Académique Documents
Professionnel Documents
Culture Documents
Anexo N 3, Pgina 2
LARGO
1,266.0 m
Clculos Previos
Punto
Distancia
Acum (m)
Datos de Salida
Cota Piezomtrica (m)
Cota de
Radier
Trabajo
Mxima
Mnima
Trabajo
Presin (mca)
Mxima
Mnima
464 m/s
0.00
776.55
790.45
677.40
656.15
120.40
134.30
21.25
Diam. Int.
93.6 mm
1.55 m/s
126.60
773.04
789.10
679.02
652.66
120.38
136.44
26.36
N SECC.
10 N
0.007 m2
253.20
769.52
787.75
680.78
653.76
115.76
133.99
27.02
6,763.85 s/m2
379.80
766.01
786.27
682.46
654.86
111.14
131.41
27.60
140 HW
a/(g*A)
K(agua)
20,600 Kg/cm2
0.0262
506.40
762.49
784.93
684.20
665.57
96.92
119.36
18.63
E(PVC)
28,100 Kg/cm2
0.0200
633.00
758.98
781.12
689.69
676.77
82.20
104.35
12.92
126.60 m
759.60
755.46
775.94
696.81
687.74
67.72
88.20
9.07
886.20
751.95
769.07
705.78
698.08
53.86
70.99
7.70
Dx
CAUDAL
Ho
10.64 l/s
8.20 mm
120.38 m
R 28,166.68
Dt
0.273 s
1,012.80
748.43
760.78
716.37
708.59
39.84
52.19
7.78
Tcritico
5.457 s
1,139.40
744.92
751.42
728.36
714.83
30.09
36.59
13.53
Tcierre
3.274 s
1,266.00
741.40
741.40
741.40
741.40
0.00
0.00
0.00