Vous êtes sur la page 1sur 2

Model: 3196 Size: 2X3-13 Group: MTi 60Hz RPM: 1770 Stages: 1

Job/Inq.No. :
Purchaser : UNDEFINED
End User: Issued by :
Item/Equip.No. : ITEM 001 Quotation No. : Date : 05/20/2014
Service :
Order No. : Rev. : 0
Operating Conditions Pump Performance
Liquid: Water Published Efficiency: 64.5 % Suction Specific Speed: 6,330 gpm(US) ft
Temp.: 70.0 deg F Rated Pump Efficiency: 64.5 % Min. Hydraulic Flow: 57.5 gpm
S.G./Visc.: 1.000/1.000 cp Rated Total Power: 17.2 hp Min. Thermal Flow: N/A
Flow: 364.0 gpm Non-Overloading Power: 19.4 hp
TDH: 120.0 ft Imp. Dia. First 1 Stg(s): 11.8750 in
NPSHa: 0.0 ft NPSHr: 8.0 ft
Solid size: Shut off Head: 147.9 ft
% Susp. Solids
(by wtg):
Vapor Press: Max. Solids Size: 0.3750 in
Notes: 1.The Mechanical seal increased drag effect on power and efficiency is not included, unless the correction is shown in the
appropriate field above. 2. Magnetic drive eddy current and viscous effect on power and efficiency is not included. 3.
Elevated temperature effects on performance are not included. 4. Non Overloading power does not reflect v-belt/gear
losses.
Model: 3196 Size: 2X3-13 Group: MTi 60Hz RPM: 1770 Stages: 1
Job/Inq.No. :
Purchaser : UNDEFINED
End User : Issued by : Rev. : 0
Item/Equip.No. : ITEM 001 Quotation No. : Date : 05/20/2014
Service :
Order No. :
Operating Conditions Pump Performance
Liquid: Water Published Efficiency: 64.5 % Suction Specific Speed: 6,330 gpm(US) ft
Temp.: 70.0 deg F Rated Pump Efficiency: 64.5 % Min. Hydraulic Flow: 57.5 gpm
S.G./Visc.: 1.000/1.000 cp Rated Total Power: 17.2 hp Min. Thermal Flow: N/A
Flow: 364.0 gpm Non-Overloading Power: 19.4 hp
TDH: 120.0 ft Imp. Dia. First 1 Stg(s): 11.8750 in
NPSHa: 0.0 ft NPSHr: 8.0 ft Shut off Head: 147.9 ft
Solid size: Max. Solids Size: 0.3750 in % Susp. Solids
(by wtg):
Vapor Press:
Notes: 1. The Mechanical seal increased drag effect on power and efficiency is not included, unless the correction is shown in the
appropriate field above. 2. Magnetic drive eddy current on power and efficiency is not included. 3. Elevated temperature
effects on performance are not included. 4. Non Overloading power does not reflect v-belt/gear losses.