Life extension of pipeline systems

- use and definition of risk marix


Stig Goplen
07 April 2010

Ageing of pipeline systems

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.

Aging of pipeline systems

PoF

Failure

10-1
10-2
10-3
10-4

E
Intervention
Repair
Modification

D
C
B

Target failure probability

A
Time

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.

Ageing of mechanical equipment

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.

Ageing of mechanical equipment

PoF

Failure

>90%

70-90% 4

Replacement
Repair

30-70% 3
10-30%

0-10%

1
Time

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.

Applicable risk matrix

PoF
10-1
10-2
10-3
10-4

>90%

70-90%

30-70%

10-30%

40

0-10%

E
D

10

15

30

10
15

30

56

CoF

CoF

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.

Mechanical systems

PoF

Pipeline system

Safeguarding life, property


and the environment
www.dnv.com

Life extension of pipeline systems


06 April 2010
Det Norske Veritas AS. All rights reserved.