Vous êtes sur la page 1sur 17
TRV Brea THE ENERGY SAVING AIR CONDITIONING SYSTEM * DC Inverter Water Cooled System ouiton Beyond Comfort TDVW -(M) 4 Series Technologies PB sHieni ena Grey Saving (Compact Size (Gite Combination (Sihpiiies Installation (Gimare Reliability Geeite sues seekers The Reluctance Brushless Reluctance DC Inverter compressor operate with high efficiency (EER), fast startup response and less energy consumption to save your electricity charges, The motor comprises powerful neodymium magnets, that create the reluctance torque. These magnets are approximately 12 times stronger than the normal ferrite magnets and make a major contribution to reduce operation noise, compressor size, compressor weight and energy saving characteristics. The Inverter Compressor is operate in superior performance with improved middle frequency range (35-75 Hz ), combination with the multi constant speed scroll compressor in the system circult ‘Able to attain varies capacity range between 15 ~ 130 %, depending on the partial and loading required capacity New structure for improved middle frequency range ‘Specially designed scroll profile for 410A, More compact, weight reduced by 50% ‘Advanced powerful neodymium magnets 2. Smooth 180° Sine Wave DC Inverter © Optimizing the sine wave curve, resuits in smooth motor retation and improved motor efficiency. 180? Sine Wave DC inverter ‘Common sawtooth wave 3. Digital PCB Electrical Control © Provided DC inverter compressor soft starter function to minimize power fluctuation on the power system, © Builtin3 phase power protector to protect compressor operate form abnormal power supply condition, whereby itmay cause damage to the compressor. (© New improved Auto Oil Return Program run for 15 minutes on oll lubrication for the compressor systern, CRs MAL Ad ei (ot oo © Consist of outer copper tube with internal corrugated Tweeut copper finned tube. Zz ery 8 hours operation cycle to ensure sufficient © Each condenser is built with intergral sub-cooling to maximize system efficiency and fully tested up to 450 psig. © Circuit design with'two in two out less water pressure drop Zz and more surface area ensure better heat transfer. eee ET Ee ole Bola ta alcool © High efficiency centrfugal ol separator built in the refrigerant circuit to improves ol separation efficiency up to 99% of cil migration and refrigerant pressure drop in the system. (© The builtin suction accumulator is cater for maintain the compressor reliability due to long piping length and. high refrigerant volumn application, 6. Benefits of using R 410A Refrigerant @ Reduce CO” emisions and prevent global warming, @ Zero ozone-depleting potential. © Significant increase in energy efficiency and improved performance. Wide Ambient Operation Range D> stiendy : 'FRAIOA © Designed Cooling Mode aperation max. up to 40°C & min. down to 10°C ; ambient water temperature. © Standard Cooling Mode aperation"inlet 30°C / Outlet 35°C"; ambient water temperature Ure cies SErieuneiacue er meee @ Inthe event of equal lifespan among the combine outdoor units, any one of the outdoor unit can sequentially random self adjust as master unit. ‘sive? ‘stave? Eerie ia aren © In the muttipte combination outdoor system, if one of the outdoor unit faulty or compressor malfunction. Other slave units will keep on operating. The faulty unit can be set as standby state by adjusting * DIP switch in the ‘outdoor POB control at field, Precise Comfortable Temperature Control > sHienay 'FAIOA ‘The thermostat can control stable room temperature at + 0.5°C form set point. © Anelectrinic expansion valve is continuously adjust the refrigerant flow volume in respond to load variation of the indoor units. © The DC inverter air conditioner system maintains comfortable room temperature at a virtually constant level, ‘without the typical temperature variations that occur of conventional ON/OFF air conditioner system. cooling operation var power contel 20) [Bi Nar tnorar pe i eontonar 3.76) Easy Maintenance © Self diagnosis function-operated via push button on the PCB with display "malfunctions code" or "operation status code" able to speeds up troubleshooting and maintenance, Remote Addressing BY Automatialy Wentiy © Addressing indoor units by wireless remote controler. (Maximum up to 59 indoor/group) Ler IETS ‘Top Class performance EER = §.40( 8 HP). ‘Wider Combination range for one system (up to 36 HP), greater application flexbily. 3 basic modules ( 8p, 10 hp, 12hp ) can be freely combined, Max. piping length (up to 120 m). Max. connectable indoor units ( up to 59). EER in Cooling 540 * EER = Capacity [kW] / Power Comsumption [kW] a ©: 'ARAIOA How to Read the Models Condenser - Outdoor Unit ~~ Refrigerant 4-RAIOA Type Of Outdoor M.- Modular Outdoor worn enn--H- Model Code hen-------------- TOPAIRE DC TYPE VRF INVERTER WATER COOLED Evaporator - Indoor Unit Trovit C4 oe ee tat b+ --Rettigerant 4-RAIOA == =+Generation Series ‘Type Of Indoor WM -WALL MOUNTED CCS -COMPAGT 4 WAY CASSETTE S -4WAY CASSETTE CF -CELING/FLOORCONVERTBLE CR -LOWSTATIC DUCTED EB MEDIUM STATIC DUCTED Model Code wee rrre rc nn noon TOPAIRE DC TYPE VRF INVERTER Wide Application R: > steady 08 Py AWM Ma ocd et ar acer ET (820,22 “16,18, 20,22, 2442 26,28, 30, 32,34, 36 HP Design ae ere ll leercracieenoen| mesa a ae #9000 | TDVW 80M4 8 13 2 100500 | TOVW100M4 10 16 = 20200 |TOVW120M4 12 16 178,000 = |TOVW160M4 848 B 199500 |TOVW180M4 8+10 2 201,000 |TOVW200 M4 10+10 3 20700 |TOVW220M4 | t0+12 6 240400 |TOVW240M4 | 12+12 8 275000 |TOVW260M4 | 8+8+10 8 290,000 |TDVW280M4 | 8+ 10+10 48 301500 |TDVW300M4 | 10+ 10+10 50 321,200 |TDVW320M4 | 10+ 10+12 53 340900 |TOVW340M4 | 10+12+12 56 360,600 |TDVW360M4_ | 12+12+12 59 "pear eye To age pata a Nite nora cng copys tandem cons a ing n 35 Coron eter 277908748) Technical Specifications > tiene TDVW -M 4 Single Modules [Cocing Capacty Henin Open = : IDC Inverter, Compressor |Oper. Frequency Lubricant Oi! | Type/m Waterflow volume | Heat Exchanger [Pressure drop Max pressure of pe ice Comet Noise level 1) IRefiigerant hl INet dimension INet weight WD mmm Liuid side mre Suction side mnminch ) Oil balance pipe | rintinch Pipe Diameter @ 404200 FVD 680 /500 6 ape 127( 12) 2B6(118) 64 (14) 159/88) 318(1 14) a) (Cootng Capacty (Btu!) 10 | sone | pm | sana | ago | nn | som | enn | ae | see sso | ene Compactcassete » e © e@ © ®» foramen ee a0 0/00 wines |@|@/@\0\0\0 Cog ane ee @VIVWWIVIOO Low state prssure wet | O|B|\O O/B VVe (ESP:02~03ing) Mesum sac pressure ued aeo/0 (£8: 05ing) ium stati prassure (ESP: 05inng) doen e Modan ste pressure ced (ESP: 08g) Gaag il ‘specanensare sje o ange mantacise hau po note Nate: Theremin eostng pact teed on cena eutdooro enw tm. 35°C Ondearon cle. 27/19% (00/8) Ane) calito >: Precis Speccatons REO Cees Features, © New 260° air distribution outlet panel with auto air ewing ( Up & Down @ Standard 850x 650 mm unifed square air discharge panel €@ Sim, siyish with removable easy clean air titer grille and discharge pane! © Low noise lavel range 22~28 dB(A) at lw fan speed © LED indicator light display panel and auto restart function. {© Evaporator coll with anti-corrosion hydrophilic coated sit fr €@ Acroaynamic turbo fan to enhance strong air low for better ar ctculation © EXV thrtte kt box attach to unit casing main body. € Builtin drain pump to boost condensate water discharge. © Antimold and long lasting washable saran net ar fier. aor 70 Tar Taam Jooauns carey Tar Ew a Ba 5 SUA EE TASES ED FONER FUT ci a ra 5 a TED AIPERE TF 3 Ti Tai 331 faserranr ea i Taal | ar | — a | — TT RSuNCevEr THT am ASE Bae OTT OT m3 atk Tao Rao Raok eee “CONTROL DEVICE. EXV EXV XV EX BEE comECTON Tau sate ar sae a mir SUETOW Tey Tac are Tay PRE ama BOUT} ao a BOUT} Pret ouESorm) —[ WNIT woe) | eaxeaxe | —eaxen xn | —saxeays | eaxeaxs [Smee CRT anasto TRE et Erne a z z 7 z Four-way Cassette Features © Now 260° air distribution outlet panel with auto air swing ( Up & Down } {© Standard 950x 950 mm unified square air discharge pane! @ Sim, styish with rerrovable easy clean air filer gle and discharge pare! © Low noise level ange 35~44 dB(A) at low fan speed. © LED indicator with cigtal temperature display panel and auto restart function (© Evaporator coll with anti-corrosion hydrophilic coated sit fn, € Aerocynamic turbo fan to enhance strong airflow for better ar circulation © EXV throttle kt box attach to unit casing mein body. € Builtin drain purnp to boost condensate water discharge. © “Anti-mold end long lasting washable saran net air iter. Toine | waser | wonmer | =a a zee [a eT cn i ‘Aspetaersre sje chngedy manta tha po noe Note: Theremin eosin pacts bsndonconderon eden enteing tng. 35 (0indear on cltenp.27/9°C(08/W8) 10 chnical Specifications > stienay oy Features. © Twotype of front cleplay panel ( Snow white / Black) colour for choose. © Aicdistribution with auto air swing ( Up & Down )/ manual (Let & Right). © Low noise level range 29 ~ 36 dB(A) at ow fan speed © LED indicator with cigtal temperature display panel and auto restart function © Evaporator coll with ant-coresion hydrophilic coated sit fn © Cross flow fan to enhance strong ar flow for better air circulation, © Bult n EXV that kt © Anti mold and long lasting washable saran net air itr. fesounscamorr “3 Be ci ce a fon 5 Ta “Ear oHy Ceiling and Floor Features © Converibo coling suspended of floor mounted un versatile fr instalaton 5 © Compact sim casing design with 200 mm height = (13,000 ature ~ 36,000 ums ) x 240 men height ( 40,0008tu/hr ~ 50,000 tut fr easy instalation 4 nay air cistbution wth auto air swing (Up & Down ) (Left & Right). Low noise level ange 36-44 dB(A) at iw fon speed LED ncicator ight splay pane and auto restart unetion Evaporator col wth ant-corosin hyropile coated sit fins. Centrtugal fen to enhance strong alr ow for beter alr ccuation. Buin EXV thee kt Ant-old and long lasing washable saran neta ter, Ferre r ‘Aspeeersre sje changed manta the po note 41, toe: Trent conc nbn cndeow ensure emeing tener ndorencltenp.2719°(0B/NB) aon eee) sais >: Precis Spectcatons REO Red See acl Features, ‘© Compact slim casing design with 210 mm height (8,000 Btuhr~20,000 Btuth) (0270 mm height (25,0008tu50,000 Btu/hr) for easy instalation (© External static pressure operating range 0.2 ~ 0:3 ing, © Low nciee level range 32~38 dB(A) at low fan speed. © LED indicator light display panel and auto restart function. © Evaporator coll with anti-corrosion hydrophilic coated sit rs © Centrifugal fan to enhance stiong airflow fer beter ar ciculation © Bultin EXV thrott kit © Durable electo-galvanized steel casing €@ Antiamold and long lasting washable saran net ar iter © Optional buit in drain pump to boost condensate water discharge Medium Static Pressure Ducted Features © External static pressure operating range 0.5 inwa. (25,000 Btuthr ~ 60,000 Btufhr) © External static pressure operating range 0.8 inwg. (72,000 Btuthr~ 100,000 Bturr) © Low noise level range 44~52 d8(A) at low fan speed. © LED indicator light display panel and auto restart function © Evaporator coil with anti-corrosion hydrophilic coated st fins. © Centrifugal fan to enhance strong eirfovr for better air circulation. £ © Bui in EXY throttle kt (25,000 Btu ~ 60,000 Btu ) © EXV throttle kt box attach to unt easing main body. (72,000 Btuthe ~ 100,000 Btu ) © Durable electo-galvanized steel casing €@ Anti-mold end iong lasting washable saran net ar iter. Aspeeatens re svbjeo ngety manta thou pr note Note! The nomi cost epacy buen conten uaa emengtmp. 5%C nde on cep. 27/19 (00/18) 2 B coca WTS g &. ey 28 om SS Heat recovery mode (ttm ae trom room) SA Damper a ‘The TOPAIRE heat recovery vetlation system modulates the temperture and humidity of incoming fresh air to match indoor condition, Reclaim heat energy lost through ventilation and reduce the room temperature cause by ‘Stpow ar ventilation process, teroom A balance is thus achieved between indoor and outdoor ‘ambients, enabling the cooling load placed on the air conditioning system to be reduce significantly. ‘THRV units can be controlled individually or integral with the air conditioning system ( TOPAIRE TDVI - M 4, TDVI - S4 ‘and TDVI- MS4)) by interlocking with the Centralized Control (CCM 03). Bypass ventlation made Damper cAee Features © Compact, easy installation and energy saving ventilation, © Temperature exchange eficiency is above 65%. © Enthalpy exchange efficiency is between 50 ~ 65%, €@ Thrve fan speed fo the model THRY 100 ~ THRV 600. €@ Single fan speed for the model { THRV 900 ~ THR 1200 }. © External static pressure operating range 0.3 ~ 0. inwg © Special heat exchange element with HEP ( High Efficiency Paper). @ Dual Mode provided ( Hest recovery mode / Bypass ventilation mode ) He Poesfize] m Poosfuoe] [omafion| H1Jueeficol Jo] on] HJuedfion] Shae Smee | Sra Somes [Forme = [T=] =] =] = 12] =] [21212 =e = [remrenaran A ET FF 7110576) 8 RESTOR TEP STO (OST VE) SOR RT Atspeeersre sje changed manta thet ponte Note: Theremin cosines tue connotea enteingtng. 35° adoro cle. 219° (00/8) la Light background, LCD display screen, clock function, ON/OFF/Temperature setting! Mode setting /Fan speed setting/horizontal swing/vertical swing setting functions, but need match functions with corresponding indoor units. = arr ore Tey ONIOFF/Mode setting/Temp. setting/Fan speed setting/Time setting/Swing, ete... ON/OFF /Mode setting/Temp. setting/Fan speed/Time setting/Swing, etc. ‘The basic function is the same as KJR-10B, Temp sensor builtin. Note:Special order for indoor PCB. Centralized ls Max. 16 indoor units control ‘Max. 64 indoor units control; New mode lock function, Max. 32 outdoor units control. Note: Special order for outdoor PCB. oy 3 fore el [ete > -Hienay Sa /RATOA’ Petite racer ek AoE coo Control up to 64 indoor units Network control software (V3.0). BACNET LONWORK /ETHERNET optional, Max connecting 4 group air-conditions (each group can connect Max. 64 indoor units or 32 outdoor units). in Support Software This advanced software is designed to be customizable to make any selections and design processes in a quick and easy way. The design software utilises system wizards and import tools to enable both simple and complex systems to be created. In addition, the system will allow outdoor and indoor units to be dragged and dropped on a interactive desktop. This allows users to create everything from realistic floor plans with detailed with piping and wiring schematics to send out with quotations, through to installation guidance drawings. TOPAIRE SALES & SERVICES SDN BHD TOPAIRE EHD No.A7-22, Block A, Megan Salak Park, Jalan 2/1256, CURLS Taman Desa Petaling, $7100. Kuala Lumpur. West Malayse T:03-9056 3228 | F:03-9056 2800 | E:tass@topaire.com.my reed Sy tm. as Website: www.topaire.com.my

Vous aimerez peut-être aussi