Date
Revision
10/12/2008
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
INTERCONNECTION DETAILS
LENGTH
TO
SIZE
ROUTE
MTRS.
9-Gg-1-01
CHP LCSS#2
7F2
Belt conveyor-4A
3Cx300 sq mm Al
As per site
40
9-Gg-1-02
CHP LCSS#2
7F2
Belt conveyor-4A
3Cx300 sq mm Al
As per site
40
CORE
FROM
R
11F2
Belt conveyor-4B
3Cx300 sq mm Al
As per site
40
9-Gg-1-04
CHP LCSS#2
11F2
Belt conveyor-4B
3Cx300 sq mm Al
As per site
40
6F4
Flap Gate-3A
3Cx2.5 sq mm Cu
As per site
40
9-Gg-1-06
CHP LCSS#2
17F1
Flap Gate-3B
3Cx2.5 sq mm Cu
As per site
40
9-Gg-1-07
CHP LCSS#2
7F1
Belt conveyor-5A
2x3Cx120 sq mm Al
As per site
550
9-Gg-1-08
CHP LCSS#2
7F1
Belt conveyor-5A
2x3Cx120 sq mm Al
As per site
550
11F1
Belt conveyor-5B
2x3Cx120 sq mm Al
As per site
550
9-Gg-1-10
CHP LCSS#2
11F1
Belt conveyor-5B
2x3Cx120 sq mm Al
As per site
(225 x
2=550)
9-Gg-1-11
CHP LCSS#2
6R6
Belt Scale-2A
3Cx2.5 sq mm Cu
As per site
275
9-Gg-1-12
CHP LCSS#2
13R2
Belt Scale-2B
3Cx2.5 sq mm Cu
As per site
275
9-Gg-1-13
CHP LCSS#2
2F2
Flap Gate-4A
3Cx2.5 sq mm Cu
As per site
275
9-Gg-1-14
CHP LCSS#2
14R3
Flap Gate-4B
3Cx2.5 sq mm Cu
As per site
275
9-Gg-1-15
CHP LCSS#2
5R1
3Cx16 sq mm Al
As per site
210
9-Gg-1-16
CHP LCSS#2
12F1
3Cx16 sq mm Al
As per site
210
9-Gg-1-17
CHP LCSS#2
3R1
Belt Conveyor-6A
3Cx120 sq mm Al
As per site
Page 1 of 4
350
MOTOR SPACE
HEATER
TREMINAL
32
R
1450-08
1450-08
1450-08
1450-08-44
1450-08-44
1450-0813A
1450-0813A
1450-0813A
1450-0813A
MOTOR SPACE
HEATER
TREMINAL
32
1450-08
31
MOTOR SPACE
HEATER
TREMINAL
32
31
2
CHP LCSS#2
31
9-Gg-1-09
2
CHP LCSS#2
MOTOR SPACE
HEATER
TREMINAL
32
9-Gg-1-05
DRG. NO.
31
2
CHP LCSS#2
APPLICATION
TO
9-Gg-1-03
CHP LCSS #2 LV
SWGR.-LV Power
3VYN492201-6
1450-08
1450-08-33
1450-08-44
1450-08-44
1450-08-46
1450-08-46
W
3-Phase O/G supply
1450-08
/ Remarks
Power Cables
ABB Limited
Date
Revision
10/12/2008
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
INTERCONNECTION DETAILS
CORE
FROM
1
9-Gg-1-18
CHP LCSS#2
3R1
Belt Conveyor-6A
3Cx120 sq mm Al
As per site
17R1
Belt Conveyor-6B
3Cx120 sq mm Al
As per site
350
9-Gg-1-20
CHP LCSS#2
17R1
Belt Conveyor-6B
3Cx120 sq mm Al
As per site
350
40
R
Tripper conveyor-1A
3Cx25 sq mm Al
As per site
250
9-Gg-1-22
CHP LCSS#2
6R4
Tripper conveyor-1B
3Cx25 sq mm Al
As per site
250
9-Gg-1-23
CHP LCSS#2
3F4
3Cx16 sq mm Al
As per site
40
9-Gg-1-24
CHP LCSS#2
17F3
3Cx16 sq mm Al
As per site
225
9-Gg-1-25
CHP LCSS#2
3R4
3Cx16 sq mm Al
As per site
225
9-Gg-1-26
CHP LCSS#2
2F1
3Cx2.5 sq mm Cu
As per site
175
9-Gg-1-27
CHP LCSS#2
13R1
Vibro Feeder-1
3Cx2.5 sq mm Cu
As per site
175
9-Gg-1-29
CHP LCSS#2
5F5
Sump Pump-1
3Cx2.5 sq mm Cu
As per site
175
9-Gg-1-30
CHP LCSS#2
17F2
Sump Pump-2
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-31
CHP LCSS#2
6R3
3Cx2.5 sq mm Al
As per site
110
9-Gg-1-32
CHP LCSS#2
15F3
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-33
CHP LCSS#2
4R7
Metal detector
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-34
CHP LCSS#2
17F6
Flap Gate-1
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-35
CHP LCSS#2
2R1
Primary Crusher
3Cx70 sq mm Al
As per site
100
9-Gg-1-36
CHP LCSS#2
2R1
Primary Crusher
3Cx70 sq mm Al
As per site
100
15R2
3Cx4 sq mm Al
As per site
Page 2 of 4
75
1450-08
1450-08
1450-08
1450-08-33
1450-08-33
1450-08-31
1450-08-31
1450-08-31
1450-08-43
1450-08
1450-08-11
1450-08-11
1450-08-33
1450-08
1450-08
1450-08-44
1450-08-13
1450-08-13
1450-08
MOTOR SPACE
HEATER
TREMINAL
40
39
2
CHP LCSS#2
9-Gg-1-37
MOTOR SPACE
HEATER
TREMINAL
40
R
4R3
39
CHP LCSS#2
9-Gg-1-21
MOTOR SPACE
HEATER
TREMINAL
DRG. NO.
39
2
CHP LCSS#2
APPLICATION
TO
350
9-Gg-1-19
CHP LCSS #2 LV
SWGR.-LV Power
3VYN492201-6
/ Remarks
Power Cables
ABB Limited
Date
Revision
10/12/2008
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
9-Gg-1-38
CHP LCSS#2
2F3
Flap Gate-2
3Cx25 sq mm Cu
As per site
80
9-Gg-1-39
CHP LCSS#2
14R4
3Cx2.5 sq mm Al
As per site
80
9-Gg-1-40
CHP LCSS#2
8F2
Scecondary Crusher
3Cx300 sq mm Al
As per site
100
9-Gg-1-41
CHP LCSS#2
8F2
Scecondary Crusher
3Cx300 sq mm Al
As per site
100
INTERCONNECTION DETAILS
CORE
FROM
R
Y
Y
12F4
3Cx2.5 sq mm Cu
As per site
80
9-Gg-1-43
CHP LCSS#2
6R5
3Cx2.5 sq mm Cu
As per site
80
9-Gg-1-44
CHP LCSS#2
12F3
3Cx2.5 sq mm Cu
As per site
80
9-Gg-1-45
CHP LCSS#2
5R3
3Cx16 sq mm Al
As per site
85
9-Gg-1-46
CHP LCSS#2
17F5
3Cx16 sq mm Al
As per site
100
9-Gg-1-47
CHP LCSS#2
4R6
3Cx16 sq mm Al
As per site
100
9-Gg-1-48
CHP LCSS#2
17R4
3Cx16 sq mm Al
As per site
90
9-Gg-1-49
CHP LCSS#2
5F4
3Cx16 sq mm Al
As per site
175
9-Gg-1-50
CHP LCSS#2
13R5
Pent House-Hoist
3Cx16 sq mm Al
As per site
125
9-Gg-1-51
CHP LCSS#2
17R3
UPS
3Cx25 sq mm Al
As per site
20
9-Gg-1-52
CHP LCSS#2
4R5
3Cx16 sq mm Al
As per site
25
9-Gg-1-53
CHP LCSS#2
2F4
3Cx2.5 sq mm Cu
As per site
125
9-Gg-1-54
CHP LCSS#2
17R2
3Cx2.5 sq mm Cu
As per site
125
9-Gg-1-55
CHP LCSS#2
6R1
3Cx25sq mm Al
As per site
125
9-Gg-1-56
CHP LCSS#2
12R3
3Cx25sq mm Al
As per site
100
9-Gg-1-57
CHP LCSS#2
4R4
3Cx16 sq mm Al
As per site
25
9-Gg-1-58
CHP LCSS#2
5F2
3Cx70 sq mm Al
As per site
25
9-Gg-1-59
CHP LCSS#2
15F2
Lighting Load
3Cx120 sq mm Al
As per site
15
Page 3 of 4
32
R
1450-08-44
1450-08-12
1450-0813A
1450-0813A
MOTOR SPACE
HEATER
TREMINAL
DRG. NO.
31
2
CHP LCSS#2
APPLICATION
TO
B
9-Gg-1-42
CHP LCSS #2 LV
SWGR.-LV Power
3VYN492201-6
1450-08
1450-08
1450-08-43
1450-08-31
1450-08-31
1450-08-31
1450-08-31
1450-08-31
1450-08-31
1450-08-33
1450-08-31
1450-08-11
1450-08-11
1450-08-12
1450-08-12
1450-08-31
1450-08-33
1450-08-33
/ Remarks
Power Cables
ABB Limited
Date
Revision
10/12/2008
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
9-Gg-1-60
CHP LCSS#2
14R1
3Cx300 sq mm Al
As per site
15
9-Gg-1-61
CHP LCSS#2
14R2
Dewatering pumps
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-62
CHP LCSS#2
2R2
Lighting Load
3Cx95 sq mm Al
As per site
15
9-Gg-1-63
CHP LCSS#2
6R2
UPS
3Cx25 sq mm Al
As per site
20
9-Gg-1-64
CHP LCSS#2
13F4
Dewatering pumps
3Cx2.5 sq mm Cu
As per site
100
9-Gg-1-65
CHP LCSS#2
13R3
Tripper conveyor-1A
3Cx25 sq mm Al
As per site
250
9-Gg-1-66
CHP LCSS#2
13R4
Tripper conveyor-1B
3Cx25 sq mm Al
As per site
250
9-Gg-1-67
CHP LCSS#2
17F4
3Cx16 sq mm Al
As per site
100
Page 4 of 4
CHP LCSS #2 LV
SWGR.-LV Power
3VYN492201-6
INTERCONNECTION DETAILS
CORE
FROM
R
Y
APPLICATION
TO
B
1450-08-33
1450-08-11
1450-08-31
1450-08-31
1450-08-31
1450-08-33
1450-08-31
1450-08-11
/ Remarks
Power Cables