Académique Documents
Professionnel Documents
Culture Documents
CENTRIFUGAL COMPRESSOR
JONGSIK OH
1
EULER EQUATION
C2 U 2 = r2 ω
Cm 2 Torque T = m
& (Cθ 2r2 − Cθ1r1 )
Cθ2 Power P = Tω
=m& (U 2Cθ 2 − U1Cθ1 )
W2
W1
C1
C m1
U 1 = r1 ω
C θ1
RELAVANT UNIT
Torque T = m
& (Cθ 2r2 − Cθ1r1 )
Unit : N.m
Power P = Tω
=m& (U 2Cθ 2 − U1Cθ1 )
Unit : Watt
2
PREWHIRL OR PREROTATION
W1
C m1
C θ1
C1 α 1 U = r ω
1 1
C 1 = C m 1 , C θ1 = 0
PART-LOAD CONTROL
3
SLIP FACTOR
W2
W2b
C2
β 2b
b
β2
α 2α 2b C m 2
Cθ2 C θ 2b
W1
U 2 = r2 ω
Cθ 2
r2 ζ≡
Cθ 2b
U 1 = r1 ω
r1
JongSik Oh Turbomachinery Basics
ojsturbo@
ojsturbo@korea.com
korea.com Centrifugal Compressors
4
EFFICIENCY
Isentropic Work
Isentropic Efficiency ηC ≡
Re al Work
h 2' − h1
=
h 2 − h1
T2' − T1
= for ideal gases
T2 − T1
γ −1
p2 γ
− 1
p
= 1 for ideal gases
T2
−1
T1
γ −1
p2 γ
− 1
p
= 1 γ −1 for ideal gases where ηP is the polytropic efficiency
p 2 γηp
p − 1
Independent of overall pressure ratios
1
JongSik Oh Turbomachinery Basics
ojsturbo@
ojsturbo@korea.com
korea.com Centrifugal Compressors
5
ENERGY TRANSFER
0 2
SPECIFIC SPEED
Machine Operation Parameter
6
JongSik Oh Turbomachinery Basics
ojsturbo@
ojsturbo@korea.com
korea.com Centrifugal Compressors
7
NQ 1 / 2
NS =
(gH ) 3 / 4
where N : rad/s, Q : m 3 /s, H :m (Balje)
VANED DIFFUSER
8
VANED DIFFUSER
9
AXIAL VANED DIFFUSER
VOLUTE/SCROLL
10
PERFORMANCE MAP
PERFORMANCE MAP
11
CORRECTED CONDITIONS
Dimensional Analysis
N
N CORRECTED ≡
TO1 & , p O , RTO ) = 0
f(D, N, m
288.15
p T m & RTO1 ND
f O 2 , O2 , , =0
p O1 TO1 D 2p O1 RT
O1
p O1
101325
m
& TO1 m& 288.15
= CORRECTED
p O1 101325
where N(rpm), m
& (kg/s), T(K), p(Pa) N N
= CORRECTED
TO1 288.15
IMPELLER INCIDENCE
surge choke
12
DIFFUSER INCIDENCE
SPLITTER BLADES
13
SPLITTER BLADES
14
SOME ANGLES
IMPELLER CFD
15