T
140
60.0
0.485308203
2.035
0.203
19.955
2.89
6.69
b
hvap
site elevation
0
0.0
101325.0
14.70
hatm
Mixture S.G.
4.500
1.9481
3.0687
1.3284
hf
NPSH_A =
m H2O
kg/cm2
kPa(a)
psi(a)
ft
m
ft
Pa
psi(a)
hf =
p*v*di/n
f * (L * v^2)/(2* di)/g
0.9353
3.0687
1.3284
9.159169715
Lequiv
13D
20D
20D
65D
64D
32D
7
1.3208
0
1.016
0
3.2512
1.6256
14.2136
where
p=
v=
di =
n=
1000
1.9246
0.0508
0.001002
m
ft
psi(g)
kPa(g)
3.355605 in
0.002165 m
L or Lequiv
2
0
1
0
1
1
97577
0.002
3.93701E-05
0.0177
ft
psi(g)
ft
psi(g)
15 m/hr
2
40 Area
0.0508 m
quantity
pipe length
2" gate valve
2" elbow
2" tee (straight)
2" tee (branch)
pump inlet
tank outlet nozzle
total
Re =
e=
e/d =
f=
ft
psi(g)
ft
psi(g)
hs - hf + (hatm - hvap)
12.421 psi(g)
28.69 ft
8.75 m
Pump Flow
Line diameter
Re =
NPSH_A =
F
C
m
m
m
m
m
m
m
m
kg/m
m/s
m
Ns/m