Vous êtes sur la page 1sur 1

(ADOBE READER FORMAT)

BINASTEEL INDUSTRIES SDN. BHD.


DURA M & S
To be also known as NOVA ISS, this pioneered composite stainless steel lined
sectional panel tank is a system-engineered combination of tank panels.
The tank panels are physically made of stainless steel material internally and
mild steel material externally. The external mild steel surface will be coated
in a layer of cold-galvaniser (variable colors) that is corrosion resistance.
This pioneered tank panel is widely accepted throughout the country
states and aiming to become a main stainless steel substition in the market.
Tested by SIRIM QAS International Sdn. Bhd. Result appeared to be positive.
(Report no.: 2006CB0105)

TECHNICAL SPECIFICATION
1. Design
1.1 Materials
The sectional panel tank shall consist of 4' x 4' or 1m x 1m panel manufactured
from 0.8mm thick stainless steel grade 304/316 plate with a 5mm thick welding
bonded backing mild steel plate (British standard BS:1564:1975).
The internal surface shall be stainless steel combined with external surface of
mild steel plate.

1.2 Flanges
The sectional panels shall be pressed to double flange at the angles of 45 and
90 degree to the face of the plate on four sides.

1.3 Reinforcement Method


The stainless steel lined sectional tank shall be constructed using external
reinforcement syste,. In assembly the tank, the flanges of the panels are
strengthened by galvanized reinforced channel and roof stay bolt.
The roof panels are supported by top panel support, which shall be made
from stainless steel angle and channel.
The tank is designed to rest and supported on reinforced concrete floor.

1.4 Manufacture
The composite panel consists of stainless steel plate and mild steel plate,
which shall be produced in one piece by moulding process that can provide
an impermeable and corrosion resistant characteristic.

2. Accessories
2.1 Bolt, nut & washer
i) Stainless steel 304/316 material shall be used wherein contact with water.
ii) Hot dipped galvanised mild steel material shall be used externally of the
tank.

2.2 Sealing material


Non-toxic P.V.C foam tape shall be used in between the jointings.

2.3 Covers
The tank cover shall be constructed by 1.2mm thick stainless steel grade 304/316
or 0.8mm stainless steel 304/316 composite with 1.5mm thick of mild steel plate
4' x 4' or 1m x 1m.

2.4 Ladders and Level Indicator


Internal ladder and external ladder shall be made of stainless steel grade
304/316 and aluminum material respectively.
Level indicator shall be hot-dipped galvanised c/w P.V.C ball float.