Structural comments for elevated tank

1. Concrete sections in sap model must be defined as per WDG 2. Cracked sections must be defined as per ACI code 3. Wind loads must be assigned in model 4. Dynamic seismic force must be assigned 5. Analysis of tank must include Sequence of construction 6. Dynamic effect from water on tank must be reflected in model 7. All concrete sections must be designed as per ACI Design report must be submitted 8. Raft must be modeled with super structure 9. Raft design must be submitted 10. All connections between lifting slab and the main structure must be designed and submitted 11. Method of statement for constructing the tank must be submitted , including all the stages of constructions , methods and sketches.