Vous êtes sur la page 1sur 5

4.

1 Data Pengamamatan
1. Laju Fluida Panas Tetap laju Fluida dingin berubah
t0
t1
t2
t3
t4
t5

Thi (C)
44
54
44
40
30
34

Tci (C)
22
22
23
23
22
24

Tho (C)
30
35
26
24
23
25

Tco(C)
25
26
26
26
26
26

laju panas (Kg/5s)


7.12
7.12
7.12
7.12
7.12
7.12

laju dingin (Kg/5s)


5.88
5.31
5.96
6.4
6.62
6.6

2. Laju Fluida panas tetap Laju Fluida dingin berubah


Thi
(C)
t0 50
t1 44
t2 44
t3 42
t4 41
t5 44
3. Laju Fluida

24
34
28
3.25
24
30
28
3.25
25
29
28
3.25
25
29
28
3.25
25
29
28
3.25
25
30
28
3.25
panas Berubah Laju fluida dingin tetap

Thi (C)
t0 54
t1 40
t2 50
t3 50
t4 48
t5 44
4. Laju Fluida

Tci (C) Tho (C) Tco(C) laju panas (Kg/5s)


25
35
30
3.76
25
30
29
3.78
25
36
30
3.84
26
38
30
4.1
26
36
30
3.82
26
35
29
3.9
panas berubah Laju fluida dingin berubah

laju dingin (Kg/5s)


3.72
3.72
3.72
3.72
3.72
3.72

Tci (C)
26
24
24
23
23
24

laju dingin (Kg/5s)


5.2
5.2
5.2
5.2
5.2
5.2

t0
t1
t2
t3
t4
t5

Thi (C)
43
49
52
56
53
44

Tci (C)

Tho (C)

Tho (C)
34
35
31
35
41
33

Tco(C)

Tco(C)
29
28
27
29
28
27

laju panas (Kg/5s)

laju panas (Kg/5s)


3.86
3.65
5.88
4.76
3.42
3.9

laju dingin
(Kg/5s)
2.06
3.46
4.6
4.62
5.2
5.98

HASIL PENGOLAHAN DATA


a. Laju alir panas tetap dingin berubah RUN 1
Laju Alir Panas
Tetap (Kg/s)

Laju Alir Dingin


(berubah) (Kg/s)

U Neraca Energi
20.6223399
7
23.4905714
2

1.348

1.1

1.348

0.986

1.348

1.116

#NUM!

1.348

1.204

#NUM!

1.348

1.248

#NUM!

1.348

1.244

#NUM!

U Empiris
9.95559777
9
9.96117967
7
10.3574433
6
9.98692244
2
10.3488466
7
9.93316149
1

b. Laju alir panas tetap dingin berubah RUN 2


Laju Alir Panas
Tetap (Kg/s)
0.574

Laju Alir Dingin


(berubah) (Kg/s)
0.336

0.574

0.616

0.574

0.844

0.574

0.848

0.574

0.964

0.574

1.12

U Neraca Energi
8.86465069
8
5.15560621
2
3.29637500
4
3.56833693
3
3.72478107
8
80.0590959
5

U Empiris
8.18715166
7
8.14231832
4
8.13555816
8.12202852
8
8.11525991
8
8.14231832
4

c. Laju alir dingin tetap panas berubah RUN 1


Laju Alir Panas
Tetap (Kg/s)

Laju Alir Dingin


(berubah) (Kg/s)

0.668

0.676

0.668

0.68

0.668

0.692

0.668

0.744

U Neraca Energi
9.34546566
2
4.71200973
4
11.6474254
8
15.1028341
7

U Empiris
8.50598761
3
8.44047177
6
8.52590361
8.67688497
3

0.668

0.688

0.668

0.704

12.6542140
1
14.2908538
4

8.51665904
6
8.54562336
3

d. Laju alir dingin tetap panas berubah RUN 2


Laju Alir Panas
Tetap (Kg/s)

Laju Alir Dingin


(berubah) (Kg/s)

U Neraca Energi

U Empiris

13.5427408
3
11.7177144
0.964
0.654
1
12.5244563
0.964
1.1
8
12.3942033
0.964
0.876
9
13.9284152
0.964
0.608
4
13.0131112
0.964
0.704
3
a. Laju alir panas tetap dingin berubah RUN 1
0.964

8.52141683
8
8.40166301
7

0.696

Laju Alir Panas Tetap


(Kg/s)
1.348
1.348
1.348
1.348
1.348
1.348

Laju Alir Dingin (berubah)


(Kg/s)
1.1
0.986
1.116
1.204
1.248
1.244

9.89409833
9.03842495
7
8.60374195
8
8.52764660
8

Effisiensi (%)
27.85123967
38.45081136
0
-13.17178034
-40.50480769
-10.83601286

run 1
50
run 1
0
0.95

1.05 1.1 1.15 1.2 1.25 1.3

-50

b. Laju alir panas tetap dingin berubah RUN 2

Laju Alir Panas tetap


(Kg/s)

Laju Alir Dingin (berubah)


(Kg/s)

0.574
0.574
0.574
0.574
0.574
0.574

0.336
0.616
0.844
0.848
0.964
1.12

effisiensi (%)
39.42307692
9.318181818
3.579446246
3.981687014
3.721473029
80.92105263

run 2
100
run 2
50
0
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2

c. Laju alir dingin tetap panas berubah RUN 1


Laju Alir Dingin (tetap)
(Kg/s)
0.668
0.668
0.668
0.668
0.668
0.668

Laju Alir Panas berubah)


(Kg/s)
0.676
0.68
0.692
0.744
0.688
0.704

effisiensi (%)
17.44786289
6.786427146
24.86227545
37.1257485
28.08927599
35.12974052

run 3
40
30
20
10
0
0.67 0.68 0.69 0.7 0.71 0.72 0.73 0.74 0.75

run 3

d. Laju alir dingin tetap panas berubah RUN 1


Laju Alir Dingin (tetap)
(Kg/s)
0.964
0.964
0.964
0.964
0.964
0.964

Laju Alir Panas berubah)


(Kg/s)
0.696
0.654
1.1
0.876
0.608
0.704

effisiensi (%)
21.23505004
18.99585062
16.30112626
16.52206714
27.33056708
21.90871369

run 4
30
run 4

20
10
0
0.5

0.6

0.7

0.8

0.9

1.1

1.2

Vous aimerez peut-être aussi