Vous êtes sur la page 1sur 2

AM 10 KW KEP/AM-10

Configuration
8x1.5KW(Am-10), 12x2.5KW(Am-25), 24x2.5KW(Am-50)Power Amplifier/Modulator subsystem
modules (each with integral cooling fan) Main and Sandby exciter sections with Audio and RF
Drivers
Power Output
(Rated) 10Kw/25Kw/50Kw(Capable 110%)
Three preset power levels between 10% and 110% watts are selectable via LOCAL or REMOTE
Control Output level stabilized ac supply voltage veriation
RF Frequency Range
531 kHz to 1620 kHz, prefitted to one frequency as ordered
RF Terminating Impedance
50 ohm unbalanced, 1-5/8, 3-1/8 inch EIA O/P Flange
Type of Modulator
Pulsa Duration Modulator
Audio Frequency Response
0.5 dB, dc -10,000 Hz
Audio input iow pass filter selectable between Butterworth and Bessel response
Square Wave Overshoot
2% at 400 Hz (typical with Bessel filter active)
Square Wave Tilt
3% or less at 40 Hz
Audio Harmonic Distortion
Better than 1% (THD) at 95% modulation 30-10,000 Hz,
(Reduced antenna bandwidth may degrade specification)
Audio Intermodulation
1% or less at 10 kW 60/7000 Hz 4:1 ratio
Distortion
SMPTE Standards at 85% modulation
AM Stereo (RF Phase Shift)
Incidental Quadrature Modulation(IQM)36 dB or better (40 dB typical) below 95% modulation 3010,000 Hz
Modulation Capability
125% positive peak modulation capability
Carrier Shift
Not exceeding 1%
RF Harmonics
70 dB or more below 100% output
Squrious Outputs
70 dB or more below 100% output
Noise and Hum (Unweighted)
60 dB or more below 100% modulation at 100% output
Frequency (Stability)
5 Hz or 5 ppm whitchever is greater over temperature range
Audio Input
600 ohms active balanced +10 dBm nominal
Adjustable 0 to +12 dBm for 100% modulation

Power Input

198-242V 50/60 Hz three-phase 3 or 4 wire


Other voltages available
385-465V 50/60 Hz three-phase 3 or 4 wire
Permissible Power
5% voltage 5% frequency
Supply Variation
Power Consumption
13.8kW at 10kW, 0% modulation
20.1kW at 10kW, 100% continuous sine wave modulation
Power Factor
Better than 75%
Metering
Forword Output Power
Reflected Output Power
DC Input Current and Voltage to Power Blocks
DC Current Meter, each 1.25 kW Power Amplifier/Modulator Subsystem
Remote Control
Transmitter ON/OFF
Selection of Exciter A or B
Power Level selection 1 , 2 , 3
Power Trim
Alam Reset
Remote Monitoring
Forward Power Output
Reflected Power Output
Status of Critical Parameters
Ambient Temperature
-10 to 50E (derate 3E per 500m/2 per 1000 ft. above sea level)
Humidity Range
0 - 95%
Altitude
0 - 4,000m (0 - 13,000 ft.)

Vous aimerez peut-être aussi