Vous êtes sur la page 1sur 4

How to connect Hypertherm PMX 65

with CNC cutting machine

1 When CNC cutting machine is equipped with automatic THC, 6 wires of the
cable need to be connected between the CNC cutting machine and the plasma
power source.
According to the

Corresponding interface of PMX85

sticker on the wires


of the cable
CNC START

CNC START

DIV FINISH

12

DIV FINISH

14

DIV ARC+
DIV ARC-

J27
J29

2. When CNC cutting machine is not equipped with automatic THC, 4 wires of the
cable need to be connected between the CNC cutting machine and the plasma
power source.
According to the

Corresponding interface of PMX85

sticker on the wires


of the cable
CNC START

CNC START

DIV FINISH

12

DIV FINISH

14

3. Definition to each wire of cable of the CNC cutting machine


Signal

Type

Note

CNC START

output

Normal open: dry contact closure;


used for torch ignition.

CNC START
DIV ARC+

Input

Receive the signal of raw arc


voltage from plasma. Can receive
the arc voltage from 50VDC to

DIV ARC-

300VDC.
DIV FINISH

Input

Normal open: dry contact closure;


Receive the signal of OK TO
MOVE from plasma; it is the
signal sent by plasma source to

DIV FINISH

CNC

machine,

to

give

the

feedback that the torch is well


ignited and ready to move.

Note
1. The portable CNC cutting machine must be well grounded separately and the
grounding resistance should be less than 3.
2. The arc voltage of the plasma shall be processed by the secondary rectification,
normally, its value should be 50VDC~300VDC.
3. Any false connection by user may cause machine itself damage or even cause
injury to persons.
4. Any damage to the machine due to users false connection shall not be included
in its warranty. Any injury to persons due to users false connection shall not be
the responsibility of our side.

Vous aimerez peut-être aussi