Vous êtes sur la page 1sur 2

Item

ERP
Total Power Per Cell
Channel Power Offset
Total Available Bandwidth
Sub-carrier spacing
Bandwidth for Maximum Power
Number of Resource Blocks (RBs)
Power per Sub-carrier
Cell associated losses (cable, connector, combiner)
Transmit Antenna Gain
Per Sub-carrier EIRP
UE Sensitivity and MAPL at UE
Thermal Noise
Receiver Noise Figure
Noise Floor
Required SNR
Sensitivity
Estimated SNR
Geometry (Iof/Ioc) @ Full Load
Load Percentage
Other-to-Same Cell interference (Ioo/Ioc), considering loading
MAPL at the UE
Propagation and RX Gain and Losses
Receive Antenna Gain
UE Associated Losses (cable+connectors+combiner)
Receive Gain and Losses
Cell Edge Reliability
Log-Normal Fading Standard Deviation
Mean Building Penetration Losses
Building Penetration Loss St. Dev.
Body Loss
Combined St. Dev.
BPL and Log Normal Fading
Final Path Loss to cell border

Formulation

ERP
A = input
B = input
C = input
D = input
E = 10*Log10(C*10^6)
F = input from mapping table
G = A + 10*Log10((D*10^3)/(C*10^6)) + B
H = input
I = input
J=G+H+I
UE Sensitivity and MAPL at UE
K = 10*Log10(290*1.38*10^-23)*10^3)
L = input
M = K + 10*Log10(D*10^3) + L
O = input
S=M+O

P = input
Q = input
N = P^-1
see training material
pagation and RX Gain and Losses
U = input
V = input
W = input
X = input
Y = input
A' = input
Y' = input
B' = input
Y" = sqrt (Y^2 + Y'^2)
Z = -NORMINV(X,B'+A', Y")
D' = J - S + W + Z

Values

Unit

43 dBm
0 dBm
10 MHz
15 KHz
70 dB-Hz
50 N/A
14.76 dBm
-3 dB
17 dBi
28.76 dBm
-174.0 dBm/Hz
9 dB
-123.2 dBm/Hz
-3 dB
-126.2 dB
-3 dB
-2 dBm/Hz
100%
2 dB
146.44 dB
0 dBi
0 dBi
0 dBi
90%
8 dB
10 dB
8 dB
0 dB
11.31 dB
-24.50 dB
130.48 dB