Académique Documents
Professionnel Documents
Culture Documents
P.O Box 3422, Opp Gasoline Station, beside Al-kadi Tent factory, near King
Abdul-aziz Sea Port - Dammam 31471, Saudi Arabia.
Tel: +966-3-8475785-231 E-Mail: sales@tcr-arabia.com www.tcr-arabia.com
ULTRASONICTESTINGREPORT
Client:GeneralElectricity
Project:DhurumaO&MSTG10
ReferenceCode:ASMEVArticle4
Location: PP11Dhuruma,Riyadh
TestProcedure: QCP/TCR/UT/1.0REV.1
AcceptanceStandard:ASPERPROCEDURE
DateTested:October16 17,2015
ReportNo.:
Page: 1of1
INSPECTIONPARAMETERS
FlawDetector
ExaminationSystem
ScanningdB
+6dB
DefectReportLevel
DefectRejectLevel
Material
Bearing
Metal
AreaScanned
MODSONIC
AScan
ReferencedB
54dB
Asperprocedure
Range
100mm
Sensitivity
80%BWE
AccessibleArea
Model/SN
Calibrationblock
Couplant
ProbeAngle
ProbeType
TRProbe
TwinCrystal
SurfaceCondition
E34940912
StepWedge,V2Block
UltraGel
CrystalSize
Frequency
10mm
4MHz
Normal
TESTRESULTS
S.INo.
Description
1
TurbineEndThrustPadT2(Top)
2
TurbineEndThrustPadT3(Top)
3
TurbineEndThrustPadT4(Top)
4
TurbineEndThrustPadT5(Top)
5
TurbineEndThrustPadT6(Bottom)
6
TurbineEndThrustPadT7(Bottom)
7
TurbineEndThrustPadT8(Bottom)
8
TurbineEndThrustPadT1(Bottom)
9
TurbineSideTiltingPadT1B2
10
TurbineSideTiltingPadT1B3
11
TurbineSideTiltingPadT1B4
12
TurbineSideTiltingPadT1U1
13
TurbineSideTiltingPadT1U5
14
TurbineSideTiltingPadT1U9
15
GeneratorSideTiltingPadT2UR
16
GeneratorSideTiltingPadT2UC
17
GeneratorSideTiltingPadT2ULL
18
GeneratorSideTiltingPadT2BC
19
GeneratorSideTiltingPadT2BR
20
GeneratorSideTiltingPadT2BL
NOTE:NUA(NoUnbondedArea)
Observation
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
Result
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
ATTACHMENTS:Three(3)pagesofphotos.
Inspectedby:
Reviewedby:
RONELCUSTODIO
TCRARABIANDTLevelII
Date:October21,2015
TCRARABIANDTLevelIII
Date: