Vous êtes sur la page 1sur 4

Marine Fuel consumption RFQ Check List

Country:
Vessel name:
Vessel type:

Cyprus
____________

B Gas Limited
Ship/barge owner: __________________
B Gas Lydia
9043457
____________
IMO no.
__________________
LPG/C Tanker
2003
____________
DWT or TEU:
__________________

E+H Rep/SC

____________ Contact person:

__________________

Application data:
Type of vessel:
For Barge:

For Vessel:
Fluid type:

Barge Vessel
Loading and delivery
Loading
Delivery
Receiving Central
Receiving STB and BB
HFO
MGO

Flow range:
Density range:
Viscosity range:
Pressure:
Temperature:

IFO180
IFO500
Low Sulphur

min ____ mt/hr


min ____ kg/m3
min ____ cSt
min ____ bar abs
min ____ C

IFO380
IFO700
Low Low Sulphur

0.305 mt/hr
normal ____
0.85
normal ____ kg/m3
5
normal ____
cSt
2.0
normal ____ bar abs
90
max ____
C

max ____ mt/hr


max ____ kg/m3
max ____ cSt
max ____ bar abs

Please provide the following documents to know better about the existing pipe system:
PI&D (incl pipe diameter and flange norm e.g. DIN DN150PN16 or JIS150A10K)
Effective piping arrangement (rising, falling or horizontal pipe)
Preferred Meter location

Endress+Hauser
Metechnik GmbH & Co KG
79576 Weil am Rhein Germany

Phone
+49762197501
info@de.endress.com
www.endress.com

1/4

Additional required information:


Current way of measuring? (SOPs)_____________________________________________
The vessel is not fitted with flow meter and daily consumption is measured from service tank gauge glass
_______________________________________________________________________
Are historic data available (to compare the improvements)? __________________________
Historical data can be provided
_______________________________________________________________________
What is the motivation for new type of metering? __________________________________
Accurate measurement of actual fuel consumption
_______________________________________________________________________
Expectations (e.g. accuracy, savings etc)? ________________________________________
Fuel saving
_______________________________________________________________________

Additional requirements (Data Interface to upper systems)


________________________________________
_______________________________________________________________________
In which port, shipyard, repair yard could be the installation? _________________________
This is depending on the trade route of the vessel
_______________________________________________________________________
What has to be included in the scope of supply? Installation/commissioning/engineering?
Installation and commissioning
______________________________________________________________________
______________________________________________________________________

2/4

Example of Massflow Meter size (Promass 80E)with EN flanges


For detail Information please refer to technical Information TI 00061D/06/EN 13.2011

3/4

Dimensions of Promass 80E remote version


For detail Information please refer to technical Information TI 00061D/06/EN 13.2011
The maximum cable length between Sensor and remote version is 30m

4/4