UCELLLDR:CELLID DLLDRFIRSTACTION DLLDRSECONDACTION DLLDRTHIRDACTION DLLDRFOURTHACTION DLLDRFIFTHACTION ULLDRFIRSTACTION ULLDRSECONDACTION ULLDRTHIRDACTION ULLDRFOURTHACTION ULLDRFIFTHACTION CODECONGSELINTERFREQHOIND GOLDUSERLOADCONTROLSWITCH MAXUSERNUMCODEADJ DLCSINTERRATSHOULDBEHOUENUM

DLPSINTERRATSHOULDBEHOUENUM DLCSINTERRATSHOULDNOTHOUENUM DLPSINTERRATSHOULDNOTHOUENUM

F1 InterFreqLDHO CodeAdj BERateRed CSInterRatShouldBeLDHO NoAct InterFreqLDHO BERateRed NoAct NoAct NoAct TRUE ON 3 3 1 6 1

UCELLLDR:CELLID DLLDRFIRSTACTION DLLDRSECONDACTION DLLDRTHIRDACTION DLLDRFOURTHACTION DLLDRFIFTHACTION ULLDRFIRSTACTION ULLDRSECONDACTION ULLDRTHIRDACTION ULLDRFOURTHACTION ULLDRFIFTHACTION CODECONGSELINTERFREQHOIND GOLDUSERLOADCONTROLSWITCH MAXUSERNUMCODEADJ DLCSINTERRATSHOULDBEHOUENUM DLPSINTERRATSHOULDBEHOUENUM DLCSINTERRATSHOULDNOTHOUENUM DLPSINTERRATSHOULDNOTHOUENUM

LdbDRDOffsetHSDPA

F2 CodeAdj BERateRed InterFreqLDHO NoAct NoAct InterFreqLDHO BERateRed NoAct NoAct NoAct TRUE ON 3 3 1 6 1

Check FALSE FALSE FALSE FALSE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE

Parameter Name DL LDRfirst action DL LDRsecondaction DL LDRthird action DL LDRfourthaction DL LDRfifth action UL LDRfirst action UL LDRsecond action UL LDRthird action UL LDRfourth action UL LDRfifth action Code congestion select inter-freq indication Gold user load control switch Max user number of code adjust DL CS should be Ho user number DlPSInterRatShouldBeHOUeNum DL CS should not be Ho user number DL PS should not be HO user number

Recommanded values Be rate reduction CoAdj Interfreq NoAct NoAct BERateRed InterFreqLDHO NoAct NoAct NoAct

3 1 1

UCELLSELRESEL:CELLID IDLEQHYST2S CONNQHYST2S NONHCSIND QUALMEAS IDLEQHYST1S CONNQHYST1S TRESELECTIONS QQUALMIN QRXLEVMIN QRXLEVMINEXTSUP MAXALLOWEDULTXPOWER IDLESINTRASEARCH

F1 2 1 NOT_CONFIGURED CPICH_ECNO 4 2 1 -18 -53 FALSE 24 5

UCELLSELRESEL:CELLID IDLEQHYST2S CONNQHYST2S NONHCSIND QUALMEAS IDLEQHYST1S CONNQHYST1S TRESELECTIONS QQUALMIN QRXLEVMIN QRXLEVMINEXTSUP MAXALLOWEDULTXPOWER IDLESINTRASEARCH

F2 2 1 NOT_CONFIGURED CPICH_ECNO 4 2 1 -18 -53 FALSE 24 5

IDLESINTERSEARCH CONNSINTRASEARCH

0 4

IDLESINTERSEARCH CONNSINTRASEARCH

10 4

CONNSINTERSEARCH SSEARCHRAT SPEEDDEPENDENTSCALINGFACTOR INTERFREQTRESELSCALINGFACTOR INTERRATTRESELSCALINGFACTOR QHYST1SPCH QHYST1SFACH QHYST2SPCH QHYST2SFACH TRESELECTIONSPCH TRESELECTIONSFACH SPRIORITY THDPRIORITYSEARCH1 THDPRIORITYSEARCH2 THDSERVINGLOW

4 2 255 255 255 255 255 255 255 255 255 4 2 2 1

CONNSINTERSEARCH SSEARCHRAT SPEEDDEPENDENTSCALINGFACTOR INTERFREQTRESELSCALINGFACTOR INTERRATTRESELSCALINGFACTOR QHYST1SPCH QHYST1SFACH QHYST2SPCH QHYST2SFACH TRESELECTIONSPCH TRESELECTIONSFACH SPRIORITY THDPRIORITYSEARCH1 THDPRIORITYSEARCH2 THDSERVINGLOW

4 2 255 255 255 255 255 255 255 255 255 4 2 2 1

Check TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE

Parameter Name Hysteresis 2 for idle mode Hysteresis 2 for connect mode Non-HCS indicator Cell Sel-reselection quality measure Hysteresis 1 for idle mode Hysteresis 1 for connect mode Reselection delay time Min quality level Min RX Level Min Rx level Extend Support MaxAllowedUlTxPower Intra-freq cell reselection threshold for idle mode

Recommanded values 1 (2 dB) 1 (2 dB) NOT_CONFIGURED CPICH_ECNO 2 ( 4 dB) 2 ( 4 dB) 1 (1s) - 18 (-18dB) -53 ( -105 dBm) FALSE 24 5 (10 dB) For F1 cells : -5 (-10db) with SIB11ind = FALSE For F2 cells: 10 (20dB) with SIB11ind=True 5 (10 dB) For F1 cells : -5 (-10db) with SIB11ind = FALSE For F2 cells: 10 (20dB) with SIB11ind=True 1(2dB) 255 255 255 2 ( 4 dB) 2 ( 4 dB) 1 (2 dB) 1 (2 dB) 1 (1s) 1 (1s) 4 2 2 1

FALSE Inter-freq cell reselection threshold for idle mode TRUE Intra-freq cell reselection threshold for connect mode

TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE

Inter-freq cell reselection threshold for connect mode Inter-RAT cell reselection threshold SpeedDependentScalingFactor Inter-freqency scaling factor for reselection delay Inter-RAT scaling factor for reselection delay Hysteresis 1 for UE in CELL_PCH or URA_PCH state Hysteresis 1 for UE in CELL_FACH state Hysteresis 2 for UE in CELL_PCH or URA_PCH state Hysteresis 2 for UE in CELL_FACH state Reselection delay time for UE in PCH state Reselection delay time for UE in CELL_FACH state Absolute priority level of the serving cell RSCP threshold for low-prio-freq measurement initiation Ec/No threshold for low-prio-freq measurement initiation RSCP threshold for low-prio-freq reselection

UCELLHOCOMM:CELLID INTERFREQRATSWITCH COEXISTMEASTHDCHOICE CSSERVICEHOSWITCH

F1 INTERFREQ COEXIST_MEAS_THD_CHOICE_INTERFREQ OFF

UCELLHOCOMM:CELLID INTERFREQRATSWITCH COEXISTMEASTHDCHOICE CSSERVICEHOSWITCH

F2 SIMINTERFREQRAT COEXIST_MEAS_THD_CHOICE_INTERFREQ OFF

Check FALSE TRUE TRUE

Recommanded values SIMINTERFREQRAT(inter-frequency and inter-RAT handover) COEXIST_MEAS_THD_CHOICE_INTERFREQ OFF

UCELLINTERFREQHONCOV:CELLID INTERFREQFILTERCOEF HYSTFOR2C TRIGTIME2C INTERFREQCOVHOTHDECN0 INTERFREQMEASTIME PERIODFOR2C AMNTOFRPT2C

F1 D3 6 D640 -16 60 4 5

UCELLINTERFREQHONCOV:CELLID INTERFREQFILTERCOEF HYSTFOR2C TRIGTIME2C INTERFREQCOVHOTHDECN0 INTERFREQMEASTIME PERIODFOR2C AMNTOFRPT2C

F2 D3 6 D640 -14 60 4 5

Check TRUE TRUE TRUE FALSE TRUE TRUE TRUE

Recommanded values D3 6 D640 -16 15 (15s) 4 (2s) 1