Vous êtes sur la page 1sur 11

SHELL AND TUBE

43200 lb/hr of 350 API distillate is cooled from 250 to 120 0 F using cooling water from 85 to
120 F. Available for the service is a 19 in. ID 1-2 exchanger having 204 tubes in. OD, 16
BWG, 160long on 1-in.square pitch. Baffles are spaced 5 in. Apart, and the bundle is
arranged for four passes. What arrangement gives the more nearly balanced pressure drops,
and wahat is the dirt factor? What is the optimum outlet-water temperature? (viscosities of
the distillate are given in Prob. 7.6) the viscosity of the distillate is 3.1 centripoise at 100 0F
and 1.3 centripoise at 2100 F

Solution:
Distilate
w

T
outlet

T inlet

lb/jam
43200

T avg

250

API
o

120

c
btu/lb F
0,52
(Fig.4)

185

35

Water
w
lb/jam
83437,7

T inlet
o

F
85

T
outlet
o

F
120

T avg
o

F
102,5

c
btu/lb oF
1

Spesifikasi Heat Exchanger


Inside diameter shell
(ID)
Inside diameter tube
(ID)
Outside diameter tube
(OD)
Panjang tube (L)
BWG (British Weight
Gage)
Jarak antar tube
(C=Pt-OD)
Pitch tube (Pt)
Jumlah tube (Nt)
Jarak baffle (B)

19,25 inch
0,62 Inch (Table 10)
1 inch
16 inch
16
0,25 inch
1 inch
204
5 inch
1

Shell
Tube
Susunan tube
De

1 pass
4 pass
square
0,95 inch

1.

Heat Balance
Q distilate

= W x C x T
= 43200 lb/hr x 0,52Btu/lb. F x (250-120) F
= 2920320Btu/hr
2920320

W water =

Btu
hr

Btu
x ( 12085 ) o F
lbo F

= 83437,7 lb/hr
Q water = W x C x T
= 83437,7 lb/hr x 1Btu/lb. F x (120-85) F
= 2920320Btu/hr

2.

Log Mean Temperature Difference (LMTD)


Hot
Fluid
250
120
130

LMTD=

LMTD=

Higher
T
Lower T
Dif

Cold
Fluid

120
85
35

130
35
95

t2
t1
t2 - t1

t 2 F+ t 1 F
t 2 F
ln
t1 F

130 F+ 35 F
130 F
ln
35 F

LMTD= 72,479

R=

T 1T 2 250120
=
= 3,714
t 2t 1
12085
3

S=

t 2t 1 12085
=
= 0,2121
T 1t 1 25085

Karena tipe heat exchanger 1 shell 4 pass or more, maka dari harga R = 3,714 dan
S=0,2121 dapat diperoleh harga Ft = 0,85 (Fig.18)
LMTD = LMTD x Ft = 72,479 x 0,85 = 79,98468F

3. Temperatur Kalorik
tc = T2 t1 = 120 85 = 35 F
th = T1 t2 = 250 120= 130 F
tc T 2t 1 35 F
=
=
=0,269
th T 1t 2 130 F
Untuk API 35 dan T1 T2 = 130 F, maka diperoleh harga Kc(mean) = 0,28. Dari harga
tc
=0,269
diperoleh harga Fc = 0,374 (Fig. 17)
th
Temperatur Kalorik Distilate
Tc = T2 + Fc th
= 120F + 0,374 .130 F
= 168,62F
Temperatur Kalorik Water
tc = t1 + Fc tc
= 85 F + 0,374 .35F
= 98,09F

Shell Side (Vac. Bottom)

Area
=

Tube Side (Vac.Column Feed)


Flow Area
at

ID x C' x B

Nt x a't
at (table

144 x Pt

144 x n

10)

19,25inchx 0,25inchx 5inch


in 2
144 2 x1inch
ft
=

0,1671006
9ft2

Mass Velocity
Gt
=

Velocity
= W
as

ft2

W
at

lb
jam
0,10695 ft 2

lb
jam
0,1671 ft 2
=

=
258526,75
3 lb/jam ft2

old's Number

DexGs
1,97
v
isc
4,7674

780095

lb/jam ft2

Reynold's Number
De (Fig.
28)

0,106958

83437

43200

204 x 0,302inch 2
in 2
144 2 x 4
ft

cp
lb/ft jam

Re

visc

=
=

IDxGt
0,75
visc
1,815

cp
(Fig. 14)
lb/ft jam

Tube dengan OD 3/4 inc dan BWG 16


ID tube
=
0,62 inc (Table 10)
=
0,051667 ft
=

0,95 inc
0,079167 ft
4293,05

Re t

22206,57

lb
jam
3600

Gt

r Perpindahan Panas (jH)


=
34 (Fig. 28)

=
=

ien Perpindahan Panas


=
168,62 oF
=
35
btu/(jam)(ft2)(F/ft)
=
0,076 (Fig.1)
=
0,52 btu/lb oF (Fig.4)
=
0,0791667 ft
=

3,467

Koefisien Perpindahan Panas


hi
=
900 x Qs

(Fig. 25)

4,7674 lb/ft jam

ks cp .s 3
jH
(
) Qs
De
ks
1

3
btu
btu
lb
0,076
0,52
x 4,7674
2 o
o
( jam)( ft )( F )
(lb)( F )
( ft )( jam)
34 x
xQs
btu
0,0791667 ft
0,076
( jam)( ft 2 )( o F )

104,289

btu
( jam)( ft 2 )( o F )

hi
t

900

btu
( jam)( ft 2 )( o F )

hio
hi
ID

x
Qt
Qt OD
6

hio
t

744

btu
( jam)( ft 2 )( o F )

erature dinding tube (tw)

ho
Qs
tc
.(Tc tc)
hio ho

Qt Qs

104,28
98,09o F

btu
( jam)( ft 2 )( o F )

btu
btu
744
104,28
2 o
( jam)( ft )( F )
( jam)( ft 2 )( o F )

106,76

viskositas fluida luar dan dalam

4,7674
7,26

Qt
0,9428

ien Perpindahan Panas Terkoreksi


=

Rasio viskositas fluida luar dan dalam

0,14

=
=

.(168,62 98,09)O F

ho
Qs
Qs

98,326

btu
( jam)( ft 2 )( o F )

0 ,14

1,815
1,694( Fig .14)

1,0097

Koefisien Perpindahan Panas Terkoreksi


hio
=

hio
Qt
Qt

751,22

btu
( jam)( ft 2 )( o F )

13. Coefficient Clean Overall (Uc)


Coefficient Clean Overall adalah koefisien perpindahan panas heat exchanger dalam
keadaan bersih.
Btu
Btu
x 98,326
2
2
hio x ho
hr . ft .
hr . ft .
U c=
=
hio+ho
Btu
Btu
751,22
+98,326
2
hr . ft .
hr . ft 2 .
751,22

86,945

Btu
hr . ft 2 .

14. Coefficient Dirt Overall (Ud)


Ud=

Q
A . LMTD . F T
Dimana :
A

= Nt x L x as (Table 10)
= 204 buah x 16 x 0,1963 ft2/ft
= 640,7232 ft2

Nilai as diperoleh dari Tabel 10 yaitu dengan OD = 1 in dan BWG 14 diperoleh surface
in outside = 0,218 ft2/ft.

Ud=

Q
2920320 Btu /hr
=
A . LMTD . F T 640,7232 ft 2 x 61,607
73,98

Btu
hr . ft 2 .

15. Fouling factor (Rd)


Rd=

UcUd
Uc x Ud

Btu
Btu
73,98
2
2
hr . ft .
hr . ft .
Rd=
Btu
Btu
86,94
x 73,98
2
hr . ft .
hr . ft 2 .
86,94

0,002

16. Pressure Drop (P)


1. Tube Side
a. Berdasarkan panjang pipa
2

Pt =

f x Gt x L x n
10
5,22 x 10 x D x Sg x t

psi

Untuk Ret = 22206,57 diperoleh harga f = 0,00021 (Fig. 26)


lb
x 16 ft x 4
jam . ft 2

3,003 psi
0,00021 x
Pt =

780095,49

b. Berdasarkan tube passes


2

4xn V p
Pr =
x
Sg 2 g 144

Dengan Gt = 780095,49 maka

Pr =

V2 p
2 g 144

(Fig. 27)

adalah 0,08

4x4
x 0,08=1,28 psi
1

Maka P total untuk tube side

= Pt + Pr
= 3,003 + 1,28
= 4,283psi

2. Shell Side

f x G2s x Ds x ( N +1)
Ps =
psi
5,22 x 1010 x De x Sg (Fig . 6) x s
Untuk Res = 4293,05, f = 0,0024
Ps=

0,0024 x 258526,75322 lb / jam . ft 2 x 1,604 ft x 38,4


=3,11 psi
10
5,22 x 10 x 0,079 ft x 0,815 x 0,9428

Optimum Outlet
250x= t 2
12085=t 1=35
Asumme
Q=U A Lmtd

U=

Q
A Lmtd

Btu
hr
Btu
U=
=62,885
2
2
640,7232 ft .72,479
hr . ft .
2920320

=8000 operating hours annualy


C w=

$ 0,01
0,01 dollar
=
1000 gal 8300 lb

20 Repair maintenance10
At unit cost of $4 per square foot the annual fixed charge is
$ 4 . 0, 3=$ 1, 20

The spesific heat of water is taken as 1

10

U C w 62,885 . 8000 0,01


=
=0, 505
CF C
1,2 .1
8300

T 1T 2 250120 130
=
=
=3,71
t 1
12085
35
t2
=3
t1
t 2=T 1t 2 =3 .35=105
t=250105=14 5

11

Vous aimerez peut-être aussi