Vous êtes sur la page 1sur 1

Preventive Mantenance on Z Compressors Z18-Z75

Period
T 1 2 0 3 5 3 3 3 6 7 8 1 7,17 9 8 10 every 2000 hours

Scope of Works
Take all readings

Type of Service Visit


A X X X X X X B X X X X X X X X X X C X X X X X X X X X X X X X E X X X X X X X X X X X X X X X X X X F X X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Check oil - top up if necessary Replace air filter Replace breather filter Check automatic drains (IC & AC ) Grease bearings of electric motor Intercooler drain check valve every Service Aftercooler drain valve 4000 hours Service Intercooler drain valve Replace oil filter every Service inlet valve 8000 hours O-rings check valve Chang Roto-Z Oil Overhaul inlet valve every HP balance piston diaphragm 16000 hours Overhaul check valve Replace bleed off muffler Replace drive coupling rubber set 12 Overhaul gearbox 13 Replace LP element with Exchange kit 14 Replace HP element with Exchange kit 15 Overhaul oil pump 16 Between(**) Key drive shaft 7 35,000 Piston air inlet valve 17 And By-pass valve unloading system 17 40.000 hours Pivot inlet valve shaft 19 HP discharge silencer 20 Spring, valve, circlip & orifice oil by-pass 21 Clean coolers 22 Replace buffers 4 Service electric motor (**) Can be extended subject to SPM readings and actual working condition. Note: Scope of works may vay from different models, based on factory's recommendations