Vous êtes sur la page 1sur 1

Project No.

DESIGN CALCULATION SHEET


D0468

Date
Jan-05

Sheet No. of

Computed by
T. Hassan

Subject Building

Footing 1 (Type I) Cargo

Checked by

Approved by
-

Design of Isolated Footing with Vertical Load Only - According to ACI 318M-99
Bearing Capacity Concrete Cylinder Strength (f ' c ) Soil density (Gs) Footing ID: f2 Ultimate Column Load Service Column Load Column Dimensions Length Width Footing Dimensioning Required Bearing Area on soil = = = 16.00 t/m2 300 kg/cm2 1.80 t/m3 Reif. Steel Ult .Strength (f y ) = 4200 kg/cm2

= = = = =

200.00 t 133.33 t 65.00 cm 30.00 cm

A1 = A2 =

0.20 m2 4.70 m2 200.00 t

trc tpc

9.17 m2

tpc

Lrc

tpc

Plain Concrete Dimensions Length 3.25 m = Width 2.90 m = Thickness 0.20 m = Final stress under P. C. footing Final stress under R. C. footing Nominal Bearing strength of column Nominal Bearing strength of footing

Chosen Plain Concrete Dimensions Length 3.50 m = Width 3.20 m = Thickness 0.20 m = = = = = 12.54 12.50 348.08 696.15 t/m2 t/m2 t t (Safe) (Safe) (Safe) (Safe)

Reinforced Concrete Dimensions Length 3.50 m = Width 3.20 m = Thickness 0.85 m = Depth 0.75 m =

Footing Reinforcement Bearing Pressure (Ultimate Load) 18.69 t/m2 = Max. Ult. Bending Moment (Sect. I-I) 24.37 m t/ m' = Max. Ult. Bending Moment (Sect. II-II) 25.23 m t/ m' = Bar sizes to be chosen are ( 12, 16, 20, 22, 25, 32, 40) As I-I = As I-I(chosen) = 8 f 16 15 cm2 (Asmin) 8 f 16 As II-II = As II-II(chosen) = 15 cm2 (Asmin) rb r = 0.07 Check Wide Beam Action ( Shear ) Area subject to Shear stress Maximum Allowable Footing Resistance For Shear Force Acting On Footing Due To Shear (Vus)

tpc Wrc

I II

/ m' / m'

tpc tpc Lrc tpc

= = =

2.16 m2 Vn = 0.85 * (( f ' c) ^ 0.5 * b * d / 6)= f 40.37 t < 186.23 t (Safe)

186.23 t

Check Two Way Action (Punching) 9.73 Area subject to Punching shear = 4.90 Perimeter Resisting Punching shear (bo) = Maximum Allowable Footing Resistance to Punching is the Least of : 10.85*((f ' c )^0.5*bo*d)/3 = 570.32 20.85*((1+2/bc )*(f ' c )^0.5*bo*d/6) = 548.38 30.85*(((as *d/bo)+2)*(f ' c )^0.5*bo*d/12) = 1158.09

m2 m t t t

where, b c is the ratio of long side to short side of the column, concentrated load or reaction area and, a s is 40 (for interior columns) Punching Force acting on Footing (Vps)
181311371.xls.ms_office - Rev. 1.0

181.86 t
1/1

<

548.38 t (Safe)
10/18/2013