STANDART OPERATION PROCEDURE

FOR STARTING 2X MAIN ENGINE


1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.

CHECK OIL LEVEL.


CHECK WATER LEVEL.
SWITCH ON BATTERY/ACCU.
SWITCH ON POWER SUPPLY (CONVERTER) 24VDC.
SWITCH ON POWER TO MAIN AC OR MAIN DC AT PANEL BOX ON TOP.
SWITCH ON READING COUNTER PANEL CUMMINS, THEN SELECT POSITION ON
LOCAL CONTROL.
START PRIMING OIL PUMP BEFORE YOUR START THE ENGINE (MORELESS 3-5
SECOND).
START / CRANK THE ENGINE UNTIL RUNNING.
AFTER RUNNING, PLEASE SPRAY OUT THE FUEL ON TOP SIDE THE ENGINE,
DUE TO RELEASE AIR TRAP IN BUSH PUMP TO INJECTOR.
AFTER ENGINE RUNNING, CHECK COOLING SEA WATER OVERBOARD .
AFTER THAT, AT COUNTER PANEL CUMMINS SELECT POSITION REMOTE
CONTROL , HAND OVER TO BRIDGE.

STANDART OPERATION PROCEDURE


FOR GENERATOR PORTSIDE
1.
2.
3.
4.
5.
6.
7.

CHECK OIL LEVEL.


CHECK WATER LEVEL.
SWITCH ON BATTERY/ACCU.
START THE ENGINE AT COUNTER DISPLAY (PRESS AND HOLD).
AFTER ENGINE RUNNING, CHECK COOLING SEA WATER OVERBOARD.
ENGINE RUNNING AT 1500 RPM, 380VOLT, 50 HZ.
MAIN BREAKER ALREADY TO OPERATE AT MAIN SWITCH BOARD (CHARGED
POSITION).

STANDART OPERATION PROCEDURE


FOR GENERATOR STBD
1.
2.
3.
4.
5.
6.
7.
8.
9.

CHECK OIL LEVEL.


CHECK WATER LEVEL.
SWITCH ON BATTERY/ACCU.
SWITCH ON READING COUNTER PANEL.
PRESS AND HOLD TO DIAGNOSTIC THE FAULT SYSTEM CLEAR FROM ALARM.
START THE ENGINE (PRESS AND HOLD) AT COUNTER PANEL.
AFTER ENGINE RUNNING, CHECK COOLING SEA WATER OVERBOARD.
ENGINE RUNNING AT 1500 RPM, 380VOLT, 50HZ
MAIN BREAKER ALREADY TO OPERATE AT MAIN SWITCH BOARD (CHARGED
POSITION)

STANDART OPERATION PROCEDURE


FOR FIFI ENGINE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.

CHECK OIL LEVEL THE ENGINE


CHECK WATER LEVEL THE FW COOLING SYSTEM
CHECK AND PUMP THE FUEL WITH HAND PUMP.
CLOSE THE SUCTION VALVE AT STRAINER.
SWITCH ON BATTERY/ACCU.
SWITCH ON THE PANEL, AND WAIT UNTIL 15 SECOND TO DIAGNOSTIC THE
FAULT.
START THE ENGINE AT COUNTER DISPLAY (TURN TO RIGHT).
AFTER ENGINE RUNNING, CHECK COOLING SEA WATER OVERBOARD.
ENGINE RUNNING IDLE AT 600 RPM.
FIFI ALREADY OPERATE, ENGINEER ONLY OPEN THE SUCTION VALVE AT
STRAINER AND RAISE THE SPEED/RPM ON BRIDGE TO SPRAY THE WATER.

STANDART OPERATION PROCEDURE


FOR STEERING SYSTEM
1.
2.
3.
4.

CHECK OIL HYD LEVEL AT BOW THRUSTER ROOM.


PUT THE SWITCH AT LOCAL CONTROL, THEN SWITCH ON
CHECK THE GAUGE PRESSURE OIL HYDRAULIC
IF NORMAL, SWITCH POSITION TO REMOTE CONTROL DUE TO CAN OPERATE
FROM BRIDGE
5. SWITCH ON FROM BRIDGE, THEN SWITCH ON THE MOTOR PUMP.
6. STEERING LEVER ALREADY TO OPERATED AND SWING TO LEFT AND RIGHT
TO TEST.

STANDART OPERATION PROCEDURE


FOR BOW THRUSTER
1.
2.
3.
4.
5.

RUNNING GENERATOR, CHECK VOLTAGE AT 380V AND 50 HZ.


SWITCH ON BREAKER AT PANEL BT IN ECR (INSIDE).
SELECT POSITION TO REMOTE CONTROL.
THEN GO TO BRIDGE, SWITCH ON INVERTER, THEN SWITCH ON MOTOR.
BOW THRUSTER ALREADY TO OPERATE AND SWING TO LEFT AND RIGHT TO
TEST (DOING SMOOTHLY)
6. IF ONLY 1 GENERATOR RUNNING CANNOT TO PUSH UNTIL 100%, Max 60%