AEIC CS8-06
15kV 100% 175 mil Insulation (.175)
15kV 133% 220 mil Insulation (.220)
25kV 100% 260 mil Insulation (.260)
35kV 100% 345 mil Insulation (.345)
WALL
#2
#1
1/0
2/0
3/0
4/0
250
350
500
750
1000
Solid Conductor
Stranded Conductor
Compressed Conductor
Diameter in Inches
Diameter in Inches
Diameter in Inches
Compact Conductor
Diameter in Inches
Over Insulation
Over Insulation
Over Insulation
Over Insulation
Industry
Standard
Min.
AEIC
0.610
0.700
0.635
0.725
0.620
0.710
ICEA
0.610
0.695
0.645
0.730
0.635
0.720
0.620
0.705
Min.
Min.
Min.
AEIC
0.645
0.730
0.675
0.765
0.655
0.740
ICEA
0.645
0.725
0.685
0.770
0.675
0.760
0.655
0.735
AEIC
0.680
0.770
0.715
0.805
0.690
0.775
ICEA
0.680
0.760
0.725
0.810
0.715
0.800
0.690
0.775
AEIC
0.760
0.850
0.730
0.815
ICEA
0.775
0.855
0.760
0.845
0.730
0.815
AEIC
0.810
0.900
0.775
0.865
ICEA
0.825
0.905
0.810
0.895
0.775
0.860
AEIC
0.865
0.955
0.830
0.915
ICEA
0.880
0.965
0.865
0.950
0.830
0.910
AEIC
ICEA
0.935
1.020
0.920
1.005
0.880
0.965
AEIC
1.025
1.115
0.980
1.065
ICEA
1.045
1.130
1.025
1.110
0.980
1.065
AEIC
1.150
1.245
1.100
1.185
ICEA
1.175
1.260
1.150
1.235
1.100
1.185
AEIC
1.340
1.440
1.280
1.370
ICEA
1.370
1.455
1.340
1.425
1.280
1.365
AEIC
1.485
1.590
1.430
1.520
ICEA
1.520
1.610
1.485
1.575
1.430
1.515
turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.
34
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility
PG-CA-0307
CABLE ACCESSORIES
AEIC & ICEA Cable Insulation Diameter
#2
#1
1/0
2/0
3/0
4/0
250
350
500
750
1000
Industry
Standard
Solid Conductor
Stranded Conductor
Compressed Conductor
Compact Conductor
Diameter in Inches
Diameter in Inches
Diameter in Inches
Diameter in Inches
Over Insulation
Over Insulation
Over Insulation
Min.
Min.
Min.
Over Insulation
Min.
AEIC
0.700
0.790
0.725
0.815
0.710
0.800
ICEA
0.700
0.790
0.735
0.825
0.725
0.815
0.710
0.800
AEIC
0.735
0.820
0.765
0.855
0.745
0.830
ICEA
0.735
0.820
0.775
0.865
0.765
0.855
0.745
0.830
AEIC
0.770
0.860
0.805
0.895
0.780
0.865
ICEA
0.770
0.855
0.815
0.905
0.805
0.895
0.780
0.865
AEIC
0.850
0.940
0.820
0.905
ICEA
0.865
0.950
0.850
0.935
0.820
0.905
AEIC
0.900
0.990
0.865
0.955
ICEA
0.915
1.000
0.900
0.985
0.865
0.955
AEIC
0.955
1.045
0.920
1.005
ICEA
0.970
1.060
0.955
1.045
0.920
1.005
AEIC
ICEA
1.025
1.115
1.010
1.100
0.970
1.060
AEIC
1.115
1.205
1.070
1.155
ICEA
1.135
1.220
1.115
1.200
1.070
1.155
AEIC
1.240
1.335
1.190
1.275
ICEA
1.265
1.355
1.240
1.330
1.190
1.275
AEIC
1.430
1.530
1.370
1.460
ICEA
1.460
1.550
1.430
1.520
1.370
1.460
AEIC
1.575
1.680
1.520
1.610
ICEA
1.610
1.705
1.575
1.670
1.520
1.610
#1
1/0
2/0
3/0
4/0
250
350
500
750
1000
Industry
Standard
Solid Conductor
Stranded Conductor
Compressed Conductor
Compact Conductor
Diameter in Inches
Diameter in Inches
Diameter in Inches
Diameter in Inches
Over Insulation
Over Insulation
Over Insulation
Min.
Min.
Min.
AEIC
0.805
0.900
0.835
0.935
0.815
0.910
ICEA
0.805
0.895
0.845
0.935
0.835
0.925
0.815
0.905
AEIC
0.840
0.940
0.875
0.975
0.850
0.945
ICEA
0.840
0.930
0.885
0.980
0.875
0.965
0.850
0.940
AEIC
0.920
1.020
0.890
0.985
ICEA
0.935
1.025
0.920
1.010
0.890
0.980
AEIC
0.970
1.070
0.935
1.035
ICEA
0.985
1.075
0.970
1.060
0.935
1.030
AEIC
1.025
1.125
0.990
1.085
ICEA
1.040
1.135
1.025
1.115
0.990
1.080
AEIC
ICEA
1.095
1.190
1.080
1.175
1.040
1.135
AEIC
1.185
1.295
1.140
1.245
ICEA
1.205
1.295
1.185
1.275
1.140
1.230
AEIC
1.310
1.425
1.260
1.365
ICEA
1.335
1.430
1.310
1.405
1.260
1.350
AEIC
1.500
1.620
1.440
1.550
ICEA
1.530
1.625
1.500
1.595
1.440
1.535
AEIC
1.645
1.770
1.590
1.700
ICEA
1.680
1.775
1.645
1.740
1.590
1.685
turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.
PG-CA-0307
Over Insulation
Min.
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility
35
CABLE ACCESSORIES
AEIC & ICEA Cable Insulation Diameter
1/0
2/0
3/0
4/0
250
350
500
750
1000
Solid Conductor
Stranded Conductor
Compressed Conductor
Diameter in Inches
Diameter in Inches
Diameter in Inches
Compact Conductor
Diameter in Inches
Over Insulation
Over Insulation
Over Insulation
Over Insulation
Industry
Standard
Min.
AEIC
1.010
1.110
1.045
1.145
1.020
1.115
ICEA
1.010
1.110
1.055
1.155
1.045
1.145
1.020
1.120
Min.
Min.
Min.
AEIC
1.090
1.190
1.060
1.155
ICEA
1.105
1.200
1.090
1.190
1.060
1.160
AEIC
1.140
1.240
1.105
1.205
ICEA
1.155
1.255
1.140
1.240
1.105
1.205
AEIC
1.195
1.295
1.160
1.255
ICEA
1.210
1.310
1.195
1.295
1.160
1.260
AEIC
ICEA
1.265
1.370
1.250
1.350
1.210
1.315
AEIC
1.355
1.470
1.310
1.420
ICEA
1.375
1.475
1.355
1.455
1.310
1.410
AEIC
1.480
1.600
1.430
1.540
ICEA
1.505
1.605
1.480
1.580
1.430
1.530
AEIC
1.670
1.795
1.610
1.725
ICEA
1.700
1.800
1.670
1.770
1.610
1.710
AEIC
1.815
1.945
1.760
1.875
ICEA
1.850
1.955
1.815
1.920
1.760
1.865
turer for proper selection of accessories. Diameters to be measured in accordance with 9.6.
36
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility