GE Power & Water

Waukesha* gas engines

VHP

P9390GL
1320 - 1980 BHP (984 - 1476 kWb)

VHP engines have been powering the worlds energy


infrastructuredriving compressors in gas gathering,
processing and transmission operations and providing
electrical power for oil and gas fields in remote corners of
the globe for over five decades.

Backed by more than a century of engine building


experience, GEs Waukesha engines are a sound
investment that oer durable designs that perform
reliably in remote applications and tolerance for variable
fuel quality that maximizes power output, uptime and
profitability.

technical data
Cylinders
Piston displacement
Compression ratio
Bore & stroke

V16
9388 cu. in. (154 L)
10.5:1
9.375 x 8.5 (238 mm x 216 mm)

Jacket water system capacity

148 gal. (560 L)

Lube oil capacity

165 gal. (625 L)

Starting system

Dimensions l x w x h inch (mm)


184.09 (4676) x 77.86 (1978) x 112.00 (2845)

Weights lb (kg)
28,750 (13041)

125 - 150 psi air/gas 24V electric

*Trademark of General Electric Company

performance data
Intercooler Water Temperature 130F (54C)

1200 RPM

1000 RPM

Power bhp (kWb)

1980 (1476)

1650 (1230)

BSFC (LHV) Btu/bhp-hr (kJ/kWh)

7198 (10184)

7079 (10017)

Fuel Consumption Btu/hr x 1000 (kW)

14253 (4176)

11680 (3423)

NOx g/bhp-hr (mg/Nm @ 5% O2)

1.50 (607)

1.50 (607)

CO g/bhp-hr (mg/Nm3 @ 5% O2)

2.70 (1073)

2.70 (1073)

NMHC g/bhp-hr (mg/Nm @ 5% 02)

1.00 (405)

1.00 (405)

THC g/bhp-hr (mg/Nm3 @ 5% O2)

5.50 (2227)

5.50 (2227)

Emissions

Intake/
Exhaust
System

Heat
Balance

Heat to Jacket Water Btu/hr x 1000 (kW)

3463 (1015)

3126 (916)

Heat to Lube Oil Btu/hr x 1000 (kW)

623 (183)

520 (152)

Heat to Intercooler Btu/hr x 1000 (kW)

770 (226)

633 (186)

Heat to Radiation Btu/hr x 1000 (kW)

395 (116)

346 (101)

Total Exhaust Heat Btu/hr x 1000 (kW)

4237 (1242)

3082 (903)

Induction Air Flow scfm (Nm3/hr)

4890 (7516)

4008 (6160)

21220 (9625)

17390 (7888)

762 (406)

675 (357)

Exhaust Flow lb/hr (kg/hr)


Exhaust Temperature F (C)

All data according to full load and subject to technical development and modification.
Consult your local GE Power & Waters representative for system application assistance. The manufacturer reserves the right to change or modify without notice, the design or
equipment specifications as herein set forth without incurring any obligation either with respect to equipment previously sold or in the process of construction except where
otherwise specifically guaranteed by the manufacturer.

GE Power & Water


1101 West Saint Paul Ave.
Waukesha, WI 53188-4999
P: 1.262.547.3311
F: 1.262.549.2759

Visit us online at:


www.ge-waukesha.com
2013 General Electric Company
All Rights Reserved
7006 0413 GEA-18913