Vous êtes sur la page 1sur 20

CURVES

BX-560G

Series HSC & HSC-S


3

Horizontal Split Case


Base Mounted Double Suction
50 Cycle

Performance Curves

Part of

Equipment Selection Programs

TABLE OF CONTENTS
USEFUL PUMP FORMULAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2900 RPM PUMP CURVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1450 RPM PUMP CURVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

USEFUL PUMP FORMULAS


Pressure
=
(PSI)

Head (Feet) x Specific Gravity


2.31

Head
=
(Feet)
Vacuum
=
(Inches of Mercury)

Pressure (PSI) x 2.31


Specific Gravity
Dynamic Suction Lift (Feet) x .883
x Specific Gravity

Horsepower
GPM x Head (Feet) x Specific Gravity
=
(Brake)
3960 x Pump Efficiency
Horsepower
GPM x Head (Feet) x Specific Gravity
=
(Water)
3960
Efficiency
=
(Pump)

Horsepower (Water)
x 100 Per Cent
Horsepower (Brake)

NPSH
= Atmospheric Pressure - Vapor Pressure + Total Suction Head
(Available)

Affinity Laws: Effect of change of speed or impeller diameter on centrifugal pumps.


GPM Capacity

Ft. Head

Impeller
Diameter
Change

Q2 =

D2
Q1
D1

H2 =

Speed
Change

Q2 =

RPM2
Q1
RPM1

H2 =

BHP

( DD ) H
2

P2 =

H
( RPM
RPM )
2

( DD ) P

P2 =

P
( RPM
RPM )
2

Where Q = GPM, H = Head, P = BHP, D = Impeller Dia., RPM = Pump Speed

BX-560G

2900 RPM PUMP CURVES

TOTAL
Bell AM-8077-4-50
& Gossett PUMP 2x3x11S HSC3 & HSC-S Series
HEAD CURVE
(Ft) (M)
32 38 43 47
100 279mm A
50 53
55
300
57
90 261mm B
250

80
70

200

2945

SPEED

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

MIN.
DIA.

279mm

MAX.
SPHERE

58

NO. OF
VANES

P-3265

6.35mm

INLET
AREA

140mm
49.7cm2

57

243mm C

55

226mm D

60
208mm E

150

50
190mm F
40

100

53

172mm G
30 154mm H

50

20 140mm I
50

38

47
43

10
2.1
8.0

2.4
7.7

3.3
6.8

5.2
4.9

7.9
2.2

NPSH REQD (METERS)


SUCTION LIFT (METERS)
A

kW

20

15

C
D

10
5

I H

Minimum recommended flow is 40% B.E.P.

0
0

10

0
TOTAL
HEAD

20

50
CURVE
Bell

30

100

AM-8079-4-50
& Gossett

PUMP

40
150

50

60

200

250

(M3/H)

70

2x3x11L HSC3 & HSC-S Series

2945

SPEED

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)
350

110

36

279mm A

43

49

54

58

61

63 64

250

63

9.65mm

MIN.
DIA.
INLET
AREA

140mm
61.9cm2

61

90
80

279mm

MAX.
SPHERE

64

NO. OF
VANES

P-3280

MAX.
DIA.

100 261mm B
300

FLOW

(GPM)

300

243mm C

70 226mm D
200
150
100

60 208mm E
50

190mm F
40 172mm G

58
54

30 154mm H
140mm I
20

49
43

50
10

2.1
7.9

kW

30

3.4 NPSH REQ D (METERS)


6.7 SUCTION LIFT (METERS)

6.2
3.9
C

20
10
0
0
0

A
B

I
10
50

20
100

30

40
150

Minimum recommended flow is 40% B.E.P.

50
200

60
250

70
300

80
350

90

(M3/H)
(GPM)

FLOW
3

2900 RPM PUMP CURVES

TOTAL
HEAD

Bell
CURVE

& Gossett
AM-8450-3-50

PUMP

4x6x10M HSC3 & HSC-S Series

SPEED

2960

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

300

125 304mm A
100 269mm B
75

200
100

62 68

NO. OF
VANES

P-3766-1
MIN.
DIA.

305mm

MAX.
SPHERE

(Ft) (M)
400

BX-560G

INLET
AREA

12.70mm

165mm
103cm2

73 76
78
78

76

233mm C

73

68

198mm D
50
165mm E
25

62

kW

2.8
7.3

4.2
5.9

5.4
4.7

NPSH REQD (METERS)


SUCTION LIFT (METERS)

100
A

75
B

50

25

Minimum recommended flow is 40% B.E.P.

0
0

50

0
TOTAL
HEAD

100

250
CURVE
Bell

150

500

AM-8453-4-50
& Gossett

200
750

PUMP

200
100

mA
125 302mm B
279mm C
100
256mm D
75 233mm E
210mm F
50 187mm G
165mm H
25

53

63

1250

(GPM)

1500

6x8x12M HSC3 & HSC-S Series

SPEED

70 75

79

2970

IMPELLER DATA

RPM

79

IMP.
NO.

MIN.
DIA.

325mm

MAX.
SPHERE

22.10mm

INLET
AREA

165mm
132cm2

70

4.7
5.4

6.6
3.5

NPSH REQD (METERS)


SUCTION LIFT (METERS)
A
B
C
D

100
50
H

MAX.
DIA.

NO. OF
VANES

P-3678-1

75

200

0
0

FLOW

82 83

150

(M3/H)

350

83 82

3.5
6.6
kW

300

NOTE: 4140 Shaft material is


Standard on this pump
at this speed.

150 325m

300

250
1000

(Ft) (M)

400

Minimum recommended flow is 50% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800

(M3/H)
(GPM)

FLOW

1450 RPM PUMP CURVES

TOTAL
HEAD

CURVE
Bell

AM-8078-5-50
& Gossett

PUMP

2x3x11S HSC3 & HSC-S Series

1450

SPEED

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

25 279mm A

33

39

43

47 49

51

53

20 243mm B
50

15

25

10 172mm D
5 139mm E

53

51

49

NO. OF
VANES

P-3265
MIN.
DIA.

279mm

MAX.
SPHERE

(Ft) (M)
75

BX-560G

140mm

INLET
AREA

6.35mm

49.7cm2

47 43

208mm C

kW

1.2
8.8

1.8
8.2

2.1
7.9

2.7
7.3

3.0 NPSH REQD (METERS)


7.0 SUCTION LIFT (METERS)

4
A

3
2

1
0
0

0
TOTAL
HEAD

25
CURVE
Bell

10

15
50

AM-8080-5-50
& Gossett

PUMP

Minimum recommended flow is 40% B.E.P.

20
75

25
100

30

35

125

150

2x3x11L HSC3 & HSC-S Series

SPEED

1455

40

45

175

(GPM)

IMP.
NO.
MAX.
DIA.

75

20
50

38

279mm A

45

50

55

58

25

60 61

62

62

MIN.
DIA.

279mm

INLET
AREA

9.65mm

61 60 58

243mm B

NO. OF
VANES

P-3280

MAX.
SPHERE

30

FLOW

IMPELLER DATA

RPM

(Ft) (M)

(M3/H)

140mm
61.9cm2

55

15 208mm C
10 172mm D

25

139mm E
5

0.7
9.4

1.2
8.9

2.1 NPSH REQD (METERS)


8.0 SUCTION LIFT (METERS)

kW

4
3

1
0
0
0

Minimum recommended flow is 40% B.E.P.

5
25

10

15
50

20
75

25
100

30
125

35
150

40
175

45
200

50

(M3/H)

225 (GPM)

FLOW
5

BX-560G

1450 RPM PUMP CURVES


PERFORMANCE CHARACTERISTIC CHART
80

4x6x10A
70

1450 R.P.M.
20

40

30

20

15

10

NPSH, FEET

TOTAL HEAD, METERS

TOTAL HEAD, FEET

50

NPSH, METERS

60

20
5

10

10

0
0

50

100

150

250

200

CAPACITY, CUBIC METERS/HR


200

600

400

800

1200

1000

CAPACITY, U.S. GALLONS PER MINUTE

TOTAL
HEAD

CURVE
Bell

AM-8451-3-50
& Gossett

PUMP

4x6x10M HSC3 & HSC-S Series

SPEED

1460

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)
100
75
50
25

30

304mm A

58

74 75

25 276mm B

76

20 248mm C
220mm D
15
193mm E
10 165mm F

76

75 74

71

68

64

MIN.
DIA.

305mm

MAX.
SPHERE

64 68
71

NO. OF
VANES

P-3766-1

12.70mm

INLET
AREA

165mm
103cm2

58

5
0

1.0
9.1

15

1.5
8.6

2.0
8.1

NPSH REQD (METERS)


SUCTION LIFT (METERS)

kW

12.5
10

A
B

7.5
C

D
E

2.5
0
0
6

F
Minimum recommended flow is 40% B.E.P.

20
100

40
200

60

80
300

100
400

120
500

140
600

160

(M3/H)

700

(GPM)

FLOW

BX-560G

1450 RPM PUMP CURVES


PERFORMANCE CHARACTERISTIC CHART
140

4x6x12A

40

130

1450 R.P.M.
120
35
110
100

70
60
50
40
30

NPSH, METERS

TOTAL HEAD, METERS

80

25

20

15

10

10

30
20

20

10

10
0

50

100

150

0
300

0
200

CAPACITY, CUBIC METERS/HR


0

100

200

400

300

600

500

700

800

900

1000

1100

CAPACITY, U.S. GALLONS PER MINUTE

TOTAL
HEAD

CURVE
Bell

AM-8699-2-50
& Gossett

PUMP

4x6x12XL HSC3 & HSC-S Series

SPEED

1470

150
125

45 350mm A
40

61 68 72 75

MAX.
DIA.

78 79
79

325mm B

75

30
25
20

50

NO. OF
VANES

P-4219
351mm

MAX.
SPHERE

35
100

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

9.39mm

MIN.
DIA.
INLET
AREA

198mm
183 cm2

78
75

299mm C

72
68

274mm D
248mm E

223mm F
15 198mm G

61

10
25
5
0

1.7
8.4

40
kW

TOTAL HEAD, FEET

90

NPSH, FEET

30

3.8
6.3

10.0 NPSH REQ D (METERS)


0.1 SUCTION LIFT (METERS)
A

30
B

20

10
0
0
0

GF
50
250

100
500

150

D
Minimum recommended flow is 40% B.E.P.

200
750

250
1000

(M3/H)
(GPM)

FLOW

1450 RPM PUMP CURVES

TOTAL
HEAD

CURVE
Bell

AM-8087-4-50
& Gossett

PUMP

4x6x14L HSC3 & HSC-S Series

1470

SPEED

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

MAX.
DIA.

45
125

BX-560G

40

52

350mm A

59

64

68

72

74

75

30

178mm

INLET
AREA

17.27mm

148cm2

77

325mm B

77
76

35
100

MIN.
DIA.

351mm

MAX.
SPHERE

76

NO. OF
VANES

P-3276-1

299mm C

74

25 274mm D
20 248mm E

50
25

15 223mm F
198mm G
10 177mm H
5

1.8
8.2

2.4
7.6

3.0
7.0

5.5 NPSH REQD (METERS)


4.6 SUCTION LIFT (METERS)
A

kW

20
B

15

10

5
H

0
0

20

40

100

200

60

80
300

Minimum recommended flow is 40% B.E.P.

100
400

120
500

140
600

160
700

180

200

(M3/H)

FLOW

(GPM)

800

PERFORMANCE CHARACTERISTIC CHART

4x6x14A

50

160

1450 R.P.M.
140

TOTAL HEAD, FEET

100

80

60

TOTAL HEAD, METERS

120

30

20

20

10

10

40

40

20

20

0
0

50

100

150

300

250

200

350

CAPACITY, CUBIC METERS/HR

0
8

NPSH, FEET

NPSH, METERS

40

200

400

600

800

1000

CAPACITY, U.S. GALLONS PER MINUTE

1200

1400

1600

BX-560G

1450 RPM PUMP CURVES


PERFORMANCE CHARACTERISTIC CHART
90

6x8x10A

25

80

1450 R.P.M.

20

50

40
30

TOTAL HEAD, METERS

TOTAL HEAD, FEET

60

15

10

10
30

20

20
5

5
10
0

NPSH, FEET

NPSH, METERS

70

10
0

0
0

100

500

200
300
400
CAPACITY, CUBIC METERS/HR

1000

1500

500

2000

2500

CAPACITY, U.S. GALLONS PER MINUTE

Bell & Gossett

BX-560G

1450 RPM PUMP CURVES


TOTAL
HEAD
(Ft) (M)

Bell
CURVE

& Gossett
AM-8454-4

35 325mm A
100
75
50
25

PUMP

6x8x12M HSC3 & HSC-S Series

1470

SPEED

IMPELLER DATA

RPM
IMP.
NO.

53 62

70 75

30 302mm B
279mm C
25
256mm D
20 233mm E

MAX.
DIA.

79 81

83
81

MIN.
DIA.

325mm

MAX.
SPHERE

83

NO. OF
VANES

P-3678-1

22.10mm

INLET
AREA

165mm
132cm2

79
75

15 210mm F
187mm G
10 165mm H

70

62

5
0

1.3
8.8

1.8
8.3

2.5
7.6

4.8
5.3

NPSH REQD (METERS)


SUCTION LIFT (METERS)

kW

30
A

25
B

20
C

15

10

Minimum recommended flow is 50% B.E.P.

0
0

50

0
TOTAL
HEAD

100

250
Bell
CURVE

150

500

& Gossett
AM-8025-6-50

200
750

250

300

1000

1250

6x8x12L HSC3 & HSC-S Series

PUMP

350

(M3/H)

400

SPEED

1480

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)
35
100

325mm A

58

72

77

30 297mm B

80

25 269mm C

325mm
25.40mm

INLET
AREA

178mm
251cm2

82
80

20 241mm D
50

MIN.
DIA.

82 83
83

75

NO. OF
VANES

P-2869-1

MAX.
SPHERE

66

FLOW

(GPM)

1500

77
72
66

15 213mm E

58

10 177mm F
25
5
0

2.3
7.8

3.0
7.1

3.5
6.6

4.7 NPSH REQD (METERS)


5.4 SUCTION LIFT (METERS)

kW

40
30

20

10

10

0
0

50

200

100
400

150
600

200
800

250
1000

Minimum recommended flow is 40% B.E.P.

300
1200

1400

350
1600

400
1800

450 (M3/H)
(GPM)

FLOW

BX-560G

1450 RPM PUMP CURVES

TOTAL
HEAD

Bell AM-8702-2-50
& Gossett PUMP
CURVE

6x8x12XL HSC3 & HSC-S Series

1480

SPEED

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

MAX.
DIA.

125

40
35

100
75

30
25
20

50

340mm A

63

70

79

82

MIN.
DIA.

340mm

MAX.
SPHERE

75

NO. OF
VANES

P-4220

203mm

INLET
AREA

25.40mm

262 cm2

84

318mm B

84
294mm C

82

79
75

272mm D
248mm E

70
63

225mm F

15 203mm G
10

25
5
0

NPSH REQD (METERS)


SUCTION LIFT (METERS)

3.0
7.1

4.0
6.1

6.0
4.1

9.0
1.1

kW

40

30

20
10

Minimum recommended flow is 40% B.E.P.

50

0
TOTAL
HEAD

0
0

250
CURVE
Bell

100

150

500

AM-7492-5-50
& Gossett

PUMP

200
750

250

300

1000

1250

6x8x13 HSC3 & HSC-S Series

350

400

1500

SPEED

1470

100
75
50

67

30 307mm B

2000

73

NO. OF
VANES

08-1668-1
MIN.
DIA.

333mm

MAX.
SPHERE

77

25 281mm C

(GPM)

2250

FLOW

IMPELLER DATA

MAX.
DIA.

59

550 (M3/H)

500

RPM
IMP.
NO.

332mm A

450

1750

(Ft) (M)
35

11.0
-

178mm

INLET
AREA

25.40mm

286cm2

81
77

20 256mm D

73

83

231mm E
15 205mm F
10 177mm G

67
59

25
5
0

2.3
7.8

30

3.5 NPSH REQD (METERS)


6.6 SUCTION LIFT (METERS)

kW

25

20

15

C
D

10

0
0
0

G
Minimum recommended flow is 40% B.E.P.

50
250

100
500

150

200
750

250
1000

300
1250

350
1500

400
1750

450
2000

500

(M3/H)

2250 (GPM)

FLOW
11

BX-560G

1450 RPM PUMP CURVES

TOTAL
Bell AM-8093-4-50
& Gossett PUMP 6x8x17M HSC3 & HSC-S Series
HEAD CURVE
(Ft) (M)
54
60 431mm A
62
68
72
55
406mm B
175
75
50
381mm C
150
45
355mm D
78
40
125
79
330mm E
35
304mm F
80
100
30
279mm G
25
75
254mm H
20
50

1480

SPEED

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

NO. OF
VANES

P-3248
MIN.
DIA.

432mm

MAX.
SPHERE

11.94mm

INLET
AREA

254mm
190cm2

75
72
68

62

15
54
10

25
0

kW

50

NPSH REQD (METERS)


SUCTION LIFT (METERS)

2.7
7.3

4.6
5.5

25

F E
H G

0
0

50

250

100
500

150

200
750

250
1000

300
1250

TOTAL
Bell AM-7497-5-50
& Gossett PUMP 6x8x17L HSC3 & HSC-S Series
HEAD CURVE
(Ft) (M)
431mm A
50 58 64
200
68 72
60
74
76 77
55 406mm B
175
78
50 381mm C
150
125

45

75

30
25
20

50

Minimum recommended flow is 40% B.E.P.

350

400

1500
SPEED

CB

450

(GPM)

1750

1480

(M3/H)

FLOW

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

NO. OF
VANES

08-1713-2
432mm

MAX.
SPHERE

12.70mm

MIN.
DIA.
INLET
AREA

254mm
250cm2

77
76

355mm D

74

40
35

100

330mm E

72

304mm F
279mm G
68

254mm H

64

15
10

25
0

kW

50

2.4
7.6

3.4
6.7

4.9
5.2

6.7
3.4

25
0
0
0
12

50
250

100
500

150

200
750

NPSH REQD (METERS)


SUCTION LIFT (METERS)
A
B
C
D
FE
G
H
250

1000

300
1250

350
1500

Minimum recommended flow is 40% B.E.P.

(M3/H)
(GPM)

FLOW

BX-560G

1450 RPM PUMP CURVES


TOTAL
SPEED 1480
Bell AM-7493-5-50
& Gossett PUMP 8x8x12 HSC3 & HSC-S Series
HEAD CURVE
(Ft) (M)
35 325mm A 49 59 66
72 77
81
100
30 304mm B
83
284mm C
25
83
75
264mm D
81
20 243mm E
77
72
50
15 223mm F
66
203mm G
59
10
25
5
0

2.1
8.0

40

3.0
7.1

4.3
5.8

6.1
4.0

MAX.
DIA.

325mm

MAX.
SPHERE

203mm
399cm2

C
E
F

10

G
Minimum recommended flow is 40% B.E.P.

5
0

100

200

500
CURVE
Bell

300

1000

AM-7498-5-50
& Gossett

PUMP

400

1500

500
2000

600
2500

8x8x17 HSC3 & HSC-S Series

(M3/H)

700
3000

1480

SPEED

FLOW

(GPM)

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

70 449mm A

50

59

65

70

60 421mm B

73

50 393mm C
365mm D
40 337mm E
309mm F
30
281mm G
20 254mm H

NO. OF
VANES

P-3984
MIN.
DIA.

450mm

MAX.
SPHERE

(Ft) (M)

100

28.70mm

INLET
AREA

15

150

MIN.
DIA.

25
20

200

NO. OF
VANES

P-3091

30
kW

IMP.
NO.

NPSH REQD (METERS)


SUCTION LIFT (METERS)

35

TOTAL
HEAD

IMPELLER DATA

RPM

24.89mm

INLET
AREA

254mm
259cm2

76
78

76
73

79
80

50
10
0

NPSH REQD (METERS)


SUCTION LIFT (METERS)

kW

100

3.7
6.4

4.2
5.9

5.9
4.2

75

A
B

50
25
0
0
0

H
50
250

100
500

150

200
750

250
1000

300
1250

350
1500

Minimum recommended flow is 40% B.E.P.

400
1750

450
2000

500
2250

550 (M3/H)
(GPM)

FLOW
13

1450 RPM PUMP CURVES

TOTAL
HEAD

CURVE
Bell

AM-7494-7-50
& Gossett

PUMP

8x10x12S HSC3 & HSC-S Series

SPEED

1480

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)

100
75
50

BX-560G

52 60 67
72 77
80 83

MIN.
DIA.

325mm

MAX.
SPHERE

35 325mm A
304mm B
30
284mm C
25 26
4mm D
20 243mm E
223m
15 203mm F
mG
10

NO. OF
VANES

08-1701-70

35.56mm

INLET
AREA

203mm
406cm2

85
85

83

80

77

25
5
0

2.3
7.8

4.7 7.0
5.4 3.1

NPSH REQD (METERS)


SUCTION LIFT (METERS)

kW

40

A
B

30
C

20
10

Minimum recommended flow is 40% B.E.P.

0
0

100

0
TOTAL
HEAD

500
CURVE
Bell

200

300

1000

AM-8273-4-50
& Gossett

PUMP

400

1500

600 (M3/H)

500
2000

2500

8x10x12L HSC3 & HSC-S Series

(GPM)

FLOW

1480

SPEED

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

MAX.
DIA.

125

40

325mm

35
100
75
50

30
25

42 52 60

304mm B

325mm

MAX.
SPHERE

67 72

77

81

NO. OF
VANES

P-3063

37.34mm

MIN.
DIA.
INLET
AREA

216mm
370cm2

84

284mm C

84

264mm D
20 243mm E

81

86

15 215mm F
10

25
5
0

2.1
8.0

2.3
7.8

3.5
6.6

4.7
5.4

7.0
3.1

NPSH REQD (METERS)


SUCTION LIFT (METERS)
A

kW

50
B

40
C

30
D
E

20
10
0
0
14

F
100
500

200
1000

300
1500

400

500
2000

600
2500

Minimum recommended flow is 40% B.E.P.

700
3000

(M3/H)
(GPM)

FLOW

1450 RPM PUMP CURVES

TOTAL
HEAD

Bell
CURVE

& Gossett
AM-7499-7-50

8x10x17S HSC3 & HSC-S Series

PUMP

1485

SPEED

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

150
100

56

64

70

60 419mm B

78

24.64mm

INLET
AREA

254mm
371cm2

81

50 388mm C
358mm D
40
327mm E
30 297mm F
20

MIN.
DIA.

450mm

MAX.
SPHERE

75

NO. OF
VANES

08-1626-2

MAX.
DIA.

70 449mm A
200

BX-560G

81
78

83

75

254mm G

70

64

50
10
0

56

0
1.8
8.2

2.4
7.6

3.4
6.7

4.3 NPSH REQD (METERS)


5.8 SUCTION LIFT (METERS)

kW

125
A

100
75

50
25

Minimum recommended flow is 40% B.E.P.

0
0

100

0
TOTAL
HEAD

200

500
Bell
CURVE

300

1000

& Gossett
AM-8272-4-50

400

1500

500
2000

600
2500

8x10x17L HSC3 & HSC-S Series

PUMP

700

800

3000
SPEED

3500

1485

(GPM)

(Ft) (M)

200
150
100

439mm

MAX.
SPHERE

56

64

71

76 79

82

NO. OF
VANES

P-2965-3

MAX.
DIA.

46

FLOW

IMPELLER DATA

RPM
IMP.
NO.

439mm A
419mm B
60 398mm
C
375mm
D
50
353mm E
40 330mm F
304mm G
30

(M3/H)

900

29.46mm

MIN.
DIA.
INLET
AREA

305mm
422cm2

84 85
85 84

20
50
10
0

2.8
7.3

3.5
6.6

4.5 NPSH REQD (METERS)


5.6 SUCTION LIFT (METERS)
A

125
B

kW

100

75

50

25
0
0
0

Minimum recommended flow is 40% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800

(M3/H)

3500

(GPM)

FLOW
15

BX-560G

1450 RPM PUMP CURVES

TOTAL
HEAD

Bell
CURVE

& Gossett
AM-8630-2-50

8x10x20S HSC3 & HSC-S Series

PUMP

SPEED

1485

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)

250
200
150
100

90 513mm A
48
80 7mm B
462mm
C
70
436mm D
60 411mm E
386mm F
50
360mm G
40 335mm H
304mm I
30

51

60 66

71

75

78

MIN.
DIA.

513mm

MAX.
SPHERE

300

NO. OF
VANES

P-3819
INLET
AREA

13.46mm

305mm
441cm2

79
79

78

80

75
71

66

20
50
10
1.5
8.6

kW

200

2.1
8.0

3.0
7.1

4.6 NPSH REQD (METERS)


5.5 SUCTION LIFT (METERS)

150
100
F E
H G

50
I

Minimum recommended flow is 40% B.E.P.

0
0

100

0
TOTAL
HEAD

B
DC

500
CURVE
Bell

200

300

1000

AM-8619-3-50
& Gossett

PUMP

400

1500

500
2000

600

700

2500

8x10x20L HSC3 & HSC-S Series

800

(GPM)

3000
SPEED

1485

MAX.
DIA.

(Ft) (M)

250
200
150
100

58

65

71

76

79

82 83

84

NO. OF
VANES

P-3820
513mm

MAX.
SPHERE

513mm
A
85 487m
mB
75 462mm C
436mm D
65
411mm E
55 386mm F
360mm G
45 335m
mH
35 305mm I

FLOW

IMPELLER DATA

RPM
IMP.
NO.

300

(M3/H)

18.00mm

MIN.
DIA.
INLET
AREA

305mm
477cm2

84
83

82
79

76
71
65

25
50

15
1.2
8.8

200
kW

2.1
7.9

4.9 NPSH REQD (METERS)


5.2 SUCTION LIFT (METERS)
A
B
C
D
F E
H G
I

150
100
50
0
0
0

16

Minimum recommended flow is 40% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800
3500

900

(M3/H)

4000

(GPM)

FLOW

1450 RPM PUMP CURVES

TOTAL
HEAD

Bell
CURVE

& Gossett
AM-7495-5-50

PUMP

10x10x12 HSC3 & HSC-S Series

SPEED

1480

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)
325mm
A
307mm
B
30 28
9mm
C
25 271mm D
254mm
E
20 236mm
F
15

75
50

45 52

58 64
68 72

76

79

81

NO. OF
VANES

08-1629-48
MIN.
DIA.

325mm

MAX.
SPHERE

35
100

BX-560G

236mm

INLET
2
AREA 557cm

39.12mm

81
79

10
25
5
0

2.6
7.5

4.7
5.4

NPSH REQD (METERS)


SUCTION LIFT (METERS)
A

50

kW

40
30

20
F

10

Minimum recommended flow is 40% B.E.P.

0
0

100

0
TOTAL
HEAD

500
CURVE
Bell

200

300

1000

AM-7496-6-50
& Gossett

PUMP

400

1500

500
2000

600
2500

10x12x12M HSC3 & HSC-S Series

(M3/H)

700

(GPM)

3000
SPEED

1480

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)
125
100

FLOW

75

279m
25 264mm D
mE
20 248mm F

50

220mm G

15

48

57

65

71

76

80

MIN.
DIA.

325mm

MAX.
SPHERE

325mm A
35 309mm B
30 294mm C

NO. OF
VANES

WT-20646-3
INLET
AREA

28.45mm

221mm
498cm2

83
83

80

85

76

10
25
5
0

0
NPSH REQD (METERS)
SUCTION LIFT (METERS)

kW

100

4.6
5.5

5.8
4.3

7.3
2.8

9.1
1.0
A

75
B

50

25
0
0
0

Minimum recommended flow is 40% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800
3500

900
4000

1000
4500

1100 (M3/H)
(GPM)

FLOW
17

BX-560G

1450 RPM PUMP CURVES


TOTAL
HEAD

CURVE
Bell

AM-8705-2-50
& Gossett

PUMP

10x12x12XL HSC3 & HSC-S Series

SPEED

1480

IMPELLER DATA

RPM
IMP.
NO.
MAX.
DIA.

(Ft) (M)
125

40

52 60
67 73
78

325mm B

75
50

218mm

INLET
AREA

40.64mm

563cm2

82 85
87

35
100

MIN.
DIA.

343mm

MAX.
SPHERE

342mm A

NO. OF
VANES

P-4221

307mm C
30 289mm D
25 271mm E
254mm F
20 236mm G
H
15 218mm

87

85

82

78

73

10
25
0

kW

150

2.6
7.4

3.9
6.2

5.2
4.8

7.3 8.3
2.8 1.8

9.4 NPSH REQD (METERS)


0.6 SUCTION LIFT (METERS)

100
50
0
0
0
TOTAL
HEAD

F E
HG
200
1000

400

600

2000

Bell AM-8069-5-50
& Gossett PUMP
CURVE

800

3000

1000
4000

Minimum recommended flow is 40% B.E.P.

1200
5000

10x12x14 HSC3 & HSC-S Series

1400
6000

SPEED

1480

(M3/H)
(GPM)

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

MAX.
DIA.

50 355mm A
150
125
100
75

47

57

65

71

76

80

45 337mm B

FLOW

MIN.
DIA.

356mm

MAX.
SPHERE

83

INLET
AREA

41.15mm

254mm
604cm2

86

40

86

320mm C
35 302mm D

83

80

30 284mm E
269mm F
25 254mm G

76

71

20
50

NO. OF
VANES

P-3212-2

15
10

25
5

NPSH REQD (METERS)


SUCTION LIFT (METERS)

2.8
7.3

4.2
5.9

5.6
4.5

kW

125

100

B
C

75

50
25
0
0
18

G F

Minimum recommended flow is 40% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800
3500

900
4000

1000
4500

1100 (M3/H)
(GPM)

FLOW

1450 RPM PUMP CURVES

TOTAL
HEAD

CURVE
Bell

AM-7854-6-50
& Gossett

PUMP

10x12x17 HSC3 & HSC-S Series

SPEED

1485

IMPELLER DATA

RPM
IMP.
NO.

(Ft) (M)

MAX.
DIA.

70 444mm A
200
150
100
50

54

60 419mm B
393mm C
50
368mm D
40 342mm E
317mm F
30
292mm G
20 254mm H

62

68

74

78

82

NO. OF
VANES

08-1361
MIN.
DIA.

445mm

MAX.
SPHERE

82

78

74

68

kW

62

54
3.6
6.5

4.7
5.4

5.5 NPSH REQD (METERS)


4.6 SUCTION LIFT (METERS)

100
75
50

G
25

557cm2

84

85

0
0

254mm

INLET
AREA

34.54mm

84

10
0

BX-560G

H
Minimum recommended flow is 40% B.E.P.

100
500

200
1000

300
1500

400

500
2000

600
2500

700
3000

800
3500

900
4000

1000

(M3/H)

4500 (GPM)

FLOW

19

Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
Were 12,700 people unified in a common purpose: creating innovative solutions
to meet our worlds water needs. Developing new technologies that will improve
the way water is used, conserved, and re-used in the future is central to our work.
We move, treat, analyze, and return water to the environment, and we help people
use water efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with customers who
know us for our powerful combination of leading product brands and applications
expertise, backed by a legacy of innovation.
For more information on how Xylem can help you, go to www.xyleminc.com

Xylem Inc.

8200 N. Austin Avenue


Morton Grove, Illinois 60053
Phone: (847) 966-3700
Fax: (847) 965-8379
www.bellgossett.com
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.
2013 Xylem Inc. BX-560G January 2003

Vous aimerez peut-être aussi