LOCATED AT:
123 sample street
Rancho Cucamonga, California 91730
PREPARED EXCLUSIVELY FOR:
Mr. & Mrs. Test Sample
INSPECTED ON:
Sunday, June 12, 2011
RECEIPT
123 sample street
Rancho Cucamonga, California 91730
(909) 532-9128
Client:
Receipt Number:
EB061211-01
Receipt Date:
Quantity
Description
Base Amount
Unit Price
Amount
$499.00
$499.00
Subtotal:
Check:
$499.00
-$499.00
Change Due
$0.00
Table of Contents
Introduction..................................................................................................................................1
Introductory Notes........................................................................................................................2
Roofing.........................................................................................................................................2
Exterior/Site/Ground.....................................................................................................................9
Structure.....................................................................................................................................22
Electrical System........................................................................................................................23
Plumbing....................................................................................................................................25
Air Conditioning..........................................................................................................................29
Heat............................................................................................................................................29
Water Heater..............................................................................................................................33
Interior........................................................................................................................................39
Bathroom....................................................................................................................................42
Bedroom.....................................................................................................................................54
Entry Area/Hall...........................................................................................................................60
Garage.......................................................................................................................................61
Kitchen.......................................................................................................................................64
Laundry Area..............................................................................................................................68
Attic............................................................................................................................................70
Insulation/Energy........................................................................................................................74
Crawl Space...............................................................................................................................74
Locations of Emergency Controls..............................................................................................79
Environmental Concerns............................................................................................................81
Introduction
We have inspected the major structural components and mechanical systems for signs of significant nonperformance, excessive or unusual wear and general state of repair. Our inspection is conducted in
accordance with the Standards of Practice of the National Association of Certified Home Inspectors. The
following report is an overview of the conditions observed.
In the report, there may be specific references to areas and items that were inaccessible. We can make no
representations regarding conditions that may be present but were concealed or inaccessible for review. With
access and an opportunity for inspection, reportable conditions may be discovered. Inspection of the
inaccessible areas will be performed upon arrangement and at additional cost after access is provided.
We do not review plans, permits, recall lists, and/or government or local municipality documents. Information
regarding recalled appliances, fixtures and any other items in this property can be found on the Consumer
Product Safety website. These items may be present but are not reviewed.
Our recommendations are not intended as criticisms of the building, but as professional opinions regarding
conditions present. As a courtesy, the inspector may list items that they feel have priority in the Executive
Summary portion of the report. Although the items listed in this section may be of higher priority in the opinion
of the inspector, it is ultimately the client's responsibility to review the entire report. If the client has questions
regarding any of the items listed, please contact the inspector for further consultation.
Lower priority conditions contained in the body of the report that are neglected may become higher priority
conditions. Do not equate low cost with low priority. Cost should not be the primary motivation for performing
repairs. All repair and upgrade recommendations are important and need attention.
This report is a "snapshot" of the property on the date of the inspection. The structure and all related
components will continue to deteriorate/wear out with time and may not be in the same condition at the close
of escrow.
Anywhere in the report that the inspector recommends further review, it is strongly recommended that this be
done PRIOR TO THE CLOSE OF ESCROW. This report is not intended for use by anyone other than the
client named herein. No other persons should rely upon the information in this report. Client agrees to
indemnify, defend and hold inspector harmless from any third party claims arising out of client's unauthorized
distribution of the inspection report.
By accepting this inspection report, you acknowledge that you have reviewed and are in agreement with all of
the terms contained in the standard National Association of Certified Home Inspectors contract provided by
the inspector who prepared this report.
Page 1
Introductory Notes
ORIENTATION
For purposes of identification and reporting, the front of this building faces east.
NOTES
The house was estimated to be approximately 93 years old.
Over the course of this inspection the temperature was estimated to be between 70 and 80 degrees.
The weather was sunny at the time of our inspection.
We make no representations as to the extent or presence of code violations, nor do we warrant the legal use
of this building. This information would have to be obtained from the local building and/or zoning department.
Sections of this building may have been remodeled. We recommend consultation with the owner to determine
if all necessary permits were obtained, inspections performed and final signatures obtained.
The scope of this inspection is limited to reasonably accessible areas. We make no attempt to move
furnishings, stored personal property, and/or vegetation. Although no problems are anticipated, removal of
these items may reveal reportable items.
This house appears to be a 'flipped' property. Although the home may be in good cosmetic condition, the client
must understand that new paint and carpet does not make a new house.
Your inspector may choose to include photos in your inspection report. There are times when only a picture
can fully explain the condition or if the client is unable to attend the inspection. Photo inclusion is at the
discretion of the inspector and in no way is meant to emphasize or highlight the only conditions that were
seen. We always recommend full review of the entire inspection report.
Roofing
A roof system consists of the surface materials, connections, penetrations and drainage (gutters and
downspouts). We visually review these components for damage and deterioration and do not perform any
destructive testing. If we find conditions suggesting damage, improper application, or limited remaining service
life, these will be noted. We may also offer opinions concerning repair and replacement. Opinions stated
herein concerning the roof are based on a limited visual inspection. These do not constitute a warranty that
the roof is, or will remain, free of leaks.
Composition Shingle
BASIC INFORMATION
Location: Covers whole building
Roof slope: Combination of steep and low pitch
Copyright 2010-2015, SPECTACULAR, JC & E Home Inspection, Erick Bradshaw EB061211-01
Page 2
Page 3
PATCHING/REPAIRS
The patching itself is substandard and leakage is probable. We recommend repair or replacement to
prevent leakage.
Page 4
FLASHINGS: OVERALL
Metal flashing has been used to seal the connections and penetrations.
The flashings are generally serviceable. Attention to the items noted, together with routine maintenance, will
keep the flashings functional and maximize their expected useful life.
CHIMNEY AT ROOF
A visual observation of the flue within the scope of a standard home inspection, may not detect defects
beyond our limited view (12 - 18 inches) or where soot has accumulated. A more thorough inspection can be
performed by a specialist.
FLUES
A flue cap is too small. We recommend it be replaced to keep out rain and debris.
Page 5
PLUMBING VENTS
There are plastic plumbing vents protruding through the roof. Standards require this type of pipe be protected
and, in most jurisdictions, this has been interpreted to mean painted for protection against the sun. We
recommend the vents be painted.
Page 6
SERVICE DROP
The splices between the overhead service drop conductors and the service entrance conductors from the
mast are exposed. We recommend the local utility company or other qualified personnel be retained to
insulate the exposed surfaces.
The service entrance conductors do not have a proper drip loop to prevent water from entering the mast. We
recommend modification of the service drop, in accordance with present standards.
Page 7
GUTTERS
The gutters are in serviceable condition, but should be checked for debris and cleaned on a regular basis to
prolong their useful life.
Page 8
GENERAL COMMENT
The roof is weathered and has been patched, an appropriate short term solution. The roof should be reviewed
periodically for indications of further deterioration and additional repairs performed as needed.
Exterior/Site/Ground
Primary
BASIC INFORMATION
General lot topography: Flat lot
Walkways: Concrete
Patio: Concrete
Primary exterior wall covering: Stucco
Page 9
Page 10
EXTERIOR PLUMBING
The plumbing on the exterior of the building and in the yard appears to be properly installed and in serviceable
condition. We make no attempt to locate and test every hose bib. Testing of irrigation systems is beyond the
scope of our inspection.
Testing of the irrigation system and/or automatic timer is beyond the scope of this inspection.
MAIN SUPPLY
There was no evidence of surface corrosion or leakage at the exposed and accessible main supply.
Page 11
GAS PIPING
The gas piping appears to be properly installed and in serviceable condition. We detected no evidence of
leakage at any of the exposed gas piping. Pressure testing may reveal leaks, but this procedure is beyond the
scope of our inspection.
SERVICE DROP
The splices between the overhead service drop conductors and the service entrance conductors from the
mast are exposed. We recommend the local utility company or other qualified personnel be retained to
insulate the exposed surfaces.
The service entrance conductors do not have a proper drip loop to prevent water from entering the mast. We
recommend modification of the service drop, in accordance with present standards.
Page 12
STUCCO
The stucco exterior is in good condition, with a few minor cracks. These hairline cracks are typical and no
action is indicated. They can be patched and sealed in the course of routine maintenance.
DOORS
The exterior doors appear to be properly installed and in serviceable condition.
The front door has been installed in a substandard manner. We recommend it be reinstalled properly.
WINDOWS
The windows appear to be properly installed and in serviceable condition.
GRADING
Grading is sloped toward the structure in some areas. Low spots and negative grading promote water
accumulation near the building, leading to foundation problems. Regrading would help ensure that surface
water flows away from the structure.
GUTTERS
Roof runoff water is channeled to the downspouts by a metal gutter system attached to the fascia boards or to
the ends of the rafters along the edge of the roof.
Copyright 2010-2015, SPECTACULAR, JC & E Home Inspection, Erick Bradshaw EB061211-01
Page 13
The gutters are filled with debris. We recommend all debris be removed to ensure proper drainage. The
condition of the gutters can be better assessed at that time.
DOWNSPOUTS
The downspouts appear to be properly installed and in serviceable condition, with exceptions noted below.
Page 14
Runoff water from the roof discharges next to the house. We recommend the downspouts be routed
sufficiently away from the structure to prevent puddling, pooling, and saturation of the soil around the building.
Page 15
DRIVEWAY
There are major cracks in the driveway. These may indicate poor soil conditions and/or poor preparation of the
substrate. The cracks could be sealed to prevent water intrusion, but replacement of the drive would be a
more permanent solution.
PATIO COVERING
The patio is covered by a permanent roof surface which is in fair to good condition.
Page 16
The rim joist/ledger at the patio cover has been installed without proper flashing. We recommend further
review by a licensed general contractor.
HAND RAILS
There are no railings where needed at the front porch. As a safety measure, we recommend that railings be
installed.
Page 17
GATES
The gates show signs of wear/deterioration and the need for maintenance.
Page 18
TRIM
As with any recently refinished and freshly painted surface, trim conditions may be present that were not
readily apparent at the time of our inspection. We do not suggest or represent that this inspection will identify
all such conditions.
Detached Structure
BASIC INFORMATION
General lot topography: Flat lot
FOUNDATION
The foundation and other visible elements of the support structure have performed well and are in good
condition for the age of the structure.
PEST CONTROL
Our observations regarding evidence of pests is not a substitute for inspection by a licensed pest control
operator or exterminator. We report current visible conditions only and cannot render an opinion regarding
their cause or remediation.
Page 19
OUTDOOR RECEPTACLES
GFCI protection was not found where this feature is now required. We recommend GFCI protection be
installed.
STUCCO
The stucco exterior is in good condition, with a few minor cracks. These hairline cracks are typical and no
action is indicated. They can be patched and sealed in the course of routine maintenance.
DOORS
The entry door is deteriorated. We recommend it be repaired or replaced.
Page 20
FASCIA
Sections of the fascia at the detached structure are damaged. We recommend they be repaired or replaced.
Page 21
GENERAL COMMENT
There are numerous areas where significant lapses in maintenance have occurred and, at this stage, exterior
problems may indicate more serious structural or systemic deficiencies. We recommend action as discussed
in the specific comments.
Structure
The structural elements of a building include foundation, footings, all lower support framing and components,
wall framing and roof framing. These items are examined, where visible, for proper function, excessive or
unusual wear and general state of repair. Many structural components are inaccessible because they are
buried below grade or behind finishes. Therefore, much of the structural inspection is performed by identifying
resultant symptoms of movement, damage and deterioration. Where there are no visible symptoms, conditions
requiring further review or repair may go undetected and identification will not be possible. We make no
representations as to the internal conditions or stabilities of soils, concrete footings and foundations, except as
exhibited by their performance.
BASIC INFORMATION
Foundation type: Slab-on-grade and raised perimeter
Slab material: Poured concrete
Exterior wall support: Wood frame
MOISTURE
There is a condition known as efflorescence on portions of the concrete foundation slab. This whitish, fuzzy
material is a 'salt' deposit left when moisture in the slab evaporates.
This often indicates an occasional surplus of moisture on the outside of the slab. Steps should be taken to
improve the exterior drainage, but no other action is indicated at this time.
PEST CONTROL
Our observations regarding evidence of pests is not a substitute for inspection by a licensed pest control
operator or exterminator. We report current visible conditions only and cannot render an opinion regarding
their cause or remediation.
Copyright 2010-2015, SPECTACULAR, JC & E Home Inspection, Erick Bradshaw EB061211-01
Page 22
Electrical System
An electrical system consists of the service, distribution, wiring and convenience outlets (switches, lights, and
receptacles). Our examination of the electrical system includes the exposed and accessible conductors,
branch circuitry, panels, overcurrent protection devices, and a random sampling of convenience outlets. We
look for adverse conditions such as improper installation, exposed wiring, running splices, reversed polarity
and circuit protection devices. We do not evaluate fusing and/or calculate circuit loads. The hidden nature of
the electrical wiring prevents inspection of every length of wire.
BASIC INFORMATION
Service entry into building: Overhead service drop
Voltage supplied by utility: 120/240 volts
METER & MAIN
The meter and main electrical service panel are outside on the rear of the building.
MAIN DISCONNECT
The main disconnect is incorporated into the electrical service panel.
Page 23
SERVICE DROP
The splices between the overhead service drop conductors and the service entrance conductors from the
mast are exposed. We recommend the local utility company or other qualified personnel be retained to
insulate the exposed surfaces.
The service entrance conductors do not have a proper drip loop to prevent water from entering the mast. We
recommend modification of the service drop, in accordance with present standards.
CB MAIN PANEL
The main service panel is in good condition with circuitry installed and fused correctly.
The circuitry in the panel is unlabeled. We recommend this be corrected to allow individuals unfamiliar with the
equipment to operate it properly when and if it becomes necessary.
SERVICE CAPACITY
The service entrance conductors are the wires between the utilities service drop and the main service
disconnect or main service panel.
Page 24
SERVICE GROUNDING
The system and equipment grounding appears to be correct.
BRANCH CIRCUITRY
The accessible branch circuitry was examined and appeared properly installed and in serviceable condition.
CONDUCTOR MATERIAL
The accessible branch circuit wiring in this building is copper.
GENERAL COMMENT
The electrical system is in good condition and the components are properly installed. No unsafe conditions
were observed in the readily accessible portions of the installation.
Plumbing
A plumbing system consists of the domestic water supply lines, drain, waste and vent lines and gas lines.
Page 25
Inspection of the plumbing system is limited to visible faucets, fixtures, valves, drains, traps, exposed pipes
and fittings. These items are examined for proper function, excessive or unusual wear, leakage, and general
state of repair. The hidden nature of piping prevents inspection of every pipe and joint. A sewer lateral test,
necessary to determine the condition of the underground sewer lines, is beyond the scope of this inspection If
desired, a qualified individual could be retained for such a test. Our review of the plumbing system does not
include landscape watering, fire suppression systems, private water supply/waste disposal systems, or
recalled plumbing supplies. Review of these systems requires a qualified and licensed specialist.
BASIC INFORMATION
Domestic water source: Public supply
Landscape water source: Public supply
Main water line: Copper
Supply piping: Copper where seen
Waste disposal: Municipal
Waste piping: Plastic where seen
Water pressure: Excessive
Recommend installing pressure reducing valve to reduce risk of pipes bursting under pressure.
Page 26
Page 27
REGULATOR
There is a regulator installed near the main shut off to maintain water pressure at an acceptable level in an
area where pressure is generally higher than normal. The regulator is damaged. We recommend it be
replaced.
Page 28
Air Conditioning
An air conditioning system consists of the cooling equipment operating and safety controls and a means of
distribution. These items are visually examined for proper function, excessive or unusual wear, and general
state of repair. Air conditioning systems are not tested if the outside temperature is too cold for proper
operation. Detailed testing of the components of the cooling equipment or predicting their life expectancy
requires special equipment and training and is beyond the scope of this inspection. This is a non-evasive,
basic function review only. We do not dismantle, uncover or calculate efficiency of any system. Regular
servicing and inspection of air conditioning equipment is encouraged.
GENERAL COMMENT
This structure has no air conditioning.
Heat
A heating system consists of the heating equipment, operating and safety controls, venting and the means of
distribution. These items are visually examined for proper function, excessive or unusual wear and general
state of repair. This is a non-evasive, basic function review only. We do not dismantle, uncover or calculate
efficiency of any system. Regular servicing and inspection of heating systems is encouraged.
Wall Heater
Detached Structure
BASIC INFORMATION
Wall heater location: Living room
Page 29
SYSTEM NOTES
Wall heaters operate by heating a stream of air moving through the unit by 'gravity' or convection. There
usually is no blower. Important elements include the heat exchanger, exhaust venting, controls, and
clearances from combustible material.
Wall heaters are simple and easily maintained, but do not distribute the heated air very efficiently. Although not
required, installation of an alternate heating system might be considered in conjunction with other upgrades
and/or remodeling.
Because the nature of the moving air stream, wall heaters tend to rapidly collect dust, animal hair, etc. in the
lower part of the unit. Regular vacuuming (with a special nozzle, if necessary) is very important for the
furnace's safe operation.
GAS SUPPLY
The gas piping includes a 90 degree shutoff valve for emergency use. The valve was not tested at the time of
inspection. This age and style of valve is normally found to be operable by hand and generally trouble free.
Page 30
GENERAL COMMENT
The heating system responded to normal operating controls. Components appear properly installed and
serviceable. Routine maintenance will keep it functional and maximize its service life.
Primary
BASIC INFORMATION
Wall heater location: primary
Page 31
Wall heaters are simple and easily maintained, but do not distribute the heated air very efficiently. Although not
required, installation of an alternate heating system might be considered in conjunction with other upgrades
and/or remodeling.
Because the nature of the moving air stream, wall heaters tend to rapidly collect dust, animal hair, etc. in the
lower part of the unit. Regular vacuuming (with a special nozzle, if necessary) is very important for the
furnace's safe operation.
GAS SUPPLY
The gas piping includes a 90 degree shutoff valve for emergency use. The valve was not tested at the time of
inspection. This age and style of valve is normally found to be operable by hand and generally trouble free.
Our inspection of the heating system is non-invasive and is limited to visible components and their basic
Copyright 2010-2015, SPECTACULAR, JC & E Home Inspection, Erick Bradshaw EB061211-01
Page 32
function. A full evaluation requires extensive testing and is beyond the scope of our inspection.
Water Heater
Our review of water heaters includes the tank, water and gas connections, electrical connections, venting and
safety valves. These items are examined for proper function, excessive or unusual wear, leakage and general
state of repair. We do not fully review tankless/on-demand systems and suggest you consult a specialist. The
hidden nature of piping and venting prevents inspection of every pipe, joint, vent and connection.
Detached Structure
BASIC INFORMATION
Location: In an outdoor closet
Page 33
GAS SUPPLY
The gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case
of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.
Page 34
VENTING
The water heater vent requires a draft hood for safe operation. We recommend that an approved draft hood
be installed.
COMBUSTION AIR
Combustion air provides the oxygen for fuel burning appliances. Adequate ventilation around all fuel burning
appliances is vital for their safe operation. The air can come from inside or outside, providing industry
standards are met.
The combustion air supply is adequate.
WATER CONNECTORS
The cold water inlet and hot water outlet connections appear properly installed and in serviceable condition.
Page 35
The water heater is equipped with a cold water inlet shut-off valve. It is functioning as designed and intended.
We recommend draining a few gallons from the unit periodically to flush sludge from the bottom of the tank.
However, water heater drain valves often become encrusted with deposits and do not completely close as the
unit gets older.
Therefore, unless the water heater is flushed regularly from the time it is new, we do not recommend operation
of the drain valve except in an emergency or when the unit is replaced.
SEISMIC RESTRAINT
The water heater tank has been secured. This feature will help prevent water heater movement and possible
gas leakage, limit damage and provide a source of usable domestic water in the event of a major earthquake.
ELEVATION/LOCATION
There does not appear to be a floor drain in the vicinity of the water heater. This condition may lead to
excessive accumulation of water should a discharge occur. This possibility should be considered before
storing sensitive items in this area.
Page 36
Primary
BASIC INFORMATION
Location: In an outdoor closet
Page 37
GAS SUPPLY
The gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case
of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.
COMBUSTION AIR
Combustion air provides the oxygen for fuel burning appliances. Adequate ventilation around all fuel burning
appliances is vital for their safe operation. The air can come from inside or outside, providing industry
standards are met.
The combustion air supply is adequate.
Page 38
WATER CONNECTORS
The cold water inlet and hot water outlet connections appear properly installed and in serviceable condition.
The water heater is equipped with a cold water inlet shut-off valve. It is functioning as designed and intended.
SEISMIC RESTRAINT
The water heater tank has been secured. This feature will help prevent water heater movement and possible
gas leakage, limit damage and provide a source of usable domestic water in the event of a major earthquake.
ELEVATION/LOCATION
There does not appear to be a floor drain in the vicinity of the water heater. This condition may lead to
excessive accumulation of water should a discharge occur. This possibility should be considered before
storing sensitive items in this area.
Interior
Our review of the interior includes inspection of walls, ceilings, floors, doors, windows, steps, stairways,
balconies and railings. These features are visually examined for proper function, excessive wear and general
Page 39
state of repair. Some of these components may not be visible/accessible because of furnishings and/or
storage. In such cases these items are not inspected.
BASIC INFORMATION
Number of bedrooms: Three
Number of bathrooms: Two
Window material: Metal
Window type: Horizontal sliding windows
Page 40
DOORS: OVERALL
The interior doors appear to be properly installed and in good condition, with the exception of the door at
the front bedroom. Attention to this door is recommended.
WINDOWS: OVERALL
We operate a representative sample of the windows, but do not necessarily open, close, and latch every
window. Our inspection standards require testing a minimum of one window in every room.
DETECTORS: OVERALL
The smoke detectors were tested with their test buttons. This method only verifies battery and horn function,
but does not test the sensor in the unit. After occupancy, and regularly thereafter, we advise testing with real or
simulated smoke.
GENERAL COMMENT
There are smoke detectors in this residence. These are reliable and inexpensive and are recommended by all
local fire districts and required by most current building departments.
Page 41
Bathroom
Bathrooms are visually inspected for proper function of components, active leakage, excessive or unusual
wear and general state of repair. Fixtures are tested using normal operating features and controls. Due to
finished surfaces such as drywall/plaster, tile, and flooring, much of the bathroom is considered inaccessible.
We do not test or confirm proper application of secondary equipment including but not limited to steam units,
spa tubs, heated towel bars, etc.
Front
DRAIN TRAP
The drain trap and associated piping are ABS plastic.
TOILET
The toilet was flushed and appeared to be functioning properly.
WATER BASIN
The wash basin appears to be properly installed. When operated, it was observed to be fully functional and in
serviceable condition.
Page 42
SHOWER
The shower was operated for the inspection and appeared to be in serviceable condition.
A water test of the shower pan is beyond the scope of this inspection. This test if often performed as a part of
a standard pest inspection.
RECEPTACLES
The receptacle appears to be properly installed and was operational.
GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety.
We recommend testing the device on a monthly basis.
GLASS ENCLOSURE
The glass on the shower door does not indicate that it is tempered or laminated safety glass. By the 'look' of
the installation it appears to be tempered. A thorough cleaning of the glass may reveal the label indicating its
composition.
Page 43
VENTILATION
Ventilation in this bathroom is provided by a ceiling fan. This fan was operated and was found to be working
satisfactorily.
Master
BASIC INFORMATION
Toilet: Ceramic unit with a porcelain finish
Wash basin: Ceramic unit with a porcelain finish
Bathtub: Molded fiberglass
Shower walls: Mortar set ceramic tile
FIXTURES
The sink faucet hot and cold water controls are reversed. Reversed hot and cold water can result in hot water
burns. We recommend that this condition be corrected.
Page 44
DRAIN TRAP
The drain trap and associated piping are ABS plastic.
TOILET
The toilet was flushed and appeared to be functioning properly.
BATHTUB
The bathtub is a free-standing tub.
SHOWER
The shower was operated for the inspection and appeared to be in serviceable condition.
A water test of the shower pan is beyond the scope of this inspection. This test if often performed as a part of
a standard pest inspection.
RECEPTACLES
The receptacle appears to be properly installed and was operational.
Page 45
GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety.
We recommend testing the device on a monthly basis.
GLASS ENCLOSURE
The glass shower enclosure is safety labeled and appears to be in good condition.
Page 46
VENTILATION
Ventilation in this bathroom is adequate.
Detached Structure
BASIC INFORMATION
Toilet: Ceramic unit with a porcelain finish
Wash basins: Ceramic units with a porcelain finish
Page 47
DRAIN TRAP
The drain trap and associated piping are ABS plastic.
TOILET
The toilet was flushed and appeared to be functioning properly.
WATER BASIN
The wash basins appear to be properly installed. When operated, they were observed to be fully functional
and in serviceable condition.
BATHTUB
The bathtub appears to be properly installed and in serviceable condition.
SHOWER
The shower was operated for the inspection and appeared to be in serviceable condition.
Page 48
A water test of the shower pan is beyond the scope of this inspection. This test if often performed as a part of
a standard pest inspection.
RECEPTACLES
The receptacle appears to be properly installed and was operational.
GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety.
We recommend testing the device on a monthly basis.
Page 49
GLASS ENCLOSURE
The glass shower enclosure is safety labeled and appears to be in good condition.
VENTILATION
Ventilation in this bathroom is adequate.
Page 50
DRAIN TRAP
The drain trap and associated piping are ABS plastic.
TOILET
The toilet was not operational. We recommend the toilet be repaired or replaced.
Page 51
WATER BASIN
The drain stop is missing. We recommend it be replaced.
There is no overflow drain. Without an overflow drain, wash basin overflow is possible. The wash basin should
never be filled while unattended.
SHOWER
A water test of the shower pan is beyond the scope of this inspection. This test if often performed as a part of
a standard pest inspection.
Page 52
Faucets keep spinning and willwill not turn off cause recommend repair immediately
Shower leaks a substantial amount from this area highly recommend repairs immediately
RECEPTACLES
The receptacle is an ungrounded three prong type. To provide an increased margin of safety, we recommend
either the receptacle be repaired and grounded or equivalently protected by adding a GFCI receptacle.
Page 53
There is no GFCI (ground fault circuit interrupter) protection for this bathroom. For an increased margin of
safety, we recommend the installation of a GFCI receptacle.
Bedroom
Master
RECEPTACLES
The receptacles were found to be properly installed and in serviceable condition. The number of receptacles is
considered adequate for the size of the room.
DOORS
The master bedroom door rubs on the frame. We recommend the weatherstripping be removed and it be
planed or sanded for smoother operation.
Page 54
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
GENERAL COMMENT
The finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time
of our inspection.
Right Front
RECEPTACLES
The receptacles were found to be properly installed and in serviceable condition. The number of receptacles is
considered adequate for the size of the room.
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Page 55
Right Rear
RECEPTACLES
The receptacles were found to be properly installed and in serviceable condition. The number of receptacles is
considered adequate for the size of the room.
FLOOR
There is a minor slope in the flooring. We noted no resulting weakness, failure or nonperformance as a result
of the slope. No immediate corrective actions are required. See foundation and/or other sections of this report
regarding this issue.
WINDOWS
One window screen is missing. We recommend it be replaced.
Page 56
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Page 57
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Page 58
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Page 59
WINDOWS
One window screen is missing. We recommend it be repaired or replaced.
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Entry Area/Hall
RECEPTACLES
The receptacles were found to be properly installed and in serviceable condition. The number of receptacles is
considered adequate for the size of the room.
Page 60
FLOOR
There is a minor slope in the flooring. We noted no resulting weakness, failure or nonperformance as a result
of the slope. No immediate corrective actions are required. See foundation and/or other sections of this report
regarding this issue.
SMOKE DETECTOR
The smoke detector alarm was activated when the test button was depressed.
Garage
Garages and/or vehicle storage areas are visually inspected for general state of repair. Due to the presence of
the storage and personal property, our review of these areas is limited.
Page 61
FRAMING
The wall framing appears properly installed and, based on conventional construction standards, is adequate to
resist lateral movement. The garage framing can usually serve as an indicator of the type and quality of the
framing in general.
WALL FRAMING
In the areas where the wall framing is visible, all components appear to be properly installed and generally in
good condition.
RECEPTACLES
There is no GFCI (ground fault circuit interrupter) protection for this area. For an increased margin of safety,
we recommend the installation of a GFCI receptacle.
Page 62
GARAGE DOORS
The garage door is a single roll up design.
Page 63
Operation of the door(s) is controlled by a motorized mechanism, more commonly referred to as an automatic
opener.
The garage door was operated and appears to be properly installed and in generally serviceable condition.
Our review of the garage door(s) does not include resistance testing of the pressure switch and/or correct
balance of the door springs. Further review by a specialty contractor is suggested.
Kitchen
The kitchen is visually inspected for proper function of components, active leakage, excessive or unusual
wear, and general state of repair. We inspect built-in appliances to the extent possible using normal operating
controls. Freestanding stoves are operated, but refrigerators, small appliances, portable dishwashers, and
microwave ovens are not tested.
Detached Structure
BASIC INFORMATION
Energy: Gas (or propane) stove with electric hook-up available
Page 64
The sink appears to be properly installed. When operated, it was observed to be fully functional and in
serviceable condition.
RECEPTACLES
The receptacles appear to be properly installed and were operational.
GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety.
We recommend testing the device on a monthly basis.
APPLIANCES: OVERALL
One or more of the built-in appliances have been removed and will need to be replaced for full use of the
kitchen as designed.
GENERAL COMMENT
The finished surfaces, hardware, windows, and doors were found to be generally in good condition at the time
of our inspection.
Page 65
Primary
BASIC INFORMATION
Energy: Gas (or propane) stove with electric hook-up available
Ventilation: Exhaust ducted to the exterior. Maintenance and finish work recommended
Page 66
DRAIN TRAPS
The drain trap and associated piping are ABS plastic.
SINK
The sink is metal.
The sink appears to be properly installed. When operated, it was observed to be fully functional and in
serviceable condition.
Page 67
GAS SUPPLY
The gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case
of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.
RECEPTACLES
The receptacles appear to be properly installed and were operational.
GFCI (ground fault circuit interrupter) protection has been installed providing an increased margin of safety.
We recommend testing the device on a monthly basis.
Laundry Area
Laundry areas and/or laundry rooms are visually inspected for general state of repair. Due to their hidden
nature, we do not review appliances, connections, hookups, or venting.
Page 68
GAS SUPPLY
The gas piping for the appliance includes a local 90 degree shut-off valve for use in an emergency or in case
of repair. The valve was not tested at the time of inspection, but is of a type usually found to be serviceable.
DRYER VENT
The dryer vent appears properly installed and in serviceable condition.
Page 69
WASHER/DRYER
The hookups for the washer and dryer are properly installed and in serviceable condition. The appliances
themselves were not tested.
Attic
The attic contains the roof framing and serves as a raceway for components of the mechanical systems.
There are often heating ducts, electrical wiring and appliance vents in the attic. We visually examine the attic
components for proper function, excessive or unusual wear, general state of repair, leakage, venting and
misguided improvements. Where walking in an unfinished attic can result in damage to the ceiling, inspection
is from the access opening only.
ACCESS/ENTRY
The attic access is located in the rear right bedroom closet.
PEST CONTROL
Our observations regarding evidence of pests is not a substitute for inspection by a licensed pest control
operator or exterminator. We report current visible conditions only and cannot render an opinion regarding
their cause or remediation.
RAFTERS
Rafters are boards that support the roof sheathing, which in turn, supports the roof covering.
Page 70
The roof structure appears to be constructed in a manner typical of houses of this type and age. The rafters
are generally in good condition, where seen, and have performed adequately since their installation.
SHEATHING
The roof sheathing is the material directly supporting the roof covering.
The roof sheathing is 'OSB' - Oriented Strand Board, nailed solidly across the rafters.
The roof sheathing generally appears to be properly installed and in good condition, with exceptions noted
below. Prior water damage noted at time of inspection monitor this area
COLLAR TIES
Collar ties are structural members connecting opposing rafters in a pair and are significant elements in the
roof structure.
Page 71
The original collar ties appear to be properly installed and are in good condition.
VENT LINES
The vent piping at the attic has been installed in a substandard manner. We recommend it be repaired or
replaced.
Page 72
VENTILATION
Our feeling regarding attic ventilation is that 'you can never have too much'. Attic ventilation can be provided
by eave, gable, and ridge vents as well as by automatic and wind driven fans. We encourage use of any or all
of the above.
The lack of adequate ventilation, when combined with cold weather and high indoor relative humidity, causes
water vapor produced inside the house to rise into the attic, causing condensation on the cold surfaces.
Condensation can promote deterioration of the roof framing and sheathing, cause mildew growth on the
ceilings, drip down to soak insulation, and reduce the serviceable life of the roof covering.
The attic is adequately vented. Good ventilation helps reduce attic moisture levels and prevents condensation
on the underside of the roof. In addition, it reduces heat build-up in the attic, making the house more
comfortable.
Page 73
Insulation/Energy
Insulation, weatherstripping, dampers, double-glazed glass and set-back thermostats are features that help
reduce heat loss and/or gain and increase system and appliance efficiency. Our visual inspection includes
review to determine if these features are present in representative locations and we may offer suggestions for
upgrading. Our review of insulation is based upon uniformly insulated or are insulated to current standards. It
is our opinion that all homes could benefit from energy conservation upgrades, and we suggest that you
consult professionals.
ATTIC INSULATION
There is no attic insulation. This is unusual in these times of high fuel costs. As an energy conservation
upgrade we recommend that R-30 insulation be installed.
Crawl Space
The crawl space is where most of the building's structural elements and portions of its mechanical systems
are located. These include foundation, structural framing, electrical, plumbing and heating. Each accessible
and visible component and system is examined for proper function, excessive or unusual wear and general
state of repair. It is not unusual to find occasional moisture and dampness in crawl spaces. Significant and/or
frequent water accumulation can adversely affect the building foundation and support system and would
indicate the need for further evaluation by a specialist. Although observed in the crawl space, some items will
be reported under the individual systems to which they belong.
Page 74
BASIC INFORMATION
Foundation type: Raised perimeter with isolated piers
ACCESS
The crawl space is accessible from an exterior hatch.
Page 75
MUDSILL
The mudsill is the wood member resting directly on the foundation. The mudsill is installed in a substandard
manner by today's standards. However, no adverse conditions have resulted and we would considered
upgrades to be optional.
FLOOR JOISTS
The floor framing is marginal. Should conditions or uses change over time, the existing configuration could fail.
We recommend this area be repaired or modified to conform to accepted standards.
POSTS
The floor system is supported by wooden posts set over concrete pier blocks.
Page 76
The bottoms of the posts are supported at or below the grade of the crawl space soil. This condition is
conducive to deterioration. Action should be taken to insure that a 6 inch clearance is maintained between
wood and soil.
ANCHOR BOLTS
Anchor bolts are fasteners that connect the wood framing to the foundation. They limit the framing's ability to
move independently on the foundation in the event of seismic activity.
The foundation is anchored using older technology. The original configuration has performed adequately to
date. Upgrades might be considered as part of any future modernization and/or remodeling, but we do not
consider this an urgent matter.
MOISTURE
The soil was damp at the time of our inspection, however, there were no adverse conditions or damage
observed resulting from the moisture conditions present to date.
To keep the moisture infiltration to a minimum, we recommend that all surface drainage, including water from
the downspouts, be directed as far away from the building as possible. Watering landscaping should be
minimized and controlled.
Page 77
VAPORT BARRIER
There is no vapor barrier in place in this crawl space. A vapor barrier is considered a beneficial feature and we
recommend one be installed.
This will help create a dry air space between the damp soil and the framing and limit the amount of moisture
that is able to rise into the framing, and reduce the possibility of future moisture damage.
The vapor barrier will also help keep the moisture content of the soil at an equilibrium and minimize changes
in soil moisture that can cause movement in the support structure.
Lastly, a vapor barrier will provide a more hospitable surface to crawl on when access to the crawl space is
required during the rainy season.
VENTILATION
Ventilation in the crawl space is adequate. Good ventilation in the crawl space is important to keep moisture
levels down. Keeping the vents clear of debris and vegetation should be part of regular maintenance.
GAS PIPING
The gas piping appears to be properly installed and in serviceable condition. We detected no evidence of
leakage at any of the exposed gas piping. Pressure testing may reveal leaks, but this procedure is beyond the
scope of our inspection.
Page 78
Primary
GAS METER LOCATION
EXTERIOR/SITE/GROUND
The gas meter is outside at the front of the building. The main gas supply shutoff valve is located on the riser
pipe between the ground and the meter. This valve should be turned 90 degrees (either way) in order to shut
off the gas.
Page 79
MAIN DISCONNECT
ELECTRICAL SYSTEM
The main disconnect is incorporated into the electrical service panel.
Page 80
Environmental Concerns
Environmental issues include but are not limited to radon, fungi/mold, asbestos, lead paint, lead
contamination, toxic waste, formaldehyde, electromagnetic radiation, buried fuel oil tanks, ground water
contamination and soil contamination. We are not trained or licensed to recognize or discuss any of these
materials. We may make reference to one of more of these materials in this report when we recognize one of
the common forms of these substances. If further study or analysis seems prudent, the advice and services of
the appropriate specialists are advised.
Page 81
The general home inspection is based on the observations made on the date of the inspection, and not a
prediction of future conditions. !
II.
The general home inspection will not reveal every issue that exists or ever could exist, but only those
material defects observed on the date of the inspection.
1.2. A material defect is a specific issue with a system or component of a residential property that may have a
significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact
that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material
defect.
1.3. A general home inspection report shall identify, in written format, defects within specific systems and
components defined by these Standards that are both observed and deemed material by the
inspector. Inspection reports may include additional comments and recommendations.
2. cable
H.
III.
A.
3. Standards of Practice
3.1. Roof
I.
A.
B.
C.
D.
E.
A.
II.
III.
A.
IV.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
3.2. Exterior
I.
A.
B.
C.
D.
E.
F.
G.
H.
I.
II.
A.
III.
A.
IV.
A.
A.
B.
II.
III.
A.
B.
C.
D.
IV.
A.
B.
C.
D.
E.
F.
3.4. Heating
I.
A.
A.
B.
C.
II.
III.
A.
B.
IV.
A.
B.
C.
D.
E.
F.
G.
H.
determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply
adequacy of the heating system.
light or ignite pilot flames.
activate heating, heat pump systems, or other heating systems when ambient temperatures or other
circumstances are not conducive to safe operation or may damage the equipment.
override electronic thermostats.
evaluate fuel quality.
verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.
3.5. Cooling
I.
A.
A.
B.
II.
III.
A.
B.
IV.
A.
B.
C.
D.
E.
3.6. Plumbing
I.
D.
E.
F.
G.
H.
A.
B.
C.
D.
A.
B.
C.
II.
E.
III.
A.
B.
C.
D.
IV.
A.
B.
C.
3.7. Electrical
I.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
L.
a representative number of switches, lighting fixtures and receptacles, including receptacles observed
and deemed to be arc-fault circuit interrupter (AFCI)-protected using the AFCI test button, where
possible;
all ground-fault circuit interrupter receptacles and circuit breakers observed and deemed to be GFCIs
using a GFCI tester, where possible; and
smoke and carbon-monoxide detectors.
A.
B.
K.
II.
III.
A.
B.
C.
D.
E.
IV.
A.
3.8. Fireplace
I.
A.
B.
C.
D.
II.
A.
III.
A.
B.
C.
D.
E.
IV.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
G.
H.
determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers or wiring.
determine the adequacy of ventilation.
A.
II.
III.
A.
B.
C.
IV.
A.
B.
C.
D.
E.
F.
G.
W. determine the adequacy of whirlpool or spa jets, water force, or bubble effects.
X. determine the structural integrity or leakage of pools or spas.
4. Glossary of Terms
accessible: In the opinion of the inspector, can be approached or entered safely, without difficulty, fear or
danger.
activate: To turn on, supply power, or enable systems, equipment or devices to become active by normal
operating controls. Examples include turning on the gas or water supply valves to the fixtures and
appliances, and activating electrical breakers or fuses.
adversely affect: To constitute, or potentially constitute, a negative or destructive impact.
alarm system: Warning devices, installed or freestanding, including, but not limited to: carbon-monoxide
detectors, flue gas and other spillage detectors, security equipment, ejector pumps, and smoke alarms.
appliance: A household device operated by the use of electricity or gas. Not included in this definition are
components covered under central heating, central cooling or plumbing.
architectural service: Any practice involving the art and science of building design for construction of any
structure or grouping of structures, and the use of space within and surrounding the structures or the
design, design development, preparation of construction contract documents, and administration of the
construction contract.
component: A permanently installed or attached fixture, element or part of a system.
condition: The visible and conspicuous state of being of an object.
correction: Something that is substituted or proposed for what is incorrect, deficient, unsafe, or a defect.
cosmetic defect: An irregularity or imperfection in something, which could be corrected, but is not required.
crawlspace: The area within the confines of the foundation and between the ground and the underside of the
lowest floor's structural component.
decorative: Ornamental; not required for the operation of essential systems or components of a home.
describe: To report in writing a system or component by its type or other observed characteristics in order to
distinguish it from other components used for the same purpose.
determine: To arrive at an opinion or conclusion pursuant to examination.
dismantle: To open, take apart or remove any component, device or piece that would not typically be
opened, taken apart or removed by an ordinary occupant.
engineering service: Any professional service or creative work requiring engineering education, training
and experience, and the application of special knowledge of the mathematical, physical and engineering
sciences to such professional service or creative work as consultation, investigation, evaluation,
planning, design and supervision of construction for the purpose of assuring compliance with the
specifications and design, in conjunction with structures, buildings, machines, equipment, works and/or
processes.
enter: To go into an area to observe visible components.
evaluate: To assess the systems, structures and/or components of a property.
evidence: (noun form) That which tends to prove or disprove something; something that makes plain or
clear; ground for belief; proof.
examine: To visually look (see inspect).
foundation: The base upon which the structure or wall rests, usually masonry, concrete or stone, and
generally partially underground.
function: The action for which an item, component or system is specially fitted or used, or for which an
item, component or system exists; to be in action or perform a task.
functional: Performing, or able to perform, a function.
functional defect: A lack of or an abnormality in something that is necessary for normal and proper
functioning and operation, and, therefore, requires further evaluation and correction.
general home inspection: The process by which an inspector visually examines the readily accessible
systems and components of a home and operates those systems and components utilizing these
Standards of Practice as a guideline.
home inspection: See general home inspection.
household appliances: Kitchen and laundry appliances, room air conditioners, and similar appliances.
identify: To notice and report.
indication: (noun form) That which serves to point out, show, or make known the present existence of
something under certain conditions.
inspect: To examine readily accessible systems and components safely, using normal operating controls, and
accessing readily accessible areas, in accordance with these Standards of Practice.
inspected property: The readily accessible areas of the buildings, site, items, components and systems
included in the inspection.
inspection report: A written communication (possibly including images) of any material defects observed
during the inspection.
inspector: One who performs a real estate inspection.
installed: Attached or connected such that the installed item requires a tool for removal.
material defect: A specific issue with a system or component of a residential property that may have a
significant, adverse impact on the value of the property, or that poses an unreasonable risk to
people. The fact that a system or component is near, at or beyond the end of its normal useful life is not,
in itself, a material defect.
normal operating controls: Describes the method by which certain devices (such as thermostats) can be
operated by ordinary occupants, as they require no specialized skill or knowledge.
observe: To visually notice.
operate: To cause systems to function or turn on with normal operating controls.
readily accessible: A system or component that, in the judgment of the inspector, is capable of being safely
observed without the removal of obstacles, detachment or disengagement of connecting or securing
devices, or other unsafe or difficult procedures to gain access.
recreational facilities: Spas, saunas, steam baths, swimming pools, tennis courts, playground equipment,
and other exercise, entertainment and athletic facilities.
report: (verb form) To express, communicate or provide information in writing; give a written account
of. (See also inspection report.)
representative number: A number sufficient to serve as a typical or characteristic example of the item(s)
inspected.
residential property: Four or fewer residential units.
residential unit: A home; a single unit providing complete and independent living facilities for one or more
persons, including permanent provisions for living, sleeping, eating, cooking and sanitation.
safety glazing: Tempered glass, laminated glass, or rigid plastic.
shut down: Turned off, unplugged, inactive, not in service, not operational, etc.
structural component: A component that supports non-variable forces or weights (dead loads) and variable
forces or weights (live loads).
system: An assembly of various components which function as a whole.
technically exhaustive: A comprehensive and detailed examination beyond the scope of a real estate home
inspection that would involve or include, but would not be limited to: dismantling, specialized
knowledge or training, special equipment, measurements, calculations, testing, research, analysis, or
other means.
unsafe: In the inspector's opinion, a condition of an area, system, component or procedure that is judged to
be a significant risk of injury during normal, day-to-day use. The risk may be due to damage,
deterioration, improper installation, or a change in accepted residential construction standards.
verify: To confirm or substantiate.
These terms are found within the Standards of Practice. Visit InterNACHI's full Glossary.