Vous êtes sur la page 1sur 2

SYMBOLS

( DATE)

NOTES:
PERMANENT SURVEY MARK SURVEY STATION S&C PIT S&C RELAY STAUNCHION RAILWAY OVERHEAD STRUCTURE GUY LIGHT POLE POWER POLE ELECTRICITY PIT
1.3 1.4 1.5

1.

INSTALLATION & REFERENCE UNLESS NOTED OTHERWISE, INSTALLATION, SIGNAGE, UNSPECIFIED DIMENSIONS & ASSOCIATED WORKS SHALL BE IN ACCORDANCE WITH DRAWINGS / REFERENCES AS BELOW OR WITH SITE SPECIFIC DRAWINGS : 1.1 VICTORIAN RAIL INDUSTRY OPERATORS GROUP STANDARDS - VEHICLE CROSSINGS
1.2 MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES RAILWAY CROSSINGS KERBS OPEN DRAIN & TRACK FORMATION OUTSIDE CROSSING SIGNS SHOULD BE TURNED ABOUT 5 AWAY FROM THE NORMAL TO THE HEADLIGHT BEAM 1.6 1.7 1.8 1.9 FLASHING LIGHT LAYOUT FLASHING LIGHTS & RX5 ASSEMBLY (R6-24 SIGNS) CANTILEVER FLASHING LIGHTS ASSEMBLY (R6-24 SIGNS) BOOM BARRIER ASSEMBLY (R6-24 SIGNS) STD_R0007 STD_G0022 STD_G0023 STD_G0021 VICROADS SD 2001 STD_R0004 AS 1742.7 SECTION B3 AS1742.7

SIGNAGE LEGEND

R6-25

R6-25

R A I L

R6-24

G N I S S W O A R Y C

W7-2-1

VRIOGS 003.3

STOP
R6-9
ON RED

G9-48 G9-67-2

SIGNAL

PREPARE TO STOP

( SI GNATURE)

FLASHING LIGHTS
IRJ

INSULATED RAIL JOINT SIGNAL TELECOM POLE TELECOM PIT TELECOM PILLAR G & F VALVE STOP VALVE FIRE PLUG FIRE HYDRANT SIDE ENTRY PIT

W8-5

RX-1

RX-2

RX-5

RX-11

D4-2-1

1.10 1.11 1.12 1.13

FLASHING LIGHTS AND RX - 5 ASSEMBLY (R6-25 SIGNS) CANTILEVER FLASHING LIGHTS ASSEMBLY (R6 - 25 SIGNS) BOOM BARRIER ASSEMBLY (R6 - 25 SIGNS) STEPS, RAMP & WALKWAY GENERAL REQUIREMENT FOR ACCESS & MOBILITY.

STD_G0218 STD_G0219 STD_G0217 AS1428.1

D4-1-3

D4-1-2

D4-V103

D4-6 W8-22
R1-1 R1-2 R4-1

( BL OCK L ETTERS)

GRATED PIT DRAINAGE PIT

1.14

FIXED PLATFORMS, WALKWAYS, STAIRWAYS & LADDERS DESIGN, CONSTRUCTION & INSTALLATION.

AS1657

1.15

PTCV HEAVY RAIL TRACK CONSTRUCTION STANDARDS STRUCTURE GAUGE ENVELOPES - MINIMUM CLEARANCES FOR INFRASTRUCTURE ADJACENT TO THE RAILWAY

PART C - REV. 1.3 VRIOGS 001

SEWER PIT
1.16

TREE
1.17

STANDARD FOR SIGNALLING DESIGN AND DOCUMENTATION SPECIFICATION FOR SIGNALLING SUPPLY, CONSTRUCTION AND INSTALLATION

VRIOGS 012.1 VRIOGS 012.2

SERVICES LEGEND
GUARD FENCE FENCE ON BOUNDARY

1.18

R2-3(L)
STD_C0003 STD_C0004 STD_C0007 STD_G0025 STD_G0074 STD_C0007

R7-4

1.19 1.20 1.21 1.22 1.23 2.

PASSIVE LEVEL CROSSING GENERAL ARRANGEMENT ACTIVE LEVEL CROSSING GENERAL ARRANGEMENT TRACK AND ROAD PAVEMENT THROUGH LEVEL CROSSINGS RX - 9 ASSEMBLY DETAILS FOUNDATION SIGNAL MASTS

Ce r t i f i e d By :

FENCE COMPRESSED AIR - ABOVE GROUND COMPRESSED AIR - UNDER GROUND DRAIN - ABOVE GROUND DRAIN - UNDER GROUND ELECRICITY - ABOVE GROUND ELECTRICITY - UNDER GROUND LOW VOLTAGE ELECRICITY - A. GROUND LOW VOLTAGE ELECTRICITY - U. GROUND HIGH VOLTAGE ELECRICITY - A. GROUND HIGH VOLTAGE ELECTRICITY - U. GROUND FUEL - ABOVE GROUND FUEL - UNDER GROUND GAS - ABOVE GROUND GAS - UNDER GROUND HP GAS - ABOVE GROUND HP GAS - UNDER GROUND OPTIC FIBRE - ABOVE GROUND OPTIC FIBRE - UNDER GROUND HP OIL - ABOVE GROUND HP OIL - UNDER GROUND PIPELINE - ABOVE GROUND PIPELINE - UNDER GROUND SERVICE DUCT SEWER - ABOVE GROUND SEWER - UNDER GROUND SIGNALS & COMMS SERVICE LINE - A.G. SIGNALS & COMMS SERVICE LINE - U.G. SIGNAL RODING ABOVE GROUND TELSTRA - LINE ABOVE GROUND
$ NAM E$

G9-32

RAILWAY

CROSSING
D4-3(L) D4-3(R)

G9-33

G9-32 G9-33

SIGNAL EQUIPMENT

RAILWAY CROSSING

RAILWAY CROSSING
D4-3(L) D4-3(R)

G9-32 G9-33

PREFERRED RX-9 ASSEMBLY

MODIFIED RX-9 ASSEMBLIES

W8-3(L)

W8-3(R)

W7-7(R)

W7-7(L)

W7-9(L)

W7-9(R)

W7-12

W7-4

W1-3

W2-14(L)

W2-14(R)

W2-9(L)

W2-9(R)

W1-4

TELSTRA - UNDER GROUND SIGNALS TROUGHING - ABOVE GROUND SIGNALS TROUGHING - UNDER GROUND UNIDENTIFIED SERVICE WATER SUPPLY - ABOVE GROUND WATER SUPPLY - UNDER GROUND OPERATORS AUTHORISED BY DATE

W7-8

W2-3

W6-1
Consultant

METRO

R7-1-4

W3-2

W3-1

W6-3

V/LINE

Ahmed Dwidar Shane Cooper


Drawn By B.C. Checked By A.C.

04/05/12 13/06/12
Designed By B.C. Ind. Review

coffey
Franchisee / Lessee
State Government

rail

This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.

$ TI M E$

RAILWAY TRACK AND CIVIL STANDARD DRAWING


LEVEL CROSSINGS GENERAL NOTES & SPECIFICATIONS SHEET 1
Up Location East. North. ID# Down Location East. North. ID# Scale AS SHOWN Sheet Size A3 Datum File Name Sheet No. In Serv. STD_C0002.dgn

Approved H.R.E. Drawing Number

Approval Date 16/12/11 Revision

01 of 02

$ DATE$

Revised By

In Serv

Rev.

Date

Description

Designed Checked Ind. Rev. Approv.

Department of

<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0016, STD_C0011, STD_C0013, STD_C0014, 117/2000 > $FILE$

Transport

This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.

STD_C0002

( DATE)

LINE TYPE

USE TWO-LANE TWO-WAY (NORMAL) 3m

PATTERN AND DIMENSIONS 9m 3m

TRAFFIC ENG. MANUAL VOL 2 REFER SECTION 100 WIDE

LINE TYPE

USE

PATTERN AND DIMENSIONS 600 600600 600 600600 600 600 600 600 400 WIDE

TRAFFIC ENG. MANUAL VOL 2 REFER SECTION 150 WIDE 150 WIDE 17.1

AT STOP SIGN (STOP LINE) 300 WIDE CONTROLLED AT GIVE WAY SIGN (HOLDING LINE) AT ROUNDABOUT SIGN (HOLDING LINE) 300 WIDE

SEPERATION LINE BETWEEN OPPOSING REVERSIBLE LANES TRAFFIC FLOWS 6m 6m 6m 100 WIDE 16.1

INTERSECTION (STATCON)

9m
( SI GNATURE)

1m

9m

100 WIDE SIGNALISED INTERSECTION 100 WIDE STOP LINE AND MIDBLOCK PEDESTRIAN OPERATED SIGNALS SIGNALISED INTERSECTIONS AND MIDBLOCK PEDESTRIAN OPERATED SIGNALS 150 WIDE 17.3 600 WIDE 17.2

SPECIAL USE 9m STANDARD LANE LINES - INCLUDING FREEWAYS SPECIAL USE: MULTI-LANE ROUNDABOUT PART TIME SPECIAL PURPOSE LANE LINE BETWEEN TRAFFIC FLOWS IN SAME CONTINUOUS LINES ON ARTERIAL AND LOCAL ROADS FULL-TIME COMMUTER (e.g. BUS/BICYCLE) CONTINUOUS LINES ON FREEWAYS PEDESTRIAN RURAL FREEWAY URBAN FREEWAY 3m 3m 9m 9m 3m 3m 9m 9m 3m 3m RRPM EVERY 2nd GAP (24m) RRPM EVERY GAP (12m) CROSSING (ZEBRA) 150 WIDE 100 WIDE 16.2 SCHOOL OR CHILDRENS CROSSING 3m 9m 3m 100 WIDE PEDESTRIAN CROSSWALK 9m 3m 9m 100 WIDE 3m 9m

STOP LINE WALK LINE

600 WIDE 150 WIDE


2 . 5 TO 4 . 5 m

17.2 17.3

( BL OCK L ETTERS)

DIRECTION

CROSSWALK MARKINGS
600 600

17.3

WHITE STRIPES

Ce r t i f i e d By :

ONE-WAY 3m 9m 3m

100 WIDE

SOLID 100 WIDE

BARRIER LINE

TWO-WAY

100 WIDE

16.3

UNBROKEN TURN LINE FOR NORMAL USE

SINGLE CONTINUOUS SEPARATION LINE

100 OR 150 WIDE SOLID 100 WIDE YELLOW

FAIRWAY LINE

FULL OR PART TIME TRAM LANE LINES BROKEN TRAM LANE LINES 6m YELLOW 6m 6m YELLOW

100 WIDE 16.6 100 WIDE 100 WIDE 100 WIDE 150 WIDE RAILWAY
50

TURN LINE

BROKEN TURN LINE TO SECOND TURN POINT (E.G. SERVICE ROAD) OR TO DELINEATE MULTIPLE LEFT TURN LANE

6 0 0L I N E BROKEN 100 WIDE

17.3
6 0 0G A P

NORMAL USE (WHITE) PARKING CONTROL (YELLOW) EDGE LINE FREEWAY, M ROADS, A ROADS IN RURAL AREAS, SPECIAL USES

16.4 AT STOP SIGN, FLASHING LIGHTS AND GATE CONTROL CROSSING 17.2.3 AT GIVE WAY SIGN
600 600

600 WIDE

600 WIDE

8 mm HIGH BARS PROFILED EDGE LINE SAFETY INITIATIVE SUBJECT


1 5 0

16.4.4
200 GAP

TO WARRANTS

NOTES:
1. REFER TO VICROADS TRAFFIC ENGINEERING MANUAL VOLUME 2 SIGNS AND MARKINGS. 2. FOR "RAIL X" LINE MARKING ON MAIN ROAD APPROACHES REFER TO AS1742.7 SECTION 3 FOR DETAILS

$ NAM E$

"STANDARD" TYPE CONTINUITY LINE FREEWAY AND SPECIAL USE "STATCON" TYPE

1m 1m

3m 3m

1m 1m

100 WIDE 150 WIDE 150 WIDE 16.5

3. FOR "KEEP CLEAR" LINE MARKING DETAILS REFER TO AS1742.2.

600600 600

Consultant
$ TI M E$

coffey
Franchisee / Lessee
State Government

rail

This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.

RAILWAY TRACK AND CIVIL STANDARD DRAWING


LEVEL CROSSINGS LINE MARKING, PATTERN AND DIMENSIONS
Up Location East. North. ID# Down Location East. North. ID# Scale AS SHOWN Sheet Size A3 Datum File Name Sheet No. In Serv. STD_C0002.dgn

Drawn By B.C. Checked By A.C. Approved H.R.E. Drawing Number

Designed By B.C. Ind. Review

Approval Date 16/12/11 Revision

02 of 02

$ DATE$

Revised By

In Serv

Rev.

Date

Description

Designed Checked Ind. Rev. Approv.

Department of

<REDRAWN & REVISED. SUPERSEDES PLAN No.. STD_R0016> $FILE$

Transport

This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.

STD_C0002

Vous aimerez peut-être aussi