FLUKE Model 5500A
Reference Standard
DCV Accuracy 50 PPM
MULIT PRODUCT
Calibration Laboratory owned
DCI Accuracy 0.01 %setting
CALIBRATOR
Resistance Accuracy 0.0009% Setting
ACV Accuracy 0.03% setting
ACI Accuracy 0.06% setting
Capacitance Accuracy 0.25% setting
Thermocouple Accuracy 0.14% setting
RTD Accuracy 0.03% setting
DC Power Accuracy 0.08% setting
Ac Power Accuracy 0.15% setting
Phase Accuracy 0.15% setting
Frequency Accuracy 25 PPM
.
Working Standard
Calibration Laboratory owned
THERMOCOUPLE CALIBRATOR / SIMULATOR / DATA LOGGER, MULTIFUNCTION CALIBRATOR

Temperature Laboratory Traceability Chart


National Metrology
Institute
NIMT

NIMT

NIMT

.
Reference Standards
Calibration Laboratory owned

STANDARD
PLATINUM
RESISTANCE TESTER

Standard Platinum Resistance Tester


Beuing Const Co., Ltd. Model CST 6601
Accuracy 0.01C

.
Industrial Platinum Resistance Tester
ASL Model T100-250 Accuracy 0.5C
INDUSTRIAL
INDUSTRIAL
DIGITAL
Working Standard
Industrial Platinum Resistance Tester
PLATINUM
PLATINUM
PRECISION
Calibration Laboratory owne
ASL Model T100-450 Accuracy 0.5C
RESISTANCE TESTER
RESISTANCE TESTER
THERMOMETER
Digital Precision thermometer
ASL Model F250 Accuracy 10 mK

Dimension Instrument

CALIBRATION BATH [ DRY BLOCK ], THERMOMETER CALIBRATOR CALIBRATION SYSTEM [ LIQUID BATH ]

Temperature Laboratory Traceability Chart


National Metrology
Institute
NIMT

NIMT

FLUKE Model 5500A, DCV Accuracy 50 PPM


Reference Standard
DCI Accuracy 0.01 %setting, Resistance Accuracy 0.0009% setting
MULIT PRODUCT
Calibration Laboratory owned
ACI Accuracy 0.06% setting, ACV Accuracy 0.03% setting
CALIBRATOR
Capacitance Accuracy 0.25% setting, Thermocouple Accuracy 0.14% setting
RTD Accuracy 0.03% setting, DC Power Accuracy 0.08% setting
Ac Power Accuracy 0.15% setting, Phase Accuracy 0.15% setting
Frequency Accuracy 25 PPM
..
Working Standard
Document Process Calibrator
DOCUMENT
PROCESS
DOCUMENT
PROCESS
Calibration Laboratory owned
FLUKE Model 702 Accuracy 0.1% FS
CALIBRATOR
CALIBRATOR
Document Process Calibrator
FLUKE Model 741B Accuracy 0.1% FS

Temperature Instrument
TEMPERATURE CONTROLLER, UNIVERSAL INPUT PANEL METER, PANEL MOUTH THERMOMETER
TEMPERATURE PROCESS CONTROLLER MEASURE, UNIVERSAL CONTROLLER MEASURE

Temperature Laboratory Traceability Chart


National Metrology
Instrument

NIMT

NIMT

NIMT

NIMT

Reference Stand
Calibration Laboratory

Standard Platinum Resistance Tester


Beuing Const,.Ltd. Model CST 6601 Accuracy 0.01C

STANDARD
PLATINUM
RESISTANCE TESTER

..
Working Stand
INDUSTRIAL PLATINUM RESISTANCE TESTER
Calibration Laboratory
ASL MODEL T100-250 ACCURACY 0.05 C
INDUSTRIAL
PLATINUM
RESISTANCE TESTER

TEMPERATURE BATH
RTS 35S

TEMPERATURE BATH
HTS 300A

INDUSTRIAL
PLATINUM
RESISTANCE TESTER

METAL BLOCK
B140

DIGITAL PRECISION
THERMOMETER

METAL BLOCK
B700

INDUSTRIAL PLATINUM RESISTANCE TESTER


ASL MODEL T100-450 ACCURACY 0.05 C
TEMPERATURE BATH
JINGMI MODEL RTS-35S ACCURACY 0.01 C
JINGMI MODEL HTS-300A ACCURACY 0.01 C
METAL BLOCK
ASL MODEL B140 ACCURACY 0.4 C
ASL MODEL B700 ACCURACY 0.4 C

.
Temperature Instrument

TEMPERATURE ALARMS, DIAL / POCKET THERMOMETER, SURFACE THERMOMETER, HOT AND COLD HOLDING THERMOMETER
BIMETAL THERMOMETER, DIGITAL THERMOMETER WITH TC PROBE, THERMOMETER WITH PROBE WITH ALARM,
LIQUID IN GLASS THERMOMETER, DIGITAL THERMOMETER WITH RTD PROBE, TC GENERAL-PURPOSE PROBE, TC PENETRATION PROBE
TC AIR/GAS PROBE, TC SURFACE PROBE, TC CLAMP PROBE, TC WIRE PROBE, TC THERMOWELLS PROBE

Temperature Laboratory Traceability Chart


National Metrology
Institute
NIMT

NIMT

Working normal
Calibration Laboratory owned

TEMPERATURE
MULIT PRODUCT&
HUMIDITY
METER
CALIBRATOR

INFRARED
CALIBRATOR

TEMPERATURE & HUMIDITY METER


VAISALA MODEL HMI33 ACCURACY 0.1% RDG.
INFRARED CALIBRATOR
HART MODEL 9132 ACCURACY 0.8 C

.
Temperature/Humidity
Instrument
DIGITAL THERMOHYGRO-METER, ANALOG THERMOHYGRO-METER, HYGROMETER, INFRARED
THERMOMETER,

Temperature Laboratory Traceability Chart


National Metrology
Institute
NIMT

NIMT

Working Standard
Calibration Laboratory

DOCUMENT
PROCESS
CALIBRATOR

DOCUMENT
PROCESS
CALIBRATOR

DOCUMENT PROCESS CALIBRATOR


FLUKE MODEL 702 ACCURACY 0.1% F.S.
FLUKE MODEL 741B ACCURACY 0.1% F.S.

Temperature Instrument

INFRARED SENSOR TYPE K,J VOLTAGE, INFRARED SENSOR WITH TRANSMITTER TYPE K,J VOLTAGE, CURRENT
INFRARED PROCESS THERMOMETER SYSTEMS TYPE K,J,T,E,N,R,S,mA[close loop], TEMPERATURE RECORD WITH PROBE
DATA LOGGER, TEMPERATURE VOLTAGE / DATA LOGGER TYPE J,K,T,E,VOLTAGE, DIGITAL THERMOMETER [ SIMMULATION ]

Temperature Laboratory Traceability Chart


National Metrology
Institute

NIMT

NIMT

Working Standard
Calibration Laboratory

HYDRA DATA
LOGGER

DOCUMENT
PROCESS
CALIBRATOR

Hydra Data Logger


FLUKE Model 2635A Accuracy 0.1%
DOCUMENT PROCESS CALIBRATOR
FLUKE MODEL 744 ACCURACY 0.1% F.S.

Temperature Instrument
MUFFLE FURNANCES, TUBE FURNANCES, CRUCIBLE FURNANCES, MELTNG FURNANCES, MANIFOLDS FREEZER, BENCHTOP SHELL FREEZER
DRYING FREEZER, DIGITAL INCUBATOR, ANALOG INCUBATOR, AUTOCLAVE, GRAVITY CONVECTION OVEN, MECHANICAL CONVECTION
OVEN,CLEANROOM OVEN, SAFETY OVEN, VACUUM OVEN