Académique Documents
Professionnel Documents
Culture Documents
F1 InterFreqLDHO CodeAdj BERateRed CSInterRatShouldBeLDHO NoAct InterFreqLDHO BERateRed NoAct NoAct NoAct TRUE ON 3 3 1 6 1
UCELLLDR:CELLID DLLDRFIRSTACTION DLLDRSECONDACTION DLLDRTHIRDACTION DLLDRFOURTHACTION DLLDRFIFTHACTION ULLDRFIRSTACTION ULLDRSECONDACTION ULLDRTHIRDACTION ULLDRFOURTHACTION ULLDRFIFTHACTION CODECONGSELINTERFREQHOIND GOLDUSERLOADCONTROLSWITCH MAXUSERNUMCODEADJ DLCSINTERRATSHOULDBEHOUENUM DLPSINTERRATSHOULDBEHOUENUM DLCSINTERRATSHOULDNOTHOUENUM DLPSINTERRATSHOULDNOTHOUENUM
LdbDRDOffsetHSDPA
F2 CodeAdj BERateRed InterFreqLDHO NoAct NoAct InterFreqLDHO BERateRed NoAct NoAct NoAct TRUE ON 3 3 1 6 1
Check FALSE FALSE FALSE FALSE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE
Parameter Name DL LDRfirst action DL LDRsecondaction DL LDRthird action DL LDRfourthaction DL LDRfifth action UL LDRfirst action UL LDRsecond action UL LDRthird action UL LDRfourth action UL LDRfifth action Code congestion select inter-freq indication Gold user load control switch Max user number of code adjust DL CS should be Ho user number DlPSInterRatShouldBeHOUeNum DL CS should not be Ho user number DL PS should not be HO user number
Recommanded values Be rate reduction CoAdj Interfreq NoAct NoAct BERateRed InterFreqLDHO NoAct NoAct NoAct
3 1 1
UCELLSELRESEL:CELLID IDLEQHYST2S CONNQHYST2S NONHCSIND QUALMEAS IDLEQHYST1S CONNQHYST1S TRESELECTIONS QQUALMIN QRXLEVMIN QRXLEVMINEXTSUP MAXALLOWEDULTXPOWER IDLESINTRASEARCH
UCELLSELRESEL:CELLID IDLEQHYST2S CONNQHYST2S NONHCSIND QUALMEAS IDLEQHYST1S CONNQHYST1S TRESELECTIONS QQUALMIN QRXLEVMIN QRXLEVMINEXTSUP MAXALLOWEDULTXPOWER IDLESINTRASEARCH
IDLESINTERSEARCH CONNSINTRASEARCH
0 4
IDLESINTERSEARCH CONNSINTRASEARCH
10 4
CONNSINTERSEARCH SSEARCHRAT SPEEDDEPENDENTSCALINGFACTOR INTERFREQTRESELSCALINGFACTOR INTERRATTRESELSCALINGFACTOR QHYST1SPCH QHYST1SFACH QHYST2SPCH QHYST2SFACH TRESELECTIONSPCH TRESELECTIONSFACH SPRIORITY THDPRIORITYSEARCH1 THDPRIORITYSEARCH2 THDSERVINGLOW
CONNSINTERSEARCH SSEARCHRAT SPEEDDEPENDENTSCALINGFACTOR INTERFREQTRESELSCALINGFACTOR INTERRATTRESELSCALINGFACTOR QHYST1SPCH QHYST1SFACH QHYST2SPCH QHYST2SFACH TRESELECTIONSPCH TRESELECTIONSFACH SPRIORITY THDPRIORITYSEARCH1 THDPRIORITYSEARCH2 THDSERVINGLOW
Check TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE
Parameter Name Hysteresis 2 for idle mode Hysteresis 2 for connect mode Non-HCS indicator Cell Sel-reselection quality measure Hysteresis 1 for idle mode Hysteresis 1 for connect mode Reselection delay time Min quality level Min RX Level Min Rx level Extend Support MaxAllowedUlTxPower Intra-freq cell reselection threshold for idle mode
Recommanded values 1 (2 dB) 1 (2 dB) NOT_CONFIGURED CPICH_ECNO 2 ( 4 dB) 2 ( 4 dB) 1 (1s) - 18 (-18dB) -53 ( -105 dBm) FALSE 24 5 (10 dB) For F1 cells : -5 (-10db) with SIB11ind = FALSE For F2 cells: 10 (20dB) with SIB11ind=True 5 (10 dB) For F1 cells : -5 (-10db) with SIB11ind = FALSE For F2 cells: 10 (20dB) with SIB11ind=True 1(2dB) 255 255 255 2 ( 4 dB) 2 ( 4 dB) 1 (2 dB) 1 (2 dB) 1 (1s) 1 (1s) 4 2 2 1
FALSE Inter-freq cell reselection threshold for idle mode TRUE Intra-freq cell reselection threshold for connect mode
TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE
Inter-freq cell reselection threshold for connect mode Inter-RAT cell reselection threshold SpeedDependentScalingFactor Inter-freqency scaling factor for reselection delay Inter-RAT scaling factor for reselection delay Hysteresis 1 for UE in CELL_PCH or URA_PCH state Hysteresis 1 for UE in CELL_FACH state Hysteresis 2 for UE in CELL_PCH or URA_PCH state Hysteresis 2 for UE in CELL_FACH state Reselection delay time for UE in PCH state Reselection delay time for UE in CELL_FACH state Absolute priority level of the serving cell RSCP threshold for low-prio-freq measurement initiation Ec/No threshold for low-prio-freq measurement initiation RSCP threshold for low-prio-freq reselection
F1 D3 6 D640 -16 60 4 5
F2 D3 6 D640 -14 60 4 5