Académique Documents
Professionnel Documents
Culture Documents
PROPIETARIO:
ING. ELECTRICISTA:LESBIA LEIVA V. C.I.V. 67.797
TABLA DE CARGA
FECHA:
7/7/2013
TABLERO
TIPO
INTERRUPTOR PRINCIPAL
CAPAC.
RUPTURA
TP
TABLERO NLAB3412AB
3x40A
10kA
UBICACI
N
CARGA (kVA)
FACTOR DE
DEMANDA
RESERVA
(kVA)
DEMANDA
(kVA)
AMPxFASE
CALIBRE
ALIMENT.
CALIBRE
NEUTRO
13.76
0.67
9.3
25.73
3 TTU # 8
1 TTU # 10 (N)
CALIBRE
TIERRA
CANALIZ.
1TW # 12
1=1"
SALIDAS
C
I
R
C
U
I
T
O
T
E
C
H
O
P
A
R
E
D
P
I
S
O
T
/
C
E
S
P
E
C
I
A
L
CARGA
PUNTOS
(VA)
PROT.
CARGA
CTO.
CIRCUITO (A)
(VA)
CA
FASE
PROTECCION
3x40A
DESCRIPCION
1.3
1410
1410
2x20
A,B
LOCALES 1 Y 2
2.4
4420
4420
2x30
A,B
LOCAL 3
5.7
2120
2120
2x20
A,C
LOCAL 4
A,C
RESERVA
6.8
9.11
3050
3050
2x20
B,C
LOCAL 6
10.12
2760
2760
2x20
B,C
LOCAL 5
FD=
0.67
13760 VA
9264 VA
PROYECTO:
Jul-13
FD
DEM
1.00
0.70
1.40
1.40
1.00
2.00
0.80
0.30
0.4
0.12
0.40
0.05
0.15
3.00
0.90
0.135
0.14
0.00
1.00
1.00
0.00
AIRE ACONDICIONADO
2.00
2.00
SUB-TOTAL (kVA)
TOMACORRIENTES
0.50
TOMACORRIENTES (EQUIPOS DE COMPUTACION)
0.20
TOMACORRIENTES
0.90
SUB-TOTAL (kVA)
ILUMINACIN
ILUMINACION INTERIOR
SUB-TOTAL (kVA)
RESERVA
3.05
ALIMENTADORES
1.94
PROYECTO:
Jul-13
FD
DEM
1.00
0.70
1.40
1.40
1.00
1.00
0.80
0.30
0.4
0.06
0.46
0.02
0.06
3.00
0.90
0.05
0.05
0.00
1.00
1.00
0.00
AIRE ACONDICIONADO
2.00
2.00
SUB-TOTAL (kVA)
TOMACORRIENTES
0.50
TOMACORRIENTES (EQUIPOS DE COMPUTACION)
TOMACORRIENTES
SUB-TOTAL (kVA)
0.20
0.70
ILUMINACIN
ILUMINACION INTERIOR
SUB-TOTAL (kVA)
RESERVA
2.76
ALIMENTADORES
1.91
PROYECTO:
Jul-13
FD
DEM
AIRE ACONDICIONADO
0.00
0.00
0.00
SUB-TOTAL (kVA)
TOMACORRIENTES
0.50
TOMACORRIENTES (EQUIPOS DE COMPUTACION)
0.20
TOMACORRIENTES
2.00
5.00
0.80
0.30
0.8
0.3
1.10
0.015
0.12
8.00
0.90
0.11
0.11
0.00
1.00
1.00
0.00
2.00
SUB-TOTAL (kVA)
ILUMINACIN
ILUMINACION INTERIOR
SUB-TOTAL (kVA)
RESERVA
2.12
ALIMENTADORES
1.21
PROYECTO:
Jul-13
FD
DEM
1.00
0.70
1.68
1.68
3.00
1.00
0.80
0.30
1.2
0.06
1.26
0.08
0.32
4.00
0.90
0.29
0.29
0.00
1.00
1.00
0.00
AIRE ACONDICIONADO
2.40
2.40
SUB-TOTAL (kVA)
TOMACORRIENTES
0.50
TOMACORRIENTES (EQUIPOS DE COMPUTACION)
TOMACORRIENTES
SUB-TOTAL (kVA)
0.20
1.70
ILUMINACIN
ILUMINACION INTERIOR
SUB-TOTAL (kVA)
RESERVA
4.42
ALIMENTADORES
3.23
PROYECTO:
Jul-13
FD
DEM
1.00
0.70
0.42
0.42
1.00
1.00
0.80
0.30
0.4
0.06
0.46
0.01
0.11
11.00
0.90
0.10
0.10
0.00
1.00
1.00
0.00
AIRE ACONDICIONADO
0.60
0.60
SUB-TOTAL (kVA)
TOMACORRIENTES
0.50
TOMACORRIENTES (EQUIPOS DE COMPUTACION)
0.20
TOMACORRIENTES
0.70
SUB-TOTAL (kVA)
ILUMINACIN
ILUMINACION INTERIOR
SUB-TOTAL (kVA)
RESERVA
1.41
ALIMENTADORES
0.98