TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
SSM ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE :

SYAM

Taufiq

Ir. SHAN

9th.May 2002

1.0) Design Criteria The work design s base on code BS 5950 for steel structure and BS 8110 for concrete structure at foundation part. The safe working load are basically as normal factor such as 1.75. In this work design the stiffiners are using by using welding connection and the main leg is 150 x 150 x 16 EA. The Table 1.1 is shown the grade are using. Materials Grade 1.1) Design Data a) Compression / Uplift = b) Tower Weight = Actual = c) Lateral Load = 1115 KN 340 KN 775 KN 102 KN 775.00 KN Steel S275 Bolt/Nuts Concrete 4.6 Electrode 35 Strength (Pw) 220

25

102 KN

300 mm

450

TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
HLA ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE:

SYAM

Taufiq

Ir. SHAN

9th.May 2002

A) Directional Method Clause 6.8.7.3 Pl = pw x a Pw Fillet Weld Where , a = 0.7 s a Therefore, Pl = = 5.6 mm 1232 N/mm = = 220 N/mm2 8 mm

K K

= 1.25 [(1.5/(1 + Cos2(O))] = 1.25 KPI N/mm 1540 N/mm 102 x 1.75 / 2 (200) 446.25 N/mm N/mm For Degree O = 45 degree

PT = = FL = = FT = =

1959.40 x 1000/2(750) N/mm 1306.3 N/mm

Therefore, (FL/PL)^2 0.1 + + 0.9 (FT/PT)^2 0.7 < < < 1 1 1 O.K ! Satisfy

750 mm

200 mm

Stiffeners Coclusion is adopt fillet weld size 8 mm is O.K !

TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
SSM ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE:

Syam Mat Yusuf

Mohd Taufiq Ahmad

Ir. SHAN

9th.May 2002

B) Area of Base Plate Area, A = Compression 0.4fcu = = = 775 x 1.75 x 1000 0.4 x 25 135625 mm2 368 mm x 368 mm

Therefore, adopt size 450mm x 450mm is satisfy . O.K !

C) HOLDING DOWN BOLT

Pt

0.8ptA

pt A

= = =

240 N/mm2 From Table 34 Bs 5950 d^2/4 804 mm2 where, d = 32 mm

= =

154436 N 154.436 KN

For Tower one leg, use 8 M32 Therefore, Fv = = 775 x 1.75/8 169.531 KN

>

154.44 KN

FAIL

If by using a factor of 1.0 according to cluase 2.4 nad Table 2 (ULS) bS 5950 The force per bolt = = 96.875 KN 96.875 Kn < 154.44 KN O.K

So, by adopt the 8 bolt with (M32) per leg of tower, the HDB is O.K !

TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
SSM ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE:

Syam Mat Yusuf

Mohd Taufiq Ahmad

Ir. Shan Suleiman

9th.May 2002

TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
SSM ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE:

SYAM

Ir. SHAN

Ir. SHAN

TAJUK : BASE PLATE DESIGN TOWER TRANSMISSION LINES-CELCOM PERKARA : BS 5950 STEEL WORK DESIGN

PROJECT NO:

SHEET NO:

CALCULATION NO:
SSM ASO. SDN. BHD Consulting Engineer

DESIGNED BY:

CHECKED BY:

APPROVED BY:

DATE:

SYAM

Ir. SHAN

Ir. SHAN

Vous aimerez peut-être aussi