Vous êtes sur la page 1sur 28

Security Level:

1+1 HSB-FD-SD Commissioning

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

CONTENT
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD

Basic Knowledge

1+1 Configuration
For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the

paired slots (slot6 and slot8) consist another 1+1 protection group.
Slot 5 and slot 6 is main slot respectively. For 1+1 HSB and SD application, It is only necessary to configure main IF board

parameters.
For 1+1 FD application, It is necessary to configure main parameters and standby

parameters respectively.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

Basic Knowledge

Trigger Conditions of the automatic HSB switching


Switching Conditions The hardware of the IF board is faulty. The hardware of the ODU is faulty. POWER_FAIL VOLT_LOSIF Board RADIO_TSL_HIGH RADIO_TSL_LOW RADIO_RSL_HIGH IF_INPWR_ABN CONFIG_NOSUPPORT R_LOC R_LOF R_LOS MW_LOF The IF connection cable is faulty.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4

Description

At the same priority.

Basic Knowledge

Trigger Conditions of the automatic HSM switching


Switching Conditions R_LOC R_LOF R_LOS MW_LOF MW_FECUNCOR B1_SD (IDU 620 PDH) B2_SD (IDU 620 SDH ) MW_BER_SDIDU 605 2B/2F Low Medium High Description

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

Basic Knowledge

Hybrid Coupler with Waveguide Interface

Coupler Type Asymmetrical Hybrid Coupler(6dB)

Description with one main channel and one standby channel.

Application

Receive Power Main ODU port insertion loss, dB max:1.8 (38G: 2.0); Standby ODU port insertion loss, dB max: 7.2 (38G:7.4) ODU port insertion loss, db max:3.8 (38G:4.0).

Symmetrical Hybrid Coupler (3dB)

with equal attenuation in both channels

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 6

Basic Knowledge

Trigger Conditions and Antenna Aligning


Alarms R_LOF,R_LOS,MW_LOF are the microwave link alarm. While aligning antennas, the microwave link is not stable, will create these alarms. In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off

the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on the standby IF ODU-PWR.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

Basic Knowledge

1+1 HSB/FD/SD Compare


Item Quantity of ODU Quantity of Antenna Quantity of Hybrid Coupler Quantity of Frequency Channel 2 1 1 1 HSB 2 1/2 1/0 2 FD 2 2 0 1 SD Notes
HSB/SD: main ODU type is same as standby. HSB/SD: Only configure main IF parameters. FD: Configure main and standby IF parameters respectively.

HSB Support HSM Support

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

CONTENT
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD

1+1 HSB Commissioning

1+1 HSB Commissioning Steps


Link 1+1 Configure Parameters Configure Turn off Standby IF ODU-PWR Switch

Align Antenna

Turn on Standby IF ODU-PWR Switch

1+1 Switch State and Test

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

1+1 HSB Commissioning

Link 1+1 Configure


To Next Page

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

1+1 HSB Commissioning

Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

1+1 HSB Commissioning

IP Parameters Configure

For 1+1 HSB, only configure main IF board parameters.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

1+1 HSB Commissioning

Query 1+1 HSB Switch State


Switch State

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 14

1+1 HSB Commissioning

1+1 Switch Control


Right Click

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

CONTENT
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD

1+1 FD Commissioning

1+1 FD Commissioning Steps


Link 1+1 Configure Parameters Configure Turn off Standby IF ODU-PWR Switch

Align Antenna

Turn on Standby IF ODU-PWR Switch

1+1 Switch State and Test

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 17

1+1 FD Commissioning

Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

1+1 FD Commissioning

IF Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

1+1 FD Commissioning

IF Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

CONTENT
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD

1+1 SD Commissioning

1+1 SD Commissioning Steps


Link 1+1 Configure IF Parameters Configure Turn off Standby IF ODU-PWR Switch Align main Antenna

Turn on Standby IF ODU-PWR Switch

Align Standby Antenna

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 22

1+1 SD Commissioning

1+1 Link Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

1+1 SD Commissioning

Parameters Configure

For 1+1 SD, only configure main IF board parameters.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

1+1 SD Commissioning

Turn off two side standby ODU's power, turn on two main ODU's power, firstly, align two main antennas.

: ODU Power on. X: ODU Power off.


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 25

1+1 SD Commissioning

Turn on local site standby ODU's power, keep opposite site main antenna fixed, align local standby antenna towards opposite main one.

: ODU Power on. X: ODU Power off.


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26

1+1 SD Commissioning

Turn on opposite standby ODU's power, keep local main antenna fixed, align opposite standby antenna towards local main one.

: ODU Power on. X: ODU Power off.


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27

Thank you
www.huawei.com