Vous êtes sur la page 1sur 27

APPLICATION FOR LOW VOLTAGE DIRECTIVE

On Behalf of
Sheenly Lighting Co., Ltd
LED Panel
Model No.: See report the second page for details

Prepared For :

Sheenly Lighting Co., Ltd


No.88 Zhuyuan Road, Minhang District, Shanghai, China

Prepared By :

Accurate Technology Co., Ltd.


F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd.
Science & Industry Park, Nanshan District, Shenzhen 518057
P. R. China

Date of Test:
Date of Report:
Report Number:

October 09-26, 2011


October 31, 201
ATS2011727

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

TEST REPORT
IEC 60598-2-2 and/or EN 60598-2-2
Part 2: Particular requirements
Section Two Recessed luminaires
Report Reference No......................:

ATS2011727

Tested by (name+signature) ............:

Toby

Approved by (name+signature)........:

Jenny

Date of issue.....................................:

October 31, 2011

Testing Laboratory .........................:

Accurate Technology Co., Ltd.

Address ............................................:

F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd.


Science & Industry Park, Nanshan District, Shenzhen 518057
P. R. China

Testing procedure ............................:

CBTL

Testing location/ address .................:

(Same as above)

Applicants name............................:

Sheenly Lighting Co., Ltd

Address ............................................:

No.88 Zhuyuan Road, Minhang District, Shanghai, China

RMT

SMT

WMT

TMP

Test specification:
Standard ...........................................:

IEC 60598-2-2:1996+A1:1997 (Ed. 2.1:1997)


used in conjunction with IEC 60598-1:2008
EN 60598-2-2:1996+A1:1997 used in conjunction with
EN 60598-1:2008+A11:2009

Test procedure .................................:

CE

Non-standard test method..:

N/A

Test Report Form No......................:

IECEN60598_2_2B

TRF Originator..................................:

Intertek Semko AB

Master TRF.......................................:

Dated 2005-03

Copyright 2005 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE
is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test item description .....................: LED Panel
Manufacturer ....................................:

Sheenly Lighting Co., Ltd

Address ............................................:

No.88 Zhuyuan Road, Minhang District, Shanghai, China

Model and/or Type reference ...........:

See page 2

Ratings (V; Hz) ................................:

AC100-240V, 50/60Hz, Max.50W


For different models, power difference see General product
marking on page 2
Similar construction and schematic with different shape and lamp
ratings

Power rating (W) ..............................:


Model difference ...............................:

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 2 of 26

Report No.: ATS2011727

Test item particulars ..................................................: LED panel with independent power unit
Possible test case verdicts:
- test case does not apply to the test object ................ : N (not applicable)
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing
Date of receipt of test item............................................ : October 09, 2011
Date (s) of performance of tests................................... : October 09-26, 2011
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
List of test equipment must be kept on file and available for review.
Throughout this report a comma (point) is used as the decimal separator.
In this report requirements valid for EN only are marked with (EN).
General product information:
See below model list for details, Model SL-PAN-50W-NW-AN is selected to represent the whole series
because of maximum wattage for this model.
Models

Rated wattage

Rated Input

SL-PAN-50W-WW/NW/PW-AN/LS

50W

SL-PAN-06W-WW/NW/PW-SN

6W

SL-PAN-12W-WW/NW/PW-SN/AN

12W

SL-PAN-20W-WW/NW/PW-AN

20W

SL-PAN-26W-WW/NW/PW-BN/AN/LS

26W

AC 100-240V,

SL-PAN-40W-WW/NW/PW-BN

40W

50/60Hz

SL-PAN-45W-WW/NW/PW-AN/BN

45W

SL-PAN-25W-TC-LS

25W

SL-PAN-50W-WT-LS

50W

SL-PAN-50W-BW-AN/LS

50W

Copy of marking plate:


Marking on main body.
For model SL-PAN-50W-WW/NW/PW-AN/LS :
LED panel
Model: SL-PAN-50W-WW/NW/PW-AN/LS
Rating: 100-240V~ 50/60Hz 50W

Sheenly Lighting Co., Ltd


NOTE: This label for reference only, final label on product shall include information
showed on the exampled label at least.

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 3 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.1 (0)

GENERAL TEST REQUIREMENTS

1.2 (0.1)

Information for luminaire design considered

Result - Remark

Verdict
P

Standard
Yes

No

1.2 (0.3)

More sections applicable ....................................... : Yes

No

1.4 (2)

CLASSIFICATION

1.4 (2.2)

Type of protection .................................................. :

Class I

1.4 (2.3)

Degree of protection .............................................. :

IP20

1.4 (2.4)

Luminaire only suitable for non-combustible


Yes
surfaces ................................................................ :

No

Luminaire suitable for normally flammable surfaces Yes

No

Luminaire suitable to be covered by insulating


Yes
material.. :

No

Luminaire for normal use ...................................... :

Yes

No

Luminaire for rough service .................................. :

Yes

No

1.4 (2.5)

1.5 (3)

MARKING

2.5.1 (-)

Warning notice, if not suitable for insulating ceiling

P
Warning In manufacturers
instruction:

Under no circumstances, be
covered with insulating
matting or similar materials
1.5 (3.2)

Mandatory markings

(see page 2)

Position of the marking

On the outside of main body

Format of symbols/text

Symbols: 5.0mm min

Letter: 2.0mm min


1.5 (3.3)

Additional information
Language of instructions

P
In English and / or local
language

1.5 (3.3.1)

Combination luminaires

1.5 (3.3.2)

Nominal frequency in Hz

1.5 (3.3.3)

Operating temperature

1.5 (3.3.4)

Symbol or warning notice

1.5 (3.3.5)

Wiring diagram

1.5 (3.3.6)

Special conditions

1.5 (3.3.7)

Metal halide lamp luminaire warning

1.5 (3.3.8)

Limitation for semi-luminaires

1.5 (3.3.9)

Power factor and supply current

1.5
(3.3.10)

Suitability for use indoors

50/60 Hz

P
N

Warning notice: the luminaire


can under no circumstances
be mounted on normally
flammable surfaces

Not metal halide lamp


luminaire

Indoor use only

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 4 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

1.5
(3.3.11)

Luminaires with remote control

No remote control

1.5
(3.3.12)

Clip-mounted luminaire warning

No clip-mounted luminaire

1.5
(3.3.13)

Specifications of protective shields

1.5
(3.3.14)

Symbol for nature of supply

1.5
(3.3.15)

Rated current of socket outlet

No socket outlet

1.5
(3.3.16)

Rough service luminaire

Luminaire for normal use

1.5
(3.3.17)

Mounting instruction for type Y, type Z and some


type X attachments

1.5
(3.3.18)
1.5
(3.3.19)
1.5
(3.3.20)
1.5
(3.3.101)

Non-ordinary luminaires with PVC cable

1.5 (3.4)

Test with water

15s with water

Test with hexane

15s with hexane

Legible after test

Yes

Label attached

Label was not be easily


removable and show no
curling

N
Ordinary luminaire

Protective conductor current in instruction if


applicable
Provided with information if not intended to be
mounted within arms reach
Adequate warning on the package (EN)

N
N
N
P

1.6 (4)

CONSTRUCTION

1.6 (4.2)

Components replaceable without difficulty

1.6 (4.3)

Wire ways smooth and free from sharp edges

1.6 (4.4)

Lampholders

1.6 (4.4.1)

Integral lampholder

1.6 (4.4.2)

Wiring connection

1.6 (4.4.3)

Lampholder for end-to-end mounting

1.6 (4.4.4)

Positioning

- pressure test (N) .................................................. :

- bending test (Nm) ................................................. :

1.6 (4.4.5)

Peak pulse voltage

1.6 (4.4.6)

Centre contact

1.6 (4.4.7)

Parts in rough service luminaires resistance to


tracking

1.6 (4.4.8)

Lamp connectors

1.6 (4.4.9)

Caps and bases correctly used

No such parts

LED lamp, no lampholder


used

Not rough service luminaires

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 5 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.6 (4.5)

Starter holders
Starter holder in luminaires other than class II

Result - Remark

Verdict
N

No starter holder

Starter holder class II construction

Terminal blocks

Tails

Unsecured blocks

1.6 (4.7)

Terminals and supply connections

1.6 (4.7.1)

Contact to metal parts

1.6 (4.7.2)

Test 8 mm live conductor

Test 8 mm earth conductor

1.6 (4.7.3)

Terminals for supply conductors

1.6
(4.7.3.1)

Welded connections:

- stranded or solid conductor

- spot welding

- welding between wires

- Type Z attachment

- mechanical test according to 15.8.2

- electrical test according to 15.9

- ageing test according to 15.9.2.3 and 15.9.2.4

1.6 (4.7.4)

Terminals other than supply connection

1.6 (4.7.5)

Heat-resistant wiring/sleeves

1.6 (4.7.6)

Multi-pole plug

1.6 (4.6)

1.6 (4.8)

No multi-pole plug

- test at 30 N

Switches:

- adequate rating

No switch

- adequate fixing

- polarized supply

- compliance with 61058-1 for electronic switches

1.6 (4.9)

Insulating lining and sleeves

1.6 (4.9.1)

Retainment

Method of fixing...................................................... :

Insulated linings and sleeves

a) & c) Insulation resistance and electric strength

1.6 (4.9.2)

b) Ageing test. Temperature (C) ......................... :


1.6 (4.10)

See ANNEX 2

Insulation of Class II luminaries

N
N

(Component only, required as Class II luminaries)


1.6
(4.10.1)

No contact, mounting surface - accessible metal


parts - wiring of basic insulation

Class I luminaries

Safe installation fixed luminaires

Capacitors and switches

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 6 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

Interference suppression capacitors according to


IEC 60384-14

Assembly gaps:

- not coincidental

- no straight access with test probe

Retainment of insulation:

- fixed

- unable to be replaced; luminaire inoperative

- sleeves retained in position

- lining in lampholder

1.6 (4.11)

Electrical connections

1.6
(4.11.1)

Contact pressure

1.6
(4.11.2)

Screws:

1.6
(4.10.2)

1.6
(4.10.3)

1.6
(4.11.3)

- self-tapping screws

Self-tapping screws not used

- thread-cutting screws

Thread-cutting screws not


used

- at least two self-tapping screws

Screw locking:

- spring washer

- rivets

1.6
(4.11.4)

Material of current-carrying parts

>50% copper

1.6
(4.11.5)

No contact to wood

No wood materials

1.6
(4.11.6)

Electro-mechanical contact systems

1.6 (4.12)

Mechanical connections and glands

1.6
(4.12.1)

Screws not made of soft metal

Screws of insulating material

Torque test: torque (Nm); part ............................... :

Screw for fixing enclosure


3.7mm1.2Nm

Torque test: torque (Nm); part ............................... :

Screw for fixing Earthing,


3.5mm0.8Nm

1.6
(4.12.2)

Screws with diameter < 3 mm screwed into metal

1.6
(4.12.4)

Locked connections:

- fixed arms; torque (Nm)....................................... :

- lampholder; torque (Nm)....................................... :

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 7 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

- push-button switches; torque 0,8 Nm................... :

1.6
(4.12.5)

Screwed glands; force (N) ...................................... :

1.6 (4.13)

Mechanical strength

1.6
(4.13.1)

Impact tests:

1.6.1 (-)

- recessed parts providing protection against


electric shock; energy (Nm) ................................ :

- other recessed parts; energy (Nm)................... :

- other recessed parts; energy (Nm)................... :

- fragile parts; energy (Nm)..................................... : Cover, 0.2Nm

- other parts; energy (Nm) ...................................... : 0.35Nm test carried on other


parts

1) live parts

Not become accessible

2) linings

Not become accessible

3) protection

Remain accordance against


ingress of dust, sold objects
and moisture classification

1.6
(4.13.1)

4) covers

1.6
(4.13.3)

Straight test finger

1.6
(4.13.4)

Rough service luminaires

- IP54 or higher

Not rough service luminaires

a) fixed

b) hand-held

c) delivered with a stand

d) for temporary installations and suitable for


mounting on a stand

1.6
(4.13.6)

Tumbling barrel

Not socket-outlet-mounted
luminaires

1.6 (4.14)

Suspensions and adjusting devices

1.6
(4.14.1)

Mechanical load:

A) four times the weight

4.5kg x 4=18kg, 1h, test and


passed

B) torque 2,5 Nm ................................................... :

2.5Nm, 1min, no damage

C) bracket arm; bending moment (Nm) ................. :

D) load track-mounted luminaires

E) clip-mounted luminaires, glass-shelve.


Thickness (mm) .................................................... :

metal rod. Diameter (mm) ..................................... :

Fixed luminaire or independent control gear without


fixing devices

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 8 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.6
(4.14.2)

Load to flexible cables

Mass (kg) ............................................................... :

Stress in conductors (N/mm) ................................ :

Semi-luminaires mass (kg) ................................ :

Semi-luminaires bending moment (Nm) ............. :

Adjusting devices:

- flexing test; number of cycles .............................. :

- strands broken

- electric strength test afterwards

1.6
(4.14.3)

Result - Remark

Verdict

1.6
(4.14.4)

Telescopic tubes: cords not fixed to tube; no strain


on conductors

Telescopic tubes not used

1.6
(4.14.5)

Guide pulleys

No guide pulleys

1.6
(4.14.6)

Strain on socket-outlets

Not direct plug-in type

1.6 (4.15)

Flammable materials:

- glow-wire test 650

- spacing 30 mm

- screen withstanding test of 13.3.1

- screen dimensions

- no fiercely burning material

- thermal protection

- electronic circuits exempted

Luminaires made of thermoplastic material with lamp control gear

a) construction

b) temperature sensing control

1.6
(4.15.2)

c) surface temperature
1.6 (4.16)
1.6
(4.16.1)

1.6
(4.16.2)

See ANNEX 2

Luminaires for mounting on normal flammable surface

No lamp control gear

Lamp control gear spacing:

- spacing 35 mm

- spacing 10 mm

Thermal protection:

- in lamp control gear

- external

- fixed position

- temperature marked lamp control gear

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 9 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.6
(4.16.3)

Design for satisfy the test of 12.6

1.6 (4.17)

Drain holes

Result - Remark

Verdict
P

No drain holes

Clearance at least 5 mm

1.6 (4.18)

Resistance to corrosion:

1.6
(4.18.1)

- rust-resistance

1.6
(4.18.2)

- season cracking in copper

No such part

1.6
(4.18.3)

- corrosion of aluminium

Extrude aluminium use for


luminaire body

1.6 (4.19)

Ignitors compatible with ballast

No ignitors

1.6 (4.20)

Rough service vibration

Not rough service used

1.6 (4.21)

Protective shield:

1.6
(4.21.1)

Shield fitted

1.6
(4.21.2)

Particles from a shattering lamp not impair safety

1.6
(4.21.3)

No direct path

1.6
(4.21.4)

Impact test on shield

Glow-wire test on lamp compartment

Not such luminaire

No attachments

1.6 (4.22)

Attachments to lamps

1.6 (4.23)

Semi-luminaires comply class II

1.6 (4.24)

UV radiation, metal halide lamps

1.6 (4.25)

No sharp point or edges

1.6 (4.26)

Short-circuit protection:

1.6
(4.26.1)

Uninsulated accessible SELV parts

1.6
(4.26.2)

Short-circuit test

1.6
(4.26.3)

Test chain according to Figure 29

1.7 (11)

CREEPAGE DISTANCES AND CLEARANCES

Working voltage (V) ................................................ : 100-240V

Voltage form

No sharp edges

No such parts

Sinusoidal

Non-sinusoidal
PTI

1)< 600

2)> 600
Rated pulse voltage (kV) ....................................... :

Cr.>2.5mm, required 2.5mm


1) Current-carrying parts of different polarity:
cr (mm); cl (mm)...................................................... : Cl.>1.5mm, required 1.5mm

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 10 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

Cr.>2.5mm, required 2.5mm


2) Current-carrying parts and accessible parts:
cr (mm); cl (mm)...................................................... : Cl.>1.5mm, required 1.5mm

3) Parts becoming live due to breakdown of basic


insulation and metal parts: cr (mm); cl (mm) .......... :

4) Outer surface of cable where it is clamped and


No such parts
metal parts: cr (mm); cl (mm).................................. :

5) Not used

Cr.>2.5mm, required 2.5mm


6) Current-carrying parts and supporting surface:
cr (mm); cl (mm)...................................................... : Cl.>1.5mm, required 1.5mm

1.8 (7)

PROVISION FOR EARTHING

1.8 (7.2.1
+ 7.2.3)

Accessible metal parts

Permanently and reliably


connected to the earthing
terminal

Metal parts in contact with supporting surface


Resistance < 0,5

N
0.02

Two self-tapping screws used

Thread-forming screws

Thread-forming screw used in a groove

Earth makes contact first


1.8 (7.2.2
+ 7.2.3)

Earth continuity in joints etc.

1.8 (7.2.4)

Locking of clamping means

No such luminaire

N
P

Earth terminal firmly locked

Compliance with 4.7.3

1.8 (7.2.5)

Earth terminal integral part of connector socket

1.8 (7.2.6)

Earth terminal adjacent to mains terminals

1.8 (7.2.7)

Electrolytic corrosion of the earth terminal

1.8 (7.2.8)

Material of earth terminal

The earth terminal all made of


stainless steel

Contact surface bare metal

Bare metal

1.8
(7.2.10)
1.8
(7.2.11)

1.9 (14)

1.9 (15)

Class II luminaire for looping-in

Double or reinforced insulation to functional earth

Earthing core coloured green-yellow

Green-yellow earthing wire

Length of earth conductor

SCREW TERMINALS

Separately approved; component list

(see Annex 1)

Part of the luminaire

(see Annex 3)

SCREWLESS TERMINALS
Separately approved; component list

N
(see Annex 1)

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 11 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Part of the luminaire

(see Annex 4)

Verdict
N

1.10 (5)

EXTERNAL AND INTERNAL WIRING

1.10 (5.2)

Supply connection and external wiring

1.10
(5.2.1)

Means of connection.............................................. :

Type Z

Connecting leads (EN)

- without a means for connection to the supply

- terminal block specified

- relevant information provided

- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12


and 13.2 of Part 1

1.10 (5.2.2 Type of cable ......................................................... : 60227 IEC52


(H05VV-F)
+ 5.2.4)
Cables equal to HD21 S2 or HD22 S2 (EN)

P
P

Nominal cross-sectional area (mm)...................... :

3x0.75mm

1.10
(5.2.3)

Type of attachment, X, Y or Z

Type Z

1.10
(5.2.5)

Type Z not connected to screws

1.10
(5.2.6)

Cable entries:

- suitable for introduction

- adequate degree of protection

1.10
(5.2.7)

Cable entries through rigid material have rounded


edges

1.10
(5.2.8)

Insulating bushings:

- suitably fixed

- material in bushings

- material not likely to deteriorate

- tubes or guards made of insulating material

1.10
(5.2.9)

Locking of screwed bushings

1.10
(5.2.10)

Cord anchorage:

- covering protected from abrasion

- clear how to be effective

- no mechanical or thermal stress

- no tying of cables into knots etc.

- insulating material or lining

Cord anchorage for type X attachment:

a) at least one part fixed

1.10
(5.2.10.1)

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 12 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

b) types of cable

c) no damaging of the cable

d) whole cable can be mounted

e) no touching of clamping screws

f) metal screw not directly on cable

g) replacement without special tool

Glands not used as anchorage

Labyrinth type anchorages

1.10
(5.2.10.2)

Adequate cord anchorage for type Y and type Z


attachment

1.10
(5.2.10.3)

Tests:

- impossible to push cable; unsafe

- pull test: 25 times; pull (N) ................................... : 60N

- torque test: torque (Nm) ...................................... : 0.25Nm

- displacement 2 mm

0.2mm

- no movement of conductors

- no damage of cable or cord

1.10
(5.2.11)

External wiring passing into luminaire

1.10
(5.2.12)

Looping-in terminals

1.10
(5.2.13)

Wire ends not tinned

Wire ends tinned: no cold flow

1.10
(5.2.14)

Mains plug same protection

Not provided mains plug

Class III luminaire plug

1.10
(5.2.15)

Colour code low voltage (EN)

1.10
(5.2.16)

Appliance inlets (IEC 60320)

Appliance couplers of class II type

1.10
(5.2.17)

No standardized interconnecting cables properly


assembled

1.10
(5.2.18)

Used plug in accordance with

- IEC 60083

- other standard

1.10 (5.3)

Internal wiring

1.10
(5.3.1)

Internal wiring of suitable size and type

Suitable size and type

Through wiring

- not delivered/ mounting instruction

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 13 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

1.10
(5.3.1.1)

Requirement + Test

Result - Remark

Verdict

- factory assembled

- socket outlet loaded (A)....................................... :

- temperatures........................................................ :

Green-yellow for earth only

Internal wiring connected directly to fixed wiring

Cross-sectional area (mm) ................................... :

24 AWG

Insulation thickness

PVC insulation, >0.5mm

Extra insulation added where necessary

Internal wiring connected to fixed wiring via internal current-limiting device

Adequate cross-sectional area and insulation


thickness

1.10
(5.3.1.3)

Double or reinforced insulation for class II

1.10
(5.3.1.4)

Conductors without insulation

1.10
(5.3.1.5)

SELV current-carrying parts

1.10
(5.3.1.6)

Insulation thickness other than PVC or rubber

1.10
(5.3.2)

Sharp edges etc.

1.10
(5.3.1.2)

No sharp edges or other


damages to supply cords

No moving parts of switches etc.

Joints, raising/lowering devices

Telescopic tubes etc.

No twisting over 360

Insulating bushings:

- suitable fixed

- material in bushings

- material not likely to deteriorate

- cables with protective sheath

1.10
(5.3.4)

Joints and junctions effectively insulated

1.10
(5.3.5)

Strain on internal wiring

1.10
(5.3.6)

Wire carriers

1.10
(5.3.7)

Wire ends not tinned

1.10
(5.3.3)

Wire ends tinned: no cold flow

Not cold flow

1.11 (8)

PROTECTION AGAINST ELECTRIC SHOCK

1.11
(8.2.1)

Live parts not accessible

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 14 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

Basic insulated parts not used on the outer surface Basic insulated parts are
without appropriate protection
earthed

Protection in any position

Double-ended tungsten filament lamp

No double-ended tungsten
filament lamp used

Insulation lacquer not reliable

No insulation lacquer used

Double-ended high pressure discharge lamp

No double-ended high
pressure discharge lamp

Relevant warning according to 3.2.18 fitted to the


luminaire

1.11
(8.2.2)

Portable luminaire adjusted in most unfavourable


position

1.11
(8.2.3)

Class II luminaire:
- basic insulated metal parts not accessible during
starter or lamp replacement

1.11
(8.2.4)

--Class l luminaire

- basic insulation not accessible other than during


starter or lamp replacement

- glass protective shields not used as


supplementary insulation

Class I luminaire with BC lampholder

Portable luminaire:

- protection independent of supporting surface

Fixed luminaire not applicable

- terminal block completely covered

1.11
(8.2.5)

Compliance with the standard test finger or


relevant probe

1.11
(8.2.6)

Covers reliably secured

Reliable fixed

1.11
(8.2.7)

Discharging of capacitors 0,5 F

No plug

1.12 (12)

Portable plug connected luminaire with capacitor

Other plug connected luminaire with capacitor

Discharge device on or within capacitor

Discharge device mounted separately

ENDURANCE TEST AND THERMAL TEST

1.12 (12.3) Endurance test:

- mounting-position ................................................. : Normal operation, most


unfavourable position

- test temperature () ............................................ : 35+2

- total duration (h).................................................... : 168h

- supply voltage: Un factor; calculated voltage (V) . : 1.1 times rated voltage

- lamp used ............................................................. : LED lamps in luminaire

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 15 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.12
(12.3.2)

After endurance test:

- no part unserviceable

- luminaire not unsafe

- no damage to track system

Result - Remark

No track system provided

Verdict

- marking legible

- no cracks, deformation etc.

1.12 (12.4) Thermal test (normal operation)

(see Annex 2)

1.12 (12.5) Thermal test (abnormal operation)

(see Annex 2)

1.12 (12.6) Thermal test (failed lamp control gear condition):

1.12
(12.6.1)

Through wiring or looping-in wiring loaded by a


current of (A) .......................................................... :

- case of abnormal conditions................................. :

- electronic lamp control gear

- measured winding temperature () at 1,1 Un ..... :

- measured mounting surface temperature () at


1,1 Un ..................................................................... :

- calculated mounting surface temperature () ..... :

- track-mounted luminaires

Temperature sensing control

- case of abnormal conditions................................. :

- thermal link

- manual reset cut-out

- auto reset cut-out

- measured mounting surface temperature () .... :

- track-mounted luminaires

1.12
(12.6.2)

1.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires):

1.12
(12.7.1)

Through wiring or lopping-in wiring loaded by a


current of (A) ........................................................... :

- case of abnormal conditions................................. :

- measured winding temperature () at 1,1 Un ..... :

- measured temperature of fixing point/ exposed


part () at 1,1 Un ................................................... :

- calculated temperature of fixing point/ exposed


part ()................................................................... :

Temperature sensing control

- thermal link

- manual reset cut-out

- auto reset cut-out

1.12
(12.7.2)

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 16 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

- measured temperature of fixing point/ exposed


part () .................................................................. :

1.13 (9)

RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE

1.13 (9.2)

Tests for ingress of dust, solid objects and moisture:

- classification according to IP ................................ : IP20

- mounting position during test................................ : Most unfavourable position

- fixing screws tightened; torque (Nm).................... : 2/3 rated torch

- tests according to clauses .................................... : IEC 60529

- electric strength test afterwards

a) no deposit in dust-proof luminaire

b) no talcum in dust-tight luminaire

c) no trace of water on current-carrying parts or


where it could become a hazard

d) i) For luminaires without drain holes no water


entry

d) ii) For luminaires with drain holes no


hazardous water entry

e) no water in watertight luminaire

f) no contact with live parts (IP 2X)

f) no entry into enclosure (IP 3X and IP 4X)

f) no contact with live parts (IP3X and IP4X)

1.13 (9.3)

Humidity test 48 h

48h, 25, 93%

1.14 (10)

INSULATION RESISTANCE AND ELECTRIC STRENGTH

1.14
(10.2.1)

Insulation resistance test

Cable or cord covered by metal foil or replaced by No cable


a metal rod of mm .............................................. :

Insulation resistance (M):

SELV:

- between current-carrying parts of different polarity


............................................................................... :

- between current-carrying parts and mounting


surface ................................................................... :

- between current-carrying parts and metal parts of


the luminaire .......................................................... :

Other than SELV:

- between live parts of different polarity................. :

>2M

- between live parts and mounting surface............ :

>2M

- between live parts and metal parts...................... :

>2M

- between live parts of different polarity through


No switch
action of a switch ................................................... :

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 17 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

1.14
(10.2.2)

Electric strength test

Result - Remark

Verdict
P

Dummy lamp

Not such lamp

Luminaires with ignitors after 24 h test

No ignitors

Luminaires with manual ignitors

No manual ignitors

Test voltage (V):

SELV:

- between current-carrying parts of different polarity


............................................................................... :

- between current-carrying parts and mounting


surface ................................................................... :

- between current-carrying parts and metal parts of


the luminaire .......................................................... :

Other than SELV:

- between live parts of different polarity................. :

1480V/1min, no broken

- between live parts and mounting surface............ :

1480V/1min, no broken

- between live parts and metal parts...................... :

1480V/1min, no broken

- between live parts of different polarity through


No switch
action of a switch ................................................... :

1.14
(10.3.1)

Leakage current (mA) ............................................ :

1.15 (13)

RESISTANCE TO HEAT, FIRE AND TRACKING

1.15
(13.2.1)

Ball-pressure test:

- part tested; temperature () ............................ :

1.15
(13.3.1)

lampshade, 75, 0.8mm

- part tested; temperature () ............................ :

Needle flame test (10 s):

lampshade, tested and


passed

- part tested; temperature () ............................ :

- part tested; temperature () ............................ :

Glow wire test (650 ):

- part tested............................................................ :

lampshade, tested and


passed

- part tested............................................................ :
1.15
(13.4.1)

- part tested; temperature () ............................ :

- part tested; temperature () ............................ :

1.15
(13.3.2)

Class l luminaire, <1.0mA,


tested and passed

Tracking test: part tested ....................................... :

P
N

Ordinary luminaries

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 18 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

ANNEX 1: components
object/part No.
Cable

code
A

manufacturer/
trademark
Shenzhen Bao
Hing Electric
Wire

type/model

technical data

standard

H05VV-F

Min. 3 X 0.75
mm2, 300/500V

IEC60227

20AWG, 105C ,
300V

UL758

Test in
appliancce
(UL)

EN61347-1

CE

Internal wire

Various

Various

Electronic
control gear for
LED lamps

FOZZ

EWP-50-1.4A i/p: 100-240V~,


50/60Hz, 0.6A;

Translucent
cover

mark(s)
of
f
VDE
131689

EN61347-2-13

o/p: Max. 36Vdc,


1.4A
SABIC
FR60
INNOVATIVE
PLASTICS
CHINA CO LTD

PC

EN60598-1

Test in
appliance
(UL)

The codes above have the following meaning:


A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component

ANNEX 2: temperature measurements, thermal tests of Section 12

Lamp used ............................................................. :

SL-PAN-50W-WW/NW/PWAN/LS
LED lamps in luminaire

Lamp control gear used ......................................... :

Ewp-50-1.4A

Type reference ....................................................... :

Normal use, most


unfavorable position
Supply wattage (W)................................................... : 52W
Mounting position of luminaire ............................... :

Supply current (A) ................................................... : 0.216A


Calculated power factor............................................ :

0.93

Table: measured temperatures corrected for ta = 25 C:

- abnormal operating mode.................................... :

- test 1: rated voltage ............................................. :

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 19 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

- test 2: 1,06 times rated voltage or 1,05 times rated


wattage .................................................................. :

1,06 X 240V=254V

- test 3: Load on wiring to socket-outlet, 1,06 times


voltage or 1,05 times wattage ................................ :

--

- test 4: 1,1 times rated voltage or 1,05 times rated


wattage .................................................................. :
Through wiring or lopping-in wiring loaded by a
current of (A) during the tests ................................ :

--

clause 12.4 normal


test 1

test 2

test 3

limits

clause 12.5
b
l
test 4

Input cable, nearest to power unit

24.8

105

Internal wire, nearest to lamp

27.1

105

LED negative position, represent


for PWB
Enclosure, power unit

38.5

Ref.

45.4

Ref.

Enclosure, luminaires

43.2

90

*
-

Ambient

25.0

temperature (C) of part

limit

*Comments: not measured for Non-combustible surface

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 20 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

ANNEX 3: screw terminals (part of the luminaire)

(14)

SCREW TERMINALS

(14.2)

Type of terminal ..................................................... :

Approved power unit used

Rated current (A) ................................................... :

(14.3.2.1)

One or more conductors

(14.3.2.2)

Special preparation

(14.3.2.3)

Terminal size

Cross-sectional area (mm) ................................... :

(14.3.3)

Conductor space (mm) .......................................... :

(14.4)

Mechanical tests

(14.4.1)

Minimum distance

(14.4.2)

Cannot slip out

(14.4.3)

Special preparation

(14.4.4)

Nominal diameter of thread (metric ISO thread).... :

External wiring

No soft metal

(14.4.5)

Corrosion

(14.4.6)

Nominal diameter of thread (mm) .......................... :

Torque (Nm)........................................................... :

Between metal surfaces

Lug terminal

Mantle terminal

Pull test; pull (N)..................................................... :

Without undue damage

ANNEX 4: screwless terminals (part of the luminaire)

(15)

SCREWLESS TERMINALS

(15.2)

Type of terminal ..................................................... :

(14.4.7)

(14.4.8)

Approved power unit used

Rated current (A) ................................................... :

(15.3.1)

Material

(15.3.2)

Clamping

(15.3.3)

Stop

(15.3.4)

Unprepared conductors

(15.3.5)

Pressure on insulating material

(15.3.6)

Clear connection method

(15.3.7)

Clamping independently

(15.3.8)

Fixed in position

(15.3.10)

Conductor size

Type of conductor

Terminals internal wiring

(15.5.1)

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 21 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

(15.5.1.1)

Pull test spring-type terminals (4 N, 4 samples)

(15.5.1.2)

Pull test pin or tab terminals (4 N, 4 samples)

Insertion force not exceeding 50 N

(15.5.2)

Permanent connections: pull-off test (20 N)

(15.6)

Electrical tests

Voltage drop (mV) after 1 h (4 samples) ............... :

Voltage drop of two inseparable joints

Number of cycles ................................................... :

Voltage drop (mV) after 10th alt. 25th cycle


(4 samples) ............................................................ :

Voltage drop (mV) after 50th alt. 100th cycle


(4 samples) ............................................................ :

After ageing, voltage drop (mV) after 10th alt.


25th cycle (4 samples)........................................... :

After ageing, voltage drop (mV) after 50th alt.


100th cycle (4 samples)......................................... :

Terminals external wiring

Terminal size and rating

Pull test spring-type terminals or welded


connections (4 samples); pull (N) ......................... :

Pull test pin or tab terminals or welded connections


(4 samples); pull (N) ............................................. :

Contact resistance test

Voltage drop (mV) after 1 h

(15.7)
(15.8.1)

(15.9)
terminal

Result - Remark

Verdict

10

voltage drop (mV)


Voltage drop of two inseparable joints
Voltage drop after 10th alt. 25th cycle

Max. allowed voltage drop (mV) ......................... :

terminal

10

voltage drop (mV)


Voltage drop after 50th alt. 100th cycle

Max. allowed voltage drop (mV) ......................... :

terminal

10

voltage drop (mV)


Continued ageing: voltage drop after 10th alt. 25th cycle

Max. allowed voltage drop (mV) ......................... :


terminal

10

voltage drop (mV)


Continued ageing: voltage drop after 50th alt. 100th cycle

Max. allowed voltage drop (mV) ......................... :

terminal

10

voltage drop (mV)


Accurate Technology Co. Ltd.
Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 22 of 26

Report No.: ATS2011727

IEC 60598-2-2 and/or EN 60598-2-2


Clause

Requirement + Test

Result - Remark

Verdict

ANNEX 5: National Differences for (country name) or Group Differences

CENELEC COMMON MODIFICATIONS (EN)

1.5 (3)

MARKING

1.5 (3.3.101)

Adequate warning on the package

1.10 (5)

EXTERNAL AND INTERNAL WIRING

1.10 (5.2.1)

Connecting leads

- without a means for connection to the supply

- terminal block specified

- relevant information provided

- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2,


12 and 13.2 of Part 1

1.10 (5.2.2)

Cables equal to HD21 S2 or HD22 S2

ZB

ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN)

(3.3)

DK: power supply cord with label

IT: warning label on Class 0 luminaire

(4.5.1)

DK: socket-outlets

(5.2.1)

CY, DK, FI, SE, GB: type of plug

ZC

ANNEX ZC, NATIONAL DEVIATIONS (EN)

(4 & 5)

FR: Shuttered socket-outlets 10/16A

(13.3)

DK: Needle flame test during 30 s

(13.3)

GB: Requirements according to United Kingdom


Building Regulation

(13.3.2)

FR: Glow-wire test 850 alt. 750 for luminaires


in premises open to public or 960C for
luminaires in emergency exits

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 23 of 26

Report No.: ATS2011727

Appendix 1
Equipment List
No.

Equipment

01 Hybrid Recorder
02 Hybrid Recorder
Data Acquisition / Switch
03
Unit
Data Acquisition / Switch
04
Unit
05 Temp. & Humid. Chamber
06 Oven Chamber
14 Oscilloscope
15 Digital Power Meter
16 Digital Power Meter
17 Digital Power Meter
18 Ohm Meter
19 Multi Meter
21 Desktop Multi Meter
22 Desktop Multi Meter
23 Desktop Multi Meter
24 Desktop Multi Meter
25 Hi-Pot Tester
26 Grounding Bond Meter
27 Leakage Current Meter
28 Touch Current Meter
Insulation Resistance
29
Tester
30 Digital Power Meter
31 Electronic Scale
32 Push-Pull Scale
33 Test hook

Manufacturer

Model No.

Serial No.

Calibration Calibration
date
due date

Yokogawa
Yokogawa

DR130
DR130

27D216293
27D216294

2011.01.04
2011.01.04

2012.01.03
2012.01.03

Agilent

34970A

MY41027365

2011.01.04

2012.01.03

Agilent

34970A

MY41025924

2011.01.04

2012.01.03

Gongwen
Rongfeng
Tektronix
Qingzhi
Ainuo
Everfine
Yang Zi
Fluke
Good Will
Fluke
Good Will
Good Will
Ainuo
Ainuo
EXTECH
EPRE

HSD-500
101A-3
TDS3012B
8716C
8715B
YF9901
YD2511
111
GDM-8245
45
GDM-8245
GDM-8245
9604
9613B
7611
400C

0109
900875
B035855
870307119
038710069
405075
794
85150263
E900535
8392013
E830573
E830574
039609405
039606212
1330308
0402A05

2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03

Yang Zhi

YD2683

030

2011.01.04

2012.01.03

Qingzhi
Heng Tong
Japan
Instrumentation
Zhilitong

8716C
J3S5

870307126
18514

2011.01.04
2011.01.04

2012.01.03
2012.01.03

NK-300

49779

2011.01.04

2012.01.03

TH-1
(0~150mm)/0.0
1mm
(0~150mm)/0.0
1mm

W8L180T1

2011.01.04

2012.01.03

27452

2011.01.04

2012.01.03

27460

2011.01.04

2012.01.03

Oregon

JB913R

06A03-4101

2011.01.04

2012.01.03

Wenzhou
Zhilitong
Good Will
DM
Zhilitong
Zhilitong
Zhilitiong
Zhilitong
Zhilitong
Zhilitong
America
Zhilitong
Zhilitong
Zhilitong
Zhilitong
Zhilitong
Zhilitong
All Power
Chuang Hong
Kong Tel

JZC-B2
GT-1
GAG-810
DM8898
LJ-1
ZP-1
ZT-1
ZJ-1
ZF-1
ZA-1
ULP-01
TZ-1
TZ-11
TZ-12
TZ-13
TZ-14
ZB-1
IP50-20D
CPS-5030D
5KVA

15032
G010104
D913311
D826715
LJ010104
44/ATCS-44
D30L80/ATCS-45
D14N30/ATCS-46
X010106/ATCS-47
A010102/ATCS-48
A01/ATCS-49
L010304
D4L100/ATCS-51
D3L100/ATCS-52
D1L20/ATCS-53
D40/ATCS-54
D5W500
401024
04021101
002

2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03

34 Digital Caliper

Guang Lu

35 Digital Caliper

Guang Lu

36
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
58
59
60

Electronic ThermoHygrometer
Goniometer
Tumbling Barrel
Audio Generator
Noise Generator
Plug Torque Tester
Shot Test Pin Probe
Test Probe 41
Finger Nail Probe
Test Finger Probe
Accessibility Probe
UL Finger Probe
Rigid Finger Probe
Test Probe
Test Probe
Test Probe
Test Probe
Steel Ball
DC Power Supply
DC Power Supply
Isolating Transformer

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 24 of 26
No.

Equipment

61 Hammer
62 Hammer
63 Hammer
64
65
66
67
68
69
70
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
E30
E53
E54
W1
W2

Manufacturer
Guangdong
Zhijian
Zhilitong
Guangdong
Zhijian
Zhilitong
kanon
kanon
Sanke Electrical
Sanke Electrical

Report No.: ATS2011727

Model No.

Serial No.

CJ-2

24003

2011.01.04

2012.01.03

CJ-2

C021204

2011.01.04

2012.01.03

CJ-2

24004

2011.01.04

2012.01.03

C021104
04C175
04A037
31208433081
31208455481

2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03

890411

04454

ATCS-73

350400004

18955
ATCS-76
AT24H
870512009
870512012
301020
280887

2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03

MY44008068

2011.01.04

2012.01.03

R024007
Y021507
200609812
ATE868205164

2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03

G290700126

Q013408/ATCS-88
Q013508/ATCS-89

2011.01.04
2011.01.04

2012.01.03
2012.01.03

23489-6

2011.01.04

2012.01.03

ATCS-91
ATCS-92
ATCS-93
ATCS-94
DAMS2009110136

2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03

TI09101201

2011.01.04

2012.01.03

10-866030

2011.01.04

2012.01.03

090074695

2011.01.04

2012.01.03

0907005
12VC26618M
7664009
272
B-0138
B-0137

2011.01.04
2011.01.04
2011.01.04
2011.01.04
2011.01.04

2012.01.03
2012.01.03
2012.01.03
2012.01.03
2012.01.03

2011.01.04

2012.01.03

2011.01.04

2012.01.03

2011.01.04

2012.01.03

Hammer
CJ-2
Torque Driver
30LTDK
Torque Driver
12LTDK
AC Voltage Stabilizer
SVC-30KVA
AC Voltage Stabilizer
SVC-30KVA
Frequency Converter Power
All Power
AFC-220
Supply
Frequency Converter Power
NewG Power
Ng-3120a
Supply
High-voltage Passive Probe
TEXAS
HVP3011
Switching Mode Power
Manson
SIM-9106
Supply
Tape line
Great Wall
GW-589E
Platform Scale
Shanghai
TGT-100
Timer
Tian Fu
PC396
Digital Power Meter
Qingzhi
8716C
Digital Power Meter
Qingzhi
8716C
Digital Power Meter
Everfine
PF9805
Digital Power Meter
iDRC
CP-280
Data Acquisition / Switch
Agilent
34970A
Unit
Glow Wire Test Set
Zhilitong
GTR-B
Needle Flame Test Set
Zhilitong
ZY-2
Hi-Pot Tester
Changsheng
CS5051
DC Electronic Load
Techred
TR-868
Switching Mode Power
Manson
SIM-9303
Supply
Ball Pressure Tester
Zhilitong
QY-1
Ball Pressure Tester
Zhilitong
QY-1
Oscilloscope voltage probe
Tektronix
P5100
(100X)
K type thermocouple
OMEGA
TT-K-30-1000
J type thermocouple
OMEGA
TT-J-30-1000
Small finger probe (8.6)
HUANAN
EX-A02
Small finger probe (5.6)
HUANAN
EX-A02
Draught-proof enclosure
Shanghai Jingtian
DMS-B12
Proof tracking Test
Shenzhen
LD-H
Apparatus
Demaisheng
228 meter
SIMPSON
228
(0~150mm)/0.0
Digital Caliper
Guang Lu
1mm
Torque Driver
Kanon
10DPSK
Digital Power Meter
Yokogawa
WT110
Desktop Multi Meter
Fluke
45
LCR bridge
YANGZHI
YD2810B
Exposure level tester
NARDA
2304/03
Magnetic field probe
NARDA
2300/90.10
100cm2
Digital Vibration Tester
Beijing
ACT2000Zhongyuan
S20L-MI2240L
SCD-88
Surge Tester
Wuhan HighVoltage Research
Institute

V98662050
20011

Calibration Calibration
date
due date

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 25 of 26

Report No.: ATS2011727

Appendix 2
Photo documentation

PHOTO 1
View:
SL-PAN-50W-NWAN
[ ] front
[

] rear

] right side

] left side

] top

] bottom

] internal

PHOTO 2
View:
SL-PAN-50W-NWAN
[

] front

] rear

] right side

] left side

] top

[ ] bottom
[

] internal

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com

Page 26 of 26

Report No.: ATS2011727

Photo documentation

PHOTO 3
View:
Power unit
[

] front

] rear

] right side

] left side

] top

] bottom

[] internal

PHOTO 4
View:
Power unit
[

] front

] rear

] right side

] left side

] top

] bottom

[] internal

Accurate Technology Co. Ltd.


Address: F1,Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,Nanshan District, Shenzhen 518057 ,P. R. China.
Tel: +86-755-26503290 Fax: +86-755-26503396 E-mail: webmaster@atc-lab.com Http://www.atc-lab.com