With clear specification of the protection function
requirements, a test procedure can be developed, which is
independent of the current realization and can be used for protection devices from multiple vendors. An example using test plan software can be seen in Figure 7. This template includes an XRIO converter with all necessary protection settings. All test modules are automated and are adapting to changed settings to support the test person. As the XRIO converter already holds the recommended default settings, the preparation time for the test is further minimized.