Vous êtes sur la page 1sur 6
2 2 a je = 3 8 8 2 z = ie S fz & S 8 DESCRIPTION PAGE No. ‘TDS & CURVE 2706 FOR MOTOR FOR SUMP PUMPS NT LUNDY. [iahsl: ENT & LUNDY LTD. 7 at OBO. zr staus_ | Contract | customer: srRRUTION ‘SHREE SINGAII TPP STAGES @XedOMW) CONSULTANT: LAT-SARGENT & LUNDY LaNTTED MADHYA PRADESH POWER GENERATING COMPANY IMITED T ‘Bia [Seay Bae sea) | GHARAT HEAVY ELECTRICALS LTD. [EP | — [aah POWER SECTOR cone |B LUTLER | Prosecr encineerinc Maxacement |W joes 1EW DELL oi VENDOR: SU PUMPS” ime: TDS & CURVE FOR MOTOR FOR_ SUMP PUMPS. oes] sca BeCAMENT HO: ’ M5 SIGN PE-V8-327-172-NOO3. tentes bo. Bape a =~ Ash. DATE: 20/08/2011, REV.02 DE LT MOTORS A (GENERAL i Manufacturer & Country of origin. ‘SU MOTORS PVT.LTD. = Equipment driven by motor DOL 3. Motor type INDUCTION 4 Quantity 04 NOS. B. DESIGN AND PERFORMANCE DATA 1._| Frame size 132M 2.__| Type of duty St 3.__| Type of enclosure /Method of cooling/ Degree of protection | 1P 68 4._| Applicable standard to which motor generally conforms _| 15 325 5. _| Bifciency class as per IS 12615 NA 6.__| (@)Whether motor is flame proof No (b)IF yes, the gas group to which it conforms as per NA 7__| Type of mounting VERTICAL 8.__| Direction of rotation as viewed from DE END. CLOCKWISE Standard continuous rating at 40 deg.C. ambient temp. as | 7.5 KW per Indian Standard (kW) 30, | Derated rating for specified normal condition Le. 50 deg. C | 6.0 KW ambient temperature (KW) 11, | Maximum continuous toad demand of driven equipment in | 6.05 KW 12, | Rated Voltage (volts) 415 £10%V 13. | Permissible variation of : 2. Voltage (Volts) #10% b, Frequency (H2) +536 He & ab He [\ ¢. Combined voltage and frequency #10% E 14, | Rated speed at rated voltage and frequency(RPM) 1450 AT 415V & 50 Hz 15. | At rated Voltage and frequency: a. Full load current 16.5 AMPS, . No load current 4-5 AMPS. 16. | Power Factor at ‘a. 100% load 0.814 b. NO load 0.12 . Starting. 0.32 . 17. | Efficiency at rated voltage and frequrecy, 2.100% load 90.9% b. 75% load =] e5.5% © 50% load 68% 18. | Starting current (amps) at 2. £00 % voltage 36 Anips, . 85% voltage 102 Arps c. 80% voltage 107 Amps. 79, | Minimum permissible starting Voltage (Volts) 352 VOLTS, 20. | Starting time with minimum permissible voltage 2. Without driven equipment coupled 273 SEC, , With driven equipment coupled 4-5 56 Di, | Safe sal time with 100% and 110% of rated voltage 3, From hot condition SSC. . From cold condition 40 SEC, Za, | Toraves 2. Starting torque at min, permissible vohage(ke-mtr) 10 KEM. Pull up torque at rated voltage. 35 KGN. & Pal out torque TSKGN. Min accelerating torque (kg.m) available at lowest Permissible starting voltage ‘Atleast 10% of FLT Rated toraue (kg.m) 5.07 KEM. Ba. | Stator winding resistance per phase (ohms at 20 Deg.C) | 1970 24. GD? value of motors 0.134 KG-M" FE. No of permissible successive stars when motors Inhot | 06 NOS. 36. | Locked Rotor KVA Input 257 KVA W. Locked Rotor KVAKW 62 7 28. | ibration amit weloaty (Tay 1.8 WM 7 SEC. 39. Noise level iit (dBA) a5 db 30. ‘No. of Hot Starts / Cold starts 2 Hot / 3 Cold ‘CONSTRUCTIONAL FEATURES - 1. | Stator winding insulation [WINDING INSULATION SHOULD /\ ’F’ CLASS: BE CLASS ‘F'WITH TEMP RISE LIMITED TO CLASS 'B') a. Class & Type 'F” CLASS, INDUCTION. B. Winding Insulation Process DEEPING . Tropicalised Yes. d. Temperature rise over specified maximum ambient temperature of 50 deg C 70 DEG.C . Method of temperature measurement HOT RESISTANCE f, Stator winding connection DOL Main Terminal Box 2. Type NA B. Location(viewed from NDE side) NA . Entry of cables(bottom/side) ToP 4. Recommended cable size (To be matched with cable size envisaged by owner) POWER CABLE 40x 6 SQ.MM, CONTROL CABLE 3CX 2.5 SQ.MM,PVC INSULATED COPPER CABLE . Fault level (MYA) Fault level duration(sec) . Cable glands & lugs details (shall be suitable for power | RV,B&E 3: ‘Type of DE/NDE Bearing 6206 7 6309 4. Motor Paint shade 632 OF IS: 5 [LIGHT GREY a Weight of '@. Motor stator (KG) 60 KG. . Motor Rotor (KG) 12 KG. . Total weight (KG) 72KG. List of 1.3. | Space Heaters (Nos./Power in watts/supply voltage) NA 2. Terminal Box for Space Heater (Yes/No) NA 3. Speed switch (Yes/No) YES {MOUNTED ON No. of contacts _and contact ratings of speed switch MOTOR SHAFT) a Insulation of bearing (Yes/No) NA, 5 Noise reducer(¥es/No) NA 6 Grounding pads i) No.and size on motor body 2NOS. ii) Nos. on terminal Box NA 7. ‘Any other fitments NA List of curves. ae “Torque speed characteristic of the motor ENCLOSED 2: ‘Thermal withstand characteristic ENCLOSED 3 Starting. current Vs. Time ENCLOSED & Starting. current Vs speed ENCLOSED 5 PF and Effi. Vs Load ENCLOSED Deb MOTOR CHARACTERISTIC CURVES PUMP MODEL :~ SK-403/100-250 KW/H.P. == 7.5/10 CLASS OF INSUL :-F Q@ DEWATERING PUMP MOTOR Sr. NO. SUPPLY := 415V, 3PH, SOHZ RPM :~ 1450 * ORQUE-SPEED CURVE (DOL) | | | seo J % RATED TORQUE o 2406080 100 % SYNCH-SPEED THERMAL WITHSTAND CURVE 10009 $a 1000 | COLD (IN SEC) TIME ° 200 400 600 00 % FLC STARTING CURRENT-TIME IN SEC. STARTING CURRENT, pu sess TIME IN SEC. CUSTOME! P.O. NO. CURVE NO.:-SK-1352/2 CURVE DATE -24/05/2011 BHEL , A/C. 2x600 MW SHREE SINGHJEE TPP + PW/PE/PG/MAL/P-1738/10 DTD. 14/03/2011 DRAWN BY CHECKED BY APPROVED BY ‘SANGEETA REV. - 0 PAGE : 4 of 5 MOTOR CHARACTERISTIC CURVES @ DEWATERING PUMP MOTOR Sr.NO.:=~ PUMP MODEL := SK-403/100-250 SUPPLY i= 415V, 3PH, SOHZ RPM :- 1450 -KW/H.P. + 7.5/10 CLASS OF INSUL:-F | SU PUMPS SUS REF. + CO-1231 CURRENT VS SPEED CURVE CURRENT, PU ° 20 40 60 80 100 SPEED, % LOAD VS PF CURVE 25 50 75 100 LOAD, °% A, LOAD VS EFFICIENCY CURVE : g 100 a 37 + E 5 & 2s 28 50 75 100 LOAD, % CUSTOMER :- BHEL , A/t . 2 x 600 MW SHREE SINGHJEE TPP P.O, NO. := PW/PE/PG/MAL/P-1738/10 DTD. 14/03/2011 DRAWN BY CHECKED BY APPROVED BY (CURVE NO.:-SK-1352/1 CURVE DATE - 24/05/2011 Rev, -0 SANGEETA PAGE : 5 of 5

Vous aimerez peut-être aussi