Vous êtes sur la page 1sur 1

2EC403_Microwave Engineering

NIRMA UNIVERSITY
INSTITUTE OF TECHNOLOGY
B.Tech Semester VII (EC)
2EC403 MICROWAVE ENGINEERING

Assignment 3

1. A metal box is 3 x 4 x 5 cm in dimensions filled with air. Calculate the resonant
frequency of the cavity for TE
102
.

2. A rectangular waveguide of cross-section 5 cm x 2 cm is used to propagate TM
11
mode at
10 GHz. Determine the cut-off wavelength and the characteristic impedance.

3. A rectangular air-filled copper waveguide with dimension 0.9 inch x 0.4 inch cross
section and 12 length is operated at 9.2 GHz with a dominant mode. Find (a) cut-off
frequency (b) guide wavelength (c) phase velocity (d) characteristic impedance and loss.

4. An air-filled rectangular cooper waveguide of cross-section 0.9 inch x 0.4 inch is
operated at 10 GHz. Calculate the attenuation constant in dB/m. Find the frequency and
attenuation at which the attenuation is minimum for TE
10
mode.

5. An air -filled X-band waveguide (0.9 inch x 0.4 inch) is fed from a signal source at 6
GHz. Calculate the wave impedance. Explain about the characteristic of single
propagation through the guide.

6. Design a rectangular waveguide with filling by a dielectric of 4
r
, so that the cut-off
frequency for the dominant mode is 14 GHz and the cut-off frequency for the TM11
mode is 30 GHz.

7. Calculate the coupling factor of a directional coupler when incident power is 600 mW
and power in auxiliary waveguide is 350 watt.

8. For a directional coupler the incident power is 550 mW, calculate the power in the main
arm and auxiliary arm. The coupling factor is 30 dB.

9. Incident power to a Directional coupler is 90 watts. The directional coupler has coupling
factor of 20 dB, directivity of 35 dB and Insertion loss of 0.5 dB. Find the output power
at main arm, coupled and isolated parts.

Vous aimerez peut-être aussi