Phenomenon Description
ALARM HANDLING
Threshold Crossed is reported when the BTS detects that the antenna VSWR exceeds a specified
range for three consecutive times.
VSWR alarm thresholds have two levels: level 1 and level 2. You can run the MML command
SET BTSRXUBP to change the thresholds to meet the requirements for antenna VSWR
monitoring.
1. The default value of the level-1 VSWR threshold is 2.0. The minimum value of this
threshold is 1.8. The BTS considers this threshold as 1.8 even if it is set to a value less
than 1.8.
2. The default value of the level-2 VSWR threshold is 3.0. The value of this threshold must
be greater than the value of the level-1 VSWR threshold.
A minor alarm is reported when the BTS detects that the antenna VSWR is higher than the level1 VSWR threshold but lower than or equal to the level-2 VSWR threshold for three consecutive
times. A major alarm is reported when the BTS detects that the antenna VSWR is higher than the
level-2 VSWR threshold for three consecutive times.
The alarm clearance conditions are as follows:
A minor alarm is cleared when the BTS detects that the antenna VSWR is lower than the
level-1 VSWR threshold for three consecutive times.
A major alarm is cleared when the TRX is reset while a normal antenna VSWR is
ensured.
Parameters
Name
Meaning
Cabinet No.
Subrack No.
Slot No.
TX Channel No.
TX channel number
Board Type
VSWR
Alarm Severity
Minor
System Actions
The BTS does not process a minor alarm. A minor alarm is automatically cleared when the
detected VSWR is smaller than the level-1 VSWR threshold.
When the BTS detects a major alarm, it closes the transmit channel. A major alarm cannot be
automatically cleared.
Possible Causes
Hardware fault
The frequency band type of the TRX is inconsistent with that of the antenna components.
The actual VSWR of the antenna components increases, leading to an abnormal antenna VSWR.
The reason may be:
1. An antenna component is damaged.
2. A connector on an antenna component is not well prepared.
3. A connector on an antenna component is not tightened or is wet.
4. An antenna cable is bent or deformed.
The two input ports on the 3 dB combiner or hybrider are not highly isolated. Therefore, the
detected VSWR is higher than the actual VSWR, which leads to false VSWR alarms. This
situation occurs when a combiner is used by multiple carriers working on the same frequency
band.
NOTE:
The antenna system usually has the following components: antenna, feeder, jumper, combiner
and splitter, 3 dB hybrider, directional coupler, filter, tower-mounted amplifier (TMA), and BIAS
TEE.
A transmit port on the RF unit is damaged.
The VSWR detection circuit of the RF unit is faulty.
Troubleshooting
To check whether the antenna system is faulty, use a new antenna to replace the antenna
connected to the TRX reporting this alarm.
Workflow
Procedure
1. Check the VSWR alarm thresholds remotely.
a. Run the MML command LST BTSRXUBP to query the VSWR thresholds for
the RF unit and determine whether the thresholds are set correctly according to
the configuration plan.
Y => The thresholds are set correctly. Go to step 2.
N => The thresholds are set incorrectly. Go to step b.
b. Run the MML command SET BTSRXUBP to modify the VSWR thresholds for
the RF unit.
If the alarm is a major alarm, reset the TRX. Ten minutes later, check whether the alarm is
cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 2.
2. Reset the TRX remotely.
On the LMT, reset the TRX where the alarm is generated. Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 3.
3. Check the frequency band used by the RF unit and antenna components.
a. Check whether the frequency band type of the RF unit is consistent with that used
by the antenna components.
Y => The frequency band types are consistent. Go to step 4.
N => The frequency band types are inconsistent. Go to step b.
b. Replace the antenna components with new ones that work on the same frequency
band as the old components.
If the alarm is a major alarm, reset the TRX. Ten minutes later, check whether the alarm is
cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 4.
4. CAUTION:
5. The check personnel must carry antenna components with the same frequency band type
as that of the RF unit when checking VSWR faults at sites.
6. Check the antenna VSWR.
a. Check the antenna VSWR as follows: If there is a VSWR tester, test the VSWR at
the antenna ports in frequency mode. If there is no VSWR tester, replace the
antenna to check whether the antenna system is faulty.
Check whether the alarm is cleared.
Y => The antenna VSWR is normal. Go to step 5.
N => The antenna VSWR is abnormal. Go to step b.
b. Rectify the VSWR faults in the antenna system as follows: If there is a VSWR
tester, check for antenna faults in distance to fault (DTF) mode and rectify the
faults. If there is no VSWR tester, check for antenna faults by checking whether
the connectors on the antenna components are tightened, whether the antenna
components are damaged, or by replacing the antenna components, and then
rectify the faults.
If the alarm is a major alarm, reset the TRX. Ten minutes later, check whether the alarm is
cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 5.
7. Check whether a combiner is used.
a. Check whether a combiner is used for multiple carriers.
Y => A combiner is used. Go to step b.
N => A combiner is not used. Go to step 6.
b. Replace the existing combiner with a new combiner whose input ports are highly
isolated.
If the alarm is a major alarm, reset the TRX. Ten minutes later, check whether the alarm is
cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 6.
8. Reset the RF unit on site.
a. Power off and then power on the RF unit. After the RF unit restarts, the RUN
indicator blinks one second on and one second off if the RF unit works properly.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Go to step 7.
9. Replace the RF unit on site.
a. Replace the RF unit.
Check whether the alarm is cleared.
Y => The alarm is cleared. No further action is required.
N => The alarm persists. Reinstall the original board and contact Huawei customer service
center.
Resolving Action
Check VSWR at Jumper cable , Combiner and DAS with site master. It is found that
the problem source is the multiband combiner. After replacing the faulty ony, VSWR
back to normal.
Status After