Vous êtes sur la page 1sur 2

DATOS

b=
lm=
hm=
F'c=
Fy=

30
400
2700
210
4200

cm
cm
cm
kg/cm2
kg/cm2

1. DISEO PRELIMINAR POR FLEXION


1.1Acero en la Cabeza
d= 320
cm
Ku= 28.976497
-Cuantia=>
0.0085
As= 81.6
cm2
Area de Varilla=>
5.1
=1"
Var = 16
-Var =>
18
Var de ( )"
2 DISEO POR CORTANTE
2.1 Cortante Nominal
Vn= 452130.95 kg
Vn= 452.13095 TN
112.5
<
452.13095
2.2Cortante Concreto
alfaC=
6.75
-AlfC=>
0.53
Vc= 92165.156 Kg.
Vc= 92.165156 TN
2.3Restriccion para Vc
Nu=
-69.505
0.8345119
>0
2.4 Nuevo Vc
Vc=

Cm=
Cv=
Cs=
Mu=
Vu=

CARGAS
121.5
108
356.38
890.158
112.5

2.7 Cuantia Real


Var Xmetro=
15.33
-VarM=>
15
(Redondeado a menos)
PhR=

Ah=
7.5
-Diametro=>
0.71
Sv= 0.0946667
-Sv=>
0.075
-Capa=>
2
Sv=

P=
585.88 tn
M=
890.158 tn.m
I= 160000000 cm4

ok

> 0.0025

cm2
=3/8"
m
m
m

0.15

cm2
=3/8"

2.9 Longitud De Confinamiento


-Drif=>
0.0056
C > 119.04762

2.5 Cortante de Acero


Vs= 55.440021 TN

Ah=
7.5
-area de varilla=>0.71
Sh= 0.0946667
Sh=>
0.075
-Capa=>
2
Sh=
0.15

0.00355

2.8 Cuantia Vertical


Pv = 0.0002688 > 0.0025
-PV=>
0.0025

76.91292 TN

2.6 Cuantia Horizontal


Ph=
0.0011
-Ph=>
0.0025

Tn
Tn
Tn
tn.m
tn

C=
C=

8775.6705
87.756705 cm

87.756705

>
119.04762
(NO SE CONFINA)
3 DISEO POR CAPACIDAD
-Mn=>
2396.12 TN.m
Vn=

302.82658

Vs=

225.91366

3.1 Cuantia Horizontal


Ph= 0.0044824 > 0.0025
-Ph=> 0.00448
Ah=
13.44
-Diametro=>
1.29
Sh= 0.0959821
-Sh=>
0.075
-Cap=>
2
Sh=
0.15

cm2
1/2"
m
m

3.2 Cuantia Real


Var Xmetro=
15.33
-VarM=>
15
(Redondeado)
PhR=

0.00645

3.3 Cuantia Vertical


Pv = -0.0058938 > 0.0025
-PV=>
0.0025
Av=
7.5
-Diametro=>
0.71
Sv= 0.0946667
-Sv=>
0.075
-Cap=>
2
Sv=
0.15

cm2
=3/8"
m
m

4. VERIFICACIONES
-Lalm=>
-S=>
AsALMA=>
As Di=
0.0178442
-Pu =>
Mcr=
Mcr=
2396.12
N u=
Av=
Vu=
121.5

320

cm
15 cm
42.666667
43
0.71
= 3/8"
< 0.01
247.03 TN
90374563
90374.563 Tn.m
>

90374.563

109.35
214.13
514434.96
<

514.43496