Vous êtes sur la page 1sur 21

SIPS SCREWS WITH MINIMUM 1" PENETRATION

IN WOOD MEMBER IN SIP WALL PANEL


CONNECTED TO @ 24" O.C. MAXIMUM

OUTSIDE
SKIN
CONTINUOUS SEALANT
EACH SIDE OF FRAMING TYP.
AS RECOMMENDED
BY MANUFACTURER

FOAM
CORE

DRYWALL
CONTINUOUS SEALANT
AS RECOMMENDED BY MANUFACTURER
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER

8d COMMON NAILS
@ 6" O.C. EACH SIDE

WALL-TO-WALL PANEL CONNECTIONS


CORNER WALL CONNECTION

Fig. 2

DRYWALL
SUBFLOOR OR COMBINED SUBFLOOR
AND UNDERLAYMENT

SIP WALL
DRAINED AND
VENTILATED
CLADDING

FLOOR JOIST

FIELD INSTALLED
PANEL BOTTOM
PLATE
16d NAILS INTO SILL
PLATE @ 16" O.C.

8d COMMON
NAILS @ 6" O.C.
BOTH SIDES

TREATED
SILL PLATE
BE SURE OUTSIDE
SKIN IS SUPPORTED
BY SILL PLATE

SILL SEALER

CONCRETE
OR MASONRY
FOUNDATION
WALL

CONTINUOUS SEALANT EACH SIDE OF


FRAMING TYP. AS RECOMMENDED BY
MANUFACTURER

TERMITE SHIELD

MINIMUM 1/2" (13MM) DIAMETER


ANCHOR BOLTS @ 6 FEET O.C.
MAXIMUM

FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL A

Fig. 3

SIP WALL
DRAINED AND
VENTILATED
CLADDING

DRYWALL
CONTINUOUS SEALANT EACH SIDE OF FRAMING
TYP. AS RECOMMENDED BY MANUFACTURER

8d COMMON
NAILS @ 6"
O.C. EACH SIDE
CAPILLARY BREAK,
MIN. 6 MIL POLY OR
MIN. 3/4" PRESSURETREATED PLYWOOD
UNDER SILL PLATE
AND BOTH FACES

FIELD INSTALLED
TREATED BOTTOM
PLATE
MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS
@ 6 FEET O.C. MAXIMUM

TERMITE SHIELD

CONCRETE OR
MASONRY
FOUNDATION
WALL

FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL B

Fig. 4

SIP WALL
DRAINED AND
VENTILATED
CLADDING

DRYWALL
FIELD INSTALLED
TREATED BOTTOM
PLATE
8d COMMON
NAILS @ 6"
O.C. EACH SIDE

SUBFLOOR OR COMBINED SUBFLOOR


AND UNDERLAYMENT, TYP.
FLOOR JOIST

16d NAILS INTO FLOOR


JOIST PLATE @ 16" O.C.
WHEN USED AS BRACING
(3) 16d @ 16 O.C.

CONTINUOUS SEALANT
AT EACH SIDE OF
FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER
USE NAILS PER
MANUFACTURERS
RECOMMENDATIONS
FOR SIZE AND
SPACING

TREATED
SILL PLATE
CAPILLARY BREAK, MIN.
6 MIL POLY OR MIN.
3/4" PRESSURE-TREATED PLYWOOD
UNDER SILL PLATE AND BOTH FACES

CONCRETE
OR MASONRY
FOUNDATION WALL
ANCHOR BOLT AS
REQUIRED BY CODE

FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL C

Fig. 5

FINISH ROOFING MATERIAL


ROOFING FELT
8d COMMON
NAILS @ 6"
O.C. BOTH SIDES

FOAM RIDGE CAP


SIP ROOF
PANEL

CONTINUOUS SEALANT
EACH SIDE OF FRAMING
AND BOTH FACES
AS RECOMMENDED
BY MANUFACTURER

SEALANT AS
RECOMMENDED BY
MANUFACTURER
SIPS SCREWS WITH 1"
MIN. PENETRATION INTO
STRUCTURAL SUPPORT
@ 24" O.C. MINIMUM
SIP TAPE AT
RIDGE REQUIRED
DRYWALL
CONTINUOUS FIELD
INSTALLED WOOD
RIDGE SUPPORT
BEAM SHOWN

STRUCTURAL SUPPORT MEMBER WITH


MIN. 1-1/2" BEARING FOR EACH SIDE OF
PANELS

ROOF-TO-ROOF PANEL CONNECTIONS


FOAM RIDGE CAP DETAIL

Fig. 6

MINIMUM 3/8" GAP


FOR SEALANT AS
RECOMMENDED BY
MANUFACTURER

FINISHED
ROOFING
MATERIAL

BLOCKING AS REQUIRED
BY STRUCTURAL CONDITIONS

ROOFING
FELT

SIPS SCREWS W/ MINIMUM 1"


PENETRATION INTO
STRUCTURAL SUPPORT
@ 24" O.C. MINIMUM

SIP TAPE AT
RIDGE REQUIRED

RIDGE SUPPORT
BEAM

ROOF-TO-ROOF PANEL CONNECTIONS


BEVELED SIP RIDGE DETAIL

Fig. 7

PANEL SCREW
FINISHED
ROOFING
MATERIAL
ROOFING
FELT
SIP ROOF
PANEL

8d COMMON NAILS
@ 6" O.C. EACH SIDE

CONTINUOUS
SEALANT EACH
SIDE OF FRAMING
AS RECOMMENDED
BY MANUFACTURER,
AND ROOF PANEL
2x JOINT

DRYWALL

TOP PLATE
SIP WALL PANEL
DRAINED AND
VENTILATED
CLADDING

ROOF-TO-WALL PANEL CONNECTIONS


BEVELED SIP WALL

Fig. 8

WEDGE INFILL PIECE


PANEL SCREW
FINISHED
ROOFING
MATERIAL
ROOFING
FELT
CONTINUOUS SEALANT EACH SIDE
OF FRAMING AS RECOMMENDED BY
MANUFACTURER

SIP ROOF
PANEL
CONTINUOUS
SEALANT EACH
SIDE OF FRAMING,
AND ROOF PANEL
2x JOINT

8d COMMON NAILS
@ 6" O.C. BOTH SIDES

TOP PLATE

DRYWALL
CONTINUOUS SEALANT EACH SIDE
OF FRAMING AS RECOMMENDED BY
MANUFACTURER

SIP WALL PANEL


DRAINED AND
VENTILATED
CLADDING

ROOF-TO-WALL PANEL CONNECTIONS


WEDGE INFILL PIECE

Fig. 10

8d COMMON NAILS
6" O.C. BOTH SIDES

CONTINUOUS SEALANT TYPICAL


AS RECOMMENDED BY
MANUFACTURER

CONTINUOUS SEALANT BOTH SIDES


TYP. OF FRAMING AS RECOMMENDED
BY MANUFACTURER
16d COMMON NAILS
@ 16" O.C.

FINISHED ROOFING
MATERIAL
ROOFING
FELT

SIP TAPE AT
RIDGE REQUIRED

ROOF-TO-ROOF PANEL CONNECTIONS


RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG)

Fig. 11

SECOND FLOOR
DRYWALL

SIP WALL
PANEL

STANDARD WIRE CHASE


16d COMMON NAILS @ 16" O.C.
WHEN USED AS BRACING (3) 16d
COMMON NAILS @ 16" O.C.

DRAINED AND
VENTILATED
CLADDING

CONTINUOUS SEALANT EACH SIDE OF


FRAMING TYP. AS RECOMMENDED BY
MANUFACTURER

2x BOTTOM
PLATE

3/4" T&G FLOOR SHEATHING


(GLUED & NAILED) TO EXTEND
OVER TOP OF SIP WALL

8d COMMON
NAILS @ 6"
O.C. BOTH SIDES

FLOOR JOISTS

METAL STRAP
AS REQUIRED
OR LTP4
SIMPSON CLIP
CAP PLATE
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED BY
MANUFACTURER
TOP FLANGE METAL FLOOR JOIST
HANGAR (BY OTHERS)

DRYWALL

FIRST FLOOR

2ND FLOOR CONNECTION DETAILS


HANGING FLOOR

Fig. 12

SECOND FLOOR
DRYWALL

SIP WALL
PANEL

STANDARD WIRE CHASE


16d COMMON NAILS @ 16" O.C.
WHEN USED AS BRACING (3) 16d
COMMON NAILS @ 16" O.C.

DRAINED AND
VENTILATED
CLADDING

2x BOTTOM
PLATE

INSULATION
3/4" T&G FLOOR SHEATHING
(GLUED & NAILED) TO EXTEND
OVER TOP OF SIP WALL

8d COMMON
NAILS @ 6" O.C.
BOTH SIDES

FLOOR JOISTS (I-JOIST SHOWN)

METAL LATERAL
TIE PLATE NAILED
TO BOTTOM OR
SHIM PLATES AND
RIM BOARD
RIM BOARD
METAL LATERAL
TIE PLATE NAILED
TO BOTTOM OR
SHIM PLATES AND
RIM BOARD

FIRST FLOOR
CONTINUOUS SEALANT EACH SIDE OF
FRAMING TYP. AS RECOMMENDED BY
MANUFACTURER

8d COMMON
NAILS @ 6" O.C.
BOTH SIDES

CAP PLATE AS REQUIRED


BY MANUFACTURER
DRYWALL
CONTINUOUS SEALANT EACH SIDE
OF FRAMING TYP. AS RECOMMENDED
BY MANUFACTURER

2ND FLOOR CONNECTION DETAILS


RIM BOARD

Fig. 13

ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA.
CONTINUOUS
SEALANT EACH SIDE
OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER

CONTINUOUS SEALANT AS
RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL
CONNECTION DETAIL
SHOWN ELSEWHERE

DRIP
EDGE
FLASHING
FASCIA

SOFFIT BOARD

EAVES DETAILING
EAVES DETAIL A

Fig. 14

ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER

DRIP EDGE
FLASHING

CONTINUOUS SEALANT AS
RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL CONNECTION
DETAIL SHOWN ELSEWHERE

2X BLOCKING
TO SUPPORT
FASCIA BOARD

8d COMMON NAILS
@ 6" O.C. BOTH SIDES

2x FRAMING MEMBER

FASCIA

SIP SCREW
SOFFIT BOARD

EAVES DETAILING
EAVES DETAIL B

Fig. 15

ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA.
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP.
RECOMMENDED BY
DRIP EDGE

ING
AM
R
F
2x

ER
MB
ME

2x FRAMING MEMBER

USE NAILS PER MANUFACTURER'S


RECOMMENDATIONS FOR SIZE AND
SPACING.

CONTINUOUS SEALANT
RECOMMENDED BY
MANUFACTURER
8d COMMON NAILS
@ 6" O.C. BOTH SIDES

FASCIA

SOFFIT BOARD

SIP SCREW

EAVES DETAILING
EAVES DETAIL C

Fig. 16

ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER

DRIP EDGE
FLASHING
8d COMMON NAILS
@ 6" O.C. BOTH
SIDES
CONTINUOUS SEALANT
AS RECOMMENDED BY
MANUFACTURER

BEVELED
BLOCKING
TO SUPPORT
FASCIA BOARD

ROOF-TO-WALL PANEL
CONNECTION DETAIL
SHOWN ELSEWHERE

FASCIA
SOFFIT BOARD

USE NAILS PER MANUFACTURER'S


RECOMMENDATIONS FOR SIZE AND
SPACING.

EAVES DETAILING
EAVES DETAIL D

Fig. 17

ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP. AS
RECOMMENDED BY
DRIP EDGE

8d COMMON NAILS @
6" O.C. BOTH SIDES
CONTINUOUS SEALANT
AS RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL CONNECTION
DETAIL SHOWN ELSEWHERE
USE NAILS PER MANUFACTURER'S
RECOMMENDATIONS FOR SIZE AND
SPACING.
FASCIA
SOFFIT BOARD

EAVES DETAILING
EAVES DETAIL E

Fig. 18

CONTINUOUS SEALANT EACH


SIDE OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER
SIP PANEL

EXPANSION GAP 1/8"

SEALANT AS RECOMMENDED
BY MANUFACTURER

8d COMMON NAILS
@ 6" O.C. EACH STRIP
AND EACH SIDE

CHASE FOR EXPANDED


FOAM SEALANT

WALL-TO-WALL VERTICAL PANEL CONNECTIONS


SURFACE SPLINE FOR VERTICAL SPLICE

Fig. 19

2x FRAMING AROUND
WINDOWS AND DOOR OPENINGS

DOOR AND WINDOW FRAMING

Fig. 21

(2) ROWS 16d COMMON


NAILS@ 16" O.C. MINIMUM
SIP PANEL

EXPANSION GAP 1/8"

8d COMMON NAILS
@ 6" O.C. EACH PANEL
AND EACH SIDE

CONTINUOUS SEALANT EACH


SIDE OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER

WALL-TO-WALL VERTICAL PANEL CONNECTIONS


DIMENSIONAL LUMBER SPLINE

Fig. 20

CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER

VALLEY
FLASHING

DOUBLE 2x SPLINE
BEVEL CUT

SIP ROOF PANEL


16d COMMON
NAILS @ 16"
O.C. MINIMUM
8d COMMON NAILS @
6" O.C. EACH PANEL
AND EACH SIDE
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS
RECOMMENDED BY
MANUFACTURER AT
SUPPORT MEMBERS

SIPS SCREW
W/ MINIMUM 1"
PENETRATION
INTO STRUCTURAL
SUPPORT
STRUCTURAL SUPPORT

DRYWALL

ROOF-TO-ROOF PANEL CONNECTIONS


VALLEY DETAIL

Fig. 22

SIP TAPE

SIP PANEL

8d COMMON NAILS
@ 6" O.C. EACH PANEL
AND EACH SIDE

EXPANSION GAP 1/8"

CONTINUOUS SEALANT
EACH SIDE OF FRAMING TYP.
AS RECOMMENDED BY
MANUFACTURER
BLOCK SPLINE

WALL-TO-WALL VERTICAL PANEL CONNECTIONS


BLOCK SPLINE

Fig. 23