601 75601 75601 75604 75605 0
;
; Material: ALUMINUM OXIDE + CR (AL2O3 23, CR 77)
; References: 20,48
MID 757 75701 75701 75701 75704 75705 0
;
; Material: ALUMINUM OXIDE + CR (AL2O3 70, CR 30)
; References: 20,48
MID 758 75801 75801 75801 75804 75805 0
;
; Material: BERYLLIUM OXIDE + BE (BEO, BE 3-12)
; References: 20
MID 759 75901 75901 75901 75904 75905 0
;
; Material: BERYLLIUM OXIDE + BE + MO (BE 7, MO 7)
; References: 20
MID 760 76001 76001 76001 76004 76005 0
;
; Material: BERYLLIUM OXIDE + BE + SI
; References: 20
MID 761 76101 76101 76101 76104 76105 0
;
; Material: BERYLLIUM + BEO (BE, BEO 0.6-1.7)
; References: 20
MID 762 76201 76201 76201 76204 76205 76206
;
; Material: CHROMIUM CARBIDE + NI (CR(X)C(Y), NI)
; References: 48
MID 763 76301 76301 76301 76304 76305 0
;
; Material: SILICON CARBIDE + SI (SIC 76, SI 24)
; References: 20
MID 764 76401 76401 76401 76404 76405 0
;
; Material: STRONTIUM TITANATE + CO (CO 10)
; References: 20
MID 765 76501 76501 76501 76504 76505 0
;
; Material: STRONTIUM TITANATE + CO (CO 20)
; References: 20
MID 766 76601 76601 76601 76604 76605 0
;
; Material: STRONTIUM TITANATE + CO (CO 30)
; References: 20
MID 767 76701 76701 76701 76704 76705 0
Main Index
648 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: STRONTIUM TITANATE + CO (CO 40)
; References: 20
MID 768 76801 76801 76801 76804 76805 0
;
; Material: TITANIUM CARBIDE + CO (TIC 80, CO 20)
; References: 20
MID 769 76901 76901 76901 76904 76905 0
;
; Material: TITANIUM CARBIDE + CO (CO18, NBC,TAC15)
; References: 20
MID 770 77001 77001 77001 77004 77005 0
;
; Material: TITANIUM CARBIDE + NBC + NI
; References: 20
MID 771 77101 77101 77101 77104 77105 0
;
; Material: TITANIUM CARBIDE CERMET K162B
; References: 49
MID 772 77201 77201 77201 77204 77205 0
;
; Material: TITANIUM CARBIDE CERMET K138A
; References: 49
MID 773 77301 77301 77301 77304 77305 0
;
; Material: TITANIUM CARBIDE CERMET K151A
; References: 49
MID 774 77401 77401 77401 77404 77405 0
;
; Material: TITANIUM CARBIDE CERMET K163B1
; References: 49
MID 775 77501 77501 77501 77504 77505 0
;
; Material: TITANIUM CARBIDE CERMET K164B
; References: 49
MID 776 77601 77601 77601 77604 77605 0
;
; Material: TITANIUM CARBIDE CERMET K165
; References: 49
MID 777 77701 77701 77701 77704 77705 0
;
; Material: TITANIUM CARBIDE CERMET K161B
; References: 20
MID 778 77801 77801 77801 77804 77805 0
;
; Material: TITANIUM CARBIDE + NI OR CO (AVG PROP)
; References: 48
MID 779 77901 77901 77901 77904 77905 0
;
; Material: STEEL, TOOL, TUNGSTEN CARBIDE CA4
; References: 20
MID 780 78001 78001 78001 78004 78005 0
;
; Material: STEEL, TOOL, TUNGSTEN CARBIDE CA2
; References: 20
MID 781 78101 78101 78101 78104 78105 0
;
; Material: TUNGSTEN CARBIDE CERMET K6 AND K96
; References: 20,49
MID 782 78201 78201 78201 78204 78205 0
;
; Material: TANTALUM CARBIDE + WC CERMET K601
; References: 49
MID 783 78301 78301 78301 78304 78305 0
;
; Material: TUNGSTEN CARBIDE CERMET K94 AND K1
; References: 49
MID 784 78401 78401 78401 78404 78405 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 649
Materials References, Classification, Quality Code and Index
;
; Material: TUNGSTEN CARBIDE CERMET K92
; References: 49
MID 785 78501 78501 78501 78504 78505 0
;
; Material: TUNGSTEN CARBIDE CERMET K701
; References: 49
MID 786 78601 78601 78601 78604 78605 0
;
; Material: TUNGSTEN CARBIDE CERMET K801 (WC + NI)
; References: 49
MID 787 78701 78701 78701 78704 78705 0
;
; Material: TUNGSTEN CARBIDE CERMET CARBOLOY 999
; References: 50
MID 788 78801 78801 78801 78804 78805 0
;
; Material: TUNGSTEN CARBIDE CERMET CARBOLOY 905
; References: 50
MID 789 78901 78901 78901 78904 78905 0
;
; Material: TUNGSTEN CARBIDE CERMET CARBOLOY 883
; References: 50
MID 790 79001 79001 79001 79004 79005 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K2S
; References: 20,49
MID 791 79101 79101 79101 79104 79105 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K86, K7H, K3H
; References: 49
MID 792 79201 79201 79201 79204 79205 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K84
; References: 49
MID 793 79301 79301 79301 79304 79305 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K81
; References: 49
MID 794 79401 79401 79401 79404 79405 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K5H
; References: 49
MID 795 79501 79501 79501 79504 79505 0
;
; Material: TUNGSTEN TITANIUM CARBIDE KM
; References: 49
MID 796 79601 79601 79601 79604 79605 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K4H
; References: 49
MID 797 79701 79701 79701 79704 79705 0
;
; Material: TUNGSTEN TITANIUM CARBIDE K21
; References: 49
MID 798 79801 79801 79801 79804 79805 0
;
; Material: URANIUM OXIDE + CR (UO2 8O VOL) (97 D)
; References: 20
MID 799 79901 79901 79901 79904 79905 0
;
; Material: URANIUM OXIDE + MO (UO2 8O VOL) (94 D)
; References: 20
MID 800 80001 80001 80001 80004 80005 0
;
; Material: URANIUM OXIDE + MO (UO2 8O VOL) (91 D)
; References: 20
MID 801 80101 80101 80101 80104 80105 0
Main Index
650 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: URANIUM OXIDE + MO (UO2 70 VOL) (92 D)
; References: 20
MID 802 80201 80201 80201 80204 80205 0
;
; Material: URANIUM OXIDE + NB (UO2 80 VOL)
; References: 20
MID 803 80301 80301 80301 80304 80305 0
;
; Material: URANIUM OXIDE + ST STEEL (UO2 70 VOL)
; References: 20
MID 804 80401 80401 80401 80404 80405 0
;
; Material: URANIUM OXIDE + ST STEEL (UO2 80 VOL)
; References: 20
MID 805 80501 80501 80501 80504 80505 0
;
; Material: URANIUM OXIDE + ZR (UO2 43,ZR 57)(59 P)
; References: 20
MID 806 80601 80601 80601 80604 80605 0
;
; Material: URANIUM OXIDE + ZR (UO2 80,ZR 20)
; References: 20
MID 807 80701 80701 80701 80704 80705 0
;
; Material: ZIRCONIUM OXIDE + TI CERMET ZT-15-M
; References: 20
MID 808 80801 80801 80801 80804 80805 0
;
; Material: ZIRCONIUM OXIDE (Y2O3 12, ZR 8) (97 D)
; References: 20
MID 809 80901 80901 80901 80904 80905 0
;
; Material: BOROLITE 101 CERMET (ZRB2 93-96, B 4-7)
; References: 47,48
MID 810 81001 81001 81001 81004 81005 0
;
; Material: BORIDE Z CERMET (ZRB2 81-87, MOSI2 13)
; References: 47,48
MID 811 81101 81101 81101 81104 81105 0
;
; Material: AIR
; References: 1,2,46
MID 812 81201 81201 81201 81204 81205 81206
;
; Material: GRANITE (LOW K)
; References: 1,2,27,46,51
MID 813 81301 81301 81301 81304 81305 0
;
; Material: GRANITE (HIGH K)
; References: 1,2,27,46,51
MID 814 81401 81401 81401 81404 81405 0
;
; Material: GRANITE (AV PROP) (SEE REF 51)
; References: 1,2,27,46,51
MID 815 81501 81501 81501 81504 81505 0
;
; Material: LIMESTONE (DENSE, DRY)
; References: 1,2,27,46,51
MID 816 81601 81601 81601 81604 81605 0
;
; Material: LIMESTONE (H2O 15.3)
; References: 1,2,27,46,51
MID 817 81701 81701 81701 81704 81705 0
;
; Material: CHALK (AV PROP)
; References: 1,46
MID 818 81801 81801 81801 81804 81805 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 651
Materials References, Classification, Quality Code and Index
;
; Material: MARBLE DIELECTRIC (XTAL) (CACO3 99.99)
; References: 1,27,51
MID 819 81901 81901 81901 81904 81905 0
;
; Material: MARBLE (AV PROP) (SEE REF 51)
; References: 1,27,51
MID 820 82001 82001 82001 82004 82005 0
;
; Material: ROCK OR STONE (AVERAGE PROPERTIES)
; References: 1,46
MID 821 82101 82101 82101 82104 82105 0
;
; Material: SANDSTONE (HIGH DENSITY)
; References: 2,27,46,51
MID 822 82201 82201 82201 82204 82205 0
;
; Material: SANDSTONE (LOW DENSITY)
; References: 2,27,46,51
MID 823 82301 82301 82301 82304 82305 0
;
; Material: SANDSTONE (AV PROP) (SEE REF 51)
; References: 2,27,46,51
MID 824 82401 82401 82401 82404 82405 0
;
; Material: SHALE (AV PROP) (SEE REF 51)
; References: 51
MID 825 82501 82501 82501 82504 82505 0
;
; Material: SLATE (AV PROP) (SEE REF 51)
; References: 51
MID 826 82601 82601 82601 82604 82605 0
;
; Material: QUARTZ FLOUR, FINE (DRY)
; References: 51
MID 827 82701 82701 82701 82704 82705 0
;
; Material: SOIL, FINE QUARTZ FLOUR (H2O 21 PC)
; References: 51
MID 828 82801 82801 82801 82804 82805 0
;
; Material: QUARTZ SAND (DRY) (AV PROP) (SEE REF)
; References: 51
MID 829 82901 82901 82901 82904 82905 0
;
; Material: QUARTZ SAND (WET) (H2O 4-23) (AV PROP)
; References: 51
MID 830 83001 83001 83001 83004 83005 0
;
; Material: SAND, NORTHWAY (H2O 4-10) (AV PROP)
; References: 51
MID 831 83101 83101 83101 83104 83105 0
;
; Material: QUARTZ POWDER, COARSE (H2O 24)
; References: 51
MID 832 83201 83201 83201 83204 83205 0
;
; Material: SOIL, LOAM (DRY) (AV PROP) (SEE REFS)
; References: 2,51
MID 833 83301 83301 83301 83304 83305 0
;
; Material: SOIL, LOAM (H2O 4-27 PC) (AV, SEE REFS)
; References: 2,51
MID 834 83401 83401 83401 83404 83405 0
;
; Material: SOIL, CLAY (WET)
; References: 51
MID 835 83501 83501 83501 83504 83505 0
Main Index
652 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: SOIL (AV PROPS) (SEE REFS)
; References: 2,46,51
MID 836 83601 83601 83601 83604 83605 0
;
; Material: SOIL, MARS SURFACE (SEE UCRL-50309)
; References:
MID 837 83701 83701 83701 83704 83705 0
;
; Material: SOIL, SANDY DRY
; References: 46
MID 838 83801 83801 83801 83804 83805 0
;
; Material: SOIL, SANDY (H20 8)
; References: 46
MID 839 83901 83901 83901 83904 83905 0
;
; Material: ABS RESIN (LOW K)
; References: 6
MID 840 84001 84001 84001 84004 84005 0
;
; Material: ABS RESIN (HIGH K)
; References: 6
MID 841 84101 84101 84101 84104 84105 0
;
; Material: ACETYL (DELRIN)
; References: 6,38
MID 842 84201 84201 84201 84204 84205 0
;
; Material: ACRYLIC (LUCITE, PLEXIGLASS)
; References: 6,20,38
MID 843 84301 84301 84301 84304 84305 0
;
; Material: ACRYLIC (HIGH K)
; References: 6,38
MID 844 84401 84401 84401 84404 84405 0
;
; Material: ALKYD ISOCYANATE FOAM (DENSITY 0.16)
; References: 20
MID 845 84501 84501 84501 84504 84505 0
;
; Material: ALLYL, CAST RESINS (HIGH HEAT CAPACITY)
; References: 6,38
MID 846 84601 84601 84601 84604 84605 0
;
; Material: ALLYL, CAST RESINS (LOW HEAT CAPACITY)
; References: 6,38
MID 847 84701 84701 84701 84704 84705 0
;
; Material: BUTADIENE-ACRYLONITRILE RUBBER + C
; References: 20
MID 848 84801 84801 84801 84804 84805 0
;
; Material: BUTYL RUBBER
; References: 6,39
MID 849 84901 84901 84901 84904 84905 0
;
; Material: CELLULOSE ACETATE (LOW K)
; References: 6,38
MID 850 85001 85001 85001 85004 85005 0
;
; Material: CELLULOSE ACETATE (HIGH K)
; References: 6,38
MID 851 85101 85101 85101 85104 85105 0
;
; Material: CELLULOSE ACETATE BUTYRATE (LOW K)
; References: 6,38
MID 852 85201 85201 85201 85204 85205 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 653
Materials References, Classification, Quality Code and Index
;
; Material: CELLULOSE ACETATE BUTYRATE (HIGH K)
; References: 6,38
MID 853 85301 85301 85301 85304 85305 0
;
; Material: CELLULOSE NITRATE (PYROXYLIN)
; References: 6,38
MID 854 85401 85401 85401 85404 85405 0
;
; Material: CELLULOSE PROPRIONATE (LOW K)
; References: 6,38
MID 855 85501 85501 85501 85504 85505 0
;
; Material: CELLULOSE PROPRIONATE (HIGH K)
; References: 6,38
MID 856 85601 85601 85601 85604 85605 0
;
; Material: CELLULOSE TRIACETATE
; References: 38
MID 857 85701 85701 85701 85704 85705 0
;
; Material: DIALLYL PHTHALATE (DAPON)
; References: 35
MID 858 85801 85801 85801 85804 85805 0
;
; Material: EPOXY, DER 332 (C), HYSOL 6000-OP (K)
; References: 6,20,38
MID 859 85901 85901 85901 85904 85905 0
;
; Material: EPOXY, GLASS FIBER FILLED (MOLDED)
; References: 20,38
MID 860 86001 86001 86001 86004 86005 0
;
; Material: EPOXY, SILICA FILLED, CAST
; References: 38
MID 861 86101 86101 86101 86104 86105 0
;
; Material: EPOXY, UNFILLED, CAST
; References: 38
MID 862 86201 86201 86201 86204 86205 0
;
; Material: ETHYL CELLULOSE (WIDE RANGE OF C, K)
; References: 6,38
MID 863 86301 86301 86301 86304 86305 0
;
; Material: ETHYL VINYL ACETATE
; References: 38
MID 864 86401 86401 86401 86404 86405 0
;
; Material: FLUOROCARBONS, CFE AND CTFE
; References: 6,38
MID 865 86501 86501 86501 86504 86505 0
;
; Material: FLUOROCARBONS, FEP
; References: 6,38
MID 866 86601 86601 86601 86604 86605 0
;
; Material: FLUOROCARBONS, TFE (TEFLON)
; References: 1,6,20,38
MID 867 86701 86701 86701 86704 86705 0
;
; Material: TEFLON, REINFORCED
; References: 20
MID 868 86801 86801 86801 86804 86805 0
;
; Material: MELAMINE (LOW DENS, LOW K)
; References: 6,38
MID 869 86901 86901 86901 86904 86905 0
Main Index
654 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: MELAMINE (HIGH DENS, HIGH K)
; References: 6,38
MID 870 87001 87001 87001 87004 87005 0
;
; Material: MELAMINE, ALPHA CELLULOSE FILLED
; References: 38
MID 871 87101 87101 87101 87104 87105 0
;
; Material: MELAMINE, ASBESTOS FILLED (MST 95-205)
; References: 38
MID 872 87201 87201 87201 87204 87205 0
;
; Material: MELAMINE, CELLULOSE FILLED (MST 95-205)
; References: 38
MID 873 87301 87301 87301 87304 87305 0
;
; Material: MELAMINE, GLASS FIBER FILLED (MST 205)
; References: 6,38
MID 874 87401 87401 87401 87404 87405 0
;
; Material: MELAMINE, FABRIC OR FLOCK FILLED
; References: 6,38
MID 875 87501 87501 87501 87504 87505 0
;
; Material: METHYL METHACRYLATE
; References: 1,38
MID 876 87601 87601 87601 87604 87605 0
;
; Material: NEOPRENE RUBBER
; References: 6,38,39
MID 877 87701 87701 87701 87704 87705 0
;
; Material: NITRILE RUBBER
; References: 6,39
MID 878 87801 87801 87801 87804 87805 0
;
; Material: NYLON 6, 11, 66, 610 (POLYCAPROLACTAM)
; References: 1,6,38
MID 879 87901 87901 87901 87904 87905 0
;
; Material: NYLON, GLASS FILLED
; References:
MID 880 88001 88001 88001 88004 88005 0
;
; Material: PHENOL-FORMALDEHYDE + PHENOL-FURFURAL
; References: 20
MID 881 88101 88101 88101 88104 88105 0
;
; Material: PHENOLIC, CAST, NO FILLER
; References: 6,38
MID 882 88201 88201 88201 88204 88205 0
;
; Material: PHENOLIC, CAST, ASBESTOS FILLER
; References: 6,38
MID 883 88301 88301 88301 88304 88305 0
;
; Material: PHENOLIC, MOLDED (LOW DENSITY, K)
; References: 6
MID 884 88401 88401 88401 88404 88405 0
;
; Material: PHENOLIC, MOLDED (HIGH DENSITY, K)
; References: 6
MID 885 88501 88501 88501 88504 88505 0
;
; Material: PHENOLIC RESIN, PRESSED, TYPES 40, 50
; References: 20
MID 886 88601 88601 88601 88604 88605 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 655
Materials References, Classification, Quality Code and Index
;
; Material: PHENOXY
; References: 6,38
MID 887 88701 88701 88701 88704 88705 0
;
; Material: PLASTIC LAMINATE, VARIOUS TYPES
; References: 6,20
MID 888 88801 88801 88801 88804 88805 0
;
; Material: POLYALLOMER
; References: 6,38
MID 889 88901 88901 88901 88904 88905 0
;
; Material: POLYCARBONATE, VARIOUS FILLERS
; References: 6,38
MID 890 89001 89001 89001 89004 89005 0
;
; Material: POLYESTER, GLASS FIBER REINFORCED, TAC
; References: 20
MID 891 89101 89101 89101 89104 89105 0
;
; Material: POLYETHYLENE, LOW DENSITY
; References: 6,38
MID 892 89201 89201 89201 89204 89205 0
;
; Material: POLYETHYLENE, MEDIUM DENSITY
; References: 6,38
MID 893 89301 89301 89301 89304 89305 0
;
; Material: POLYETHYLENE, HIGH DENSITY
; References: 6,38
MID 894 89401 89401 89401 89404 89405 0
;
; Material: POLYIMIDE, H-FILM, KAPTON
; References: 6,40
MID 895 89501 89501 89501 89504 89505 0
;
; Material: POLYPROPYLENE, MOPLIN
; References: 6,38
MID 896 89601 89601 89601 89604 89605 0
;
; Material: POLYPROPYLENE, COPOLYMER
; References: 6,38
MID 897 89701 89701 89701 89704 89705 0
;
; Material: POLYPROPYLENE, FILLED
; References: 6
MID 898 89801 89801 89801 89804 89805 0
;
; Material: POLYSTYRENE, FOAMED-IN-PLACE, RIGID
; References: 6
MID 899 89901 89901 89901 89904 89905 0
;
; Material: POLYSTYRENE, GENERAL PURPOSE
; References: 6,20,38
MID 900 90001 90001 90001 90004 90005 0
;
; Material: POLYSTYRENE, MODIFIED
; References: 6
MID 901 90101 90101 90101 90104 90105 0
;
; Material: POLYSTYRENE, PREFOAMED, RIGID, DOW Q103
; References: 6,20
MID 902 90201 90201 90201 90204 90205 0
;
; Material: POLYSTYRENE FOAM (D = 0.038) (1 ATM)
; References: 1
MID 903 90301 90301 90301 90304 90305 0
Main Index
656 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: POLYSTYRENE FOAM (D = 0.046) (1 ATM)
; References: 1
MID 904 90401 90401 90401 90404 90405 0
;
; Material: POLYSTYRENE FOAM (D = 0.046) (VACUUM)
; References: 1
MID 905 90501 90501 90501 90504 90505 0
;
; Material: POLYSULFONE
; References: 5,6,38
MID 906 90601 90601 90601 90604 90605 0
;
; Material: POLYURETHANE FOAM, FLEXIBLE
; References: 6,20,38
MID 907 90701 90701 90701 90704 90705 0
;
; Material: POLYURETHANE FOAMED-IN-PLACE, RIGID
; References: 6,20
MID 908 90801 90801 90801 90804 90805 0
;
; Material: POLYURETHANE RUBBER L-100
; References: 6,38
MID 909 90901 90901 90901 90904 90905 0
;
; Material: POLYVINYL ALCOHOL
; References: 6
MID 910 91001 91001 91001 91004 91005 0
;
; Material: POLYVINYL BUTYRAL
; References: 6,38
MID 911 91101 91101 91101 91104 91105 0
;
; Material: POLYVINYL CARBAZOLE
; References: 20
MID 912 91201 91201 91201 91204 91205 0
;
; Material: POLYVINYL CHLORIDE, FLEXIBLE
; References: 6,38,20
MID 913 91301 91301 91301 91304 91305 0
;
; Material: POLYVINYL CHLORIDE, RIGID
; References: 6,38,20
MID 914 91401 91401 91401 91404 91405 0
;
; Material: POLYVINYL CHLORIDE ACYTATE, FLEXIBLE
; References: 38
MID 915 91501 91501 91501 91504 91505 0
;
; Material: POLYVINYL CHLORIDE ACYTATE, RIGID
; References: 38
MID 916 91601 91601 91601 91604 91605 0
;
; Material: POLYVINYLIDENE CHLORIDE FILM
; References: 6,38
MID 917 91701 91701 91701 91704 91705 0
;
; Material: POLYVINYLIDENE CHLORIDE
; References: 6,38
MID 918 91801 91801 91801 91804 91805 0
;
; Material: POLYVINYLIDENE FLUORIDE (KYNAR)
; References: 5,38
MID 919 91901 91901 91901 91904 91905 0
;
; Material: POLYVINYL TPX-R
; References: 5,38
MID 920 92001 92001 92001 92004 92005 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 657
Materials References, Classification, Quality Code and Index
;
; Material: RUBBER, NATURAL
; References: 6
MID 921 92101 92101 92101 92104 92105 0
;
; Material: RUBBER, DIELECTRIC MIX
; References: 6,20
MID 922 92201 92201 92201 92204 92205 0
;
; Material: RUBBER, HIGH K
; References: 6,20
MID 923 92301 92301 92301 92304 92305 0
;
; Material: RUBBER, NATURAL, FOAM
; References: 6,20
MID 924 92401 92401 92401 92404 92405 0
;
; Material: SILICONE FOAM, FLEXIBLE (LRL)
; References: 6,20
MID 925 92501 92501 92501 92504 92505 0
;
; Material: SILICONE FOAM, RIGID, VARIOUS
; References: 6,20
MID 926 92601 92601 92601 92604 92605 0
;
; Material: SILICONE, MOLDED, VARIOUS FILLERS
; References: 6,20,38
MID 927 92701 92701 92701 92704 92705 0
;
; Material: SILICONE RUBBER, LOW K (SEE REF 5)
; References: 5,6,41,44
MID 928 92801 92801 92801 92804 92805 0
;
; Material: SILICONE RUBBER, MEDIUM K (SEE REF 5)
; References: 5,6,41,44
MID 929 92901 92901 92901 92904 92905 0
;
; Material: SILICONE RUBBER, HIGH K (SEE REF 5)
; References: 5,6,41,44
MID 930 93001 93001 93001 93004 93005 0
;
; Material: SILICONE RUBBER, RTV 521 AND 093-009
; References: 5,6,41,44
MID 931 93101 93101 93101 93104 93105 0
;
; Material: RUBBER, BUNA, WITH CARBON BLACK
; References: 6,20,39
MID 932 93201 93201 93201 93204 93205 0
;
; Material: UREA-FORMALDEHYDE, MOLDED
; References: 38
MID 933 93301 93301 93301 93304 93305 0
;
; Material: UREA-FORMALDEHYDE, ALPHA CELLULOSE FLLR
; References: 38
MID 934 93401 93401 93401 93404 93405 0
;
; Material: BARATOL H.E. (TNT 26, BA NITRATE 76)
; References: 8
MID 935 93501 93501 93501 93504 93505 0
;
; Material: COMPOSITION B-3 H.E. (RDX 60, TNT 40)
; References: 8
MID 936 93601 93601 93601 93604 93605 0
;
; Material: COMPOSITION C-4 H.E. (RDX 90, BINDERS)
; References: 8
MID 937 93701 93701 93701 93704 93705 0
Main Index
658 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
;
; Material: DATB H.E. (DIAMINO TRINITROBENZENE)
; References: 8
MID 938 93801 93801 93801 93804 93805 0
;
; Material: LX-O4-1 H.E. (HMX 85, VITON A 15)
; References: 8
MID 939 93901 93901 93901 93904 93905 0
;
; Material: MOCK H.E. RM-04-BG (LX-04-1 MECH MOCK)
; References: 8
MID 940 94001 94001 94001 94004 94005 0
;
; Material: MOCK H.E. 90010 (PBX-9404 MECH MOCK)
; References: 8
MID 941 94101 94101 94101 94104 94105 0
;
; Material: NITROCELLULOSE H.E. (12.7 N)
; References: 8
MID 942 94201 94201 94201 94204 94205 0
;
; Material: PBX-9011 H.E. (HMX 90, ESTANE 10)
; References: 8
MID 943 94301 94301 94301 94304 94305 0
;
; Material: PBX-9404-03 H.E. (HMX 94, NC 3, BIND 3)
; References: 8,44
MID 944 94401 94401 94401 94404 94405 0
;
; Material: PETN H.E.
; References: 8
MID 945 94501 94501 94501 94504 94505 0
;
; Material: TETRYL H.E.
; References: 8
MID 946 94601 94601 94601 94604 94605 0
;
; Material: TNT H.E. (2,4,6-TRINITROTOLUENE) (CAST)
; References: 8
MID 947 94701 94701 94701 94704 94705 0
;
; Material: MOCK H.E. LM-04-0 H4-048-A294-3
; References: 5,8
MID 948 94801 94801 94801 94804 94805 0
;
; Material: MOCK H.E. LM-04-0 H7-048-A522.1
; References: 5,8
MID 949 94901 94901 94901 94904 94905 0
;
; Material: FIBERFAX PAPER (CARBORUNDUM CO.)
; References: 44
MID 950 95001 95001 95001 95004 95005 0
;
; Material: RATTAN
; References: 44
MID 951 95101 95101 95101 95104 95105 0
;
; Material: SNOW, FRESH
; References: 2,27
MID 952 95201 95201 95201 95204 95205 95206
;
; Material: SNOW, PACKED
; References: 27,46
MID 953 95301 95301 95301 95304 95305 95306
;
; Material: WOOD, SPRUCE (WITH GRAIN)
; References: 46
MID 954 95401 95401 95401 95404 95405 0
Main Index
Appendix B: Mid Templates Supplied in Templatebin and Templatetxt 659
Materials References, Classification, Quality Code and Index
;
; Material: WOOD, SPRUCE (ACROSS GRAIN)
; References: 46
MID 955 95501 95501 95501 95504 95505 0
;
; Material: CORK, GROUND
; References: 2,46
MID 956 95601 95601 95601 95604 95605 0
;
; Material: CORK, GROUND, REGRANULATED
; References: 2,46
MID 957 95701 95701 95701 95704 95705 0
;
; Material: WOOD, BALSA (ACROSS GRAIN)
; References: 1,2,27
MID 958 95801 95801 95801 95804 95805 0
;
; Material: WOOD, BALSA (ACROSS GRAIN)
; References: 1,2,27
MID 959 95901 95901 95901 95904 95905 0
;
; Material: WOOD, CYPRESS (ACROSS GRAIN)
; References: 1,27
MID 960 96001 96001 96001 96004 96005 0
;
; Material: WOOD, MAHOGANY (ACROSS GRAIN)
; References: 1,27
MID 961 96101 96101 96101 96104 96105 0
;
; Material: WOOD, MAPLE (ACROSS GRAIN)
; References: 1,2,27
MID 962 96201 96201 96201 96204 96205 0
;
; Material: WOOD, OAK, WHITE, LIVE (ACROSS GRAIN)
; References: 1,2,27
MID 963 96301 96301 96301 96304 96305 0
;
; Material: WOOD, OAK, RED, BLACK (ACROSS GRAIN)
; References: 1,2,27
MID 964 96401 96401 96401 96404 96405 0
;
; Material: WOOD, NORWAY PINE (ACROSS GRAIN)
; References: 1,2,27
MID 965 96501 96501 96501 96504 96505 0
;
; Material: WOOD, OREGON PINE (ACROSS GRAIN)
; References: 1,2,27
MID 966 96601 96601 96601 96604 96605 0
;
; Material: WOOD, VIRGINIA PINE (ACROSS GRAIN)
; References: 1,2,27
MID 967 96701 96701 96701 96704 96705 0
;
; Material: WOOD, NORWAY PINE (ACROSS GRAIN)
; References: 1,2,27
MID 968 96801 96801 96801 96804 96805 0
;
; Material: WOOD, TEAK (ACROSS GRAIN)
; References: 1,2
MID 969 96901 96901 96901 96904 96905 0
;
; Material: WOOD, WHITE FIR (ACROSS GRAIN)
; References: 1,2
MID 970 97001 97001 97001 97004 97005 0
;
; Material: WOOD, WHITE PINE (ACROSS GRAIN)
; References: 1,2,27
MID 971 97101 97101 97101 97104 97105 0
Main Index
660 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Materials References, Classification, Quality Code and Index
Main Index
Appendix C: PATQ Preference Program
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
J Overview 662
J Template File (TEMPLATEDAT) 685
J
PATQ Limitations 707
J Patran Thermal Execution 708
J Translation of Patran Thermal Input to SINDA 720
J Using TRASYS Translator 754
J Using NEVADA Translator 760
Main Index
662 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
Overview
PATQ is an interface program that provides communication links between Patran, QTRAN, VIEW
FACTOR, SINDA, TRASYS and NEVADA. In a nutshell, this is all that PATQ does. However, some
of these communication links are fairly sophisticated.
Typical communications tasks include the following:
• Manipulating material property database files.
• Conversion of a Patran neutral file to QTRAN and VIEW FACTOR input data files.
• Generation of a QTRAN main program from QTRAN input data files.
• Conversion of a QTRAN text output file to Patran Plus neutral file format or nodal results file
format.
• Conversion of a QTRAN text output file or nodal results file sequence to X-Y plot file format for
P/PLOT.
• Conversion of QTRAN binary input files to text files.
• Generate thermal load conditions for a stress code from QTRAN nodal results files.
• Direct conversion of QTRAN nodal results files to Patran neutral file format. This is useful for
applying thermal loads directly to an identical structural model.
• A SINDA input file can be generated from the QTRAN input files that have been generated by
PATQ.
• A TRASYS input file can be generated with QTRAN vfindat and templatedat files. The
TRASYS output can be translated back to QTRAN or SINDA input for further thermal analysis.
• A NEVADA input file can be generated with QTRAN vfindat and templatedat files. The
NEVADA output can be translated back to QTRAN or SINDA input for further thermal
analysis.
Main Index
Appendix C: PATQ Preference Program 663
Overview
Quit
This option simply exits the PATQ program.
Note: If only boundary conditions have changed form a previously run model (i.e., all the
necessary files exist in the current directory) use PATQ utility pick 14 to redefine only files
associated with boundary conditions.
Main Index
664 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
Main Index
Appendix C: PATQ Preference Program 665
Overview
(continued)
With menu pick 2, PATQ uses the following 3 input data files:
1. Patran neutral file with the thermal model in it,
2. TEMPLATEDAT file (a template file in the local directory), and/or
3. TEMPLATEBIN file that is in the Patran Thermal root directory (THERMAL$DIR:[LIBRARY]
on VAX systems).
Main Index
666 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
The Patran neutral file must contain all of the Phase 2 data associated with the model (nodes, elements,
element properties and boundary conditions).
The TEMPLATEDAT file (see the TEMPLATEFILE subsection for more information) contains
auxiliary data that aids PATQ in the translation of the neutral file.
The TEMPLATEBIN file located in the Patran Thermal root directory (THERMAL$DIR:[LIBRARY]
on VAX VMS systems) contains MID templates for all materials included in MSc.Software Corporation
thermal material property database files (MPIDMKS, MPIDIPS, MPIDFPH, and MPIDCGS also located
in the Patran Thermal root directory). If PATQ encounters an MID number in the Patran neutral file and
cannot find a corresponding MID template in your local TEMPLATEDAT file, PATQ will attempt to
find the missing MID template in the TEMPLATEBIN file. If the MID template is not found, PATQ will
abort the translation process. If PATQ does find a matching MID template in TEMPLATEBIN, PATQ
will append the MID template to the local TEMPLATEDAT file and also write out a message to the
screen.
PATQ menu pick 2 will generate 19 Patran Thermal data files and (optionally) 1 VIEW FACTOR data
file. The Patran Thermal data files are as follows:
Main Index
Appendix C: PATQ Preference Program 667
Overview
PATQ will delete any data files that are empty at the end of the translation process initiated by menu pick
2.
The result of a successful translation process as outlined above is a collection of input data files for
QTRAN and VIEW FACTOR.
Main Index
668 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
After PATQ menu pick 2 is selected, PATQ will display a series of submenus. These submenus include
declaring the dimensionality of the problem as shown below.
Model Dimensionality
Table C-2 Dimensionality Options
If -2 is selected as the pick (2-D axisymmetric R-Z), PATQ will also prompt which Patran axis to use for
the R and Z. This is necessary because Patran models only exist in 3-D Cartesian X-Y-Z space. Normally,
one would use the X-axis for R and the Y-axis for Z, since these are the two Patran axes that lie in the
plane of the graphics screen by default. However, when performing analyses on rotating machinery, such
as turbines, the Patran X-axis may be selected for the Z-axis and the Patran Y-axis may be selected for
the R-axis. This is perfectly allowable. Similarly, it may be necessary to choose some other combination
in order to maintain compatibility with some other analysis code that uses a fixed convention for R and
Z-axis. For example, some structural codes require the use of the X-axis for R and the Z-axis for Z.
The Patran Thermal convention regarding 2-D elements is that all 2-D Cartesian elements are of unit
thickness, (i.e., they have a depth of 1 unit parallel to the Z-axis). All 2-D axisymmetric elements are
rotated through a complete 360° rotation (i.e., the elements are toroidal or ring elements).
Units Conversion
PATQ will also ask if a units conversion on nodal coordinates needs to be performed. This allows a
Patran model that was built in one system of units (e.g., inches) to be transformed to another system of
units that may be more compatible with the data available for the thermal model (e.g., meters). This
conversion operation effects all element surface areas, cross-sectional areas, and thicknesses. It
specifically does NOT operate on anything else. For example, this conversion process will affect the units
that element surface areas are given in, but will not affect the units that heat fluxes are given in (e.g.,
Watts/m2 vs. Btu/in2). If converting a Patran model from inches to meters, make sure that the heat fluxes
are given in units of power/m2 in the Loads/BCs menu. Note that 2-D triangular and quad elements are
always assumed to be of unit depth, even after the coordinate transformation.
Main Index
Appendix C: PATQ Preference Program 669
Overview
be edited first. The default QINDAT file is set up for a steady-state run with the standard execution option
as the defaults. If none of the options are going to be exercised which will change array sizes such as print
or maximum time step staging times, and the standard solution module will be executed, then it is
probably safe to use the default directory to create the main module even though the start, stop times, and
print interval will have to be changed with the editor before the job is executed. The preferred way is to
have the QINDAT file edited prior to executing the PATQ module.
QTRANFOR Generation
The purpose of PATQ menu pick 4 is to generate a new QTRAN main program source file, QTRANFOR.
This menu pick is performed after the following steps:
1. Having successfully translated a Patran neutral file with menu pick 2;
2. Optionally having successfully executed the VIEW FACTOR program to generate radiosity
network data for the VFRESDAT file. See Introduction (Ch. 1) in the Patran Viewfactor Analysis;
3. Having generated any material property data that is not contained in the MSc.Software
Corporation thermal material property database with the system editor in the MATDAT file;
4. Having generated any necessary QTRAN MICROfunction data in the MICRODAT file (see
Thermal/Hydraulic Input Deck (Ch. 8)); and
5. Having copied and modified (as necessary) a QINDAT QTRAN input data file.
After successfully generating a new QTRANFOR main program source file (Menu Pick 4), select menu
pick 5 to compile the QTRANFOR file into a QTRANOBJ object file, link with the QTRAN library files
QTRANOLB and ULIBOLB generating the QTRAN executable QTRANEXE, and submitting
QTRANEXE for batch execution. This is shown schematically in Figure C-1.
These four BIN files contain identical information, but in different units systems. These binary files are
direct access format. It is possible to, delete, copy, or modify these files at will by editing the text files in
MATDAT format and converting them with PATQ utility menu pick 2.
Main Index
670 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
The binary MID template file TEMPLATEBIN contains the MID templates for these files (all of these
files use the same MPID numbers for the same material properties, so they all require identical MID
templates). A text version of TEMPLATEBIN is provided as TEMPLATETXT and is also located in Mid
Templates Supplied in Templatebin and Templatetxt (App. B). If the MPID files are modified also modify
the TEMPLATETXT file accordingly. Using PATQ utilities menu pick 2, generate an updated
TEMPLATEBIN file that will reflect the changes to the MPID files.
If PATQ encounters an MPID number that has not been defined in the local MATDAT file, and it is
decided not to search the MPIDxxxBIN files, PATQ then aborts the QTRANFOR generation process.
Likewise, if PATQ cannot find a referenced MPID number in either the local MATDAT file or in the
MPIDxxxBIN file that is specified, PATQ will abort the process.
When PATQ searches through one of the MPIDxxxBIN files (as directed by the user) and finds a match
for the specified MPID number, PATQ will then copy the MPID data set from the MPIDxxx file and
append it to the local MATDAT file.
There is currently no practical way to scan through the material property files looking for a particular
material or data set. The most straightforward way is to find the material of interest in Appendix C or in
the TEMPLATETXT file by using the system editor (this file is considerably shorter than any of the
MPIDxxx files). Once the material is located use the system editor to search through the appropriate
MPIDxxx file to examine the MPID data sets for that material.
Main Index
Appendix C: PATQ Preference Program 671
Overview
The first option converts a template file containing only MID templates in text form to a binary file
TEMPLATEBIN. The system administrator may replace the TEMPLATEBIN file which MSc.Software
Main Index
672 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
File Structure
Record 1 Record_A Record_B
Record 2 MPID data
Record A Index
through B
For more information on material property database options, examine the text for main menu pick 4,
“QTRAN.FOR GENERATION”.
This menu pick can also be used to semi-automatically retrieve material property data sets from the
MPID files located in the Patran Thermal root directory (THERMAL$DIR:[LIBRARY] on VAX
systems).
Main Index
Appendix C: PATQ Preference Program 673
Overview
Column Value
1 Temperature
* These values are not put in the nodal results file if it is created from a QOUTDAT file.
Main Index
674 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
1. QUIT
This option simply quits and returns to the top level PATQ menu.
2. NODAL RESULTS
If menu pick 2 is selected (or simply hit the RETURN key), PATQ will build a temperature vs.
time plot file from a series of QTRAN nodal results files named NRnnnNRF in sequence. PATQ
will prompt for the name of the temperature vs. time plot file name, as well as for the “nnn” value
for the first nodal results file to be included in the X-Y plot file (the default “nnn” value is 0). The
X-Y plot file name will be the name of a file suitable for reading into Patran’s X-Y plot module
for display. PATQ will also prompt for the node number whose history to plot and the nodal
results file column number to use. Column number 1 from the nodal results file is temperature (the
default), column number 2 is the net nodal heat flow rate, and column number 3 is the explicit
stable time step for the node.
3. QOUTDAT FILE
If menu pick 3 is selected, PATQ will attempt to build the temperature vs. time plot file from a
QTRAN output file such as QOUTDAT (PATQ will prompt for the actual QTRAN output file
name). PATQ will also prompt for two other file names--a “Plot File” and an “X-Y Plot File”. The
Plot File refers to a print-plot file suitable for printing on a line printer, while the X-Y “Plot File”
refers to a file suitable for reading into Patran’s X-Y plot utility. This utility will prompt for the
minimum and maximum expected temperatures for the node, as well as the node number for
which temperature history data is desired. Since this utility operates off of a text QOUTDAT
(possibly renamed to something else), it is somewhat slower than the X-Y plot file utility that
operates off of the nodal results files. Also, while this utility generates both a print-plot file and
an X-Y plot file, it can only work with temperature data from QTRAN. The advantage of this
print-plot utility is that it is nice for getting a relatively accurate and quick temperature history
data for nodes and a graphics terminal is not needed to interpret the results.
Main Index
Appendix C: PATQ Preference Program 675
Overview
they are correct. Furthermore, PATQ actually “merges” parallel and nonlinearly similar resistors prior to
placing the resistors in the CONDUCDAT file. This further dims the ability to interpret the accuracy of
these resistors.
The binary capacitor data in CAPDAT is also generated from the Finite Element translation process; but,
because it is generated using the lumped capacitance matrix approach to Finite Elements, the capacitance
data has somewhat more of a parallel to the physical geometry of the elements. However, PATQ also
merges parallel and nonlinearly similar capacitors (capacitors which have the same material properties)
in the same manner as the conductive resistors. As with the conductive resistors, node numbers and
MPID numbers make sense, but interpreting the capacitance volumes is not straightforward.
The QPLOTDAT is a compact binary file that contains three header records, a time information record,
and a node temperature record. To examine this file or take it to a different system to do postprocessing,
it would be necessary to create an ASCII file with FORTRAN control characters. The format of the
output file, QPLOTTXT, would include the three 80-character header records. These contain the version
of the code used for the analysis, the date and time that the analysis was executed and a title identifying
the run. A time stamp record then precedes each group of temperatures output. This record contains the
time at which the temperatures apply, the number of temperatures output, and a statement indicating if
the solution was the result of a transient or steady-state calculation. The node number and corresponding
temperature in the ICCALC units follow.
Main Index
676 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
PATQ’s next prompt is for the TO neutral file. The TO neutral file refers to the name of the neutral file
containing the structural (although it can in fact be thermal or any other Patran neutral file) model that
the temperatures are mapped TO. The default file name is PATRANOUT.
The next prompt is for the MAPPED neutral file name, with the default being PATRANMAP. The
MAPPED neutral file is where all of the temperature LBC (packet 10) data goes that is generated by the
interpolation process. It is this MAPPED neutral file that is normally read in by Patran to apply the
interpolated temperatures as thermal load conditions to a structural model. For example, suppose that a
structural model Patran database is named STRUCTDAT. Execute Patran using the STRUCTDAT file
as the “old” Patran database and then read in the MAPPED neutral file (e.g., PATRANMAP) thermal
load cases for the structural model.
The next prompt from PATQ is for the tolerance value, with a default of 0.01. This tolerance value is
used to determine how far away a node should be from a thermal element before it automatically becomes
ineligible to be paired with that thermal element. The 0.01 default value is obviously totally arbitrary,
since a “good” tolerance value is extremely problem and units dependent. From a user’s standpoint, a
small tolerance value has two effects. First, it speeds things up because it eliminates many pairing
possibilities via very quick “box” tests. That was the good news. The bad news is that near curved
boundaries may disallow some pairings that should occur (see Figure C-2).
Main Index
Appendix C: PATQ Preference Program 677
Overview
The program will calculate a minimum tolerance based on the spread of the node locations and the
number of elements and nodes. If this value is smaller than that specified by the user it will be used as
the initial guess in determining which nodes should be associated with which element. A recursive
procedure is used in the selection process. If nodes are not within the tolerance a larger tolerance is used
to evaluate all the nodes that didn’t fall within last tolerance used. The user can input a single tolerance
or a maximum and minimum value with the number of cycle to be used to move between the minimum
and maximum values. If the code had computed a tolerance smaller than specified by the user an
additional cycle is added to the recursive process. A logarithmic interpolation between the minimum and
maximum values is used to determine the intermediate tolerance values.
Figure C-3 demonstrates how structural nodes with a dissimilar mesh can lie outside of thermal elements
near curved boundaries, even though both meshes model the same solid. As can be seen below, this
occurs when curved boundaries are represented by chords generated from the sides of an element that is
not of sufficient order to exactly model the curvature of the solid. Here, we have linear elements
approximating a distinctly nonlinear curved boundary. The result is that there are gaps between the
element sides and the curved boundary of the solid. The structural nodes should be within a user-
specified distance (tolerance) of the thermal elements if interpolation is to take place.
The interpolation process consists of two major steps. The first step is to determine the thermal element
that each structural node should be associated with. The second step is the actual interpolation process.
Step one involves determining how far away each structural node is from each thermal element. If the
distance is within tolerance, the thermal element with the shortest distance becomes the owner of the
Main Index
678 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
structural node. If no thermal element is within tolerance, then no temperature data is generated for the
structural node and the structural node is declared to be out of tolerance. As long as the structural node
is inside of some thermal element, life is very easy. Since temperatures are continuous from element to
element (i.e., the elements guarantee C0 continuity), ambiguities which arise due to a structural node
being on the boundary of one or more thermal elements does not even present any problems. Simply pick
an arbitrary thermal element from any of the boundary elements and the C0 continuity guarantees that
the same answer is obtained no matter which of the boundary elements are picked. If the structural node
is actually in the interior of some thermal element, that element by definition owns that structural node.
To actually perform the interpolation, the parametric coordinates must be computed (here referred to as
R, S, and T coordinates) for the structural node relative to the thermal element that owns it. See
Figure C-4 and Figure C-5. This is done with a simple Newton-Raphson routine. Once the R, S, and T
coordinates have been computed, interpolation can be performed by simple substitution into the
element’s basis functions and using the appropriate nodal results files.
First a “real space” element is mapped into parametric space as in Figure C-4.
After passing a rudimentary “box test” to verify that the structural nodes are within a rectangular
tolerance envelope of the thermal elements, the structural nodes not eliminated by the box test are also
mapped into parametric space. See Figure C-5. If their parametric coordinates are within +1 to -1, they
are definitely inside the thermal element and temperature interpolation. If they are not in this range, the
parametric coordinates are “clipped” to +1 or -1 and the real space coordinates of the clipped point are
then computed.
Figure C-4 Mapping a Thermal Element from Real Space to Parametric Space
Main Index
Appendix C: PATQ Preference Program 679
Overview
Figure C-5 Box Test Quickly Excludes Nodes which are Clearly Outside of the User
Assigned Tolerance Bounds. Next, Parametric (R<S) Coordinates are
Calculated for Nodes Which Pass the Box Test. The (R,S) Coordinates are
Clipped (Limited) to ± 1
As mentioned earlier, this is all very straightforward as long as the structural node actually lies within or
on the boundary of some thermal element. Unfortunately, we do not always have this luxury. Sometimes
the structural nodes actually lie very close, but outside of the nearest thermal element. This typically
happens in models with a curvature. What PATQ does in this case is to compute the R, S, and T
parametric coordinates for the structural node, but it limits R, S, and T to the interval +1 to -1 (that is, it
“clips” the parametric coordinates see Figure C-6). The +1 to -1 interval limits the computed parametric
coordinates to lying on the boundary of the thermal element. The real space (X-Y-Z) distance from the
clipped position to the structural node’s actual position is then compared to the tolerance value. If it is
within tolerance, this element can then be considered as an owner of the structural node. If it does become
the owner, the clipped R, S, and T coordinates are used in the element interpolation functions. This
prevents extrapolation beyond the element boundaries (which is what would result if R, S, and T were
not clipped), and this is very desirable since the interpolation functions are in general very poorly
behaved outside of the elements.
Figure C-4 and Figure C-6 show the results of “clipping” the structural node’s R and S parametric
coordinates so that they lie in the interval +1 to -1. The real space coordinates of the clipped point lies on
the edge of the element. The distance between this clipped point and the structural node’s true position
are compared to the user supplied tolerance value. If the distance is greater than the tolerance value, the
structural node is disallowed from being associated with this thermal element. If any other thermal
element pairing with the structural node results in a smaller tolerance, the other thermal element becomes
the owner of the structural node.
Main Index
680 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
PATQ generates a diagnostics file TOLERANCEDAT as a result of the structural node to thermal
element pairing operations. It lists the tolerance value (distance from the element edge to the structural
node), as well as the “clipped” parametric coordinates of each structural node. It also contains a brief
summary of all out-of-tolerance structural nodes.
The user will be asked if he desires to save the interpolation information between the given neutral files
for later operations.
After prompting for the tolerance value, PATQ next prompts for the starting Patran SID (set ID, or load
case ID) to use. This SID will be output with the neutral file packet 10s generated from interpolating the
first nodal results file. Every subsequent nodal results file used in the interpolation process will use an
incremented value of this SID.
After prompting for the starting SID, PATQ then reads in the FROM and TO neutral files. PATQ will
routinely indicate its progress in reading these files. If no errors are encountered in this process, PATQ
then proceeds with the structural node and thermal element pairing operations. If no problems are still
detected, PATQ indicates any out-of-tolerance nodes found and writes out the data to the
TOLERANCEDAT file.
PATQ then issues the following prompt:
Which column number from the nodal results files do you wish to
map values from (for QTRAN, column 1 is the column for
temperatures)? (default = 1, type STOP to stop)
Although any column may be selected from a nodal results file, column 1 is the only one that really makes
sense for QTRAN nodal results files.
Main Index
Appendix C: PATQ Preference Program 681
Overview
PATQ will continue to indicate its status during the course of the actual interpolation process. It is worth
noting that the interpolation process takes very little time relative to the structural node / thermal element
pairing operations.
After performing the interpolation process with the designated nodal results file, PATQ will then prompt
you with the following.
Do you wish to process another Nodal Results File?
(Y or N, default = Y)
If you answer Y, PATQ will then prompt you for the appropriate nodal results file and perform another
interpolation (PATQ does not have to go through the pairing operations again).
Important:The CONDUCDAT, VFRESDAT, and CAPDAT files are normally output in binary form
for a reason (i.e., they can be very LARGE when in text form). This menu pick translates
these binary files to text form files. Keep an eye on the available disk space. Also note that
the conversion from binary to formatted text form can take a nontrivial amount of CPU
time.
Main Index
682 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
the table limits. This is done by duplicating the beginning and ending table values. Other table types can
be bounded also. However, if a Hermite type table is being bounded, three table entries must be repeated
to limit the quadratic extrapolation. PATQ is also going to prompt for the desired starting, ending, and
increment desired for the converted property. Know these bounds before entering PATQ.
Main Index
Appendix C: PATQ Preference Program 683
Overview
Unlike the SINDA input which can generate a run ready deck, the geometry file must be included in an
edited version of the TRASYS run control deck. For further information, see Translating Patran Thermal
Model to TRASYS Input, 754.
Main Index
684 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
Main Index
Appendix C: PATQ Preference Program 685
Template File (TEMPLATEDAT)
Each of these template types is explained in the following subsections. Note that while unique TID
numbers for each template type must be used, the same TID numbers for different template types can also
be used. For example, there may be only one MID template with a TID of 1. However, there can be an
MID template with a TID of 1 and a MACRO template with a TID of 1.
Templates do not have to be sequentially ordered, nor do the template types have to be in any particular
order.
A sample TEMPLATE file is provided with the Patran Thermal software and may be accessed with the
“GET_QTRAN STARTUP” command at the system level.
Comments can be entered into the TEMPLATE file by beginning any line with an asterisk (*) or
semicolon (;). The remainder of any such line will be ignored.
The TEMPLATE file accepts free format input. Free format may be used to input data to the TEMPLATE
file.
Main Index
686 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
MID Templates
MID templates supply an intermediate “missing link” between Patran MID (material ID) numbers and
QTRAN MPID (material property ID) numbers. Since Patran is based upon material numbers and
QTRAN is based upon property numbers, and since it takes up to (6) property numbers to define a
material for the solid part of the model (thermal conductivity in the local X', Y', and Z' directions, density,
specific heat, and phase change data set), a way is needed to bridge this gap. The solution was to use an
MID template. Build one MID template for each material in the model. The MID template consists of the
characters “MID” and the template TID number followed by (6) MPID numbers. The MID number that
is assigned on the Element Properties form refers to an MID template with the same TID number.
The linkage system between Patran MID numbers and QTRAN material property data is as follows:
1. Assign MID numbers to the model with the Patran Element Properties form.
2. Build an MID template for each MID assigned to the model with Patran.
3. PATQ uses the MID templates to get the MPID numbers for the conductive resistors and
capacitors that PATQ will generate for QTRAN. This is done when the Patran Neutral File is
translated into VIEW FACTOR and QTRAN data files.
4. Build material property definitions. Each material property definition contains an MPID number
as part of the definition.
5. When QTRAN is executed, QTRAN will read in the material property definitions.
6. QTRAN will then match the material property definitions with the MPID numbers in the
conductive resistor and capacitor data files.
When PATQ is executed to translate the neutral file for the model, PATQ will read in the MID templates
and use the MPID numbers for the QTRAN data whenever it encounters an MID number in the neutral
file.
When QTRAN is executed and encounters the MPID numbers (and PHID numbers) in the resistor and
capacitor data, it matches these MPID numbers (and PHID numbers) with material property definitions
that have been supplied in a QTRAN input data file. These definitions are typically constants or data
tables of property vs. temperature, but the specifications may be any QTRAN material property
evaluation option. See Material Properties, 263.
For example, suppose 101 was entered in the material name data box on the Element Properties form. A
MID template 101 must be built prior to translating the model’s neutral file. Suppose that material 101
uses mopeds 1, 2, 3, 4, and 5 for thermal conductivity in the local X', Y', Z' directions, density, and
specific heat, respectively, and that it also will use phase change data set 121. The following MID
template could be used for this material.
The lines beginning with a semicolon are comments and may be omitted.
Main Index
Appendix C: PATQ Preference Program 687
Template File (TEMPLATEDAT)
Prior to executing QTRAN and running an analysis, material properties 1, 2, 3, 4, 5 and 121 must be
defined. This is typically done in the $INSERT file MATDAT. $INSERT files are referenced by QTRAN
input file(s) at execution time. See the introduction in Thermal/Hydraulic Input Deck (Ch. 8) for more
information about the $INSERT command. This chapter also contains additional data about material
property definitions.
If no phase changes are to be considered for a material, the PHID number for that material’s MID
template should be given as a zero. If the material is isotropic (Kx = Ky = Kz), the same MPID number
should be repeated three times for Kx, Ky, and Kz. For example, the following template specifies an
isotropic material with no phase changes allowed.
MACRO Templates
MACRO templates are used in conjunction with the Patran loads and boundary data to specify variable
heat source, temperature, pressure or mass flow rate boundary conditions. To explain what a MACRO
template is, it is required that you first understand the manner in which variable heat, temperature, mass
flow or pressure boundary conditions are applied with QTRAN. See Boundary Conditions, 322 for more
information.
Consider the following problem. You have a very complex time-dependent tabular heat source that you
wish to apply to a number of nodes. But each node is to get this time-dependent heat source scaled by an
equally complex temperature-dependent function, and further be scaled by the surface area associated
with each node. One way not to approach this problem is to build separate data table functions for each
node, especially if there are many nodes. Instead, it is more efficient to build the time-dependent data
table once and the temperature-dependent function once and assign function IDs to the time-dependent
and temperature-dependent functions. Let us call these little functions “microfunctions” since they will
be the little building block functions that we will use to build a complete heat source (or temperature
source). We will call the complete heat (or temperature) source a macrofunction (since it is made up of
one or more microfunctions).
Main Index
688 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
You could then assign a unique heat source to each node merely by referencing the microfunctions by
their ID numbers (MFIDs) and using a scale factor to account for the surface area associated with each
node. The scale factor could also account for any other constant scaling that must be performed (for
example, units conversions).
MACRO templates are used to define QTRAN macrofunctions. Macrofunctions are used by QTRAN to
specify heat source or temperature boundary conditions. See Heat Source/Sink Macrofunction Definition,
325 and Temperature Control Macrofunctions, 327 for more information about macrofunctions. The
macrofunction templates consist of the following data:
1. MACRO keyword.
2. Template ID number (TID).
3. The number of microfunctions that will be used to build the macrofunction.
4. Node numbers NODE1 and NODE2. NODE1 and NODE2 will be used as arguments for any
temperature dependent microfunctions.
5. A scale factor for the macrofunction.
6. A list of the ID numbers of the microfunctions that will be used to build the macrofunction
(MFIDs).
The scale factor that you use in the macrofunction template does NOT need to account for length, surface
area, or volume scaling. Patran and PATQ automatically account for this part of the macrofunction scale
factor. Instead the MACRO template scale factor is used as an additional constant scale factor to compute
the final macrofunction scale factor.
For example, suppose that a node has a surface area of 1.12 associated with it and that a heat source
macrofunction is being applied on a surface area basis. PATQ will take the surface area of 1.12 and
multiply it by the MACRO template’s scale factor. This product will be used in the macrofunction that
is assigned to this node by PATQ. Normally the MACRO scale factor is simply 1.0, but it may be any
value that you choose.
The NODE1 and NODE2 node numbers (see Boundary Conditions, 322) may be 0 or any valid node
number defined for your model. If either NODE1 or NODE2, or both NODE1 and NODE2, are entered
as zero, PATQ will supply the node number that the function is being assigned to in place of the zeros.
An example MACRO template is as follows.
Main Index
Appendix C: PATQ Preference Program 689
Template File (TEMPLATEDAT)
The lines beginning with semicolons are comments and are optional. This MACRO template has a TID
of 7, the number of microfunctions used to define the macrofunctions will be 3 (MFIDs 1, 2024, and 18),
NODE1 and NODE2 are given as 0 and 4157 (0 will be replaced by the node number to which the
macrofunction(s) is assigned), and a template scale factor of 1.0 (which will be used in addition to any
length-area-volume scale factors). The product of the macrofunction will be the output of microfunctions
1, 2024, and 18 and the resultant scale factor multiplied together.
Example
Suppose you wish to assign a distributed heat source boundary condition on a surface area basis to all
elements along edge 1 of patch 4. You would click on Loads/BCs on the main menu bar and select
Action: Create, Object: Heat Flux (pthermal), Type: Element Uniform or Element Variable. Select target
element type as 2D, then click on the Input Data and enter 23.7 for heat flux, 7 for template ID. Then
select edge 1 of patch 4 as application region and then click the apply button.
This command states MACRO template 7 will be used to build heat source macrofunctions on edge 1 of
patch 4. It will use the product of the scale factor in MACRO template 7 multiplied by the surface area
associated with each element and also multiplied by 23.7. This command is entered while still in Patran.
After the model is completed and a Patran Neutral File has been completed, add a MACRO template with
a TID of 7 to the TEMPLATE file. Let us assume the previous example template is used, but in a slightly
more compact form without the optional comments. The template would look like this:
MACRO 73041571.0
12024 18
The next thing necessary to do is to define what microfunctions 1, 2024, and 18 are (see Microfunction
Data, 322 and Microfunction Library, 440 for information about how to define microfunctions). After this
step, the distributed heat source boundary conditions that were assigned in Patran Loads/BCs form have
been completely defined. This is not particularly simple, but it is extremely versatile.
There are more examples of assigning MACRO boundary conditions in the Patran Thermal Tutorial,
complete with Patran commands, session files, TEMPLATE data files, and MICROFUNCTION data
files.
Variable temperature sources that are assigned use the same procedure, as do variable nodal heat sources.
Main Index
690 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
CONV Templates
Convective templates are used to specify variable convective boundary conditions. Remembering that all
you specify with Patran is a TID number and possibly some constant (or spatially varying) data, a
nonlinear convective analysis is obviously going to require more information such as material ID
numbers (MPIDs) and geometric properties (GPs). The template corresponding to the TID number
entered in Patran provides this information.
An example of a convective template is given below.
This convection template will be used by any Loads & Boundary Condition referencing TID number 1.
It states that the convective boundary condition uses QTRAN configuration 13 convective resistors
(natural convection from flat plates; see Reading Results (Ch. 6) which are for isothermal plates with
natural convection. Configuration 13 resistors require a total of 5 GP values, and you will notice that only
2 are given in this template. This is because the Patran always supplies GP #1 (surface area) and will
optionally supply GP #2 and GP #3 from the convection coefficient field of the convection loads and
boundary conditions (both GP #2 and GP #3 receive the same Cdata value). This template therefore
assumes GP #2 and GP #3 with the Cdata field will be provided, and the template then provides GP #4
and GP #5. For convective configuration 13 (natural convection from flat plates), the GP values are
defined by QTRAN to be:
• GP #1 - The surface area associated with the node is always provided by Patran and PATQ.
• GP #2 - A characteristic length of the plate (see Microfunction Library (Ch. 10)) (taken from the
convection coefficient value used in Patran convection loads and boundary conditions
referencing this template).
Main Index
Appendix C: PATQ Preference Program 691
Template File (TEMPLATEDAT)
• GP #3 - A second characteristic length (see Microfunction Library (Ch. 10)). This GP value is
taken from the convection coefficient field used in the Patran convection loads and boundary
conditions referencing this template. The GP #3 value provided by Patran and PATQ via the
Cdata field of the Patran convection loads and boundary conditions will always be the same as
the GP #2 value.
• GP #4 - Plate inclination angle in degrees. This value is given as 10.0 in the above template.
• GP #5 - Local gravitational constant, given as 9.8 from the above template.
This CONV template also states that MPIDs 1041, 1042, 1043, 1000, and 1110 will be used for the
convective resistors. Configuration 13 resistors require MPIDs for density, viscosity, coefficient of
thermal expansion, specific heat, and thermal conductivity. As an example of convection loads and
boundary conditions, enter 298.7 for convection coefficient, a convection template ID of 1 and fluid node
ID of 1000 on the convection Loads/BCs form in Patran. Then select edge 2 of patch 1 as application
region.
This command will assign convective resistors to edge 2 of patch1. GP #2 and GP #3 will be given values
of 298.7, CONV template number 1 will be used, and the resistors will be connected between the surface
nodes of edge 2 of patch 1 and bulk fluid node number 1000.
If no convection coefficient value had been given in Patran convection Loads/BCs form, the template
would have had to provide GP #2 and GP #3 as well. The template would then have looked as follows:
Convection loads and boundary conditions data using this second template would be 1 for convection
templateID, 1000 for fluid node ID and the convection coefficient data box left blank.
Main Index
692 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
The first Loads & Boundary Condition and the first CONV template have exactly the same effect as the
second Loads & Boundary Condition and the second CONV template. They are simply different ways of
doing the same thing.
In many configurations, GP #2 and GP #3 refer to the shortest and longest distances to the leading edge
of the convective boundary layer. This is obviously something that varies from element to element, and
may be entered as a Patran data line or data patch. To provide the same data supplying GP #2 and GP #3
in the template, it would require one template per element. This is somewhat less than ideal. We have
therefore provided the ability to assign spatially varying data for GP #2 and GP #3 from a Patran data
entity such as a data line or data patch. This is available but not necessary. For many analyses, simply
assume constant values of GP #2 and GP #3 and supply them from the template. There are also certain
configurations that do not require spatially varying information and it is very convenient to simply
include their GP #’s 2 & 3 directly in the template.
VFAC Templates
Radiative templates are used to specify all radiation boundary conditions. In addition to the data supplied
in the Patran View Factor Loads/BCs form (TID, MEDNOD, AMBNOD, CNVSID, NDB_Flags, and
ENCL_ID), additional data is necessary for radiation analysis. Specifically, either constant or variable
material property data is necessary for the emissivities and transmissivities (for either gray or
wavelength-dependent models) as well as the manner in which the transmissivities (if any) are to be
calculated. In addition, whether or not the model is gray or wavelength-dependent needs to be specified,
and also, what are the wave band boundaries. This additional information is supplied using the VFAC
templates.
The format for VFAC templates is given as follows. The square bracket nesting [ ] indicates successive
levels of optional parameters.
Main Index
Appendix C: PATQ Preference Program 693
Template File (TEMPLATEDAT)
0 -->The transmissivity for the view factor resistors will be calculated directly from
the material property referenced by the number or from the constant transmissivity
value (given in the below template as 0.915) if the number is 0.
1 -->The transmissivity for the view factor resistors will be calculated using either
the material property referenced by the number or the constant transmissivity value
as an extinction coefficient coupled with the view factor distance.
Collapse OPTIONAL--DEFAULT = 0, where:
0 -->Do not collapse radiosity nodes associated with a given surface node.
>0 -->Collapse radiosity nodes with the same collapse field value. This is a feature
to reduce the size of the radiation network.
Main Index
694 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
This template will be used by Patran View Factor Loads/BCs form referencing VFAC template number
1. It declares that the radiative boundary condition is gray (Nbands = 0), that the transmissivity of the
view factor resistors will be calculated from an extinction coefficient (Kflag = 1) and that the extinction
coefficient is a constant of 0.915, and that the emissivity of the surface resistors will be taken from
material property MPID 9275609. The collapse value of 5 will be used as an ID to flag radiosity nodes
which can be collapsed to a single radiosity node associated with a surface node.
VFAC template 2 above defines a gray surface (Nbands = 0) using variable material properties for
emissivity (MPID 7) and transmissivity (MPID 23). The transmissivity will be calculated using MPID
23 as an extinction coefficient (Kflag = 1) along with the view factor distance.
Main Index
Appendix C: PATQ Preference Program 695
Template File (TEMPLATEDAT)
VFAC template 3 above assigns a gray radiative boundary condition with a constant emissivity of 0.95
and a constant transmissivity of 1.00. No 1/(F*A*(1- τ)) resistors will be generated from this template.
Radiative template 4 above assigns a black radiation boundary condition with a constant transmissivity
value of 1.0. No 1/(F*A*(1-τ)) resistors will be generated by this template.
Main Index
696 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
VFAC template 5 above defines 3 wave bands: 0.0-1.7, 1.7-5.2, and 9.9-1.0E+10 microns. Wave band
#1 uses MPID 7 as the emissivity material property, and MPID 9 as the extinction coefficient. Wave band
#2 uses 1.0 as the emissivity (black surface, no (1-e)/(e*A) resistors generated for this wave band) and
0.915 as a constant extinction coefficient. Wave band #3 uses MPID 19 for emissivity and a constant 1.0
for the transmissivity (no 1/(F*A*(1-τ)) resistors generated for this wave band). Note that this template
does not define any wave bands between 5.2 and 9.9 microns. Presumably, this surface either does not
radiate in this wave band, or else the surface will have a view factor boundary condition, using at least
one other template to define the radiative boundary conditions within the 5.2-9.9 micron band. Normally,
an analysis will require one template for the entire spectrum, but cases do arise (e.g., greenhouse effects)
where the problem may need to be defined a little more creatively. Patran Thermal gives you great
flexibility.
VTRA Templates
This template defines the surface properties required by TRASYS. The radiation boundary condition is
specified the same as boundary conditions are defined for P/THERMAL and P/VIEWFACTOR. The
Main Index
Appendix C: PATQ Preference Program 697
Template File (TEMPLATEDAT)
surface properties are treated as constant in two different wavelength bands. One, the solar region which
is from 0 to a cutoff wavelength define in the TRASYS input and the IR region which is everything from
the cutoff wavelength to infinity.
The format for VTRA templates is given as follows. The square bracket nesting [] indicates successive
levels of optional parameters.
This template defines 0.2 as the surface absorptivity for diffuse surfaces with incident solar radiation and
70 percent of the solar energy will be transmitted through the material. If a specular analysis is performed,
the surface reflectivity will be 0.1. Corresponding values for the IR waveband are a surface emissivity of
Main Index
698 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
0.8, and opaque surface (transmissivity = 0.0) and if a specular surface is define the reflectivity will be
0.2. In this case, the reflectivity would be the same for both a diffuse or specular surface.
VNEV Templates
This template defines the surface properties required by NEVADA. The radiation boundary condition is
specified the same as boundary conditions are defined for P/THERMAL and P/VIEWFACTOR. The
surface properties are treated as constant in two different wavelength bands. One, the solar region which
is from 0 to a cutoff wavelength define in the NEVADA input and the IR region which is everything from
the cutoff wavelength to infinity.
The format for VNEV templates is given as follows. The square bracket nesting [] indicates successive
levels of optional parameters.
Main Index
Appendix C: PATQ Preference Program 699
Template File (TEMPLATEDAT)
As with the TRASYS input, this template defines 0.2 as the surface absorptivity for diffuse surfaces with
incident solar radiation and 70 percent of the solar energy will be transmitted through the material. If a
specular analysis is performed, the surface reflectivity will be 0.1. Corresponding values for the IR
waveband are a surface emissivity of 0.8, and opaque surface ( transmissivity = 0.0 ) and if a specular
surface is define the reflectivity will be 0.2. In this case, the reflectivity would be the same for both a
diffuse or specular surface. NEVADA actually calculates the absorptivity and emissivity from the
transmissivity and reflectivity data if they are variable. The reflectivity can be calculated from the
specified index of refraction. Currently, if variable reflectivity is to be specified ( a function of incident
angle ), the user will have to edit the NEVADA input file. Variable fields are not defined and translated.
Main Index
700 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
FLUID Templates
Fluid templates are used to specify all geometric and material property data necessary to evaluate the
variable hydraulic elements. Different fluid element options have different template formats and those
fluid options that have all constant properties do not require a fluid template.
The general format of the Fluid template is the FLUID keyword, the template ID, TID number of material
properties specified, and the option flag followed by the number of records necessary to indicate all of
the material properties desired. The template requirements are defined in Getting Started (Ch. 2).
Below are some examples which show the input for various fluid templates.
Main Index
Appendix C: PATQ Preference Program 701
Template File (TEMPLATEDAT)
Main Index
702 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
Main Index
Appendix C: PATQ Preference Program 703
Template File (TEMPLATEDAT)
Main Index
704 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
Main Index
Appendix C: PATQ Preference Program 705
Template File (TEMPLATEDAT)
Main Index
706 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Template File (TEMPLATEDAT)
Main Index
Appendix C: PATQ Preference Program 707
PATQ Limitations
PATQ Limitations
This subsection contains a brief description of certain limitations that exist in the PATQ program (e.g.,
maximum number of MID templates, etc.). Although it has been the author's philosophy to avoid coding
in such limitations (especially in QTRAN, where there are virtually NO coded limitations visible to the
user), expediency has caused a few such limitations to find their way into PATQ for the time being.
These limitations are as follows. First, MID templates may not have a TID number greater than 1000000
(remember also that all TID numbers must be greater than 0). MACRO templates TID number may not
be greater than 1000000. The total number of Microfunctions referenced by the MACRO templates must
not exceed 1000000. The maximum CONV template TID number may not exceed 1000000. The
maximum count of CONV template MPID values and GP values may not exceed 1000000. These
limitations are presented in a brief form below.
.
In general, the maximum values are high enough that they are unlikely to cause anyone serious problems,
but keep these limits in mind when building the thermal model.
Main Index
708 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
Note: The conductive resistors coming from PATQ are mathematical in nature and have no physical
basis (e.g., negative A/L ratios are not uncommon). Do not be alarmed. They are necessary
for the mathematical exactness of the translation.
4. If the problem involves the calculation of thermal radiation view factors, execute VIEW
FACTOR now. It will read the VFINDAT file generated by PATQ and will generate a QTRAN
input data file segment named VFRESDAT for radiative resistors.
5. Create (or edit an existing) QINDAT file. QINDAT is the QTRAN input data file. QINDAT
contains a number of run control parameters and other data necessary for QTRAN to execute. It
will normally contain a number of “$INSERT” filename commands. The $INSERT commands
cause the referenced file name to be inserted by QTRAN into the input data stream as QTRAN
executes. This keeps the QINDAT file rather small and reference the larger PATQ output files
with $INSERT commands. In addition to the PATQ output files, maintain the additional
Main Index
Appendix C: PATQ Preference Program 709
Patran Thermal Execution
$INSERT files (e.g., a MATDAT file for material property data and a MICRODAT file for
QTRAN microfunction data). It should be noted that QTRAN will honor ANY file name included
as a $INSERT file. There is nothing special to QTRAN about the PATQ output files. This allows
customized data files to be built for the particular applications.
6. Now the QINDAT file has been constructed or modified for the problem. This includes the
$INSERT commands necessary for any PATQ output files being used by the model as well as any
other data such as material properties, microfunction data, and the VIEW FACTOR VFRESDAT
file. Execute PATQ again. This time, select the menu option that will build a new QTRAN main
module. What PATQ does is read the QINDAT file that will be run through QTRAN and counts
up how large the array dimensions for QTRAN need to be. When the counting process is finished,
PATQ then writes out about 300 lines of Fortran into a file called QTRANFOR. QTRANFOR is
the QTRAN main module and consists of very little other than dimension statements and a call to
subroutine CRUNCH.
7. Now that QTRANFOR exists, compile it and link it to the QTRAN library. The results are in an
executable image of QTRAN that is optimally dimensioned for the problem. If using any user-
supplied subroutines, these subroutines must be included in the linking process. The exact
procedure will be installation-dependent. The user has the ability to execute a predimensioned,
predefined QTRAN executable which is in the thermal library with the name qtran_lib.exe. Even
if you are executing the predefined executable the step that create the QTRANFOR file should
still be performed as this step also loads any undefined material properties from the library.
8. Execute QTRAN. QTRAN will read in the QINDAT file and will generate the output files
STATBIN and QOUTDAT, as well as one or more Patran nodal results files named NRnnnNRF
(where nnn is an integer number corresponding to each QTRAN print dump). STATBIN is a
status file to which QTRAN continuously writes. QOUTDAT is the results output file for the
QTRAN run. QINDAT and QOUTDAT are text files. STATBIN is a binary direct access file that
can be queried by using the QSTAT utility provided with Patran Thermal. NRnnnNRF files are
standard Patran nodal results files containing temperature data as well as the net nodal heat flow
rate and the explicit stable time step for each node. The NRnnnNRF files can be read directly by
Patran, and they can also be used as restart files for QTRAN. PATQ can also convert the
NRnnnNRF files to a Patran neutral file format for use as thermal load conditions for structural
codes.
Steps 3 through 8 can be performed in Patran under the Analysis menu.
The qtran_lib.exe file in the p3thermal_files/lib directory can be replace with one tailored to one’s
specific needs. If the problem being executed terminates with errors associated with the problem
dimensions simply follow the normal run procedures in which the qtran.f file is compiled, linked
and run. The qtran.f file can be altered to better suit a users normal run environment or can be
linked with a users specific user library to a special executable. To have this new executable be
the standard executed when the direct execution option is flagged, simply replace the
qtran_lib.exe with the new qtran.exe created changing its name to qtran_lib.exe.
Execute Patran, and read the NRnnnNRF files and display the results of the analysis.
Main Index
710 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
PATQ Files
The files used by PATQ are as follows.
Main Index
Appendix C: PATQ Preference Program 711
Patran Thermal Execution
QINDAT This file is read by both PATQ and QTRAN. PATQ takes the QINDAT file and
generates a new QTRAN main program module named QTRANFOR.
QOUTDAT This file is generated by QTRAN and is read by PATQ. PATQ takes the
QOUTDAT file and (a) generates Patran nodal results files, (b) generates Patran
neutral file segments, or (c) generates time-temperature print-plots.
QPLOTDAT This file is generated by QTRAN and may be read by PATQ. PATQ takes the
QPLOTDAT file and converts it from binary to an ASCII file.
NRnnnNRF These files are standard Patran nodal results files generated by QTRAN. One
NRnnnNRF file is generated for each QTRAN print dump. PATQ can process
these files and convert them to NFnnnDAT files (standard Patran neutral files)
which can be used to apply thermal load conditions to structural models. PATQ
can also read a sequence of NRnnnNRF files and generate Patran X-Y plot files,
thereby allowing you to use Patran’s X-Y plot utility to display temperature
histories. Finally, PATQ also reads one or more NRnnnNRF files when it is
performing a temperature interpolation from a thermal mesh to a dissimilar
structural mesh.
* These values are not put in the nodal results file if it is created from a
QOUTDAT file.
TEMPLATEDA This file is read by PATQ and contains material property ID numbers along with
T boundary condition template data.
Main Index
712 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
THERMAL$DIR:[LIBRARY]TEMPLATEBIN
This file is read by PATQ and contains the default MID templates for the material
property database.
THERMAL$DIR:[LIBRARY]TEMPLATETXT
This file can be read by PATQ and converted to TEMPLATEBIN. The
TEMPLATETXT file is text and can by modified by your system manager using
a text editor.
THERMAL$DIR:[LIBRARY]MPIDMKS,
THERMAL$DIR:[LIBRARY]MPIDIPS,
THERMAL$DIR:[LIBRARY]MPIDFPH, and
THERMAL$DIR:[LIBRARY]MPIDCGS
These files are material property database files which can be read by PATQ when
generating a new QTRANFOR file. These text files can be modified with your
system editor. They contain the Patran Thermal material property definitions in
units of meters-kilograms-seconds, inch-lbms-seconds, foot-lbms-hours, and
centimeters-grams-seconds, respectively. These files are material property
database files which can be read by PATQ when generating a new QTRANFOR
file. These text files can be modified with your system editor. They contain the
Patran Thermal material property definitions in units of meters-kilograms-
seconds, inch-lbms-seconds, foot-lbms-hours, and centimeters-grams-seconds,
respectively.
THERMAL$DIR:[LIBRARY]MPIDMKSBIN,
THERMAL$DIR:[LIBRARY]MPIDIPSBIN,
THERMAL$DIR:[LIBRARY]MPIDFPHBIN, and
THERMAL$DIR:[LIBRARY]MPIDCGSBIN
These files are material property database binary files which can be read by
PATQ when generating a new QTRANFOR files. These files can be created by
executing PATQ utility menu pick 2. They contain the Patran Thermal material
property definitions in units of meters-kilograms-seconds, inch-lbms-seconds,
foot-lbms-hours, and centimeters-grams-seconds, respectively.
OLDMATDAT This file is read by PATQ and contains material property data to be translated to
LCI type material property tables.
PATQINP This file is an input file that contains all the responses to the PATQ menu request.
This file is required when batch submittals are executed with the PATQB or
OTRANB commands.
Main Index
Appendix C: PATQ Preference Program 713
Patran Thermal Execution
THERMAL$DIR:[LIBRARY]MPIDIPSBIN,
THERMAL$DIR:[LIBRARY]MPIDFPHBIN, and
THERMAL$DIR:[LIBRARY]MPIDCGSBIN
These files are material property database binary files which can be generated by
PATQ utility menu pick 2. They contain the Patran Thermal material property
definitions in units of meters-kilograms-seconds, inch-lbms-seconds, foot-lbms-
hours, and centimeters-grams-seconds, respectively.
QPLOTTXT This file is generated by PATQ from the QPLOTDAT file created by QTRAN and
converts it from binary to an ASCII file.
Main Index
714 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
NRnnnNRF These files can be generated by PATQ from a QTRAN QOUTDAT output file.
One NRnnnNRF file is generated for each print dump. Normally, this does not
have to be done because QTRAN generates these files automatically.
* These columns are not generated from QOUTDAT files using PATQ menu pick
5.
NFnnnNEU These files are the Patran neutral files generated by PATQ from a QTRAN
QOUTDAT output file, from QTRAN NRnnnNRF nodal results files, or from a
temperature interpolation operation.
TITLEDAT This file provide information about when and what versions of code were used to
generate the input file being executed. In addition it contains a user defined
description of the job.
PNODEDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains flow network node definition data (DEFPND cards).
NODEDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the node definition data (DEFNOD cards).
NODXYZDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the node location data cards in cartesian coordinates.
MATDAT PATQ will generate material properties if the material property selected does not
exist in the mat.dat file and is in the supplied P/THERMAL database. This file can
also be created by direct translation if material properties are specified by the fields
function in the Patran model. A mat.dat.apnd file in the model directory will be
appended to the mat.dat file in all subdirectories which are spawned from Patran.
Main Index
Appendix C: PATQ Preference Program 715
Patran Thermal Execution
CONDUCDAT This file is generated when a neutral file is translated. It contains the conductive
resistor data. This is a binary file. When used with the $INSERT command, the file
name should be followed with a “,C” to tell QTRAN that this is a binary conductive
resistor data file. For example:
“$INSERT CONDUCDAT,C”
FRESDAT This file is generated when neutral file is translated. It is an ASCII file and contains
the flow network resistor data.
CONVECDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the convective resistor data.
TRARSTDAT An ASCII radiation interchange file created by the reverse translation of a
TRASYS analysis.
NEVRST.DAT An ASCII radiation interchange file created by the reverse translation of a
NEVADA analysis.
RESDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains miscellaneous resistor data, including advective resistor data.
CAPDAT This file is generated when a neutral file is translated. It contains the capacitor data.
This is a binary file. When used with the $INSERT command, the file name should
be followed with a “,CAP” to tell QTRAN that this is a binary capacitor data file.
For example:
“$INSERT CAP.DAT,CAP”
TRAMICDAT Micro function tables to define the periodic heating on surfaces exposed to solar
radiation. This is created by the reverse translation of a TRASYS orbital analysis.
NEVMICDAT Micro function tables to define the periodic heating on surfaces exposed to solar
radiation. This is created by the reverse translation of a NEVADA orbital analysis.
QMCROD AT This file is generated when a neutral file is translated. It is an ASCII file and
contains the QMACRO function heat source data.
TRAQMADAT This is an ASCII file created by the reverse translation of a TRASYS analysis and
relates the micro function data to the QMACRO function heating definition for
each surface that receives solar radiation during an orbital flight.
NEVQMADAT This is an ASCII file created by the reverse translation of a TRASYS analysis and
relates the micro function data to the QMACRO function heating definition for
each surface that receives solar radiation during an orbital flight.
TMACROD AT This file is generated when a neutral file is translated. It is an ASCII file and
contains the TMACRO function temperature boundary condition data.
MMACRODA This file is generated when a neutral file is translated. It is an ASCII file and
T contains MMACRO function mass flow rate boundary condition data.
PMACRODAT This file is generated when a neutral file is translated. It is an ASCII file and
contains PMACRO function pressure boundary condition data.
Main Index
716 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
TFIXDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the node numbers of the fixed nodes.
PFIXDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the nodes numbers for which pressure is fixed.
TEMPDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the initial temperatures of nodes whose temperatures were assigned with
Patran Loads & Boundary Conditions.
PRESSDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains initial pressures of nodes whose pressures were assigned with Patran
Loads & Boundary Conditions.
QBASEDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the constant heat source data for nodes assigned constant heat sources
with the Patran Loads & Boundary conditions.
TRQBASDAT Average heat sources over an orbit defined from the reverse translation of a
TRASYS analysis. This file should not be included if the periodic heating is
defined.
NEVBASDAT Average heat sources over an orbit defined from the reverse translation of a
NEVADA analysis. This file should not be included if the periodic heating is
defined.
MDBASEDAT This file is generated when a neutral file is translated. It is an ASCII file and
contains the constant mass flow rate data for nodes assigned a constant mass flow
rate with Patran Loads & Boundary Conditions.
NEWMATDAT This file is created by PATQ with utility menu pick 11 and contains material
property data that has been translated to LCI type material property tables.
TEMPLATED The template.dat file will be created if materials are defined which are in the
AT P/THERMAL material database but were not defined in the template.dat file. If
direct translation is specified and a template.dat.apnd file is supplied in the model
create directory, it will be added to the template.dat file when the job is executed.
Main Index
Appendix C: PATQ Preference Program 717
Patran Thermal Execution
../CONVECDATAPND This file is created by the user and can be used to define any type
of conductor that the user wants added to any jobs submitted from
the Patran model. This file is placed in the directory in which the
model is created and will be pulled into any QTRAN execution
that is in a subdirectory associated with the model.
../CAPDATAPND This file is created by the user and can be used to define capacitors
that the user wants added to any jobs submitted from the Patran
model. This file is placed in the directory in which the model is
created and will be pulled into any QTRAN execution that is in a
subdirectory associated with the model.
../MATDATAPND This file is created by the user and can be used to define material
properties that the user wants added to any jobs submitted from
the Patran model. This file is placed in the directory in which the
model is created and will be appended to any mat.dat file that is
created while the job is being spawn for execution.
Main Index
718 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Patran Thermal Execution
../TEMPLATEDATAPND This file is created by the user and can be used to define materials
and their associated material properties that the user wants added
to any jobs submitted from the Patran model. This file is placed in
the directory in which the model is created and will be appended
to any template.dat file that is created while the job is being spawn
for execution.
../MICRODATAPND This file is created by the user and can be used to define micro
functions that the user wants added to any jobs submitted from the
Patran model. This file is placed in the directory in which the
model is created and will be appended to any micro.dat file that is
created while the job is being spawn for execution.
“$INSERT VFRESDAT,RAD”
QTRAN Files
QINDAT This file is the input data file for QTRAN. QTRAN will honor the command
“$INSERT filename” whenever it is encountered in the QINDAT file. QTRAN will
also honor a “$RESTART filename next_nnn_value” command, where filename
refers to a QTRAN nodal results file (i.e., one of the NRnnnNRF files). This is a text
file.
QOUTDAT This file is the output data file generated by QTRAN. This is a text file. For further
information see System Energy Balance, 221.
QPLOTDAT This file is the output data file generated by QTRAN. This is a binary file which
contains specified node temperatures at each converged iteration.
STATBIN This file is the status file generated by QTRAN. STATBIN is continually updated by
QTRAN during execution. This is a binary direct access file that may be accessed
with the QSTAT utility.
Main Index
Appendix C: PATQ Preference Program 719
Patran Thermal Execution
NRnnnNRF These files are the Patran nodal results files that QTRAN generates. One NRnnnNRF
file is generated for each QTRAN print dump, beginning with NR0DAT and
incrementing the “nnn” with each successive print dump. These files may also be
used as restart files for QTRAN. These are binary files in standard Patran nodal
results file format.
NRnnnASC These files are the Patran nodal results files that QTRAN generates if the ASCII flag
is selected. One NRnnnASC file is generated for each QTRAN print dump,
beginning with NR0ASC and incrementing the “nnn” with each successive print
dump. These are text files in standard Patran nodal results file format and can be
examined with the editor.
NPnnnNRF These files are the Patran pressure nodal results files that QTRAN generates for the
hydraulic nodes. Two values can be put in this file - pressure and net mass flow rate.
One NPnnnNRF file is generated for each QTRAN print dump, beginning with
NP0NRF and incrementing the “nnn” with each successive print dump. These are
binary files in standard Patran nodal results file format.
NPnnnASC These files are the Patran pressure nodal results files that QTRAN generates for the
hydraulic nodes. Two values can be put in this file - pressure and net mass flow rate.
One NPnnnASC file is generated for each QTRAN print dump, beginning with
NP0ASC and incrementing the “nnn” with each successive print dump. These are
text files in standard Patran nodal results file format and can be examined with the
editor.
NHnnnNRF These files are the Patran hydraulic element files that QTRAN generates for the
hydraulic network. Four values can be put in this file which represent elemental
quantities - mass flow rate, differential head, fluid velocity, and volumetric flow rate.
In addition to the selected values, the entrance and exit node number of the element
is specified. One NHnnnNRF file is generated for each QTRAN print dump,
beginning with NH0NRF and incrementing the “nnn” with each successive print
dump. These are binary files in standard Patran nodal results file format.
NHnnnASC These files are the Patran hydraulic element nodal results files that QTRAN generates
for the hydraulic nodes. Four values can be put in this file which represent elemental
quantities - mass flow rate, differential head, fluid velocity, and volumetric flow rate.
In addition to the selected values, the entrance and exit node number of the element
is specified. One NHnnnASC file is generated for each QTRAN print dump,
beginning with NH0ASC and incrementing the “nnn” with each successive print
dump. These are text files in standard Patran nodal results file format and can be
examined with the editor.
Main Index
720 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 721
Translation of Patran Thermal Input to SINDA
described earlier in Chapter 3. The following describes how these picks relate to SINDA input file
creation. Upon entering PATQ, the following menu will appear.
Select 2) and Patran Thermal reads the default TEMPLATE.BIN file in Patran Thermals root
directory, as well as a local TEMPLATE.DAT file which may exist in the current
directory. All the Patran Thermal files (TEMPDAT, CONDUCDAT, etc.) will be created
in the local directory.
Select 3) only if VFAC boundary conditions were created for radiation in Patran. This will execute
VIEW FACTOR in batch mode and create a VFRESDAT file that will be read later to
create radiation resistors in the SINDA input format.
Select 4) if material properties (k, rho, or Cp) need to be automatically read from the Patran
Thermal material library and inserted into the local MATDAT file. Otherwise this
selection can be skipped.
Select 6) to access the utility menu which is also described in detail in section 3.2.2. The utility
menu is where the actual translation to SINDA input occurs and is displayed on the next
page.
Main Index
722 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Select 15) to create the SINDA input deck from existing Patran Thermal files created in
the previous steps.
The first file read is the QINDAT file located in the local directory. The local directory is again searched
for a file called APPENDSIN This file contains parameters that affect the way the SINDA input file will
be created and also contains logic blocks and a subroutine that allows SINDA to write Patran nodal
results files. The Fortran files are appended to the bottom of the SINDA input file which is called
MODELSIN. The APPENDSIN file is discussed in detail in The APPENDSIN File, 746. If this file does
not exist, then the user is prompted as to which type of SINDA file to create:
After the user selects either “1” or “2”, the default APPENDSIN file will be written to the local directory
for future customization of SINDA files.
Note: It is recommended that all APPENDSIN files be deleted from the local directory before re-
executing the SINDA utility if the run is being changed from steady-state to transient (or
vice versa) or if the requested deck is being changed from SINDA85 to Network Analysis
SINDA (or vice versa).
Main Index
Appendix C: PATQ Preference Program 723
Translation of Patran Thermal Input to SINDA
The SINDA utility then proceeds to read MSC Patran Thermal files and creates the appropriate SINDA
input file. The following table shows a sample execution which indicates the files that are read from the
local directory and then displays a summary of the total number of nodes and conductors created.
Main Index
724 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 725
Translation of Patran Thermal Input to SINDA
Main Index
726 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
The number of conductors created for the SINDA file might be less than the number of conductors
created by Patran Thermal. This is done because Patran Thermal creates conductors between boundary
nodes in case the desired classification needs to be changed to a nonboundary node during a transient.
If any errors occurred (such as modeling functionality) that SINDA does not support (such as
wavelength-dependent radiation), an error message will be displayed underneath the line that displays
which file is currently being read. All these messages are included in the PATQMSG message file.
Main Index
Appendix C: PATQ Preference Program 727
Translation of Patran Thermal Input to SINDA
Main Index
728 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 729
Translation of Patran Thermal Input to SINDA
Main Index
730 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 731
Translation of Patran Thermal Input to SINDA
Main Index
732 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 733
Translation of Patran Thermal Input to SINDA
Main Index
734 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 735
Translation of Patran Thermal Input to SINDA
Main Index
736 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 737
Translation of Patran Thermal Input to SINDA
Main Index
738 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 739
Translation of Patran Thermal Input to SINDA
Main Index
740 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 741
Translation of Patran Thermal Input to SINDA
Main Index
742 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
To understand how the Patran Thermal parameters are translated to SINDA, Table C-12 describes the
supported Patran Thermal to SINDA functionality. This table describes how a particular capability is
implemented for a particular function. Much of this information will become clear after translating
sample problem 1 for basic functionality and problem 10 which uses some of the more advanced
functionality with variable heat loads and convection coefficients.
Main Index
Appendix C: PATQ Preference Program 743
Translation of Patran Thermal Input to SINDA
Main Index
744 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 745
Translation of Patran Thermal Input to SINDA
Node Data The nodes are written to the MODELSIN file in the NODE DATA block in the
following order: diffusion (stores energy), arithmetic (massless), and boundary
(fixed temperature). As shown in Table C-12, a wide variety of options are
possible for the NODE DATA block. An arithmetic node can be created with
the NODE,#,ADD command in Patran. Nodes can have initial temperatures
specified in Patran, otherwise the “TINITL” parameter in the QINDAT file is
used to provide the initial temperatures. A node can also have a fixed
temperature with the “-1” parameter specified in the TEMP LBC as described
in Section 2.2.3.1 of this manual. Temperatures that reference macro and micro
functions are not supported for this release. This functionality would be
created by including the appropriate logic in the SINDA VARIABLES block.
Currently, 62,400 is the maximum number of nodes per translation.
Conduction If the MATDAT file specifies the thermal conductivity to be “Constant”, then
a constant conductor will be created in the SINDA deck. Time and temperature
varying conductors will be created if the material property is input into the
MATDAT file in a “TABLE” (or “ITABLE”). If ITSCAL is “T” for time, then
a time varying conductor (SIT for Network Analysis' SINDA) will be created.
See MPID Number, Function Type, Temperature Scale, Factor and Label
(p. 263) in the Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic
Analysis under Material Properties (Ch. 8) for a description of ITSCAL and
IEVAL. There is no limit to the maximum number of conductors per
translation.
Convection Convection with a constant heat transfer coefficient is specified as described
in Chapter 2 and also in sample problems 1 and 10. Problem 10 also
demonstrates how convection can be specified as a function of temperature.
This is done by creating a “CONV” template in the TEMPLATEDAT file
which references configuration 29. This configuration points to a table of
temperature versus heat transfer coefficient in the MATDAT file. Time
varying convection is done in a similar way except ITSCAL for the convection
MPID in the MATDAT file is “T” for time. Convection can also be created by
referencing a spatial varying convection field or data entity (data line, data
patch, or data hyperpatch). Other convection configurations are not supported
by the SINDA utility.
Radiation Gray body radiation with fixed emissivity is supported as in Section 2.2.3.5
with the VFAC LBC and in the users manual. These radiation resistors are used
in problem 10 and in all 3 example View Factor problems. Variable emissivity
and spectral radiation are not supported for the SINDA utility.
Advection Variable and/or constant mass flow rate and specific heat are supported for
advection. The hydraulic network functionality of Patran Thermal which
calculates pressure drops and flow rates is not supported for the SINDA utility.
Main Index
746 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Heat Source Heat sources are applied by using the HEAT LBC for heat flux or nodal heat
source respectively. Constant or variable heat values are supported. Variable
heat sources are allowed by using a table of independent variable (time or
temperature) versus heat with a MACRO function with microfunction 8. This
is the only microfunction supported. For temperature varying sources, “ARG”
is equal to “1” and for time varying sources, “ARG” is equal to “0” as specified
in MFID, Independent Variable, and Function Type (p. 323) in the Patran
Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis under
Microfunction Data (Ch. 8).
Run Control The run control parameters are taken from the QINDAT file in the local
directory. It is important to note that the SINDA utility will NOT look for any
nodes or resistors inserted directly into the QINDAT file. It will only read these
nodes and resistors from the appropriate files (nodedat, resdat, etc.) Table C-12
shows which run control parameters are read. All other parameters in the
QINDAT file are ignored.
Materials If the IEVAL parameter of the material property (MPID) in the MATDAT file
is T (or “IT”) for table, then the table will be put into ARRAY DATA. If the
value of ITSCAL (also in the MATDAT file) is different than the value of
ICCALC in the QINDAT file, then a conversion of the temperatures in the
MATDAT file will take place to match the temperature units specified by
ICCALC (the calculation units). A message in the array will note that this has
taken place. Any of the thermal conductivities and specific heats in the Patran
Thermal material library that are tables can be brought into ARRAY DATA.
The phase change properties in the MATDAT file will be ignored by the
SINDA utility.
Main Index
Appendix C: PATQ Preference Program 747
Translation of Patran Thermal Input to SINDA
Main Index
748 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 749
Translation of Patran Thermal Input to SINDA
Main Index
750 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
Main Index
Appendix C: PATQ Preference Program 751
Translation of Patran Thermal Input to SINDA
The APPENDSIN file is created for the user by the SINDA utility if a APPENDSIN file does not already
exist in the local directory. If the file does exist in the local directory, then the parameters will be read by
the utility and the logic blocks will be appended to the bottom of the SINDA input deck.
The six parameters are described below
Main Index
752 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Translation of Patran Thermal Input to SINDA
SINDA Format The choices are “BCD” or “HEADER”. This signifies that this file
is created for Network Analysis’ “BCD” format SINDA or SINDA
‘85 with “HEADER” format. It is recommended that all
APPENDSIN files be deleted from the local directory before re-
executing the SINDA utility if the run is being changed from
SINDA '85 to Network Analysis’ SINDA (or vice versa). The
SINDA utility will prompt the user as to which type of SINDA file
should be created next time since an APPENDSIN file no longer
exists in the local directory.
The remainder of the APPENDSIN file contains logic blocks for modification before being appended to
Main Index
Appendix C: PATQ Preference Program 753
Translation of Patran Thermal Input to SINDA
the bottom of the SINDA input file. Included in these logic blocks is a SUBROUTINE block. This block
contains a subroutine called “RESPAT” that allows SINDA to create a file or files with nodal results in
a format that Patran can read directly. These nodal results files are of the form “NR#SIN” where #
denotes the output number. The “RESPAT” routine can be called directly from SINDA much like a
“TPRINT” routine is typically called for printing temperatures to the SINDA output file. By default, this
subroutine call is put in EXECUTION (OPERATIONS DATA for SINDA ‘85) for steady- state runs and
in OUTPUT CALLS for transient runs.
Main Index
754 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using TRASYS Translator
Figure C-7 Mapping between the Viewfactor code subelemental areas and the TRASYS
Surface Nodes
Main Index
Appendix C: PATQ Preference Program 755
Using TRASYS Translator
In the above example the different item in the VFAC template which is used by Patran Thermal are:
The VTRA defines the surface properties required by TRASYS. The input definitions are:
Main Index
756 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using TRASYS Translator
The forward translation is done by executing PATQ. It assumes that you have already translated the
neutral file to generate the required QTRAN input files in a previous step - menu pick 2. This is followed
by a menu pick 6 which brings up the additional utilities menu and select menu pick 16 which will read
the vfin.dat file and reformat the radiating surfaces into polygons in the TRASYS format. The output file
for input to TRASYS is given the name trasys.inp. Each enclosure is defined as a BCS group with a 6
character name reflecting the enclosure number. Each radiating surface is given a TRASYS node ID
which is 10 times the Patran THERMAL surface ID. The parent Patran element ID and node ID’s are
identified in comment portions of the TRASYS surface declarations.
Some restrictions on how the TRASYS run should be made are: One, the units for TRASYS are BTU,
feet and hours. The thermal model, when it is generated in Patran, should be in these units. If the model
has different geometric units, the conversion should be exercised at the initial translation so that all
conduction, convection and radiation boundary conditions are in a consistent set of units. Two, since the
radiation resistor/conductors defined for Patran Thermal do not include the Stefan Boltzmann constant,
SIGMA should be set to 1.0 for the TRASYS run. If it is desired to make a run with SINDA, then the
SIGMA can be defined in the SINDA input. The desired output for the resistor network should be
directed to tape and punched output should be requested for the desired solar heat fluxes.
Main Index
Appendix C: PATQ Preference Program 757
Using TRASYS Translator
The user will continue to be queried for different options related to the type to reverse translation data is
desired and conversion units relative to the TRASYS analysis. TRASYS analysis determine heating
loads and viewfactors based on element entities. Since MSC THERMAL performs its analysis based on
the finite element approach and uses the nodal subareas, the heat fluxes and viewfactors from TRASYS
are distributed to each node of a given element based on the finite element shape functions associated
with the element in question. After all the fluxes and viewfactors have been distributed to each node they
are combined. As a result even though a finer distribution has been used to define the conditions at each
node, the heating and resistor network associated with the finite element network is of the same order one
would get from an elemental analysis. All the files created for input to MSC THERMAL at the user’s
option can be translated to SINDA format as well.
The user can define the output names. The default names are consistent with those included in the qin.dat
file and the information contained in each file is:
trdkmat.dat Time dependent material properties which are used by the dynamic radiation resistors
to define periodic varying viewfactors.
trdynrdk.dat Dynamic resistor definitions which will use the trdkmat.dat material properties to
specify variable radiation viewfactors.
trcdrc.dat These are constant radiation resistor to be used in conjunction with the time dependent
viewfactors when performing a dynamic analysis. Even though the entire enclosure
may indicate articulating surfaces, some changes may not vary enough to warrant the
added calculation associated with variable geometry.
travrc.dat Steady state or transient analysis which don’t have variable geometry do not need the
variable radiation resistors. I those cases the RADKs are based on average values
which are defined in this file.
tramic.dat The microfunction file which has the equivalent TRASYS periodic heat flux array
data. Used for both dynamic and transient analysis.
traqma.dat Qmacro function file which relates the microfunction data in the tramic.dat file to each
Patran/THERMAL nodal subarea.
trqbas.dat The average heating from TRASYS surface that is distributed to each
Patran/THERMAL nodal subarea. Only used for steady state analysis.
Main Index
758 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using TRASYS Translator
Patran THERMAL ambient node number which was included in the comment card. The second option
is to hard code "32767" as the TRASYS SPACE node number. The result is the same as option 1. The
third option for numbering the SPACE node is to number it the same as the ambient node ID in Patran
THERMAL multiplied by 10. This will circumvent the 32767 logic and allow the reverse translator to
strip the trailing "0" without changing the original Patran THERMAL space node number.
Main Index
Appendix C: PATQ Preference Program 759
Using TRASYS Translator
Main Index
760 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using NEVADA Translator
Figure C-8 Mapping between the Viewfactor code subelemental areas and the NEVADA
Surface Nodes.
Main Index
Appendix C: PATQ Preference Program 761
Using NEVADA Translator
In the above example the different item in the VFAC template which is used by Patran Thermal are:
Main Index
762 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using NEVADA Translator
The VNEV defines the surface properties required by NEVADA. The input definitions are:
The forward translation is done by executing PATQ. It assumes that you have already translated the
neutral file to generate the required QTRAN input files in a previous step - menu pick 2. This is followed
by a menu pick 6 which brings up the additional utilities menu and select menu pick 18 which will read
the vfin.dat file and reformat the radiating surfaces into polygons in the NEVADA format. The output
file for input to NEVADA is given the name nevada.inp. NEVADA only recognizes one enclosure thus
it is import to only include one enclosure in the model being translated. Each radiating surface is given a
NEVADA node ID which is 10 times the Patran Thermal surface ID. The parent Patran element ID and
node ID’s are identified in comment portions of the NEVADA surface declarations.
Some restrictions on how the NEVADA run should be made are: One, the units for NEVADA are BTU,
feet and hours. The thermal model when it is generated in Patran should be in these units. If the model
has different geometric units, the conversion should be exercised at the initial translation so that all
conduction, convection and radiation boundary conditions are in a consistent set of units. Two, since the
radiation resistor/conductors defined for Patran Thermal do not include the Stefan Boltzmann constant,
SIGMA should be set to 1.0 for the NEVADA run. If it is desired to make a run with SINDA, then the
Main Index
Appendix C: PATQ Preference Program 763
Using NEVADA Translator
SIGMA can be defined in the SINDA input. The desired output for the resistor network should be
directed to tape and punched output should be requested for the desired solar heat fluxes.
The Patran THERMAL NEVADA reverse translator treats the NEVADA ambient (space) node radk's
differently than other surface to surface radk's. In the forward translation to NEVADA from Patran
THERMAL, each element surface from Patran THERMAL is multiplied by 10 as it is written to the
NEVADA input deck. If the enclosure references an ambient node, then that node ID is added in a
comment card at the end of the NEVADA input deck. When creating a space node in Patran for
NEVADA translation, a space node ID of 9999 must be used.
Note: You can either use the RADRs from NEVADA or the radiation
couplings created by the view factor code or both.
nevmic.dat The micro function file which has the equivalent NEVADA periodic array data
nevqma.dat The qmacro function file which defines the NEVADA periodic heating to each
surface that is distributed to each Patran Thermal node.
nevbas.dat The average heating from NEVADA surface that is distributed to each Patran
Thermal node.
Currently, all these files are ascii. Either have the desired input files available or comment out the
undesired insert directives, so that only the desired options are loaded in the QTRAN run. For example,
both the average heating and periodic heating should not be defined for the same run. Examples of where
the new insert directives are located is shown below.
Main Index
764 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Using NEVADA Translator
Main Index
Appendix D: Example Problems
Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
D Example Problems
J Overview 766
J Example Problem Number 1--Steady State Conduction Problem
767
J
Example Problem Number 2--Transient Conduction Problem 768
J Example Problem Number 3--3-D Iron Cube Problem 770
J Example Problem Number 4--Nonlinear Convection Problem 771
J Example Problem Number 5--Nonlinear Temperature and Heat
Source Boundary Conditions 773
J Example Problem Number 6--Steady State Radiation 774
J
Example Problem Number 7--Sample of Advection/Convection
Coupling 776
J
Example Problem Number 8--Sample of User Routines 778
J Example Problem Number 9--Solution of a “Stiff” THERMAL Problem
with the Direct Solver 780
J Example Problem Number 10--Translate MSC.Patran Thermal Input
to SINDA Input 781
J Problem Number 11--Solution of a Hydraulic Problem 783
Main Index
766 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Overview
Overview
The example problems described in this section are delivered with the software. To run one of these
examples, type the following in a working directory:
1. % get_qtran
This brings up the selection of available examples.
2. Enter the problem directory desired after the prompt.
3. Type "*" to copy all the files for the example.
4. Execute Patran "patran".
5. Under the File menu, select Play Session File and choose the <problem_name>. ses file.
6. This will build the model and spawn the Patran Thermal job. Review the modeling forms to see
how the model was built.
Main Index
Appendix D: Example Problems 767
Example Problem Number 1--Steady State Conduction Problem
Introduction
Example problem 1 is a constant thermal boundary condition problem designed to help in understanding
the steps required for a complete Patran Thermal analysis and to develop intuitive visualization skills in
predicting expected results.
Main Index
768 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 2--Transient Conduction Problem
Introduction
Example problem 2 is designed to expose the user to Patran Thermal's material property evaluation
options and the required syntax for their use. The features, capabilities, and control parameters of the
translator will be demonstrated. This translator is a crucial element of the Patran Thermal system and
facilitates the creation and translation of input and output files. Finally, the user will be familiarized with
Patran Thermal's run control parameters. Remember, run control parameters provide the versatility
needed to control analysis results. It is the specification of these parameters that drives the analysis. The
example problem directs you to assign thermodynamic material properties to four different materials.
This is accomplished through a combination of accessing material templates supplied by MSc.Software
Corporation or defined by the user. You may define your own materials by directly entering data (via your
system editor) to your material data file; MATDAT. We will define one of our own materials, “artificial
unobtainium” by editing its properties into the MATDAT file in this example problem.
Main Index
Appendix D: Example Problems 769
Example Problem Number 2--Transient Conduction Problem
Main Index
770 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 3--3-D Iron Cube Problem
Introduction
Example problem 3 is designed to expose you to the considerations involved in performing 3-
dimensional geometry modeling and subsequent thermal analyses. Towards this end, we will examine
the problem of a 3-dimensional iron cube with liquid mercury flowing in a channel along one side. This
problem will require the use of advection for the transfer of thermal energy with the flow of the liquid
mercury. The assumption of convective resistance being negligible due to its high thermal conductivity
is acceptable since the advective fluid is liquid metal. The finite element mesh required needs to be fine
enough to handle the large temperature difference between the advective fluid and the iron cube.
Main Index
Appendix D: Example Problems 771
Example Problem Number 4--Nonlinear Convection Problem
Introduction
Example problem 4 is designed to build upon the model and concepts of example problem 3 within a
nonlinear convection environment. Convection heat transfer is a function of the media, its flow
characteristics, and the geometric relationship of the object to the media. These functions are referred to
as configurations. Each configuration is defined to be within a given class of convection correlations.
There are presently 31 specific configurations and 6 generic configurations available in Patran Thermal.
These configurations are listed in the Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic
Analysis. There are two classes of properties used as input for the convective resistors. These are:
geometric properties (GP) and material properties (MPID). We will use both forced and natural
convection over flat plates for this problem.
Main Index
772 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 4--Nonlinear Convection Problem
Main Index
Appendix D: Example Problems 773
Example Problem Number 5--Nonlinear Temperature and Heat Source Boundary Conditions
Introduction
Example problem 5 has been designed to expose you to nonlinear temperature and heat source boundary
conditions. Environmental temperature and heat conditions in thermal analyses are rarely constant. These
nonlinear conditions are defined in Patran Thermal through the use of macrofunctions and
microfunctions. Although the model geometry is no more complex than in the previous example
problems, the boundary conditions are more complex. These boundary conditions may consist of time
dependent and/or temperature dependent conditions.
Main Index
774 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 6--Steady State Radiation
Introduction
Example problem 6 will guide you through the construction of two separate radiation enclosures, one for
gray body radiation and another for wavelength dependent radiation. The radiation resistors are
developed using the VIEWFACTOR program.
Key Concept
Convection or conduction requires that a material is present for the transfer of heat energy to occur. A
material, however, is not needed for a surface to transmit heat to another surface by radiation. Two types
of radiation supported by Patran Thermal are gray body and wavelength dependent. A gray body surface
must have the absorptivity equal to the emissivity and that emissivity is constant over the entire
temperature range. Wavelength dependent radiation is a significant extension of the gray body theory
such that the normal radiosity is divided into discrete frequency bands with the emissivity and
transmissivity assumed to be gray within these frequencies. The VIEWFACTOR program then develops
the radiation view factors, from which radiation resistors are developed which Patran Thermal can
incorporate into the solution.
Main Index
Appendix D: Example Problems 775
Example Problem Number 6--Steady State Radiation
Main Index
776 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 7--Sample of Advection/Convection Coupling
Introduction
Example problem 7 will demonstrate a sample of advection/convection coupling in the context of a 3D
steady state analysis.
Goal
This exercise will familiarize the new user with the steps required to define the appropriate boundary
conditions for a P3THERMAL analysis involving advective/convective coupling.
Given
A stainless steel block with a hole in it is exposed on one side to an air mass flowing over it. The entire
block is initially at a temperature of 25 degrees C. The exterior air mass is large enough that it experiences
no temperature drop during the entire traversal of the block. The boundary layer growth begins at the
beginning of the block and flat plate heat transfer correlations are assumed to apply along this surface.
The interior of the block is cooled by an air mass flowing through a hole in the center of the block, only
in this case the mass of air flow is not great enough to prevent the air from being heated. Heat transfer
correlations which define the heat exchange for flow inside a tube are valid for this case. The air
originates in a plenum in front of the steel block, so the boundary layer for internal cooling begins at the
front of the block. Because of symmetry, it is only necessary to model half of the block.
The heating air on the exterior is 100 degrees C and is flowing with a velocity of 10 meters/second. The
interior fluid is also flowing at the rate of 10 meters/second with a mass flow rate of 5E-5 kg/second.
Find
Determine the steady state temperature distribution of the block.
Main Index
Appendix D: Example Problems 777
Example Problem Number 7--Sample of Advection/Convection Coupling
Main Index
778 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 8--Sample of User Routines
Introduction
Example problem 8 will demonstrate a sample of a Patran Thermal analysis utilizing user supplied
subroutines in the context of a 2-D transient analysis.
Goal
This exercise will familiarize the new user with the steps required to define the appropriate files and
boundary conditions for a Patran Thermal analysis involving user supplied subroutines.
Given
A section of square tubing is cast in a moist sand mold. A quarter symmetry model is developed. The
casting is poured in a room which is maintained at 25 degrees C. Ignore all risers and end effects and use
a 2-D model to represent the thermal problem. Assume perfect contact between the casting material
(material number 351) and the molding sand (material number 831). The casting material has an initial
temperature of 1600 degrees C. Heat is lost to the ambient environment at a constant heat transfer
coefficient of 500 W/m2-°C on all horizontal surfaces and 1000 W/m2-°C on all vertical surfaces.
The molding sand has an initial moisture content of 40 kg/m3 which can be vaporized. As it is vaporized,
it is assumed to be lost out the casting. For this exercise, only capture the energy absorbed in the fluid as
it is heated up and vaporized. Do not model any effects of the vapor flowing through the mold and treat
those areas that are above the vaporization temperature initially, the same as if it were going through a
heat up cycle. Continue to absorb energy until all the moisture has been driven from the sand.
Perform a transient analysis for at least 500 seconds.
Note: You will need to compile the fortran subroutines, umicro.f and uloop7.f located in the
subdirectory prob8a. This is done with the command:
% ulib uloop7.f
% ulib umicro.f
Main Index
Appendix D: Example Problems 779
Example Problem Number 8--Sample of User Routines
Main Index
780 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 9--Solution of a “Stiff” THERMAL Problem with the Direct Solver
Introduction
Example problem 9 has been designed to illustrate the thermally “stiff” problem. Patran Thermal has
Iterative (SOL=0) and Direct (SOL=2) solution options. For “stiff” THERMAL problems iterative
solvers tend to converge very slowly while direct solvers work very efficiently. The problem is solved
using both iterative and direct solvers and the run times are compared.
Figure D-9 Example Problem 9 - “Still” Thermal Problem with the Direct Solver
Main Index
Appendix D: Example Problems 781
Example Problem Number 10--Translate MSC.Patran Thermal Input to SINDA Input
Introduction
Example problem 10 has been designed to illustrate the translation of input prepared for a Patran Thermal
analysis to a format for input to SINDA. The necessary input files can be retrieved with the
GET_QTRAN command. The problem is a simple electronic chip made up of multiple materials with
convection, radiation and temperature boundary conditions. Both nodal and surface flux heat source are
applied to the chip. All of this problem translates to a SINDA input file even though not all functionality
of Patran Thermal cannot be translated to SINDA. For example, even though the entire radiosity network
is carried into the SINDA input definition, if variable emissivities are modeled, SINDA does not properly
calculate the radiation. The supporting routines necessary to handle this case have not been developed at
this time. If variable emissivities are modeled, an error message is generated and the remaining portion
of the problem is translated to SINDA input. The Patran Thermal convection library is another feature
that has not been developed for execution with SINDA.
Key Concept
The SINDA translation option takes the input files as generated by Patran Thermal and creates the input
in a format ready to be executed by SINDA codes whose input formats are compatible with Network
Analysis' version or the SINDA85 code. Create the inputs for this demonstration problem and execute
Patran Thermal with the iterative solver, the direct solver and the SINDA code. Because the inputs are
the same does not mean that all solutions will yield the same results. Methods of solution also contribute
to variations in results.
Main Index
782 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Example Problem Number 10--Translate MSC.Patran Thermal Input to SINDA Input
Figure D-10 Example Problem 10 - MSC Pastran Thermal Input to SINDA Input
Main Index
Appendix D: Example Problems 783
Problem Number 11--Solution of a Hydraulic Problem
Introduction
Example problem 11 has been designed to illustrate the usage of the hydraulic network option. This
example couples the hydraulic solution to a transient thermal solution. The necessary input files can be
retrieved with the GET_QTRAN command. The problem is simply a fluid flowing in a copper pipe that
has a linear variation in heating rate applied along its length. The fluid extracts the heat from the pipe by
a convective boundary condition that has a constant heat transfer coefficient. In this case the oil viscosity
has been altered to more dramatically illustrate the coupling of the hydraulic and thermal solutions.
Main Index
784 Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Problem Number 11--Solution of a Hydraulic Problem
Main Index
MSC.Fatigue Quick Start Guide
Index
MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic
Analysis
Main Index
2 MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Main Index
INDEX 3
K N
K_MPID, 301 natural convection, annular space between
Karlekar & Desmond, 600 concentric spheres, 386
keywords, QIN.DAT, 227 natural convection, enclosed spaces between
Kflag, 693 flat plates, 382
natural convection, generic, 409, 411
natural convection, horizontal cylinders, 378
L natural convection, inside horizontal tube, 395,
LABEL, 263 421
LAMBDA, 296, 693 natural convection, rectangular blocks, 375
Main Index
4 MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
Main Index
INDEX 5
Main Index
6 MSC Patran Thermal User’s Guide Volume 1: Thermal/Hydraulic Analysis
W
wavelength dependent radiative resistors, 291
wavelength dependent resistors, examples, 297
white, 600
X
X/Y Plots of Temperature vs. Time, 674
Main Index