Vous êtes sur la page 1sur 67

System

CONFIGURATION RULES FOR


SYSTEM CABLING BS-240/241

A30808-X3247-G900-01-7618

A30808-X3247-G900-01-7618

The document comprises 67 pages.


All pages have issue no 01.

A30808-X3247-G900-01-7618

Table of Contents
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7

INTRODUCTION................................................................................................................ 1-5
General.......................................................................................................................... 1-5
Rack / Shelter Cabling................................................................................................... 1-5
External Cabling ............................................................................................................ 1-5
Terminator ..................................................................................................................... 1-5
Slot Numbering.............................................................................................................. 1-6
Functionality of cables................................................................................................... 1-7
Table of Variants ........................................................................................................... 1-8

RF-CABLING ..................................................................................................................... 2-9


2.1 BS240/241 with DUAMCO ............................................................................................ 2-9
2.1.1 Survey of Variants .................................................................................................... 2-9
2.1.1.1 DUAMCO 2:2 , 1Cell (X,0,0) ............................................................................ 2-10
2.1.1.1.1 Configuration............................................................................................... 2-11
2.1.1.2 DUAMCO 4:2 , 1 Cell (X, 0, 0) ......................................................................... 2-12
2.1.1.2.1 Configuration............................................................................................... 2-13
2.1.1.3 DUAMCO 8:2 , 1Cell (X,0,0) ............................................................................ 2-14
2.1.1.3.1 Configuration............................................................................................... 2-15
2.1.1.4 DUAMCO 2:2 , 2Cell (X,X,0)............................................................................ 2-16
2.1.1.4.1 Configuration............................................................................................... 2-17
2.1.1.5 DUAMCO 4:2 , 2Cell (X,X,0)............................................................................ 2-18
2.1.1.5.1 Configuration............................................................................................... 2-19
2.1.1.6 DUAMCO 2:2 / 4:2 , 2Cell (X,X,0).................................................................... 2-20
2.1.1.6.1 Configuration............................................................................................... 2-21
2.1.1.7 DUAMCO 2:2 , 3Cell (X,X,X) ........................................................................... 2-22
2.1.1.7.1 Configuration............................................................................................... 2-23
2.1.1.8 2x DUAMCO 2:2 , DUAMCO 4:2 , 3Cell (X,X,X) ............................................. 2-24
2.1.1.8.1 Configuration............................................................................................... 2-25
2.1.2 Description of Variants ........................................................................................... 2-26
2.1.2.1 TX-Path ............................................................................................................ 2-26
2.1.2.2 RX-Path............................................................................................................ 2-27
2.2 BS240/241 with FICOM and DIAMCO ........................................................................ 2-33
2.2.1 Survey of Variants .................................................................................................. 2-33
2.2.1.1 FICOM , 1Cell (X,0,0) ...................................................................................... 2-34
2.2.1.1.1 Configuration............................................................................................... 2-35
2.2.1.2 FICOM , 2Cell (max. 4,4,0) .............................................................................. 2-36
2.2.1.2.1 Configuration............................................................................................... 2-37
2.2.1.3 FICOM , 2Cell (max. 2,6,0) .............................................................................. 2-38
2.2.1.3.1 Configuration............................................................................................... 2-39
2.2.2 Description of Variants ........................................................................................... 2-39
2.2.2.1 TX-Path ............................................................................................................ 2-39
2.2.2.2 RX-Path............................................................................................................ 2-40

INTERRACK / INTERSHELTER CABLING .................................................................... 3-41


3.1 Interrack Cabling ......................................................................................................... 3-41
3.1.1 DC Cabling ............................................................................................................. 3-41
3.1.2 Battery Cabling....................................................................................................... 3-43
3.1.3 CAN-Bus Cabling ................................................................................................... 3-45
3.1.4 SELIC-Cabling........................................................................................................ 3-47
3.1.5 Grounding............................................................................................................... 3-49
3.2 Intershelter Cabling ..................................................................................................... 3-50
3.2.1 AC Cabling ............................................................................................................. 3-50
3.2.2 DC Cabling ............................................................................................................. 3-52
3.2.3 Battery Cabling....................................................................................................... 3-54
3.2.4 CAN-Bus Cabling ................................................................................................... 3-56
3.2.5 SELIC-Cabling........................................................................................................ 3-58
3.2.6 Grounding............................................................................................................... 3-60

4
4.1
4.2

HPDU ............................................................................................................................... 4-61


Mounting Positions Rack............................................................................................. 4-61
HPDU Cabling Rack.................................................................................................... 4-62
A30808-X3247-G900-01-7618

4.3
4.4

Mounting Positions Shelter ......................................................................................... 4-63


HPDU Cabling Shelter................................................................................................. 4-64

5.1
5.2

RF-CABLING RACK / SHELTER TO RACK / SHELTER .............................................. 5-65


Cell spread over 2 Racks / Shelter.............................................................................. 5-65
Cabling ........................................................................................................................ 5-65

LIST OF ABBREVIATIONS............................................................................................. 6-66

A30808-X3247-G900-01-7618

1
1.1

INTRODUCTION
General

This document informs about variable cable connections depending on BTSplus configuration which
are not fix installed in the factory.
The document describes the Rack/Shelter internal RF-cabling according to the several cell
configuration and Antenna combining systems, further possible RF- and battery cabling
configurations from one to another Rack/Shelter .
The document gives rules how to assemble standard configurations for all combining systems. Also
special configurations can be assembled according to this rules.
For the running of system cables, done by service or factory, please refer to document System
Cabling BTSplus, F42088-A1080-A081.
The connections are documented by cabling variants.
The statements in this document are based on "Specification , Configuration Rules for BTSplus,
A30862-X1001-A530-*-7659".

1.2

Rack / Shelter Cabling

The Rack/Shelter cabling means all cables which are component of part lists and fix installed in the
factory. The Rack / Shelter Cabling is not part of this document.

1.3

External Cabling

External cabling means all cables which are connected from external equipment (antenna, AC-main
supply, external battery) to the Rack/Shelter interfaces. The External Cabling is not part of this
document

1.4

Terminator

Terminators are necessary for unused RF-input or output connectors of BTSplus RF-equipment .
The following terminators are used:
C39195-Z80-C30
SMA
C39195-Z80-C31
SMC
DUAMCO:
If no RX and RXCA connector is used, the connectors need not to be terminated.
If at least one RX or RXCA connector is used, all unused RX# and RXCA# connectors of a module
have to be terminated with a 50 ohms load resistor. The RXCA# output has a SMA connector, the
RX# outputs have SMC connectors.
In normal operation all open TX# inputs of a DUAMCO need not to be terminated.
DIAMCO:
If no RX and RXCA connector is used, the connectors need not to be terminated.
If at least one RX or RXCA connector is used, all unused RX# and RXCA# connectors of a module
have to be terminated with a 50 ohms load resistor.
FICOM:
In normal operation all open TX connectors need not to be terminated.
An open expansion connector RF EXP of a FICOM module has to be terminated with the terminator
delivered with the FICOM base module

A30808-X3247-G900-01-7618

1-5

1.5

Slot Numbering

ACOM ACOM ACOM ACOM


#0
#1
#2
#3

CU
#3

MUCO # 1

CU
#2

MUCO # 0

CU
#2
CU
#6

CU
#7

CU
#3

MUCO # 1

CU
#1

MUCO # 0

CU
#0

CORE # 0
CORE # 1
CORE # 2
CORE # 2

For an optimal System Cabling the CU and ACOM slots are realated to each other. The following
figure shows the assignment of ACOM and CU in one Base Rack and one Base Shelter.
The assigment of CU and ACOM of the Extension Rack and Shelter are equivalent to its Base Rack /
Shelter.

CU
#4

CU
#5

CU
#6

CU
#7

CU
#0

CU
#1

CORE # 0
CORE # 1
CORE # 2
CORE # 2

ACOM ACOM ACOM ACOM


#0
#1
#2
#3

CU
#4

CU
#5

Plinth

Rack 240 (Base)

1-6

A30808-X3247-G900-01-7618

Shelter 241 (Base)

1.6

Functionality of cables

Here the functionality of the required system cables are given.


System Cabling

Code Number

Cable Drawing

Cable Type

SMC, 90, m

DUAMCO 0/3
CU 0/1/4/5

C39195-Z80-C113
1600mm

DUAMCO 1/2 CU 2/3/6/7

C39195-Z80-C114
950mm

FICOM CU 0/1/4/5

C39195-Z80-C115
1400mm

DIAMCO CU 0/1/2/3/6/7

C39195-Z80-C116
600mm

SMC, 90, m

Semi-rigid
.086 AI

RX-Path
SMA, 90, m

SMA, 90, m

Semi-rigid
.141 AI

TX-Path

SMA, 90, m

SMA, 90, m

Semi-rigid
.141 AI

TX-Path

SMC, 90, m

SMC, 90, m

Semi-rigid
.086 AI

RX-Path
SMC, 90, m

DIAMCO CU 4/5

C39195-Z80-C117
750mm

DUAMCO 1/2 CU 2/3/6/7

C39195-Z80-C118
1250mm

SMC, 90, m

Semi-rigid
.086 AI

RX-Path

SMC, 90, m

SMC, 90, m

Semi-rigid
.086 AI

RX-Path

FICOM CU 2/3/6/7

C39195-Z80-C160
1250mm

SMA, 90, m

SMA, 90, m

Semi-rigid
.141 AI

TX-Path
SMA, 90, m

DUAMCO 0/3 CU 0/1/4/5

C39195-Z80-C160
1250mm

HPDU (Shelter)DIAMCO

C39195-Z80-C175
800mm

HPDU (Rack)DIAMCO

C39195-Z80-C174
1250mm

HPDU ACOM
(Rack)

C39195-Z80-C173
400mm

HPDU ACOM
(Shelter)

C39195-Z80-C172
800mm

DIAMCO
(Rack/Shelter 0)DIAMCO
(Rack/Shelter 1)

C39195-Z80-C176
2700mm

SMA, 90, m

Semi-rigid
.141 AI

TX-Path

SMA, 90, m

HPDU

N-Con., 90, m

RX-Path

SMA, 90, m

HPDU

DIAMCO

Semi-rigid
.141 AI

N-Con. , 90, m

RX-Path

DIAMCO

7-16, 90, m

7-16, 90, m

Semi-rigid
.141 Al

Jumper

TX-Path

7-16, 90, m

7-16, 90, m

Jumper

TX-Path

SMA, 90, m

N-Con. , 90, m

Cascading

A30808-X3247-G900-01-7618

Coax
flexible

1-7

1.7

Table of Variants

Variants (VAR)
101 - 104
201, 202, 205, 206
217, 218, 221, 222
301, 302, 309, 310
001, 002
011, 012
031, 032
105 - 108
203, 204, 207, 208
219, 220, 223, 224
303, 304, 311, 312
003, 004
013, 014
033, 034
109 - 112
209, 210, 213, 214
225, 226, 229, 230
305, 306, 313, 314
005, 006
015, 016
023, 024, 035, 036
113 - 116
211, 212, 215, 216
227, 228, 231, 232
307, 308, 315, 316
007, 008
017, 018
025, 026, 037, 038
501-513
514-518
521-531
401,402,407,408
403-406
600
601
602
603
700

1-8

from

to

path

Cable Code No.


C39195-Z80-

DUAMCO 0

CU 0/1

RX

C113

DUAMCO 0

CU 0/1

TX

C160

DUAMCO 1

CU 2/3

RX

C118

DUAMCO 1

CU 2/3

TX

C114

DUAMCO 2

CU 6/7

RX

C118

DUAMCO 2

CU 6/7

TX

C114

DUAMCO 3

CU 4/5

RX

C113

DUAMCO 3

CU 4/5

TX

C160

DIAMCO 0
DIAMCO 0
DIAMCO 1
FICOM
FICOM
HPDU (Rack)
HPDU (Rack)
HPDU (Shelter)
HPDU (Shelter)
DIAMCO Rack 0

CU 0/1,2/3,6/7
CU 4/5
CU 2/3,4/5,6/7
CU 0/1,4/5
CU 2/3,6/7
DIAMCO (Rack)
FICOM (Rack)
DIAMCO (Shelter)
FICOM (Shelter)
DIAMCO Rack 1

RX
RX
RX
TX
TX
RX
TX
RX
TX

C116
C117
C116
C115
C118
C174
C173
C175
C172
C176

A30808-X3247-G900-01-7618

2
2.1

RF-CABLING
BS240/241 with DUAMCO

2.1.1 Survey of Variants


Here some variants of system cabling with DUAMCO are given.

A30808-X3247-G900-01-7618

2-9

2.1.1.1 DUAMCO 2:2 , 1Cell (X,0,0)

RX
RX div

DUAMCO 1
2:2

107

TX 0

111
112

RX
RX div

TX 0

007

008

SLOT 3

Module 0

TX 0

115
116

RX

TX 0

A30808-X3247-G900-01-7618

Module 1

RX 1

RX div

2-10

CU 4

RX
RX div

CU 5

Module 0

114

RX 0

Module 1

SLOT 3

RX 1

113

Carrier 7

DUAMCO 3
2:2

DUAMCO 3
2:2
RX 0

Carrier 6

006

TX 0

Module 0

005

Carrier 8

RX 1

RX
RX div

CU 6

Module 1

RX 0

110

CU 7

Module 0

SLOT 2

RX 1

109

Carrier 5

DUAMCO 2
2:2

DUAMCO 2
2:2
RX 0

Carrier 4

RX
RX div

Module 1

108

Module 1

RX 1

Carrier 3

004

TX 0

Module 0

003

SLOT 1

Module 0

RX div

RX 0

Module 1

SLOT 1

RX
106

CU 2

105

CU 3

DUAMCO 1
2:2

RX 0
RX 1

TX 0

Module 1

Module 1

104

Logical numbering of Carrier (Cell 0)

103
RX 0
RX 1

Carrier 1

002

TX 0

Carrier 2

001

Module 0

RX div

SLOT 2

Module 0

SLOT 0

RX 1

RX
102

SLOT 0

101
RX 0

CU 0

DUAMCO 0
2:2

CU 1

DUAMCO 0
2:2

2.1.1.1.1 Configuration

No.
of
cells

No. of
Carrier

No. of Carriers in
each cell
0
1
2

1
1
1
1
1

1
2
3
4
5

1
2
3
4
5

0
0
0
0
0

0
0
0
0
0

Variants RX

Variants TX

101,103
101,103,102,104
101,103,102,104,105,107
101,103,102,104,105,107,106,108
101,103,102,104,105,107,106,108,109,
111
101,103,102,104,105,107,106,108,109,
111,110,112
101,103,102,104,105,107,106,108,109,
111,110,112,113,115
101,103,102,104,105,107,106,108,109,
111,110,112,113,115,114,116

001
001,002
001,002,003
001,002,003,004
001,002,003,004,
005
001,002,003,004,
005,006
001,002,003,004,
005,006,007
001,002,003,004,
005,006,007,008

A30808-X3247-G900-01-7618

2-11

2.1.1.2 DUAMCO 4:2 , 1 Cell (X, 0, 0)

207

RX 1

013

014

RX 2
208

RX
RX div

TX 1

(SLOT 2)

(SLOT 2)

(SLOT 1)

(SLOT 1)

RX 3

TX 0

Module 1

RX 0
RX 1

RX
215

RX div

RX 2
RX 3

216

RX
RX div

017

018

A30808-X3247-G900-01-7618

TX 1

TX 0

TX 1

Car. 6

CU 6

016

Module 0

RX
RX div

Car. 7

214

Car. 8

212

TX 0

SLOT 3

RX 3

211

015

Module 1

RX 2

RX
RX div

CU 7

213

RX 1 210

CU 4

209

CU 5

SLOT 3

Module 0

RX 0

Car. 5

DUAMCO 3
4:2

DUAMCO 3
4:2

2-12

Car. 2

RX
RX div

TX 1

Module 0

012

Logical numbering of Carrier (Cell 0)

Module 1

RX 0

RX
RX div

Car. 3

206

Car. 4

204

TX 0

SLOT 0

RX 3

203

RX

Module 1

RX 2

CU 0

RX 1 202

011

RX div

CU 1

205

CU 2

201

CU 3

SLOT 0

Module 0

RX 0

Car. 1

DUAMCO 0
4:2

DUAMCO 0
4:2

2.1.1.2.1 Configuration
No.
of
cells

No. of
Carrier

1
1
1
1
1

1
2
3
4
5

1
2
3
4
5

0
0
0
0
0

0
0
0
0
0

No. of Carriers in
each cell
0
1
2

Variants RX

Variants TX

201,205
201,205,202,206
201,205,202,206,203,207
201,205,202,206,203,207,204,208
201,205,202,206,203,207,204,208,209,
213
201,205,202,206,203,207,204,208,209,
213,210,214
201,205,202,206,203,207,204,208,209,
213,210,214,211,215
201,205,202,206,203,207,204,208,209,
213,210,214,211,215,212,216

011
011,012
011,012,013
011,012,013,014
011,012,013,014,
015
011,012,013,014,
015,016
011,012,013,014,
015,016,017
011,012,013,014,
015,016,017,018

A30808-X3247-G900-01-7618

2-13

Module 0

301
309

RX
RX div

RX
RX div

RX
RX div

RX
RX div

031

032

036

035

034

033

037

038

DUAMCO 0
8:2
TX 0

TX 1

TX 2

TX 3

TX 0

TX 1

TX 2

TX 3

Logical numbering of Carrier (Cell 0)

Car. 1
Car. 2

302

310

311

312

RX
RX div

RX
RX div

RX
RX div

RX
RX div

SLOT 0

RX 0

303
304
305
306
307
308

313

314

315

316

A30808-X3247-G900-01-7618

SLOT 1

DUAMCO 0
8:2

Module 1

RX 1
RX 2
RX 3
RX 4
RX 5
RX 6
RX 7
RX 0
RX 1
RX 2
RX 3
RX 4
RX 5
RX 6
RX 7

CU 3

2.1.1.3 DUAMCO 8:2 , 1Cell (X,0,0)

2-14

CU 6

Car. 3
Car. 4
Car. 5
Car. 6
Car. 7
Car. 8

Module 0

(SLOT 2)

Module 1

(SLOT 3)

SLOT 0

CU 0
CU 1
CU 7

CU 2
CU 4
CU 5

SLOT 1
(SLOT 2)
(SLOT 3)

2.1.1.3.1 Configuration
No.
of
cells

No. of
Carrier

No. of Carriers in
each cell
0
1
2

1
1
1
1
1

1
2
3
4
5

1
2
3
4
5

0
0
0
0
0

0
0
0
0
0

Variants RX

Variants TX

301,309
301,309,302,310
301,309,302,310,303,311
301,309,302,310,303,311,304,312
301,309,302,310,303,311,304,312,305,
313
301,309,302,310,303,311,304,312,305,
313,306,314
301,309,302,310,303,311,304,312,305,
313,306,314,307,315
301,309,302,310,303,311,304,312,305,
313,306,314,307,315,308,316

031
031,032
031,032,033
031,032,033,034
031,032,033,034,
035
031,032,033,034,
035,036
031,032,033,034,
035,036,037
031,032,033,034,
035,036,037,038

A30808-X3247-G900-01-7618

2-15

2.1.1.4 DUAMCO 2:2 , 2Cell (X,X,0)

TX 0

SLOT 0
002

003

004

TX 0

RX
RX div

005

006

TX 0

SLOT 2

Module 0

RX
RX div

CU 6

RX
RX div

TX 0

008

TX 0

SLOT 3

115
116
RX 1
RX

TX 0

A30808-X3247-G900-01-7618

Module 1

Module 1

RX 0

RX div

2-16

007

Module 0

RX
RX div

CU 4

114

CU 5

Module 0

SLOT 3

RX 1

113

Carrier 2

DUAMCO 3
2:2

DUAMCO 3
2:2
RX 0

Carrier 3

112

Logical numbering of Carrier (Cell 1)

111

Carrier 1

RX 1

110

CU 7

Module 0

SLOT 2
Module 1

RX 0

109

Carrier 4

DUAMCO 2
2:2

DUAMCO 2
2:2

RX 1

TX 0

Carrier 4

108

Module 1

107

RX 1

RX 0

Carrier 3

RX
RX div

SLOT 1

106

Module 0

105

CU 2

Module 0

RX 0

Module 1

SLOT 1

RX 1

DUAMCO 1
2:2

CU 3

DUAMCO 1
2:2

TX 0

Carrier 2

RX

Module 1

104

Logical numbering of Carrier (Cell 0)

001

103

RX div

RX 0

Carrier 1

RX
RX div

Module 0

102

Module 1

RX 1

101

CU 1

Module 0

RX 1

RX 0

Module 1

SLOT 0

RX 0

DUAMCO 0
2:2
CU 0

DUAMCO 0
2:2

2.1.1.4.1 Configuration
No.
of
cells

No. of
Carrier

No. of Carriers in
each cell
0
1
2

2
2
2
2
2
2
2

2
3
3
4
4
4
5

1
2
1
2
3
1
4

1
1
2
2
1
3
1

0
0
0
0
0
0
0

Variants RX

Variants TX

101,103,114,116
101,103,102,104,114,116
101,103,114,116,113,115
101,103,102,104,114,116,113,115
101,103,102,104,105,107,114,116,
101,103,114,116,113,115,110,112
101,103,102,104,105,107,106,108,114,
116
101,103,114,116,113,115,110,112,109,
111
101,103,102,104,105,107,114,116,113,
115
101,103,102,104,114,116,114,115,116,
110,112
101,103,102,104,105,107,106,108,114,
116,113,115
101,103,102,104,114,116,113,115,110,
112,109,111
101,103,102,104,105,107,114,116,113,
115,110,112
101,103,102,104,105,107,106,108,114,
116,113,115,110,112
101,103,102,104,105,107,114,116,113,
115,110,112,109,111
101,103,102,104,105,107,106,108,114,
116,113,115,110,112,109,111

001 008
001,002,008
001,008,007
001,002,008,007
001,002,003,008
001,008,007,006
001,002,003,004,
008
001,008,007,006,
005
001,002,003,008,
007
001,002,008,007,
006
001,002,003,004,
008,007
001,002,008,007,
006,005
001,002,003,008,
007,006
001,002,003,004,
008,007,006
001,002,003,008,
007,006,005
001,002,003,004,
008,007,006,005

A30808-X3247-G900-01-7618

2-17

RX 3

RX 2

RX 1

RX 0

RX 3

RX 2

RX 1

RX 0

DUAMCO 0
4:2

SLOT 0
DUAMCO 3
4:2

RX 1

RX 0

RX 2
RX 3
RX 0
RX 1
RX 2
RX 3

201
202
203
204
205
206
207
208

209
210
211
212
213
214
215
216

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

011

013

012

014

015

016

017

018

TX 1

TX 0

TX 1

TX 0

DUAMCO 3
4:2

TX 1

TX 0

TX 1

TX 0

DUAMCO 0
4:2

A30808-X3247-G900-01-7618

2.1.1.5 DUAMCO 4:2 , 2Cell (X,X,0)

2-18

Logical numbering of Carrier (Cell 0)


Logical numbering of Carrier (Cell 1)

Car. 1
Car. 2
Car. 3
Car. 4
Car. 4
Car. 3
Car. 2
Car. 1

SLOT 0
(SLOT 1)
(SLOT 2)
SLOT 3

Module 0
Module 1
Module 0
Module 1

CU 0
CU 2

CU 1
CU 3
CU 6
CU 7
CU 4
CU 5

Module 0
Module 1
Module 0
Module 1

(SLOT 1)
(SLOT 2)
SLOT 3

2.1.1.5.1 Configuration
No.
of
cells

No. of
Carrier

No. of Carriers in
each cell
0
1
2

2
2
2
2
2
2
2

2
3
3
4
4
4
5

1
2
1
2
3
1
4

1
1
2
2
1
3
1

0
0
0
0
0
0
0

Variants RX

Variants TX

201,205,212,216
201,205,202,206,212,216
201,205,212,216,211,215
201,205,202,206,212,216,211,215
201,205,202,206,203,207,212,216
201,205,212,216,211,215,210,214
201,205,202,206,203,207,204,208,212,
216
201,205,212,216,211,215,210,214,209,
213
201,205,202,206,203,207,212,216,211,
215
201,205,202,206,212,216,211,215,210,
214
201,205,202,206,203,207,204,208,212,
216,211,215
201,205,202,206,212,216,211,215,210,
214,209,213
201,205,202,206,203,207,212,216,211,
215,210,214
201,205,202,206,203,207,204,208,212,
216,211,215,210,214
201,205,202,206,203,207,212,216,211,
215,210,214,209,213
201,205,202,206,203,207,204,208,212,
216,211,215,210,214,209,213

011,018
011,012,018
011,018,017
011,012,018,017
011,012,013,018
011,018,017,016
011,012,013,014,
018
011,018,017,016,
015
011,012,013,018,
017
011,012,018,017,
016
011,012,013,014,
018,017
011,012,018,017,
016
011,012,013,018,
017,016
011,012,013,014,
018,017,016
011,012,013,018,
017,016,015
011,012,013,014,
018,017,016,015

A30808-X3247-G900-01-7618

2-19

2.1.1.6 DUAMCO 2:2 / 4:2 , 2Cell (X,X,0)

TX 0

SLOT 0
002
TX 0

003

004

TX 0

SLOT 1

107

RX

TX 0

RX 2
RX 3

2-20

213
214

RX
RX div

215
216

RX
RX div

TX 0

TX 1

A30808-X3247-G900-01-7618

Car. 3

018

TX 1

Car. 2

017

Module 0

016

SLOT 3

RX div

TX 0

Car. 1

RX 1

RX
212

015

Module 1

Module 1

RX 0

211

CU 6

RX 3

RX
RX div

CU 7

RX 2

210

CU 4

RX 1

209

CU 5

SLOT 3

Module 0

RX 0

Car. 4

DUAMCO 3
4:2

DUAMCO 3
4:2

Logical numbering of Carrier (Cell 1)

(SLOT 2)

(SLOT 2)

RX div

Module 1

108
RX 1

Carrier 4

Module 0

RX div

RX 0

Module 1

SLOT 1

RX
106

Carrier 3

105
RX 0

CU 2

DUAMCO 1
2:2

CU 3

DUAMCO 1
2:2

Carrier 2

RX

Module 1

104

Logical numbering of Carrier (Cell 0)

001

103

RX div

RX 1

Carrier 1

RX
RX div

Module 0

102

Module 0

RX 1

101

CU 1

Module 0

RX 1

RX 0

Module 1

SLOT 0

RX 0

DUAMCO 0
2:2
CU 0

DUAMCO 0
2:2

2.1.1.6.1 Configuration
No.
of
cells

No. of
Carrier

2
2
2
2
2
2
2

2
3
3
4
4
4
5

1
2
1
2
3
1
4

1
1
2
2
1
3
1

0
0
0
0
0
0
0

No. of Carriers in
each cell
0
1
2

Variants RX

Variants TX

101,103,212,216
101,103,102,104,212,216
101,103,212,216,211,215
101,103,102,104,212,216,211,215
101,103,102,104,105,107,212,216
101,103,212,216,211,215,210,214
101,103,102,104105,107,106,108,212,
216
101,103,212,216,211,215,210,214,209,
213
101,103,102,104,101,107,212,216,211,
215
101,103,102,104,212,216,211,215,210,
214
101,103,102,104,105,107,106,108,212,
216,211,215
101,103,102,104,212,216,211,215,210,
214,209,213
101,103,102,104,105,107,212,216,211,
215,210,214
101,103,102,104,105,107,106,108,212,
216,211,215,210,214
101,103,102,104,105,107,212,216,211,
215,210,214,209,213
101,103,104,102,105,107,106,108,212,
216,211,215,210,214,209,213

001,018
001,002,018
001,018,017
001,002,018,017
001,002,003,018
001,018,017,016
001,002,003,004,
018
001,018,017,016,
015
001,002,003,018,
017
001,002,018,017,
016
001,002,003,004,
018,017
001,002,018,017,
016,015
001,002,003,018,
017,016
001,002,003,004,
018,017,016
001,002,003,018,
017,016,015
001,002,003,004,
018,017,016,015

A30808-X3247-G900-01-7618

2-21

Module 1

SLOT 3

2-22

RX 1

RX 0

114
RX

RX div
RX

113

RX div

RX

RX div

RX

107

RX 1
108
003

004
TX 0

TX 0

DUAMCO 3
2:2

RX 0

115

RX 1

116

007

008

A30808-X3247-G900-01-7618

TX 0

DUAMCO 1
2:2

DUAMCO 3
2:2

TX 0

Carrier 1

Logical numbering of Carrier (Cell 0)

Carrier 2

Module 0

TX 0

Logical numbering of Carrier (Cell 2)

Carrier 1

SLOT 0

104

Carrier 2

DUAMCO 1
2:2
TX 0

Module 1

CU 0

DUAMCO 0
2:2

Logical numbering of Carrier (Cell 1)

RX div

002

Module 0

RX 1

Module 1

Module 0

SLOT 0

103

Carrier 2

RX 0

SLOT 1

105

CU 1

RX

CU 2

RX div

001

Carrier 1

(SLOT 2)

RX 1
106

RX

Module 0

RX 0

RX div

CU 3

Module 1

DUAMCO 0
2:2

Module 1

Module 0

SLOT 1

RX 0

102

CU 4

Module 1

RX 1

101

CU 5

(SLOT 2)

RX 0

SLOT 3

Module 0

2.1.1.7 DUAMCO 2:2 , 3Cell (X,X,X)

2.1.1.7.1 Configuration
No.
of
cells

No. of
Carrier

3
3
3
3
3

3
4
4
4
5

1
2
1
1
2

1
1
2
1
2

1
1
1
2
1

No. of Carriers in
each cell
0
1
2

Variants RX

Variants TX

101,103,114,116,105,107
101,103,102,104,114,116,105,107
101,103,114,116,113,115,105,107
101,103,114,116,105,107,106,108
101,103,102,104,114,116,113,115,105,
107
101,103,102,104,114,116,105,107,106,
108
101,103,114,116,113,115,105,107,106,
108,
101,103,102,104,114,116,113,115,105,
107,106,108

001,008,003
001,002,008,003
001,008,003,004,
001,008,003,004
001,002,008,007,
003
001,002,008,003,
004
001,008,007,003,
004
001,002,008,007,
004,005

A30808-X3247-G900-01-7618

2-23

RX 1

RX 0

RX 1

RX 0

DUAMCO 1
2:2

RX 1

RX 0

RX 1

RX 0

DUAMCO 0
2:2
Module 0

DUAMCO 3
4:2

RX 1

RX 0

RX 2
RX 3
RX 0
RX 1
RX 2
RX 3

101
102

103
104

105
106

107
108

209
210
211
212
213
214
215
216

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX

016

RX div

RX
RX div

RX
RX div

001

002

003

004

016

015

017

018

DUAMCO 0
2:2
TX 0

TX 0

DUAMCO 1
2:2
TX 0

TX 0

DUAMCO 3
4:2
TX 0

TX 1

TX 0

TX 1

A30808-X3247-G900-01-7618

Logical numbering of Carrier (Cell 0)


Logical numbering of Carrier (Cell 1)
Logical numbering of Carrier (Cell 2)

Module 0
Module 1
Module 0

CU 1
CU 2

Carrier 1
Carrier 2
Carrier 1
Carrier 2
Car. 4
Car. 3
Car. 2
Car. 1

SLOT 0
SLOT 1
(SLOT 2)
SLOT 3

Module 1
Module 0
Module 1

CU 0

2.1.1.8 2x DUAMCO 2:2 , DUAMCO 4:2 , 3Cell (X,X,X)

2-24

SLOT 3

CU 3
CU 7

CU 6
CU 4
CU 5

SLOT 0
SLOT 1
(SLOT 2)

Module 1
Module 0
Module 1
Module 0
Module 1

2.1.1.8.1 Configuration
No.
of
cells

No. of
Carrier

No. of Carriers in
each cell
0
1
2

3
3
3
3
3

3
4
4
4
5

1
2
1
1
2

1
1
2
1
2

1
1
1
2
1

Variants RX

Variants TX

101,103,114,116,105,107
101,103,102,104,114,116,105,107
101,103,114,116,113,115,105,107
101,103,114,116,105,107,106,108
101,103,102,104,114,116,113,115,105,
107
101,103,102,104,114,116,105,107,106,
108
101,103,114,116,113,115,105,107,106,
108,
101,103,105,107,212,216,211,215,210,
214
101,103,102,104,105,107,106,108,212,
216,211,215
101,103,102,104,105,107,212,216,211,
215,210,214
101,103,105,107,106,108,212,216,211,
215,210,214
101,103,105,107,212,216,211,215,210,
214,209,213
101,103,102,104,105,107,108,212,216,
211,215,210,214
101,103,102,104,105,107,212,216,211,
215,210,214,209,213
101,103,105,107,106,108,212,216,211,
215,210,214,209,213
101,103,102,104,105,107,106,108,212,
216,211,215,210,214,209,213

001,008,003
001,002,008,003
001,008,003,004,
001,008,003,004
001,002,008,007,
003
001,002,008,003,
004
001,008,007,003,
004
001,003,018,017,
016
001,002,008,007,
004,005
001,002,003,018,
017,016
001,003,004,018,
017,016
001,003,018,017,
016,015
001,002,003,004,
018,017,016
001,002,003,018,
017,016,015
001,003,004,018,
017,016,015
001,002,003,004,
018,017,016,015

A30808-X3247-G900-01-7618

2-25

2.1.2 Description of Variants

2.1.2.1 TX-Path

2:2 TX
DUAMCO 0 (slot 0)
Variants
CU 0
CU 1
CU 2
CU 3
CU 4
CU 5
CU 6
CU 7

DUAMCO 0
_TX0

DUAMCO 1
_TX1

DUAMCO 1 (slot1)
DUAMCO 0
_TX0

DUAMCO 1
_TX1

DUAMCO 2 (slot2)
DUAMCO 0
_TX0

DUAMCO 1
_TX1

DUAMCO 3 (slot3)
DUAMCO 0
_TX0

DUAMCO 1
_TX1

001
002
003
004
007
008
005
006

4:2 TX
DUAMCO 0 (slot 0)
Variants
CU 0
CU 1
CU 2
CU 3
CU 4
CU 5
CU 6
CU 7

DUAMCO 0
_TX0

DUAMCO 0
_TX1

DUAMCO 1 (slot1)
DUAMCO 1
_TX0

DUAMCO 1
_TX1

011

CU 0
CU 1
CU 2
CU 3
CU 4
CU 5
CU 6
CU 7

2-26

DUAMCO 0
_TX1

DUAMCO 1
_TX0

012

021
013

020
014

DUAMCO 0
_TX0

DUAMCO 1
_TX1

022

DUAMCO 2 (slot2)
Variants

DUAMCO 0
_TX0

DUAMCO 0
_TX1

019

DUAMCO 3 (slot3)
DUAMCO 1
_TX0

DUAMCO
1_TX1

DUAMCO 0
_TX0

DUAMCO 0
_TX1

017

DUAMCO 1
_TX1

025
018

015

DUAMCO 1
_TX0

026
023

016

024

A30808-X3247-G900-01-7618

8:2 TX
DUAMCO
0
Variants
CU 0
CU 1
CU 2
CU 3
CU 4
CU 5
CU 6
CU 7

DUAMCO 0
_TX0

DUAMCO 0
_TX1

DUAMCO 0
_TX2

DUAMCO 0
_TX3

DUAMCO 1
_TX0

DUAMCO 1
_TX1

DUAMCO 1
_TX2

DUAMCO 1
_TX3

031
032
033
034
037
038
035
036

2.1.2.2 RX-Path

2:2 RX
DUAMCO 0 (slot 0)
DUA(2)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(2)0
_RX1

DUA(2)0
_RX2

DUA(2)0
_RX3

DUA(2)1
_RX0

DUA(2)1
_RX1

DUA(2)1
_RX2

DUA(2)1
_RX3

101
103
102
104

A30808-X3247-G900-01-7618

2-27

DUAMCO 1 (slot 1)
DUA(2)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(2)0
_RX1

DUA(2)0
_RX2

DUA(2)0
_RX3

DUA(2)1
_RX0

DUA(2)1
_RX1

DUA(2)1
_RX2

DUA(2)1
_RX3

DUA(2)1
_RX2

DUA(2)1
_RX3

105
107
106
108

DUAMCO 2 (slot 2)
DUA(2)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

2-28

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(2)0
_RX1

DUA(2)0
_RX2

DUA(2)0
_RX3

DUA(2)1
_RX0

DUA(2)1
_RX1

109
111
110
112

A30808-X3247-G900-01-7618

DUAMCO 3 (slot 3)
DUA(2)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(2)0
_RX1

DUA(2)0
_RX2

DUA(2)0
_RX3

DUA(2)1
_RX0

DUA(2)1
_RX1

DUA(2)1
_RX2

DUA(2)1
_RX3

113
115
114
116

4:2 RX
DUAMCO 0 (slot0)
DUA(4)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(4)0
_RX1

DUA(4)0
_RX2

DUA(4)0
_RX3

DUA(4)1
_RX0

DUA(4)1
_RX1

DUA(4)1
_RX2

DUA(4)1
_RX3

201
205
202
206
203
207
204
208

A30808-X3247-G900-01-7618

2-29

DUAMCO 1 (slot1)
DUA(4)0
_RX0

Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(4)0
_RX1

DUA(4)0
_RX2

DUA(4)0
_RX3

DUA(4)1
_RX0

DUA(4)1
_RX1

DUA(4)1
_RX2

DUA(4)1
_RX3

217
221
218
222
219
223
220
224

DUAMCO 2 (slot2)
DUA(4)0
_RX0

Variantsn
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

2-30

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(4)0
_RX1

DUA(4)0
_RX2

DUA(4)0
_RX3

DUA(4)1
_RX0

DUA(4)1
_RX1

DUA(4)1
_RX2

DUA(4)1
_RX3

227
231
228
232
225
229
226
230

A30808-X3247-G900-01-7618

DUAMCO 3 (slot3)
Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

DUA(4)0
_RX0
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(4)0
_RX1

DUA(4)0
_RX2

DUA(4)0
_RX3

DUA(4)1
_RX0

DUA(4)1
_RX1

DUA(4)1
_RX2

DUA(4)1
_RX3

211
215
212
216
209
213
210
214

8:2 RX
DUAMCO
(slot0+1)
Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

0 Module 0

DUA(8)0
_RX0
301

DUA(8)0
_RX1

DUA(8)0
_RX2

DUA(8)0
_RX3

DUA(8)0
_RX4

DUA(8)0
_RX5

DUA(8)0
_RX6

DUA(8)0
_RX7

302
303
304
307
308
305
306

A30808-X3247-G900-01-7618

2-31

DUAMCO0
(slot0+1)
Variants
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7

2-32

Module 1

DUA(8)1
_RX0
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DUA(8)1
_RX1

DUA(8)1
_RX2

DUA(8)1
_RX3

DUA(8)1
_RX4

DUA(8)1
_RX5

DUA(8)1
_RX6

DUA(8)1
_RX7

309
310
311
312
315
316
313
314

A30808-X3247-G900-01-7618

2.2

BS240/241 with FICOM and DIAMCO

2.2.1 Survey of Variants


Here some variants of system cabling with FICOM and DIAMCO are given.

A30808-X3247-G900-01-7618

2-33

506

RX

Carrier 1

403

RX div

TX 1

TX 0

Expansion

DIAMCO 0
RX 0
RX 1

RX 4

507

RX 5

508

RX 6

RX
RX div

404

Carrier 4

RX 3

CU 3

Module 0

RX 2

TX 1

RX 7

510

RX
RX div

405

406

Carrier 5

509

RX 2

CU 6

RX 1

CU 7

Module 1

RX 0
TX 0

RX 3

514

515
516

2-34

RX
RX div

RX
RX div

407

408

A30808-X3247-G900-01-7618

Carrier 6
Carrier 7

513

TX 1

TX 0

TX 1

Carrier 8

RX div

SLOT 2

RX

512

CU 5

511

CU 4

RX 7

SLOT 3

RX 6

Expansion

RX 5

Expansion

RX 4

Logical numbering of Carrier (Cell 0)

505

RX div

Carrier 2

RX
504

Carrier 3

503

SLOT 0

402

TX 0

Base

401

SLOT 1

RX
RX div

CU 0

502

CU 1

501

CU 2

2.2.1.1 FICOM , 1Cell (X,0,0)

2.2.1.1.1 Configuration
No.
of
cells

No. of
Carrier

1
1
1
1
1

1
2
3
4
5

1
2
3
4
5

0
0
0
0
0

0
0
0
0
0

No. of Carriers in
each cell
1
2
3

Variants RX

Variants TX

501,502
501,502,503,504,
501,502,503,504,505,506
501,502,503,504,505,506,507,508
501,502,503,504,505,506,507,508,509,
510
501,502,503,504,505,506,507,508,509,
510,511,512
501,502,503,504,505,506,507,508,509,
510,511,512,513,514
501,502,503,504,505,506,507,508,509,
510,511,512,513,514,515,516

401
401,402
401,402,403
401,402,403,404
401,402,403,404,
405
401,402,403,404,
405,406
401,402,403,404,
405,406,407
401,402,403,404,
405,406,407,408

A30808-X3247-G900-01-7618

2-35

2.2.1.2 FICOM , 2Cell (max. 4,4,0)

DIAMCO 0
RX 0
RX 1
RX 2
RX 3
RX 4
RX 5
RX 6
RX 7
RX 0
RX 1
RX 2
RX 3
RX 4
RX 5
RX 6
RX 7

501
502

503
504

505
506

507
508

525
526

529

527
528

RX 1

530

RX 3
RX 4
RX 5
RX 6
RX 7

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

401

402

403

404

405

406

407

408

A30808-X3247-G900-01-7618

532

531

RX 2

RX 0

RX 7

RX 6

RX 5

RX 4

RX 3

RX 2

RX 1

RX 0

DIAMCO 1

2-36

TX 0

TX 1

TX 0

TX 1

TX 0

TX 1

TX 0

TX 1

Logical numbering of Carrier (Cell 0)


Logical numbering of Carrier (Cell 1)

Carrier 1
Carrier 2
Carrier 3
Carrier 4
Carrier 4
Carrier 3
Carrier 2
Carrier 1

SLOT 1

SLOT 0
SLOT 2
SLOT 3

Expansion

Base
Expansion
Base

CU 0
CU 1
CU 2
CU 3
CU 6
CU 7
CU 4
CU 5

Module 0
Module 1
Module 0
Module 1

2.2.1.2.1 Configuration
No.
of
cells

No. of
Carrier

2
2
2
2
2
2

2
3
3
4
4
5

1
2
1
3
1
3

1
1
2
1
3
2

0
0
0
0
0
0

No. of Carriers in
each cell
1
2
3

Variants RX

Variants TX

501,502,531,532
501,502,503,504,531,532
501,502,531,532,529,530
501,502,503,504,505,506,531,532
501,502,531,532,529,530,527,528
501,502,503,504,505,506,531,532,529,
530
501,502,503,504,531,532,529,530,527,
528
501,502,503,504,505,506,507,508,531,
532
501,502,531,532,529,530,527,528,525,
526
501,502,503,504,505,506,507,508,531,
532,529,530
501,502,503,504,531,532,509,530,527,
528,525,526
501,502,503,504,505,506,507,508,531,
532,529,530,527,528,525,526
501,502,503,504,505,506,531,532,529,
530,527,528,525,526
501,502,503,504,505,506,507,508,531,
532,529,530,527,528,525,526

401,408
401,402,408
401,408,407
401,402,403,408
401,408,407,406
401,402,403,408,
407
401,402,408,407,
406
401,402,403,404,
408
401,408,407,406,
405
401,402,403,404,
408,407
401,402,408,407,
406,405
401,402,403,404,
408,407,406
401,402,403,408,
407,406,405
401,402,403,404,
408,407,406,405

A30808-X3247-G900-01-7618

2-37

501
502

503

522

521

504

RX 1
RX 3
RX 4
RX 5
RX 6
RX 7

DIAMCO 1
RX 0
RX 1
RX 2
RX 3
RX 4
RX 5
RX 6
RX 7

524

525
526

529

527
528

RX 1

530

RX 3
RX 4
RX 5
RX 6
RX 7

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

RX
RX div

401

402

403

404

405

406

407

408

A30808-X3247-G900-01-7618

531
532

RX 2

RX 0

523

RX 2

RX 0

RX 7

RX 6

RX 5

RX 4

RX 3

RX 2

RX 1

RX 0

DIAMCO 0

2.2.1.3 FICOM , 2Cell (max. 2,6,0)

2-38

TX 0

TX 1

TX 0

TX 1

TX 0

TX 1

TX 0

TX 1

Logical numbering of Carrier (Cell 0)


Logical numbering of Carrier (Cell 1)

Carrier 1
Carrier 2
Carrier 6
Carrier 5
Carrier 4
Carrier 3
Carrier 2
Carrier 1

SLOT 1

SLOT 0
SLOT 2
SLOT 3

Expansion

Base
Expansion
Base

CU 0
CU 1
CU 2
CU 3
CU 6
CU 7
CU 4
CU 5

Module 0
Module 1
Module 0
Module 1

2.2.1.3.1 Configuration
No.
of
cells

No. of
Carrier

2
2
2
2
2
2

2
3
3
4
4
5

1
2
1
2
1
2

1
1
2
2
3
3

0
0
0
0
0
0

Variants RX

Variants TX

501,502,531,532
501,502,503,504,531,532
501,502,531,532,529,528
501,502,503,504,531,532,529,530
501,502,531,532,529,530,527,528
501,502,503,504,531,532,529,530,527,
528
501,502,531,532,529,530,527,528,525,
526
501,502,503,504,531,532,529,530,527,
528,525,526
501,502,531,532,529,530,527,528,525,
526,523,524
501,502,503,504,531,532,529,530,527,
528,525,526,523,524
501,502,531,532,529,530,527,528,525,
526,523,524,521,522
501,502,503,504,531,532,529,530,527,
528,525,526,523,524,521,522

401,408
401,402,408
401,408,407
401,402,408,407
401,408,407,406
401,402,408,407,
406
401,408,407,406,
405
401,402,408,407,
406,405
401,408,407,406,
405,404
401,402,408,407,
406,405,404
401,408,407,406,
405,404,403
401,402,408,407,
406,405,404,403

No. of Carriers in
each cell
1
2
3

2.2.2 Description of Variants

2.2.2.1 TX-Path

TX
Varianten
CU 0
CU 1
CU 2
CU 3
CU 4
CU 5
CU 6
CU 7

Base
TX0

TX1

E0
TX0

TX1

E1
TX0

TX1

E2
TX0

TX1

401
402
403
404
407
408
405
406

A30808-X3247-G900-01-7618

2-39

2.2.2.2 RX-Path

RX
DIAMCO 0
Varianten
CU0 Rx
CU1
CU2
CU3
CU4
CU5
CU6
CU7

Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV
Rx
Rx DIV

DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1
_RX0 _RX1 _RX2 _RX3 _RX4 _RX5 _RX6 _RX7 _RX0 _RX1 _RX2 _RX3 _RX4 _RX5 _RX6 _RX7
501
502
503
504
505
506
507

508
513
514
515
516
509
510
511
512

DIAMCO 1
Varianten

DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA0 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1 DIA1
_RX0 _RX1 _RX2 _RX3 _RX4 _RX5 _RX6 _RX7 _RX0 _RX1 _RX2 _RX3 _RX4 _RX5 _RX6 _RX7

CU0 Rx
Rx DIV
CU1 Rx
Rx DIV
CU2 Rx
Rx DIV
CU3 Rx
Rx DIV
CU4 Rx
Rx DIV
CU5 Rx
Rx DIV
CU6 Rx
Rx DIV
CU7 Rx

521
522
523
524
529
530
531
532
525
526
527

Rx DIV

2-40

528

A30808-X3247-G900-01-7618

15

14

13

11

10

DC-Panel
33 1)

Abdeckhaube / Cover

Service 2

1) Component of MK: CARSV1 (S30864-X211-A29)

12

c c c

DCP:RSHS1

9 8 7 6

b b b

a a a

DCP:RSHS2
-48 V

DC-Panel

Service 1

34 1)

DC-Distribution

A30808-X3247-G900-01-7618
c c c c c

b b b b b

14 13 12 11 10

a a a a a

c c

b b

a a

+0 V

c c

b b

6 5

a a

1) 35

c c

3 2

a a

-48 V

DCP:RSHB

DC-Panel

Base

DC-Panel

Extension 1

1) 36

c c c c c

b b b b b

14 13 12 11 10

a a a a a

+0 V

c c

b b

a a

c c

b b

6 5

a a

-48 V

DCP:RSHE

DC-Panel

b b

c c c

3 2 1

a a a

Extension 2

3.1

+0 V

3
INTERRACK / INTERSHELTER CABLING

Interrack Cabling

3.1.1 DC Cabling

3-41

CABLING
Number

From

1)
To

Color

DC - Panel S1
33

34

35

36

0V

13b

Rack S2 / 5b

Black

-48V

14b

Rack S2 / 2b

Blue

0V

11b

Rack B / 9b

Black

-48V

12b

Rack B / 4b

Blue

0V

9b

Rack E1 / 9b

Black

-48V

10b

Rack E1 / 4b

Blue

0V

7b

Rack E2 / 9b

Black

-48V

8b

Rack E2 / 4b

Blue

1) Component of MK: CARSV1 (S30864-X211-A29)

3-42

A30808-X3247-G900-01-7618

Service 2/3

Service 2/2

Service 2/1

F:AC/DC 1

Service 1

Abdeckhaube / Cover

b
1
2

112/3

110/2

c
111/2

0V

110/3

BAT 1

MK:BAT

MK:BAT

3)

MK:BAT

1)
BAT 2
MK:BAT

1)
BAT 3

BAT 1

1)

BAT 1

F:AC/DC 2
110/1
111/1

T1

1)
BAT 1

BAT 0

T0

14 15 16 17

MK:BAT

1)
BAT 2

112/1

1)

110/4
111/4

T0

F:AC/DC 2

3)
111/3

T1

T0

T1

3)
MK:BAT

-48V

F:AC/DC 1

A30808-X3247-G900-01-7618

112/2
112/4

25 26 27 28

MK:BATTERY

3.1.2 Battery Cabling

INTERNAL BATTERY INTERFACE


Battery trace

1)
BAT 0

T0

3)

b
T1

1) Batterie-Entlftung siehe F: Battery


Battery bleeding see F: Battery

3) Von Entlftungsschlauch V39113-Z-X700 1m abschneiden und


pro Service-Rack fr die Batterie-Entlftung mitliefern.
Cut off 1m air-vent tube V39113-Z-X700 and for battery air-vent
deliver one with each service rack.

BAT 2

BAT 3

3-43

Battery-Cable
Number

From

2)

To

Factory-No.

Length
(mm)

Color

110/1
111/1

S1/F:AC/DC1-26b
S1/F:AC/DC1-25b

S1/BAT 0/ - (-48V)
S1/BAT 0/ + (+0V)

S30864-X211-A46
S30864-X211-A46

1500

Blue
Black

110/2
111/2

S1/F:AC/DC1-28b
S1/F:AC/DC1-27b

S2/1 MK:BAT1 -2a


S2/1 MK:BAT1 -1a

S30864-X211-A47
S30864-X211-A47

2500

Blue
Black

110/3
111/3

S1/F:AC/DC2-15b
S1/F:AC/DC2-14b

S2/2 MK:BAT2 -2a


S2/2 MK:BAT2 -1a

S30864-X211-A48
S30864-X211-A48

3700

Blue
Black

110/4
111/4

S1/F:AC/DC2-17b
S1/F:AC/DC2-16b

S2/3 MK:BAT3 -2a


S2/3 MK:BAT3 -1a

S30864-X211-A49
S30864-X211-A49

4200

Blue
Black

2) Kabellngen bei Bedarf anpassen bzw. krzen.


If required, adapt and/or shorten the cable lengths.

Tempresistor-Cable
Number

3-44

From

To

Factory-No.

Length
(m)

112/1

Service 1

/ Bat 0(+)

S1/ F:AC/DC 1 T0

S30864-X211-A44

2,5

112/2

Service 2/1 / Bat 1(+)

S1/ F:AC/DC 1 T1

S30864-X211-A44

2,5

112/3

Service 2/2 / Bat 2(+)

S1/ F:AC/DC 2 T0

S30864-X211-A45

5,5

112/4

Service 2/3 / Bat 3(+)

S1/ F:AC/DC 2 T1

S30864-X211-A45

5,5

A30808-X3247-G900-01-7618

3.1.3 CAN-Bus Cabling

CAN-BUS- Cabling

Ansicht von oben / Top view

A30808-X3247-G900-01-7618

EMI-P: RS

EMI-P: RB

EMI-P: RE

CAN OUT CAN IN

CAN OUT -48V

CAN OUT CAN IN


Serial
IF

CAN TEST LPA

CAN TEST LPA

CAN TEST LPA


Rear side
245

1)

246

247
248
249

Front side

Service 2/2

Service 2/1

Service 1

Achtung: Zuordnung der Kabellgen entsprechend der Ausbaustufe ! Hier: 5 Ausbaustufen: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2
Note: Assignment of the cable lenghts in accordance to the Extension Phase! Here: 5 Phases: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2

Base

Extension 1

Extension 2

1) Der CAN Bus ist am Ende mit dem Abschluwiderstand S30861-K2047-X abzuschlieen.
(Bestandteil des Base-Shelters)
Lock the bus link at the end with the terminating resistor S30861-K2047-K .
(Component from Base-Shelter)

3-45

Verkabelungsbeispiel
Number

From

CABLING EXAMPLE
To

CAN BUS OUT

2)
Code No

Length

CAN BUS IN

245

Base

Service1

S30864-X210-A11

1,2m

246

Service1

Extension 1

S30864-X210-A12

1,9m

247

Extension 1

Service 2/1

S30864-X210-A13

2,6m

248

Service 2/1

Extension 2

S30864-X210-A14

3,3m

249

Extension 2

Service 2/2

S30864-X210-A15

4,0m

2) Achtung: Zuordnung der Kabellgen entsprechend der Ausbaustufe ! Hier: 5 Ausbaustufen: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2
Note: Assignment of the cable lenghts in accordance to the Extension Phase! Here: 5 Phases: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2

3-46

WS
BL
TK
VI

WS
OR
TK
VI

2
9
5
3
10
-

Signalname

Anschlusspunkt
Connection point

Aderfarbe
Wire color

Vierer

CAN-BUS Steckerbelegung (15-pol.)


CAN-BUS CONNECTOR ASSIGNMENT (15-pol.)

CAN_L
GND
nc
nc
CAN_RESET_L
CAN_GND
CAN_H
nc

Symm. HF-Leitung
09YS(ST)CY 4x2x0,6/1,2-120 GR
V42255-Z1001-A4

A30808-X3247-G900-01-7618

3.1.4 SELIC-Cabling

SELIC- Cabling (CC-LINK -BUS)


Ansicht von oben / Top view

A30808-X3247-G900-01-7618

EMI-P: RB

EMI-P: RE

Ext.1 CU 4...7

CU 4...7

Ext.1 CU 0...3

CU 0...3

Ext.2 CU 4...7
Ext.2 CU 0...3
Rear side
1)

1)

Front side

Base
1) Component of MK: CARE

Extension 1
(2x Cable S30864-X210-A2)

Extension 2

3-47

CONNECTING
From

To

Base Rack

Extension 1 Rack

Ext. 1 CU 0...3

CU 0...3

Ext. 1 CU 4...7

CU 4...7

CONNECTING
From
Base Rack

3-48

To
Extension 2 Rack

Ext. 2 CU 0...3

CU 0...3

Ext. 2 CU 4...7

CU 4...7

A30808-X3247-G900-01-7618

3.1.5 Grounding

GROUNDING
Ansicht von oben / Top view
Grounding Plate

M6

M8

A30808-X3247-G900-01-7618

1)

Rear side

2)

2)

3)

3)

2)

3)

2)

2)

3)

3)

Base

Extension 1

3)

Front side

Service 2/2

Service 2/1

1) Externer PE-Anschlu mindestens 50mm.


Ext. Ground connection at least 50 mm.
2) Component of MK:EMCR (Cable S30864-X209-A14)
3) Component of Rack

Service 1

Extension 2

3-49

3-50

A30808-X3247-G900-01-7618

PE

b
a

d
c

PE N L L L
123

12 34 5 67

(from EMI-Panel)
(Heater bottom)

(Heater top)
(Heater middle)

EMI-Panel S1

1 23

MK-Power

215/4

MK-Power
AC

215/2

Service 2

215/1

215/3

AC
EMI-Panel

214/4

1)

214/3

214/1

MK-Power
AC

214/2

Service 1

216/4

216/1

MK-Power
AC

216/2

Base

AC-Distribution

216/3

217/4

217/1

MK-Power
AC

217/2

Extension 1

217/3

218/1

MK-Power
AC

218/3

1) Component of MK: CASHS1

218/4

218/2

Extension 2

3.2
Intershelter Cabling

3.2.1 AC Cabling

CABLE
Number

214/1

From
EMI - Panel S1
L3 / 7a
N / 4a
PE / 2a

214/2;3;4
215/1

L1 / 5a
N / 3a
PE / 1a

L2 / 6a
N / 4b
PE / 2b

218/2;3;4

Black1
Black 2
Green/Yellow

Length
(mm)

S30864-X211-A17

Shelter S2 / AC 1b
Shelter S2 / AC 2b
Shelter S2 / AC 3b

Shelter B / AC 1b
Shelter B / AC 2b
Shelter B / AC 3b

L2 / 6b
N / 3b
PE / 1b

Shelter E1 / AC 1b
Shelter E1 / AC 2b
Shelter E1 / AC 3b

Black 1
Black 2
Green/Yellow

S30084-X211-A18

Shelter E2 / AC 1b
Shelter E2 / AC 2b
Shelter E2 / AC 3b
3 x Heatercable an MK

900

---Black 1
Black 2
Green/Yellow

S30864-X211-A19

1300

---Black 1
Black 2
Green/Yellow

S30864-X211-A42

3 x Heatercable an MK
L1 / 5b
N / 3c
PE / 1c

600

----

3 x Heatercable an MK

217/2;3;4
218/1

Code No

3 x Heatercable an MK

216/2;3;4
217/1

Shelter S1 / AC 1b
Shelter S1 / AC 2b
Shelter S1 / AC 3b

Color

3 x Heatercable an MK

215/2;3;4
216/1

To
MK:Power V1

2000

---Black 1
Black 2
Green/Yellow

S30864-X211-A43

2700

----

Connection Heatercable at the MK:Power


Cable 214/2; 215/2; 216/2, 217/2; 218/2
(top)

black1(L)
black 2(N)
green/yellow(PE)

1d
2d
3d

Cable 214/3; 215/3; 216/3, 217/3; 218/3


(middle)

black1(L)
black 2(N)
green/yellow(PE)

1c
2c
3c

Cable 214/4; 215/4; 216/4, 217/4; 218/4


(bottom)

black1(L)
black 2(N)
green/yellow(PE)

1a
2a
3a

A30808-X3247-G900-01-7618

3-51

3.2.2 DC Cabling

3-52

DC-Distribution

Service 2

Service 1

DC-Panel

Base

DC-Panel

Extension 1

DC-Panel

Extension 2

DC-Panel

DC-Panel

2)
1)

3)

4)

4)

MK-Power

A30808-X3247-G900-01-7618

b
1

DC

DC
MK-Power

MK-Power
+0 V

-48 V

DC
MK-Power

DC

DC
MK-Power

MK-Power

221

222

a
EMI-Panel
AC

8x
220

DC

219

EMI - Panel S1
-48 V +0 V -48 V +0 V -48 V +0 V-48 V +0 V

1) Component of MK: CASHS2


b

b b

b b

9 10 11 12 13 14 15

2) Component of MK: CASHS1


3) Component of MK: CASHB
a

S2

E1

E2

4) Component of MK: CASHE

CABLE
Number

From
EMI - Panel S1

219

220

221

222

To

Color

Code No

MK:Power

Length
(mm)

0V

S2 / 9a

Shelter S2 / 1a

Black

-48V

S2 / 8a

Shelter S2 / 2a

Blue

0V

B / 11a

Shelter B / 1a

Black

-48V

B / 10a

Shelter B / 2a

Blue

0V

E1 / 13a

Shelter E1 / 1a

Black

-48V

E1 / 12a

Shelter E1 / 2a

Blue

0V

E2 / 15a

Shelter E2 / 1a

Black

-48V

E2 / 14a

Shelter E2 / 2a

Blue

S30864-X211-A13

900

S30864-X211-A14

1500

S30864-X211-A15

2200

S30864-X211-A16

2900

A30808-X3247-G900-01-7618

3-53

Service 2/3

Service 2/2

Service 2/1

F:AC/DC 1

Service 1

MK:BATTERY
b
1

112/4

112/3

112/2

0V

110/2

111/3

111/2

MK:BAT

MK:BAT

1)

1)
BAT 1

BAT 2
MK:BAT

MK:BAT

BAT 3

BAT 2

BAT 1

F:AC/DC 2
110/1
111/1

T1

T0

14 15 16 17

1)
BAT 1

BAT 0

MK:BAT

1)

1)

112/1

110/4
111/4

T0

F:AC/DC 2

110/3

T0

T1

-48V
T1

F:AC/DC 1

A30808-X3247-G900-01-7618

25 26 27 28

3.2.3 Battery Cabling

3-54

INTERNAL BATTERY INTERFACE


Battery trace

T0

1)
BAT 0

b
T1

+
1) Batterie Entlftung siehe F: Battery
BATTERY BLEEDING SEE F: BATTERY

BAT 2

BAT 3

Battery-Cable
Number

From

2)

To

Factory-No.

Lenght
(mm)

Color

110/1
111/1

S1/F:AC/DC1-26b
S1/F:AC/DC1-25b

S1/BAT 0/ - (-48V)
S1/BAT 0/ + (+0V)

S30864-X211-A46
S30864-X211-A46

1150

Blue
Black

110/2
111/2

S1/F:AC/DC1-28b
S1/F:AC/DC1-27b

S2/1 MK:BAT1 -2a


S2/1 MK:BAT1 -1a

S30864-X211-A47
S30864-X211-A47

2850

Blue
Black

110/3
111/3

S1/F:AC/DC2-15b
S1/F:AC/DC2-14b

S2/2 MK:BAT2 -2a


S2/2 MK:BAT2 -1a

S30864-X211-A48
S30864-X211-A48

3200

Blue
Black

110/4

S1/F:AC/DC2-17b

S2/3 MK:BAT3 -2a

S30864-X211-A49

3500

Blue

2) Kabellnge bei Bedarf anpassen bzw. krzen


IF REQUIRED, ADAPT AND / OR SHORTEN THE CABLE LENGTH

Tempresistor-Cable
Number

From

To

Factory-No.

Lenght
(m)

112/1

Service 1

/ Bat 0(+)

S1/ F:AC/DC 1 T0

S30864-X211-A44

2,5

112/2

Service 2/1 / Bat 1(+)

S1/ F:AC/DC 1 T1

S30864-X211-A44

2,5

112/3

Service 2/2 / Bat 2(+)

S1/ F:AC/DC 2 T0

S30864-X211-A45

5,5

112/4

Service 2/3 / Bat 3(+)

S1/ F:AC/DC 2 T1

S30864-X211-A45

5,5

A30808-X3247-G900-01-7618

3-55

3.2.4 CAN-Bus Cabling

3-56

CAN-BUS- Cabling

Service 2/2

A30808-X3247-G900-01-7618

MK:BUS

Service 2/1

Service 1

Base

Extension 1

Extension 2

CAN IN
CAN OUT
CAN TEST

1)
249

247

245

Achtung: Zuordnung der Kabellgen entsprechend der Ausbaustufe ! Hier: 5 Ausbaustufen: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2
Note: Assignment of the cable lenghts in accordance to the Extension Phase! Here: 5 Phases: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2

246

248

1) Der CAN Bus ist am Ende mit dem Abschluwiderstand S30861-K2047-X abzuschlieen.
(Bestandteil des Base-Shelters)
Lock the bus link S30861-K2047-X at the end with the terminating resisor S30861-K2047-X.
(Component from Base-Shelter)

Verkabelungsbeispiel
Number

From

CABLING EXAMPLE
To

CAN BUS OUT

2)
Code No

Length

CAN BUS IN

245

Base

Service1

S30864-X210-A11

1,2m

246

Service1

Extension 1

S30864-X210-A12

1,9m

247

Extension 1

Service 2/1

S30864-X210-A13

2,6m

248

Service 2/1

Extension 2

S30864-X210-A14

3,3m

249

Extension 2

Service 2/2

S30864-X210-A15

4,0m

2) Achtung: Zuordnung der Kabellgen entsprechend der Ausbaustufe ! Hier: 5 Ausbaustufen: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2
Note: Assignment of the cable lenghts in accordance to the Extension Phase! Here: 5 Phases: 1. Base/Service 1
2. Extension 1;3. Service 2/1; 4. Extension 2; 5. Service 2/2

WS
BL
TK
VI

WS
OR
TK
VI

2
9
5
3
10
-

Signalname

Anschlusspunkt
Connection point

Aderfarbe
Wire color

Vierer

CAN-BUS Steckerbelegung (15-pol.)


CAN-BUS CONNECTOR ASSIGNMENT (15-pol.)

CAN_L
GND
nc
nc
CAN_RESET_L
CAN_GND
CAN_H
nc

Symm. HF-Leitung
09YS(ST)CY 4x2x0,6/1,2-120 GR
V42255-Z1001-A4

A30808-X3247-G900-01-7618

3-57

Base

Extension 1

1)

1)
1) Component of MK: CASHE

(2x Cable S30864-X210-A2)

not connected

not connected
CU 0...3

(Ext.2) CU 0...3
Ext.1 CU 0...3

MK:BUS

CU 4...7

(Ext.2) CU 4...7

A30808-X3247-G900-01-7618

Ext.1 CU 4...7

MK:BUS

Extension 2

3.2.5 SELIC-Cabling

3-58

SELIC- Cabling (CC-LINK -BUS)

CONNECTING
From

To

Base Shelter / MK: BUS

Extension1 Shelter / MK: BUS

Ext 1 CU 0...3

CU 0...3

Ext 1 CU 4...7

CU 4...7

CONNECTING
From

To

Base Shelter / MK: BUS

Extension2 Shelter / MK: BUS

(Ext 2) CU 0...3

CU 0...3

(Ext 2) CU 4...7

CU 4...7

A30808-X3247-G900-01-7618

3-59

Service 2/1

Service 1

Base

Extension 1

Extension 2

A30808-X3247-G900-01-7618

View "A"

1)
3)
2)

2)

2)

2)

View "A"
1) Externer Erdungsanschlu mindestens 50 mm.
Ext. Ground connection at least 50 mm.
Top view

2) Erdungswinkel zwischen zwei Sheltern. (Komponente von MK: EMCIPSH)


Earth angle between two sheltern. (Component of MK:EMCIPSH )
3) Erdungsschrauben werden mit dem Shelter mitgeliefert.
Earthing screws are delivered with the shelter.

Shelter
S1

Shelter
Base

2)

3.2.6 Grounding

3-60

GROUNDING

4.1

HPDU

Mounting Positions Rack

Here the mounting positions of installed HPDUs in one Rack are given. The maximum number of
HPDUs in one rack is two, each for one cell.

HPDU
#0

HPDU
#1

ACOM ACOM ACOM ACOM


#0
#1
#2
#3

RACK

A30808-X3247-G900-01-7618

4-61

4.2

HPDU Cabling Rack

HPDU
#0
RX out

DIAMCO
#0
600

Ant. 0
N-Con. Module 0

SMA

FICOM BASE
#0

Cell 0

TX in

601

HPDU
#1
RX out

DIAMCO
#1
600

Ant. 0
N-Con. Module 0

SMA

FICOM BASE
#1
601

4-62

A30808-X3247-G900-01-7618

Cell 1

TX in

4.3

Mounting Positions Shelter

HPDU
#1

MUCO # 1

MUCO # 0

HPDU
#0

Here the mounting positions of installed HPDUs in one shelter are given. The maximum number of
HPDUs in one shelter is two, each for one cell.

ACOM ACOM ACOM ACOM


#0
#1
#2
#3

Shelter

A30808-X3247-G900-01-7618

4-63

4.4

HPDU Cabling Shelter

HPDU
#0
RX out

DIAMCO
#0
602

Ant. 0
N-Con. Module 0

SMA

FICOM BASE
#0

Cell 0

TX in

603

HPDU
#1
RX out

DIAMCO
#1
602

Ant. 0
N-Con. Module 0

SMA

FICOM BASE
#1
603

4-64

A30808-X3247-G900-01-7618

Cell 1

TX in

5.1

RF-CABLING RACK / SHELTER TO RACK / SHELTER

Cell spread over 2 Racks / Shelter

A RF-Cabling from rack / shelter to rack / shelter is necessary, when one cell is spread over two
Racks / Shelters.
The CUs of the extension rack / shelter are connected to their DIAMCO. The DIAMCO of the base
rack / shelter has to be connected to the DIAMCO in the base Rack / shelter.
This cabling can be done in the case of base to extension and extension to extension.

Note:
Until now, in the case of RF-Cabling from BTS to BTS, the racks / shelters must be installed
side by side.

Cabling

DIAMCO
700

N-Con.

Ant. 0
Module 0

Module 0

Ant. 0

DIAMCO

RXCA SMA
N-Con.

Ant. 1
Module 1

Ant. 1

RXCA
7001)

Module 1

5.2

RXCA SMA

RXCA

Base Rack / Shelter

Extension Rack / Shelter


Rack / Shelter border

1) This cabling is necessary because of antenna diversity.

A30808-X3247-G900-01-7618

5-65

LIST OF ABBREVIATIONS
-A-

AC/DC
ACOM
ACT

AC/DC Converter
Antenna Combining
Alarm Collection Terminal

-BBAT
BS 240
BS 241
BTS
BTSE
BTSEplus
BTSplus

Battery
24 Carrier BTSE, Indoor
24 Carrier BTSE, Outdoor
Base Transceiver Station
Base Transceiver Station Equipment
Base Transceiver Station Equipment second Generation
Base Transceiver Station second Generation

-CCASHB
CASHE
CASHS
CU

Cabling Shelter Base


Cabling Shelter Extension
Cabling Shelter Service
Carrier Unit

-DDCP
DIAMCO
DUAMCO

DC Panel
DI-Amplifier Multicoupler
Duplexer Amplifier Multicoupler

-EEMI
ETS

Electro Magnetic Interference


European Technical Standard

-FF
FICOM

Frame
Filter Combiner

-HHPDU
HU

High Power Duplexer


Height Unit

-MMK:
MUCO

6-66

Mounting Kit
Antenna Multicoupling

A30808-X3247-G900-01-7618

-RR
RB
RCAP
RE
RF
RS
RSHB
RSHE
RSHS
RX
RXAMCO
RXCA
RXFIL

Rack
Rack Base
Rack Cabling Access Panel
Rack Extension
Radio Frequency
Rack Service
Rack / Shelter Base
Rack / Shelter Extension
Rack / Shelter Service
Receive
Receiver Antenna Multicoupler
Cascading output for the receive path
Receive Frequency Bandpass Filter

-SSBS
SCAP
SH

Siemens Base Station


Shelter Cabling Access Panel
Shelter

-TTMA
TX

Tower Mounted Amplifier


Transmit

A30808-X3247-G900-01-7618

6-67