Vous êtes sur la page 1sur 6

A23.

3-04 Precast Corbel Design Spreadsheet

Jan 2008

(2/3 Avf + An)

Design Information
fc' =
fy =
Vf =
Nf =

35
400
1000
200

Mpa
Mpa
kN
kN

Lp =
a=
h=
d=
b=
Lc =
c=

300
165
600
545
600
600
50

mm
mm
mm
mm
mm
mm
mm

fc =
ag =

0.70
20

a/d =

0.303

(e = 100 mm)-min.
Lp
(Always use Gr 400W)
(Min. 0.2 Vf, Max. 1.0 Vf)
(Corbel Projection)
(Typ. 0.75 Lp)
(Overall Corbel Height)
(Corbel Width)
(Column Depth)
(Cover to back of As bars)
(0.70 for CPCI Certified Plant))

mm

(Aggregate size, mm)

Lc

(Should be < 1.0)

c
fy

Page 1 of 3

A23.3-04 Precast Corbel Design Spreadsheet

vr,max =

Jan 2008

6.13

Mpa

Vr,max =

2205

kN

1217

mm2

An =

588

mm2

(Should be < Vf)

Af

Af =

As = Af+An

As =

1805

mm2

1860

mm2

10
7
4
3
2

15M bars
20M bars
25M bars
30M bars
35M bars

- Make sure As bars fit


(See pg. 3 for min spcg)

Avf =
(2/3) Avf =

1908
1272

Ah =

636

Add

mm2
mm2

mm2

An =

(2/3)d =

10M corbel ties within

588

363

mm2

As = Af+An

1860

mm2

As,min =

1145

mm2

mm
of the As steel (Equally spaced)

Page 2 of 3

A23.3-04 Precast Corbel Design Spreadsheet


Tension Development Length Calculations & Details for Std. Hooks In Tension

Jan 2008

Ldh = Lhb*mod factor in Cl. 12.5.3, but >8db, or >150 mm

Modification Factor = 0.70


fc' =

35

(Can use 0.70, if side cover to edge As bars is > 60 mm, back cover "c" is > 50 mm)

Mpa

Ldh-Req'd Ldh-Min Ldh-Actual

15M
20M
25M
30M
35M

189
231
298
354
422

150
156
202
239
286

550
550
550
550
550

db (mm)

mm
mm
mm
mm
mm

16.0
19.5
25.2
29.9
35.7

(Min. clr spcg bet bars)

A or G

Smin

Min bend ID

15M
20M

253
304

mm
mm

30
30

15M
20M

90
100

25M
30M
35M

403
489
589

mm
mm
mm

35
42
50

25M
30M
35M

150
200
250
(Grade 400W)

Page 3 of 3

Vous aimerez peut-être aussi