Vous êtes sur la page 1sur 14

SANYO ELEVATORS AND ESCALATORS CO.LTD.

ELECTRIC DRAWING
(Villa lift-NICE 1000-220V single phase)

SANYO ELEVATORS AND ESCALATORS CO., LTD.

24V X22
Main Power Switch (By others) Main Power Switch 7 8 L1 L2 Security contactor

K(2P20A) LA L1 N PE

Q(2P20A) R S R1 S1

PT
R/L1 S/L2 T/L3 U V W
1 3

KJT 2 KJT 4 3 1

KDY 2 KDY 4 KDY 5 6


Running Contator

R S

U3 V3 W3

Motor

AC220V

LB/LN PE

EPS

Nice 1000

12V
C

+12V 0V A B
C

PGM

CN2

PGA PGB

PG

PE

PB

RZD

Braking Resistor

+
B B

PE

Design Qian Jianqiang Check Approve Date


2013.10.1

Main Circuit

Draw No. TRM512 5 Sheets 1A Sheet Remark

SANYO ELEVATOR AND ESCALATOR


1 2 3 4 5 6 7 8

24V X22
Main Power Switch(by others) Main Power Switch 7 8 L1 L2

K(2P20A) LA L1 N PE

Q(2P20A) R S R1 S1

Security contactor KJT 2 KJT 4 3 1

PT
R/L1 S/L2 T/L3 U V W
1 3

KDY 2 KDY 4 KDY 5 6


Running Contactor

R S

U3 V3 W3

Motor

AC220V

LB/LN PE

EPS

Nice 1000

C MCTC-PG-E

CN1

PG
1387

PB

RZD

Brake Resistor

+
B B

PE

Design Qian Jianqiang Check Approve Date


2013.10.1

Main Circuit

Draw No. TRM512 5 Sheets 1B Sheet

SANYO ELEVATOR AND ESCALATOR


1 2 3 4 5 6 7 8

F3(1P4A)
R1
200

S1
D

201
D

F4(1P4A)

Door Lock Contactor

Running Contactor Brake Contactor

KMS
1 2 44

KDY 43

KLZ
2 1

ZL1 AC + AC
4

KLZ
3

Note: when brake voltage is DC200V, add rectifier ZL1 when brake voltage is AC220V, jump it.
Brake

LZ BK1 BK2

F4(1P4A)
C

Brake Voltage: AC220v/DC200V


103+
C

TC1

AC220V/5A DC110V/2A AC110V


nd ir aa mo nb ol 3o Nr Ct n oo Tc
102-

Controller Transformer

AC0V
101
A2 Door Lock Contactor KMS Safety Contactor KJT A1 A1 A2

XCM

100a

SM1
Landing Door Lock on 1st floor

X25

116

SM2
Landing Door Lock on 2nd floor

SJT Emergency Stop in M.R. Safety Circuit 115a SPS Handwheel Switch SMJB
Car Door Lock Switch

SMJ SM3 Car Door Switch

115

110

GJ DJ Emergency Electric

Operation Inspection on Car Top

SCS Up Overspeed Switch SMn-2


Door Interlock Circuit

114a SKS Rope Breakage Switch SXS Speed Governor Switch

SMn-1 114

Landing Door Lock on N floor


A

SSJ Top Final Limit 108 113 SXJ Bottom Limit


A

SMn

117

X26 SHCBuffer Switch To CN3 on Main Control Board

109

XXV1

Inspection Bottom Limit


1 2 3 4 5 6

n id ar ma o nb o l 3o Nr Ct n oo Tc

d r a o b l o r t n o c n i a m n o 3 N C o T

X27

118

F2(1P4A)

100 SDT
Emergency Stop on Car Top
B

SPC Car Top Bolt Switch

Door Lock Contactor

Running Contactor Brake Contactor

KMS
1 2 44

Optional
106

KDY 43

KLZ
2 1

BK1

Brake

BK2

LZ D1

Brake Contactor KLZ 4 3

SKT
Emergency Stop in Pit

RLZ

Applicable when traction machine doesn't have brake discharge circuit

Brake Voltage: DC110v

111 SNQSafety Gear Switch

Design Qian Jianqiang Safety Circuit Check Door Lock Circuit Approve Date
2013.10.1

Draw No. TRM512 5 Sheets 2 Sheet Remark

SANYO ELEVATOR AND ESCALATOR


7 8

GND1

+24V
1

129 GJ

Emergency Electric Operation 3 1

X4
2
Jog Up

138

ES1
130

S1 X5
3

L13
DJ 118 139
Jog Down

HF70W-D

FMS FMX

SH1
2 1

24V+

M1
101 M2
5

24V

+24V

200 L Power Unit 24V-

X6

ES2 S2 KMS

COM: FMG in M.R.

Inspection on Car Top

L14
KLZ Brake Contactor
A1 6

COM

GND1

201 N
2

SH2 YKJ
21 22 A2

To be connected when there is electric brake release function

DMS DMX

Jog Up (Car Top) Jog Down (Car Top)

COM: DMG on Car Top

Y1

ES3 S3

L15
SMQ X1 KDY
31 32

SH3 Door Zone


A2 A1

125
Running Contactor KM1 Door Open 1

KDY Running Contactor Y2 N1 L5 Car Call 1 SN1 EN1

ES4 S4

X2 L16
KLZ

SH4

X3 127
SXF Fireman Switch CXF
to be connected when there is fire inter-action

43

44

Brake Contactor

Y6 GM1 Door Close 1

L6

Car Call 2 N2

EN2 SN2
3

EX2 X2

X7 L17 128

Y7 KM2 Door Open 2 Y8 GM2 Door Close 2 CM1 COM YM1 L7 Car Call 3 N3 EN3 SN3

XH2

EX3 X3

X8 L18 121
X9

SDF Eletric Lock (locked when closed)

Y9 L8

XH3

Top Limit Inspection Top Limit SXV 121a SXV1 Bottom Limit Inspection Bottom Limit XXV 122a XXV1

Car Call 4 N4

EN4 SN4

122
EX4 X4 X10

Car Call 5 N5

EN5 Top Terminal

L19 123
X11

XH4

SDZ

a Y10 b
XDZ Bottom Terminal

L9 SN5

124
X12

Y11 c Y12
L10 Car Call 6 N6 EN6

EX5 X5

L20
X13

XH5

145 146 X14

SCZ

Overload Switch

SN6

SBZ SZH

Half Load Switch

JX + -

BCD Code Indicator (com"-")

Y16 150 X15


By attendent (effetive when open)

Y19
+24V

Microprocessor Controller

Microprocessor Controller

5 6

Door Open 1

L1 132
X16 KMV1 Door Open Limit 1 ES UP 45

152
Door Close 1 153

SKM1

SGM1

Y17 133
X17 GMV1 Door Close Limit 1 EX Down 46

L2 Y18 134 X18 137 X19 135


KAB1 Safety Edge 1 BEL Arrival Gong BL1

L3

154

SKY Door Open Holding

Y20
Black

KAB2

Safety Edge 2

Yellow Red

Design Check Approve Date


2013.10.1

X20 X21 X22

KMV2 Door Open Limit 2

+24V

136

GMV2 Door Close Limit 2

FMQ
8 7

Buzz EPS UPS Running Signal

44

Y21
ECZ Overload Light 47

Qian Jianqiang

X23
7 8

13

14

Y22
7

KJT Emergency Stop Contactor Detecting

to be connected when there is fire inter-action

YM2

X24 +24V 24V

14
KMS Door Lock Contactor Detecting

KXFL 13
KXFL LD1
5 9

Y23
LD2

Input & Output Circuit


Draw No. TRM512 5 Sheets 3 Sheet Remark
A

YM3

14 KZM

SANYO ELEVATOR AND ESCALATOR

13
Car Light Relay GND1

Y3

M3
+24V GND1
8

U Motor V W L

U5 V5 W5 Motor

U6

Motor

V6 W6

Motor

200

200

Power

VVVF Door Operator

201

VVVF Door Operator

Power N PE
Open Limit Close Limit COM B2 B3

201

132 133 +24V KM1 GM1

Open Limit Close Limit COM

135 136 +24V KM2 GM2

C2/C3

Open Signal

Open Signal

Close Signal

Close Signal

COM 8

CM1

COM

CM1

Main Door

Sub-Door

Design Check Approve Date

Qian Jianqiang

Door Circuit
2013.10.1

Draw No. TRM512 5 Sheets Sheet 4 Remark

SANYO ELEVATOR AND ESCALATOR


1 2 3 4 5 6 7 8

L31

NZ
Car Top Switch

201 Remote Reset Device of Governor


DC110V output

SDM
EPSS-EPB110
DC12V output J3 J4 J5 J6 P1 P2 P4 P5 P6 P7

L311 Car Top Light


Car Top Light Socket

EDM
D

200 FXS XS2 XS1


R1 S1 BK1 BK2
220V input J1 J2 Yellow Terminals

XD EKM XK

Pit Light Switch

SKK

L312

Pit Light Pit Light Socket

Jump it for use

21

KJT +

+24V 125

22

Control Cabinet Socket

XJ

116

118 KZM

3 11

Governor Action

Governor Reset

L33
Power DC12V

Car Light Switch

SJM

EM

Car Light

EM1 EM2

C Video Cable

Car Fan Switch

SFA
To monitor machine in shaft

Car Fan

FAN

LCD indicator in Controller

Applicable for MRL elevator

Applicable for MRL lift with EMK electric brake release and machine monitor function

Q
L1
Light Leakage Protection 10A

Q1

L31

Car Light Breaker (1P4A)

(Safety 5-party Intercom)


Emergency Power Box Alarm Light AC220V
B
Alarm

L2/N

NZ

Intercom

Machine Room

Car Top

Pit

Guard Room

Car Blue Red Black Yellow

Q2
L32
Hoistway Light Breaker (1P10A)
B

+ -

+ EYJ

+ -

R L

R L

R L

R L

NZ
P2+ P2-

JL2

SJL
JL1

L32 Hoistway Light Switch(M.R.)

L31 NZ
AC220V

SZMf

L32A

Hoistway Light (Pit)

SZMk

NZ ECM1
Hoistway Light

L32B L35 Hoistway Light by Others

ECMn

Qian Jianqiang Design Control & Light Check Circuit Approve

Date

2013.10.1

Draw No. TRM512 5 Sheets Sheet 5 Remark

SANYO ELEVATOR AND ESCALATOR


1 2 3 4 5 6 7 8

200

Top Final Limit Switch


D

SSJ
100
D

Top Limit Switch

SSV

Top Terminal Switch

SSD

*1

200

Bottom Final Limit Switch

SXJ

Bottom Limit Switch


C

SXV
100
C

Sub Bottom Terminal Switch

Bottom Terminal Switch

SXD
*1
Leveling Position

Leveling Switch (Unit:mm)

MQ
SMQ Shelter Board

Car

200 UP
B

DOWN
B

Hoistway learning must be done before elevator high-speed running. Elevator must have the following conditions before hoistway learning 1Top/Bottom limit switch,Top/Bottom terminal switch are installed and wired correctly. 2Upper/Lower leveling switch and shelter boards on every floor are installed and wired correctly. 3Safety circuit and door interlock circuit are normal. 4General parameters and running parameters are set properly. 5Elevator can run in inspection mode normally.

Speed

10mm

Item *1

0.3m/s 500

0.4m/s 650

Bistable switch and magnet installation position

Date Page 7 2013.11.1


1 2 3 4 5

Page No. TRM512----Control cabinet plug-in and terminal 1 SANYO ELEVATOR AND ESCALATOR
6 7

Qian Jianqiang Design Audit Remark

Approve
8

Terminal TB1
No. Symbol

Small Terminal TB2


No. Symbol

1 2 3 4 5 6 7 8 9
10

L1 N R S
U3 V3 W3

1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17

BK1 BK2 114 114a 100 115 115a 116 117 118 130 121 122 P2+ P2R

Brake V Speed Governor GC-1 1 10 24V 130 145 134


GND1 138
3

Safety Circuit Handwheel Switch Car door interlock Hall


24V

GC-2 1 10 CM1 135 BL1 . .R KM2 136 P2+ . . GM2 137 P2.
3 1

GC-2A 1 10 100 111 200 NZ 108 116 201 PE 110 117 L31 PE

132 KM1
12 10

125 139 133 GM1 GC-3 150 154 N3


1

.
12 10

3 1

12

N6 A B
12 10

C D JX
3 1

GC-4 - 47 45 44

L33 PE
12 10

N7 N8 N9
3 1

GC-4A . . .

10

. . .
12

11 24V

152 153
3 1

N1 N4 N2 N5 GC-5

Inspection
24V

46 106 PE

Applicable for above 6 floors

Limit switch Intercom power

24V B
GND1 C

45 46

S1 127 128
12 10

GC-6 24V 106 113 124 108 P23 1

R PE
12 10

GC-7 10 24V 113 PE L32A 121 114 117 L32B 123 PE


3

122 111 P2+ PE

A
3 1

JX

118 NZ
12

18 LD1 19 LD2 20 127 21 22 23 24 25 26 L31 27 L33 28 NZ

Fire emergency action

X2 S2 X3
3

GC-5A S3 X5 X4 S5 S4 X6

GC-5B . .

S6 X7 S7
12

X8 S8 X9
3

Applicable for above 7 floors


12

If they are wired in terminals, they are no need to be connected again. Port Layout of Socket in Controller
The connector in the controller is socket (female), the connector on cable is plug (male)

Car light

29 L32A
30
L32B

Shaft light

Date Page 2013.11.1 7

Page No. 2

TRM512----Control cabinet plug-in and terminal

SANYO ELEVATOR AND ESCALATOR

Design Audit Remark

Approve

Q
Door Zone

Controll Cabinet

Car Top Terminal box


Slow Up

SMQ

Car Top Traveling Cable CB1(36core)


DC-1
GC-1
Dwg No.Wire No. Pin No. Dwg No.Wire No. Pin No. Dwg No. Wire No. Pin No.
Car Top Inspection

24V 138 125 100 SDT Car top stop button

Connector wiring DC-1 1 10 24V 130 145 134


GND1 138
3 1

130 24V

SDS

24V Yellow1 1 GND1 Yellow2 2 125 130 138 139 145 132 133 134
Yellow3 Yellow4 Yellow5 Yellow6 Yellow7 Yellow8 Yellow9

CM1 KM2 GM2 135 136 137 BL1 P2+ P2R

White1 White2 White3 White4 White5 White6 White7 White8 White9

1 2 3 4 5 6 7 8 9 11 12

100 108 110 111 116 117 200 201 L31 NZ PE PE

Orange1 Orange2 Orange3 Orange4 Orange5 Orange6 Orange7 Orange8 Orange9

1 2 3 4 5 6 7 8 9 11 12

SZD 3 2 1

COM

Slow Down

SDX SDG

139

DC-2 1 10 CM1 135 BL1 R KM2 136 P2+ GM2 137 P23 12

3 4 5 6 7 8 9

DC-2

GC-2

105

132 KM1
12

SZD 110
4 5

125 139 133 GM1


111 SNQ Safety gear switch 108 EDM
Car Top Light PE XD Car top socket

GC-2A

DC-2A

Emergency electric

DC-2A 10 100 111 200 NZ 108 116 201 PE


EM1 EM2
Car Light

Car top light switch

SDM

L311

L31

NZ EM

110 117 L31 PE


3 12

Yellow10 10

White10 10 White11 White12

Orange10 10
Orange11 Orange12

KM1Yellow11 11 GM1Yellow12 12
Operation Board

NZ L31
Input Power AC220V

FA

FAN Car Fan


Car ceiling interphone

DY
Emergency Power Supply for Intercom

DC-6 1 10 24V P 2- 105 P+


GND1 JL1
3

InterphoneOutput +

DC-6

PC-1

Car operation board cable CB3 12core 4.5M

PEmergency light P+ Car Emergency light + output


Alarm Output +

EYJ

P2+ P2R

FA

P12

+ R

R JL2 EM

Car Top Terminal Box are with female socket, Cable are with male plug
HJ Applicable for rear door operator if any
(cable in door operator) CB2-B1 Sub-door operator cable1

JL1

JL2

Alarm button in car Alarm

(cable by door operator own) CB2-A1 Main Door Operator cable1

116 Inverter 1 2 8 C2/C3 B2 B3 (6core) KM1 GM1 CM1 24V 132 133 Dwg No.

Terminal Blocks

Wire No. 1

Main Door Lock

1 Wire No. (6core)Inverter 1


Dwg No.

2 2

6 DB1

Car Top Terminal DB


DB2 DB3 DB4

8 C2/C3 B2 B3

Terminal Blocks

116a 117

KM1 GND1 GM1 CM1 (cable by door operator own) 125 CB2-B2 door operator cable2
KM2 GM2 CM1 24V 135 136

24V

P2+ P2R JL1 JL2 105 FA EM NZ L31

100 108 110 111 116 117 200 201 P+ P-

(cable by door operator own) CB2-A2 Main Door Operator cable2 (3core) Wire No. 1 2
Yellow Green

Wire No. 1

2 N

Yellow Green

(3core)
Inverter L

130 138 139 145 132 133 134

KM2 GM2 135 136 137 BL1

Vice Door Lock

PE

Inverter L

PE

Dwg No.200 201 PE

200 201 PE Dwg No. (6core) CB2-C1 Main door light curtain cable 3M Wire No. 1 light curtain Dwg No. 200 201 PE 24V 134 2 3 4 5 6 (6core) CB2-C2 Sub-door light curtain cable 3M 2 3 4 5 6
Wire No. 1 Light curtain Dwg No.200 201 PE

24V 137

Date Sheet 2013.11.1 7

Page No. TRM512----Car Ceiling Circuit SANYO ELEVATOR AND ESCALATOR 3

Design Remark

Audit

Approve

CB4(24/36core)
Dwg No, Wire No.Pin No.

COP in the Car


BELbuzzer

Socket & Plug Layout


1

Flat Cable from Controller to COP

150 152 153 154 N1 N2 N3 N4 N5 N6 A B C D JX

Yellow1 Yellow2 Yellow3 Yellow4 Yellow5 Yellow6 Yellow7 Yellow8 Yellow9 Yellow10 Yellow11 Yellow12 White1 White2 White3 White4 White5 White6 White7 White8 White9 White10 White11 White12

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6

Car Top Junction Box to COP

44 GND1 24V 45 46 47 A B C D P2-

SA7
0V

7Floor N7

24V
GND1

PC-1 10 P2- 105 P+ JL1 FA JL2 EM


12

P-

24V UP
DOWN

R
3

SA6

6Floor

CZ A B C D red

N6

CB3(12Core)
Dwg No. Wire No.Pin No. Yellow1

overload

SA5

5Floor

N5

24V R P2-

1 3 4 5 6 7 8 9 PC-3 150 154 N3


1 10

yellow

GND1 Yellow2 2
Yellow3 Yellow4 Yellow5 Yellow6 Yellow7 Yellow8 Yellow9

PC-1

SA4 R Black
Interphone

4Floor

N4

N6 A B
12 10

Entry at bottom

Orange SA3 3Floor N3

152 N1 N4 153 N2 N5
3 1

Entry at bottom

JL1 JL2 105 FA EM P+ P-

when use Jingke Interphone

Interphone Switch

C D
3 1

PC-4 - 47 45 44

L33 PE
12

PC-3

45 46 47 44 106 L33 PE PE N7 N8 N9

EYJ PP+ Emergency lamp SKM Open door button

SA2

2Floor

N2

Yellow10 10 Yellow11 11 Yellow12 12

JX 46

106 PE
10

PC-4

152

SA1

1Floor N1

N7
Instruction:

PC-4A . . .

. . .
12

N8 N9
3

PC-4A

153 GND1

SGM Close door button SZH Delay closing door


Fan Switch

24V PE 154
COPiswith3nos.socketof12pineach.(femalconnector) Cableentryshouldbeatthebottom(whenfloor/stopismore than6,PC4Awillbeadded)

Orange1 Orange2 Orange3 Orange4 Orange5 Orange6

SFA
Light Switch

105 FA EM

SJT

Stop Button

COP is with female socket, Cable is with male plug If COP is handrail type, please extend the connector to outside, length is 2m.

106

L33

SJM

SSJ

Driver

24V

150

Remark: when floor no. is more than 6 floors, we change it to 36 core flat cable

Date sheets Page No. TRM511----Operator Pannel circuit SANYO ELEVATOR AND ESCALATOR 4 2013.11.1 7

Design Audit Remark

Approve

Hoistway CableCB5-1

Hoistway Cable CB6 Plug Cable Terminal No. in one end Pin No Dwg No. Wire No. No. Length

Hoistway CableCB7-1 / CB8 Plug Cable Terminal No. in one end No. Length Pin No. Dwg No. Wire NO.

GC-5 Control CabinetGC-5A/GC-5B


12 core CB5-7 2core 2core

GC-6
12core

Control Cabinet

GC-7
7 coreL35 ECMn NZ

Plug Pin NoDwg.No

Wire No.

1 2 3 4 5

24V A B C JX

1 3 4 5

1 2 3 4 5

24V 122 124 106 111 108 113 P2+ P2R PE PE

1 2 3 4 5 6 7 8 9

24V 122 124 106 111 108 113 P2+ P2-

1 2 3 4 5

24V 121 123 113 114 PE PE 117 118

1 2 3 4 5
Yellow Green Yellow Green

24V 121 123 113 114 PE PE

Branch wire 3core1 root/2 core 2 root

GND1 2

HC-J1

HC-7

24V 113 SSJ 114 24V PE

SXV 121 SDZ 123

117 SMn SMn

GC-5

6 7 8 9

GC-6

6 7 8 9 10 11 12

6 7 8 9 10 11 12

GC-7

6 7 8 9

L35

ECMn-1 NZ

45 46

CB5-1

CB5-2

CB6

CB8

XH7

7 Down

Top Final Limit Switch Cable

SMn

SMn-1 SMn-1

10 S1 11 127 12 128

10 R 11 PE 12 PE

10 L32A 3 L32A 11 L32B 4 L32B 12 NZ L35 5 6 NZ L35

108 SXJ 109 24V PE 24V

XDZ 124 XXV 122

Pit Inspection Box

HC-J1

HC-2

Wiring No.

Branch wire 3 core1 root/2 core2 root Bottom Final Limit Switch Cable
Jingke Intercom

106
R

P2+ SH2 2 Up P2-

106a 108 109 L32A L32B L35 NZ


L35 ECM2 NZ

Pit Branch Cable 3Core Cable Terminal No. in two end


Core No.
Dwg.No Wire No.

Hoistway Calling Cable

(CB5-2~CB5-7)
Dwg No. Wire No. Pin No.Plug

No. Length

111 111

1
Yellow Green

111 24V 113 109 5M PE

1 2

1 3 4 6

Inspection Box in Pit


XH2 2 Down
Pit Stop Button

R 111 106a 109 113 PE L35 SHC


Buffer Switch Cable

SKS
Tension Pulley Switch Cable

113 111 P2+

106a 106a PE PE 113 113

2 106a 3M

S2~S8

SKT 106 SKT1 106a


Pit entry stop button

SM2 SM2 SM1

P2R

1 2
Yellow Green

109 109 PE PE

ECM1

NZ
Remark: 1. If there are two opposite entrance on one floor or all floors, the branch cable for HOP at sub-door side should be
connected to the branch cable of HOP at main door side in parallel. (length:4M) 2. If there are two opposite entrance on one floor or all floors, branch cable for sub-door lock should be connected to main door lock in serial, length 6M. 3. Brach cable for door lock is 3M , branch cable for light is 2M. HOP is with female socket, Cable is with male plug

HC-1

NZ SM1 SM1 118 EKM


Pit ganged switch

XK

SH1

1 Up

L32A SZMK L35 L32B Date Sheets Page No.

Hoistway Calling System

Design Audit Remark

Approve

2013.11.1

SANYO ELEVATOR AND ESCALATOR

HC-2~HC-7

X2~X9

Remark

Highway10M Branch3M

Main Wire 6core 1root

Hoistway Total High+6M Branch3M

CB7-1

7TH
45 46
A B C D

6TH

3TH

2TH

1TH

DOWN

UP

A B C D

Inspction JX

+24 0V

GND1 24V

S6

SH6

GND1 24V

S3

SH3

GND1 24V

S2

SH2

GND1 24V

S1

XH7

GND1 24V
SYD

X7

XH7

GND1 24V

X6

XH6

X3

XH3

X2

XH2

128 127

SCF

24V
GND1

HC-J1 B C JX 45 46

10

HC-7 . X7
1

24V
GND1

HC-J1 B C 45 JX 46

10

HC-6 . X6
1

24V
GND1

HC-J1 B C 45 JX 46

10

HC-3 X3 .
1

24V
GND1

HC-J1 B C 45 JX 46

10

HC-2 X2 .
1

HC-1 B C JX

10

24V
GND1

S1

45 127 . 46 128 .
12

A
3

.
12 3 6

A
3

S6 .
12 3 6

A
3

. S3
12 3 6

A
3

. S2
12 3 6

A
3

CB5-1 CB5-7 CB5-6 CB5-3 CB5-2

Date Sheet Page No. TRM512---Outbound Circuit SANYO ELEVATOR AND ESCALATOR 6 2013.11.1 7

Design Audit Remark

Approve

24core
Wire NO. Pin NO. DWG.NO

Deputy operation board in the car


BELbuzzer 44 GND1 24V 45 46 47 A B C D SA7
0V

Main COP In the car

24v 152 153 N1 PC-5

Yellow 1

1 3 4 5 6 7 8 9

7floor N7

GND1 Yellow2 2
Yellow3 Yellow4 Yellow5 Yellow6 Yellow7 Yellow8 Yellow9

24V UP
DOWN

SA6

6floor

PC-5

24V

PC-5 153 N3 N4 N5

10

N2 N3 N4 N5 N6 PC6 N7 N8 A B C D

N6 N7 N8
12 10

CZ A B C D

N6

Overload

SA5

5floor

N5

GND1 N1

152 N2
3 1

Yellow10 10 Yellow11 Yellow12 White1 White2 White3 White4 White5 White6 White7 White8 White9 White10

SA4

4floor

N4

A B C
3

PC-6 46 D

PC-6

11 12 1 2 3 4 5 6 7 8 9 10 11 12
GND1 153 SGM door close switch Manufacturing instructions: When connect plug-in wire,deputy COP raises 24 core cable, wire length is 6m,using two 12pin connector plug(using 1-480704-0 ample 12pin connector plug with 350218-1) 24V 152 SKM door open switch SA1 1floor N1 SA2 2floor N2 SA3 3floor N3

45

47 44 PE
12

45 46 47 44 Manufacturing instructions:
When there is deputy COP in the car

White11

PE

White12

main COP add 12pin connection socket(female)


1

24V

PC-5 153 N3 N4 N5

10

N6 N7 N8
12

A B C
3

PC-6 46 D

10

GND1 N1

45

47 44 PE
12

152 N2
3

Date Page 7 2013.11.1

Page No. 7

TRM512----Control cabinet plug-in and terminal

SANYO ELEVATOR AND ESCALATOR

Qian Jianqiang Design Audit Remark

Approve

Vous aimerez peut-être aussi