Seleccin de sistema de desinfeccin por lmparas UV

ianium UV Disinfection system for seawater desalination RO plant 52GPM


11.8m3/hour 110Watts

Specifications

Model
ST201
Flow rate ( gpm / m3/hour )
10 / 2.3
Inlet/outlet port ( FNPT/ BSP / DIN)3/4"
Reactor size (cm )
30 x 9
Lamp watts (W)
30
Power consumption ( W )
39
Ballasts controller
Max current

ST321
ST411
ST601
ST741
18 / 4.1 24 / 5.5 35 / 7.9 42 / 9.5
3/4"
1"
1"
1 1/2"
52 x 9
61 x 9
80 x 9
94 x 9
36
45
65
80
42
52
73
88
17.6 x 7.4 x 5.3 cm / 6.9" x 2.9" x 2.1"
1.1Amp

Operation parameters:

Max operating pressure: 125psi ( 8.62bar )


Ambient water temperature: 2 - 40 ( 36 - 104 )
Hardness: < 7 gpg ( 120 mg/L )
Iron: < 0.3ppm ( 0.3 mg/L)
Turbidity: < 1NTU
UV transmittance: > 75%

Control:

Lamp life time countdown


Lamp replacement reminder

Total running / operating days


Reset timer
Audible alarm
Lamp operation indicators
4-log ( 99.99% ) Reduction of bacteria, viruses , protozoan Cysts
Reactor chamer: Mirror polished SUS304 / 316L / Titanium
Intallation type: vertical / Horizontal upon request

Description:
UV is versatile technology used for disinfecting water, other opaque liquids, hard surfaces and air.
Using the same germicidal rays as the sun, but hundreds of times stronger UV offers a reliable, co
st effective, environmentally friendly alternative to chemicals and their resulting biproducts. UV S
terilization is a purely physical process not a chemical
one so it doesnt alter waters chemistry, taste, smell or pH.

ST951
52 / 11.8
1 1/2"
115 x 9
100
110

Vous aimerez peut-être aussi