Académique Documents
Professionnel Documents
Culture Documents
SSC-APB005-EN
TOPIC:
Coil airside pressure drop versus airflow for 4FX style furnace coils.
Wet coil pressure drop characteristics for cooling coils
Airside pressure drop in inches water column ("wg) versus airflow in cubic feet per minute (CFM)
PRESSURE DROP
Model
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
4FX*(A,B,C)024AC3
310
530
740
930
1110
1280
1450
1610
4FX*(B,C,D)036AC3
510
860
1160
1440
1710
1960
2200
2430
4FX*(B,C,D)042AC3
360
570
750
910
1060
1200
1340
1460
4FX*(B,C,D)048AC3
410
680
920
1130
1330
1520
1700
1880
4FX*(B,C,D)060AC3
570
940
1270
1570
1840
2110
2360
2600
4FX*(B,C,D)061AC3
390
650
880
1080
1280
1460
1630
1800
4FXCH024AC3CHA
290
470
620
760
890
1020
1130
1250
4FXCH036AC3CHA
310
520
700
860
1020
1160
1300
1430
4FXCH048AC3CHA
510
850
1150
1410
1670
1900
2130
2350
4FXCH060AC3CHA
550
900
1190
1460
1710
1940
2160
2370
4FXFH024AC3CHA
390
630
830
1020
1190
1350
1500
1640
4FXFH036AC3CHA
740
1170
1540
1860
2160
2430
2690
2940
4FXFH060AC3CHA
610
970
1270
1540
1790
2020
2240
2450
* = C or A
C = Cased Coil